Professional Documents
Culture Documents
E203 PDF
E203 PDF
SD/OOB TYPICAL DETAIL OF BRICK OR R.C. PARTITION WALL AND WALL BASE
SD/014 REQUIREMENT OF SPACER BLOCK, 'U' BARS AND STEEL CHAIRS FOR STRUCTURAL ELEMENTS
SD/022 TYPICAL DETAIL OF EXTERNAL DRIVEWAY AND CARPARK GROUND SLAB ON GRADE (1 OF 5)
SD/023 TYPICAL DETAIL OF EXTERNAL DRIVEWAY AND CARPARK GROUND SLAB ON GRADE (2 OF 5)
SD/024 TYPICAL DETAIL OF EXTERNAL DRIVEWAY AND CARPARK GROUND SLAB ON GRADE (3 OF 5)
SD/025 TYPICAL DETAIL OF EXTERNAL DRIVEWAY AND CARPARK GROUND SLAB ON GRADE (4 OF 5)
SD/026 TYPICAL DETAIL OF EXTERNAL DRIVEWAY AND CARPARK GROUND SLAB ON GRADE (5 OF 5)
DRAWING LIST OF
CSE/l C.T. WONG ~AR.'2012 SD/001 B N.T.S.
~
SEB TYPICAL DETAILS approved date STRU. ENGG. BRANCH
AD(SE) W.W. LI MAR., 2012 ARCH. SERVICES DEPT.
GENERAL NOTES:
1. DRAWINGS SD/OOl TO SD/026 (FIG. 1 TO 16 INCLUSIVE) INDICATE THE REQUIREMENT
AND DETAILS GENERALLY ADOPTED IN R.C. WORKS.
IF DIFFERENT DETAILS ARE GIVEN IN R.C. DRAWINGS ISSUED IN THE CONTRACT,
THE DETAILS IN THE LATTER SHALL TAKE PRECEDENCE.
~po::e
~NTfRNAL
...r VI
~
VI
<
'&-1 RAD'US '&~
T T
10 30
12 36
16 48
20 60
25 100
32 128
40 160
-
FIG. 1 CRANKING OF BARS
~
Ig SIZE AND LENGTH ALL IN MILLIMETRES
~
~ ~.
c...
C
c...
c NOTES:
Fe Co Fe Co
N Q Q
g: 1. FOR ANCHORAGE OR LAP BElWEEN BARS OF SAME BAR SIZE, USE I/J = SIZE OF BARS.
§ CD CD
3 -§ -
3
2. FOR ANCHORAGE OR LAP BElWEEN BARS OF DIFFERENT BAR SIZE, USE r/J = SIZE OF SMAlLER BARS.
a.
a
!.
::I
..0
~3a ::I
.
.::t:c: ?
(/)f'TI
(/)
0
~~
P
,
n 0
0
[rim ~ TABLE 2 ANCHORAGE & LAP LENGTH REQUIREMENT FOR
:t o~
N f'TIo HIGH YIELD & PLAIN ROUND (MILD) STEEL REINFORCEMENT
z VJ
0 n
;-. 0
- .~::t:
)( a;-
Yl
N
to
--.J
L
r- r· , J
1It----lI---I---II+- (TYPE A) (TYPE B)
u--___-~ (TYPE B) 111-----11+- (TYPE C)
SPACER BAR -----f*---, (TYPE E)
\'l-1500 c/c
SPACER BARS
E
E
& 0
0"
~ A'
5CD
E
E
o
&"
~ A' 5CD
5CD
¢
I-
::::>
CD
~ A\
5CD
lYPE D
+
u
TYPE F
I 10¢
I BUT ~ 70mm
'if'
E
E I-
::::>
0
CD
&
0 "
~
A'
I-
::::> BEAM STIRRUPS 1YPE M AND TYPE N
CD
-'- SHALL NOT BE USED UNLESS SPECIFIED
ON THE BEAM DETAIL DRAWINGS.
L~ 10¢
BUT ~ 70mm
FIG. 1b
TYPE M TYPE N (r ) REFER TO TABLE 1 ( SO/003 )
ll~• • •
"II re • .".
