You are on page 1of 234

CAT.

EUS11-83 B -UK

5 Port Solenoid Valve


Power Consumption
With Power Saving Circuit

SY Series
Improved pilot valve
Pilot valve cover is stronger using stainless steel.
Mounting thread is also reinforced from size M1.7 to M2.

 Flow Characteristics
Flow characteristics
Series
C [dm3/(s·bar)] b Cv Q [l/min(ANR)]
SY3000 1.1 0.28 0.29 276
SY5000 2.8 0.37 0.90 746
SY7000 4.5 0.28 1.4 1130
Cover (stainless steel) SY9000 10 0.29 2.5 2527
Cylinder Speed Chart
Use as a guide for selection.
Please confirm the actual conditions with SMC Sizing
Body Ported Program.
Bore size
Series CJ2 Series CM2 Series MB/CA2 Series CS1
Average Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50% Load rate: 50% Load rate: 50% Load rate: 50%
speed
Stroke 60 mm Stroke 300 mm Stroke 500 mm Stroke 1000 mm
(mm/s)
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
800
700 Perpendicular,
600 upward actuation
500
SY3120-C6 400
300
Horizontal actuation
200
100
0
800
700
600
500
SY5120-01 400
300
200
100
0
800
700
600
500
SY7120-02 400
300
200
100
0
800
700
600
500
SY9120-03 400
300  
200
100
0

Base Mounted
Bore size
Series CJ2 Series CM2 Series MB/CA2 Series CS1
Average Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series Load rate: 50% Load rate: 50% Load rate: 50% Load rate: 50%
speed
Stroke 60 mm Stroke 300 mm Stroke 500 mm Stroke 1000 mm
(mm/s)
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180 ø200
800
700 Perpendicular,
600
500 upward actuation
SY3140-01 400
300 Horizontal actuation
200
100
0
800
700
600
500
SY5140-02 400
300
200
100
0
800
700
600
500
SY7140-03 400
300 
200 
100
0
800
700
600
500
SY9140-04 400
300  
200  
100
0
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%
∗ The histograms with  marked are the case when piping is done by using steel.

Conditions Conditions
Body ported Series CJ2 Series CM2 Series MB/CA2 Series CS1 Base mounted Series CJ2 Series CM2 Series MB/CA2 Series CS1
Tubing bore x Length T0604 x 1 m – Tubing bore x Length T0604 x 1 m –
SY3120-C6 Speed controller AS2051F-06 – SY3140-01 Speed controller AS3001F-06 –
Silencer AN120-M5 – Silencer AN110-01 –
Tubing bore x Length T0604 x 1 m T0806 x 1 m – Tubing bore x Length T0604 x 1 m T0806 x 1 m –
SY5120-01 Speed controller AS3001F-06 AS3001F-08 – SY5140-02 Speed controller AS3001F-06 AS3001F-08 –
Silencer AN101-01 – Silencer AN101-01 –
Tubing bore x Length T0604 x 1 m T1075 x 1 m – Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m –
SY7120-02 Speed controller AS3001F-06 AS4001F-10 – SY7140-03 Speed controller AS3001F-06 AS4001F-10 –
Silencer AN110-01 – Silencer AN200-02 –
Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
SY9120-03 Speed controller AS3001F-06 AS4001F-10 AS4001F-12 SY9140-04 Speed controller AS3001F-06 AS4001F-10 AS4001F-12
Silencer AN200-02 AN202-02 Silencer AN200-02
Conditions [When using SGP (steel pipe)] Conditions [When using SGP (steel pipe)]
Body ported Series CS1 Base mounted Series CS1
Tubing bore x Length SGP10A x 1 m Tubing bore x Length SGP10A x 1 m
SY9120-03 Speed controller AS420-03 SY7140-03 Speed controller AS420-03
Silencer AN200-02 Silencer AN300-03
Tubing bore x Length SGP15A x 1 m
SY9140-04 Speed controller AS420-04
Silencer AN400-04
Front matter 1
Valve Variations

Note 1)
Actuation Voltage Electrical entry

Light/surge voltage suppressor


2 position 3 position DC AC

M plug connector
Sonic 100 V

L plug connector
24 V 50/60 Hz Note 4)
Series conductance

M8 connector
Pressure center
12 V 110 V

DIN terminal
Closed center
C [dm3/(s·bar)]

Exhaust center
50/60 Hz
6V

Grommet
200 V
{ 4/2→5/3
}

Double
5V 50/60 Hz

Single
(A/B→EA/EB) 3V 220 V
50/60 Hz

P.1
SY3 20 0.65
Body ported

SY5 20 2.4

SY7 20 3.3

SY9 20 8.6
P.19
SY3 40 1.1
Base mounted

SY5 40 2.8

SY7 40
A

4.5
B

PE

SY9 40 10

Manual P, EA, EB
port size A, B port size Valve option
override

Oil resistant, Other than designated turbine oil,

Low pressure specifications


Push-turn locking lever type
Push-turn locking slotted type

Vacuum specifications
Non-locking push type

Interface regulator
One-touch fitting Note 3)
Exhaust throttle

Enclosure IP65
Series

External pilot
M5 1 8 1 4 3 8 1 2 M5 1 8 1 4 3 8 1 2
Bracket

C4 C6 C8 C10 C12 N3 N7 N9 N11

SY3 20
Body ported

SY5 20
SY7 20 (EA, EB) (P)
External External External DIN
Pilot Pilot Pilot terminal
(Note 2) (Note 2) (Note 2) M8
connector
SY9 20
SY3 40
Base mounted

SY5 40
SY7 40 Sub-plate External External External DIN
pilot pilot pilot terminal
M8

SY9 40
connector

Note 1) All AC voltage models have built-in surge voltage suppressor.


Note 2) Body ported external pilot style (made to order) is not available for DIN terminal.
Note 3) Only available for DIN terminal and M8 connector.
Note 4) SY3000 does not have a DIN terminal which can be connected to a manifold.

Front matter 2
Manifold Variations

Wiring
Connection Common specifications

connector (25 pins)


Flat ribbon cable (20 pins)

Plug-in type flat ribbon

Serial transmission
Plug-in type D-sub

Plug-in type terminal

Negative common
Valve

cable (26, 20, 10 pins)


Individual wiring

Positive common
Flat ribbon cable

block (9, 18 pins)


Series
Manifold Variations

connector box

PC wiring
(26 pins)
5 port

unit
Bar stock type
Individual wiring Type 20 SY3 20
 Direct piping to the main unit of
a valve. Combination of
–+
–+
–+
–+
B
E
P. 37 SY5 20
SY7 20
P

different fittings is possible.


A
E

Bar stock type


Flat ribbon cable
Type 20P SY3 20
P. 47 SY5 20
Body ported

 A 26 pins MIL connector


B

permits One-touch wiring of


E

In common
SY7 20
P
A
E

external cables in a bundle.

Stacking type
Individual wiring
–+

–+
Type 23 SY9 20
P. 43
–+

–+

 Manifold stations can be increased.


EB

EA

Stacking type
Flat ribbon cable
Type 23P SY9 20
 Manifold stations can be increased. P. 53 In common
Cassette type
Individual wiring
Type 60 SY3 60
P. 59 SY5 60
R

 Size and weight reduced by –+


–+
P

eliminating the manifold base


SY7 60
Compact bar stock type
Individual wiring –+
–+
Type 41 SY3 40
 The base mounting facilitates maintenance P. 79 SY5 40
–+
–+

EB

after valves are changed.


EA

Compact bar stock type


Flat ribbon cable Type 41P SY3 40
 A 26 pins MIL connector permits one-touch P. 95 SY5 40
EA

In common
P
EB

wiring of external cables in a bundle.


Bar stock type/Common external EXH
Individual wiring
Type 42 SY3 40
 The base mounting facilitates
maintenance after valves are changed.
–+
–+
–+
–+
P. 79 SY5 40
 Vacuum/low pressure combination
SY7 40
EB

P
EA

system is possible.
Bar stock type/Common external EXH 42P SY3 40
Base mounted

Type
Flat ribbon cable
 A 26 pins MIL connector permits one-touch
wiring of external cables in a bundle.
P. 95 SY5 40
In common
SY7 40
EA

 Vacuum/low pressure combination system EB


P

is possible.

Stacking type
Individual wiring
–+

–+

–+
Type 43 SY9 40
P. 89
–+

 Manifold stations can be increased.

Stacking type
Flat ribbon cable
Type 43P SY9 40
 Manifold stations can be increased. P. 103
In common
Stacking type/DIN rail mounted
Individual wiring
–+
–+
–+
–+
–+
Type 45 SY3 40
 Stations can be increased on the DIN rail. Integral
mounting of other electric parts is possible, too.
P. 115 SY5 40
Stacking type/DIN rail mounted
Connector box Type 45- A
NA SY3 40
 Stations can be increased on the DIN rail. The provided
connector box permits one-touch connection of electric cables.
P. 127 SY5 40
Stacking type/DIN rail mounted
Plug-in Type 45 SY3 40
 Stations can be increased on the DIN rail.
 A variety of centralised wiring methods are possible.
P. 135 SY5 40
Standard Option Made to order (Refer to page “Made to Order”.)
Front matter 3
Manifold Variations

Manifold option A, B port size Valve option

Oil resistant (Other than

Different pressure
Vacuum specifications
Individual SUP spacer
Individual EXH spacer

Low pressure specifications


Silencer for One-touch fitting

Interface regulator
Label for block disk

Mixed mounting

Mixed fitting sizes


designated turbine oil)

Exhaust throttle
Built-in silencer
SUP block disk
EXH block disk

IP65 enclosure
Blanking plate

Bundle wiring
External pilot
One-touch fitting
M5 1 8 1 4 3 8

C4 C6 C8 C10 C12 N3 N7 N9 N11 SY3000


SY5000
Note)

Note)

Individual Individual Note)


SUP EXH
interface interface

Individual Individual
SUP EXH
interface interface

Note)
Individual
External External SUP External Individual
pilot pilot block disk pilot EXH

Individual
SUP
External External External Individual
block disk EXH
pilot pilot pilot
Note)
External External Individual SUP Individual SUP
pilot pilot block disk block disk
Note)
External External Individual SUP Individual SUP
pilot pilot block disk block disk
Note)
External External Individual SUP Individual SUP
pilot pilot block disk block disk
Note)

Individual Note)
SUP
interface

Individual
SUP
interface
Note)

Note)

External External Individual External


Note)
pilot pilot SUP pilot
interface

External External Individual External


pilot pilot SUP pilot
interface

Note)
Individual
SUP
External External External Individual
block disk
pilot pilot pilot EXH

Individual
SUP
External External block disk External Individual
pilot pilot pilot EXH
Note)
Individual
SUP
Note)
External External spacer or
block disk
pilot pilot

Individual
SUP
spacer or
External External block disk
pilot pilot

Individual
SUP
spacer or
External External block disk
pilot pilot

Note) When using DIN terminal or M8 connector.


SY3000 does not have a DIN terminal Front matter 4
which can be connected to a manifold.
5 Port Solenoid Valve
Series SY3000/5000/7000/9000
Body Ported
Single Unit Refer to www.smcworld.com for details of
products compatible with overseas standards.

How to Order

SY 5 1 20 5 L 01 -Q
Series Bracket
3 SY3000
-: Without bracket
5 SY5000 A, B port size F1: With foot bracket
7 SY7000 Thread piping
2 position
9 SY9000 Symbol Port size Applicable series single only
M5 M5 SY3000
01 18 SY5000
Coil specifications 02 14 SY7000
Type of actuation 02 14
- Standard SY9000
2 position single With power saving circuit 03 38
T F2: With side bracket
1 (24, 12 VDC only) One-touch fitting (Metric size)
∗ Power saving circuit is not Symbol Port size Applicable series
available in the case of D, C4 One-touch fitting for ø4
SY3000
2 position double DO or W type. C6 One-touch fitting for ø6
C4 One-touch fitting for ø4
2 For DC C6 One-touch fitting for ø6 SY5000
5 24 VDC C8 One-touch fitting for ø8
6 12 VDC C8 One-touch fitting for ø8 ∗ SY9000 has no bracket.
3 position closed center SY7000
V 6 VDC C10 One-touch fitting for ø10
S 5 VDC C8 One-touch fitting for ø8
3
R 3 VDC C10 One-touch fitting for ø10 SY9000
Rated voltage C12 One-touch fitting for ø12
For AC (50 60 Hz)
3 position exhaust center One-touch fitting (Inch size) Thread type
1 100 VAC
Symbol Port size Applicable series - Rc
4 2 200 VAC
N3 One-touch fitting for ø 5 32" F G
3 110 VAC [115 VAC] SY3000
N7 One-touch fitting for ø 1 4" N NPT
4 220 VAC [230 VAC]
N3 One-touch fitting for ø 5 32" T NPTF
3 position pressure center ∗DC specifications of type D and DO is only N7 One-touch fitting for ø 1 4" SY5000 ∗ Except for M5
available with 12 and 24 VDC.
5 N9 One-touch fitting for ø 5 16"
∗AC specification is only available with D,
DO type. N9 One-touch fitting for ø 5 16"
SY7000
N11 One-touch fitting for ø 3 8"
N9 One-touch fitting for ø 16"
5
SY9000
N11 One-touch fitting for ø 3 8"
Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC Manual override
Grommet L plug connector M plug connector DIN terminal Note2) -: Non-locking D: Push-turn locking E: Push-turn locking
G: Lead wire L: With lead wire M: With lead wire MN: Without lead wire D: With connector push type slotted type lever type
length 300 mm (Length 300 mm) (Length 300 mm)
+-
+-

+
– -+

H: Lead wire LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector
length 600 mm

Light/surge voltage suppressor



+
-+ Electrical entry for G, H, L, M, W Electrical entry for D (except SY3000)
- Without light/surge voltage suppressor - Without light/surge voltage suppressor
24, 12, 6, 5, 3 VDC ∗ LN, MN type: with 2 sockets. S With surge voltage suppressor S With surge voltage suppressor
M8 connector ∗ ∗ For DIN terminal of SY3000 series, refer Z With light/surge voltage suppressor Z With light/surge voltage suppressor
WO: Without connector cable to back page 10. R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
∗ DIN terminal type “Y” which conforms to
U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves
EN-175301-803C (former DIN43650C)
∗ Power saving circuit is only available in the "Z" type. there is no “S” option. It is
is also available. For details, refer to
already built-in to the
page 210.
rectifier circuit.
∗ For connector cable of M8 connector,
W: With connector cable refer to back page 12.
Note 1)
∗ Connector M8 type “WA” conforming to
IEC 60947-5-2 standard, is also Note) When placing an order for body ported solenoid valve as a single unit,
available. For details, see page 211. mounting bolt for manifold and gasket are not attached. Order them
Note 1) Enter the cable length symbols in separately, if necessary. (For details, refer to page 56.)
. Please be sure to fill in the
blank referring to back page 13.
Note 2) Except SY3000.

1
SY3000/5000/7000/9000 Body Ported

Specifications

Series SY3000 SY5000 SY7000 SY9000


Fluid Air
Internal pilot 2 position single 0.15 to 0.7
Operating pressure 2 position double 0.1 to 0.7
range (MPa) 3 position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Max. operating 2 Position single, Double 10 5 5 5
frequency (Hz) 3 position 3 3 3 3
Non-locking push type,
Manual override (Manual operation)
Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method Common exhaust type for main and pilot valve
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 150/30
Enclosure Dust proof (∗ DIN terminal and M8 connector: IP65)
∗ Based on IEC60529)
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the
right angles to the main valve and armature in both energised and de-
energised states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz.
Test was performed at both energised and de-energised states in the axial
direction and at the right angles to the main valve and armature. (Values at
the initial period)

Made to Order Solenoid Specifications


(For details, refer to pages 199 through to 213.)

Grommet (G), (H) DIN terminal (D)


L plug connector (L) M8 connector (W)
Electrical entry M plug connector (M)
G, H, L, M, W D
Coil rated DC 24, 12, 6, 5, 3 24, 12
voltage (V) AC 50 60 Hz 100, 110 200, 220
Allowable voltage fluctuation (%) ±10% of rated voltage ∗
Power Standard 0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
consumption (W) DC With power saving circuit 0.1 (With indicator light only)
100 V - 0.78 (With indicator light: 0.87)
110 V - 0.86 (With indicator light: 0.97)
Apparent power [115 V] - [0.94 (With indicator light: 1.07)]
(VA) ∗ AC
200 V - 1.15 (With indicator light: 1.30)
220 V - 1.27 (With indicator light: 1.46)
[230 V] - [1.39 (With indicator light: 1.60)]
Surge voltage suppressor Diode (Varistor is for DIN terminal and Non-polar type.)
Indicator light LED (AC of DIN connector is neon light.)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage
fluctuation range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
12 VDC: –4% to +10%
T type: 24 VDC: –8% to +10%
12 VDC: –6% to +10%
Response Time
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge suppressor)

SY3000 SY7000
Response time (ms) (at the pressure of 0.5 MPa) Response time (ms) (at the pressure of 0.5 MPa)
Type of Without light/surge With light/surge voltage suppressor Type of Without light/surge With light/surge voltage suppressor
actuation voltage suppressor actuation voltage suppressor
Type S, Z Type R, U Type S, Z Type R, U
2 position single 12 or less 15 or less 12 or less 2 position single 31 or less 38 or less 33 or less
2 position double 10 or less 13 or less 10 or less 2 position double 27 or less 30 or less 28 or less
3 position 15 or less 20 or less 16 or less 3 position 50 or less 56 or less 50 or less

SY5000 SY9000
Response time (ms) (at the pressure of 0.5 MPa) Response time (ms) (at the pressure of 0.5 MPa)
Type of Without light/surge With light/surge voltage suppressor Type of Without light/surge With light/surge voltage suppressor
actuation voltage suppressor actuation voltage suppressor
Type S, Z Type R, U Type S, Z Type R, U
2 position single 19 or less 26 or less 19 or less 2 position single 35 or less 41 or less 35 or less
2 position double 18 or less 22 or less 18 or less 2 position double 35 or less 41 or less 35 or less
3 position 32 or less 38 or less 32 or less 3 position 62 or less 64 or less 62 or less

2
Body Ported

Flow Characteristics/Weight
Series SY3000
Port size Flow characteristics Weight (g)
Valve Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) L/M W
1, 5, 3 4, 2 Gro- plug M8
model actuation C (kdm / Q[l/min(ANR)] C (kdm / b Cv Q[l/min(ANR)]
3 3
(P, EA, EB) (A, B) b Cv mmet connector connector
(s·bar)) (s·bar) )
2 Single 171
51 53 57
position Double 0.61 0.44 0.16 0.64 0.45 0.18 181
68 74 82
Closed 137
0.48 0.46 0.13 0.47 0.43 0.13 131
SY320 center
--M5 3 Exhaust M5 x 0.8 129
0.47 0.41 0.13
0.47 0.42 0.13 130 (0.44) (0.37) (0.12) (117) 71 76 84
position center
Pressure 0.50 0.48 0.15 145
(0.41) (0.35) (0.11) (108) 0.47 0.43 0.13 131
center
2 Single 0.72 0.29 0.18 182 0.64 0.34 0.17 167
60 63 67
position Double 78 83 91
Closed C4 0.59 0.28 0.15 148
center 0.59 0.30 0.15 150
SY320
One-
--C4 3 Exhaust M5 x 0.8 0.42 0.34 0.11 110
touch fitting 0.63 0.35 0.16 166 81 86 94
position center for ø4 (0.41) (0.37) (0.11) (109)
Pressure 0.76 0.42 0.21 210
center (0.46) (0.34) (0.12) (120) 0.59 0.29 0.15 149
2 Single 193 176
56 59 63
position Double 0.76 0.30 0.19 0.65 0.39 0.17 74 79 87
Closed C6 0.76 0.55 233
center 0.24 0.60 0.33 0.16 156
SY320 One-
--C6 3 Exhaust touch fitting 0.65 0.32 0.64 0.31 0.17 164
0.16 167 (111) 77 82 90
position center for ø6 (0.42) (0.36) (0.11)
Pressure 0.77 0.34 0.21 201
center (0.49) (0.43) (0.15) (136) 0.61 0.34 0.16 159
Note) ( ): denotes normal position.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

Series SY5000
Port size Flow characteristics Weight (g)
Valve Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) L/M W
1, 5, 3 4, 2 Gro- plug DIN M8
model actuation C (dm3/ C (dm3/
(P, EA, EB) (A, B)
(s·bar) ) b Cv Q[l/min(ANR)] (s·bar) ) b Cv Q[l/min(ANR)] mmet connector terminal connector
2 Single 70 72 93 76
position Double 1.9 0.35 0.49 499 2.4 0.39 0.61 648
88 93 135 101
Closed 473 473
center 1.7 0.43 0.45 1.8 0.35 0.46
SY520 18
--01 3 Exhaust 2.5 0.32 0.59 644
position center 1.5 0.44 0.41 420 (417) 93 98 140 106
(1.5) (0.43) (0.40)
Pressure 2.2 0.46 0.61 626
(287) 1.8 0.38 0.46 483
center (0.91) (0.58) (0.28)
2 Single 209 285
94 96 117 100
position Double 0.75 0.43 0.20 0.85 0.64 0.30
111 117 159 125
Closed C4 0.74 201 263
SY520 center 0.40 0.19 0.84 0.57 0.28
One-
--C4 3 Exhaust 0.84 0.64 0.30 281
position center touch fitting 0.75 0.36 0.19 198 117 122 164 130
for ø4 (0.84) (0.53) (0.27) (253)
Pressure 0.78 0.44 0.21 219
(189) 0.84 0.57 0.27 263
center 1 (0.71) (0.37) (0.18)
8
2 Single 389 533 88 91 112 95
position Double 1.5 0.33 0.33 2.0 0.37 0.52
106 111 153 119
Closed C6 333 412
center 1.3 0.31 0.33 1.6 0.32 0.39
SY520 One-
--C6 3 Exhaust touch fitting 1.3 1.8 0.35 0.44 473
0.33 0.33 337 (373) 111 116 158 124
position center for ø6 (1.4) (0.37) (0.35)
Pressure 1.7 0.31 0.42 435
(229) 1.7 0.33 0.44 441
center (0.80) (0.47) (0.23)
2 Single 458 581
80 82 103 86
position Double 1.9 0.21 0.45 2.3 0.29 0.57
98 103 145 111
Closed C8 404 456
center 1.6 0.29 0.39 1.7 0.38 0.46
SY520 One-
--C8 3 Exhaust touch fitting 1.4 2.0 0.37 0.52 533
position center 0.38 0.39 375 (1.5) (0.41) (0.43) (411) 103 108 150 116
for ø8
Pressure 2.2 0.32 0.56 567
(448) 1.8 0.41 0.50 493
center (1.6) (0.44) (0.44)
Note) ( ): denotes normal position.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

3
SY3000/5000/7000/9000 Body Ported

Series SY7000
Port size Flow characteristics Weight (g)
Valve Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) L/M W
1, 5, 3 4, 2 Gro- plug DIN M8
model actuation C (dm3/ C (dm3/
(P, EA, EB) (A, B)
(s·bar) ) b Cv Q[l/min(ANR)] (s·bar) ) b Cv Q[l/min(ANR)] mmet connector terminal connector
2 Single 101 104 125 108
position Double 4.1 0.23 0.93 999 3.3 0.33 0.81 855
120 125 167 133
Closed 742 644
center 2.9 0.31 0.70 2.4 0.38 0.63
SY720 14
--02 3 Exhaust 3.4 0.35 0.82 893
2.5 0.39 0.65 675 (563) 128 133 175 141
position center (2.1) (0.38) (0.54)
Pressure 4.3 0.23 0.97 1048
(618) 2.2 0.39 0.58 594
center (2.4) (0.32) (0.61)
2 Single 1 (P) 794 852
107 110 131 114
position Double Port 3.2 0.26 0.77 3.2 0.37 0.82
126 132 174 140
Closed 1 4 C8 637 614
SY720 center 2.6 0.24 0.63 2.4 0.31 0.62
One-
--C8 3 Exhaust 5, 3 2.6 0.42 0.70 718
position center (EA, EB) touch fitting 2.4 0.25 0.57 592
(1.9) (0.46) (0.56) (541) 134 140 182 148
for ø8
Pressure port 3.3 0.28 0.78 829
2.2 0.34 0.60 574
center 1 8 (2.4) (0.22) (0.57) (581)
2 Single 943 835
103 105 126 109
position Double 3.8 0.26 0.86 3.2 0.34 0.82
122 127 169 135
Closed C10 2.8 699 578
center 0.27 0.67 2.4 0.21 0.59
SY720 One-
--C10 3 Exhaust touch fitting 2.5 2.7 0.38 0.70 724
0.25 0.59 616 (536) 130 135 177 143
position center for ø10 (2.0) (0.38) (0.56)
Pressure 3.8 0.25 0.89 937
(614) 2.3 0.38 0.61 617
center (2.4) (0.31) (0.61)
Note) ( ): denotes normal position.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

Series SY9000
Port size Flow characteristics Weight (g)
Valve Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) L/M W
1, 5, 3 4, 2 Gro- plug DIN M8
model actuation C (dm3/ C (dm3/
(P, EA, EB) (A, B) b Cv Q[l/min(ANR)] (s·bar) ) b Cv Q[l/min(ANR)] mmet connector terminal connector
(s·bar) )
2 Single 241 244 265 248
position Double 7.0 0.33 1.7 1815 7.6 0.35 2.0 1997 260 266 308 274
Closed
center 6.7 0.37 1.7 1784 6.4 0.34 1.6 1670
SY920 14
--02 3 Exhaust 8.3 0.41 2.2 2274
position center 6.4 0.36 1.6 1693 (4.1) (0.27) (0.91) (1023) 284 290 332 298
Pressure 8.0 0.27 1.8 1997 6.5 0.22 1.4
center (3.2) (0.34) (0.76) 1575
(835)
2 Single 8.0 0.29 1.9 8.0 0.33 2.0
236 239 260 243
position Double 2021 2074 255 261 303 269
Closed
SY920 center 7.9 0.33 1.9 2048 6.6 0.27 1.6 1647
38
--03 3 Exhaust 8.7 0.34 2.2 2270
position center 8.0 0.33 1.9 2074 (8.3) (0.40) (2.3) (2258) 279 285 327 293
Pressure 8.9 0.34 2.2 2323 6.5 0.25 1.5
center (3.3) (0.40) (0.82) 1603
(898)
2 Single 293 296 317 300
position Double 4.3 0.28 0.96 1080 7.1 0.32 1.7 1829 312 318 360 326
Closed C8
center 4.3 0.31 0.99 1100 6.1 0.28 1.4 1532
SY920 14 One-
--C8 3 Exhaust touch fitting 4.3 0.3 7.4 0.36 1.9 1957
position center 0.99 1093 (3.8) (0.29) (0.86) (960) 336 342 384 350
for ø8
Pressure 4.4 0.35 1.0 1156 2.1 0.41 0.53
center (3.2) (0.26) (0.71) 575
(794)
2 Single 279 282 303 286
position Double 6.1 0.28 1.4 1532 7.9 0.33 1.9 2048
298 304 346 312
Closed C10 5.9 0.30
center 1.4 1500 6.5 0.26 1.5 1612
SY920 One-
--C10 3 Exhaust touch fitting 5.8 0.25 8.4 0.33 2.0 2178
position center 1.3 1430 (4.1) (0.27) (0.93) (1023) 322 328 370 336
for ø10
Pressure 6.3 0.29 1.5 1592 6.4 0.25 1.5
center (3.2) (0.29) (0.72) 1578
(809)
2 Single 265 268 289 272
position Double 7.0 0.25 1.6 1726 8.6 0.41 2.2 2356
284 290 332 298
Closed C12 6.9 0.24
center 1.6 1691 7.0 0.33 1.7 1815
SY920 One-
--C12 3 Exhaust touch fitting 6.6 0.23 9.4 0.48 2.6 2718
position center 1.4 1608 (4.5) (0.32) (1.0) (1159) 308 314 356 322
for ø12
Pressure 7.4 0.25 1.7 1825 6.6 0.23 1.5
center (3.2) (0.34) (0.74) 1608
(835)
Note) ( ): denotes normal position.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.
4
Body Ported

Construction
Series SY 2 position single (A) (B)
4 2
JIS Symbol y wr u
2 position single qe

5 1 3
(EA) (P) (EB)
t
JIS Symbol
2 position double 2 position double (A) (B)
4 2
y w u qr

5 1 3
(EA) (P) (EB) t

3 position closed center / exhaust center / pressure center


JIS Symbol
(A) (B)
3 position closed center 4 2
y w u q r

3 position exhaust center

3 position pressure center 5 1 3


(EA) (P) (EB)
t
(This figure shows a closed center type.)

How to Change Port Block Assembly


Component Parts
If using body port type, both A and B port sizes can be changed by replacing
No. Description Material Note the port block assembly mounted on the body. When changing this block
Aluminum die-casted assembly, the correct screw torque must be achieved to avoid possible air
1 Body White
(SY3000: Zinc die-casted) leakage.
White For SY5000
M5 port block Assembly
2 Adapter plate Resin (SY9000: Gray) (Cassette type)
M5 port block Assembly
3 End plate Resin White (Threaded style) Fitting
4 Piston Resin – Assembly
5 Spool valve assembly Aluminum, HNBR –
Mounting screw

Replacement Parts
No. Description No.
6 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 5.
7 M5 port block assembly Refer to “How to Order Port Block Assembly” on page 6.
A

Bracket Assembly No.


