Occupancy Sensors

meets energy codes • supports sustainable designs


• saves energy
The NEW generation of
occupancy sensors:
Watt Stopper/Legrand’s new generation of
occupancy sensors are packed with features
and options that streamline sensor installation
and strengthen performance - yet fit in a small,
clean package.

Low profile
design Attractive new enclosures offer a flat,
extremely low profile appearance that
leaves the ceiling clean and
uncluttered.

360°
coverage With a full 360° of coverage, these
sensors are able to control a wide
range of applications, either
individually, or for large areas, in
zones that overlap.

SmartSet™
technology
Watt Stopper SmartSet technology means no
adjustments are needed at installation.
SmartSet monitors the space to identify usage
patterns. With this information, it automatically

Walk-
adjusts the time delay and sensitivity settings
for both optimal performance and maximum

through mode
energy efficiency.

The lights don’t need to stay on for the entire


length of the time delay if someone is just
dropping off mail or other items. With our
smart Walk Through Mode, lights turn off 3
minutes after an area is initially occupied if
no movement is detected within 30 seconds.
Quick
terminal wiring
Terminal wiring and depluggable terminal
wiring are featured throughout our new
generation of occupancy sensors. Quick and
easy installations are now the new standard.

Low & line voltages Low voltage sensors are well suited in most
applications. The simplicity of low voltage wiring
allows for optimal placement. However, some
applications, because of installer preference, are
better suited to line voltage ceiling mount sensors.
Our new generation of sensors are available in both
line and low voltage models to match each and
every application and installation style.

Diffusers
Both the ultrasonic and dual technology
sensors benefit from the new Ultrasonic
Diffusers. The diffusers are able to evenly
distribute the ultrasound in order to achieve
a more comprehensive coverage of the
controlled area.

One touch
light level
Many occupancy sensors contain a built-in
light level sensor. Our new generation
sensors incorporate this feature PLUS a
unique one-touch set up.

Manual
operation
When the application calls for manual on/off control
in addition to the occupancy based control, the new
generation sensors do the job. They offer the
convenience of a low voltage switch input (on the low
voltage sensor models) so that wiring to a
momentary wall switch is quick and easy.
Occupancy sensor technologies

Passive infrared
ceiling mount sensors
Many Watt Stopper PIR sensors
are enhanced with advanced Passive infrared technology (PIR)
technologies to ensure higher
sensitivity to minor motion PIR technology senses occupancy by detecting the
without the potential for false
difference between heat emitted from the human body in
activations. These include
Detection Signature Analysis motion and the background space.
and Pulse Count Processing.
Relying on a clear line-of-sight view, passive infrared
WPIR
sensors make 100% coverage cut off possible. These
CX series
sensors utilize a unique Fresnel lens which divides the
CI-200 series
coverage area into zones, enhancing detection of small
CI-300 series
movement.
CB-100

Wall switch technologies


Watt Stopper automatic wall
switches incorporate features, such
as Zero Crossing, that increase the switch’s life and enhances
reliability. They also offer features such as terminal style wiring,
which simplifies installation, and SmartSet technology, which
automatically adjusts time delays and sensitivity based on usage
patterns.

WS-200 WN-100-120/277
WA-200, WA-300 WD series
3 800.879.8585 • www.wattstopper.com WI-200, WI-300
Ultrasonic technology

Using the Doppler principle, ultrasonic sensors work


by bouncing ultrasonic sound waves off objects in an
area and measuring the time it takes for the waves to
return. Movement by a person in the area causes the
sound waves to return at a changed frequency,
resulting in a Doppler shift and occupancy detection.

Ultrasonic technology
These sensors utilize our Advanced Signal Processing Circuitry to
automatically adjust the signal detection threshold in
compensation for changing levels of activity and airflow. This
helps eliminate false ON activations common in other ultrasonic
sensors.

W series
WT series
UT-300 series

Dual technology

While PIR and ultrasonic sensors provide


optimal control for a variety of spaces, Dual technology
some applications pose difficulty for single
technology sensors. Dual Technology sensors
ensure the greatest sensitivity
and coverage for tough
We created and patented Dual Technology – a applications, without the threat
combination that takes advantage of the best of false triggers. This leads to
features of both PIR and ultrasonic technologies. the greatest energy savings.
Using the Dual Sensing Verification Principle, both
DT-200 series
technologies must detect occupancy to turn
DT-300 series
lighting on, while continued detection by only one
technology will hold lighting on.
800.879.8585 • www.wattstopper.com 4
Applying occupancy sensors

In offices where the wall


switch has a view of the work
space, replace the switch with
a passive infrared wall switch
sensor. Take advantage of the
built-in light level feature to
keep lights off when ample
sunlight is present.

Control lighting in restrooms with


ultrasonic sensors and eliminate
hours of unneeded on-time.
Ceiling-mounted ultrasonics can
sense motion around restroom
stalls for reliable coverage.

In open or partitioned offices,


use ultrasonic or dual
technology sensors. Placed on
the ceiling, these sensors
cover the area in zones that
overlap.

PIR PIR Wall Switch


Best Applications Best Applications
• Warehouses • Offices
• High ceiling mount locations • Copy rooms and other common
• Library bookstack or other aisles building areas
• Common building areas • Storage closets
• Lobbies • Small conference rooms
• Computer rooms

5 800.879.8585 • www.wattstopper.com
Common building spaces, such as
copy rooms, are ideal for
occupancy based control. With a
passive infrared sensor placed in
the corner of the ceiling or as a
wall switch replacement, users
can save hours of wasted lighting
each day.

In large conference
rooms, occupants may be
still for long periods of time.
Dual technology sensors will
be able to detect the small motion
and keep lights on as long as the
space is occupied.

Use occupancy sensors


together with other control
methods such as lighting
control panels or daylighting
controls. Integrating control
options can help you meet
energy codes and sustainability
guidelines as well as maximize
energy savings.

In warehouses, a passive
infrared sensor mounted to
a ceiling or fixture will
control the lighting
between shelves – so that
lighting in unoccupied areas
will turn off or turn to a lower
level. Users can achieve this
control with fluorescent as well
as HID lighting.

Ultrasonic Dual Technology


Best Applications Best Applications
• Restrooms • Classrooms
• Open office spaces • Large conference rooms
• Offices • Large offices
• Enclosed hallways • Lunch rooms
• Stairways

800.879.8585 • www.wattstopper.com 6
WS-200 Automatic Wall Switch

Attractive, low-profile appearance Adjustable sensitivity

Built-in light level sensor Zero Crossing Circuitry increases longevity

Terminal style wiring for easy installation ASIC technology

Specifications Applications
• Dual 120/277 voltage • Compatible with all electronic • Small offices
• 30 sec to 30 min time delay ballasts and PL lamp ballasts • Small conference rooms
• Built-in light level sensor 2 to 200 • 2.6” x 1.7” x 2” L x W x D • Break rooms
fc (107 to 1,614 lux) (66.0mm x 44.2mm x 50.8mm) • Utility rooms
• No minimum load requirement • UL and CUL listed, 5 year warranty • Storage closets

Wiring Diagram Coverage Pattern

The WS-200 can be Neutral Coverage shown is


wired for single-level for half-step, walking
lighting (shown), or motion, maximum of
for manual bi-level Load
900 sq ft. For typical,
control. Load Line
desktop activity,
35'
(10.7m)
when mounted at 4 ft
(1.2m), coverage is
Ground 300 ft2 (27.9 m2).