• •
•
a •
\
• •
•
[] •
•
• [J
• • • 0 • • • • • • • •
FIG. 20 TORSION STIRRUPS
E E
E E
,&0 ,&0
or-- or--
~ A\ ~ A\
I-
::::>
CD
lYPE D lYPE
< 150mm
-j r-
- .. -')
(lYPE c)
1I-----1---f+- (TYPE C) b ...
(lYPE A) OR
~--I-I- (TYPE D) 0R •
(lYPE E)
-,-,
-
FIG. 2b lYPICAl DETAil OF COLUMN BINDERS
FOR COLUMN BINDERS : ( r) REFER TO TABLE 1 ( SD/003 )
1 : 1 SCAlf BAR
I
I A4 210 x
TLL
I· ·1
: } { : : :
11 s
i i s
OR
'I
TLL
I· ·1
If i i s
:
s
: } { : :: : : )1
S = SPACING OF BARS
WAll END
<: n
.. :<
~-
..
0- 0
"., .," 5"'<1 "., ?
OR < , 0
o 0
-.J
-.J
....:
o
1\
0
]
~ e 10 c
o e ~ c
.JV- l..;y.
../'y-
TEE JUNCTION rV'-
o 0 ., 0
-'r-- " e 9 ~
~
.-
8 TWO BARS SHOULD BE PLACED WITHIN LOOP en
-=- Ul
c>
"
~
"-
0
ft ',/
7-
1----' ..-
-
s l
'1
s
'1
l s 1
'1
s 1
'1
T.L.L. TLL
S = SPACING OF BARS
-
0
~
l" JUNCTION
-
FIG. 3 TYPICAL WALL JUNCTION DETAILS (PLAN)
1 1 1 1
NOTES:
1. PARTITION WALLS WITH NOMINAL REINFORCEMENT
ARE NOT CONSIDERED AS LOAOBEARING
STRUCTURAl MEMBERS AND HENCE
REINFORCEMENT WILL NOT BE MEASURED
SEPARATELY, BUT DEEMED INCLUDED IN THE
RATES AS FOR OTHER ARCHITECTURAL
FEATURES.
h h
2. SLAB THICKNESS & REINFORCEMENT APPUCABLE
TO BRICK PARTITION WAlL BASES.
6T10
FIG. 4 1YPICAL DETAIL OF BRICK OR R.C. PARTITION WALL & WALL BASE
drawing title checked date drawing no. scale
TYPICAL DETAIL OF BRICK GSEll CJ. WONG ~ JULY, 2008 SD/008 N.T.S.
~.
-'
-'
I-
FL LEV
-~
? ?
-'
-'
I-
GRD LEV
l
"V'
• l
V~/(', ~ V ~/:"-J
HARDCORE J . V
REFER RELEVANT
.
r-....l~
~
/
STR UCTURAL DRAWINGS
TRIMMING BARS
(TYING WIRE AT ALL INTERSECTIONS)
SEC. A - A
ELEVATION TRIMMING BARS
(TYING WIRE AT ALL INTERSECTIONS)
r- ..-- TRIMMING BARS
(TYING WIRE AT AlL INTERSECTIONS)
I .
~
~ L..------L... WALL REINFORCEMENT
75
- - WALL REINFORCEMENT
2. FOR NON-LOADBEARING WALLS WHERE OPENING WIDTH (L1) > 2m, OR FOR ALL SIZE OF OPENING IN
STRUCTURAL WALLS, THE LOCATION AND SIZE OF THE OPENING SHALL BE APPROVED BY THE PROJECT
STRUCTURAL ENGINEER. DETAILS AND AMOUNT OF TRIMMING BARS SHALL BE SPECIFIED BY THE PROJECT
STRUCTURAL ENGINEER. REFER ALSO TO WALL DETAIL DRAWINGS.
3. UNDER NORMAL SITUATION, IF OPENING WIDTH (L1) < BAR SPACING, NO TRIMMING BAR IS REQUIRED.
50
AO(sE)
0
'1LW. LI
10
rdd20 30 40
JULY. 2008
50 mm
ARCH. SERVICES DEPT.