B

Description No.
Bracket (For F1)
3
SX57000-16-2A (with mounting screw) Caution
3
Bracket (For F2) SX57000-16-1A (with mounting screw) Mounting screw tightening torques
∗ SY9000 has no bracket.
SY3000 (M2): 0.12 N·m ∗ Refer to “How to Order
SY 57 000 (M3): 0.6 N·m Port Block Assembly” on
SY9000 (M4): 1.4 N·m page 6 for part no.

5
SY3000/5000/7000/9000 Body Ported
How to Order Connector Assembly
How to Order Pilot Valve Assembly for L/M Plug Connector

For DC: SY100 30 4A


V111 5 G
Coil specifications
Light/surge voltage suppressor Without lead wire: SY100 30 A
Nil Without light/surge voltage suppressor (with connector and 2 of sockets only)
- Standard
With surge voltage suppressor
S Lead wire length
With power saving circuit
T Z With light/surge voltage suppressor
(24 VDC, 12 VDC only) - 300 mm
R With surge voltage suppressor (Non-polar type)
∗ Power saving circuit 6 600 mm
U With light/surge voltage suppressor (Non-polar type)
is not available in 10 1000 mm
the case of D, DO ∗ Power saving circuit is only available in the "Z" type.
15 1500 mm
or W type. Electrical entry 20 2000 mm
G Grommet, 300 mm lead wire 25 2500 mm
H Grommet, 600 mm lead wire 30 3000 mm
Rated voltage
L With lead wire 50 5000 mm
5 24 VDC L plug
LN connector Without lead wire
6 12 VDC
V 6 VDC
LO Without connector How to Order M8 Connector Cable
M With lead wire
S 5 VDC M plug
R 3 VDC
MN connector Without lead wire  Straight type
MO Without connector
WO M8 Without connector cable V100 49 1
W connector With connector cable Note 1)
Cable length
∗ For connector cable of M8 connector, refer to back page 12.
Note 1) Enter the cable length symbols in . Please be sure to 1 300 mm
fill in the blank referring to back page 13. 2 500 mm
3 1000 mm
 DIN terminal type 4 2000 mm

V115 5 D 7 5000 mm

Rated voltage Light/surge voltage suppressor


5 24 VDC - Without light/surge voltage suppressor
6 12 VDC S With surge voltage suppressor (Non-polar type)
1 100 VAC 50 60 Hz Z With light/surge voltage suppressor (Non-polar type)
2 200 VAC 50 60 Hz ∗ DOZ is not available.
110 VAC 50 60 Hz ∗ For AC voltage valves there is no “S” option.
3
[115 VAC 50 60 Hz] It is already built-in to the rectifier circuit.
220 VAC 50 60 Hz
4
[230 VAC 50 60 Hz] Electrical entry
D DIN With connector
∗ DC specifications of
DO terminal Without connector
type D and DO is
only available with 12 Note) Do not replace V111 (G, H, L, M)
How to Order Port Block Assembly and 24 VDC. to V115 (DIN terminal) and vice
versa when replacing pilot valve
assembly only.
SY 000 6A
Series
3 SY3000 Thread type ∗ Only replacement of the fittings assembly is possible.
5 SY5000 Nil Rc Metric size Inch size
7 SY7000 F G One-touch fitting for ø4 VVQ1000-50A-C4 One-touch fitting for ø 5 32" VVQ1000-50A-N3
SY3000 SY3000
9 SY9000 N NPT One-touch fitting for ø6 VVQ1000-50A-C6 One-touch fitting for ø 1 4" VVQ1000-50A-N7
T NPTF One-touch fitting for ø4 VVQ1000-51A-C4 One-touch fitting for ø 5 32" VVQ1000-51A-N3
A, B port size ∗ Except for M5 SY5000 One-touch fitting for ø6 VVQ1000-51A-C6 SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
Thread piping One-touch fitting for ø8 VVQ1000-51A-C8 One-touch fitting for ø 5 16" VVQ1000-51A-N9
Symbol Port size Applicable series One-touch fitting for ø8 VVQ2000-51A-C8 One-touch fitting for ø 5 16" VVQ2000-51A-N9
M5 M5 SY3000 SY7000 SY7000
One-touch fitting for ø10 VVQ2000-51A-C10 One-touch fitting for ø 3 8" VVQ2000-51A-N11
01 18 SY5000 One-touch fitting for ø8 VVQ4000-50B-C8 One-touch fitting for ø 5 16" VVQ4000-50B-N9
02 14 SY7000 SY9000
SY9000 One-touch fitting for ø10 VVQ4000-50B-C10 One-touch fitting for ø 3 8" VVQ4000-50B-N11
02 14
One-touch fitting for ø12 VVQ4000-50B-C12
SY9000
03 38

One-touch fitting (Metric size) One-touch fitting (Inch size) Mounting


Symbol Port size Applicable series Symbol Port size Applicable series screw
Port block assembly
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32" (Cassette type)
SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32" Fitting assembly
C6 One-touch fitting for ø6 SY5000 N7 One-touch fitting for ø 1 4" SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
SY7000 SY7000
C10 One-touch fitting for ø10 N11 One-touch fitting for ø 3 8"
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 16"
5
SY9000
C10 One-touch fitting for ø10 SY9000 N11 One-touch fitting for ø 3 8"
C12 One-touch fitting for ø12
6
Body Ported

Dimensions: Series SY3000


2 position single Foot bracket
G - C4, N3 (-F2)-Q SY3120- G C4, N3
Grommet (G), (H): SY3120- H C6, N7 H - C6, N7 -F1-Q
28.5

0.8
25

2
P

(15)
10
EA EB

2- ø1.5 die-cast hole 19 M5


For manifold gasket positioning (P, EA, EB port)
(35)

69.4 [71.6]
2- ø3.2 (27)

(3.2)
(Light/surge
(For mounting)
voltage suppressor)

C6: 33.6
N7: 37.4

1.2
(35.5)
(32)

- +
25

18.5
16.9

13.1
C6:33.6
(3.2) N7:37.4 7.5
28.5

22.5 38
31
G: Approx. 300
H: Approx. 600 66.9 13.1

11.6
(Lead wire length) 44.7
8.6

17
24
+ -
B

Manual override 10.2 2- ø3.2


(For mounting)
One-touch fitting 21.4 2- ø2.2
(A, B port) (For manifold mounting) G
Applicable tubing O.D.: ø4, ø5/32" SY3120-H -M5(-F2)-Q
ø6, ø1/4" M5
2-M3 depth 3.5 A, B port
9.5 (For mounting bracket)
4

28.5 [35.5]

23.5
25

18.5
16.9
22.5

L plug connector (L): M plug connector (M): M8 connector (WO):


1 1
SY3120-L- C4, N3 1
C6, N7 (-F 2 )-Q SY3120-M- C4, N3
C6, N7 (-F 2 ) -Q SY3120-WO- C4, N3
C6, N7 (-F 2 ) -Q
28.5
13.1
(Lead wire length)

33
Approx. 300

(Lead wire length)


Approx. 15.5 M8 x 1
39.6 300
75.9
76.8

68.5
62
67
22.5

22.5
22.5

16.9 16.9 16.9


18.5 18.5 18.5
C6: 33.6 C6: 33.6 C6: 33.6
N7: 37.4 (3.2) N7: 37.4 (3.2) N7: 37.4 (3.2)

Note) Refer to back page 12 for


dimensions of connector types.
7
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY3000


2 position double
C4, N3 G
Grommet (G), (H): SY3220- G
H - C6, N7 (-F2)-Q SY3220-H -M5(-F2)-Q
M5
(A, B port)
(35)
2- ø3.2
(27)

(3.2)
(For mounting) (Light/surge
voltage suppressor)

23.5
25

16.9
C6:33.6
N7:37.4
(35.5)
(32)

- +
25

16.9

13.1

28.5
28.5

G: Approx. 300
H: Approx. 600 88.8
(Lead wire length) 44.4
8.6

B
A

Manual override 10.2


One-touch fitting 21.4 2- ø2.2
A, B port (For manifold mounting)
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4" 2-M3 depth 3.5
9.5 (For mounting bracket)
4
10 0.8
2

P
(15)

EA EB

2- ø1.5 die-cast hole 19 M5


(For manifold gasket positioning) (P, EA, EB port)

L plug connector (L): M plug connector (M): M8 connector (WO):


1 1
SY3220-L- C4, N3 1
C6, N7 (-F 2 )-Q SY3220-M- C4, N3
C6, N7 (-F 2 ) -Q SY3220-WO- C4, N3
C6, N7 (-F 2 ) -Q
(Lead wire length)
Approx. 300

28.5
13.1
33
15.5 M8 x 1
39.6 Approx. 300
(Lead wire length)
108.6

106.8
79
89

92

16.9
C6:33.6 16.9
16.9 N7:37.4 (3.2) C6:33.6
C6:33.6 N7:37.4 (3.2)
N7:37.4 (3.2)
Note) Refer to back page 12 for
dimensions of connector types.
8
Body Ported

Dimensions: Series SY3000


3 position closed center / exhaust center / pressure center
3 3
Grommet (G), (H): SY3 45 20-G C4, N3
H- C6, N7 (-F2)-Q
SY3 4 20- G
H -M5(-F2)-Q
5
M5

10 0.8
(A, B port)

2
P

(15)
EA
2- ø1.5 die-cast hole 19 M5

23.5
25

16.9
For manifold gasket positioning (P, EA, EB port)
(35)
(27) 2- ø3.2

(3.2)
(Light/surge
(For mounting) voltage suppressor)

28.5
C6:33.6
N7:37.4

13.1
(35.5)
(32)

- +
25

16.9
28.5

G: Approx. 300
H: Approx. 600 97.3
(Lead wire length) 44.4
22.2 30.7
8.6

B
A

Manual override 10.2


One-touch fitting 21.4 2- ø2.2
(A, B port) (For manifold mounting)
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4" 2-M3 depth 3.5
9.5 (For mounting bracket)
4

L plug connector (L): M plug connector (M): M8 connector (WO):


3 3 3
SY3 45 20-L- C4, N3
C6, N7 (-F2)-Q SY3 45 20-M- C4, N3
C6, N7 (-F2)-Q SY3 45 20-WO- C4, N3
C6, N7 (-F2)-Q

28.5
13.1
(Lead wire length)

33
Approx. 300

15.5 M8 x 1
39.6 Approx. 300
(Lead wire length)
54.3

53.4
44.5

46
39.5
117.1

115.3
97.5

54.5
48

16.9
C6: 33.6 16.9
16.9 N7: 37.4 (3.2)
C6: 33.6
C6: 33.6 N7: 37.4 (3.2)
N7: 37.4 (3.2)
Note) Refer to back page 12 for
dimensions of connector types.
9
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY5000


2 position single Foot bracket
C4, N3 C4, N3
Grommet (G), (H): SY5120- G
H- C6, N7 (-F2)-Q SY5120- G
H -
C6, N7 -F1-Q
C8, N9 C8, N9
28.1

0.8
1.6

(20)
15
EA P EB

27.2 1/8
(P, EA, EB port)
2- ø2.2 die-cast hole
For manifold gasket positioning

88.6
(For
(45)
mounting)
(37) 2- ø3.2

(4.9)
(Light/surge
voltage suppressor)

1.2
(40.2)
(36.7)

12.7
(4.9)
40.4

40.4 10.5
28.1

- +
20.5

47
23

38
32.3 12.7
One-touch fitting
G: Approx. 300 A, B port

16.6
H: Approx. 600 85.9

29
22
+
Applicable tubing O.D.: ø4, ø5/32"
(Lead wire length)
63.7 ø8, ø5/16"
ø6, ø1/4" 2- ø3.2
11.6

(For mounting)
B
A

2- ø3.2
SY5120- G 1
H -01(-F 2 )-Q
Manual override 14.5
(For manifold mounting)
36
1/8
22.6 2-M3 depth 3.5 16.2 (A, B port)
(For mounting bracket)
16.7

32.5
28.1

20.5
23
32.3

L plug connector: L M plug connector: M DIN terminal (D): M8 connector (WO):


C4, N3 C4, N3 C4, N3 C4, N3
SY5120-L-C6, N7 (-F12 )-Q SY5120-M- C6, N7 (-F 12 )-Q SY5120-D- C6, N7 (-F 12 )-Q SY5120-WO- C6, N7 (-F 12 )-Q
C8, N9 C8, N9 C8, N9 C8, N9

60.9 Applicable cable O.D.


(Lead wire length)

ø3.5 to ø7
Approx. 300

53.4
28.1
Max. 10

42.1
12.7 27
32.6 M8 x 1
15.1
39.2 Approx. 300 Pg7
(Lead wire length)
105.8

94.9
95.8

104.9

87.5
86
81

65

32.3
32.3

32.3
32.3

20.5 20.5 20.5 20.5


23 23 23 23
40.4 (4.9) 40.4 (4.9) 40.4 (4.9) 40.4 (4.9)

Note) Refer to back page 12 for


dimensions of connector types.
10
Body Ported

Dimensions: Series SY5000


2 position double
C4, N3
Grommet (G), (H): SY5220- G SY5220-G
H-01(-F2)-Q
H -
C6, N7 (-F2)-Q
C8, N9 1/8
16.2

0.8
1.6
(A, B port)

(20)
15
EA P EB

32.5
28.1
27.2 1/8

20.5
2- ø2.2 die-cast hole (P, EA, EB port)
For manifold gasket positioning
(45)
2- ø3.2

(4.9)
(37)
(For mounting) (Light/surge
voltage suppressor)
(40.2)

40.4

12.7
(36.7)
28.1

- +
20.5

One-touch fitting
G: Approx. 300 (A, B port)
107.2 Applicable tubing O.D. : ø4, ø5/32"
H: Approx. 600
: ø6, ø1/4"
(Lead wire length) 62.8 : ø8, ø5/16"
11.6

B
A

Manual override 14.5 2- ø3.2


36 (For manifold mounting)

22.6 2-M3 depth 3.5


(For mounting bracket)
16.7

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
C4, N3 C4, N3 C4, N3 C4, N3
SY5220-L- C6, N7 (-F2)-Q SY5220-M- C6, N7 (-F2)-Q SY5220-D- C6, N7 (-F2)-Q SY5220-WO- C6, N7 (-F2)-Q
C8, N9 C8, N9 C8, N9 C8, N9

Applicable cable O.D.


(Lead wire length)

ø3.5 to ø7
Approx. 300

60.9
28.1 53.4
Max. 10

12.7 42.1
27 32.6 M8 x 1
39.2 Approx. 300 15.1
(Lead wire length) Pg7
110.4
125.2
107.4

145.2
97.4

65.4
127

147

20.5
20.5 40.4 (4.9) 20.5
20.5 40.4 (4.9)
40.4 (4.9)
40.4 (4.9)

Note) Refer to back page 12 for


dimensions of connector types.
11
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY5000


3 position closed center / exhaust center / pressure center
3 C4, N3 3 3
Grommet (G), (H): SY5 4 20- GH - C6, N7 (-F2)-Q SY5 4 20- 4 -01(-F2)-Q
5 C8, N9 5 5
1/8
16.2 (A, B port)

0.8
1.6

(20)
15

32.5
27.2 1/8

20.5
28.1
(P, EA, EB port)
2- ø2.2 die-cast hole
(45)
For manifold gasket positioning
(37)

(4.9)
2- ø3.2
(Light/surge
(For mounting)
voltage suppressor)
(40.2)

12.7
40.4
(36.7)
28.1

- +
20.5

One-touch fitting
(A, B port)
Applicable tubing O.D.:
ø4, ø5/32"
G: Approx. 300 ø6, ø1/4"
H: Approx. 600 119.8 ø8, ø5/16"
(Lead wire length) 53.6
31.4 44
11.6

Manual override 14.5 2- ø3.2


(For manifold mounting)
36

22.6 2-M3 depth 3.5


(For mounting bracket)
16.7

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 C4, N3 3 C4, N3 3 C4, N3 3 C4, N3
SY5 4 20-L- C6, N7 (-F2)-Q SY5 4 20-M- C6, N7 (-F2)-Q SY5 4 20-D- C6, N7 (-F2)-Q SY5 4 20-WO- C6, N7 (-F2)-Q
5 C8, N9 5 C8, N9 5 C8, N9 5 C8, N9

Applicable cable O.D.


(Lead wire length)

ø3.5 to ø7
Approx. 300

60.9
Max. 10

28.1 53.4
42.1
12.7 27 32.6 M8 x 1
39.2 Approx. 300 15.1
Pg7
(Lead wire length)
73.5

72.6
63.5

62.6
55.2
53.7
48.7

32.7
139.6

159.6

157.8
120

137.8
45.3
61.3

67.8

20.5
20.5 40.4 (4.9) 20.5
(4.9) 20.5 40.4 (4.9)
40.4
40.4 (4.9)

Note) Refer to back page 12 for


dimensions of connector types.
12
Body Ported

Dimensions: Series SY7000


2 position single
C8, N9 C8, N9
Grommet (G), (H): SY7120-G
H- C10, N11 (-F2)-Q SY7120-G
H- C10, N11-F1-Q
31.5

(66) (For mounting)


2- ø4.2 (Light/surge

(5.5)
(52)
voltage suppressor)
(49.5)

16.1
(42.5)

101.8
47.6
31.5

- +

24.5
28
39.4
One-touch fitting

1.2
G: Approx. 300
(A, B port)
H: Approx. 600 100.1
Applicable tubing O.D. : ø8, ø5/16"
(Lead wire length) 77.9 : ø10, ø3/8" (5.5) 47.6 12.5
13.6

57
B
46
A
16.1
Manual override 19 2- ø4.2
42 (For manifold mounting)
2-M4 depth 6.5

19.8

38
28
20

- +
(For mounting bracket)
7

2- ø4.2
(For mounting)

SY7120-G
H-02(-F2)-Q
1/4
(23.9)

1/4
18 0.9

20 A, B port
(P port)
2

EA P
31.5 [38.5]

EB

40
2- ø2.2 die-cast hole 36 1/8

24.5
28
For manifold gasket positioning (EA, EB port)
39.4

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY7120-L- C8, N9 1 C8, N9 1 C8, N9 1
C10, N11(-F 2 )-Q SY7120-M- C10, N11(-F 2)-Q SY7120-D- C10, N11(-F 2 )-Q SY7120-WO- C8, N9 1
C10, N11(-F 2 )-Q

Applicable cable O.D.


(Lead wire length)

66 ø3.5 to ø7
Approx. 300

58.5
Max. 10

31.5 47.2
16.1 32.1
36 M8 x1
42.6 Approx. 300 19
(Lead wire length) Pg7
119.1
120
110

100.2

109.1
95.2

101.7
79.2
39.4

39.4
39.4

39.4

24.5 24.5 24.5 24.5


28 28 28 28
47.6 (5.5) 47.6 (5.5) 47.6 (5.5) 47.6 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
13
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY7000


2 position double
Grommet (G), (H): SY7220-G C8, N9
H- C10, N11(-F2)-Q SY7220-G
H-02(-F2)-Q

1/4
1/4 20 (A, B port)

18 0.9
(P port)

(23.9)

31.5 [38.5]
EA P EB

40
24.5
2- ø2.2 die-cast hole 36 1/8
For manifold gasket positioning (EA, EB port)
(66) 2- ø4.2
(52) (Light/surge

(5.5)
voltage suppressor)
(49.5)

47.6

16.1
(42.5)
31.5

-+
24.5

One-touch fitting
(A, B port)
G: Approx. 300 Applicable tubing O.D.: ø8, ø5/16"
H: Approx. 600 121.4 ø10, ø3/8"
(Lead wire length) 77
13.6

Manual override 19 2- ø4.2


42 (For manifold mounting)
(For mounting)

2-M4 depth 6.5


20 (For mounting bracket)
7

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY7220-L-C8, N9 C8, N9 C8, N9 C8, N9
C10, N11(-F2)-Q SY7220-M- C10, N11(-F2)-Q SY7220-D- C10, N11(-F2)-Q SY7220-WO-C10, N11(-F2)-Q
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Approx. 300

66
Max. 10

58.5
31.5 47.2
16.1 32.1
36
18.5 M8 x 1
42.6 Approx. 300 Pg7
(Lead wire length)
161.2

159.4
121.6
111.6

79.6

124.6
139.4
141.2

24.5
24.5 47.6 (5.5) 24.5
47.6 (5.5) 24.5 47.6 (5.5)
47.6 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
14
Body Ported

Dimensions: Series SY7000


3 position closed center / exhaust center / pressure center
3 G C8, N9 3
Grommet (G), (H): SY7 4 20- H - C10, N11(-F2)-Q
5
SY7 4 20- G
H -02(-F2)-Q
5
1/4
1/4 20 (A, B port)

18 0.9
(P port)

(23.9)
2
EA P EB

40
31.5

24.5
2- ø2.2 die-cast hole 36 1/8
For manifold gasket positioning (EA, EB port)
2- ø4.2
(66) (For mounting)
(52) (Light/surge

(5.5)
voltage suppressor)
(49.5)
(42.5)

47.6
31.5

24.5

- +

16.1
One-touch fitting
(A, B port)
G: Approx. 300 Applicable tubing O.D. : ø8, ø5/16"
H: Approx. 600 134.4 : ø10, ø3/8"
(Lead wire length) 60.7
38.5 51.5
13.6

Manual override 19 2- ø4.2


42 (For manifold mounting)
2-M4 depth 6.5
20 (For mounting bracket)
7

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SY7 4 20-L- C8, N9
C10, N11(-F2)-Q SY7 4 20-M- C8, N9
C10, N11(-F2)-Q SY7 4 20-D- C8, N9
C10, N11(-F2)-Q SY7 4 20-WO- C8, N9
C10, N11(-F2)-Q
5 5 5 5

Applicable cable O.D.


(Lead wire length)

66 ø3.5 to ø7
Approx. 300

58.5
47.2
Max. 10

31.5 32.1
36
16.1
42.6 Approx. 300 18.5 M8 x 1
(Lead wire length) Pg7
80.6

79.7
70.6

60.8
55.8

69.7
62.3
39.8

152.4
174.2

172.4
134.6
154.2

52.8
68.8

75.3

24.5
24.5 47.6 (5.5) 24.5
47.6 (5.5) 24.5 47.6 (5.5)
47.6 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
15
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY9000


2 position single C8, N9
Grommet (G), (H): SYJ9120- G
H -C10, N11-Q SY9120- G 02
H - 03-Q
C12
1/4

0.5
[1(P), 5(EA), 3(EB) port]

23
3/8, 1/4
5EA 1P 3EB [4(A), 2(B) port)]
49.8

0.5
(Light/surge

(5.5)
voltage suppressor)
40.9 [47.9]

61
- +

39.1
36.6

25.5

33.6
10

2- ø4.4 24.9

56.3
(For mounting)
G: Approx. 300
H: Approx. 600 130.2 [132.4]
(Lead wire length) 108
Manual 6.5 56.3 36.6
override 39.1
4A 2B 51.5
18.4

One-touch fitting 33.6 3- ø3.2


[4(A), 2(B) port] (For manifold mounting)
64.2
Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"
ø12

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
C8, N9 C8, N9 C8, N9 C8, N9
SY9120-L- C10, N11-Q SY9120-M- C10, N11-Q SY9120-D- C10, N11-Q SY9120-WO-C10, N11-Q
C12 C12 C12 C12
(Lead wire length)

Applicable cable O.D.


ø3.5 to ø7
Approx. 300

74.7
40.9 67.2
Max. 10

25.5 55.9
40.9
45.4
M8 x 1
27.9
52 Approx. 300 Pg7
(Lead wire length)
149.2
150.1
140.1

125.3

139.2
109.3

131.8
130.3
56.3
56.3

56.3

56.3

36.6 36.6 36.6 36.6


39.1 39.1 39.1 39.1
61 (5.5) 61 (5.5) 61 (5.5) 61 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
16
Body Ported

Dimensions: Series SY9000


2 position double C8, N9
Grommet (G), (H): SYJ9220-G
H-C10, N11-Q SY9220- G 02
H -03-Q
C12
1/4

0.5
[1(P), 5(EA), 3(EB) port] 3/8, 1/4
[4(A), 2(B) port)]

23
5EA 1P 3EB

49.8

0.5
(5.5)
(Light/surge voltage
suppressor)

61
-+

33.6
40.9

36.6

25.5
10

2- ø4.4 24.9
G: Approx. 300 (For mounting)
H: Approx. 600 147.8
(Lead wire length) 103.4
Manual 6.5
override
4A 2B
18.4

36.6
51.5
One-touch fitting [4 (A), 2 (B) port] 33.6 3- ø3.2
Applicable tubing O.D.: ø8, ø5/16" (For manifold mounting)
64.2
: ø10, ø3/8"
: ø12

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
C8, N9 C8, N9 C8, N9 C8, N9
SY9220-L- C10, N11-Q SY9220-M- C10, N11-Q SY9220-D- C10, N11-Q SY9220-WO-C10, N11-Q
C12 C12 C12 C12
(Lead wire length)
Approx. 300

74.7 Applicable cable O.D.


40.9 67.2 ø3.5 to ø7
Max. 10

25.5 55.9
40.9
45.4
M8 x 1
27.9
52 Approx. 300 Pg7
(Lead wire length)
185.8
187.6

106
138

165.8
151
167.6

148

36.6
61 (5.5) 36.6
36.6 (5.5)
(5.5) 61
61
36.6
61 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
17
SY3000/5000/7000/9000 Body Ported

Dimensions: Series SY9000


3 position closed center / exhaust center / pressure 3
Grommet (G), (H): SY9 4 20- G
3 C8, N9 SY9 4 20- G 02
H - 03 -Q
H - C10, N11 -Q 5
5
C12
1/4 3/8, 1/4

0.5
[1(P), 5(EA), 3(EB) port]
[4(A), 2(B) port)

23
5EA 1P 3EB

49.8

0.5

(5.5)
61
- +

33.6
40.9

36.6

25.5
2- ø4.4 10
24.9 (Light/surge voltage
G: Approx. 300 (For mounting) suppressor)
H: Approx. 600 164.3
(Lead wire length) 73.9
51.7 68.2
Manual 6.5
override

4A 2B
18.4

36.6
One-touch fitting [4 (A), 2 (B) port] 33.6 3- ø3.2
Applicable tubing O.D. : ø8, ø5/16" (For manifold mounting) 51.5
64.2
: ø10, ø3/8"
: ø12

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 C8, N9 3 C8, N9 3 C8, N9 3 C8, N9
SY9 4 20-L-C10, N11-Q SY9 4 20-M-C10, N11-Q SY9 4 20-D- C10, N11-Q SY9 4 20-WO-C10, N11-Q
5 C12 5 C12 5 C12 5 C12
(Lead wire length)
Approx. 300

Applicable cable O.D.


74.7 ø3.5 to ø7
67.2
40.9
Max. 10

55.9
25.5 40.9
45.4
M8 x 1
27.9
52 Approx. 300 Pg7
(Lead wire length)
93.8

92.9

82.9
75.5
83.8

74
69

53
204.1

202.3

167.5

182.3
164.5
184.1

69.5
85.5

36.6
61 (5.5) 36.6
36.6
61 (5.5)
61 (5.5) 36.6
61 (5.5)

Note) Refer to back page 12 for


dimensions of connector types.
18
5 Port Solenoid Valve
Series SY3000/5000/7000/9000
Base Mounted
Single Unit Refer to www.smcworld.com for details of
products compatible with overseas standards.

How to Order

SY 5 2 40 5 L -Q
Series Port size Thread type
3 SY3000 Symbol Port size Applicable series - Rc
5 SY5000 - Without sub-plate F G
7 SY7000 18 N NPT
01 SY3000
9 SY9000 With sub-plate T NPTF
14 SY5000
02
With sub-plate SY7000
Type of actuation 03
38 SY7000
2 position single With sub-plate SY9000
12
1 04 SY9000
With sub-plate

Manual override
2 position double -: Non-locking D: Push-turn locking E: Push-turn locking
2 push type slotted type lever type

3 position closed center

3 position exhaust center

(Light/surge voltage suppressor)


3 position pressure center Electrical entry for G, H, L, M, W Electrical entry for D (Except SY3000)
5 - Without light/surge voltage suppressor - Without light/surge voltage suppressor
S With surge voltage suppressor S With surge voltage suppressor (Non-polar type)
Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
Pilot type U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S”
- Internal pilot ∗ Power saving circuit is only available in the option. It is already built-in to the
R External pilot "Z" type. rectifier circuit.

Coil specifications
- Standard
T With power saving circuit (24, 12 VDC only)
∗ Power saving circuit is not available in Electrical entry
the case of D, DO or W type. 24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC
Rated voltage Grommet L plug connector M plug connector DIN terminal M8 connector ∗
For DC G: Lead wire L: With lead wire M: With lead wire MN: Without lead (Except SY3000) WO: Without connector cable
length 300 mm (Length 300 mm) (Length 300 mm) wire D: With connector
5 24 VDC
+-
6 12 VDC +-
V 6 VDC
S 5 VDC –+
-+

R 3 VDC
For AC (50 60 Hz)
1 100 VAC H: Lead wire LN: Without LO: Without MO: Without DO: Without connector W: With connector cable
length 600 mm lead wire connector connector Note 1)
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of type D and DO is only –+
-+

available with 12 and 24 VDC.