15'
(4.6m)

Order Information
CATALOG # VOLTAGE* LOAD REQUIREMENTS COVERAGE*
WS-200 120 VAC; 60 Hz or 0-800 Watt Ballast or up to 900 ft2 (83.6 m2), 180°
277 VAC; 60 Hz 0-1200 Watt Ballast
Add –I to Cat. # for Ivory, -W for White, -A for Light Almond, -G for Grey, -B for Black; Single-gang cover plate
ASP-211 included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang cover plate with switch
option, specify color. *Models for 220-240 VAC (WS-230) and 347 VAC (WS-347) are available.

7 800.879.8585 • www.wattstopper.com
WA Automatic Wall Switches

SmartSet™ automatically selects optimal Terminal style wiring simplifies installation


settings for each space
Two relays and dual switch buttons control two
Choice of Auto-ON or Manual-ON operation separate lighting loads or circuits (WA-300)

Built-in light level sensor Audible and/or visual alerts of impending


shut-off
Selectable walk-through mode for
increased savings Vandal resistant hard lens

Specifications Applications
• Universal 100-300 VAC; 50/60 Hz • Built-in light level sensor 8 to 180 • Public area offices
operation fc (86 to 1,937 lux) • Small offices
• 1.0mm hard poly IR2 lens • No minimum load requirement • Small conference rooms
• SmartSet (automatic) time delay or • Compatible with all electronic • Storage closets
fixed (5-30 minute) ballasts and PL lamp ballasts
• SmartSet (automatic) or reduced • 2.6” x 1.7” x 1.9” (66.0mm x
sensitivity 43.2mm x 48.3mm)
• Zero Crossing Circuitry • UL and CUL listed, 5 year warranty

WA-200 Wiring WA-300 Wiring Coverage Pattern

Neutral Neutral White

Coverage shown is for half-


Red Hot BLK step, walking motion,
Load Line Black Red Primary
Load 25'
maximum of 300 ft2. Typical
(7.6m) coverage at the desktop
Ground Blue Brown Secondary
Load level when mounted at 4 ft
GRN Ground is 150 ft2.

10'
The WA-200 can be wired for The WA-300 can be wired for (3.1m)

single-level lighting (shown), or for bi-level (shown) or dual circuit


manual bi-level control. control.

Order Information
CATALOG # DESCRIPTION VOLTAGE LOAD REQUIREMENTS COVERAGE
WA-200 Automatic wall switch 100/120 VAC; 50/60 Hz or 0-800 Watt Ballast or up to 300 ft2
230/277 VAC; 50/60 Hz 0-1200 Watt Ballast (28 m2)
WA-300 Automatic wall switch, 100/120 VAC; 50/60 Hz or 0-800 Watt Ballast or up to 300 ft2
dual relays 230/277 VAC; 50/60 Hz 0-1200 Watt Ballast (28 m2

Add –I to Cat. # for Ivory, -W for White, -A for Light Almond, -G for Grey, -B for Black; Single-gang
cover plate ASP-211 included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang
cover plate with switch option, specify color.

800.879.8585 • www.wattstopper.com 8
WI Automatic Wall Switches

Choice of auto-ON or manual-ON operation Two relays for control of two separate lighting
loads or circuits (WI-300)
4 level lens for superior desktop detection
DIP switch adjustable sensitivity and time delay
Built-in light level sensor

Specifications Applications
• Dual 120/277 VAC • No minimum load requirement • Offices
• Time delay of 15 sec to 30 min (WI- • Compatible with all electronic • Conference rooms
200); 30 sec to 30 min (WI-300) ballasts and PL lamp ballasts
• Built-in light level sensor 10 to 150 • 2.8” x 4.8” x 1.5” (72.1mm x
fc (107 - 1,614 lux) (on secondary 121.9mm x 38.1mm)
relay of WI-300) • UL and CUL listed, 5 year warranty
• LED indicator

WI-200 Wiring WI-300 Wiring Coverage Pattern

Neutral Neutral
277V Ground (GRN/YEL) 0°
120V Ground (GRN) Load
Hot Black
Hot (BLK) Load (RED)
5° 4-level Fresnel lens
Blue Primary detects horizontal and
Load
12° vertical motion.
Secondary
Maximum coverage
Red Red
Load

40'
30° under ideal conditions
Ground (GRN) (12.2m) and for half-step walking
motion is 1000 ft2.

The WI-200 can be wired for The WI-300 can be wired for 15'
single-level lighting (shown), or bi-level (shown) or dual circuit (4.6m)

for manual bi-level control. control.

Order Information
CATALOG # DESCRIPTION VOLTAGE LOAD REQUIREMENTS COVERAGE

WI-200 Automatic wall switch 120 VAC; 60 Hz or 0-800 Watt Ballast or up to 1000 ft2 (92.9m2) 180°
277 VAC; 60 Hz 0-1200 Watt Ballast
WI-300 Automatic wall switch, 120 VAC; 60 Hz or 0-800 Watt Ballast or up to 1000 ft2 (92.9m2) 180°
dual relays 277 VAC; 60 HZ 0-1200 Watt Ballast

Add -W to cat # for White, -A for Light Almond; Order ASP-121 for blank switch 2-gang box
plate; Order ASP-122 for 2-gang box plate with switch option (WI-200 only)

9 800.879.8585 • www.wattstopper.com
WN Motion Sensor Nightlight Switch

Manual-on or automatic-on operation Adjustable time delay from 15 minutes to 2 hours

Energy efficient, super bright LED Impact resistant hard lens

Built in nightlight illuminates whenever Terminal wiring for quick and easy installation
overhead lights are off
Zero Crossing Circuitry increases product
longevity

Specifications Applications
• 120 or 277 VAC, 60 Hz • 2.63” x 1.69” x 1.88” (66.8mm x • Hotel guest bathrooms
• Time delay of 15 min, 30 min, 1 42.9mm x 47.8mm) • Military housing
hour or 2 hours • UL and CUL listed, 5 year warranty • Healthcare facilities
• 1.0mm hard poly IR2 lens

Wiring Diagram Coverage Pattern

The WN-100 can be The WN-100 has a


Neutral
Load wired for single- coverage range of 180°
White
level lighting and a maximum
TOP (shown), or for coverage area of 300
Load Hot
manual bi-level 25'
ft2. To maintain its
Red ON

Black control. coverage capacity and


1 (7.6m)
optimally detect
motion, the WN-100
Ground Neutral must have a clear and
Green INDOOR USE ONLY
White unobstructed view of
10' occupants.
(3.1m)

Order Information
CATALOG # VOLTAGE LOAD REQUIREMENTS COVERAGE
WN-100-120 120 VAC; 60 Hz 0-500W incandescent, fluorescent up to 300 ft2 (28 m2), 180°
and compact fluorescent
WN-100-277 277 VAC; 60 Hz 0-1200W incandescent, fluorescent up to 300 ft2 (28 m2), 180°
and compact fluorescent

Add –I to Cat. # for Ivory, -W for White, -A for Light Almond; Single-gang cover plate ASP-211
included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang cover plate with switch
option, specify color.

