Professional Documents
Culture Documents
CLSACC
No. of TRXs 10% 15% 20% 25% 30% 35% 40%
1 (7 TCHs) 0 1 1 1 2 2 2
2 (14 TCHs) 1 2 2 3 4 4 5
3 (21 TCHs) 2 3 4 5 6 7 8
4 (28 TCHs) 2 4 5 7 8 9 11
5 (36 TCHs) 3 5 7 9 10 12 14
The object type CELEVENTH contains counters related to the Cell Load Sharing feature. See Reference [4] for deta
CLSTIME Accumulated time in seconds when Cell Load Sharing evaluation is performed in the ce
TOTCLSTIME Total time for the Cell Load Sharing feature being active in seconds.
Table 3
Recomm
Parameter Default Value
ended Unit
name value range
value
CLSLEVEL 20 - 0 to 99 %
CLSACC 40 - 1 to 100 %
CLSRAMP 5 8 0 to 30 s
HOCLSACC OFF ON ON, OFF
RHYST 75 100 0 to 100 %
CLSTIMEIN 100 to
100 100 ms
TERVAL 1000
EBANDINCL
OFF - ON, OFF
UDED
GPRSPRIO is a cell parameter that controls whether on-demand PDCHs shall be treated as idle or busy when calcu
CLSLEVEL defines a percentage of idle TCHs, at or below which the ranking recalculations are started. The para
CLSACC defines a percentage of idle TCHs, at or below which no handovers due to cell load sharing are accepte
RHYST is the hysteresis reduction parameter. It defines the final reduction of the hysteresis area as a percenta
e Reference [4] for details.
idle or busy when calculating the percentage of idle channels (see the entire parameter description in Reference [1].
s are started. The parameter is defined as a percentage of the total number of available TCHs in the cell. It is defined per
ad sharing are accepted. The parameter is defined as a percentage of the total number of available TCHs in the cell. The v
ble TCHs in the cell. The value of CLSACC shall be greater than that of CLSLEVEL . CLSACC is defined per cell.
Figure 2 Actual Cell Border After Hysteresis Reduction
Certain additional conditions must be fulfilled for a Cell Load Sharing handover
Locating conditions:
Cell Load Sharing handover is not allowed during the assignment procedu
Cell Load Sharing handover is not allowed if there is an urgency condition, s