∗ AC specification is only available with D, DO type.
∗ LN, MN type: with 2 sockets. ∗ DIN terminal type “Y” which conforms to EN-175301-803C
∗ For DIN terminal of SY3000 series, (former DIN43650C) is also available. For details, refer to
refer to back page 10. page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2
standard, is also available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to
19 fill in the blank referring to back page 13.
SY3000/5000/7000/9000 Base Mounted

Specifications

Series SY3000 SY5000 SY7000 SY9000


Fluid Air
Internal pilot 2 position single 0.15 to 0.7
Operating pressure 2 position double 0.1 to 0.7
range(MPa) 3 position 0.2 to 0.7
Operating pressure range –100 kPa to 0.7
External pilot
Pilot 2 position single 0.25 to 0.7
Operating pressure
pressure 2 position double 0.25 to 0.7
range(MPa)
range 3 position 0.25 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing. Refer to back page 3.)
Max. operating 2 Position single, Double 10 5 5 5
frequency (Hz) 3 position 3 3 3 3
Manual override Non-locking push type,
(Manual operation) Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust Internal pilot Common exhaust type for main and pilot valve
method External pilot Pilot valve individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 150/30
Enclosure Dust proof (∗ DIN terminal and M8 connector: IP65)
Made to Order ∗ Based on IEC60529)
(For details, refer to pages 199 through to 213.) Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles
to the main valve and armature in both energised and de-energised states every
once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energised and de-energised states in the axial direction and at the
right angles to the main valve and armature. (Values at the initial period)

Response Time Solenoid Specifications


Note) Based on dynamic performance
test, JIS B 8375-1981. (Coil Grommet (G), (H) DIN terminal (D)
temperature: 20°C, at rated voltage) L plug connector (L) M8 connector (W)
Electrical entry M plug connector (M)
SY3000
G, H, L, M, W D
Response time (ms) Coil rated DC 24, 12, 6, 5, 3 24, 12
Type of (at the pressure of 0.5 MPa) voltage (V) AC 50 60 Hz 100, 110 200, 220
actuation Without light/surge With light/surge voltage suppressor Allowable voltage fluctuation (%) ±10% of rated voltage ∗
voltage suppressor Type S, Z Type R, U Power Standard 0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
2 position single 12 or less 15 or less 12 or less consumption (W) DC With power saving circuit 0.1 (With indicator light only)
2 position double 10 or less 13 or less 10 or less 100 V - 0.78 (With indicator light: 0.87)
3 position 15 or less 20 or less 16 or less 110 V - 0.86 (With indicator light: 0.97)
Apparent power [115 V] - [0.94 (With indicator light: 1.07)]
SY5000 (VA) ∗ AC
200 V - 1.15 (With indicator light: 1.30)
Response time (ms) 220 V - 1.27 (With indicator light: 1.46)
(at the pressure of 0.5 MPa) [230 V] - [1.39 (With indicator light: 1.60)]
Type of
Surge voltage suppressor Diode (Varistor is for DIN terminal and Non-polar type.)
actuation Without light/surge With light/surge voltage suppressor
Indicator light LED (AC of DIN connector is neon light.)
voltage suppressor Type S, Z Type R, U
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
2 position single 19 or less 26 or less 19 or less
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
2 position double 18 or less 22 or less 18 or less
∗ S, Z and T type (with power saving circuit) should be used within the following allowable voltage
3 position 32 or less 38 or less 32 or less
fluctuation range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
SY7000 12 VDC: –4% to +10%
Response time (ms) T type: 24 VDC: –8% to +10%
Type of (at the pressure of 0.5 MPa) 12 VDC: –6% to +10%
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 31 or less 38 or less 33 or less
2 position double 27 or less 30 or less 28 or less
3 position 50 or less 56 or less 50 or less

SY9000
Response time (ms)
Type of (at the pressure of 0.5 MPa)
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 35 or less 41 or less 35 or less
2 position double 35 or less 41 or less 35 or less
3 position 62 or less 64 or less 62 or less

20
Base Mounted

Flow Characteristics/Weight
Series SY3000
Flow characteristics Note 1) Weight (g) Note 2)
Type of Port
Valve model 1  4/2 (P  A/B)
Grommet L plug connector, W
4/2  5/3 (A/B  EA/EB)
actuation size
C (dm3/(s·bar)) b Cv Q[l/min(ANR)] C (dm3/(s·bar)) b Cv Q[l/min(ANR)] M plug connector M8 connector
2 Single 84 [50] 85 [53] 89 [57]
position Double 1.0 0.30 0.24 254 1.1 0.30 0.26 280
102 [68] 107 [73] 115 [81]
Closed center 0.77 0.28 0.18 193 0.85 0.30 0.19 216
SY340--01 Exhaust 18 1.1 0.26 0.24 273
3 0.73 0.31 0.18 187
center (0.55) (0.52) (0.16) (164) 104 [69] 109 [74] 117 [82]
position
Pressure 1.2 0.24 0.29 294
0.89 0.47 0.24 255
center (0.51) (0.45) (0.14) (144)
Note 1) [ ]: denotes the normal position. Note 2) [ ]: denotes without sub-plate.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard conditions at an upstream pressure of 0.6 MPa
(relative pressure) and a differential pressure of 0.1MPa.

Series SY5000
Flow characteristics Note 1) Weight (g) Note 2)
Type of Port
Valve model 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) L plug connector, W
actuation size Grommet DIN terminal
C (dm3/(s·bar)) b Cv Q[l/min(ANR)] C (dm3/(s·bar)) b Cv Q[l/min(ANR)] M plug connector M8 connector
2 Single 121 [58] 123 [61] 154 [92] 127 [65]
position Double 2.4 0.41 0.64 658 2.8 0.29 0.66 707
139 [76] 144 [81] 186 [123] 152 [89]
Closed center 1.8 0.47 0.50 516 1.8 0.40 0.47 490
SY540--02 Exhaust 14 3.0 0.33 0.72 778
3 1.4 0.55 0.44 430
center (1.2) (0.48) (0.37) (347) 144 [82] 150 [87] 192 [129] 158 [95]
position
Pressure 3.3 0.36 0.85 873
1.8 0.40 0.48 490
center (0.84) (0.60) (0.28) (270)
Note 1) [ ]: denotes the normal position. Note 2) [ ]: denotes without sub-plate.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard conditions at an upstream pressure of 0.6 MPa
(relative pressure) and a differential pressure of 0.1MPa.

Series SY7000
Flow characteristics Note 1) Weight (g) Note 2)
Type of Port
Valve model 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) L plug connector, W
actuation size Grommet DIN terminal
C (dm3/(s·bar)) b Cv Q[l/min(ANR)] C (dm3/(s·bar)) b Cv Q[l/min(ANR)] M plug connector M8 connector
2 Single 218 [89] 221 [92] 242 [113] 225 [96]
4.1 0.41 1.1 1123 4.1 0.29 1.0 1036
position Double 237 [108] 242 [113] 284 [155] 250 [121]
Closed center 3.0 0.43 0.80 834 2.6 0.41 0.72 712
SY740--02 Exhaust 14 4.7 0.35 1.1
2.6 0.42 0.71 718 1235
3 center (1.7) (0.48) (0.49) 239 [110] 245 [116] 287 [158] 253 [124]
position (492)
Pressure 5.3 0.39 1.3 1431
2.2 0.49 0.63 641
center (2.3) (0.49) (0.65) (670)
2 Single 218 [89] 221 [92] 242 [113] 225 [96]
4.9 0.29 1.2 1238 4.5 0.27 1.1 1123
position Double 237 [108] 242 [113] 284 [155] 250 [121]
Closed center 3.0 0.40 0.80 816 2.6 0.45 0.73 734
SY740--03 Exhaust 38 4.8 0.35 1.1
2.6 0.42 0.71 718 1261
3 center (1.7) (0.48) (0.49) 239 [110] 245 [116] 287 [158] 253 [124]
position (492)
Pressure 5.3 0.31 1.3 1356
2.3 0.45 0.66 649
center (2.3) (0.51) (0.64) (682)
Note 1) [ ]: denotes the normal position. Note 2) [ ]: denotes without sub-plate.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard conditions at an upstream pressure of 0.6 MPa
(relative pressure) and a differential pressure of 0.1MPa.

Series SY9000
Flow characteristics Note1) Weight (g) Note 2)
Type of Port
Valve model 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) L plug connector, W
actuation size Grommet DIN terminal
C (dm3/(s·bar)) b Cv Q[l/min(ANR)] C (dm3/(s·bar)) b Cv Q[l/min(ANR)] M plug connector M8 connector
2 Single 469[172] 472[175] 493[196] 476[179]
7.9 0.34 2.0 2062 9.6 0.43 2.6 2670
position Double 488[191] 494[197] 535[239] 502[205]
Closed center 7.5 0.33 1.8 1944 7.3 0.30 1.7 1856
SY940--03 Exhaust 38 13 0.23 2.8 3168
3 7.2 0.34 1.7 1879
center (4.0) (0.41) (0.95) (1096) 512[215] 518[221] 560[263] 526[229]
position
Pressure 12 0.26 2.8 2977
6.7 0.40 1.9 1823
center (3.3) (0.41) (0.84) (904)
2 Single 448 [172] 453 [175] 472 457[179]
8.0 0.48 2.2 2313 10 0.29 2.5 2527
position Double 467 [191] 473 [197] 515 481[205]
Closed center 7.6 0.32 1.8 1957 7.3 0.32 1.8 1880
SY940--04 Exhaust 12 13 0.32 3.6 3348
3 7.3 0.42 2.0 2015
center (4.7) (0.54) (1.5) (1430) 491 [215] 497 [221] 539 505[229]
position
Pressure 12 0.33 3.3 3111
7.4 0.33 1.9 1918
center (3.3) (0.51) (0.94) (978)
Note 1) [ ]: denotes the normal position. Note 2) [ ]: denotes without sub-plate.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard conditions at an upstream pressure of 0.6 MPa
(relative pressure) and a differential pressure of 0.1MPa.

21
SY3000/5000/7000/9000 Base Mounted

Construction
Series SY
JIS Symbol
2 position single 2 position single
w r t q e

y
i
4 2
(A) (B)
5 1 3
(EA) (P) (EB)

JIS Symbol
2 position double 2 position double
w r t q

y
i
4 2
(A) (B)
5 1 3
(EA) (P) (EB)

JIS Symbol
3 position closed center 3 position closed center / exhaust center / pressure center
w r t q
u
3 position exhaust center

i y
3 position pressure center 4 2
(A) (B)
5 1 3
(EA) (P) (EB)

(This figure shows a closed center type.)


Component Parts
No. Description Material Note
Aluminum die-casted
1 Body White
(SY3000: Zinc die-casted)
White
2 Adapter plate Resin
(SY9000: Gray)
3 End plate Resin White
4 Piston Resin –
5 Spool valve assembly Aluminum, HNBR –
Caution
Replacement Parts
Part No.
Mounting screw
No. Description
SY340 SY540 SY740 SY940
Note tightening torques
1 4: SY7000-27-1 ∗ -Q 3 8 : SY9000-27-1 ∗ -Q Aluminum M2: 0.16 N·m
6 Sub-plate SY3000-27-1 ∗ -Q SY5000-27-1 ∗ -Q 3
8 : SY7000-27-2 ∗ -Q 1 2 : SY9000-27-2 ∗ -Q die-casted M3: 0.8 N·m
7 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 23. M4: 1.4 N·m
8 Gasket SY3000-11-25 SY5000-11-15 SY7000-11-11 SY9000-11-2 H-NBR
Round head SY3000-23-4 SY9000-18-2 For valve mounting
– M3 x 26 M4 x 31
combination screw (M2 x 21) (M3 x 42) (Matt nickel plated)
∗ Thread type

22
Base Mounted

How to Order Connector Assembly


How to Order Pilot Valve Assembly for L/M Plug Connector

V111 5 G For DC: SY100 30 4A


Coil specifications Light/surge voltage suppressor
- Without light/surge voltage suppressor Without lead wire: SY100 30 A
- Standard
With power saving circuit S With surge voltage suppressor Only connector and sockets (x 2 pcs.)
T (24 VDC, 12 VDC only) Z With light/surge voltage suppressor Lead wire length
∗ Power saving circuit R With surge voltage suppressor (Non-polar type) - 300 mm
is not available in U With light/surge voltage suppressor (Non-polar type) 6 600 mm
the case of D, DO ∗ Power saving circuit is only available in the "Z" type. 10 1000 mm
or W type. 15 1500 mm
20 2000 mm
Rated voltage 25 2500 mm
5 24 VDC 30 3000 mm
6 12 VDC Electrical entry
50 5000 mm
V 6 VDC G Grommet, 300 mm lead wire
S 5 VDC H Grommet, 600 mm lead wire
R 3 VDC L With lead wire
L plug
LN connector Without lead wire
LO Without connector
M With lead wire
M plug
MN connector Without lead wire
MO Without connector
WO M8 Without connector cable
W connector With connector cable Note 1)
∗ For connector cable of M8 connector,
refer to back page 12.
Note 1) Enter the cable length symbols in How to Order M8 Connector Cable
. Please be sure to fill in the blank
referring to back page 13.
 Straight type
 DIN terminal type
V100 49 1
V115 5 D
Cable length
Rated voltage Light/surge voltage suppressor 1 300 mm
5 24 VDC - Without light/surge voltage suppressor 2 500 mm
6 12 VDC S With surge voltage suppressor (Non-polar type) 3 1000 mm
1 100 VAC 50 60 Hz Z With light/surge voltage suppressor (Non-polar type) 4 2000 mm
2 200 VAC 50 60 Hz 7 5000 mm
∗ DOZ is not available.
110 VAC 50 60 Hz ∗ For AC voltage valves there is no “S” option. It
3 is already built-in to the rectifier circuit.
[115 VAC 50 60 Hz]
220 VAC 50 60 Hz
4
[230 VAC 50 60 Hz] Electrical entry
D DIN With connector
∗ DC specifications of
type D and DO is DO terminal Without connector
only available with Note) Do not replace V111 (G, H,
12 and 24 VDC. L, M) to V115 (DIN terminal)
and vice versa when
replacing pilot valve
assembly only.

23
SY3000/5000/7000/9000 Base Mounted

How to Order Interface Regulator


Series SY3000 Series SY5000
ARBY3000 05 P 2 ARBY5000 00 P 2
Pressure gauge connection port Regulating port Pressure gauge connection port Regulating port
05 Pressure gauge (G15-10-01) P P port 00 Pressure gauge (G15-10-01) P P port
M1 Plug (M-5P) A1 A port (P controlled type, A port regulation) M1 Plug (M-5P) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)

ARBY3000-05--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2

– –
+ +

– –
+ +

Series SY7000
ARBY7000 00 P 2
Pressure gauge connection port Regulating port
00 Pressure gauge (G15-10-01) P P port
M1 Plug (M-5P) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation)

ARBY7000-00--2 ARBY7000-M1--2

– –
+ +

Accessory
Series Round head combination screw Gasket
SY3000-23-10 Caution
ARBY3000 SX3000-57-4
(M2 x 36) Mounting screw
M3 x 48.5, tightening torques
ARBY5000 SX5000-57-6
Matt nickel plated
M2: 0.16 N·m
ARBY7000
M4 x 57,
SX7000-57-4
M3: 0.8 N·m
Matt nickel plated M4: 1.4 N·m
24
Base Mounted

Dimensions: Series SY3000


2 position single
Grommet (G), (H): SY3140(R)- G
H -01-Q

53.5

43.5
50
24.5
16.5
11 11

7.5
1/8 20.5
(P, EA, EB port) 41
38.1
19 19
2- ø3.2
17 35 5 17
(For mounting)

3
Manual override A B

22

- +
B
A

X
PE

EA P EB

M5 2 M5
(Pilot EXH port) (External pilot port)
G: Approx. 300 44.7
<In the case of external pilot type> H: Approx. 600 66.9 (Light/surge voltage suppressor)
(Lead wire length)

14.5 1/8
With interface regulator (A, B port)

13.5
140.7
ø15
68.5
68

65
58.5
32.5
24.5

With plug (12.5) 41 (36.8)

L plug connector (L): M plug connector (M): M8 connector (WO):


SY3140(R)-L-01-Q SY3140(R)-M-01-Q SY3140(R)-WO-01-Q
(Lead wire length)
Approx. 300

53.5
38.1
58
(Lead wire length) M8 x 1
40.5
64.6 Approx. 300
75.9
76.8

68.5
62
67

11 11
11 11
11 11

20.5
20.5
20.5

7.5 7.5 7.5


2

2
2

16.5 16.5 16.5


24.5 24.5 24.5
50

Note) Refer to back page 12 for


dimensions of connector types.
25
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY3000


2 position double
Grommet (G), (H): SY3240(R)-G
H -01-Q

53.5
50
24.5
16.5
11 11

7.5
1/8 20.5
(P, EA, EB port) 41
38.1
19 (For mounting) 19
17 35 2- ø3.2 17
Manual override

3
A B

22

- +
- +

X
PE

EA P EB
M5 G: Approx. 300 44.4 M5
(Pilot EXH port) H: Approx. 600 88.8 (External pilot port)
<In the case of external pilot type> (Lead wire length)
14.5 1/8
(Light/surge voltage suppressor)
(A, B port)

13.5
With interface regulator
154.2
ø15
68.5
68

65
32.5
24.5

With plug (12.5) 41 (36.8)

L plug connector (L): M plug connector (M): M8 connector (WO):


SY3240(R)-L-01-Q SY3240(R)-M-01-Q SY3240(R)-WO-01-Q
(Lead wire length)
Approx. 300

53.5
38.1
58 M8 x 1
(Lead wire length)
40.5
Approx. 300
64.6
11 11

11 11

106.8
11 11

108.6

79

92
89
20.5

20.5
20.5

7.5 7.5 7.5


16.5 16.5 16.5
24.5 24.5 24.5

50

Note) Refer to back page 12 for


dimensions of connector types.

26
Base Mounted

Dimensions: Series SY3000


3 position closed center / exhaust center / pressure center
3 G
Grommet (G), (H): SY3 45 40(R)- H -01-Q

53.5
50
24.5
16.5
11 11

7.5
1/8 20.5 (Light/surge voltage suppressor)
P, EA, EB port 41
38.1
19 2-ø3.2 19
17 35 3 (For mounting) 17
Manual override

3
A B

22

- +
- +

B
A
PE

X
EA P EB

M5 42.7 10.2 M5
(Pilot EXH port) G: Approx. 300 32.4 (External pilot port)
<In the case of external pilot type> H: Approx. 600 97.3
(Lead wire length)
14.5 1/8
(A, B port)
With interface regulator

13.5
140.7
ø15
68.5
68

65
32.5
24.5

With plug (12.5) 41 (36.8)

L plug connector (L): M plug connector (M): M8 connector (WO):


3 3 3
SY3 45 40(R)-L-01-Q SY3 45 40(R)-M-01-Q SY3 45 40(R)-WO-01-Q
(Lead wire length)
Approx. 300

53.5
38.1
58 M8 x 1
(Lead wire length) 40.5
Approx. 300
64.6
66.5
60
11 11

11 11
11 11

115.3
97.5
117.1

20.5

20.5
20.5

32.5 [34.7]

7.5 7.5 7.5


27.5
42.3 [44.5]

16.5 16.5
34
41.4

16.5
24.5 24.5 24.5

50

Note) Refer to back page 12 for


dimensions of connector types.

27
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY5000


2 position single
Grommet (G), (H): SY5140(R)- G
H -02-Q

50.6

45.5
22
9.5
18 18
28 1/4
(Light/surge
P, EA, EB port voltage suppressor)
56
35.2
17 2-ø4.3 17
M5 15.5 (For mounting) 48 8.3 15.5
(External pilot port) Manual override
A B

4
35

- +
B
A
X

PE
EA P EB

4.3 M5
G: Approx. 300 63.7 (Pilot EXH port)
<In the case of external
H: Approx. 600 85.9
pilot type>
(Lead wire length)
1/4
With interface regulator (A, B port)
157 18

9.5
73.6

68.5
ø15

34
22

With plug (16.5) 56 (59)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY5140(R)-L-02-Q SY5140(R)-M-02-Q SY5140(R)-D-02-Q SY5140(R)-WO-02-Q
(Lead wire length)

Applicable cable O.D.


83.4
Approx. 300

ø3.5 to ø7
75.9
Max. 10

50.6
64.6
35.2 49.5 M8 x 1
55.1
(Lead wire length) 37.6
61.7 Approx. 300
Pg7
105.8

104.9
95.8

94.9
87.5
81
86

18

18
18
18

65
18

18

18
18
28

28

28

28

9.5 9.5 9.5 9.5


4.3

4.3

4.3
4.3

22 22 22 22

Note) Refer to back page 12 for


dimensions of connector types.

28
Base Mounted

Dimensions: Series SY5000


2 position double
Grommet (G), (H): SY5240(R)- G
H -02-Q

50.6
22
9.5
18 18
28
1/4
56 (P, EA, EB port)
(Light/surge voltage suppressor)
35.2
17 2- ø4.3 17
M5 15.5 (For mounting) 48 15.5
(External pilot port) Manual override

4
A B
- +

35

- +
B
A
X

PE
EA P EB

G: Approx. 300 62.8 M5


H: Approx. 600 107.2 (Pilot EXH port)
(Lead wire length) <In the case of external
1/4 pilot type>
(A, B port)
18

9.5
With interface regulator
157
73.6
ø15

34
22

With plug 56 (59)


(16.5)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY5240(R)-L-02-Q SY5240(R)-M-02-Q SY5240(R)-D-02-Q SY5240(R)-WO-02-Q
Applicable cable O.D.
(Lead wire length)

83.4 ø3.5 to ø7
Approx. 300

75.9
Max. 10

50.6
64.6
35.2 49.5
55.1 M8 x 1
(Lead wire length) 37.6
61.7 Approx. 300
Pg7
18 18

18
18
18

107.4

145.2

110.4
125.2
97.4

65.4
127

147

18
18

18

28

28
28

28

9.5 9.5
22 22
9.5 9.5
22 22

Note) Refer to back page 12 for


dimensions of connector types.
29
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY5000


3 position closed center / exhaust center / pressure center
3
Grommet (G), (H): SY5 4 40(R)- GH -02-Q 5

50.6
22
18 18

9.5
28 1/4
56 (P, EA, EB port)
(Light/surge voltage suppressor)
35.2
17 2-ø4.3 17
M5 15.5 (For mounting) 48 4 15.5
(External pilot port)

4
Manual override A B

35

- +
- +

B
A
X

PE
EA P EB

59.4 16 M5
G: Approx. 300 38.2 (Pilot EXH port)
H: Approx. 600 119.8 <In the case of
external pilot type>
(Lead wire length)
1/4
With interface regulator (A, B port)
18
157

9.5
73.6
ø15

34
22

With plug 56 (59)


(16.5)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SY5 45 40(R)-L-02-Q SY5 4 40(R)-M-02-Q SY5 4 40(R)-D-02-Q SY5 4 40(R)-WO-02-Q
5 5 5
(Lead wire length)

Applicable cable O.D.


Approx. 300

83.4 ø3.5 to ø7
75.9
Max. 10

50.6
64.6
35.2 49.5
55.1 M8 x 1
(Lead wire length)
Approx. 300
37.6
61.7
Pg7
83.2
76.7

18 18

18
18

18

60.7
159.6

157.8

137.8
139.6

120

18
18

18
28

28

28
28

17.3

9.5 9.5
33.3

22 22
39.8
38.3

9.5 9.5
47.2
48.1

57.2
58.1

22 22

Note) Refer to back page 12 for


dimensions of connector types.

30
Base Mounted

Dimensions: Series SY7000


2 position single
Grommet (G), (H): SY7140(R)- G
H - 03 -Q
02

58.5

55
26.5
13.5
11.5
20.5 20.5
33 3/8,1/4
69 (P, EA, EB port)
(Light/surge voltage suppressor)
61 10.4 43.1
21 Manual override 2-ø4.3 21.5
(For mounting)
A B

PE
38
46

- +
B
A
X

EA P EB

21.5 6.4 21
M5 G: Approx. 300 77.9 M5
(External pilot port) H: Approx. 600 100.1 (Pilot EXH port)
(Lead wire length) <In the case of external
3/8,1/4
21 pilot type>
(A, B port)
With interface regulator

13.5
184.5
86.7

83.2
ø15

41.2
26.5

With plug (17) 69 (73)

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY7140(R)-L- 02 02
03 -Q SY7140(R)-M- 03 -Q SY7140(R)-D- 02
03 -Q SY7140(R)-WO- 02
03 -Q
(Lead wire length)

93 Applicable cable O.D.


Approx. 300

85.5 ø3.5 to ø7
Max. 10

58.5 74.2
43.1 59.1
63
(Lead wire length) M8 x 1
45.5
69.6 Approx. 300
Pg7
119.1
120

109.1
110

101.7
100.2
20.5 20.5

20.5 20.5

20.5 20.5
20.5 20.5

95.2

79.2
33

33
33
33

11.5 11.5 11.5


6.4

11.5
6.4
6.4

6.4

13.5 13.5 13.5 13.5


26.5 26.5 26.5 26.5

Note) Refer to back page 12 for


dimensions of connector types.

31
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY7000


2 position double
Grommet (G), (H): SY7240(R)- G
H - 03-Q
02

58.5
26.5
13.5
20.5 20.5

11.5
33 3/8,1/4
(Light/surge voltage suppressor)
69 (P, EA, EB port)
2-ø4.3 43.1
21 61
(For mounting)
Manual override 21.5
A B

PE
38
46
-+

B
A

-+
X

EA P EB

21.5 G: Approx. 300 77


H: Approx. 600 121.4 21
M5
(External pilot port) (Lead wire length) M5
3/8,1/4 (Pilot EXH port)
21 (A, B port) <In the case of external
pilot type>

13.5
With interface regulator
184.5
86.7
ø15

41.2
26.5

With plug (17) 69 (73)

L plug connector: L M plug connector: M DIN terminal (D): M8 connector (WO):


SY7240(R)-L- 02
03-Q SY7240(R)-M- 0203-Q SY7240(R)-D- 02
03-Q SY7240(R)-WO- 02
03 -Q
(Lead wire length)

93 Applicable cable O.D.


Approx. 300

85.5 ø3.5 to ø7
Max. 10

58.5 74.2
43.1 59.1
63 M8 x 1
(Lead wire length)
Approx. 300
45.5
69.6
Pg7
20.5 20.5

20.5 20.5
20.5 20.5
20.5 20.5

161.2

159.4

124.6
139.4
141.2

111.6

79.6
121.6

33

33
33

33

11.5 11.5 11.5 11.5


13.5 13.5 13.5 13.5
26.5 26.5 26.5 26.5

Note) Refer to back page 12 for


dimensions of connector types.

32
Base Mounted

Dimensions: Series SY7000


3 position closed center / exhaust center / pressure center
3
Grommet (G), (H): SY7 45 40(R)- G
H -03-Q
02

58.5
26.5
20.5 20.5

11.5
13.5
(Light/surge voltage suppressor)
3/8,1/4 33
(P, EA, EB port) 69
43.1
2-ø4.3
21 61 4 21.5
(For mounting)
Manual override
A B

PE
38
46
- +

-+
B
A
X

EA P EB

21.5 71.5 18.5 21


M5 G: Approx. 300 40.7 M5
(External pilot port) H: Approx. 600 134.4 (Pilot EXH port)
(Lead wire length) <In the case of external
3/8,1/4
21 pilot type>
(A, B port)
With interface regulator

13.5
184.5
86.7
ø15

41.2
26.5

With plug (17) 69 (73)

L plug connector: L M plug connector: M DIN terminal (D): M8 connector (WO):


3 3 3 3
SY7 45 40(R)-L- 02
03-Q SY7 45 40(R)-M- 02
03 -Q SY7 45 40(R)-D- 02
03 -Q SY7 45 40(R)-WO- 02
03 -Q
(Lead wire length)

Applicable cable O.D.


93
Approx. 300

85.5 ø3.5 to ø7
Max. 10

58.5 74.2
43.1 59.1
63
(Lead wire length) M8 x 1
Approx. 300 45.5
69.6
Pg7
95.3
88.8
20.5 20.5

20.5 20.5

20.5 20.5
20.5 20.5

154.2

72.8
134.6

174.2

172.4

152.4
33

33

33
33

11.5 11.5 11.5 11.5


19.8
35.8

13.5 13.5 13.5 13.5


40.8

42.3
49.7
50.6

26.5 26.5 26.5 26.5


59.7
60.6

Note) Refer to back page 12 for


dimensions of connector types.

33
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY9000


2 position single
Grommet (G), (H): SYJ9140- G 03
H - 04 -Q

75.4

73.6
34.5
17.5
15.5
29.5 29.5
44.5 3/8,1/2
96.5
[1(P), 5(EA), 3(EB) port]

(Light/surge voltage suppressor)


60
27 86.5 16.8 2-ø5.4 25
(For mounting)
Manual override
4A 2B

PE
47
57

-+
A

B
X

5EA 1P 3EB

25 11.8 27 1/8
1/8 G: Approx. 300 108 (Pilot EXH port)
(External pilot port) H: Approx. 600 130.2 <In the case of external pilot type>
(Lead wire length)

3/8, 1/2 29 30
[4(A), 2(B) port]
17.5

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY9140(R)-L- 03 03
04 -Q SY9140(R)-M- 04 -Q SY9140(R)-D- 03
04 -Q SY9140(R)-WO- 03
04 -Q
(Lead wire length)
Approx. 300

Applicable cable O.D.


