Professional Documents
Culture Documents
Subject: City of Satellite Beach Per– and Polyfluoroalkyl Substances (PFAS) Water
Sampling
Satellite Beach, Florida
Tetra Tech, Inc. (Tetra Tech) is pleased to provide the City of Satellite Beach this report
summarizing the recent Per– and Polyfluoroalkyl Substances (PFAS) groundwater sampling
services for the City of Satellite Beach.
BACKGROUND
PFAS are a group of manufactured compounds widely used to make products resistant to stains,
grease, and water. These compounds are found in everyday products, such as nonstick pans, post
it notes, and food packaging. PFAS are also widely used in fire suppression foams. Some PFAS
compounds can biotransform to perfluoroalkyl acids like perfluorooctane sulfonate (PFOS) and
perfluorooctanoic acid (PFOA), which do not readily degrade. These compounds are emerging
contaminants, and the science of the health risks, fate and transport, and detection methods is
developing but still in the initial stages.
The most likely route of exposure to these chemicals is through contaminated food or water. The
United States Environmental Protection Agency (USEPA) has not established maximum
contaminant levels (MCLs) for drinking water for PFAS, and the Florida Department of
Environmental Protection (DEP) has not established Groundwater Cleanup Target Levels for
PFAS. However, the USEPA has established a Health Advisory for PFOA and PFOS of 0.07
ug/L, and the DEP is expected to release its health advisory levels in the coming days.
The City of Satellite Beach requested that Tetra Tech install and sample three monitoring wells.
The City selected two City owned properties and one Brevard County owned property for the
installation and sampling of monitoring wells with analysis for PFAS compounds, including
PFOA and PFOS.
PHYSICAL SETTING
According to the Geologic Map of Florida (Florida Geologic Survey 2001) the City of Satellite
Beach is located in the Pleistocene/Holocene aged Beach Ridge and Dune Formation. The
formation includes siliciclastics of light gray, tan, brown to black, unconsolidated to poorly
consolidated, clean to clayey, silty, unfossiliferous, variably organic-bearing sands to blue green
to olive green, poorly to moderately consolidated, sandy, silty clays. The sandy marine deposits
are underlain by limestone, which may be exposed along much of the shoreline of Satellite
Beach.
Tetra Tech initiated field activities on July 17, 2018. The investigation included the installation
and sampling of three monitoring wells at the following locations, as shown on Figure 1:
Prior to drilling, Sunshine One Call underground utility clearance hotline was contacted by Tetra
Tech’s Licensed Well Drilling subcontractor, Preferred Drilling Solutions, Inc., to mark publicly
accessible utilities. Well Construction Permits were obtained from the Brevard County Health
Department prior to drilling, and permits are provided in Attachment A.
All borings were hand cleared with a 4-inch diameter hand auger to identify and minimize the
likelihood of damage to shallow subgrade utilities. Three groundwater monitoring wells were
installed. Each well was constructed with a 1-inch diameter, Schedule 40, polyvinyl chloride
(PVC), 0.010-inch slotted well screen, and 20-30 size sand filter pack. The well screens at each
well location were 10 feet long. Drilling activities encountered refusal at a depth of 12.5 feet below
ground surface (bgs) at location SB1, likely due to the presence of limestone, and well screens were
installed from 2.2 to 12.2 feet bgs. Monitoring wells SB2 and SB3 were installed to a depth of 19.5
feet bgs, with well screen installed between 9.5 and 19.5 feet bgs. Sand filter pack was installed to
one foot above the well screen. A minimum of 6-inches of bentonite was placed above the sand
pack, and neat portland cement was used to seal the well to the surface. After installation and
development, each temporary monitoring well was allowed to stabilize for a minimum of 24 hours
TETRA TECH
Mr. Nick Sanzone
August 2, 2018
Page 3 of 10
before purging and sampling was initiated. The Well Construction and Development Logs are
provided in Attachment A.
