Professional Documents
Culture Documents
. . . . . . EQUIPMENT LIST
GAS GATHERING STATION
Glass flaked
Reinforced
Internal sacrificial cathodic protection to be provided against lining failure. Duplex SS
2 Cone Roof 1 334-T-001 Produced Water Storage Tank 732 10500 x 9600 180/2.5 -15/82 0.07 8/45 KCS 1.5 Epoxy no yes no 49.1
Internals.
(GFRE)
(full)
Notes
1) Equipment weights are indicative only for details refer vendor drawing / equipment drawings
2) Final motor rating for all pumps, compressors and packages items to be confirmed by mechanical based on ve
3) Final dimensions for all pumps to be confirmed by mechanical based on vendor information.
4) Skid dimensions are indicative only . Please refer vendor drawings for details.
Project : AL-SHAER GGS REHABILITATION PROJECT
Client : EBLA PETROLEUM COMPANY
Sour
Design Design Operating Design Operating Corrosion
Service Equipment Weight
No Type Quantity Tag Description Material Duty Allowance Lining Cladding Insulation Remarks Rev.
Capacity Pressure Pressure Temp. Temp. NACE
(MMSCFD) (barg) (barg) (°C) (°C) (mm) MR0175 MT
Air Compressor
Package (incl. Air compressor and related
2 Rotary Screw 2 (1W+1S) 325-X-001 Hold Hold Hold Hold Hold Hold Hold Hold Hold Hold 0
325-K-001 A/B) accessories
NOTE 6
Instrument Air
3 instrument Air Dryer 2 (1W+1S) 325-X-002 A/B DryerPackage Hold Hold Hold Hold Hold Hold Hold Hold Hold Hold Hold 0
NOTE 7
SS316L Stainless steel stack, 24" ID 30m high with
Flare Package Process:
(Stack)/ CS HP Flare Package, Vertical baffle seal, tip and 3 pilots, package also
6 Flare 1 331-X-001 (incl 331-B-001 106230 Kg/hr 3.5 0.1-0.5 175/-62 Tip: 120.57 no 10 Approx. 0
(Ignition Stack Includes flare tip Ignition panel. Smokeless
Flare Stack) By Vendor
Panel) operation (blowers/snuffing) not required.
Notes:
1) Equipment weights are indicative only for details refer vendor drawing / equipment drawings
2) Final motor rating for all pumps, compressors and packages items to be confirmed by mechanical based on vendor information
3) Final dimensions for all pumps to be confirmed by mechanical based on vendor information.
4) Skid dimensions are indicative only . Please refer vendor drawings for details.
Project : AL-SHAER GGS REHABILITATION PROJECT
Client : EBLA PETROLEUM COMPANY