A4 210 x 297~
11111111111 I I I I
1 : 1 SCAI.£ BAR
-r
2 )( 1T16 T 8£ B
~
/
- ~~ ......
f~"""
IY ~ \.::J
I ill II II
I II '-2 )( 1T16 T 8£ B
AFFECTED BARS
PLAN
300
II
LL AND ~ 2h
U-BARS TO LAP THjE U-BARS TO LAP THE 1 r- Tl0 EXTRA BARS
AFFECTED BARS --:: AFFECTED BARS
~:: :~:::::::;:::::: ~ T
t=;:::::t: -"
B~: ~ -? ..c1
1T16 T 8£ B ~ 1. 1T16 T 8£ • --
NOTES:
1. FIG. 7 IS APPLICABLE FOR OPENINGS THAT :-
o. WITH SLAB THICKNESS ~ 200mm
b. HAVE OPENING SIZE NOT MORE THAN 600mm OR 0.25 x SPAN LENGTH OF SLAB
c. DETAIL NOT APPLICABLE TO OPENINGS IN CANTILEVER SLABS
8
-=. 2. IF SIZE OF OPENING < 200mm, DISPLACE BARS TO SIDES OF OPENING, NO EXTRA TRIMMING BARS
REQUIRED.
-
3. FOR SIZE OF OPENING BETWEEN 200mm & 600mm, ADD TRIMMING BARS AS STATED IN THE FIGURE,
- OR THE AREA OF TRIMMING BAR ON ONE SIDE EQUAL TO HALF THE AREA OF THE AFFECTED BARS IN
THE CORRESPONDING DIRECTION CUT BY THE OPENING, WHICHEVER IS THE GREATER.
- 4. FOR LARGER SIZE OF SLAB OPENING, DETAILS OF STEEL ARRANGEMENT SHALL BE SPECIFIED BY THE
PROJECT STRUCTURAL ENGINEER. REFER ALSO TO SLAB DETAIL DRAWINGS.
-
,,
1----.-,""T,-t--L-- TRIMMING BAR TO BE SPECIFIED BY
THE PROJECT TRUCTURAL ENGINEER
IF NEEDED
SlAB REINFORCEMENT --'----------t-i
I I
SEC. A - A
NOTES:
THE FIGURE IS APPLICABLE TO TEMPORARY SLAB OPENING THE SIZE AND LOCATION OF WHICH
SHALL BE APPROVED BY THE PROJECT STRUCTURAL ENGINEER BEFORE CONSTRUCTION.
r-- . .
SLAB REINF'T.
I
1
I
I 1',,,- <""" //
I
I
I ~
I',
DIA & SPACING SAME AS LAB REINF'T.
//~
I I
I I ', -I
F= /
/
~
'L... t:z
E I . G:i
o
o
E
It: I
I
I ' ',-'\;- //
/ 0:::
Vl~
0:::
Lf)
I~
v 10::: IIt I m~' ' / / I,TlL~
C,!)
:z I~ I I 1 'x/ '1I
C5
0...
I 1 ~ /,
o
lL.
--------~I-+--I~I--~I------- //', ~
o
I I I / / -'", , <0...(3
I I / ,Vl
I II I / / -I 'O'd
,~
-------
F=
I
I I 1// '~
I I-~----- - - - -
I 1//1 "
~----------~
WALL - - t -
CD
:5
en
8
-=-
-
~r=f : .• .•
:z
~
u
~
-
- SEC. A - A
- NOTES:
THE FIGURE IS APPLICABLE TO TEMPORARY SLAB OPENING THE SIZE AND LOCATION OF WHICH
SHALL BE APPROVED BY THE PROJECT STRUCTURAL ENGINEER BEFORE CONSTRUCTION.
-
FIG. 9 1YPICAL DETAIL FOR LARGER TEMPORARY PIPE DUCT OPENINGS
- lYPICAL DETAIL FOR CSE/l C.T. WONG JULY. 2008 SO/013 N.T.S.
~
@600 clc MAX.