Each of the three monitoring wells were purged and sampled with a peristaltic pump using the low
flow sampling techniques. Purging and groundwater sample collection was conducted in general
accordance with FDEP-SOP-001/01 FS 2200: Groundwater Sampling, with additional
precautions for PFAS cross contamination using Tetra Tech Standard Operating Procedure SA-
1.8 for Sample Acquisition for Perfluoroalkyl and Perfluoroalkyl Substances (PFAS) Analysis.
New High-Density Poly Ethylene (HDPE) tubing was used to purge and collect groundwater
samples at each monitoring well. Samples were obtained by pumping water from the aquifer
until the water quality parameters stabilize. Field parameters (pH, specific conductance,
dissolved oxygen, temperature, and turbidity) were measured at regular intervals using a water
meter equipped with a flow through cell until three consecutive measurements met the following
thresholds:
• Temperature: ± 0.2° C
• pH: ± 0.2 Standard Units
• Specific Conductance: ± 5.0% of reading
• Dissolved Oxygen: ≤20% Saturation
• Turbidity: ≤20 NTU
In addition to the monitoring well samples, one Field Reagent Blank was also collected prior to
sampling SB3. Samples were placed in laboratory-provided containers, sealed, labeled, packed
in ice, and shipped under chain-of-custody protocol to SGS Laboratories for analysis of PFAS,
including PFOA, PFOS and 22 additional compounds via USEPA Method 537M.
Tetra Tech compared the analytical results of the groundwater samples to the 0.070 ug/L USEPA
Health Advisory, as outlined in the USEPA documents Drinking Water Health Advisory for
Perfluorooctanoic Acid (PFOA) (USEPA May 2016) and Drinking Water Health Advisory for
Perfluorooctane Sulfonate (PFOS) (USEPA May 2016). In the USEPA Memorandum dated
November 15, 2016, USEPA provided clarification that the purpose of the Health Advisories
was to “identify the concentration of PFOA and PFOS in drinking water at which adverse health
effects are not anticipated to occur over a lifetime.” The health advisories are not intended to be
TETRA TECH
Mr. Nick Sanzone
August 2, 2018
Page 4 of 10
used for other exposure scenarios. The State of Florida DEP does not currently have a
Groundwater Cleanup Target Level for PFOA and PFOS; however, DEP has stated that they will
be issuing a Health Advisory Level for PFOA and PFOS in the coming days.
PFOA and PFOS were detected in each of the three monitoring wells, with PFOA concentrations
ranging from 0.00733 ug/L I (I qualified, meaning that the detected concentration was below the
practical quantitation limit) in SB3 to 0.0119 ug/L in SB1. PFOS concentrations ranged from
0.0188 ug/L in SB2 to 0.0296 ug/L in SB1. USEPA recommends adding PFOA and PFOS
numbers together if both compounds are present and applying the sum of both compounds to the
0.070 ug/L Health Advisory Level. Combined PFOS and PFOA concentrations ranged from
0.02285 ug/L in SB2 to 0.0415 ug/L in SB1. All the PFOA and PFOS (including combined)
results were less than the 0.070 ug/L USEPA Health Advisory Level.
In addition to PFOA and PFOS, other PFAS were detected; however, there are no USEPA
Health Advisory Levels available for PFAS except for PFOA and PFOS. The following
additional PFAS compounds were detected:
An analytical data summary and comparison to the USEPA Health Advisories is provided in
Table 1, a summary of the PFOA and PFOS results are provided on Figure 1, and the laboratory
analytical report is provided in Attachment C.
CONCLUSIONS
Based on the results of the groundwater sampling and analytical results, PFAS analytes were
detected in each of the three monitoring wells, and PFOA and PFOS were both detected in each
of the three wells. The individual PFOA and PFOS concentrations and the sum of the PFOA and
PFOS concentrations were less than the USEPA Health Advisory level of 0.070 ug/L for each
TETRA TECH
Figures
TETRA TECH
Tables
TETRA TECH
Table 1 - Monitroing Well PFAS Analytical Results
City of Satellite Beach
Notes:
All results are reported in ug/L.