800.879.8585 • www.wattstopper.com 10
WD Dimmable Automatic Switch

Occupancy sensing dimmable wall switch Works with dimming ballasts

Slide dimmer adjusts light level Vandal resistant, hard lens

Low profile, flat decorator design ASIC enhances reliability and helps to
eliminate false triggers
Zero voltage turn on/off increases life
of sensor

Specifications Applications
• WD-170, WD-270 operate at 120 • 1.0 mm hard poly IR 2 lens • Small offices
VAC; WD-180, WD-280 operate at • LED indicator • Public area offices
277 VAC • Adjustable sensitivity • Small conference rooms
• WD-170/180 time delay of 30 sec to • 2.7”x1.8”x2.2” (68.9mm x 45.7mm x
30 min 55.9mm)
• WD-270/280 fixed initial 15 min • UL and CUL listed, 5 year warranty
delay for dim; secondary adjustable
delay (5 min to 30 min) for off

Wiring Diagram Coverage Pattern

Neutral
Load

Ground GRN
Hot BLK
Coverage shown is for half-
Load RED

step, walking motion,


maximum of 300 ft2. Typical
25'
(7.6m)
coverage at the desktop
The WD can be wired for level when mounted at 4 ft
single-level lighting is 150 ft2.
(shown) or for manual
bi-level control.
10'
(3.1m)

Order Information
CATALOG # VOLTAGE LOAD REQUIREMENTS COVERAGE OFF MODE
WD-170 120 VAC; 60 Hz 10-500 W Ballast up to 300 ft2 (28 m2) Automatic-OFF
WD-180 277 VAC; 60 Hz 10-500 W Ballast up to 300 ft2 (28 m2) Automatic-OFF
WD-270 120 VAC; 60 Hz 10-500 W Ballast up to 300 ft2 (28 m2) Dim-bef-disconnect

WD-280 277 VAC; 60 Hz 10-500 W Ballast up to 300 ft2 (28 m2) Dim-bef-disconnect

Add –I to Cat. # for Ivory, -W for White, -A for Light Almond; Single-gang cover plate ASP-211
included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang plate with switch option,
specify color. WD-170/180.wiring.single level

11 800.879.8585 • www.wattstopper.com
CN, CW Vacancy Sensors for
Residential Use
Manual-on/automatic-off operation; lights Adjustable time delay from 1 to 30 minutes
cannot be overriden ON
Impact resistant hard lens
CN contains energy efficient nightlight
that illuminates whenever overhead CEC 2005 Title 24 compliant
lights are off

Simple pushbutton programming

Specifications Applications
• 120 VAC, 60 Hz • No minimum load requirement CW CN
• Time delay of 1 min to 30 min • 2.63” x 1.69” x 1.88” (66.8mm x • Hallways • Bathroom
• 1.0mm hard poly IR2 lens 42.9mm x 47.8mm) • Laundry rooms • Bedrooms
• Compatible with 0-500W • UL and CUL listed, 5 year warranty • Garages
incandescent, fluorescent, compact
fluorescent, MLV, and ELV loads

Wiring Diagram Coverage Pattern

Neutral The sensors have a


Load
White coverage range of 180°
and a maximum
coverage area of 300
TOP
Load Hot
Red ON

Black 25' ft2. To maintain its


(7.6m)
coverage capacity and
1

optimally detect
Ground Neutral motion, the sensor
Green INDOOR USE ONLY
White must have a clear and
unobstructed view of
10'
(3.1m) occupants.

Order Information
CATALOG # DESCRIPTION VOLTAGE LOAD REQUIREMENTS COVERAGE
CN-100 Residential vacancy 120 VAC; 60 Hz 0-500W incandescent, fluorescent up to 300 ft2 (28 m2), 180°
sensor with nightlight and compact fluorescent
CW-100 Residential vacancy 120 VAC; 60 Hz 0-500W incandescent, fluorescent up to 300 ft2 (28 m2), 180°
sensor and compact fluorescent

Add –I to Cat. # for Ivory, -W for White, -A for Light Almond. Single-gang cover plate ASP-211 included. Order ASP-422 for blank
2-gang cover plate, ASP-432 for 2-gang cover plate with switch option, specify color.

800.879.8585 • www.wattstopper.com 12
WPIR Passive Infrared Sensor

PIR occupancy sensor turns lights on and off ASIC technology reduces components and
based on occupancy provides greater reliability

User-adjustable sensitivity LED indicator

User-adjustable time delay of 30 sec to 30 min 30 segment multi-element Fresnel lens

Specifications Applications
• Adjustable time delay of 30 sec to • 2.5” x 2.5” x 1.14” • Small offices • Computer rooms
30 min (63.5mm x 63.5mm x 29.0mm) • Copy rooms • Racquetball courts
• Units per power pack: up to 8 (B); • UL and CUL listed, 5 year warranty • Break rooms • Library book stacks
up to 10 (BZ)

Product Controls Wiring Diagram Coverage Pattern


Sensitivity Neutral
Adjustment Load
Load
LED Indicator Override
White Red
Mounting Power
Holes Hot Black Pack Red
Time Delay
SE

Adjustment
SE N
TI
M

Black
E

Blue
Red

Zone 1
Switch Zone 2
Sensor
Window Horizontal Zone 3

coverage
Zone 4
Zone 5

WPIR Sensor pattern

Vertical coverage pattern

5 4 3 2 1

Order Information
CATALOG # VOLTAGE CURRENT COVERAGE
WPIR 24 VDC 14 mA up to 300 ft2 (28 m2)

All units are white and use Watt Stopper power packs

13 800.879.8585 • www.wattstopper.com
CX Pa s s i ve I n f ra re d S e n s o r

Choice of four coverage patterns Swivel mounting bracket for convenient corner
mounting to wall or ceiling
User-adjustable time delay and sensitivity
Built-in light level sensor (CX-100)
ASIC technology reduces components and
provides greater reliability Isolated relay for use with HVAC or other
control systems (CX-100)

Specifications Applications
• Time delay of 15 sec to 30 min • 3.3” x 3.3” x 2.1” (83.8mm x • Large offices • Open office spaces
• Built-in light level sensor 3 to 200 83.8mm x 53.3mm) • Warehouses • Classrooms
fc (32 - 2,152 lux) (CX-100) • UL and CUL listed, 5 year warranty • Computer rooms • High bays
• Units per power pack: CX-100 up to
6 (B), up to 8 (BZ); CX-105 up to 14
(B), up to 18 (BZ)

Wiring & Controls Coverage Patterns


16ft

8ft
White (Neutral) t.
50f 0

Red (Line) 8ft

16ft
N White Power Pack
Lighting
55ft.
Load 10ft
Hot Black Red (Load) Switch TOP

Standard 0 10 15ft 55ft 85 90ft


Black

CX-100, Long Long


Range Lens: CX-100-1, CX-105-1
Blue

Wires
Red

Isolated Relay Outputs


Range Lens (-1)
Normally Closed Contact BRN
Common RED CX-105
Normally Open Contact ORN 10 ft 3 ft
Auxiliary 0
Pack Control Output 24VDC YEL SIDE
Common GRN 0 7 ft 15 ft 25 ft 55ft 33° using MB-1 with
5ft 30ft maximum rotation
Blue Light Level Output 24VDC BLU
0
+24VDC VIO
Black 15ft
Common GRA
30ft Dense Wide Angle Lens (Standard) 15ft

33.5ft 33.5ft 0
Hot OFF switch Light Light 15ft 0
10 ft 0 10 ft 20 ft 30 ft 40 ft 50 ft
Level on
Level
Red (load) Lighting
Sensitivity
0
67ft 38ft 21ft 10ft 0 10ft 21ft 38ft 67ft One Sided Aisleway:
Load 1 2 3 4 5
N CX-100-4, CX-105-4
Time Delay DIP
Two Sided Aisleway: CX-100-3, CX-105-3 Narrow Aisle Lens (-4)
using MB-1 bracket
with maximum rotation
Coverages shown areLensmaximum.
Aisleway (-3)
pointed straight down
Under ideal conditions, coverage for half-step walking motion
(standard lens) can reach up to 2000 ft2 (185.8 m2), for desktop activity up to 1000 ft2 (92.9 m2).