109.2 ø3.5 to ø7
75.4 101.7
Max. 10

60 90.4
75.4
(Lead wire length) 79.9 M8 x 1
86.5 Approx. 300 62.4
Pg7
150.1

149.2
140.1

139.2
29.5

29.5

29.5

29.5

131.8
130.3
125.3

109.3
29.5

29.5

29.5
29.5

44.5

44.5
11.8 44.5
44.5
11.8

11.8

15.5 15.5 15.5


11.8

15.5
17.5 17.5 17.5 17.5
34.5 34.5 34.5 34.5

Note) Refer to back page 12 for


dimensions of connector types.

34
Base Mounted

Dimensions: Series SY9000


2 position double
G
Grommet (G), (H): SY9240(R)- H - 03
04-Q

75.4

34.5
17.5
15.5
29.5 29.5
44.5 3/8, 1/2
96.5
[1(P), 5(EA), 3(EB) port]
(Light/surge voltage suppressor)
2-ø5.4 60
27 86.5 (For mounting) 25

Manual override
4A 2B

PE
47
57
-+

-+
B
A
X

5EA 1P 3EB

25 96.5 7.2 27 1/8


1/8 G: Approx. 300 29.4 (Pilot EXH port)
(External pilot port) H: Approx. 600 147.8 <In the case of external pilot type>
(Lead wire length)

3/8, 1/2
29 30
[4(A), 2(B) port]
17.5

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
SY9240(R)-L- 03 03
04-Q SY9240(R)-M- 04-Q SY9240(R)-D- 03
04-Q SY9240(R)-WO- 03
04-Q
Applicable cable O.D.
(Lead wire length)
Approx. 300

109.2 ø3.5 to ø7
75.4 101.7
Max. 10

60 90.4
75.4
(Lead wire length) 79.9 M8 x 1
Approx. 300 62.4
86.5
Pg7
113.5

29.5 29.5

29.5
29.5

29.5

120
187.6

185.8

165.8
167.6

106
148
29.5
29.5

29.5
44.5
44.5

44.5

44.5

15.5 15.5 15.5 15.5


24.5
29.5

38.4
31

17.5 17.5 17.5 17.5


39.3

34.5 34.5 34.5 34.5

Note) Refer to back page 12 for


dimensions of connector types.

35
SY3000/5000/7000/9000 Base Mounted

Dimensions: Series SY9000


3 position closed center / exhaust center / pressure center
3 G
Grommet (G), (H): SY9 4 40- H - 03
04 -Q 5

75.4

34.5
17.5
15.5
29.5 29.5
44.5 3/8, 1/2
96.5 [1(P), 5(EA), 3(EB) port]
(Light/surge voltage suppressor)
2-ø5.4 60
27 86.5 5 (For mounting) 25

Manual override 4 A 2 B

PE
47
57

-+
-+

B
X

5 EA 1 P 3 EB

25 96.2 23.7 27 1/8


1/8 G: Approx. 300 45.9 (Pilot EXH port)
(External pilot port) H: Approx. 600 164.3 <In the case of external pilot type>
(Lead wire length)
3/8, 1/2
[4(A), 2(B) port] 29 30
17.5

L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO):
3 3 3 3
SY9 4 40(R)-L- 03
04 -Q SY9 4 40(R)-M- 03
04 -Q SY9 4 40(R)-D- 03
04 -Q SY9 4 40(R)-WO- 03
04 -Q
5 5 5 5
(Lead wire length)

Applicable cable O.D.


Approx. 300

109.2 ø3.5 to ø7
75.4 101.7
Max. 10

60 90.4
75.4
(Lead wire length) 79.9 M8 x 1
Approx. 300 62.4
86.5
Pg7
113.5

29.5 29.5

29.5
29.5

29.5

120
97.5
204.1

202.3

182.3
184.1

164.5

29.5
29.5

29.5

44.5

44.5
44.5

44.5

15.5 15.5 15.5 15.5


25

17.5 17.5 17.5 17.5


47.5
41
46

54.9
55.8

64.9
65.8

34.5 34.5 34.5 34.5

Note) Refer to back page 12 for


dimensions of connector types.

36
5 Port Solenoid Valve
Series SY3000/5000/7000
Body Ported
Type 20 Bar Stock Type/Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 5 20 05 -Q Example
Cylinder port size
Double solenoid (24 VDC)
SY3220-5G-C6-Q (2 sets)
C6: With one-touch Single solenoid (24 VDC)
fitting for ø6 SY3120-5G-C6-Q (2 sets)
Manifold series Thread type
3 SY3000 - Rc
5 SY5000 00F G Blanking plate assembly
7 SY7000 00N NPT SY3000-26-19A-Q (1 set)
00T NPTF Manifold base (5 stations)

+

+
SS5Y3-20-05-Q

+
EB
Stations –
+

Sta P

02 2 stations tio
ns EA
...
...

...

32
20 20 stations 1

∗ This also includes the


SS5Y3-20-05-Q 1 set (Type 20, 5 station manifold base part no.)
number of blanking
∗ SY3000-26-19A-Q 1 set (Blanking plate assembly part no.)
plate assemblies.
∗ SY3120-5G-C6-Q 2 sets (Single solenoid part no.)
∗ SY3220-5G-C6-Q 2 sets (Double solenoid part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number.
In the case of complex arrangement, specify them on the manifold
specification sheet.

37
SY3000/5000/7000 Body Ported Type 20
How to Order Valve

SY 5 1 20 5 L 01 -Q
Thread type
- Rc
Series F G
3 SY3000 N NPT
5 SY5000 T NPTF
7 SY7000

A, B port size
Type of actuation Thread piping
1 2 position single Applicable
Symbol Port size
2 2 position double Manual override series
3 3 position closed center - Non-locking push type M5 M5 SY3000
4 3 position exhaust center D Push-turn locking slotted type 01 18 SY5000
5 3 position pressure center E Push-turn locking lever type 02 14 SY7000

One-touch fitting (Metric size)


Symbol Port size Applicable
series
Coil specifications C4 One-touch fitting for ø4
SY3000
- Standard C6 One-touch fitting for ø6
Light/surge voltage suppressor
T With power saving circuit (24 VDC, 12 VDC only) Electrical entry for G, H, L, M, W C4 One-touch fitting for ø4
∗ Power saving circuit is not available - Without light/surge voltage suppressor C6 One-touch fitting for ø6 SY5000
in the case of D, DO or W type. S With surge voltage suppressor C8 One-touch fitting for ø8
Z With light/surge voltage suppressor C8 One-touch fitting for ø8
SY7000
R With surge voltage suppressor (Non-polar type) C10 One-touch fitting for ø10
U With light/surge voltage suppressor (Non-polar type)
One-touch fitting (Inch size)
∗ Power saving circuit is only available in the "Z"
Rated voltage type. Symbol Port size Applicable
series
For DC AC ( 50 60 Hz)
N3 One-touch fitting for ø 5 32"
5 24 VDC 1 100 VAC Electrical entry for D (SY5000/7000 only) SY3000
N7 One-touch fitting for ø 1 4"
6 12 VDC 2 200 VAC - Without light/surge voltage suppressor N3 One-touch fitting for ø 32
5 "
V 6 VDC 3 110 VAC [115 VAC] S With surge voltage suppressor (Non-polar type) N7 One-touch fitting for ø 1 4" SY5000
S 5 VDC 4 220 VAC [230 VAC] Z With light/surge voltage suppressor (Non-polar type) N9 One-touch fitting for ø 5 16"
R 3 VDC ∗ DOZ is not available. N9 One-touch fitting for ø 5 16"
∗ DC specifications of type D and DO is only available ∗ For AC voltage valves there is no “S” option. It SY7000
N11 One-touch fitting for ø 3 8"
with 12 and 24 VDC. is already built-in to the rectifier circuit.
∗ AC specification is only available with D and DO type.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 24, 12, 6, 5, 3 VDC
220 VAC
Grommet L plug connector M plug connector DIN terminal Note2) M8 connector ∗
G: Lead wire L: With lead wire M: With lead wire WO: Without
length 300 mm (Length 300 mm) (Length 300 mm) D: With connector connector cable
H: Lead wire LN: Without lead wire MN: Without lead wire DO: Without W: With connector
length 600 mm LO: Without connector MO: Without connector connector cable Note 1) Note) When placing an order for body
∗ LN, MN type: with 2 sockets. ported solenoid valve as a single unit,
∗ For DIN terminal of SY3000 series, refer to back page 10. mounting bolt for manifold and
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) gasket are not attached. Order them
is also available. For details, refer to page 210. separately, if necessary.
∗ For connector cable of M8 connector, refer to back page 12. (For details, refer to catalogue in
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also page 56.)
available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank
referring to back page 13.
Note2) SY5000/7000 only).

38
Type 20 Body Ported
Manifold Specifications

Model SS5Y3-20 SS5Y5-20 SS5Y7-20


Applicable valve SY320 SY520 SY720
Manifold type Single base/B mount
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations Note1)
A, B port location Valve
P, EA, EB port 18 14 14
18
M5 14
Port size C4 (One-touch fitting for ø4)
A, B port C4(One-touch fitting for ø4) C8 (One-touch fitting for ø8)
C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6) C10 (One-touch fitting for ø10)
C8 (One-touch fitting for ø8)
Manifold base weight W (g)
W = 13n + 35 W = 36n + 64 W = 43n + 64
n: Stations
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Option” on page 56.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
SS5Y3-20 18 C6 0.72 0.29 0.18 182 0.80 0.36 0.21 212
SS5Y5-20 14 C8 1.9 0.28 0.48 477 2.2 0.20 0.53 527
SS5Y7-20 14 C10 3.6 0.31 0.93 921 3.6 0.27 0.88 898
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

39
SY3000/5000/7000 Body Ported Type 20
SY3000: SS5Y3-20- Stations - -Q
Grommet (G)
Dimensions when mounting Dimensions when mounting (Station n) (Station 1)
individual EXH spacer individual SUP spacer

(3.2)
( single solenoid. )
(3.2)
SUP port is at the end plate of

(3.2)
(Light/surge voltage suppressor)

EXH port SUP port


C6:45.1
N7:48.9

C6:45.1
N7:48.9
-+
M5 M5
40

-+ (Both sides) -+ -+ -+ -+ -+

C6:54.1
N7:57.9
3 1
11

11

49
6

33.6
20

20

20
0.5 0.5

One-touch fitting L1
(A, B port)
L2 9
Applicable tubing O.D.
: ø4, ø5/32" Manual
: ø6, ø1/4" override

1/8
(P, EA, EB port)

30.7

EB
EB
23.5

23.5
22.2

16
B

B
16.5 16.5

97.3

88.8
49

P
P
22.2

10.2

EA
EA

44.4
12.5

44 4-ø4.5
(Pitch)
(M5 port) (For mounting)
Approx. 300

P = 10.5 19
(Lead wire

M5
(A, B port)
length)

L plug connector (L) M plug connector (M) M8 connector (WO)


M8 x 1
115.3

100.5
117.1

97.5
108.6

106.8

92
89
44.5

46
53.4
54.3

Approx. 300 60.1


(Lead wire length) 36
53.5
(Lead wire length)

33.6
Approx. 300

49
Note) Refer to back page 12 for
dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 48.5 59 69.5 80 90.5 101 111.5 122 132.5 143 153.5 164 174.5 185 195.5 206 216.5 227 237.5
L2 30.5 41 51.5 62 72.5 83 93.5 104 114.5 125 135.5 146 156.5 167 177.5 188 198.5 209 219.5

40
Type 20 Body Ported
SY5000: SS5Y5-20- Stations - -Q
Grommet (G)
Dimensions when mounting Dimensions when mounting
individual EXH spacer individual SUP spacer

(4.9)
( single solenoid.
SUP port is at the end plate of
) (Station n) (Station 1)

(4.9)
(4.9)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+

67.4
EXH port SUP port

59.5
56.4

56.4
-+

55.1
1/4 1/4
44.1

39.7
Both sides Both sides

26.5
-+
E P
15.5

15.5
8

8
1 1 L1
26.5

26.5
L2 10

Manual override
4-ø4.5
(For mounting)
16.5
11.5 (DIN : 32.7) (DIN : 45.3)

(DIN : 32.7)

EB
44

16.2
EB

B
31.4

32.3
14.5

20
30

119.8
21

107.2
60

P
P
21

31.4

EA
EA

53.6
A

A
1/4
(Lead wire length)
Approx. 300

(P, EA, EB port)

(Pitch)
1/8
P = 16 22 (A, B port)
One-touch fitting (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
137.8
139.6

123
120

125.2

110.4
107.4

157.8

159.6
127

145.2

147
53.7

55.2
62.6
63.5

72.6

73.5

66.2
42.1
Approx. 300 M8 x 1 59.6
(Lead wire length)

39.7 (Lead wire length) Pg7 69.1


Max. 10

80.4
Approx. 300

55.1
87.9

Applicable cable O.D.


ø3.5 to ø7 Note) Refer to back page 12 for
dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 60 76 92 108 124 140 156 172 188 204 220 236 252 268 284 300 316 332 348
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328

41
SY3000/5000/7000 Body Ported Type 20
SY7000: SS5Y7-20- Stations - -Q
Grommet (G)
Dimensions when mounting Dimensions when mounting
(Station n) (Station 1)

(5.5)
individual EXH spacer (5.5) individual SUP spacer
( single solenoid.
SUP port is at the end plate of
)

(5.5)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+
EXH port SUP port

74.6
66.6

66.6
-+

67
1/4 1/4

58.5
50.5

43.1
Both sides Both sides
-+

26.5
E P
18.5

18.5
9.5
9.5

1 1 L1
26.5

26.5
L2 10
4-ø4.5
Manual override (For mounting)

16.5
11.5

(DIN: 39.8) (DIN: 52.8)

(DIN: 39.8)
51.5

EB

39.4
38.5

EB
21
19

20
30

134.4
21

121.4
60

P
P
21

38.5

EA
EA

60.7
A

A
1/4
(P, EA, EB port)
(Lead wire length)
Approx. 300

(Pitch)
P = 19 23.5 1/4
(A, B port)
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

M8 x 1
172.4

137.6
154.2

134.6

174.2

152.4
159.4

124.6
141.2

121.6

161.2

139.4

62.3
60.8
70.6

69.7
79.7

80.6

Approx. 300 69.6


45.5
(Lead wire length) 63
43.1 Pg7 74.2
(Lead wire length)

Max. 10

58.5 85.5
Approx. 300

93

Applicable cable O.D.


Note) Refer to back page 12 for
ø3.5 to ø7
dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388

42
5 Port Solenoid Valve
Series SY9000
Body Ported
Type 23 Stacking Type/Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 9 23 05 -Q Example
Cylinder port size Double solenoid (24 VDC)
C12: With one-touch fitting for ø12 SY9220-5LOZ-C12-Q (2 sets)
Manifold series Thread type Single solenoid (24 VDC)
9 SY9000 - Rc SY9120-5LOZ-C12-Q (2 sets)
00F G Blanking plate assembly
00N NPT SY9000-26-1A-Q (1 set)
Valve stations 00T NPTF -+
Manifold base (5 stations)
Symbol Stations
-+

-+ SS5Y9-23-05-Q
02 2 stations Option Sta
tio
-+

ns EB
...

...

Symbol Mounting P

20 20 stations EA
- Direct mounting 3
∗ This also includes the D
2
DIN rail mounting (with DIN rail) 1
number of blanking
D0 DIN rail mounting (without DIN rail)
plate assemblies.
When a longer DIN rail is desired SS5Y9-23-05-Q 1 set (Type 23, 5 station manifold base part no.)
than the specified stations, ∗ SY9000-26-1A-Q 1 set (Blanking plate assembly part no.)
D∗
specify the station number to be ∗ SY9120-5LOZ-C12-Q 2 sets (Single solenoid part no.)
required into ∗ mark. ∗ SY9220-5LOZ-C12-Q 2 sets (Double solenoid part no.)
The asterisk denotes the symbol for assembly.
∗ Type 23 manifold of Series SY9000 is
Prefix it to the part nos. of the solenoid valve, etc.
concurrently used for the internal and
external pilot. Add the valve and option part number under the manifold base part
number. In the case of complex arrangement, specify them on the
manifold specification sheet.

43
SY9000 Body Ported Type 23
How to Order Valve

SY 9 1 20 5 L 02 -Q
Series Thread type
9 SY9000 Nil Rc
F G
N NPT
Type of actuation T NPTF
1 2 position single
2 2 position double
3 3 position closed center
A, B port size
4 3 position exhaust center Thread piping
5 3 position pressure center Symbol Port size
02 14
03 38
Pilot specifications
One-touch fitting (Metric size)
- Internal pilot
Symbol Port size
R External pilot Manual override C8 One-touch fitting for ø8
∗ In the case of external - Non-locking push type
pilot specifications, it
C10 One-touch fitting for ø10
D Push-turn locking slotted type C12 One-touch fitting for ø12
cannot be used as a
single unit. E Push-turn locking lever type
One-touch fitting (Inch size)
Symbol Port size
N9 One-touch fitting for ø 5 16"
Coil specifications N11 One-touch fitting for ø 3 8"
- Standard
T With power saving circuit (24 VDC, 12 VDC only) Light/surge voltage suppressor
∗ Power saving circuit is not available in the Electrical entry for G, H, L, M, W
case of D, DO or W type. - Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
Rated voltage U With light/surge voltage suppressor (Non-polar type)
For DC For AC (50 60 Hz) ∗ Power saving circuit is only available in the
5 24 VDC 1 100 VAC "Z" type.
6 12 VDC 2 200 VAC
V 6 VDC 3 110 VAC [115 VAC]
S 5 VDC 4 220 VAC [230 VAC]
R 3 VDC
∗ DC specifications of type D and DO is only
Electrical entry for D
available with 12 and 24 VDC. - Without light/surge voltage suppressor
∗ AC specification is only available with D and DO type. S With surge voltage suppressor
Z With light/surge voltage suppressor
∗ DOZ is not available.
∗ For AC voltage valves there is no
“S” option. It is already built-in to
the rectifier circuit.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 24, 12, 6,
220 VAC 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector ∗
G: Lead wire L: With lead wire M: With lead wire D: With connector WO: Without connector
length 300 mm (Length 300 mm) (Length 300 mm) DO: Without connector cable
H: Lead wire LN: Without lead wire MN: Without lead wire W: With connector
length 600 mm LO: Without connector MO: Without connector cable Note 1)
∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is
also available. For details, refer to page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available.
For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring
to back page 13.

Note) When placing an order for body ported solenoid valve as a single unit,
mounting bolt for manifold and gasket are not attached. Order them
separately, if necessary.
For details, refer to page 56.

44
Type 23 Body Ported
Manifold Specifications

Model SS5Y9-23
Applicable valve SY920
Manifold type Stacking type
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations Note1)
A, B port location Valve
P, EA, EB port 38
14
38
Port size
A, B port C8 (One-touch fitting for ø8)
C10 (One-touch fitting for ø10)
C12 (One-touch fitting for ø12)
Manifold base weight W (g)
W = 66n + 246
n: Stations
Note 1) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA/EB
port on both sides.
Note 2) Refer to “Manifold Option” on page 56.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 14/2 (PA/B) 4/25/3 (A/BEA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar) ) b Cv Q[l/min/ANR)]* C (dm3/(s·bar) ) b Cv Q[l/min/ANR)]*
SS5Y9-23 38 C12 6.3 0.20 1.5 1509 8.2 0.28 1.9 2059
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

45
SY9000 Body Ported Type 23
SY9000: SS5Y9-23- Stations -(D)-(D)-Q
Grommet (G) (Station n) (Station 1)

(5.5)
Individual EXH spacer is Individual SUP spacer (Light/surge voltage suppressor)
mounted is mounted
(SUP port is at the end plate of

(5.5)

(5.5)
single solenoid.)
-+ -+ -+ -+ -+

92.5

83
72.4
57
- +
1/4

31.5
81

1/4 (Both sides)

81
(SUP port)
60.9

- +
EXH port
45.5

P 1 E 5

20
20

10
10

(13.8)
L1
using DIN rail)

1 1
(Height when

L2 5
(Rail mounting hole pitch: 12.5)
L3 L4
M5
L5 15 (External pilot port)
Manual override <In the case of external pilot>
DIN rail holding screw DIN rail 13.5 13.5
13.8 <When attaching the DIN rail>
Tightening torque: 0.55 to 0.65N·m
(DIN: 69.5)

(DIN: 53)
68.2

X
X

56.3
2B

2B
2B

2B
2B
51.7

5.5
48.3
3EB

38.1
35
25.5 25.5

164.3

16.3

33.6
25

147.8
96.6
1 P

38.1
(DIN: 53)
51.7

Z
5EA

73.9
4A

4A
4A

4A

4A

PE
PE

3/8
(Lead wire length)

4-ø6.3
[1(P), 3 (EB), 5(EA) port]
Approx. 300

(For mounting)
M5
1/4, 3/8 P = 24 36 (Pilot EXH port)
One-touch fitting
[4(A), 2(B) port] (Pitch)
[4(A), 2(B) port]
Applicable tubing O.D.: ø8, ø5/16"
: ø10, ø3/8"
: ø12

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

M8 x 1
3EB

202.3

204.1

182.3

167.5
3EB

164.5

3EB

3EB
184.1

165.8
185.8

187.6
167.6

151
148
1P
1P

1P

1P
5EA
5EA

82.9

75.5
5EA

5EA
74

92.9

93.8
83.8

59.4
83.5 87.4 76.9
(Lead wire length)

Pg7
Max. 10

Approx. 300 98.7


Approx. 300

57 (Lead wire length) 106.2


72.4
Note) Refer to back page 12 for
Applicable cable O.D. dimensions of connector types.
ø3.5 to ø7

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 123 148 173 198 223 248 273 298 323 335.5 360.5 385.5 410.5 435.5 460.5 485.5 510.5 535.5 560.5
L2 112.5 137.5 162.5 187.5 212.5 237.5 262.5 287.5 312.5 325 350 375 400 425 450 475 500 525 550
L3 96 120 144 168 192 216 240 264 288 312 336 360 384 408 432 456 480 504 528
L4 13.5 14 14.5 15 15.5 16 16.5 17 17.5 12 12.5 13 13.5 14 14.5 15 15.5 16 16.5
L5 66 90 114 138 162 186 210 234 258 282 306 330 354 378 402 426 450 474 498
Note) In the case of direct mounting without DIN rail, total width of manifold is L3.

46
5 Port Solenoid Valve
Series SY3000/5000/7000
Body Ported
Type 20P Bar Stock Type/Flat Ribbon Cable
How to Order Manifold How to Order Valve Manifold Assembly (Example)

Example
SS5Y 5 20P 05 -Q Cylinder port size
Double solenoid (24 VDC)
SY3220-5LOU-C6-Q(2set)
C6: With one-touch fitting for ø6
(Single solenoid) Connector assembly Single solenoid (24 VDC)
SY3000-37-3A SY3120-5LOU-C6-Q (3set)
Manifold series Thread type
(Double solenoid) Connector assembly Blanking plate assembly
3 SY3000 - Rc
SY3000-37-4A SY3000-26-20A-Q (1set)
5 SY5000 00F G
7 SY7000 00N NPT Manifold base (5 stations)
00T NPTF SS5Y3-20P-06-Q
Sta EB
Stations tio
ns P

03 3 stations EA

3
...

...

2
12 12 stations 1
Note) SS5Y3 has 4
to 12 stations.
SS5Y3-20P-06-Q 1 set (Type 20P, 6 station manifold part no.)
∗ SY3000-26-20A-Q 1 set (Blanking plate assembly part no)
∗ SY3120-5LOU-C6-Q 3 sets (Single solenoid part no.)
∗ SY3220-5LOU-C6-Q 2 sets (Double solenoid part no.)
∗ SY3000-37-3A 3 sets (Connector assembly part no.)
∗ SY3000-37-4A 2 sets (Connector assembly part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.

Add the valve and option part number under the manifold base part number.
In the case of complex arrangement, specify them on the manifold
specification sheet.

47
SY3000/5000/7000 Body Ported Type 20P
How to Order Valve
Light/surge voltage suppressor
Rated voltage Z With light/surge voltage suppressor
5 24 VDC With light/surge voltage suppressor
U
6 12 VDC (Non-polar type)
Note) Z: Positive common
specifications only.

For DC: SY 5 1 20 5 LO Z 01 -Q

Series Thread type


3 SY3000 - Rc
5 SY5000 F G
7 SY7000 N NPT
T NPTF
∗ Except for M5
Type of actuation A, B port size
1 2 position single Thread piping One-touch fitting (Inch size)
2 2 position double Symbol Port size Applicable series Symbol Port size Applicable series
3 3 position closed center M5 M5 SY3000 N3 One-touch fitting for ø 5 32"
SY3000
4 3 position exhaust center 01 18 SY5000 N7 One-touch fitting for ø 1 4"
5 3 position pressure center 02 14 SY7000 N3 One-touch fitting for ø 5 32"
One-touch fitting (Metric size) N7 One-touch fitting for ø 1 4" SY5000
Symbol Port size Applicable series N9 One-touch fitting for ø 5 16"
C4 One-touch fitting for ø4 N9 One-touch fitting for ø 5 16"
SY3000 SY7000
C6 One-touch fitting for ø6 N11 One-touch fitting for ø 3 8"
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6 SY5000 Note) When placing an order for body ported
C8 One-touch fitting for ø8 solenoid valve as a single unit, mounting
Manual override bolt for manifold and gasket are not
C8 One-touch fitting for ø8
- Non-locking push type SY7000 attached. Order them separately, if
C10 One-touch fitting for ø10
D Push-turn locking slotted type necessary.
E Push-turn locking lever type (For details, refer to page 56.)

48
Type 20P Body Ported
Manifold Specifications
 Multiple valve wiring is
simplified through the use Model SS5Y3-20P SS5Y5-20P SS5Y7-20P
of the flat cable connector Applicable valve SY320 SY520 SY720
Manifold type Single base/B mount
 Clean appearance P (SUP)/R (EXH) Common SUP, Common EXH
In the case of a flat ribbon cable type, each Valve stations 4 to 12 stations(1) 3 to 12 stations Note 1)
valve is wired on the print board of manifold A, B port location Valve
base to allow the external wiring to be piped all 18 14 14
P, EA, EB port
together with 26 pins MIL connector. 18
M5, 14
Port size C4 (One-touch fitting for ø4)
A, B port C4 (One-touch fitting for ø4) C8 (One-touch fitting for ø8)
C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6) C10 (One-touch fitting for ø10)
C8 (One-touch fitting for ø8)
Manifold base weight W (g)
W = 19n + 45 W = 43n + 77 W = 51n + 81
n: Stations
Applicable flat ribbon cable connector Flat ribbon cable connector, Socket: 26 pins MIL type with strain relief, Conforming to MIL-C-83503
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its
equivalent.
Note 3) Refer to “Manifold Option” on page 56.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv Q[l/min(ANR)]* C [dm3/(s·bar)] b Cv Q[l/min(ANR)]*
SS5Y3-20P 18 C6 0.72 0.29 0.18 182 0.80 0.36 0.21 212
SS5Y5-20P 14 C8 1.9 0.28 0.48 477 2.2 0.20 0.53 527
SS5Y7-20P 14 C10 3.6 0.31 0.93 921 3.6 0.27 0.88 898
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.
How to Order Connector Assembly
Internal Wiring of Manifold (Non-polar type)
For 12, 24 VDC
For DC For SY3000 For SY5000/7000
For single solenoid: SY3000-37-3A SY5000-37-3A Station 12 Station 4 Station 3 Station 2 Station 1
Double solenoid, Coil
3 position type SY3000-37-4A SY5000-37-4A
Single with
spacer assembly SY5000-37-3A SY5000-37-5A
Double, 3 position Triangle mark
with spacer assembly SY3000-37-6A SY5000-37-6A
position

Caution Note)
Connector
• For non-polar (U) valves, the electrical DC
connections can be used with either positive
and negative COM. For type (Z), only use with
Connected on PCB Common (–) (+)
Common (–) (+)

Station 12 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 4 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 3 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 2 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 1 Solenoid B (+) (–)


Solenoid A (+) (–)

positive COM as the valve does not operate


correctly when used with negative COM.
{
{

(Max. 12 stations) Triangle mark


Note)
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown in
the reference, means a correlation of 1, 2, 3····26 from the
Reference figure
triangle mark side on the flat ribbon cable of connector.
• For more than 10 stations, both poles of the Station

common should be wired. Solenoid B side


• For single solenoid, connect to the solenoid A side.
• The maximum number of stations that can be
accommodated is 12. For more stations, please Wiring unit Solenoid A side
contact SMC.