SECTION OF SLAB
( :
FORMWORK T12 "u" BAR
COVER SPACERS MAX. SPACING: 1500 c/c B.W.
SPACERS WITH
TIE WIRES
)§§~- FORMWORK
COVER SPACERS
SECTION OF BEAM
NOTES:
THE DIAMETER AND SPACING OF CHAIRS ARE GIVEN AS MINIMUM REQUIREMENT,
THE CONTRACTOR HAS TO PUT IN ADDITIONAL CHAIRS WHERE NECESSARY TO SUPPORT
THE REINFORCEMENT FROM SAGGING OR DISPLACEMENT.
REQUIREMENT OF SPACER
BLOCK, 'u' BARS AND
CSE/l C.T. WONG ~ JULY, 2008 SD/014 N.T.S.
I J
I I
TAL I ~ O.lSl1 ~ O.25L j;J O.25L ~ 0.15L2
AND ~ 45(1\1 AND ~ 45(1\3 AND ~ 45¢3 AND ~ 45¢4
TAL +
~~ LES ER (O.5h 0R 8(4)
r ~ r ~
Q
'" -
~ L BEAM BAR OF DIA, ~1 - L BEAM BAR OF DIA, ~3 BEAM BAR OF DIA, ~4 ~ -
(") 0 -r-- ,-
~ a V1 J
Vi'
,..., CD LANTI-CRACK WEB BARS OF DIA ¢s, FOR BEAM DEPTH> 750 BEAM BAR OF DIA, ~5 --.
........ 0 -'-
0 7':'
""., S
0 CD -'-
("")
<
III
~ CD a. 12(1\s L BEAM BAR OF DIA, ~2 ~ 0.75h
a. ;-t ~ BEAM
~ 12!11~- ~ ~
:::E
DEPTH LAP
0 0 12¢5
:z
G") I- Lf
FLOOR BEAM FLOOR BEAM h
.. N
0
- SPAN L1 SPAN L2
I I I
~ ~
NOTE: L = THE GREATER OF 11 AND L2
~
I t 1
is
<- <-
c: c:
E< a. E< a.
U! a N a
0 ~ CD 800 CD
3 ~ - -
3
c..
a
!.
::l NOTES:
<0
~~ ::l
.:I:c:
. ? 1. FOR ARRANGEMENT OF REINFORCEMENT IN EXTERIOR COLUMN AND BEAM JUNCTION
U)r'Tl AT ROOF LEVEL REFER TO ORG No. 50/018.
r'Tlz U)
~C') a
("')!"> "'-
0
"'m (]'I FIG. 11 CURTAILMENT OF LONGITUDINAL BARS IN BEAM
~ ~~
r'Tl
~ n
z: CIl
0 ~:I: (")
;-t 0
x ~ ii>
N
cD
L
L_r
.h
r
111-_--::£---- .... --j--------...,
J~/ I ;
SEE NOTE 1
I
ANTICRA.CK WEB BAR REQUIRED
.IF BEAM DEPTH > 750mm
1 I ; I
iJ-J------ -J-----------
I_ 1U. .1 ~ ElfAII U.N R8NFORCEMENT
ELEVATION
"'V
T 1
1 1
1 1
1 I
1 I
1 I
1 I
1 I
[ ----I
I
I
I
j
BEAM MAIN REINFORCEMENT
I I 7
~.... ~ J.
J
SEE NOTE 1
~
PLAN
8
....=:
- NOTES:
- 1. FOR ANTIC RACK BARS AT THE CORNER OF L JUNCTION USE T12 - 250 c/c (MIN.) OR
IF BEAM DEPTH GREATER THAN 750mm. USE ANTICRACK BARS AS SPECIFIED ON BEAM
DETAIL DRAWING.