Order Information
CATALOG # VOLTAGE CURRENT COVERAGE FEATURES
CX-100 24 VDC 19 mA up to 2000 ft2 (185.8 m2) light level, isolated relay
CX-100-1 24 VDC 19 mA up to 90 linear ft (27.4 m) light level, isolated relay
CX-100-3 24 VDC 19 mA up to 120 linear ft (36.6 m) light level, isolated relay
CX-100-4 24 VDC 19 mA up to 50 linear ft (15.2 m) light level, isolated relay
CX-105 24 VDC 8 mA up to 2000 ft2 (185.8 m2)
CX-105-1 24 VDC 8 mA up to 90 linear ft (27.4 m)
CX-105-3 24 VDC 8 mA up to 120 linear ft (36.6 m)
CX-105-4 24 VDC 8 mA up to 50 linear ft (15.2 m)

All units are white and use Watt Stopper power packs. Order the MB-1 Industrial Mounting Bracket
for installing the CX in industrial settings such as warehouses.

800.879.8585 • www.wattstopper.com 14
CI-200 Passive Infrared Sensor

360° coverage Isolated relay for use with HVAC or other


control systems (CI-200)
User adjustable time delay and sensitivity
Built-in light level sensor (CI-200)
ASIC enhances reliability and helps
eliminate false triggers

Specifications Applications
• Time delay 15 sec to 30 min • 3.3” diameter x 2.2” total depth • Open or partitioned
• Built-in light level sensor 4 to 190 (83.8mm x 55.9mm) Extends office spaces
fc (43 to 2,045 lux) (CI-200) approx .36” from ceiling • Conference rooms
• SPDT isolated relay (CI-200) • UL and CUL listed, 5 year warranty • Computer rooms
• Units per power pack: CI-200 up to • Classrooms
5 (B), up to 7 (BZ); CI-205 up to 10
(B), up to 13 (BZ)

Wiring & Controls Coverage Patterns


Extended Range Lens : CI-200, CI-205
White / Neutral

Red (Line)
N White Power Pack Lighting DIP Switch 8 ft
Load for Time Delay
Switch and Sensitivity Typical
Hot Black Red (Load) desk-top
level
44 ft
Isolated Relay Outputs Cable
Black

Blue
Red

Closure upon Occupancy Wires


Normally Closed Contact 1-Brn
22 ft 13 ft 7 ft 3 ft 0 3 ft 7 ft 13 ft 22 ft
Common 2-Red
Auxiliary Normally Open Contact 3-Orn
Pack MAX
Control Output 24VDC 4-Yel
Control Return 5-Grn MIN
Blue Light Level Output 24VDC 6-Blu

High Density Lens: CI-200-1, CI-205-1


+24VDC 7-Vio
Black Common 8-Gra

Hot OFF switch Light 8 ft


Level LED
Lighting Light Level
Red (load) Typical
Load Adjustment
desk-top
N level
24 ft
12 ft 9 ft 7 ft 5 ft 3 ft 0 3 ft 5 ft 7 ft 9 ft 12 ft

Coverage shown represents half-step, walking motion.


Typical coverage at the desktop is 500 ft2 (46.5 m2) with
the Extended Range lens and 300 ft2 (111.5 m2) with the
High Density lens.

Order Information
CATALOG # VOLTAGE CURRENT COVERAGE
CI-200 24 VDC 20 mA up to 1200 ft2 (111.5 m2)
CI-200-1 24 VDC 20 mA up to 500 ft2 (46.5 m2)
CI-205 24 VDC 11 mA up to 1200 ft2 (111.5 m2)
CI-205-1 24 VDC 11 mA up to 500 ft2 (46.5 m2)

All units are white and use Watt Stopper power packs.

15 800.879.8585 • www.wattstopper.com
CI-300, CI-355 360° PIR Sensor

Architecturally appealing low profile Accepts low voltage switch input for manual-on
appearance operation (CI-300, CI-305)

SmartSet automatically selects optimal Line and low voltage models available
time delay and sensitivity
Walk-through mode increases
Depluggable terminal wiring for quick and savings potential
easy installation

Specifications Applications
• CI-300, CI-305: 24 VDC/VAC • Isolated relay with N/O and N/C • Units per power pack: CI-300 up • Open offices
• CI-355: 120/230/277/347 VAC, outputs rated for 1 Amp at 30 to 5 (B), up to 7 (BZ); CI-305 up to • Conference rooms
50/60 Hz VDC/VAC (CI-300) 12 (B), up to 16 (BZ) • Classrooms
• Time delays: SmartSet (automatic), • Mounting options: ceiling tile; 4 • 4.5” diameter x 1.02” (144.3mm x • Offices
fixed (5, 10, 15, 20, or 30 minutes), square junction box with double 25.9mm); (83.8mm x 55.9mm)
• Storage rooms
walk-through, test-mode gang mudring (CI-300, CI-305) extends approx .36” from ceiling
• Computer rooms
• Sensitivity adjustment: SmartSet • Mounting options: 4 square • UL and CUL listed, 5 year
(automatic) or reduced sensitivity junction box with double gang warranty
• Built-in light level sensor; 10 to mudring; 4 inch octagonal
300 fc (107 to 3,229 lux) (CI-300, junction box (CI-355)
CI-355)

Wiring Diagrams Coverage Patterns


White (Neutral)

Red (Line)
N White Power Pack
Lighting Extended Range Lens (Standard)
Hot Black Red (Load) Switch
load
CI-300, CI-305, CI-355
Black

Blue

Isolated Relay Outputs 44 ft


Red

Common Relay Common 13.4m 8 ft


Normally Open Contact N.O.
Normally Closed Contact N.C.
Auxiliary Typical
Blue desk-top
Relay Light Level (24VDC Out) level
Pack Control (24VDC) Out
Optional Momentary Switch * Man. Switch
22 ft 13 ft 7 ft 3 ft 0 3 ft 7 ft 13 ft 22 ft
+24V (In)
Black Common
CI-300 Terminals
Hot OFF switch
Light
level
* Connect wire only when Neutral
Red (load) lighting Load
High Density/Reduced Range Lens
N
load momentary switch is installed

CI-300-1, CI-305-1, CI-355-1


CI-300 Wiring Load Hot
24 ft
7.3m 8 ft
Ground Neutral Typical
desk-top
(Optional) level

12 ft 9 ft 7 ft 5 ft 3 ft 0 3 ft 5 ft 7 ft 9 ft 12 ft
CI-355 Wiring

Order Information
CATALOG # VOLTAGE CURRENT/LOAD REQ COVERAGE
CI-300 24 VDC 20 mA up to 1200 ft2 (111.5 m2)
CI-300-1 24 VDC 20 mA up to 500 ft2 (46.5 m2)
CI-305 24 VDC 9 mA up to 1200 ft2 (111.5 m2)
CI-305-1 24 VDC 9 mA up to 500 ft2 (46.5 m2)
CI-355 120 VAC, 50/60 Hz 0-800 W Ballast/Tungsten up to 1200 ft2 (111.5 m2)
230/277 VAC, 50/60 Hz 0-1200 W Ballast
347 VAC, 50/60 Hz 0-1500 W Ballast
CI-355-1 120 VAC, 50/60 Hz 0-800 W Ballast/Tungsten up to 500 ft2 (46.5 m2)
230/277 VAC, 50/60 Hz 0-1200 W Ballast
347 VAC, 50/60 Hz 0-1500 W Ballast

All units are white and low voltage models use Watt Stopper power packs.
For line voltage installations requiring an adapter plate, order cat # CA-1.
800.879.8585 • www.wattstopper.com 16
CI-12,CI-24 Sensor for HVAC, BAS