49
SY3000/5000/7000 Body Ported Type 20P
SY3000: SS5Y3-20P- Stations --Q

(Station n) (Station 1)

(3.2)
(Light/surge voltage suppressor)

C6: 54.1
N7: 57.9

49
26.6
20
28.5

5.8
Applicable connector: 26 pins MIL type
with strain relief
(Conforming to MIL-C-83503)

L1
44 Manual override L2 4
M5 port
- +

- +

1/8 M5 4-ø4.5
7.2

12.5
P, EA, EB port (A, B port) (For mounting)

16 15.5
18.4

EB
1.3
23.5

EB
B

B
16.5 16.5

117.1
108.6
45.7
49

P
10.2

77.8
82.8
A

A
EA

EA
14

- + - + - + - + - +

One-touch fitting
(Pitch) Triangle mark
A, B port P=12.5 18.5
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4"

Stations n 4 5 6 7 8 9 10 11 12
L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

50
Type 20P Body Ported
SY5000: SS5Y5-20P- Stations --Q

(Station n) (Station 1)

(4.9)
(Light/surge voltage suppressor)

67.4

59.5
55.1

36.2
7.3
26.5
28.5
Applicable connector: 26 pins MIL type
with strain relief
(Conforming to MIL-C-83503)

L1
L2 5
(Pitch)
P=17.5 21
-+ 1/8
(A, B port)
4-ø4.5
-+

16.5 Manual override


(For mounting)
11.5

2.3
44

EB

EB
31.4
14.5
30

139.6
21

16.2
127
60

20
P

P
21

31.4

93.8
EA

EA
A

A
63.5

1/4
(P, EA, EB port)
-+ -+ -+ -+ -+

Triangle mark
One-touch fitting
A, B port
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"

Stations n 3 4 5 6 7 8 9 10 11 12
L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5

51
SY3000/5000/7000 Body Ported Type 20P
SY7000: SS5Y7-20P- Stations --Q

(5.5)
(Light/surge voltage suppressor)

74.6
58.5

67
38.1
8.8
26.5
28.5
Applicable connector: 26 pins MIL type
with strain relief
(Conforming to MIL-C-83503)

L1
L2 10
Manual
(Pitch)
override P=20.5 23.5
-+

-+ 1/4
A, B port
16.5

9.4
11.5
51.5
38.5

B
EB

EB
19

20
30

154.2
21

21
141.2
60

P
21

93.8
38.5

EA

EA
A

A
70.6

1/4 4-ø4.5
(P, EA, EB port) (For mounting)
-+ -+ -+ -+ -+
Triangle mark
One-touch fitting
A, B port
Applicable tubing O.D.: ø8, ø5/16" (Station n) (Station 1)
ø10, ø3/8"

Stations n 3 4 5 6 7 8 9 10 11 12
L1 88 108.5 129 149.5 170 190.5 211 231.5 252 272.5
L2 68 88.5 109 129.5 150 170.5 191 211.5 232 252.5

52
5 Port Solenoid Valve
Series SY9000
Body Ported
Type 23P Stacking Type/Flat Ribbon Cable
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 9 23P 05 -Q Example Cylinder port Port size


C12: One-touch fitting for ø12
Double solenoid (24 VDC)
(Single solenoid) Connector assembly SY9220-5LOU-C12-Q (2 sets)
Manifold series Thread type SY9000-37-1A Single solenoid (24 VDC)
(Double solenoid) Connector assembly SY9120-5LOU-C12-Q (2 sets)
9 SY9000 - Rc Blanking plate assembly
SY9000-37-2A
00F G SY9000-26-3A-Q (1 set)
00N NPT Manifold base (5 stations)
Valve stations 00T NPTF
Sta
tio
SS5Y9-23P-05-Q
ns
Symbol Stations
3
04 4 stations 2
Option 1
...

,..

12 12 stations Symbol Mounting


∗ This also includes the - Direct mounting SS5Y9-23P-05-Q 1 set (Type 23, 5 station manifold base part no.)
number of blanking D DIN rail mounting (with DIN rail) ∗ SY9000-26-3A-Q 1 set (Blanking plate assembly part no.)
plate assemblies. D0 DIN rail mounting (without DIN rail) ∗ SY9120-5LOU-C12-Q 2 sets (Single solenoid part no.)
∗ SY9220-5LOU-C12-Q 2 sets (Double solenoid part no.)
When a longer DIN rail is desired than
∗ SY9000-37-1A 2 sets (Connector assembly part no.)
D ∗ the specified stations, specify the station ∗ SY9000-37-2A 2 sets (Connector assembly part no.)
∗ Type 23P manifold of Series
SY9000 is concurrently used for number to be required into ∗ mark.
The asterisk denotes the symbol for assembly.
the internal and external pilot. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part
number. In the case of complex arrangement, specify them on the
manifold specification sheet.

How to Order Valve

Light/surge voltage suppressor


Z With light/surge voltage suppressor

Rated voltage With light/surge voltage suppressor


U (Non-polar type)
5 24 VDC
Note) Z: Positive common specifications only.
6 12 VDC

For DC: SY 9 1 20 5 LO Z 02 -Q
Thread type
- Rc
F G
Series N NPT
9 SY9000 T NPTF

Type of actuation A, B port size


Thread piping
1 2 position single
2 2 position double Symbol Port size
3 3 position closed center 02 14

4 3 position exhaust center 03 38

5 3 position pressure center One-touch fitting (Metric size)


Pilot specifications Symbol Port size
C8 One-touch fitting for ø8
- Internal pilot
External pilot C10 One-touch fitting for ø10
R
C12 One-touch fitting for ø12
∗ Type 23P manifolds can
be used for both internal One-touch fitting (Inch size)
and external pilots. Symbol Port size
N9 One-touch fitting for ø 5 16"
N11 One-touch fitting for ø 3 8"

Manual override
- Non-locking push type Note) When placing an order for body ported solenoid valve as a single unit,
D Push-turn locking slotted type mounting bolt for manifold and gasket are not attached. Order them separately,
E Push-turn locking lever type if necessary. (For details, refer to page 56.)

53
SY9000 Body Ported Type 23P
Manifold Specifications
 Multiple valve wiring is simplified through
the use of the flat cable connector. Model SS5Y9-23P
Applicable valve SY920
 Clean appearance Manifold type Stacking type
In the case of a flat ribbon cable type, each valve is
wired on the print board of manifold base to allow P (SUP)/R (EXH) Common SUP, Common EXH
the external wiring to be piped all together with 26 Valve stations 4 to 12 stations Note1)
pins MIL connector. A, B port location Valve
P, EA, EB port 38
14
38
Port size
A, B port C8 (One-touch fitting for ø8)
C10 (One-touch fitting for ø10)
C12 (One-touch fitting for ø12)
Manifold base weight W (g)
W = 73n + 259
n: Stations
Applicable flat ribbon cable connector Flat ribbon cable connector, Socket: 26 pins MIL with strain relief, Conforming to MIL-C-83503
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 12, 24 VDC
Note 1) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its equivalent.
Note 3) Refer to “Manifold Option” on page 56.

How to Order Connector Assembly Flow Characteristics


For 12, 24 VDC Port size Flow characteristics
Specifications For SY9000 Model 1 ,5 ,3 4 ,2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
For single solenoid SY9000-37-1A (P ,EA ,EB) (A ,B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
Double solenoid SY9000-37-2A SS5Y9-23P 38 C12 6.3 0.20 1.5 1509 8.2 0.28 1.9 2059
3 position
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
Single SY9000-37-3A * These values have been calculated according to ISO6358 and represent the flow rate measured
with spacer assembly in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.
Double, 3 position SY9000-37-4A
with spacer assembly Internal Wiring of Manifold (Non-polar type)

Station 12 Station 4 Station 3 Station 2 Station 1


Coil

Triangle mark
position

Note)
Connector
Connected on PCB Common (–) (+)
Common (–) (+)

Station 12 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 4 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 3 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 2 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 1 Solenoid B (+) (–)


Solenoid A (+) (–)
{
{

(Max. 12 stations)
Note)
Triangle mark
Terminal no. is not indicated on the connector. The
terminal no. indicated in the connection schematic of
connector, as shown in the reference, means a
correlation of 1, 2, 3····26 from the triangle mark side on
the flat ribbon cable of connector. Reference figure

• For more than 10 stations, both poles of the common should be wired.
• For single solenoid, connect to the solenoid A side.

Caution • The maximum number of stations that can be accommodated is 12. For more stations, please contact SMC.
Station
• For non-polar (U) valves, the electrical DC Solenoid B side
connections can be used with either positive
and negative COM. For type (Z), only use with
positive COM as the valve does not operate Wiring unit
Solenoid A side
correctly when used with negative COM.
54
Type 23P Body Ported
SY9000: SS5Y9-23P- Stations --(D)-Q

Grommet (G)

(5.5)
(Station n) (Station 1)
(Light/surge voltage suppressor)

-+ -+ -+ -+ -+

92.5
72.4

83
42.2
31.5

15.5
Applicable connector: 26 pins MIL type 52.5

(Height when using


With strain releaf
(Conforming to MIL-C-83503)
(13.8)

DIN rail)
L1
L2 5
(Rail mounting hole pitch: 12.5)
L3 L4 M5
13.5 L5 15 (Pilot EXH port)
(Pitch) <In the case of external pilot>
P=24 21 13.5
-+
Manual override
DIN rail holding screw -+

13.8 <When attaching the DIN rail>


Tightening torque: 0.55 to 0.65 N·m DIN rail
68.2

X
X

56.3
2B

2B
2B

2B

2B
51.7
48.3

5.5

38.1
25.5 25.5

35
3EB

33.6
16.3

25
96.6

184.1

167.6
8
130.4
1P

38.1
51.7

4A

4A
4A

4A

4A
5EA

PE
PE
83.8

-+ -+ -+ -+ -+

3/8 4-ø6.3 Triangle mark


1/4, 3/8
[1(P), 3 (EB), 5(EA) port] [Mounting hole when not using DIN rail] [4(A), 2(B) port]
M5
(Pilot EXH port)
<In the case of external pilot>
One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8"
: ø12

Stations n 4 stations 5 6 7 8 9 10 11 12 stations


L1 173 198 223 248 273 298 323 335.5 360.5
L2 162.5 187.5 212.5 237.5 262.5 287.5 312.5 325 350
L3 144 168 192 216 240 264 288 312 336
L4 14.5 15 15.5 16 16.5 17 17.5 12 12.5
L5 114 138 162 186 210 234 258 282 306
Note) In the case of direct mounting without DIN rail, total width of manifold
is L3.

55
SY9000 Body Ported Type 20 20P Type

Type 23 23P Type

Manifold Option

 Type 20, 23  Type 20P, 23P  Gasket assembly part no.


Blanking plate assembly Blanking plate assembly Round head
combination screw

Gasket

Series Assembly part no. Series Assembly part no. Series Gasket assembly
SY3000 SY3000-26-19A-Q SY3000 SY3000-26-20A-Q SY3000 SY3000-GS-1
SY5000 SY5000-26-1A-Q SY5000 SY5000-26-3A-Q SY5000 SY5000-GS-1
SY7000 SY7000-26-1A-Q SY7000 SY7000-26-3A-Q SY7000 SY7000-GS-1
SY9000 SY9000-26-1A-Q SY9000 SY9000-26-3A SY9000 SY9000-GS-1
Note) Gasket assembly
consists of mounting
screws and a gasket.

 Individual SUP spacer assembly  Individual EXH spacer assembly  Individual SUP spacer assembly
+ Individual EXH spacer assembly
(Double spacer)

t t

SUP port EXH port


(Both sides)

Series Assembly part no. Port size t Series Assembly part no. Port size t 5
E5

SY3000 SY3000-38-20A-Q M5 10.5 SY3000 SY3000-39-20A-Q M5 10.5 EXH port


SY5000 SY5000-38-1∗A-Q 18 15 SY5000 SY5000-39-1∗A-Q 18 15 (Both sides)
SY7000 SY7000-38-1∗A-Q 14 18 SY7000 SY7000-39-1∗A-Q 14 18 P1

SY9000 SY9000-38-1∗A-Q 14 20 SY9000 SY9000-39-1∗A-Q 14 20 1

SUP port
Note) • The SUP port of SY3000/5000/ Note) In case of 20P and 23P, for
7000 may be either on the lead protection of the wiring unit section
wire side or on the end plate side. from drainage, piping at the EA port
(An assembly is shipped under the should be arranged so that it will not
conditions shown in the figure.) be directly exposed to exhaust from
• The end plate side is only available the valve.
to SY9000.
[: Available : Not available]
Individual SUP + Applicable manifold types
Series Individual EXP Port size
Caution ∗ Thread type Assemble part no. 20 20P
SY3000 SY3000-120-1A-Q M5  
Mounting screw tightening torques - Rc
F G SY5000 SY5000-75-2∗A-Q 1/8  
M2: 0.16 N·m N SY7000 SY7000-73-3∗A-Q 1/4  
NPT
M3: 0.8 N·m T NPTF Note) The SUP spacer's port does not have an orientation. As for
M4: 1.4 N·m the EXH ports, adjust the symbol “5” to the pilot valve side.
Also, please make sure to connect the individual ports to
Warning protect the wiring section of the pilot valve from drainage, etc.
The individual SUP spacer and EXH spacer can be mounted
When mounting a valve or spacer on the either on the upper side or lower side. (The above illustration
manifold base or sub-plate, etc., those shows the condition when the product is shipped out from a
mounting directions are determined. If factory already assembled.)
mounted in the wrong direction, the
equipment to be connected may cause
malfunction. Refer to external dimensions,
and then mount it.
56
Type 20 20P Body Ported
Type

Type 23 23P Type

Manifold Option
 SUP blocking disk (For SY9000) Cable assembly (For 20P, 23P)

1
By installing a SUP blocking disk in the pressure supply passage of a manifold AXT100-FC26- |
valve, it is possible to supply two or more different high and low pressures to 3 Red
one manifold.

Series No.
SY9000 SY9000-61-2A

 EXH blocking disk (For SY9000) Terminal


By installing an EXH blocking disk in the exhaust passage of a manifold valve, number
it is possible to divide the valve’s exhaust so that it does not affect another
valve. (Two blocking disks are needed to divide both exhausts.)

Connector Assembly for Flat Ribbon Cables


Series No. Cable length (L) Assembly part no. Note
SY9000 SY9000-61-2A 1.5 m AXT100-FC26-1
Cable 26 core x 28 AWG
3m AXT100-FC26-2
5m AXT100-FC26-3
∗ For other commercial connectors, use a 26 pins with strain relief
 Label for blocking disk (For SY9000) conforming to MIL-C-83503.
The labels shown below are used on manifold stations containing SUP/EXH
blocking disk(s) to show their location. (3 pcs. each)

VZ3000-123-1A Connector manufacturers’ example


Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
• Hirose Electric Company
• Japan Aviation Electronics Industry, Ltd.
• Sumitomo 3M Limited
• J.S.T. Mfg. Co., Ltd.
• Fujitsu Limited

∗ When a block disk is concurrently ordered by specifying on the


manifold specification sheet, etc., a label will be stuck on the position
where block disk is mounted.
 Plug (white)
 DIN Rail Dimensions/Weight for SY9000
These are inserted in unused cylinder ports and SUP, EXH ports.
VZ1000 11 4 Note) Purchasing order is available in units of 10 pieces.
Refer to L dimensions
∗ Fill in  with an appropriate no. listed on the
table of DIN rail dimensions shown below.
L (10)
8
Dimensions
Applicable fittings size ød Model A L D
(24)
(35)

KQ2P-04
5.5

4 16 32 6
6 KQ2P-06 18 35 8
8 KQ2P-08 20.5 39 10
Rail mounting pitch 12.5 10 KQ2P-10 22 43 12
12 KQ2P-12 24 44.5 14
No. 0
1 2 3 4 5 6 7 8 9 1 8" KQ2P-01 16 31.5 5
L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 5 32" KQ2P-03 16 32 6
Weight (g) 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 1 4" KQ2P-07 18 35 8.5
No. 1011 12 13 14 15 16 17 18 19 5 16" KQ2P-09 20.5 39 10
L Dimension 223235.5 248 260.5 273 285.5 298 310.5 323 335.5 3 8" KQ2P-11 22 43 11.5
Weight (g) 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7 84.9
No. 20 21 22 23 24 25 26 27 28 29
L Dimension 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5
Weight (g) 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5
Note) ·For DIN rail, refer to page 223.
·Refer to L1 dimension on pages starting with page 55 for lengths that
correspond to the number of manifold stations.

57
SY9000 Body Ported Type 23 23P Type

How to Increase Manifold Bases (Series SY9000 only) Manifold case can be added at any location.

When a type 23 manifold base is added, tension bolts as well as manifold block assembly will be required. Order the tension bolt suitable for the stations
after a station was increased (decreased), since the length of a tension bolt differs by the number of stations. (For changing the number of stations for a
type 23P manifold, wiring unit for the stations and lead assembly will be required.)
1 Loosen the tension bolts t connecting the manifold base, and pull out both of 2 tension bolts.
(When equipped with a DIN rail, loosen one DIN rail holding screw on either U side or D side.)
2 Separate the blocks at the location where station expansion is desired.

3 Mount additional manifold block assembly.

4 Press block-to-block so that there's no gap. After connection, insert a tension bold for desired stations and then tighten it.

Caution (Tightening torque: 2.9 N·m)


(When equipped with a DIN rail, be sure to tighten the DIN rail holding screws after tightening the tension bolts. Tightening torque: 1.4 N·m)

Caution
1. Be sure to shut off the power and air supplies before disassembly. Furthermore, since air may remain inside the actuator, piping and
manifold, confirm that the air is completely exhausted before performing any work.
2. When disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end
block’s holding screw, is inadequate.
3. By adding wiring unit assembly to type 23 manifold, it can be changed to type 23P manifold, too.

Body Ported Manifold Exploded View, 23/23P Common


As for body ported manifold, it is available only for Series SY9000 to disassemble or
increase the manifold.
re
U side
y

i

+
o
u

+


+

!1
DIN rail holding screw
∗ Included only with the DIN rail
w ∗ There is not the case
mounting type (with DIN rail). for direct mount type.

!3 !2
Replacement Parts
U side
No. Description No. Note
1 Manifold block assembly SY9000-50-1A !0
2 D side SUP/EXH block assembly SY9000-51-2A Common use for the internal pilot and external pilot
3 U side SUP/EXH block SY9000-51-4 Common use for the internal pilot and external pilot ∗ Included only withthe DIN
rail mounting style.
4 Hexagon nut SY9000-25-1 M5 x 0.8
5 Since  at the end of part number corresponds with the number
Tension bolt SY9000-23-
of stations, fill in the same number as the number of stations.
6 SUP Block bush assembly SY9000-61-1A Included in the Manifold block assembly and the D side SUP/EXH block assembly.
7 SUP Block bush assembly SY9000-61-3A Included in the Manifold block assembly and the D side SUP/EXH block assembly.
8 Round head combination screw SY9000-18-2 Included in the Manifold block assembly.
9 Manifold gasket SY9000-11-1 Included in the Manifold block assembly.
10 Clamp sub assembly SY9000-29-1A
11 DIN rail VZ1000-11-4- Refer to p. 57.
12 Wiring unit assembly Since  in part number corresponds with the number of
SY9000-36-A
stations, fill in the number of stations (4 to 12).
13 Connector assembly SY9000-37- Refer to page 54.
58
5 Port Solenoid Valve
Series SY3000/5000/7000
Body Ported
Type 60 Cassette Type
How to Order

SS5Y 3 60 05 D -Q
Option
When a DIN rail longer than standard is required,
Series Valve stations enter the number of manifold stations that
3 SY3000 02 2 stations corresponds with the length of DIN rail needed.
Max. 20 stations
5 SY5000

...

...
7 SY7000 20 20 stations
SUP/EXH block assembly mounting position
Symbol Mounting position Applicable stations
U U side
2 to 10 stations
D D side
B Both sides 2 to 20 stations
M* Special location
∗ For special specifications, indicate separately
by the manifold specification sheet.

How to Order Valve Manifold Assembly (Example)

Example Cylinder port size Double solenoid (24 VDC)


M5: M5 SY3260-5G-C6-Q (2 sets)
Cylinder port size Single solenoid (24 VDC)
C6: With one-touch fitting for ø6 SY3160-5G-M5-Q (2 sets)

Manifold base (4 stations)


R SS5Y3-60-04U-Q
D

R port
si
de

–+
–+ C8: With one-touch fitting for ø8
P

1 P port
2
C8: With one-touch fitting for ø8
nS
tati
ons
U
si
de

SS5Y3-60-04U-Q 1 set (Type 60, 4 station manifold base part no.)


∗ SY3260-5G-C6-Q 2 sets (Double solenoid part no.)
∗ SY3160-5G-M5-Q 2 sets (Single solenoid part no.)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number. In the case of complex arrangement, specify
them on the manifold specification sheet.

59
SY3000/5000/7000 Body Ported Type 60
Manifold Specifications

Model SS5Y3-60 SS5Y5-60 SS5Y7-60


Applicable valve SY360 SY560 SY760
Manifold type Stacking type/DIN rail mounted
P (SUP)/R (EXH) Common SUP/Common EXH
Valve stations 2 to 20 stations Note 1)
A, B port location Valve
P, R port C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10) C12 (One-touch fitting for ø12)
M5 1/8 1/4
Port size C4(One-touch fitting for ø4) C4 (One-touch fitting for ø4) C8 (One-touch fitting for ø8)
A, B port
C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6) C10 (One-touch fitting for ø10)
C8 (One-touch fitting for ø8)
Manifold base weight W (g)Note 2)
W = 13n + m + 36 W = 41.2n + m + 77.6 W = 65.4n + m + 128.2
(n: Number of SUP/EXH blocks, m: Weight of DIN rail)
Note 1) In cases such as those where many valves are operated simultaneously, use “- station B (SUP/EXH block on both sides)” (both sides SUP/EXH),
applying pressure to the P ports on both sides and exhausting from the R ports on both sides.
Note 2) For DIN rail weight, refer to page 67.

Flow Characteristics

Port size Flow characteristics


Model 1,5/3 4,2 1  4/2(P  A/B) 4/2  5/3(A/B  R)
(P,R) (A,B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
M5 0.55 0.29 0.14 139 0.72 0.24 0.18 176
SS5Y3-60 C8 C4 0.57 0.24 0.14 140 0.71 0.20 0.17 170
C6 0.68 0.28 0.17 171 0.77 0.24 0.19 189
1/8 1.8 0.24 0.44 441 2.1 0.17 0.47 495
SS5Y5-60 C10 C6 1.5 0.30 0.37 381 2.0 0.16 0.46 469
C8 1.8 0.20 0.45 431 2.2 0.17 0.50 518
1/4 3.7 0.25 0.96 912 3.8 0.19 0.94 905
SS5Y7-60 C12 C8 3.2 0.26 0.81 794 4.0 0.18 0.96 947
C10 3.7 0.28 0.98 929 4.1 0.19 1.0 977
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

60
Type 60 Body Ported
How to Order Valve

SY 3 1 60 5 L C6 -Q
A, B port size
Thread piping
Symbol Port size Applicable series
Series
M5 M5 SY3000
3 SY3000
01 1 /8 SY5000
5 SY5000
02 1/4 SY7000
7 SY7000
One-touch fitting (Metric size) One-touch fitting (Inch size)
Type of actuation
Symbol Port size Applicable series Symbol Port size Applicable series
2 position single
(A) (B) C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
1 4 2 SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1/4"
5 1 3 C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
(EA) (P)(EB)
C6 One-touch fitting for ø6 SY5000 N7 One-touch fitting for ø1/4" SY5000
2 position double
(A) (B) C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16"
2 4 2
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/16"
SY7000 SY7000
5 1 3 C10 One-touch fitting for ø10 N11 One-touch fitting for ø3/8"
(EA) (P)(EB)

3 position closed center


(A) (B)
Manual override
3 4 2

5 1 3
-: Non-locking push D: Push-turn locking E: Push-turn locking
(EA) (P)(EB) type slotted type lever type
3 position exhaust center
(A) (B)
4 2
4
5 1 3
(EA) (P)(EB)

3 position pressure center


(A) (B)
4 2
5
5 1 3
(EA) (P)(EB)

Coil specifications Light/surge voltage suppressor


- Standard Electrical entry for G, H, L, M, W Electrical entry for D (SY5000/7000 only)
T With power saving circuit (24 VDC, 12 VDC only) - Without light/surge voltage suppressor - Without light/surge voltage suppressor
∗ Power saving circuit is not S With light/surge voltage suppressor S With surge voltage suppressor (Non-polar type)
available in the case of D, DO Z With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type)
or W type. R With surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S”
U With light/surge voltage suppressor (Non-polar type) option. It is already built-in to the
∗ Power saving circuit is only available in the rectifier circuit.
"Z" type. ∗ DOZ is not available.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC
Grommet L plug connector M plug connector DIN terminal M8 connector ∗
Rated voltage G: Lead wire L: With lead wire M: With lead wire MN: Without lead (SY5000, 7000) WO: Without
For DC length 300 mm (Length 300 mm) (Length 300 mm) wire D: With connector connector cable
5 24 VDC
6 12 VDC +- +-

V 6 VDC
S 5 VDC -+ -+

R 3 VDC

For AC (50/60Hz)
H: Lead wire LN: Without LO: Without MO: Without DO: Without W: With connector
1 100 VAC length 600 mm lead wire connector connector connector cable Note 1)
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
-+
∗ DC specifications of type D and DO -+

is only available with 12 and 24 VDC.


∗ AC specification is only available with
D and DO type.
∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available.
For details, refer to page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back page 13.
61
SY3000/5000/7000 Body Ported Type 60
Specifications Response Time
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil
Series SY3000 SY5000 SY7000 temperature: 20°C, at rated voltage)
Fluid Air
SY3000
Internal pilot 2 position single 0.15 to 0.7
Response time (ms) (at the pressure of 0.5 MPa)
Operating pressure 2 position double 0.1 to 0.7 Type of
Without surge voltageWith surge voltage suppressor
range (MPa) 3 position 0.2 to 0.7 actuation
suppressor S, Z type R, U type
Ambient and fluid temperature (°C) Max. 50
2 position single 12 or less 15 or less 12 or less
Max. operating 2 position double 10 5 5
10 or less 13 or less 10 or less
2 position double
frequency (Hz) 3 position 3 3 3
3 position 15 or less 20 or less 16 or less
Non-locking push type,
Manual override Push-turn locking slotted type, SY5000
(Manual operation) Push-turn locking lever type
Response time (ms) (at the pressure of 0.5 MPa)
Pilot exhaust method Common exhaust type for main and pilot valve Type of
Without surge voltageWith surge voltage suppressor
Lubrication Not required actuation
suppressor S, Z type R, U type
Mounting position Unrestricted 19 or less 26 or less 19 or less
2 position single
Impact/Vibration resistance Note) 150/30
18 or less 22 or less 18 or less
2 position double
Enclosure Dust proof (∗ DIN terminal, M8 connector: IP65)
3 position 32 or less 38 or less 32 or less
Note) Impact resistance: No malfunction occurred when it is tested in the
axial direction and at the right angles to the SY7000
main valve and armature in both energised and
de-energised states every once for each Response time (ms) (at the pressure of 0.5 MPa)
Type of
condition. Without light/surgeWith light/surge voltage suppressor
Vibration resistance: No malfunction occurred in a one-sweep test
actuation
voltage suppressor S, Z type R, U type
between 45 and 2000 Hz.
Test was performed at both energised and de- 2 position single 31 or less 38 or less 33 or less
energised states in the axial direction and at 2 position double 27 or less 30 or less 28 or less
the right angles to the main valve and 3 position 50 or less 56 or less 50 or less
armature. (Values in the initial stage)
∗ Based on IEC60529

Solenoid Specifications

Grommet (G), (H)


L plug connector (L)
M plug connector (M)
Electrical entry
DIN terminal (D)
M8 connector (W)
G, H, L, M, W D
Coil rated DC 24, 12, 6, 5, 3 24, 12
voltage (V) AC 50 60 Hz 100, 110 200, 220
Allowable voltage fluctuation (%) ±10% of rated voltage ∗
0.35 [With indicator light: 0.4
Power Standard
(DIN terminal with indicator light: 0.45)]
consumption DC
(W) With power
saving circuit 0.1 (With indicator light only)

100 V - 0.78 (With indicator light: 0.87)

110 V - 0.86 (With indicator light: 0.97)


Apparent [115 V] - [0.94 (With indicator light: 1.07)]
power AC
(VA) ∗ 200 V - 1.15 (With indicator light: 1.30)

220 V - 1.27 (With indicator light: 1.46)


[230 V] - [1.39 (With indicator light: 1.60)]

Diode (Varistor is for DIN terminal


Surge voltage suppressor
and non-polar)
Indicator light LED (AC of DIN connector is neon light.)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC
and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of
rated voltage.
∗ S, Z and T type (with power saving circuit) should be used within the
following allowable voltage fluctuation range due to a voltage drop
caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
12 VDC: –4% to +10%
T type: 24 VDC: –8% to +10%
12 VDC: –6% to +10%

62
Type 60 Body Ported
Weight

Series SY3000 Series SY7000


Port size Weight (g) Port size Weight (g)
M8
Valve model Type of actuation Gro- L/M plug M8 Valve model Type of actuation Gro- L/M plug DIN
A, B A, B Conne-
mmet connector Connector mmet connector terminal
ctor

2 Single 49 51 55 2 Single 103 105 126 109


position Double 70 73 81 position Double 125 128 170 136
SY3 60- -M5 Closed center M5 SY7 60- -02 Closed center 1/4
3 Exhaust center 3 Exhaust center
73 76 84 133 136 178 144
position position
Pressure center Pressure center
2 Single 62 61 65 2 Single 138 139 160 143
position Double C4 80 83 91 position Double C8 160 163 205 171
SY3 60- -C4
3
Closed center
Exhaust center
( One-touch
fitting for ø4 ) 82 86 94
SY7 60- -C8
3
Closed center
Exhaust center
( One-touch
fitting for ø8 ) 168 171 213 179
position position
Pressure center Pressure center
2 Single 55 57 61 2 Single 123 125 146 129
position Double 76 79 87 position Double C10 145 149 191 157
C6

( ) ( )
SY3 60- -C6 Closed center One-touch SY7 60- -C10 Closed center One-touch
3 Exhaust center fitting for ø6 78 82 90 3 Exhaust center fitting for ø10 153 157 199 165
position position
Pressure center Pressure center
Note) [ ]: denotes normal position.