USEPA HA - United States Environmental Protection Agency Health Advisory Level.
a - Associated CCV outside of control limits high, sample was ND.
U - Not detcted above the referenced method detection limit.
I - Result concentration is greater than or equal to the method detection limit but less than the practical quantitation limit.
NA - Not available.
Attachment A
TETRA TECH
Attachment B
TETRA TECH
Attachment C
TETRA TECH
07/31/18
Orlando, FL 07/31/18
The results set forth herein are provided by SGS North America Inc.
e-Hardcopy 2.0
Automated Report
Tetra Tech
Satellite Beach PFC
100-1WM-T38598
SGS Job Number: FA55955
Report to:
Tetra Tech
11 Riverside Dr Suite 204
Cocoa, FL 32922
matt.shelton@tetratech.com
ATTN: Matt Shelton
Test results contained within this data package meet the requirements Caitlin Brice, M.S.
of the National Environmental Laboratory Accreditation Program General Manager
and/or state specific certification programs as applicable.
SGS North America Inc. • 4405 Vineland Road • Suite C-15 • Orlando, FL 32811 • tel: 407-425-6700 • fax: 407-425-0707
SGS is the sole authority for authorizing edits or modifications to this document. Please share your ideas about 1 of 26
Unauthorized modification of this report is strictly prohibited. how we can serve you better at:
Review standard terms at: http://www.sgs.com/en/terms-and-conditions EHS.US.CustomerCare@sgs.com FA55955
Sections:
Table of Contents
1
-1-
2
Section 1: Sample Summary ................................................................................................... 3
Section 2: Case Narrative/Conformance Summary .............................................................. 4
3
Section 3: Summary of Hits .................................................................................................... 5
Section 4: Sample Results ........................................................................................................ 6
4
4.1: FA55955-1: SB1-20180718 .......................................................................................... 7
4.2: FA55955-2: SB2-20180718 .......................................................................................... 9
5
4.3: FA55955-3: FRB-20180718 ......................................................................................... 11
4.4: FA55955-4: SB3-20180718 .......................................................................................... 13
6
Section 5: Misc. Forms ............................................................................................................ 15
5.1: Chain of Custody ........................................................................................................... 16
Section 6: MS Semi-volatiles - QC Data Summaries ............................................................ 18
6.1: Method Blank Summary ................................................................................................ 19
6.2: Blank Spike Summary ................................................................................................... 21
6.3: Matrix Spike Summary .................................................................................................. 23
6.4: Duplicate Summary ....................................................................................................... 25
2 of 26
FA55955
1
SGS North America Inc.
Sample Summary
Tetra Tech
Job No: FA55955
Satellite Beach PFC
Project No: 100-1WM-T38598
3 of 26
FA55955
SAMPLE DELIVERY GROUP CASE NARRATIVE
2
Client: Tetra Tech Job No: FA55955
SGS Orlando certifies that this report meets the project requirements for analytical data produced for the samples as received at
SGS Orlando and as stated on the COC. SGS Orlando certifies that the data meets the Data Quality Objectives for precision, accuracy and
completeness as specified in the SGS Orlando Quality Manual except as noted above. This report is to be used in its entirety. SGS Orlando
is not responsible for any assumptions of data quality if partial data packages are used.
______________________________________
Kim Benham, Client Services (signature on file)
4 of 26
FA55955
Summary of Hits Page 1 of 1
Job Number: FA55955
Account: Tetra Tech
Project: Satellite Beach PFC
Collected: 07/18/18
3
Lab Sample ID Client Sample ID Result/
Analyte Qual PQL MDL Units Method
FA55955-1 SB1-20180718
FA55955-2 SB2-20180718
FA55955-3 FRB-20180718
FA55955-4 SB3-20180718
5 of 26
FA55955
SGS North America Inc.
Orlando, FL
Section 4
4
Sample Results
Report of Analysis
6 of 26
FA55955
SGS North America Inc.