Ceiling mount 360° sensor Four-level Fresnel lens offers superior desktop
detection
Interfaces directly with EMS or HVAC system
through internal isolated relay Advanced PIR technology

User adjustable time delay and sensitivity via ASIC technology reduces components and
DIP switch enhances reliability

Specifications Applications
• Time delay 30 seconds to 30 • 3.3” diam x 2.2” depth (83.8mm x • Open or partitioned • Computer rooms
minutes 55.9mm) extends approx .36” from office spaces • Classrooms
• Isolated relay rated for 1 Amp at 24 ceiling • Conference rooms
VAC/VDC • UL and CUL listed, 5 year warranty

CB Low Temp Sensor

PIR occupancy sensor for areas of extreme Choice of three coverage patterns
low temperature
Convenient DIP switch adjustments for time
Watertight enclosure prevents moisture and delay and sensitivity
dust from affecting detection
Isolated relay contact for use with HVAC or
other control systems

Specifications Applications
• Time delay 15 sec to 10 min • 3.94”x3.74”x2.36” (100.1mm x • Cold storage and • Unconditioned
• Temperature range -40°F to +95°F 95.0mm x 60.0mm) freezers spaces
• Units per power pack: up to 5 (B); • UL and CUL listed, 5 year warranty
up to 7 (BZ) Wiring Diagram
White / Neutral

Red (Line) Lighting


N White Power Pack Load

Hot Black Red (Load) Switch

CI-12/CI-24 Order Information


Black

Blue
Red

Isolated Relay Outputs Cable


Closure upon Occupancy Wires
Normally Closed Contact 1-Brn
Common 2-Red
Normally Open Contact 3-Orn

CATALOG # VOLTAGE LOAD REQUIREMENTS COVERAGE Control Output 24VDC 4-Yel


5-n/a

12 VDC 28 mA See coverage


LED
CI-12
6-n/a
+24VDC 7-Vio
Control Return 8-Gra
on
DIP
CI-24 24 VAC, VDC 37 mA patterns CI-200
off

Switch

Units are white; Extended Range lens is standard; Add -1 to


Cat# for High Density/Reduced coverage lens.
CB-100 Order Information
CATALOG # VOLTAGE CURRENT COVERAGE
CB-100 24 VDC 20 mA See coverage patterns CX-100

Units are beige; Dense Wide Angle lens is standard; Add-1 to Cat# for Long
Range, -3 for Two Sided Aisle way

17 800.879.8585 • www.wattstopper.com
W Ultrasonic Occupancy Sensor

Advanced, omni-directional, Ideal for open office areas, conference rooms


Doppler technology and restrooms

Adjustable time delay from 15 seconds Advanced Signal Processing Circuitry


to 15 minutes automatically adjusts detection threshold
500, 1000, 2000 sq ft, and hallway
coverages available

Specifications Applications
• Ultrasonic technology with 25KHz • Adjustable sensitivity • Open and partitioned • Storage areas
frequency • Units per power pack: up to 7 (B); spaces • Conference rooms
• Temperature and humidity resistant up to 9 (BZ) • Restrooms • Hallways
receivers • 4.5” x 4.5” x 1.25” (114.3mm x
• Logic key/ON bypass 114.3mm x 31.8mm)
• LED indicator • UL and CUL listed, 5 year warranty

Wiring Diagram Coverage Patterns

Neutral Load W-2000A


Load 20'
W-1000A
29'
White Red 12'
W-500A
Power 24' **W-2000H
10'
Hot Black Pack Red
5'
Coverage shown
represents half-step,
45' 25' 20' 5' 5' 15' 20' 25' 45'
walking motion.
Black
Blue

**W-2000H coverage is
Red

10'

Switch
12' not drawn to scale
20'
sensor
Occupancy Sensor

Order Information
CATALOG # VOLTAGE CURRENT COVERAGE
W-500A 24 VDC 16 mA 360°, 500 ft2 (46.5 m2)
W-1000A 24 VDC 16 mA 360°, 1000 ft2 (92.9 m2)
W-2000A 24 VDC 16 mA 360°, 2000 ft2 (185.8 m2)
W-2000H 24 VDC 16 mA 360°, 90 linear ft (27.4 m)
All units are white and use Watt Stopper power packs.

800.879.8585 • www.wattstopper.com 18
WT Ultrasonic Occupancy Sensor

Ultrasonic technology with 32 KHz frequency User-adjustable DIP switch time delay and
sensitivity settings
Utilizes advanced, omni-directional,
Doppler technology 600, 1100, 2200 sq ft and hallway
coverages available
Advanced Signal Processing automatically
Isolated relay allows sensor to interface with
adjusts detection threshold
building control systems

Specifications Applications
• Ultrasonic technology with 32 KHz • Units per power pack: • Open and partitioned spaces
frequency WT-605 up to 4 (B), 5 (BZ); WT-600 • Restrooms
• Time delay 15 sec to 30 min up to 3 (B), 4 (BZ); WT-1105, WT- • Storage areas
• Isolated relay with N/O and N/C 2205, WT-2255 up to 3 (B), 5 (BZ);
• Conference rooms
outputs; rated for 1 amp @ 30 WT-1100, WT-2200, WT-2250 up to
VDC/VAC 2 (B), 3 (BZ) • Hallways
• 4.8” diam x 1.5” depth (121.9mm x • UL and CUL listed, 5 year warranty
38.1mm)

Wiring & Controls Coverage Patterns

White (Neutral)
45' 26' 22' 0' 22' 26' 45'
Red (Line)

White
21'
N Lighting Transducers WT-2200/2205
Power Pack Load
Black Red (Load) Switch
Hot 14'
WT-1100/1105 WT-600/605
Isolated Relay Outputs Cable
DIP switch
Black

Blue
Red

Closure upon Occupancy Wires


5'
Normally Closed Contact 1 Brn
Common 2 Red LED WT-2250/2255
Normally Open Contact 3 Orn ON 0'
1 2 3 4 5 6

Control Output 24VDC 4 Yel 5'


Control Return 5 Grn
No Connection 6 Blu Sensitivity
+24VDC 7 Vio S

14'
Common 8 Gra
Coverage shown
21' represents half-step,
walking motion

Order Information
CATALOG # VOLTAGE CURRENT COVERAGE FEATURE
WT-605 24 VDC 27 mA 360° one-sided, 600 ft2 (55.7 m2)
WT-600 24 VDC 37 mA 360° one-sided, 600 ft2 (55.7 m2) isolated relay
WT-1105 24 VDC 30 mA 360° two-sided, 1100 ft2 (102.2 m2)
WT-1100 24 VDC 40 mA 360° two-sided, 1100 ft2 (102.2 m2) isolated relay
WT-2205 24 VDC 30 mA 360° two-sided, 2200 ft2 (204.4 m2)
WT-2200 24 VDC 40 mA 360° two-sided, 2200 ft2 (204.4 m2) isolated relay
WT-2255 24 VDC 30 mA 360° two-sided, 90 linear ft (27.4 m)
WT-2250 24 VDC 40 mA 360° two-sided, 90 linear ft (27.7 m) isolated relay

All units are white and use Watt Stopper power packs.