Series SY5000
Port size Weight (g)
M8
Valve model Type of actuation Gro- L/M plug DIN
A, B Conne-
mmet connector terminal
ctor

2 Single 67 69 90 71
position Double 91 94 136 102
SY5 60- -01 Closed center 1/8
3
position Exhaust center 97 100 142 108
Pressure center
2 Single 91 93 114 97
position Double C4 113 116 158 124
SY5 60- -C4
3
Closed center
Exhaust center
( One-touch
fitting for ø4 ) 119 122 164 130
position
Pressure center
2 Single 86 88 109 92
position Double C6 108 111 153 119
SY5 60- -C6
3
Closed center
Exhaust center
( One-touch
fitting for ø6 ) 114 117 159 125
position
Pressure center
2 Single 78 80 101 84
position Double 100 103 145 111
C8
SY5 60- -C8
3
Closed center
position Exhaust center
(
One-touch
fitting for ø8 ) 106 109 151 117
Pressure center

63
SY3000/5000/7000 Body Ported Type 60
How to Order Connector Assembly
How to Order Pilot Valve Assembly for L/M Plug Connector

V111 5 G For DC: SY100 30 4A


Coil specifications Light/surge voltage suppressor Without lead wire: SY100 30 A
Nil Standard Nil Without light/surge voltage suppressor Only connector and sockets (x 2 pcs.)
With power saving circuit S With surge voltage suppressor Lead wire length
T (24 VDC, 12 VDC only) Z With light/surge voltage suppressor
Nil 300 mm
R With surge voltage suppressor (Non-polar type)
∗ Power saving circuit 6 600 mm
is not available in U With light/surge voltage suppressor (Non-polar type)
10 1000 mm
the case of D, DO ∗ Power saving circuit is only available in the "Z" type. 15 1500 mm
or W type.
20 2000 mm
25 2500 mm
Rated voltage 30 3000 mm
5 24 VDC Electrical entry 50 5000 mm
6 12 VDC
G Grommet, 300 mm lead wire
V 6 VDC
H Grommet, 600 mm lead wire
S 5 VDC
L With lead wire
R 3 VDC L plug
LN connector Without lead wire
LO Without connector
M With lead wire
M plug
MN connector Without lead wire
MO Without connector
WO M8 Without connector cable
W connector With connector cable Note 1)
∗ For connector cable of M8 connector,
refer to back page 12.
Note 1) Enter the cable length symbols in
How to Order M8 Connector Cable
. Please be sure to fill in the blank
referring to back page 13.
V100 49 1
 DIN terminal type Cable length

V115 5 D
1 300 mm
2 500 mm
3 1000 mm
Rated voltage Light/surge voltage suppressor 4 2000 mm
5 24 VDC Nil Without light/surge voltage suppressor 7 5000 mm
6 12 VDC S With surge voltage suppressor (Non-polar type) ∗ For details, refer to
1 100 VAC 50 60 Hz Z With light/surge voltage suppressor (Non-polar type) back page 5.
2 200 VAC 50 60 Hz ∗ DOZ is not available.
110 VAC 50 60 Hz ∗ For AC voltage valves there is no “S” option.
3 It is already built-in to the rectifier circuit.
[115 VAC 50 60 Hz]
220 VAC 50 60 Hz
4
[230 VAC 50 60 Hz] Electrical entry
D DIN With connector
∗ DC specifications of
Type D and DO is DO terminal Without connector
only available with Note) Do not replace V111 (G, H, L, M)
12 and 24 VDC. to V115 (DIN terminal) and vice
versa when replacing pilot valve
assembly only.

64
Type 60 Body Ported
How to Order Port Block Assembly How to Change Port Block Assembly
Connecting port size of A and B can be changed by replacing port
block assembly mounted on body. When changing block assembly,
SY 3 000 6A C4 correct screw torque must be achieved to avoid trouble; e.g. air
Series leakage.
3 SY3000 With the one-touch fitting port block assembly, it is only necessary to
5 SY5000 change the fitting and not the whole block. Refer to following part
7 SY7000 numbers.

A, B port size One-touch fitting (Metric size)


Thread piping Port size Fitting assembly part no. Applicable series
Symbol Port size Applicable series One-touch fitting for ø4 VVQ1000-50A-C4
SY3000
M5 M5 SY3000 One-touch fitting for ø6 VVQ1000-50A-C6
01 1/ 8
SY5000 One-touch fitting for ø4 VVQ1000-51A-C4
02 1/ 4
SY7000 One-touch fitting for ø6 VVQ1000-51A-C6 SY5000
One-touch fitting for ø8 VVQ1000-51A-C8
One-touch fitting (Metric size) One-touch fitting for ø8 VVQ2000-51A-C8
SY7000
Symbol Port size Applicable series
One-touch fitting for ø10 VVQ2000-51A-C10
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
SY3000 One-touch fitting (Inch size)
C4 One-touch fitting for ø4 Port size Fitting assembly part no. Applicable series
C6 One-touch fitting for ø6 SY5000 One-touch fitting for ø5/32" VVQ1000-50A-N3
SY3000
C8 One-touch fitting for ø8 One-touch fitting for ø1/4" VVQ1000-50A-N7
C8 One-touch fitting for ø8 One-touch fitting for ø5/32" VVQ1000-51A-N3
SY7000 One-touch fitting for ø1/4" VVQ1000-51A-N7 SY5000
C10 One-touch fitting for ø10
One-touch fitting for ø5/16" VVQ1000-51A-N9
One-touch fitting (Inch size) One-touch fitting for ø1/4" VVQ2000-51A-N9
SY7000
Port size One-touch fitting for ø3/8" VVQ2000-51A-N11
Symbol Applicable series
N3 One-touch fitting for ø5/32"
SY3000
N7 One-touch fitting for ø1/4" Port block assembly
N3 One-touch fitting for ø5/32" (Cassette type)
N7 One-touch fitting for ø1/4" SY5000 Port block assembly
N9 One-touch fitting for ø5/16" (Thread type)
N9 One-touch fitting for ø5/16"
SY7000
N11 One-touch fitting for ø3/8"
Mounting screw

Fitting assembly

Caution
Torque for mounting screws
SY3000(M2): 0.12 N·m
SY5000, 7000 (M3): 0.6 N·m
∗ Refer to “How to Change Port Block
Assembly” for part numbers.

65
SY3000/5000/7000 Body Ported Type 60
Manifold Option
 Individual SUP block assembly  Individual EXH block assembly
(P port) R port
Plug
P

Blocking disk

R
Blocking disk
P

Ds

P
ide
Ds
ide
One-touch fitting (Metric size) One-touch fitting (Metric size)
Us Port size Assembly part no. Applicable series Port size Assembly part no. Applicable series
ide
One-touch fitting for ø6 SY3000-54-2C-Q Us One-touch fitting for ø8 SY3000-55-1B-Q SY3000
SY3000 ide
One-touch fitting for ø8 SY3000-54-1C-Q One-touch fitting for ø10 SY5000-55-1B-Q SY5000
One-touch fitting for ø10 SY5000-54-1C-Q SY5000 One-touch fitting for ø12 SY7000-55-1B-Q SY7000
One-touch fitting for ø12 SY7000-54-1C-Q SY7000
One-touch fitting (Inch size)
One-touch fitting (Inch size) Port size Assembly part no. Applicable series
Port size Assembly part no. Applicable series One-touch fitting for ø5/16" SY3000-55-2B-Q SY3000
One-touch fitting for ø5/16" SY3000-54-3C-Q SY3000 One-touch fitting for ø3/8" SY5000-55-2B-Q SY5000
One-touch fitting for ø3/8" SY5000-54-2C-Q SY5000 One-touch fitting for ø3/8" SY7000-55-3B-Q SY7000
One-touch fitting for ø3/8" SY7000-54-3C-Q SY7000

[When supplying the manifold with 2 different supply pressures.] [When 2 different EXH passages are required.]
Specify arrangement of individual SUP block assembly on the manifold specification Specify arrangement of individual EXH block assembly on the manifold specification
sheet. (When using SS5Y-60-D, blocking disk is assembled on D side.) sheet. (When using SS5Y-60-D, blocking disk is assembled on D side.)
<Manifold model no.: SS5Y 35 -60- U
D> <Manifold model no.: SS5Y 35 -60- U
D>
Individual SUP block assembly Individual EXH block assembly

U side D side U side D side

B B B B B B B B
A A A A A A A A

RP P RP R

[When a different supply pressure is required for only a middle valve.] [When a separate exhaust passage is needed on only a middle valve.]
Specify arrangement of individual SUP block assembly and SUP Specify arrangement of individual EXH block assembly and EXH blocking
blocking disk on the manifold specification sheet. disk on the manifold specification sheet.
(Applicable manifold model no.: SS5Y-60-B) (Applicable manifold model no.: SS5Y-60-B)
L Individual SUP block assembly Individual EXH block assembly
SUP blocking disk EXH blocking disk

U side D side U side D side

B B B B B B B B
A A A A A A A A

RP P PR RP R PR

66
Type 60 Body Ported
Manifold Option

 SUP blocking disk  Plug (white)


By installing a SUP blocking disk in the pressure supply passage of a These are inserted in unused cylinder ports and SUP, EXH ports.
manifold valve, it is possible to supply two or more different high and low Purchasing order is available in units of 10 pieces.

ød
pressures to one manifold. (This is the same block disk used with the
individual SUP block assembly.)

øD
Series No. A
SY3000 SY3000-52-6A L
Dimensions
SY5000 SY5000-52-4A
Applicable fittings size ød Model A L D
SY7000 SY7000-70-2A 4 KQ2P-04 16 32 6
 EXH blocking disk 6 KQ2P-06 18 35 8
By installing an EXH blocking disk in the exhaust passage of a manifold 8 KQ2P-08 20.5 39 10
valve, it is possible to divide the valve’s exhaust so that it does not affect 10 KQ2P-10 22 43 12
another valve. (Two blocking disks are needed to separate both EXH 12 KQ2P-12 24 45.5 14
passages. It is the same block disk that is used in the individual EXH 5/32" KQ2P-03 16 32 6
block assembly.) 1/4" KQ2P-07 18 35 8.5
Series No.
5/16" KQ2P-09 20.5 39 10
SY3000 SY3000-52-6A 3/8" KQ2P-11 22 43 11.5
SY5000 SY5000-52-4A
 DIN Rail Dimensions/Weight for SY3000/5000
SY7000 SY7000-70-2A
VZ1000-11-1-
 Label for block disk
Refer to the L dimension tables
The labels shown below are used on manifold stations containing
∗ Enter a number from the DIN rail dimension table below in them.
SUP/EXH blocking disk(s) to show their location. (3 pcs. each)
L (7.5)
VZ3000-123-1A 8
Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk

P P P P P

(35)
(25)
5.5

R R R R R
0 1 2 3 4 5 6 7 8 9
∗ When a block disk is concurrently ordered by specifying on the manifold specification L2 [Rail mounting pitch 12.5]
sheet, etc., a label will be stuck on the position where block disk is mounted.
No.
L dimension 10
98 110.5
11 123
12 135.5
13 148
14 160.5
15 173
16 185.5
17 198
18 210.5
19
Weight (g) 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9

No.
L dimension 223
20 235.5
21 248
22 260.5
23 273
24 285.5
25 298
26 310.5
27 323
28 335.5
29
R Weight (g) 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1 60.4
A

No.
L dimension 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5
P Weight (g) 62.6 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9
B

P
R R

 DIN Rail Dimensions/Weight for SY7000


SY3000 SY5000 VZ1000-11-4-
SY7000
P Refer to the L dimension tables
R R ∗ Enter a number from the DIN rail dimension table below in them.
P
R R L (10)
End plate side 8
End plate side
(24)
(35)
5.5

 Silencer with One-touch fitting


0 1 2 3 4 5 6 7 8 9
The silencer plugs directly into the One-touch fittings of the manifold. L2 [Rail mounting pitch 12.5]

C No.
B L dimension 10
98 110.5
11 123
12 135.5
13 148
14 160.5
15 173
16 185.5
17 198
18 210.5
19
Weight (g) 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3
A

No.
L dimension 223
20 235.5
21 248
22 260.5
23 273
24 285.5
25 298
26 310.5
27 323
28 335.5
29
Weight (g) 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7 84.9
Series Model Effective area A B C
SY3000 (for ø8) AN203-KM8 14 mm2 ø16 26 51 No.
AN200-KM10 26 mm2 ø22 54 80.8 L dimension 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5
SY5000 (for ø10)
AN300-KM10 30 mm2 ø25 70 97 Weight (g) 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5
SY7000 (for ø12) AN300-KM12 41 mm2 ø25 70 98
Note) For DIN rail mounting, refer to page 226.
67
SY3000/5000/7000 Body Ported Type 60
Construction

Series SY

JIS Symbol 2 position single


2 position single (A) (B)
(A) (B) 4 2
4 2 y r w t u q e

5 1 3
(EA) (P)(EB)

5(EA) 1(P) 3(EB)


i
JIS Symbol 2 position double
2 position double (A) (B)
4 2
(A) (B)
4 2 y w t u q r

5 1 3
(EA) (P)(EB)

5(EA) 1(P) 3(EB)


i
JIS Symbol 3 position closed center / exhaust center / pressure center
3 position closed center (A) (B)
(A) (B)
4 2
4 2
y w t u q r
5 1 3
(EA) (P)(EB)

3 position exhaust center


(A) (B)
4 2

5 1 3
(EA) (P)(EB)

3 position pressure center


(A) (B)
4 2

5 1 3
(EA) (P)(EB)
5(EA) 1(P) 3(EB)
i
(This figure shows a closed center type.)

Component Parts Replacement Parts


No. Description Material Note No. Description No.
Aluminum die-casted 6 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 64.
1 7
Body
( SY3000:
Zinc die-casted ) White Port block assembly
Bottom cover
Refer to “How to Order Port Block Assembly” on page 65.
SY3000-41-2A (with screw, gasket)
8
2 Adapter plate Resin White assembly Note) SY5000-41-2A (with screw, gasket)
3 End plate Resin White Note) There is no bottom cover assembly available for SY7000.
4 Piston Resin —
5 Spool valve assembly Aluminum/NBR —

68
Type 60 Body Ported
Dimensions
SS5Y3-60- Stations U-Q
One-touch fitting (Station n) (Station 1)
Stations 2 stations 3 4 5 6 7 8 9 10 stations
(P, R port)
L1 98 110.5 123 135.5 135.5 148 160.5 173 185.5 Applicable tubing O.D.: ø8, ø5/16"
(Light/surge voltage suppressor)

(3.2)
L2 87.5 100 112.5 125 125 137.5 150 162.5 175
L3 69.5 80 90.5 101 111.5 122 132.5 143 153.5

(3)
L4 14 15 16 17 12 13 14 15 16

C6:43.3
N7:47.1
- + - + - + - + - + - +

38.2
33.4

7.5

28.2
22.8
20.7
U side D side
One-touch fitting
(A, B port) L3 (L4)
Applicable tubing O.D.: ø4, ø5/32" Manual
ø6, ø1/4" override

M5 DIN rail
(A, B port) 8

22.5 1
30.7

4.1
22.2

5.5
P

35
97.3
88.8

4.7
22.2

10.2
26

44.4
(Lead wire length)

(3)
Approx. 300

DIN rail
33.2 holding screw
(Pitch)
(M5 port) 24.3 13.5 P = 10.5 21.3
L2 5
(Rail mounting hole pitch: 12.5)
L1

SS5Y3-60- Stations D-Q


(Station n) (Station 1)
One-touch fitting
Stations 2 stations 3 4 5 6 7 8 9 10 stations (P, R port)
Applicable tubing O.D.: ø8, ø5/16"
(3.2)

L1 98 110.5 123 135.5 135.5 148 160.5 173 185.5 (Light/surge voltage suppressor)
L2 87.5 100 112.5 125 125 137.5 150 162.5 175
(3)

L3 69.5 80 90.5 101 111.5 122 132.5 143 153.5


C6:43.3
N7:47.1

L4 14 15 16 17 12 13 14 15 16 - + - + - + - + - + - +
38.2

33.4
28.2
7.5
22.8

20.7

L3 (L4)
U side D side
Manual override
M5
(A, B port) 8
4.1

22.5 1
30.7
22.2

P
5.5
B

B
97.3
88.8

4.7
35
22.2
10.2

26

R
A

A
44.4
(Lead wire length)
Approx. 300

(3)

DIN rail
33.2 (Pitch)
P = 10.5 13.5 24.3 DIN rail holding screw
(M5 port)
L2 5
One-touch fitting (Rail mounting hole pitch: 12.5)
(A, B port) L1
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"

69
SY3000/5000/7000 Body Ported Type 23

SS5Y3-60- Stations B-Q

Stations 2 stations 3 4 5 6 7 8 9 10 stations


L1 110.5 123 135.5 148 160.5 173 173 185.5 198
L2 100 112.5 125 137.5 150 162.5 162.5 175 187.5
L3 86 96.5 107 117.5 128 138.5 149 159.5 170
L4 12 13 14 15 16 17 12 13 14

Stations 11 stations 12 13 14 15 16 17 18 19 20 stations (Station n) (Station 1)


L1 210.5 223 235.5 235.5 248 260.5 273 285.5 298 310.5 One-touch fitting
L2 200 212.5 225 225 237.5 250 262.5 275 287.5 300 (P, R port)
(Light/surge voltage suppressor) Applicable tubing O.D.: ø8, ø5/16"

(3.2)
L3 180.5 191 201.5 212 222.5 233 243.5 254 264.5 275
L4 15 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5

(3)
C6:43.3
N7:47.1
- + - + - + - + - + - +

38.2

33.4
28.2
7.5
22.8

20.7
Manual override
L3 (L4)
U side D side

M5
(A, B port) 8

4.1

1
30.7

22.5
22.2 22.2

P P

5.5
B

B
10.2

35
97.3
88.8

4.7

26
R R
A

A
44.4
(Lead wire length)

(3)
Approx. 300

DIN rail
33.2 (Pitch) DIN rail
P = 10.5 13.5 24.3
(M5 port) holding screw
L2 5
(Rail mounting hole pitch: 12.5)
One-touch fitting
L1
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"

L plug connector (L) M plug connector (M) M8 connector (WO)


38.2
22.8
(Lead wire length)
Approx. 300

(Lead wire length)


Approx. 300 49.3 M8 x 1
115.3

100.5
117.1

97.5

106.8
108.6

89

92
44.5

46
53.4
54.3

25.2
42.7

Note) Refer to back page 12 for


dimensions of connector types.

70
Type 60 Body Ported
Dimensions (mm)
SS5Y5-60- Stations U-Q

Stations 2 stations 3 4 5 6 7 8 9 10 stations


L1 123 135.5 148 160.5 185.5 198 210.5 235.5 248 One-touch fitting (Station n) (Station 1)
L2 112.5 125 137.5 150 175 187.5 200 225 237.5 (P, R port)

(4.9)
Applicable tubing O.D.: ø10, ø3/8" (Light/surge voltage suppressor)
L3 88 104 120 136 152 168 184 200 216

(5.5)
L4 17.5 15.5 14 12 16.5 15 13 17.5 16

51.9
R

43.8
- + - + - + - + - + - +

34.5

7.5

24.2
19.1
U side D side
(Lead wire length)

One-touch fitting
Approx. 300

(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
Manual override 1/8 ø6, ø1/4"
(A, B port) ø8, ø5/16"
8 Button for
DIN rail release
(DIN: 47.9)

(DIN: 35.3)
46.6

16.2
14.5

34.9
B

B
B

B
2.6

20.7 25.9
34
119.8

5.5
107.2

5.8

(DIN: 30.1)
35
5.5

28.8
4.7
30

R A

A
51

(5.5)

DIN rail
DIN rail
39.6 (Pitch) holding screw
28 20
P = 16 24
44 L3 (L4)
(1/8 port) L2 5
(Rail mounting hole pitch: 12.5)
L1
SS5Y5-60- Stations D-Q

Stations 2 stations 3 4 5 6 7 8 9 10 stations (Station n) (Station 1)


L1 123 135.5 148 160.5 185.5 198 210.5 235.5 248 One-touch fitting
(4.9)

L2 112.5 125 137.5 150 175 187.5 200 225 237.5 (P, R port)
(Light/surge voltage suppressor)

(5.5)
Applicable tubing O.D.: ø10, ø3/8"
L3 88 104 120 136 152 168 184 200 216
L4 17.5 15.5 14 12 16.5 15 13 17.5 16
51.9

R
43.8
- + - + - + - + - + - +
34.5
7.5
24.2

19.1

U side D side
(Lead wire length)
Approx. 300

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
Manual override
ø6, ø1/4"
ø8, ø5/16"
1/8
(A, B port) 8 Button for
(DIN: 30.1) (DIN: 35.3)

DIN rail release


(DIN: 47.9)
46.6

16.2
14.5

34.9
B

B
B

B
2.6

20.7 25.9
34
119.8

P
107.2

5.8
28.8

35
5.5

5.5
4.7

30

R
A

A
51

(5.5)

DIN rail
39.6 (Pitch) DIN rail
P = 16 20 28 holding screw
44 (L4)
L3
(1/8 port)
L2 5
(Rail mounting hole pitch: 12.5)
L1

71
SY3000/5000/7000 Body Ported Type 60

SS5Y5-60- Stations B-Q

Stations 2 stations 3 4 5 6 7 8 stations


L1 135.5 160.5 173 185.5 210.5 223 235.5
L2 125 150 162.5 175 200 212.5 225
L3 112 128 144 160 176 192 208
L4 11.5 16 14.5 12.5 17.5 15.5 13.5
(Station n) (Station 1)
One-touch fitting
Stations 9 stations 10 11 12 13 14 15 stations
(P, R port)
L1 248 273 285.5 298 323 335.5 348 Applicable tubing O.D.: ø10, ø3/8"

(4.9)
(Light/surge voltage suppressor)
(5.5)
L2 237.5 262.5 275 287.5 312.5 325 337.5
L3 224 240 256 272 288 304 320
L4 12 16.5 14.5 13 17.5 15.5 14

51.9
R R
43.8

Stations 16 stations 17 18 19 20 stations - + - + - + - + - + - +


34.5

24.2
L1 360.5 385.5 398 410.5 435.5
19.1

L2 350 375 387.5 400 425


7.5

L3 336 352 368 384 400


U side D side
(Lead wire length)

L4 12 16.5 15 13 17.5
Approx. 300

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
Manual override ø6, ø1/4"
1/8 ø8, ø5/16"
8 Button for
(A, B port)
DIN rail release
(DIN: 47.9)

(DIN: 35.3)
46.6

16.2
14.5

34.9
B

B
B

B
2.6

20.7 25.9
34
119.8

P P
107.2

(DIN: 30.1)
5.8

35
5.5

28.8
5.5
4.7
30

R R
A

A
51

(5.5)

DIN rail
DIN rail
39.6 (Pitch) holding screw
P = 16 20 28
44
(1/8 port) L3 (L4)
L2 5
(Rail mounting hole pitch: 12.5)
L1

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
39.6
(Lead wire length)

24.2
Approx. 300

(Lead wire length)


Approx. 300 50.6
139.6

157.8

159.6

137.8
120

123
107.4

145.2

110.4

125.2
127

147
60.9 [63.1]

51.1

52.6

60
70.9
70

26.6
M8 x 1 44.1
53.6
MAX.10

Pg7
64.9
72.4 Note) Refer to back page 12 for
Applicable cable O.D. dimensions of connector types.
ø3.5 to ø7
72
Type 60 Body Ported
Dimensions
SS5Y7-60- Stations U-Q
(Station n) (Station 1)

(5.5)
(Light/surge voltage suppressor)
Stations 2 stations 3 4 5 6 7 8 9 10 stations

(5.4)
L1 135.5 148 173 185.5 210.5 223 248 260.5 285.5
L2 125 137.5 162.5 175 200 212.5 237.5 250 275

58.6
L3 103 122 141 160 179 198 217 236 255

49.1
- + - + - + - + - + - +

L4

39
16 13 16 12.5 15.5 12.5 15.5 12 15

27.1
25.4
3/5 R

10
One-touch fitting
[1(P), 3/5(R) port]
Applicable tubing O.D.: ø12, ø3/8"
(Lead wire length)

U side D side
Approx. 300

One-touch fitting
[4(A), 2(B) port]
Manual override Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8" DIN rail holding screw
8 DIN rail
(DIN: 52.8)

(DIN: 39.8)
51.5

39.4
B

B
2

2
38.5

19

28
5.5
134.4

1P

35
121.4

(DIN: 39.8)
28
20
38.1

38.5
60.7

A
4

4
(5.4)

1/4
[4 (A), 2 (B) port]
42.5 (Pitch)
32.5 22 L3 P = 19 29.5 (L4)
51
(1/4 port) L2 5
(Rail mounting hole pitch: 12.5)
L1
SS5Y7-60- Stations D-Q
(Station n) (Station 1)
(5.5)

(5.4)
Stations 2 stations 3 4 5 6 7 8 9 10 stations (Light/surge voltage suppressor)
L1 135.5 148 173 185.5 210.5 223 248 260.5 285.5
L2 125 137.5 162.5 175 200 212.5 237.5 250 275
58.6

L3 103 122 141 160 179 198 217 236 255


49.1
- + - + - + - + - + - +
39

L4 16 13 16 12.5 15.5 12.5 15.5 12 15


27.1

25.4

3/5 R
10

One-touch fitting
[1(P), 3/5(R) port]
Applicable tubing O.D.: ø12, ø3/8"
(Lead wire length)

U side D side
Approx. 300

One-touch fitting
[4(A), 2(B) port]
Manual override Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"
1/4 DIN rail holding screw
[4 (A), 2 (B) port] 8 DIN rail
(DIN: 39.8)
(DIN: 52.8)
51.5

39.4
B

B
2

2
38.5

19

28
5.5
134.4

1P

35
121.4

8
28
20

38.1
(DIN: 39.8)
38.5
60.7

A
4

(5.4)

42.5 (Pitch)
P = 19 22 32.5
51 L3 (L4)
(1/4 port)
L2 5
(Rail mounting hole pitch: 12.5)
L1

73
SY3000/5000/7000 Body Ported Type 60

SS5Y7-60- Stations B-Q

Stations 2 stations 3 4 5 6 7 8 stations


L1 160.5 173 198 210.5 235.5 248 273
L2 150 162.5 187.5 200 225 237.5 262.5
L3 128 147 166 185 204 223 242
L4 16 13 16 12.5 15.5 12.5 15.5
(Station n) (Station 1)
Stations 9 stations 10 11 12 13 14 15 stations

(5.5)
L1 285.5 310.5 323 348 360.5 385.5 410.5
(Light/surge voltage suppressor)
(5.4)
L2 275 300 312.5 337.5 350 375 400
L3 261 280 299 318 337 356 375
L4 12 15 12 15 11.5 14.5 17.5

58.6
49.1

- + - + - + - + - + - +

Stations 16 stations 17 18 19 20 stations


39

27.1
25.4

3/5 R 3/5 R

L1 423 448 460.5 485.5 498


10

L2 412.5 437.5 450 475 487.5 One-touch fitting[


L3 394 413 432 451 470 1(P), 3/5(R) port]
(Lead wire length)

L4 14.5 17.5 14 17 14 U side Applicable tubing O.D.: ø12, ø3/8" D side


Approx. 300

One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D.: ø8, ø5/16"
Manual override ø10, ø3/8"
1/4 DIN rail holding screw
[4 (A), 2 (B) port] 8 DIN rail
(DIN: 39.8)
(DIN: 52.8)
51.5

39.4
B

B
2

2
38.5

5.5
19

28
134.4

1P

1P

35
121.4

8
(DIN: 39.8)

28
38.1
20
38.5
60.7

A
4

(5.4)
42.5 (Pitch)
51 P = 19 22 32.5
L3 (L4)
(1/4 port)
L2 5
(Rail mounting hole pitch: 12.5)
L1

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
42.5
(Lead wire length)

27.1
Approx. 300

(Lead wire length)


Approx. 300 53.6 M8 x 1
154.2

134.6

172.4

174.2

152.4

137.6
141.2

121.6

159.4

161.2

124.6
132
60.8

62.3
70.6

69.7
79.7

80.6

29.5
47
58.2
Pg7
MAX.10

69.5
77
Note) Refer to back page 12 for
Applicable cable O.D. dimensions of connector types.
ø3.5 to ø7
74
Type 60 Body Ported
DIN Rail Manifold Exploded View
SY3000
Type 60

e
D side w

q
R

t y
w

R
r
P

a DIN rail
holding screw

U side
Replacement Parts
No. Description No. Note
 at the end of part number denotes A. B port size: M5, C4, C6, N3, N7.
1 Valve SY360---Q Includes bushing assembly (SY3000-52-5A) 3 pcs.