4.1
Lab Sample ID: FA55955-1 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
PERFLUOROALKYLCARBOXYLIC ACIDS
375-22-4 Perfluorobutanoic acid 0.0101 0.015 0.0038 ug/l I
2706-90-3 Perfluoropentanoic acid 0.00721 0.0077 0.0029 ug/l I
307-24-4 Perfluorohexanoic acid 0.00614 0.0077 0.0019 ug/l I
375-85-9 Perfluoroheptanoic acid 0.00402 0.0077 0.0019 ug/l I
335-67-1 Perfluorooctanoic acid 0.0119 0.0077 0.0019 ug/l
375-95-1 Perfluorononanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-76-2 Perfluorodecanoic acid 0.0019 U 0.0077 0.0019 ug/l
2058-94-8 Perfluoroundecanoic acid 0.0019 U 0.0077 0.0019 ug/l
307-55-1 Perfluorododecanoic acid 0.0029 U 0.0077 0.0029 ug/l
72629-94-8 Perfluorotridecanoic acid 0.0019 U 0.0077 0.0019 ug/l
376-06-7 Perfluorotetradecanoic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROALKYLSULFONATES
375-73-5 Perfluorobutanesulfonic acid 0.0108 0.0077 0.0019 ug/l
2706-91-4 Perfluoropentanesulfonic acid 0.00552 0.0077 0.0019 ug/l I
355-46-4 Perfluorohexanesulfonic acid 0.0146 0.0077 0.0019 ug/l
375-92-8 Perfluoroheptanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
1763-23-1 Perfluorooctanesulfonic acid 0.0296 0.0077 0.0029 ug/l
68259-12-1 Perfluorononanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
335-77-3 Perfluorodecanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDES
754-91-6 PFOSA 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDOACETIC ACIDS
2355-31-9 MeFOSAA 0.0077 U 0.038 0.0077 ug/l
2991-50-6 EtFOSAA 0.0077 U 0.038 0.0077 ug/l
FLUOROTELOMER SULFONATES
757124-72-4 4:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
27619-97-2 6:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
7 of 26
FA55955
SGS North America Inc.
4.1
Lab Sample ID: FA55955-1 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
8 of 26
FA55955
SGS North America Inc.
4.2
Lab Sample ID: FA55955-2 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
PERFLUOROALKYLCARBOXYLIC ACIDS
375-22-4 Perfluorobutanoic acid 0.0038 U 0.015 0.0038 ug/l
2706-90-3 Perfluoropentanoic acid 0.00295 0.0077 0.0029 ug/l I
307-24-4 Perfluorohexanoic acid 0.0019 U 0.0077 0.0019 ug/l
375-85-9 Perfluoroheptanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-67-1 Perfluorooctanoic acid 0.00405 0.0077 0.0019 ug/l I
375-95-1 Perfluorononanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-76-2 Perfluorodecanoic acid 0.0019 U 0.0077 0.0019 ug/l
2058-94-8 Perfluoroundecanoic acid 0.0019 U 0.0077 0.0019 ug/l
307-55-1 Perfluorododecanoic acid 0.0029 U 0.0077 0.0029 ug/l
72629-94-8 Perfluorotridecanoic acid 0.0019 U 0.0077 0.0019 ug/l
376-06-7 Perfluorotetradecanoic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROALKYLSULFONATES
375-73-5 Perfluorobutanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
2706-91-4 Perfluoropentanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
355-46-4 Perfluorohexanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
375-92-8 Perfluoroheptanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
1763-23-1 Perfluorooctanesulfonic acid 0.0188 0.0077 0.0029 ug/l
68259-12-1 Perfluorononanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
335-77-3 Perfluorodecanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDES
754-91-6 PFOSA 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDOACETIC ACIDS
2355-31-9 MeFOSAA a 0.0077 U 0.038 0.0077 ug/l
2991-50-6 EtFOSAA 0.0077 U 0.038 0.0077 ug/l
FLUOROTELOMER SULFONATES
757124-72-4 4:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
27619-97-2 6:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
9 of 26
FA55955
SGS North America Inc.