19 800.879.8585 • www.wattstopper.com
UT-300, UT-355 360° Ultrasonic Sensor

Architecturally appealing low Accepts low voltage switch input for manual-on
profile appearance operation (UT-300, UT-305)

SmartSet automatically selects optimal time Ultrasonic diffusers give more


delay and sensitivity comprehensive coverage

Depluggable terminal wiring for quick and Walk-through mode increases


easy installation savings potential

Specifications Applications
• UT-300, UT-305: 24 VDC/VAC • Isolated relay with N/O and N/C mudring; 4 inch octagonal • Restrooms
• UT-355: 120/230/277/347 VAC, outputs rated for 1 Amp at 30 junction box (UT-355) • Large Offices
50/60 Hz VDC/VAC (UT-300) • Units per power pack: UT-300 • Open Offices
• Time delays: SmartSet • Built-in light level sensor; 10 to up to 2 (B), up to 3 (BZ); UT-305
(automatic), fixed (5, 10, 15, 20, 300 fc (107 to 3,229 lux) (UT- up to 3 (B), up to 4 (BZ)
or 30 minutes), walk-through, 300, UT-355) • 4.5” diameter x 1.02” (144.3mm
test-mode • Mounting options: ceiling tile; 4 x 25.9mm) (83.8mm x 55.9mm)
• Sensitivity adjustment: square junction box with double Extends approx .36” from ceiling
SmartSet (automatic) or gang mudring (UT-300, UT-305) • UL and CUL listed, 5 year
reduced sensitivity • Mounting options: 4 square warranty
• Ultrasonic frequency of 40 kHz junction box with double gang

UT-300 Wiring UT-355 Wiring Coverage Patterns


White (Neutral) Neutral 25' 20' 15' 10' 5' 0' 5' 10' 15' 20' 25'
Load
Red (Line)
N White Power Pack 20' UT-300-3
Lighting

Hot Black Red (Load) Switch


load Load Hot 15'
UT-300-2
Black

10' UT-300-1
Blue
Red

Isolated Relay Outputs


Common Relay Common Ground Neutral
Normally Open Contact N.O. 5'
Normally Closed Contact N.C. (Optional)
0'
Control (24VDC) Out
OPTIONAL Momentary Switch* Man. Switch 5'
+24V (In)
Common 10'
UT-300 Terminals
* Connect wire only when 15'
momentary switch is installed

20'

25'

UT-300-1 up to 500 sq ft for walking motion (22.3' x 22.3')


Coverages represent half-step walking
UT-300-2 up to 1000 sq ft for walking motion (31.6' x 31.6')
motion.
UT-300-3Actual coverages
up to 2000 sq ft for walkingcan
motionvary
(44.7' xfor each
44.7')
application based
(walking motion coverageon room shape, use and
shown)

obstacles.

Order Information
CATALOG # VOLTAGE CURRENT/LOAD REQ COVERAGE
UT-300-X 24 VDC 43 mA see diagram
UT-305-X 24 VDC 37 mA
UT-355-X 120 VAC, 50/60 Hz 0-800 W
230/277 VAC, 50/60 Hz Ballast/Tungsten
347 VAC, 50/60 Hz 0-1200 W Ballast
0-1500 W Ballast

X = 1 for 500 ft2 of coverage; -2 for 1000 ft2; -3 for 2000 ft2.
All units are white and low voltage models use Watt Stopper power packs.
For line voltage installations requiring an adapter plate, order cat # CA-1.

800.879.8585 • www.wattstopper.com 20
DT-200 Dual Technology Sensor

Combines passive infrared and SmartSet automatically selects optimal settings


ultrasonic technologies for each space

Trouble-free lighting control in applications Accepts low voltage switch input for
difficult for single technology sensors manual-on operation

Built-in light level sensor Walk-through mode increases savings


potential

Specifications Applications
• 24 VDC/VAC • SPDT isolated relay (DT-200) • 4.4" x 3.4" x 2" (111.8mm x • Classrooms
• Ultrasonic frequency of 40 kHz • Isolated relay with N/O and N/C 86.4mm x 50.8mm) • Conference and training
• Time delays: SmartSet outputs rated for 1 Amp at 24 • UL and CUL listed, 5 year rooms
(automatic), fixed (5, 10, 15, 20, VDC/VAC (DT-200) warranty • Large offices
or 30 minutes), walk-through, • Built-in light level sensor; 2 to
test-mode 200 fc (21 to 2,152) lux) (DT-200)
• Sensitivity adjustment: • Units per power pack: DT-200
SmartSet (automatic) or up to 3 (B), up to 4 (BZ); DT-205
reduced sensitivity up to 4 (B), up to 5 (BZ)

Wiring Diagram Coverage Pattern


White (Neutral)

Red (Line)
N White Power Pack
Lighting
load
Hot Black Red (Load) Switch

Coverages shown are


Black

PIR
Blue
Red

Isolated Relay Outputs


Common RED
coverage maximum. Under ideal
Normally Open Contact ORG 55ft. conditions, coverage for
Normally Closed Contact BRN
Auxiliary Ultrasonic half-step walking
Relay Blue Light Level (24VDC Out) BLU
Pack Control (24VDC) Out YEL
coverage motion (standard lens)
38ft.
Momentary Switch GRN can reach up to 2000 ft2,
+24V (In) VIO
Black Common GRA
for desktop activity up
DT-200 to 1000 ft2.
wires
Hot OFF switch
Light 10 ft
level
Red (load) lighting
N
load

0 7 ft 15 ft 25 ft 55ft

Dense Wide Angle Lens (Standard)


Order Information
CATALOG # VOLTAGE CURRENT COVERAGE FEATURES
DT-200 24 VDC 43 mA 2000 ft2 (185.8 m2) light level, isolated relay
DT-205 24 VDC 35 mA 2000 ft2 (185.8 m2)

All units are white and use Watt Stopper power packs.

21 800.879.8585 • www.wattstopper.com
DT-300 360° Dual Technology Sensors

Architecturally appealing low profile Accepts low voltage switch input for manual-on
appearance operation (DT-300, DT-305)

SmartSet™ automatically selects optimal Depluggable terminal wiring for quick and easy
settings for each space installation

Walk-through mode increases savings potential


Ultrasonic diffusers give more
comprehensive coverage
line and low voltage models available

Specifications Applications
• DT-300, DT-305: 24 VDC/VAC • Isolated relay with N/O and N/C mudring; 4 inch octagonal • Classrooms
• DT-355: 120/230/277/347 VAC, outputs rated for 1 Amp at 30 junction box (DT-355) • Open office spaces
50/60 Hz VDC/VAC (DT-300) • Units per power pack: DT-300 • Computer rooms
• Time delays: SmartSet • Built-in light level sensor; 10 to up to 2 (B), up to 3 (BZ); DT-305
(automatic), fixed (5, 10, 15, 20, 300 fc (107 to 3,229 lux) (DT-300, up to 3 (B), up to 4 (BZ)
or 30 minutes), walk-through, DT-355) • 4.5” diameter x 1.02” (144.3mm
test-mode • Mounting options: ceiling tile; 4 x 25.9mm) Extends approx .36”
• Sensitivity adjustment: SmartSet square junction box with double from ceiling
(automatic) or reduced gang mudring (DT-300, DT-305) • UL and CUL listed, 5 year
sensitivity • Mounting options: 4 square warranty
• Ultrasonic frequency of 40 kHz junction box with double gang

Wiring Diagrams Coverage Pattern


White (Neutral)

Red (Line)
N White Power Pack
Lighting
load
Hot Black Red (Load) Switch
Black

Blue
Red

Isolated Relay Outputs


Common Relay Common Neutral
Normally Open Contact N.O. Load
Auxiliary
Normally Closed Contact N.C.
44 ft
Relay Blue Light Level (24VDC Out) (13.4m)
Pack Control (24VDC) Out
Momentary Switch Man. Switch
Load Hot
+24V (In)
Black Common
DT-300 Terminals
Hot OFF switch
Ground Neutral
Light
level (Optional)
Red (load) lighting
N
load 40 ft x 40 ft
(12.2m x 12.2m)
DT-300 Wiring DT-355 Wiring
Coverage shown is maximum and represents
Wiring diagram includes bi-level control and half-step walking motion. Under ideal conditions,
manual-on option with momentary switch. coverage for half-step walking motion can reach
up to 1000 ft2 (92.9 m2).