P, R port (1: One-touch fitting for ø8, 2: One-touch fitting for ø5/16")
2 SUP/EXH block assembly SY3000-55- 1 A-Q Includes bushing assembly (SY3000-52-5A) 3 pcs.
2

3 End block assembly


SY3000-56-1A-Q For D side (Bushing assembly: Not available for SY3000-52-5A)
4 End block assembly SY3000-56-1B-Q For U side (Bushing assembly: Not available for SY3000-52-5A)
5 Bushing assembly SY3000-52-5A
6 DIN rail VZ1000-11-1- Refer to page 67.

75
SY3000/5000/7000 Body Ported Type 60

SY5000
Type 60 e

D side
w
R

PUS
P q
H

t y
w a DIN rail
R holding screw

P r

PUS
H
U side
Replacement Parts
No. Description No. Note
 at the end of part number denotes A. B port size: 01, C4, C6, C8, N3, N7, N9.
1 Valve SY560---Q Includes bushing assembly (SY5000-52-3A) 3 pcs.

P, R port (1: One-touch fitting for ø10, 2: One-touch fitting for ø3/8")
2 SUP/EXH block assembly SY5000-55- 1 A-Q Includes bushing assembly (SY5000-52-3A) 3 pcs.
2

3 End block assembly


SY5000-56-1A-Q For D side (Bushing assembly: Not available for SY5000-52-3A)
4 End block assembly SY5000-56-1B-Q For U side (Bushing assembly: Not available for SY5000-52-3A)
5 Bushing assembly SY5000-52-3A
6 DIN rail VZ1000-11-1- Refer to page 67.

How to Add Additional Valves to the DIN Rail Valves can be added at any station on the rail.
Fig. 1 Manifold mounting procedure Fig. 2 Manifold dismounting procedure
1 Loosen the manifold base clamping screw a.

Remove upwards
2 Separate the valves at the point where more valves are to be added. from side B. Slide it onto side B.
q
w
3 Mount the additional valves on the DIN rail as shown in Fig. 1 ide
As
ide
As
End plate
4 Connect them together while pressing the block assemblies toward each
others, and tighten the holding screw a to fix them to the DIN rail.
ide
Bs Hook this part of side B on the DIN
Caution rail and press down in the direction ide
of the arrow. Bs
Tightening torque
While pressing the bottom of the valve onto the lip of the
SY3000: 1 N·m DIN rail, pull side B upwards and dismount from the rail.
SY5000: 1.4 N·m
(While lightly holding the blocks after fixing an end block on one side,
tighten the other end block for better sealing after no gap between
valves is confirmed.)
• Bushing assembly must be seated properly to each Caution When clamping screw a of the end block is not sufficiently
tightened during reassembly, air leakage may result. Before
valve block in order to prevent air leaks from occurring.
supplying air, check that there are no gaps between valves
• Refer to the fig. 2 when dismounting the valve from the and that the end block is firmly secured to the DIN rain in order
DIN rail. to ensure air supply without leakage.
76
Type 60 Body Ported
DIN Rail Manifold Exploded View
SY7000
Type 60 e
D side
w

w
t a DIN rail
holding screw

Replacement Parts U side


No. Description No. Note
 at the end of part number denotes A. B port size: 02, C8, C10, N9, N11.
1 Valve SY760---Q Includes bushing assembly (SY7000-70-1A) 3 pcs.

2 SUP/EXH block assembly SY7000-75- 1A-Q


3

3 End block assembly SY7000-56-1A-Q In common for D side and U side (Bushing assembly: Not available for SY7000-70-1A.)
4 Bushing assembly SY7000-70-1A
5 DIN rail VZ1000-11-4- Refer to page 67.

How to Add Additional Valves to the DIN Rail Valves can be added at any station on the rail.
1 Loosen the rail holding screw a at both of 2 locations which Fig. 1 Manifold mounting procedure Fig. 2 Manifold dismounting procedure
holds the manifold base either in the U side or D side.
Remove upwards
When removing the end block assembly from the DIN rail, loosen the
from side A.
holding screws for DIN rail at first, then slide it to the edge of the rail.
2 Separate the valves at the point where more valves are to Slide it onto side A.
w
be added.

3 Mount the additional valves on the DIN rail as shown in Fig. 1. q


ide ide
As As
4 Connect them together while pressing the block assemblies toward each
others, and tighten the 2 holding screws a for DIN rail alternately (2 to
3 times) with the prescribed torque (1.4 N·m) to fix them to the DIN rail.
ide ide
Caution Bs Bs While pressing the bottom of the
While pressing the B side stopper valve onto the lip of the DIN rail,
Tightening torque pull side A upwards and dismount
onto the DIN rail, insert into the rail.
SY7000: 1.4 N·m from the rail.
(While lightly holding the blocks after fixing an end block on one side,
tighten the other end block for better sealing after no gap between
valves is confirmed.)
Caution When clamping screw a of the end block is not sufficiently
tightened during reassembly, air leakage may result. Before
• Bushing assembly must be seated properly to each supplying air, check that there are no gaps between valves
valve block in order to prevent air leaks from occurring. and that the end block is firmly secured to the DIN rain in
• Refer to the fig. 2 when dismounting the valve from the order to ensure air supply without leakage.
DIN rail.

77
78
5 Port Solenoid Valve
Type 41 Series SY3000/5000/7000
Base Mounted
Type 42 Bar Stock Type/Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly (Example)

Type 41/Compact style


Example
SS5Y 5 41 05 C8 -Q Single solenoid (24 VDC)
SY3140-5G-Q (2 set)

Manifold series Stations Thread type


Double solenoid (24 VDC)
3 SY3000 02 2 stations - Rc SY3240-5G-Q (2 set) 1
5 SY5000 F G
...

...

2
20 20 stations N NPT Blanking plate assembly 3

∗ This also includes the


T NPTF SY3000-26-9A-Q (1 set)
Sta
∗ Except for M5 tio
number of blanking ns
plate assemblies.

A, B port size
Thread piping -+
Symbol Port size Applicable series -+

M5 M5 SY3000
EA
01 18 SY5000
P
EB
One-touch fitting (Metric size) One-touch fitting (Inch size) A
Symbol Port size Applicable series Symbol Port size Applicable series
B
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
Cylinder port size Manifold base (5 stations)
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000 C6: With one-touch fitting for ø6 SS5Y3-41-05-C6-Q
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"

SS5Y3-41-05-C6-Q 1 set (Type 41, 5 stations manifold base part no.)


Type 42/External pilot capable ∗ SY3240-5G-Q 2 sets (Double solenoid part no.)
∗ SY3140-5G-Q 2 sets (Single solenoid part no.)
SS5Y 5 42 05 C8 -Q ∗ SY3000-26-9A-Q 1 set (Blanking plate assembly part no)

The asterisk denotes the symbol for assembly.


Manifold series Stations Thread type Prefix it to the part nos. of the solenoid valve, etc.
3 SY3000 02 2 stations - Rc Add the valve and option part number under the manifold base part
5 SY5000 F G number. In the case of complex arrangement, specify them on the manifold
...

...

7 SY7000 20 20 stations N NPT specification sheet.


T NPTF

A, B port size
Thread piping
Symbol Port size Applicable series
01 18 SY3000
02 14 SY5000
02 14 SY7000

One-touch fitting (Metric size) One-touch fitting (Inch size)


Symbol Port size Applicable series Symbol Port size Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 4"
1
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
C10 One-touch fitting for ø10 SY7000 N11 One-touch fitting for ø 8" SY7000
3

79
SY3000/5000/7000 Base Mounted Type 41 42
Type

How to Order Valve

SY 5 2 40 5 L -Q

Series Manual override


3 SY3000 - Non-locking push type
5 SY5000 D Push-turn locking slotted type
7 SY7000 E Push-turn locking lever type

Type of actuation
1 2 position single
2 2 position double Light/surge voltage suppressor
3 3 position closed center
Electrical entry for G, H, L, M, W
4 3 position exhaust center
- Without light/surge voltage suppressor
5 3 position pressure center
S With surge voltage suppressor
Pilot type Z With light/surge voltage suppressor
- Internal pilot R With surge voltage suppressor (Non-polar type)
R External pilot U With light/surge voltage suppressor (Non-polar type)
∗ Power saving circuit is only available in the "Z"
type.
Coil specifications
- Standard
With power saving circuit
T (24 VDC, 12 VDC only)
Electrical entry for D (SY5000/7000 only)
∗ Power saving circuit is not
available in the case of D, - Without light/surge voltage suppressor
DO or W type. S With surge voltage suppressor (Non-polar type)
Z With light/surge voltage suppressor (Non-polar type)
∗ DOZ is not available.
Rated voltage ∗ For AC voltage valves there is no “S” option. It is
For DC already built-in to the rectifier circuit.
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
For AC ( 50 60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of Type D
and DO is only available with
12 and 24 VDC.
∗ AC specification is only
available with D and DO type.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 24, 12, 6, 5, 3 VDC
220 VAC
Grommet L plug connector M plug connector DIN terminal Note2 M8 connector ∗
G: Lead wire length L: With lead wire M: With lead wire D: With connector WO: Without connector
300 mm lead (Length 300 mm) (Length 300 DO: Without cable
H: Lead wire length LN: Without lead wire mm) connector W: With connector
600 mm LO: Without MN: Without lead cable Note 1)
∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available.
For details, refer to page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back page 13.
Note 2) SY5000/7000 only.

80
Type 41 42 Base Mounted
Type

Manifold Specifications

Model SS5Y3-41 SS5Y3-42 SS5Y5-41 SS5Y5-42 SS5Y7-42


Applicable valve SY340 SY540 SY740
Manifold type Single base/B mount
P(SUP)/R(EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations Note 1)
A, B port Location Base
Porting specifications Direction Side
P, EA, EB port 18 14 14
Port M5, 18 18 14
14
size A, B port C4 (One-touch fitting for ø4) C4 (One-touch fitting for ø4) C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6)
C10 (One-touch fitting for ø10)
C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6) C8 (One-touch fitting for ø8) C8 (One-touch fitting for ø8)
Manifold base weight
W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151
W (g) n: Stations
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P
port on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Option” on page 109.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]* C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]*
SS5Y3-41 18 C6 0.75 0.19 0.18 179 0.81 0.23 0.20 197
SS5Y3-42 18 C6 0.75 0.20 0.18 180 0.82 0.20 0.20 196
SS5Y5-41 14 C8 1.8 0.23 0.44 439 1.9 0.16 0.45 445
SS5Y5-42 14 C8 1.9 0.20 0.46 455 1.9 0.12 0.43 436
SS5Y7-42 14 C10 3.0 0.25 0.75 740 3.0 0.12 0.66 688
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

81
SY3000/5000/7000 Base Mounted Type 41
SY3000: SS5Y3-41- Stations -M5, C4,N3
C6,N7 -Q
Grommet (G) With interface regulator (with gauge)

(Station 1) (Station n)
For M5
(Light/surge voltage suppressor)
(Light/surge voltage suppressor)
One-touch fitting
(A, B port)
M5 Applicable tubing O.D. : ø4, ø5/32"
-+ -+ (A, B port) -+ -+
: ø6, ø1/4"
57.5

57.5
42.1

42.1

A A A A
28.5

28.5
6.5
6.5

20.7
20.7

B B B B 72 ø15
10.5 7 (Pitch) 10.5 7 (Pitch)
P = 10.5 P = 10.5
(Lead wire length)
Approx. 300

With plug
13.6

(7)
8.5 Manual
override 4-ø4.5

124.8
(For mounting)

111.3
EA

4-ø4.5
15.5 15.5

72.2
A A A A A
(For mounting)

EA
88.8
16
53.7
P

97.3

50

A A A

16
30.5

53.7
5.6

P
B B B B B
22.5
EB

B B B

22.5
EB
2.9
(3.2)

(29.5)
1/8 (Pitch)
(P, EA, EB port) 14 P = 10.5
4 L2 28.5 (Pitch)
36.5 14 P = 10.5
L1
72.5

L plug connector (L) M plug connector (M) M8 connector (WO)


(Lead wire length)
Approx. 300

57.5
42.1
62
M8 x 1 44.5
Approx. 300 68.6
(Lead wire length)
82.1
EA

EA

81.3

73.8
72.3
108.6

106.8

100.5
115.3
117.1

89
P

92
97.5
EB

EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 38.5 49 59.5 70 80.5 91 101.5 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5
L2 30.5 41 51.5 62 72.5 83 93.5 104 114.5 125 135.5 146 156.5 167 177.5 188 198.5 209 219.5

82
Type 41 Base Mounted
C6, N7
SY5000: SS5Y5-41- Stations -01, C8, N9 -Q
Grommet (G)

For 1 8
(Station 1) (Station n) With interface regulator (with gauge)
ø15

C8, N9: 23.5


(Light/surge voltage suppressor) (Light/surge voltage suppressor)

With plug
C6, N7: 23

(14.5)
-+ -+ -+ -+
61.6

61.6
46.2

A A 46.2 A A 4-ø4.5
(For mounting)
33

33

106.7
23

EA
A A A
B B B B

9 C6, N7: 9

7.5

20
7.5

66.7
(Pitch)

P
1/8 C8, N9: 7.5
15.5 P = 16 C6, N7: 15.5 (Pitch) One-touch fitting
(A, B port) C8, N9: 17 P = 16 (A, B port)

27.7
B B B

EB
Applicable tubing O.D.: ø6, ø1/4"
(Lead wire length)

ø8, ø5/16"
Approx. 300

Manual override

(50.3)
1/4
(P, EA, EB port)
4-ø4.5
(For mounting)
33
EA

45
A A A A A
(Pitch)
90.3
(DIN: 69.4)
20 20

84.6 18.5 P = 16
107.2
20
66.7

68.1
119.8

(DIN: 4)
P

5.3
37.7

27.7

B B B B B
EB

(DIN: 8.6)

13.8
(4.9)

15.2
7.3

(Pitch)
18.5 P = 16
5.5 L2
L1

L plug connector: L M plug connector: M DIN terminal (D) M8 connector (WO)


(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
94.4
Max. 10

61.6 86.9
46.2 Pg7 75.6
M8 x 1 66.1
(Lead wire length) 48.6
Approx. 300 72.7
109.3

110.2
100.2

EA

EA
EA

EA

99.3

91.9
90.4

125.2

110.4
107.4

145.2

147
127
139.6

157.8

159.6

137.8
P

P
P

120

123
EB

EB
EB

EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52.5 68.5 84.5 100.5 116.5 132.5 148.5 164.5 180.5 196.5 212.5 228.5 244.5 260.5 276.5 292.5 308.5 324.5 340.5
L2 42 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330

83
SY3000/5000/7000 Base Mounted Type 42
SY3000: SS5Y3-42- Stations - C4, N3
C6, N7 -Q
Grommet (G)

(Light/surge voltage suppressor)

-+ -+

61
With interface regulator (with gauge)
45.6 A A

7.4

32
22.2
B B 75.5 ø15

10.5 7 (Pitch) One-touch fitting


1/8 P = 10.5
(Lead wire length)

(A, B port)
M5 (P, EA, EB port)
Approx. 300

Applicable tubing O.D.: ø4, ø5/32"


(External pilot port) 28 ø6, ø1/4"

With plug
15

(6)
8 Manual override
4-ø4.5

125.8
4-ø4.5

112.3
73.2 [75.4]
(For mounting)
EA

88.8 [93.2]
(For mounting)
16 14.7
19.4 16
X

A A A A A

EA
24.5 16
55.7
P

X
97.3

A A A
51

16
55.7
32.5

P
PE

6.6

B B B B B
EB

PE

24.5
B B B

EB
(3.2)

1.9

(28.5)
M5 (Pitch)
(Pilot EXH port) 14 P = 10.5 32
<In the case of external pilot> 4 L2 40 (Pitch)
L1 76 14 P = 10.5

L plug connector (L) M plug connector (M) M8 connector (WO)


(Lead wire length)
Approx. 300

61
45.6
65.5
M8 x 1 48
Approx. 300 72.1
(Lead wire length)
EA

EA
83.1

82.2
73.3

74.8
X

106.8
108.6

115.3

100.5
117.1

92
89
97.5
PE

PE
EB

EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 38.5 49 59.5 70 80.5 91 101.5 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5
L2 30.5 41 51.5 62 72.5 83 93.5 104 114.5 125 135.5 146 156.5 167 177.5 188 198.5 209 219.5

84
Type 42 Base Mounted
SY3000: SS5Y3-42- Stations -01 -Q
Grommet (G)

(Station 1) (Station n)

(Light/surge voltage suppressor)

- + -+
With interface regulator (with gauge)
61
45.6

A A

7.4

32
22.2
75.5 ø15
B B

7 (Pitch) 1/8
(Lead wire length)

M5 15 P=12.5 A, B port
Approx. 300

(External pilot port)


28

With plug
15

(6)
8 Manual override
4-ø4.5

125.9
(For mounting)

112.4
4-ø4.5
EA

16 14.7

73.3
X

19.4 16

(For mounting)
A A A A A

EA
88.8
24.6 16
55.8
P

X
A
51.1

A A
97.3

55.8

24.6 16
P
32.6
PE

B B B B
6.7

B
EB

PE
B B B

EB
1/8
1.8

P, EA, EB port

(28.5)
M5
(Pilot EXH port) (Pitch)
<In the case of external pilot> 18.5 P=12.5 32
4 L2 40 (Pitch)
76 18.5 P=12.5
L1

L plug connector (L) M plug connector (M) M8 connector (WO)


(Lead wire length)
Approx. 300

61
45.6
65.5
M8 x 1 48
Approx. 300 72.1
(Lead wire length)
EA

EA
83.2

82.3
73.4

74.9
X

X
108.6

106.8
115.3

100.5
117.1

92
89
PE

PE
97.5
EB

EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 47.5 60 72.5 85 97.5 110 122.5 135 147.5 160 172.5 185 197.5 210 222.5 235 247.5 260 272.5
L2 39.5 52 64.5 77 89.5 102 114.5 127 139.5 152 164.5 177 189.5 202 214.5 227 239.5 252 264.5

85
SY3000/5000/7000 Base Mounted Type 42
SY5000: SS5Y5-42- Stations - C4, N3
C6, N7 -Q
Grommet (G)

(Station 1) (Station n)
(Light/surge voltage suppressor) With interface regulator (with gauge)

ø15

With plug
- + - +

(14.5)
66.4
51
A A

37.8
27.3
7.8
B B 4-ø4.5
(For mounting)
9.5

107.9

EA
A A A

PE
(Pitch) One-touch fitting
15 P=16
A, B port

20

67.9
P
(Lead wire length)

M5 Applicable tubing O.D.: ø6,ø1/4"


Approx. 300

(Pilot EXH port) ø8, ø5/16"

X
B B B

EB
28.9
<In the case of external pilot> Manual override
34
17.6
4-ø4.5

(49.1)
(For mounting)
EA
PE

(DIN : 70.6)
24

A A A A A 91.5
20 20

107.2 38
28.9 20
P

69.3
67.9

119.8

50
23.6

(Pitch)
38.9

(DIN: 5.2)

18 89.6
X

P=16
EB

6.5

B B B B B

1/4
(DIN: 7.4)
(4.9)

6.1

P, EA, EB port
M5 (Pitch)
(External pilot port) 18 P=16
5 L2
L1

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

Applicable cable O.D.


ø3.5 to ø7
(Lead wire length)
Approx. 300

99.2
Max. 10

66.4 91.7
51 Pg7 80.4
(Lead wire length) M8 x 1 70.9
Approx. 300 77.5 53.4
100.5
EA

EA

111.4

EA
110.5
101.4

EA
91.6

PE

PE
PE
PE

127

125.2

93.1
107.4
139.6

137.8
145.2

110.4
147

P
P

120

P
157.8

159.6

123
X
X

X
EB

EB

EB
EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 52 68 84 100 116 132 148 164 180 196 212 228 244 260 276 292 308 324 340
L2 42 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330

86
Type 42 Base Mounted
SY5000: SS5Y5-42- Stations -02 -Q
Grommet (G)

(Station 1) (Station n)

(Light/surge voltage suppressor)

- + - +
66.4

A
51

37.8
9.8
27.3
B B
With interface regulator (with gauge)
8.5 1/4
(Pitch)
M5 (A, B port) ø15
(Lead wire length)

19 P=17.5

With plug
Approx. 300

(Pilot EXH port)

(14.5)
<In the case of external pilot> Manual override
34
17.6 4-ø4.5 4-ø4.5
(For mounting) (For mounting)

108
EA
A A A

PE
(DIN: 70.7)
A A A A A
EA

23.6 24
PE

91.6
20 20

107.2

20
P

68
20

69.4
119.8
P

68

(DIN: 5.3)

B B B

X
EB
39

B B B B B

29
6.6
X
EB

29

1/4
(DIN: 7.3)

(P, EA, EB port)

(49.1)
6

M5
(External pilot port) (Pitch)
21 P=17.5 37.8
5 L2 49.8 (Pitch)
21 P=17.5
L1 89.4

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)
(Lead wire length)

Applicable cable O.D.


Approx. 300

ø3.5 to ø7
99.2
Max. 10

66.4 91.7
Pg7 80.4
51 M8 x 1 70.9
(Lead wire length)
Approx. 300 77.5 53.4
110.6
101.5

100.6
EA

EA
111.5
PE
EA

PE

PE
PE

93.2
91.7
139.6

107.4

145.2

125.2

110.4
127

EA

137.8
157.8

147
P
P

120

123
P

159.6
X

EB
X

EB

X
EB
EB

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 59.5 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5 252 269.5 287 304.5 322 339.5 357 374.5
L2 49.5 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5 242 259.5 277 294.5 312 329.5 347 364.5

87
SY3000/5000/7000 Base Mounted Type 42
SY7000: SS5Y7-42- Stations -02, C10, N11 -Q
Grommet (G)

(Station 1) (Station n)

For 1 4 (Light/surge
voltage suppressor)

-+ -+ -+ -+
73 [80]

57.6
57.6

A A A A With interface regulator (with gauge)


73

41
41

9.4
9.4

28.9
28.9

B B B B

With plug
ø15

(21.8)
7 (Pitch) 1/4 7 One-touch fitting
P=19 (Pitch)
24 A, B port 24 P=19 A, B port
Applicable tubing O.D.: ø10, ø3/8"
L1
(Lead wire length)

6 L2 Manual override
Approx. 300

M5 4-ø4.5
(Pilot EXH port)

120.1
(For mounting)

EA
<In the case of external pilot>
A A A

PE
37
19.1

21
72.9
P

31.4
EB
B B B

X
A A A A A
EA

102.3
PE

26.6 26
21 21

(DIN: 81.4)

121.4
31.4 21

80.1
134.4
72.9
P

41.9

(DIN: 1.8)
X

(64.4)
EB

B B B B B
3.1
(5.5)

41
(DIN: 11.2)
9.9

1/4 55.5
4-ø4.5 (Pitch)
P, EA, EB port (Pitch) 101 21 P=19
M5 21 P=19 (For mounting)
(External pilot port)

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

Applicable cable O.D.


ø3.5 to ø7
(Lead wire length)
Approx. 300

107.5
Max. 10

73
100
57.6 Pg7 88.7 77.5
(Lead wire length)
84.1 60
Approx. 300
M8 x 1
122.2
121.3

111.3
112.2

103.9
EA
EA
EA
PE

102.4
EA

PE

PE
PE

121.6

161.2

139.4
141.2

159.4

124.6
134.6

172.4

174.2

152.4

137.6
154.2

P
P
P
P

EB
EB

X
EB
X

X
EB
X

Note) Refer to back page 12 for


dimensions of connector types.

Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations


L1 61 80 99 118 137 156 175 194 213 232 251 270 289 308 327 346 365 384 403
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391

88
5 Port Solenoid Valve
Series SY9000
Base Mounted
Type 43 Stacking Type/Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 9 43 05 U C8 -Q Example
Double solenoid (24 VDC)
Manifold series SY9240-5LOZ-Q (2 sets)

9 SY9000 Single solenoid (24 VDC)


SY9140-5LOZ-Q (2 sets)
Thread type Blanking plate assembly
Valve stations - Rc SY9000-26-2A-Q (1 set)
Symbol Stations F G Cylinder port size
02 2 stations N NPT -+
C12: With one-touch fitting for ø12
...

...

-+
T NPTF -+
20 20 stations -+

∗ This also includes the


number of blanking Sta
plate assemblies. Option tio
ns
Symbol Mounting
Manifold base (5 stations)
P, R port outlets - Direct mounting 3
2 SS5Y9-43-05-C12-Q
Symbol Port outlet Applicable stations D DIN rail mounting (with DIN rail) 1
U U side DO DIN rail mounting (without DIN rail)
2 to 10 stations
D D side When a longer DIN rail is desired than
D∗ the specified stations, specify the station
B Both sides 2 to 20 stations number to be required into ∗ mark.
SS5Y9-43-05B-C12-Q 1 set (Type 43, 5 station manifold base part no.)
A, B port size ∗ SY9000-26-2A-Q 1 set (Blanking plate assembly part no.)
SUP/EXH block assembly specifications Thread piping ∗ SY9140-5LOZ-Q 2 sets (Single solenoid part no.)
Symbol Specifications Symbol Port size ∗ SY9220-5LOZ-Q 2 sets (Double solenoid part no.)
- Standard/Internal pilot specification 02 14
R External pilot specification 03 38
The asterisk denotes the symbol for assembly.
S Internal pilot/Built-in silencer One-touch fitting (Metric size) Prefix it to the part nos. of the solenoid valve, etc.
RS External pilot/Built-in silencer Symbol Port size
Add the valve and option part number under the manifold base part
C8 One-touch fitting for ø8 number. In the case of complex arrangement, specify them on the
C10 One-touch fitting for ø10 manifold specification sheet.
C12 One-touch fitting for ø12
M Mixed
One-touch fitting (Inch size)
Symbol Port size
N9 One-touch fitting for ø 5 16"
N11 One-touch fitting for ø 3 8"
M Mixed
∗ In the case of mixed specifications
(M), indicate separately on the
manifold specification sheet.

89
SY9000 Base Mounted Type 43
How to Order Valve

SY 9 2 40 5 L -Q

Series Manual override


9 SY9000 - Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type

Type of actuation
1 2 position single
2 2 position double Light/surge voltage suppressor
3 3 position closed center
Electrical entry for G, H, L, M, W
4 3 position exhaust center
5 3 position pressure center - Without light/surge voltage suppressor
S With surge voltage suppressor
Z With indicator light and surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
Pilot type U With light/surge voltage suppressor (Non-polar type)
Nil Internal pilot ∗ Power saving circuit is only available in the "Z" type.
R External pilot

Electrical entry for D


- Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Coil specifications Z With light/surge voltage suppressor (Non-polar type)
Nil Standard ∗ DOZ is not available.
With power saving circuit ∗ For AC voltage valves there is no “S” option. It is already
T (24, 12 VDC only) built-in to the rectifier circuit.
∗ Power saving circuit is not
available in the case of D,
DO or W type.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 200, 24, 12, 6, 5, 3 VDC
Rated voltage 220 VAC
For DC Grommet L plug connector M plug connector DIN terminal M8 connector ∗
5 24 VDC G: Lead wire L: With lead wire M: With lead wire D: With connector WO: Without connector
6 12 VDC length 300 mm (Length 300 mm) (Length 300 mm) DO: Without cable
H: Lead wire LN: Without lead wire MN: Without lead wire connector W: With connector
V 6 VDC
length 600 mm LO: Without connector MO: Without connector cable Note 1)
S 5 VDC
R 3 VDC ∗ LN, MN type: with 2 sockets.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also
For AC ( 50 60 Hz)
available. For details, refer to page 210.
1 100 VAC ∗ For connector cable of M8 connector, refer to back page 12.
2 200 VAC ∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For
3 110 VAC [115 VAC] details, see page 211.
4 220 VAC [230 VAC] Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back
page 13.
∗ DC specifications of Type D
and DO is only available with
12 and 24 VDC.
∗ AC specification is only
available with D and DO type.