-
-or
I
-0-'-
I --1
-
'"0r--
/\\
ROOF BEAM -0 ROOF BEAM
'-~
,
I '"r--:
fi\-'--
BINDERS WITH
SPACING::;; 200mm
BINDERS WITH ~ (SEE DETAIL DRG)
SPACING ::;; 200mm
(SEE DETAIL DRG) COLUMN BAR COLUMN BAR
~~ ~~
U1 U1
0::: 0:::
W W
a a
z z
iIi iIi
-,--- -,---
I I
Q>- r- GREATER THAN 75mm Q>-
:s§E
w
USE BENT BAR AND
LESS THAN OR
:s§E
w
-' DOWEL -'
x
I
- W- EQUAL TO 75mm,
USE CRANKED BAR ~ f--
-
x
r--
< [ --H
L--I
r- -I-
-'
~
-0
'"0r--
/\\
-'
~ FLOOR BEAM I FLOOR BE" I
I
L--..
-'--
BINDERS WITH
SPACING ::;; 200mm
BINDERS WITH ~ ~r- r- DOWEL (SEE DETAIL DRG)
SPACING::;; 200mm
-'-
(SEE DETAIL DRG) COLUMN BAR - ~
~ f-- COLUMN BAR ;:::.----' ~
U1 U1
COLUMN - BEAM
0:::
w
a CONDITION X a
0:::
w
z z
-,--- iIi iIi -,---
I GENERAL ~ ( H/4 - LAP LENGTH/2 ) I
Q>- Q>-
:s§E
w "STRONG COLUMN
:s§E
w
- I--
-'
- WEAK BEAM" 0 -
-'
I--
x f-- COLUMN BAR COLUMN BAR x
- r---
I
BINDERS WITH BINDERS WITH
<SPACING::;; 200mm-
(SEE DETAIL DRG) -1
-
FLOOR BEAM FLOOR BEAM
'--
- r- SPACING::;; 200mm
(SEE DETAIL DRG) f
COLUMN
BASE Y L
U1
0:::
*3T10 BINDERS- w
a
z
GENERAL 0 TAL
U1
(SEE NOTE 3) iIi ~ LESSER OF 0:::
w
OR FIXED ~ (H1/4-LAP LENGTH/2) (TAL+D/2) AND a
AS PER DETAIL z
0 (TAL +8 BAR DIA) iIi
0 DRAWING
-==- I
-,--
a
BLINDING LAYER
25
32
T1 0 - 135
T12 - 150
>-
-I-
- - TRANSFER BEAM OR FOUNDATION BEAM 0
NOTES: 40 T12 - 135
U')
r--
OR PILE CAP OR FOOTING ci a
1. FOR ARRANGEMENT OF BEAM REINFORCEMENT 11\
-
IN EXTERIOR COLUMN AND BEAM JUNCTION ,-- --
AT ROOF LEVEL REFER TO DRAWING No. SD/018.
~
0
~
-::
COLUMNS appraved date STRU. ENGG. BRANCH
- AD(SE) W.W. LI MAR., 2012 ARCH. SERVICES DEPT.
a 'I 'I I I I Iso
I I LESSER ( 0.5h OR 80b1 ) + TAL
I
BEAM BAR (01) OF DIA = 01,1 1 I
-
I
.' (
J ROOF BEAM
(02) "1:>
,...
U')
ci
A\
I
I
I
1--H+---I--1I---f--
-~
BINDERS WITH
SPACING EO 200mm
(SEE DETAIL DRG)
BEAM BAR OF DIA = £Ib2 J I ~ 0.75h I
+
II 1 ....... 1 .r:
I .§, I
U')
-'- .8--....
L
I I
I I
114---,------t~- COLUMN BAR (02) OF DIA = 0c
I hi J
f,,--1
COL~MN
I
FIG. 14.1 ROOF BEAM & EXTERIOR COLUMN JUNCTION
- TYPICAL DETAIL (I)
TLL
-
I : COLUMN BAR (02) OF DIA = £Ie
- I
.1
-
COL~MN
-
Q n
~ .", ~
.", CD
"'til' n
e 7'C'
2 ~
Co
:t
~
:z
CO>
(I)~ ~
0 3. HARDCORE SHALL BE OF SUITABLE MATERIAL COMPLYING WITH CLAUSE 3.01{vi) OF THE GENERAL
~G") co SPECIFICATION OR GRADE 200 RECYCLED ROCK FILL AS SPECIFIED.
oF>
IiJto
ii
c~ > :<
FIG. 15.1 TYPICAL DETAIL OF 100 THICK GROUND SLAB ON GRADE
~Q z n
..