4.2
Lab Sample ID: FA55955-2 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
(a) Associated CCV outside of control limits high, sample was ND.
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
10 of 26
FA55955
SGS North America Inc.
4.3
Lab Sample ID: FA55955-3 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
PERFLUOROALKYLCARBOXYLIC ACIDS
375-22-4 Perfluorobutanoic acid 0.0038 U 0.015 0.0038 ug/l
2706-90-3 Perfluoropentanoic acid 0.0029 U 0.0077 0.0029 ug/l
307-24-4 Perfluorohexanoic acid 0.0019 U 0.0077 0.0019 ug/l
375-85-9 Perfluoroheptanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-67-1 Perfluorooctanoic acid 0.0019 U 0.0077 0.0019 ug/l
375-95-1 Perfluorononanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-76-2 Perfluorodecanoic acid 0.0019 U 0.0077 0.0019 ug/l
2058-94-8 Perfluoroundecanoic acid 0.0019 U 0.0077 0.0019 ug/l
307-55-1 Perfluorododecanoic acid 0.0029 U 0.0077 0.0029 ug/l
72629-94-8 Perfluorotridecanoic acid 0.0019 U 0.0077 0.0019 ug/l
376-06-7 Perfluorotetradecanoic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROALKYLSULFONATES
375-73-5 Perfluorobutanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
2706-91-4 Perfluoropentanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
355-46-4 Perfluorohexanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
375-92-8 Perfluoroheptanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
1763-23-1 Perfluorooctanesulfonic acid 0.0029 U 0.0077 0.0029 ug/l
68259-12-1 Perfluorononanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
335-77-3 Perfluorodecanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDES
754-91-6 PFOSA 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDOACETIC ACIDS
2355-31-9 MeFOSAA a 0.0077 U 0.038 0.0077 ug/l
2991-50-6 EtFOSAA 0.0077 U 0.038 0.0077 ug/l
FLUOROTELOMER SULFONATES
757124-72-4 4:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
27619-97-2 6:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
11 of 26
FA55955
SGS North America Inc.
4.3
Lab Sample ID: FA55955-3 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
(a) Associated CCV outside of control limits high, sample was ND.
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
12 of 26
FA55955
SGS North America Inc.
4.4
Lab Sample ID: FA55955-4 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
PERFLUOROALKYLCARBOXYLIC ACIDS
375-22-4 Perfluorobutanoic acid 0.00631 0.015 0.0038 ug/l I
2706-90-3 Perfluoropentanoic acid 0.0129 0.0077 0.0029 ug/l
307-24-4 Perfluorohexanoic acid 0.00625 0.0077 0.0019 ug/l I
375-85-9 Perfluoroheptanoic acid 0.00288 0.0077 0.0019 ug/l I
335-67-1 Perfluorooctanoic acid 0.00733 0.0077 0.0019 ug/l I
375-95-1 Perfluorononanoic acid 0.0019 U 0.0077 0.0019 ug/l
335-76-2 Perfluorodecanoic acid 0.0019 U 0.0077 0.0019 ug/l
2058-94-8 Perfluoroundecanoic acid 0.0019 U 0.0077 0.0019 ug/l
307-55-1 Perfluorododecanoic acid 0.0029 U 0.0077 0.0029 ug/l
72629-94-8 Perfluorotridecanoic acid 0.0019 U 0.0077 0.0019 ug/l
376-06-7 Perfluorotetradecanoic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROALKYLSULFONATES
375-73-5 Perfluorobutanesulfonic acid 0.00615 0.0077 0.0019 ug/l I
2706-91-4 Perfluoropentanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
355-46-4 Perfluorohexanesulfonic acid 0.00207 0.0077 0.0019 ug/l I
375-92-8 Perfluoroheptanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
1763-23-1 Perfluorooctanesulfonic acid 0.0228 0.0077 0.0029 ug/l
68259-12-1 Perfluorononanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
335-77-3 Perfluorodecanesulfonic acid 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDES
754-91-6 PFOSA 0.0019 U 0.0077 0.0019 ug/l
PERFLUOROOCTANESULFONAMIDOACETIC ACIDS
2355-31-9 MeFOSAA 0.0077 U 0.038 0.0077 ug/l
2991-50-6 EtFOSAA 0.0077 U 0.038 0.0077 ug/l
FLUOROTELOMER SULFONATES
757124-72-4 4:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
27619-97-2 6:2 Fluorotelomer sulfonate 0.0038 U 0.015 0.0038 ug/l
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
13 of 26
FA55955
SGS North America Inc.