Order Information
CATALOG # VOLTAGE CURRENT/LOAD REQ COVERAGE
DT-300 24 VDC 43 mA up to 1000 ft2 (92.9 m2)
DT-305 24 VDC 35 mA up to 1000 ft2 (92.9 m2)
DT-355 120 VAC, 50/60 Hz 0-800 W Ballast/Tungsten up to 1000 ft2 (92.9 m2)
230/277 VAC, 50/60 Hz 0-1200 W Ballast up to 1000 ft2 (92.9 m2)
347 VAC, 50/60 Hz 0-1500 W Ballast up to 1000 ft2 (92.9 m2)

All units are white and low voltage models use Watt Stopper power packs.
For line voltage installations requiring an adapter plate, order cat # CA-1.

800.879.8585 • www.wattstopper.com 22
Power Packs

Fully self-continued transformer and relay Two-relay output power pack that accepts signals
from multiple control devices (LC-100)
Many models of power pack products for
wide range of applications Daylighting control with photosensor (LC-100)

Plenum rated 2 channel dimming with 0-10V ballasts (LC-100)

Load shed dimming or ON/OFF switching


capability (LC-100)

B Power Pack Specifications BZ Specifications LC-100 Specifications


• Secondary voltage of 24VDC • 120/277 VAC voltage input, 60 Hz • 120/277 VAC voltage input, 50/60 Hz
• Secondary output of 150 mA, 114 mA with • Secondary voltage of 24VDC • 2 relay outputs rated 20 Amp 120V
relay connected • Secondary output of 150 mA, 150 mA with tungsten and ballast, 20 Amp 277V ballast
• Low voltage leads rated for 300 volts relay connected • Secondary output of 150 mA, 150 mA with
• UL rated 94V-0 plastic enclosure, units • Low voltage leads rated for 300 volts relay connected
are white • UL rated 94V-0 plastic enclosure, units • Dual switch inputs for on/off or dimming
• ABS UL 2043 plenum rated plastic and are grey • 2 isolated NO/NC relays rated 1 Amp @ 24
wiring • ABS UL 2043 plenum rated plastic and VDC
• 1.6" x 2.75" x 1.6" (41mm x 70mm x wiring • NEMA 1 enclosure, acceptable for use in
41mm) with a 1/2’ snap-in nipple • Relay is Zero Crossing plenum spaces
• UL and CUL listed, 5 year warranty • Hold-ON/hold-OFF inputs • Output power 150mA @ 24 VDC with
• LED status and overcurrent indicator automatic overload protection
• 1.6" x 2.75" x 1.6" (41mm x 70mm x • Dual voltage input 120 or 277 VAC @ 14
41mm) with a 1/2’ snap-in nipple watts maximum
• UL and CUL listed, 5 year warranty • Switch wiring distances up to 1000 feet
with 18 gauge wire
• 6.6" x 6.1" x 2.1" (168mm x 156mm x
54mm) with a 1/2’ nipple
• UL and CUL listed, 5 year warranty
Order Information
LOAD RATINGS
CATALOG # INPUT VOLTAGE BALLAST(A) INCAN(A) MOTOR(HP) OUTPUT

Power Packs
B120E-P 120VAC, 60Hz 20 13 1 24VDC; 150mA***
B277E-P 277VAC, 60Hz 20 - - 24VDC; 150mA***
B230E-P 220-240VAC, 50/60Hz 20 13 1 24VDC; 150mA***
B347D-P 347VAC, 60Hz 15 - 24VDC; 150mA***
BZ-100 120/277VAC, 60Hz 20 20 1 24VDC; 150mA†
LC-100 120/277 VAC; 50/60 Hz 20 20 1 24VDC; 150mA†
Auxiliary Packs
S120/277/ 120/277/347VAC 20/20/15 13/-/- 1/-/- -
347E-P
Form C Power Packs
A120C-P** 120VAC, 60Hz 8NO/5NC 5NO/3NC 1NO/2.5NC 24VDC; 100mA
A277C-P** 277VAC, 60Hz 6NO/3NC 5NO/2.5NC 2NO/.5NC 24VDC; 100mA
2 Relay Power Packs
C120E-P 120VAC, 60Hz 20* 13* 1* 24VDC; 150mA
C277E-P 277VAC, 60Hz 20* - - 24VDC; 150mA
Power Supplies
AT-120 120VAC, 60Hz - - - 24VDC; 800mA
AT-277 277VAC, 60Hz - - - 24VDC; 800mA

* Ratings per relay. ** Contain an isolated relay with normally open (NO) and normally closed (NC)
contacts. ***Output is 150mA before relay is connected and 114mA after relay is connected.
†Output is 150mA with relay connected.

23 800.879.8585 • www.wattstopper.com
Outdoor Motion Sensors

Optional model with lampholders Line and low voltage models available

Weatherproof and raintight for reliable 90 degree or long-range field of view (EN)
performance
Security override-ON option allows lights to be
Adjustable light level and time delay turned on for length of time delay
settings
Isolated relay enables interface with security
systems or other loads

EW Specifications EN Specifications
• Operating temperature range: - • Zero Crossing Circuitry • Operating temperature range: - • Manual override-ON allows
40°F to +130°F • 1/2’ threaded nipple fits 40°F to +130°F lights to be turned on for 4
• UL 773A rated raintight; UL 1571 standard NEMA weatherproof • UL 773A rated raintight; UL hours
rated for wet locations fixture fitting 1571 rated for wet locations • 3/4’ threaded nipple fits
• Adjustable time delay of 12 sec • Lamp holders us PAR 20 or 38 • Adjustable time delay of 12 sec standard NEMA weatherproof
to 16 min lamps, up to 150W each lamp fixture fitting
to 16 min
• Light level adjustment of .5 to • EW sensor: 6.7” x 3.2” x 2.2”
• Light level adjustment of .4 to • 4.3” x 3.0” x 2.3” (110mm x
200 fc (5 - 2152 lux) (170mm x 80mm x 55mm)
42 fc (4.3 - 452 lux) 77mm x 58mm)
• Isolated relay with NO/NC • UL and CUL listed, 5 year
outputs; rated for 1 Amp @ 30 warranty • SPDT isolated relay • UL and CUL listed, 5 year
VDC/VAC (EW-200) • Zero Crossing Circuitry warranty

Applications Applications
• Walkways and entranceways • Garages and yards • Walkways and entranceways • Doorways
• Dock lighting • Driveways • Dock lighting • Corridors

EW Order Information
CATALOG # VOLTAGE LOAD REQ/CURRENT * COVERAGE FEATURES
EW-200 - 120, - 277 VAC 0-1000 W ballast 270° Isolated relay
EWF-205 - 120 VAC 0-1000 W ballast 270° Lamp holders
EW-205-24 24 VDC 8 mA 270° Controls outdoor HIDs
EW-105-24 24 VDC 8 mA 180° Controls outdoor HIDs

Specify voltage by adding -120 or -277 to Cat. #. Add -W to Cat. # for


Arctic White, -G for Architectural Grey
*For 120 VAC applications, tungsten loads are also acceptable.