;-. Q
~ ii"
Q.
o-~
Z01 a
o_
G)~~ J-
~nc 2
CII
STEEL FABRIC REINFORCEMENT AT TOP
(BS4483 A193 3.02 kg/sq. m)
f"Tl"'~ WITH 300mm LAP MIN. WHERE REQUIRED.
G)~ 20 x 12 APPROVED POLYSULPHIDE /
:::Or-
o POLYURETHANE JOINT SEALANT
Co
z." ONE LAYER OF 65-80 pm
0
POLYTHENE SHEET lWO COATS OF BITUMINOUS PAINT APPROVED POLYETHYLENE FOAM
en WITH 150mm LAP MIN. JOINT FILLER
~
Q n
"0
"0 if
j ~ n
l:"
<>..
I ("')
~
~
z
C')
Q 0 0
~ -0 ':r 0 I I
'in' -0 CD N
0
.D ~ If --=-=-_L-1_~
t (") a.
~ ;-.
c 0
==
z:
c;,
o
n
(/)!Z! 3. HARDCORE SHALL BE OF SUITABLE MATERIAL COMPLYING WITH CLAUSE 3.01 (vi) OF THE GENERAL
~
~S
(")
. '" -a. SPECIFICATION OR GRADE 200 RECYCLED ROCKFILL f.S SPECIFIED.
&Jm
o~ > ~
FIG. 15.3 lYPICAl DETAil OF 200 THICK GROUND SLAB ON GRADE
~Q z co
~ g
~ Ii"
100
O(",)fTI:< ..,Q.
Z»~'"O 0
::OfTI- ::E
..,s· KERB (IF ANY)
G')~::o~
?2 z, $
OA» ii" Eo
fTI '0 CONTRACTION JOINT
G"')O~ ~::I:
::0:;:0» ~ ::::el5 EXPANSION
0-- :c: 8~
c<, "'I •
Z~O ~ -~ ~ CONTRACllON J~NT LONGITUDINAL JOINT
0):>'1 a:::
(/)~
5
~
..... Eo
-.... s;:~
CD 0 SINGLE LAYER OF STEEL FABRIC
~ 0 ~::I:
i!=
CI
::::el5 REINFORCEMENT TO BS 4483
g WITH 450mm LAP MINIMUM DIRECTION OF TRAFFIC
e ~ 83:'
N .
(")
(SEE TABLE 7 FOR MESH TYPE)
E; Q n -~
VI ;r
"0
Ul "0 CD
..cJ. -S n
0
~
a
< C") CD
CD Q.
""
~ Q. ~
C ~
0 0
:z
<V 20000 MAX. 20000 MAX. 20000 MAX.
.. N
0 60000 MAX•
-
~ ~
~
NOTES:
t; 1. DRAWINGS No. SD/022 TO SD/026 ARE NOT APPLICABLE TO WORKS
c... c...
C c THAT WILL BE HANDED OVER TO HIGHWAYS DEPARTMENT.
F< Q. F< 'Q.
uo Q Q
0
8 CD CD 2. CONCRETE TO BE GRADE 30/20.
3 00
3
-~ - MAX. SLAB WIDTH BETWEEN
STEEL MESH
Q. LONGITUDINAL JOINTS, 3. LONGITUDINAL JOINTS SHOULD BE PROVIDED SO THAT SLABS ARE NOT WIDER THAN
a TO BS 4483
~.
'B' THE MAX. WIDTH IN TABLE 7.
~il '"
:::I
.::t:c
. ? C503 4. EVERY THIRD JOINT IN THE TRANSVERSE DIRECTION SHOULD BE AN EXPANSION JOINT,
4.5 m
(/)rr1
(4.34 kg/sq. m) THE REMAINDER BEING CONTRACTION JOINTS.
