21-00-00-18100-00-A / SHEET 1/1 - Air Bleed Display

3 4 5

BLEED

24 C 24 C
6
C H C H
50 C RAM 50 C 7
2 AIR
LO HI LO HI
1
ANTI ANTI
ICE ICE
30 PSI GND PSI 30
160 C C 160
APU
1 2
IP HP HP IP

1. PACK FLOW CONTROL VALVE 4. RAM AIR INLET VALVE


DISPLAYED IN GREEN = VALVE OPEN DISPLAY IN GREEN = FULLY CLOSED

DISPLAYED IN AMBER = VALVE NOT FULLY DISPLAY IN AMBER = FULLY OPEN


CLOSED AND DISAGREE
DISPLAY IN AMBER = VALVE IN TRANSFER
DISPLAYED IN GREEN = VALVE CLOSED
XX (AMBER) = VALVE FAULT
DISPLAYED IN AMBER = VALVE CLOSED
AND DISAGREE
5. PACK OUTLET TEMPERATURE
XX (AMBER) = VALVE POSITION FROM TEMP IS DISPLAYED IN GREEN WHEN <90 C
SDAC NOT VALID
XX (AMBER) TEMP VALUE NOT AVAIL
2. PACK FLOW
PACK FLOW IS DISPLAYED IN GREEN 6. TEMPERATURE CONTROL VALVE
= NORMAL POSITION IS DISPLAYED IN GREEN
PACK FLOW DISPLAYED IN AMBER C (COLD) = VALVE IS CLOSED
= FULLY CLOSED
XX (AMBER) PACK FLOW VALVE (OR CAB H (HIGH) = VALVE IS OPEN
PRESS/CAB ALT) NOT VALID XX (AMBER) VALVE POSITION NOT VALID

3. AIR DUCT SUPPLY 7. PACK COMPRESSOR OUTLET TEMPERATURE


DISPLAY IN GREEN TEMP DISPLAYED IN GREEN = TEMP IS IN RANGE
TEMP DISPLAYED IN AMBER = TEMP 230 C
XX (AMBER) TEMP NOT AVAIL

N_MM_210000_0_AJM0_01_00

Figure 21-00-00-18100-00-A / SHEET 1/1 - Air Bleed Display


** ON A/C ALL