EN Order Information
CATALOG # VOLTAGE LOAD REQUIREMENT* COVERAGE FEATURES
EN-100 - 120, - 277 VAC 0-1000 W ballast 90° Isolated relay
EN-200 - 120, - 277 VAC 0-1000 W ballast Long range Isolated relay

Specify voltage by adding -120 or -277 to Cat. #. Add -W to Cat. # for Arctic White, -G for
Architectural Grey
*For 120 VAC applications, tungsten loads are also acceptable.

800.879.8585 • www.wattstopper.com 24
IT-200 InteliTimer Logger

Determines energy savings potential from IT-ProSoft Software provides single-step data
occupancy sensor use retrieval, storage, analysis, printing

Adjustable light pipe observes lighting level Logs when a space is occupied/ vacant and
when lighting is on/off
Logs when a space is occupied/ vacant and
when lighting is on/off Small and lightweight for ease of use
and portability

IT-200 Specifications IT-ProSoft Software Specifications


• PIR technology • Recessed reset switch • List entries include number, date, • Reports show graphs of
• Lithium battery; 10 year average • Stores up to 4096 entries time of entry, and occupancy/lighting, potential
life • Stores site name to identify area lighting/occupancy status dollar savings, statistical
• Test button to activate being monitored • Users set energy cost per kWh, information
occupancy and light level LEDs • Connects to PC for data size of controlled load, and site • Operable in 6 languages
for 90 seconds retrieval name • Windows compatible
• Adjustable sensitivity • HVAC adder calculates savings • Downloadable at
from reduction of cooling www.wattstopper.com

IT-200 Controls Sample Logger Reports


Graphs of Lighting/Occupancy for Office Suite #301

Date of Entries Midnight 06:00 AM Noon 06:00 PM


Occupancy Monday
sensor lens January 8
Ä
Ä
Light pipe
Light level graph indicates Monitored Area Lit Ä
Ägraph indicates Monitored Area Occupied
sensitivity
adjustment Entries: 42 Cost/kWhr: $0.080
From: Sun, Aug 14, 1995 at12:00:00 PM HVAC Adder: 15%
To: Thu, Aug 18, 1995 at 9:32:00 PM Load Size: 180W
LIGHTING/OCCUPANCY SUMMARY
1 Sun, Aug 14, 1995 at12:00:00 PM Lights ON Occupied
2 Sun, Aug 14, 1995 at 2:25:00 PM Lights ON Vacant
ON+Occupied: 59.81 hours 17.8%
Reset button Test button 3
4
Mon, Aug 15, 1995 at 7:50:00 AM Lights ON Occupied
Mon, Aug 15, 1995 at10:15:00 AM Lights ON Vacant
(activates 5 Mon, Aug 15, 1995 at10:50:00 AM Lights ON Occupied
ON+Vacant: 80.64 hours 24.0%

LEDs) 6 Mon, Aug 15, 1995 at12:15:00 PM Lights OFF Vacant OFF+Occupied: 0 hours 0.0%

OFF+Vacant: 195.55 hours 58.2%

Red LED Green LED


(occupancy) (light)
Data connector
port

Order Information
CATALOG # DESCRIPTION
IT-200 Occupancy and light logger, PC connector cable included

All units are white

25 800.879.8585 • www.wattstopper.com
TS Digital Time Switches

Automatically turns lights off after Terminal style wiring for simplified installation
preset time
Digital operation and simple
Bright electroluminescent LCD shows pushbutton set-up
timer’s countdown
Time scroll features allows time to adjust
Optional audible or visual alerts before
up or down
lights turn off

Specifications Applications
• TS-400: 100-300 AC; 50/60 Hz • Optional visual warning: • TS-400-24 contains SPDT • Equipment rooms
• TS-400-24: 24 VAC/VDC/VAC flashes lights at 5 min and 1 isolated relay rated for 1 Amp • Storage areas
half-wave rectified input min prior to time-out @ 30 VDC • Closets
• Time out adjustments range • Optional audible warning: • 2.66” x 1.79” x 1.76” (67.5mm x
from 5 minutes to 12 hours (5 beeps every 5 sec at 1 min 45.5mm x 44.7mm)
minute increments to 1 hour, prior to time-out • UL and CUL listed, 5 year
then 15 minute increments to • Compatible with all electronic warranty
12 hours) ballasts and motor loads

TS-400 Wiring Diagram TS-400-24 Wiring Diagrams


White (Neutral)
Hot
Red (Line) InteliSwitch®
+24V IN (BLU)
Digital Time Switch

Lighting
Neutral TS-400-24 +24V IN
COMM. (WHT)
Load White
Power
Load COMM.

N.C.
Neut RLY
COMM. PULSE OFF (BLK)
Pack ON
N.O.

Black Red 1
PULSE
ON
PULSE PULSE ON (RED)
OFF

Hot (Load)
Local #20/4
Load

OFF Switch
Blue

To Panel
1000' MAX.
Black
Ground

RLY COMM
Red

To circuit
COMM
ON
ON

1
N.O. On Off Comm 24VRect
1

+24V IN
Red Black White Blue
Line

TS-400-24 wiring with power pack TS-400-24 wiring with lighting control panel

Order Information
CATALOG # VOLTAGE LOAD REQ/CURRENT
TS-400 100/120 VAC or 0-800 Watt ballasts or
220/277 VAC; 50/60 Hz 0-1200 Watt ballast
TS-400-24 24 VAC/VDC/VAC rect. Current: 12mA DC/41mA AC

Add –I to Cat. # for Ivory, -W for White, -A for Light Almond; Single-gang cover plate ASP-211
included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang plate with switch option,
specify color.

800.879.8585 • www.wattstopper.com 26
Product Line Summary
WS-200 120/277 VAC; 60 Hz Automatic wall switch Passive infrared

WA-200 120/277 230/277 VAC, 50/60 Hz Automatic wall switch Passive infrared
WA-300 120/277 230/277 VAC, 50/60 Hz -with dual relays Passive infrared

WI-200 120/277 VAC; 60 Hz Automatic wall switch Passive infrared


WI-300 120/277 VAC; 60 Hz -with dual relays Passive infrared

WN-100-120 120 VAC, 60 Hz Motion sensor nightlight switch Passive infrared


WN-100-277 277 VAC, 60 Hz Motion sensor nightlight switch Passive infrared

WD Series 120 or 277 VAC; 60 Hz Dimmable wall switch Passive infrared

CN-100 120 VAC, 60 Hz Residential vacancy sensor Passive infrared


CW-100 120 VAC, 60 Hz Residential vacancy sensor Passive infrared

WPIR 24 VDC Ceiling mount sensor Passive infrared

CX Series 24 VDC Ceiling/wall mount sensor Passive infrared

CI-200 Series 24 VDC Ceiling mount sensor Passive infrared

CI-300 Series 24 VDC Ceiling mount sensor Passive infrared


CI-355 Series 120/230/277/347 VAC; 50/60 Hz Ceiling mount sensor Passive infrared

CI-12/24 12/24 VDC Sensor for HVAC, BAS Passive infrared

CB-100 24 VDC Low temperature sensor Passive infrared

W Series 24 VDC Ceiling mount sensor Ultrasonic

WT Series 24 VDC Ceiling mount sensor Ultrasonic

UT-300 Series 24 VDC Ceiling mount sensor Ultrasonic


UT-355 Series 120/230/277/347 VAC; 50/60 Hz Ceiling mount sensor Ultrasonic

DT-200 Series 24 VDC Ceiling/wall mount sensor Dual technology

DT-300 Series 24 VDC Ceiling mount sensor Dual technology


DT-355 Series 120/230/277/347 VAC; 50/60 Hz Ceiling mount sensor Dual technology

WS-05-20050 800.879.8585 • www.wattstopper.com