J'T1z (/)
~C') 8503
op 6.0 m 5. CONTRACTOR IS REQUIRED TO SUBMIT LAYOUT OF JOINTS FOR PSE'S APPROVAL PRIOR
~ (5.93 kg/sq. m) TO CONSTRUCTION OF THE EXTERNAL SLABS ON GRADE.
mm """"
:t ~~ 6. GRANULAR SUB-BASE MATERIAL REFER TO TABLE 8 ON DRG No. SD/026.
z CJ) TABLE 7
'"0 ~2 ..,0
)(
~ 7., THE INSITU FIELD DENSITIES OF COMPACTED MATERIALS BENEATH THE SUB-BASE
Yl ii"
<0 SHALL BE AS INDICATED ON SECTIONS ON DRAWINGS No. SD/023 TO SD/025.
'"
L
100
C-
os;s=<
Z::::o ""0 0
::IE
f'T1 - 5'
G">~::::oS; IC
~ ~r- $
OAr- co
f'T1 0
G">O~ ONE LAYER OF 125 ).Jm POLYTHENE SHEET 25 x 15 SEAUNG GROOVE SAWN OR WET FORMED AT A POSITION VERTICALLY
::::0:::0> WITH 150mm LAP MIN. WHERE REQUIRED. ABOVE THE CRACK-INDUCER TO WITHIN A TOLERANCE OF ±10mm
0--
C<r-
Z~O STEEL FABRIC REINFORCEMENT APPROVED POLYSULPHIDE /
0»:'1
(j)~ ( SEE DRG No. SD/022 ) POLYURETHANE JOINT SEALANT
~ »
co Z
0 0
."
g:
e
> 0 0
0 ~ ~
"0 350
Vi' "0 CD
.0 ., -S 0
0 ~
< (") CD
CD a.
a. ~
:e
0
z:
G")
25mm DIA 650mm LONG MILD STEEL DOWEL BARS PREFORMED PVC TIGHT FITTING
AT MID-DEPTH AND AT 300mm CENTRES DOWEL SLEEVE
~ SUB-BASE
t;
"- "- BOTTOM CRACK-INDUCER ( OF TIMBER, STEEL OR SYNTHETIC MATERIAL )
c: c:
F< a. F< a. SECURELY FIXED TO THE BASE. THE COMBINED DEPTH OF DISCONTINUITY
g; 0 0 PROVIDED BY THE CRACK-INDUCER AND THE SEALING GROOVE AT THE TOP
§ CD CD
3 - ~ - OF THE SLAB SHOULD BE AT LEAST 1/4 OF THE THICKNESS OF THE SLAB
3 o
o
<0
C- RELATIVE COMPACTION ~ 98%
O
::IE SEE GS CLAUSE 3.19 (iv) & (v)
5'
IC
::l
.Xc:: ?
~~.
(/)f'T1
f'TlZ (j)
~Ci) 0
...........
n P 0
~
~ttI <.....a
FIG. 16.2 SEC. A-A DETAIL OF CONTRACTION JOINT
:t O~
f'Tl IN EXTERNAL DRIVEWAY AND CAR PARKING AREAS
N n Z en
(')
0 ~X ;-t 0
)C
Yl co
N
<0
L
100
a.
..,
0
~
~~8~
G')-or'Tl(=5 5'
\0
~»:::o»
:::oZ,- - ONE LAYER OF 125 pm POLYTHENE SHEET
$ WITH 150mm LAP MIN. WHERE REQUIRED. - APPROVED SEALING STRIP GLUED TO EDGE OF FIRST SlAB
OA» (j)
r'Tl '-0 CAST PRIOR TO POURING THE SECOND SlAB
G')O~
;:0:::0»
0-- - STEEL FABRIC REINFORCEMENT
C~,- ( SEE DRG No. SD/022 )
Z 0
0>"
U')~
'0 00 ~ s: - , ~"-r-.~ 10
C'oI
0
~ r- - -- _L.. -- -- - - - t2L.
g
e
E IfYP
---------
>- Q ()
c ~ ::T
til" CD
c ()
7':'
""d "S-
<:> < ("") CD
~ CD a. I 75 75 I
:== a. ;-t I I '-12mm DIA. MILD STEEL DOWEL BARS, 1.1m IN LENGTH
:e 150mm LONG PREFORMED PVC TIGHT FITTING SLEEVE- AND SPACED AT 600mm CENTRES AT MID-DEPTH
0 0
:z
C")
" N
- <:> /
~ SUB-BASE
~
I
~
c... c...
c: c:
F< 0-
Q
F< a.
g; N Q
CD CD
3 ~ -~ -
3 RELATIVE COMPACTION ~ 98%
a. SEE GS CLAUSE 3.19 (iv) & (v)
a
~.