4.4
Lab Sample ID: FA55955-4 Date Sampled: 07/18/18
Matrix: AQ - Ground Water Date Received: 07/19/18
Method: EPA 537M BY ID EPA 537 MOD Percent Solids: n/a
4
Project: Satellite Beach PFC
PFAS List
U = Not detected MDL = Method Detection Limit I = Result >= MDL but < PQL J = Estimated value
PQL = Practical Quantitation Limit V = Indicates analyte found in associated method blank
L = Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound
14 of 26
FA55955
SGS North America Inc.
Orlando, FL
Section 5
Misc. Forms
5
Custody Documents and Other Forms
15 of 26
FA55955
55.1
FA55955: Chain of Custody
Page 1 of 2
16 of 26
FA55955
SGS Sample Receipt Summary
Job Number: FA55955 Client: TERATECH Project: SATELLITE BEACH PFC
Date / Time Received: 7/19/2018 3:05:00 PM Delivery Method: ALSE Airbill #'s:
5.1
2. Custody Seals Intact 2. Samples preserved properly
3. Temp criteria achieved 3. Sufficient volume/containers recvd for analysis:
4. Cooler temp verification IR Gun 4. Condition of sample Intact
5
5. Cooler media Ice (Bag) 5. Sample recvd within HT
6. Dates/Times/IDs on COC match Sample Label
Trip Blank Information Y or N N/A 7. VOCs have headspace
1. Trip Blank present / cooler 8. Bottles received for unspecified tests
2. Trip Blank listed on COC 9. Compositing instructions clear
10. Voa Soil Kits/Jars received past 48hrs?
W or S N/A
11. % Solids Jar received?
3. Type Of TB Received
12. Residual Chlorine Present?
Misc. Information
Number of Encores: 25-Gram 5-Gram Number of 5035 Field Kits: Number of Lab Filtered Metals:
Test Strip Lot #s: pH 0-3 230315 pH 10-12 219813A Other: (Specify)
Residual Chlorine Test Strip Lot #:
Comments
SM001
Rev. Date 05/24/17 Technician: PETERH Date: 7/19/2018 3:05:00 PM Reviewer: Date:
17 of 26
FA55955
SGS North America Inc.
Orlando, FL
Section 6
MS Semi-volatiles
6
QC Data Summaries
18 of 26
FA55955
Method Blank Summary Page 1 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.1.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
19 of 26
FA55955
Method Blank Summary Page 2 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.1.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
20 of 26
FA55955
Blank Spike Summary Page 1 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.2.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
21 of 26
FA55955
Blank Spike Summary Page 2 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.2.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
22 of 26
FA55955
Matrix Spike Summary Page 1 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.3.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
FA55955-3 Spike MS MS
CAS No. Compound ug/l Q ug/l ug/l % Limits
23 of 26
FA55955
Matrix Spike Summary Page 2 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.3.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
24 of 26
FA55955
Duplicate Summary Page 1 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.4.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
FA55955-4 DUP
CAS No. Compound ug/l Q ug/l Q RPD Limits
25 of 26
FA55955
Duplicate Summary Page 2 of 2
Job Number: FA55955
Account: TETRFLC Tetra Tech
Project: Satellite Beach PFC
6.4.1
The QC reported here applies to the following samples: Method: EPA 537M BY ID
6
FA55955-1, FA55955-2, FA55955-3, FA55955-4
26 of 26
FA55955