::l
\C!
~~ ::J
.:I:c
. ?
~52 (/)
~G") I::'
o!" a N
VJm ~
FIG. 16.3 SEC. 8-8 DETAIL OF LONGITUDINAL JOINT
~ o~
N "'0 IN EXTERNAL DRIVEWAY AND CAR PARKING AREAS
z III
a ~:I: n
~ 0
)( (j)
\I'
N
co·
L
100
O<JITI:< n.
..,
:::u _
:Z>~""O 0
:IE
5·
G')~:::u~ .a
~:::u:z. ........ :-- ONE LAYER OF 125 pm POLYTHENE SHEET - 25 x 15 SAWN OR WET FORMED GROOVE
CIA> co WITH 150mm LAP MIN. WHERE REQUIRED.
ITI 'CI
G")CI~
:::u:::u>
0-- ,- STEEL FABRIC REINFORCEMENT APPROVED POLYSULPHIOE /
c::<' ( SEE ORG No. SO/022 ) POLYURETHANE JOINT SEALANT
:z~O
0::J>:"T'1
c.n~
... »
... CD Z BOND BREAKER ______ l ~ ~~ ~I
~ CI - ...' - "",0 20 _ _ ...l
g
-- _ 50 0
~ 350 ITYP 0 300 ,25 L
I
0 ("') 0
I I
E; "C VI ':T
til "C CD
5 ., -S 0
0 0 71:"
::e < (") CD
CD a.
;:e a. ;-t A~ L
HOLES DRILLED IN THE FILLER TO GIVE J -1 25 ~ PREFORMED PVC TIGHT FiTTiNG
C ::e
0
<5 :z A DOWEL BAR SLEEVE A ·PUSH FIT" ~ DOWEL SLEEVE
G")
~ v
-.. ' - 25mm DIA 650mm LONG MILD STEEL DOWEL BARS
AT MID-DEPTH AND AT 300mm CENTRES.
~ SUB-BASE HALF LENGTH PAINTED WITH BOND PREVENTING COMPOUND.
~
I
¥ '-APPROVED POLYETHYLENE FOAM
~ JOINT FILLER
c... c...
c:: c::
E< a. F< a.
UI 0 0
0 '" '"
8 CD @ CD
3 00
- -
3 8
co
n.
a RELATIVE COMPACTION ~ 98%
!.
::J
IQ SEE GS CLAUSE 3.19 (iv) & (v)
~3a :::>
::I:c::
. . ?
U)ITI
ITIz U)
~8
("')
. ~
C>
mm 01
'" FIG. 16.4 SEC. C-C DETAIL OF EXPANSION JOINT
~ o~
ITI("') IN EXTERNAL DRIVEWAY AND CAR PARKING AREAS
z (Jl
0 0
'".... ~::I: ;-. 0
)(
~ co
'"co
L
RANGE OF GRADING
37.5 mm 85 tv 100
20 mm 60 tv 85
10 mm 40 tv 70
5 mm 25 tv 45
600 JJm 8 tv 22
75 JJm o N 10
b. THE MATERIAL PASSING THE B.s. SIEVE 425 JJm WHEN TESTED IN ACCORDANCE WITH
- BS 1377 SHALL BE NON-PLASTIC.
AD(SE)
/ I A'
~W.=W.~U~-=ffof/_IoLL..-4-_-If--_
date
JULY, 2008
STRU. ENGG. BRANCH
ARCH. SERVICES DEPT.
M 210 x 29j~
1 : 1 SCALE BAR