90
Type 43 Base Mounted
Manifold Specifications

Model SS5Y9-43
Applicable valve SY940
Manifold type Stacking type
P(SUP)/R(EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations (1)
A, B port Location Base
Porting specifications Direction Side
P, EA, EB port C12 (One-touch fitting for ø12)
14
Port 38
size A, B port C8 (One-touch fitting for ø8)
C10 (One-touch fitting for ø10)
C12 (One-touch fitting for ø12)
Manifold base weight
W = 107n + 330
W (g), n: Stations
Note 1) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA/EB
port on both sides.
Note 2) Refer to “Manifold Option” on page 109.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 14/2 (PA/B) 4/25/3 (A/BEA/EB)
(P, EA, EB) (A, B) C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]* C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]*
SS5Y9-43 C12 C12 6.4 0.29 1.6 1617 7.3 0.29 1.8 1845
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

91
SY9000 Base Mounted Type 43
02, C8, N9
SY9000: SS5Y9-43- Stations D - 03, C10,
C12
N11
(-D)-Q
Grommet (G)
(Station n) (Station 1)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations (Light/surge voltage suppressor)

Height when using DIN rail


L1 148 173 198 223 248 260.5 285.5 310.5 335.5
L2 137.5 162.5 187.5 212.5 237.5 250 275 300 325 -+ -+ -+ -+ -+

L3 117 141 165 189 213 237 261 285 309

94.2
L4 15.5 16 16.5 17 17.5 12 12.5 13 13.5

(6.7)
78.8
L5 103

66.8
127 151 175 199 223 247 271 295

20
(Lead wire length)
Approx. 300
U side D side

(5.4)
(5.5)
Manual override
DIN rail holding screw
<When attaching the DIN rail>

(For DIN : 79.75)


Tightening torque: 0.55 to 0.65N·m

(1/4, 3/8)
: 63.25)
(For DIN
78.4

81
67.8
B B B B B

61.9
164.3

8
67.6

147.8
5.5
35

: 43, 75)
(For DIN
40.7

41.5
A A A A A

63.7
9

DIN rail
4-ø6.2 L5 7 Silencer
∗ When P, R port outlets are indicated on the D side, the P, R (Mounting hole when L3 (L4) (Air discharge port)
ports on the opposite side are plugged. not using DIN rail)
L2 5 (with built-in
With External Pilot Specifications (Rail mounting hole pitch: 12.5) silencer specifications)

11 18.3 L1
(Pitch)
3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
P=24 24.3 22.3
63.3

18.8
18.8
79.8

18
3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
39.3

39.3
40.1
1 2 P 2 B 2 B 2 B 2 B 1 B P

Plug
1 2 P 2 B 2 B 2 B 2 B 1 B P

One-touch fitting
-+ -+
One-touch fitting [1(P), 3/5(R) port]
(PE: Pilot EXH port) [1(P), 3/5(R) port]
One-touch fitting (X: External pilot port) One-touch fitting
Applicable tubing O.D.: ø6, ø1/4"
-+ -+
Applicable tubing O.D.: ø12, ø3/8"
Applicable tubing O.D.: ø6, ø1/4" [4(A), 2(B) port]
Applicable tubing O.D.: ø8, ø5/16" 1/4,3/8
∗ Air discharge port on the built-in silencer type and the external pilot’s : ø10, ø3/8" [4(A), 2(B) port]
extracting position are in the D side. : ø12

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

M8 x 1
184.1

164.5

202.3

204.1
182.3

167.5
167.6

185.8

187.6

165.8
148

151
65.25
63.8

72.65
73.6

82.7

83.6
(Lead wire length)
Approx. 300

Approx. 300 105.3 81.2


(Lead wire length) 109.2 98.7
78.8 Pg7
Max. 10

120.5
94.2 128

Applicable cable O.D.


ø3.5 to ø7 Note) Refer to back page 12 for
dimensions of connector types.

92
Type 43 Base Mounted
02, C9, N9
SY9000: SS5Y9-43- Stations U - 03, C10,
C12
N11
(-D)-Q
Grommet (G)
(Station n) (Station 1)
(Light/surge voltage suppressor)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 148 173 198 223 248 260.5 285.5 310.5 335.5 -+ -+ -+ -+ -+
L2 137.5 162.5 187.5 212.5 237.5 250 275 300 325

Using DIN rail


L3 117 141 165 189 213 237 261 285 309

94.2

(6.7)
L4 15.5 16 16.5 17 17.5 12 12.5 13 13.5

78.8
66.8
L5 103 127 151 175 199 223 247 271 295

20
Approx. 300
(Lead wire length)
U side D side

(5.4)
DIN rail holding screw Manual override
<When attaching the DIN rail>
Tightening torque: 0.55 to 0.65 N·m 4-ø6.2

(For 1/4, 3/8)


(DIN: 79.75)
(Mounting hole when
not using DIN rail)

(DIN: 63.25)
78.4

81
67.8
B B B B B

61.9
8
164.3

147.8
67.6
35
5.5

(DIN: 42.75)
40.7

41.5
A A A A A

63.7
9

DIN rail

∗ When P, R port outlets are indicated on the U side, the P, R Silencer (Air discharge port) L5 7
L3 (L4)
ports on the opposite side are plugged. (with built-in silencer L2 5
With External Pilot Specifications specifications) (Rail mounting hole pitch: 12.5
18.3 11 L1
(Pitch)
P=24 24.3 22.3
3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
63.3
79.8

18.8
18.8

18
3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
39.3

39.3
40.1
1 2 P 2 B 2 B 2 B 2 B 1 B P

-+ -+ 1 2 P 2 B 2 B 2 B 2 B 1 B P

One-touch fitting One-touch fitting


[1(P), 3/5(R) port] Plug
(X: External pilot port) One-touch fitting
Applicable tubing O.D.: ø6, ø1/4" Applicable tubing O.D.: ø12, ø3/8" [1(P), 3/5(R) port]
(PE: Pilot EXH port) -+ -+

Applicable tubing O.D.: ø6, ø1/4" One-touch fitting


[4(A), 2(B) port] 1/4,3/8
∗ Air discharge port on the built-in silencer type and the external pilot’s [4(A), 2(B) port]
extracting position are in the D side. Applicable tubing O.D.: ø8, ø5/16"
: ø10, ø3/8"
: ø12

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

M8 x 1
164.5

202.3

204.1
182.3

167.5
185.8

187.6

165.8
184.1

148

151
167.6

65.25
63.8

72.65
73.6

82.7

83.6
(Lead wire length)
Approx. 300

Approx. 300 105.3 81.2


(Lead wire length) 109.2 98.7
78.8 Pg7
Max. 10

120.5
94.2 128

Applicable cable O.D. Note) Refer to back page 12 for


ø3.5 to ø7 dimensions of connector types.

93
SY9000 Base Mounted Type 43
02, C8, N9
SY9000: SS5Y9-43- Stations B - 03, C10,
C12
N11
(-D)-Q
Grommet (G)
(Station n) (Station 1)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 148 173 198 223 248 260.5 285.5 310.5 335.5 (Light/surge voltage suppressor)
L2 137.5 162.5 187.5 212.5 237.5 250 275 300 325
L3 117 141 165 189 213 237 261 285 309 -+ -+ -+ -+ -+
L4 15.5 16 16.5 17 17.5 12 12.5 13 13.5

Using DIN rail


L5 103 127 151 175 199 223 247 271 295

94.2

(6.7)
78.8
66.8
Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
L1 360.5 385.5 410.5 435.5 460.5 485.5 510.5 535.5 560.5 573

20
L2 350 375 400 425 450 475 500 525 550 562.5
L3 333 357 381 405 429 453 477 501 525 549
L4 14

(Lead wire length)


14.5 15 15.5 16 16.5 17 17.5 18 12 U side D side

Approx. 300
L5 319 343 367 391 415 439 463 487 511 535

(5.4)
Manual override
DIN rail holding screw
<When attaching the DIN rail>
Tightening torque: 0.55 to 0.65 N·m

(For 1/4, 3/8)


(DIN : 79. 75)

(DIN: 42, 75) (DIN: 63.25)


78.4

81
67.8
B B B B B

61.9
8
164.3

147.8
67.6

5.5
35
40.7

41.5
A A A A A

63.7
9

DIN rail
Silencer (Air discharge port)
∗ When P, R port outlets are indicated on the B side, the P, R ports 4-ø6.2 L5 7 (with built-in
on the both sides are in the open state. (Mounting hole L3 (L4) silencer
specifications)
With External Pilot Specifications when not using L2 5
DIN rail) (Rail mounting hole pitch: 12.5)
18.3 11
L1
3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
(Pitch)
P=24 24.3 22.3
63.3
79.8

18.8

18.8
18
1 2 P 2 B 2 B 2 B 2 B 1 B P 3/5 4 R 4 A 4 A 4 A 4 A 3/5 A R
39.3

40.1
39.3
-+ -+
One-touch fitting 1 2 P 2 B 2 B 2 B 2 B 1 B P
One-touch fitting
(X: External pilot port) One-touch fitting [1(P), 3/5(R) port]
Applicable tubing O.D.: ø6, ø1/4" (PE: Pilot EXH port) Applicable tubing O.D.: ø12, ø3/8"
Applicable tubing O.D.: ø6, ø1/4"
-+ -+

One-touch fitting
∗ Air discharge port on the built-in silencer type and the external pilot’s 1/4,3/8
[4(A), 2(B) port]
extracting position are in the B side (both sides). Applicable tubing O.D.: ø8, ø5/16" [4(A), 2(B) port]
: ø10, ø3/8"
: ø12

L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

M8 x 1
184.1

164.5

202.3

204.1
182.3

167.5
167.6

185.8

187.6

165.8
148

151
65.25
63.8

72.65
73.6

82.7

83.6
(Lead wire length)
Approx. 300

Approx. 300 105.3 81.2


(Lead wire length) 109.2 98.7
78.8 Pg7
Max. 10

120.5
94.2 128

Applicable cable O.D.


ø3.5 to ø7 Note) Refer to back page 12 for
dimensions of connector types.

94
5 Port Solenoid Valve
Type 41P Series SY3000/5000/7000
Base Mounted
Type 42P Bar Stock Type/Flat Ribbon Cable
How to Order Manifold How to Order Valve Manifold Assembly (Example)

Type 41P/Compact style


Example Blanking plate assembly

SS5Y 5 41P 05 C8 -Q SY3000-26-10A-Q(1set)


Single solenoid (24 VDC)
SY3140-5LOU-Q(3set)
Double solenoid (24 VDC)
Manifold series Stations Thread type
SY3240-5LOU-Q(2set)
3 SY3000 03 3 stations - Rc
5 SY5000 F G
...

...

12 12 stations (Single solenoid) Connector assembly


N NPT
T NPTF SY3000-37-3A
∗ SS5Y3 has 4 to (Double solenoid) Connector assembly
12 stations. ∗ Except for M5
SY3000-37-4A

A, B port size
Thread piping Sta
tio
ns
Symbol Port size Applicable series
M5 M5 SY3000
01 18 SY5000
3
2
1 Manifold base (5 stations)
One-touch fitting (Metric size) One-touch fitting (Inch size) SS5Y3-41P-06-C6-Q
Symbol Port size Applicable series Symbol Port size Applicable series SS5Y3-41P-06-C6-Q 1 set (Type 41, 6 stations manifold base part no.)
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" ∗ SX3000-26-10A-Q 1 set (Blanking plate assembly part no)
SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" ∗ SY3140-5LOU-Q 3 sets (Single solenoid part no.)
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" ∗ SY3240-5LOU-Q 2 sets (Double solenoid part no.)
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16" ∗ SY3000-37-3A 3 sets (Connector assembly part no.)
∗ SY3000-37-4A 2 sets (Connector assembly part no.)

Type 42P/Common external pilot


The asterisk denotes the symbol for assembly.

SS5Y 5 42P 05 C8 -Q
Prefix it to the part nos. of the solenoid valve, etc.

Add the valve and option part number under the manifold base part
number. In the case of complex arrangement, specify them on the
manifold specification sheet.
Manifold series Stations Thread type
3 SY3000 03 3 stations - Rc
5 SY5000 F G
...

...

7 SY7000 12 12 stations N NPT


∗ SS5Y3 has 4 to
T NPTF
12 stations.

A, B port size
Thread piping
Symbol Port size Applicable series
01 18 SY3000
02 14 SY5000
02 14 SY7000

One-touch fitting (Metric size) One-touch fitting (Inch size)


Symbol Port size Applicable series Symbol Port size Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
SY3000 SY3000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
C10 One-touch fitting for ø10 SY7000 N9 One-touch fitting for ø 16" SY7000
5

95
SY3000/5000/7000 Base Mounted Type 41P 42P
Type

How to Order Valve

Light/surge voltage suppressor


Z With light/surge voltage suppressor
With light/surge voltage suppressor
U
Rated voltage (Non-polar type)
5 24 VDC Note) Z: Positive common specifications only.
6 12 VDC

For DC: SY 5 1 40 5 LO Z -Q

Series Manual override


3 SY3000 - Non-locking push type
5 SY5000 D Push-turn locking slotted type
7 SY7000 E Push-turn locking lever type

Type of actuation
1 2 position single
2 2 position double
3 3 position closed center
4 3 position exhaust center
5 3 position pressure center

Pilot type
- Internal pilot
R External pilot

How to Order Connector Assembly


For 12, 24 VDC
For DC For SY3000 For SY5000/7000
For single solenoid SY3000-37-3A SY5000-37-3A
Double solenoid,
3 position type SY3000-37-4A SY5000-37-4A
Single with
spacer assembly SY5000-37-3A SY5000-37-5A
Double, 3 position
with spacer assembly SY3000-37-6A SY5000-37-6A

96
Type 41P 42P Base Mounted Type

Flat Ribbon Cable Manifold Specifications

 Multiple valve wiring is Model SS5Y3-41P SS5Y3-42P SS5Y5-41P SS5Y5-42P SS5Y7-42P


Applicable valve SY340 SY540 SY740
simplified through the use Manifold type Single base/B mount
of the flat cable connector. P(SUP)/R(EXH) Common SUP, Common EXH
 Clean appearance Valve stations 4 to 12 stations (1) 3 to 12 stations Note 1)
A, B port Location Base
In the case of a flat ribbon cable type, each Porting specifications Direction Side
valve is wired on the print board of manifold 18 14 14
P, EA, EB port
base to allow the external wiring to be piped all Port M5 18 18 14
14
together with 26 pins MIL connector. size A, B port C4 (One-touch fitting for ø4) C4 (One-touch fitting for ø4) C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6)
C10 (One-touch fitting for ø10)
C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6) C8 (One-touch fitting for ø8) C8 (One-touch fitting for ø8)
Manifold base weight
W = 39n + 83 W = 48n + 99 W = 67n + 118 W = 88n + 151 W = 109n + 174
W (g), n: Stations
Applicable flat ribbon cable connector Flat ribbon cable connector, Socket: 26 pins MIL type with strain relief, Conforming to MIL-C-83503
Internal wiring In common between +COM and –COM (Z type: +COM only).
Rated voltage 12, 24 VDC
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its
equivalent.
Note 3) Refer to “Manifold Option” on page 109.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
SS5Y3-41P 18 C6 0.75 0.19 0.18 179 0.81 0.23 0.20 197
SS5Y3-42P 18 C6 0.75 0.20 0.18 180 0.82 0.20 0.20 196
SS5Y5-41P 14 C8 1.8 0.23 0.44 439 1.9 0.16 0.45 445
SS5Y5-42P 14 C8 1.9 0.20 0.46 455 1.9 0.12 0.43 436
SS5Y7-42P 14 C10 3.0 0.25 0.75 740 3.0 0.12 0.66 688
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

Internal Wiring of Manifold (Non-polar type)

• For more than 10 stations, both poles of the common should be


Station 12 Station 4 Station 3 Station 2 Station 1 wired.
Coil
• For single solenoid, connect to the solenoid A side.
• The maximum number of stations that can be accommodated is
12. For more stations, please contact SMC.

Station
Triangle mark
Solenoid B side
position

Note)
Connector Wiring unit
Solenoid A side

Caution
Connected on PCB Common (–) (+)
Common (–) (+)

Station 12 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 4 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 3 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 2 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 1 Solenoid B (+) (–)


Solenoid A (+) (–)

• For non-polar (U) valves, the electrical DC connections can be


used with either positive and negative COM. For type (Z), only use
with positive COM as the valve does not operate correctly when
used with negative COM.
{

{
{

(Max. 12 stations) Triangle mark


Note)
Terminal no. is not indicated on the connector. The terminal no.
indicated in the connection schematic of connector, as shown
in the reference, means a correlation of 1, 2, 3····26 from the Reference figure
triangle mark side on the flat ribbon cable of connector.

97
SY3000/5000/7000 Base Mounted Type 41P
SY3000: SS5Y3-41P- Stations -M5, C4, N3
C6, N7 -Q

With interface regulator (with gauge)

(Pitch)
72.5 P=12.5 18.5
36.5 4
28.5 -+

-+

(29.5)
(Station n) (Station 1)
22.5

(Light/surge voltage suppressor)


EB

B B B
53.7

16
P

A A A
EA

57.5
111.3
124.8

35.3
28.5

9.4
-+ -+ -+
(With plug)

4-ø4.5 28.5
Applicable connector: 26 pins MIL type
(7)

(For mounting) with strain relief


(Conforming to MIL-C-83503)

72 ø15 L1
L2 4

-+
13.6 -+ -+
4-ø4.5
(3.2)

8.5
2.9

(For mounting)

22.5
30.5

5.6
EB

117.1

B B B B B
15.5 15.5

108.6
53.7

50

16
P

82.1

A A A A A
87.5
EA

14

1/8
-+ -+ -+ -+ -+
P, EA, EB port
Manual override
(Pitch)
Triangle mark
P=12.5 18.5

For M5
One-touch fitting
(Pitch) (Pitch)
P=12.5 15 A, B port P=12.5 15
M5 7 Applicable tubing O.D.: ø4, ø5/32" 7
: ø6, ø1/4"
6.5

6.5

A, B port
20.7

20.7

B B B B

A A A A

Stations n 4 5 6 7 8 9 10 11 12
L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

98
Type 41P Base Mounted
SY5000: SS5Y5-41P- Stations -01, C6,N7
C8,N9 -Q
(Station n) (Station 1)

(Light/surge voltage suppressor)

For 1 8
(Pitch)
P=17.5 18
1/8 9

61.6
7.5
A, B port

42.7
10.9
33
B B

23
A A
28.5

Applicable connector: 26 pins MIL type


with strain relief
(Conforming to MIL-C-83503)
L1
L2 5
(Pitch)
P=17.5 21
-+

15.2 -+
(4.9)

13.8

7.3
4-ø4.5
(For mounting)

20 27.8
5.3
37.7
EB

B B B B B
139.6
20

66.7

68.2
127
P

100.2

100.5
20

A A A A A
EA

16

Manual
1/4 override
P, EA, EB port -+ -+ -+ -+ -+

Triangle mark

With interface regulator (with gauge) One-touch fitting (Pitch)


(Pitch) A, B port P=17.5 18
84.6 P=17.5 21 Applicable tubing O.D.: ø6, ø1/4" 9

7.5
45 5 ø8, ø5/16"
33 B B

-+ A A 23
(50.3)

-+

4-ø4.5
(For mounting)
27.7
EB

B B B
66.7

20
P

106.7

A A A
EA

With plug

-+ -+ -+
(14.5)

ø15

Stations n 3 4 5 6 7 8 9 10 11 12
L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5

99
SY3000/5000/7000 Base Mounted Type 42P
SY3000: SS5Y3-42P- Stations -01, C4, N3
C6, N7 -Q

With interface regulator (with gauge)

(Pitch)
76.5 P=12.5 18.5
40 4
32 -+

(28.5)
-+

16 24.5
EB

B B B
PE

55.7
P

A A A
X
EA

112.3
125.8

(Station n) (Station 1)
(Light/surge voltage suppressor)
With plug

-+ -+ -+
(6)

4-ø4.5
(For mounting)

61
75.5

11.6
ø15

38.8
32
Applicable connector: 26 pins MIL type 28.5
With strain releaf
(Conforming to MIL-C-83503)
M5
(Pilot EXH port) L1
<In the case of external pilot type L2 4
solenoid valve>
28
15
-+

4- ø4.5
-+ -+
(3.2)

8
1.9
6.6

(For mounting)

16 24.5
32.5
EB

117.1
16 19.4

B B B B B
PE

108.6
55.7
14.7 16

51
P

83.1

89.5
A A A A A
X
EA

14

1/8 -+ -+ -+ -+ -+

(P, EA, EB port)


Manual override
M5 (Pitch)
Triangle mark
(External pilot port) P=12.5 18.5
For 1 8
(Pitch) One-touch fitting (Pitch)
P=12.5 15 P=12.5 15
(A, B port)
1/8 7 Applicable tubing O.D.: ø4, ø5/32" 7
7.4

7.4

A, B port : ø6, ø1/4"


22.2

22.2

B B B B

A A A A

Stations n 4 5 6 7 8 9 10 11 12
L1 72.5 85 97.5 110 122.5 135 147.5 160 172.5
L2 64.5 77 89.5 102 114.5 127 139.5 152 164.5

100
Type 42P Base Mounted
SY5000: SS5Y5-42P- Stations -02,C6, N7
C8, N9 -Q
Grommet (G)
With interface regulator (with gauge)
(Pitch)
89.4 P=17.5 21
49.8 5
37.8
-+

(49.1)
-+

4-ø4.5 (Station n) (Station 1)


(Light/surge

28.9
(For mounting)
voltage suppressor)
EB

B B B
X

67.9

20
P

107.9

66.4
PE

A A A
EA

47.5
13.2
37.8
With plug
(14.5)

-+ -+ -+ 28.5
Applicable connector: 26 pins MIL type
ø15 Triangle mark With strain releaf
(Conforming to MIL-C-83503)

L1
L2 5
(Pitch)
M5 P=17.5 21
(External pilot port)
-+

34
(4.9)

17.6
-+
6.1

4-ø4.5
(For mounting)
20 28.9
6.5
38.9
EB

B B B B B
X

23.6

139.6
20

67.9

69.3
127
P

101.4

101.7
20
24
PE

A A A A A
EA

16

Manual
override
1/4 -+ -+ -+ -+ -+
(P, EA, EB port)
Triangle mark
M5
(Pilot EXH port)
<In the case of external pilot type solenoid valve>

For 1 4

(Pitch) (Pitch)
P=17.5 18 One-touch fitting P=17.5 18
1/4 9.5 (A, B port) 9.5
7.8

(A, B port) Applicable tubing O.D.: ø6, ø1/4"


ø8, ø5/16"
10

B B
27.5

27.3

B B

A A A A

Stations n 3 4 5 6 7 8 9 10 11 12
L1 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5
L2 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5

101
SY3000/5000/7000 Base Mounted Type 42P
SY7000: SS5Y7-42P- Stations -02, C10, N11 -Q
Grommet (G)

With interface regulator (with gauge)


(Pitch) 101
P=20.5 23.5 55.5
6 (64.4) 41

-+

(Station n) (Station 1)
-+

(Light/surge voltage suppressor)


31.4

-+ -+ -+ -+ -+
B B B
EB
X

72.9

73
21

52.6
P

41
120.1

17.7
PE

EA

A A A

4-ø4.5
(For 28.5
mounting) Applicable connector: 26 pins MIL type
With strain releaf
-+ -+ -+ (Conforming to MIL-C-83503)
With plug
(21.7)

ø15
L1
Manual override L2 6
M5 (Pitch)
(External pilot port) -+ P=20.5 23.5
37 -+ -+
(5.5)

9.9

19.1
3.1

31.4
41.9

B B B B B
EB
X

26.6

154.2
21

72.9

141.2

80.1

21
P

106.7
112.2
21
26
PE

EA

A A A A A
16

1/4 4-ø4.5
(For mounting)
(P, EA, EB port) -+ -+ -+ -+ -+
Triangle mark
M5
(Pilot EXH port)
<In the case of external pilot type solenoid valve>

For 1 4

(Pitch) (Pitch)
P=20.5 19.5 One-touch fitting P=20.5 19.5
1/4 7 (A, B port) 7
9.4

9.4

(A, B port) Applicable tubing O.D.: ø10, ø3/8"


28.9

28.9

B B B B

A A A A

-+ -+ -+ -+ -+ -+

Stations n 3 4 5 6 7 8 9 10 11 12
L1 88 108.5 129 149.5 170 190.5 211 231.5 252 272.5
L2 76 96.5 117 137.5 158 178.5 199 219.5 240 260.5

102
5 Port Solenoid Valve
Series SY9000
Base Mounted
Type 43P Stacking Type/Flat Ribbon Cable
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y9 43P 05 U C8 -Q Example Lead wire cover


SY9000-41-1
Double solenoid (24 VDC)
SY9240-5LOU-Q (2 sets)
Manifold series
(Single solenoid) Connector assembly Single solenoid (24 VDC)
9 SY9000 SY9140-5LOU-Q (2 sets)
SY9000-37-1A
Thread type (Double solenoid) Connector assembly
Valve stations - Rc SY9000-37-2A
Symbol Stations F G Blanking plate assembly
04 4 stations N NPT SY9000-26-4A-Q (1 set)
Cylinder port size
...

...

T NPTF
12 12 stations C12: With one-touch fitting for ø12
∗ This also includes the
number of blanking Option Sta
plate assemblies. tio
Symbol Mounting ns
P, R port outlets - Direct mounting
D DIN rail mounting (with DIN rail) 3 Manifold base (5 stations)
Symbol Port outlet Applicable stations 2
D0 DIN rail mounting (without DIN rail) SS5Y9-43P-05B-C12-Q
U U side 1
4 to 10 stations When a longer DIN rail is desired than
D D side
D∗ the specified stations, specify the station
B Both sides 4 to 12 stations number to be required into ∗ mark.
SS5Y9-43P-05B-C12-Q 1 set (Type 43, 5 station manifold base part no.)
A, B port size ∗ SY9000-26-4A-Q 1 set (Blanking plate assembly part no.)
SUP/EXH block assembly specifications Thread piping ∗ SY9140-5LOU-Q 2 sets (Single solenoid part no.)
∗ SY9240-5LOU-Q 2 sets (Double solenoid part no.)
Symbol Specifications Symbol Port size
∗ SY9000-37-1A 2 sets (Connector assembly part no.)
- Standard/Internal pilot specification 02 14
∗ SY9000-37-2A 2 sets (Connector assembly part no.)
R External pilot specification 03 38 ∗ SY9000-41-1 1 set (Lead wire cover)
S Internal pilot/Built-in silencer
RS External pilot/Built-in silencer One-touch fitting (Metric size) The asterisk denotes the symbol for assembly.
Symbol Port size Prefix it to the part nos. of the solenoid valve, etc.
C8 One-touch fitting for ø8 Add the valve and option part number under the manifold base part
C10 One-touch fitting for ø10 number. In the case of complex arrangement, specify them on the
C12 One-touch fitting for ø12 manifold specification sheet.
M Mixed

One-touch fitting (Inch size)


Symbol Port size
N9 One-touch fitting for ø5 16"
N11 One-touch fitting for ø 3 8"
M Mixed
∗ In the case of mixed specifications
(M), indicate separately on the
manifold specification sheet.

103
SY9000 Base Mounted Type 43P
How to Order Valve

Rated voltage Light/surge voltage suppressor


5 24 VDC Z With light/surge voltage suppressor
6 12 VDC
With light/surge voltage suppressor
U
(Non-polar type)

For DC: SY 9 1 40 5 LO Z -Q Note) Z: Positive common specifications only.

Series
9 SY9000

Type of actuation
1 2 position single
2 2 position double
3 3 position closed center
4 3 position exhaust center
5 3 position pressure center

Pilot type Manual override


- Internal pilot - Non-locking push type
R External pilot D Push-turn locking slotted type
E Push-turn locking lever type

How to Order Connector Assembly

For 12, 24 VDC


For DC For SY9000
For single solenoid SY9000-37-1A
Double solenoid,
3 position type SY9000-37-2A
Single with
spacer assembly SY9000-37-3A
Double, 3 position
with spacer assembly SY9000-37-4A

104
Type 43P Base Mounted
Flat Ribbon Cable Manifold Specifications

 Multiple valve wiring is Model SS5Y9-43P


Applicable valve SY940
simplified through the use of Manifold type Stacking type
the flat cable connector. P (SUP)/R (EXH) Common SUP, Common EXH
 Clean appearance Valve stations 4 to 12 stations Note 1)
A, B port Location Base
In the case of a flat ribbon cable type, each valve Porting specifications Direction Side
is wired on the print board of manifold base to C12 (One-touch fitting for ø12)
P, EA, EB port
allow the external wiring to be piped all together 14
with 26 pins MIL connector. 38
Port size
A, B port C8 (One-touch fitting for ø8)
C10 (One-touch fitting for ø10)
C12 (One-touch fitting for ø12)
Manifold base weight
W = 114n + 343
W (g) n: Stations
Applicable flat ribbon cable connector Flat ribbon cable connection, Socket: 26 pins MIL with strain relief, Conforming to MIL-C-83503
Internal wiring In common between +COM and –COM (Z type: +COM only)
Rated voltage 12, 24 VDC
Note 1) For more than 10 stations, supply pressure to P port on both sides and exhaust from
EA/EB port on both sides.
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or
its equivalent.
Note 3) Refer to “Manifold Option” on page 109.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
SS5Y9-43P C12 C12 6.4 0.29 1.6 1617 7.3 0.29 1.8 1845
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

Internal Wiring of Manifold (Non-polar type)

Station 12 Station 4 Station 3 Station 2 Station 1


Coil

Triangle mark
position

Note)
Connector
Connected on PCB Common (–) (+)
Common (–) (+)

Station 12 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 4 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 3 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 2 Solenoid B (+) (–)


Solenoid A (+) (–)

Station 1 Solenoid B (+) (–)


Solenoid A (+) (–)
{

Triangle mark
Note) (Max. 12 stations)
Terminal no. is not indicated on the connector. The terminal
no. indicated in the connection schematic of connector, as
shown in the reference, means a correlation of 1, 2, 3····26
from the triangle mark side on the flat ribbon cable of
Caution connector.
Reference figure

• For non-polar (U) valves, the electrical DC • For more than 10 stations, both poles of the common Station
connections can be used with either positive should be wired. Solenoid B side
and negative COM. For type (Z), only use with • For single solenoid, connect to the solenoid A side.
positive COM as the valve does not operate • The maximum number of stations that can be
correctly when used with negative COM. accommodated is 12. For more stations, please Wiring unit
Solenoid A side
contact SMC.

105
SY9000 Base Mounted Type 43P
C8, N9
02
SY9000: SS5Y9-43P- Stations D - 03 C10,
C12
N11
(-D)-Q
∗ When P, R port outlets are indicated on the D side, the P, R ports on the
opposite side are plugged.

(Light/surge voltage suppressor)

With External Pilot Specifications

(95.4)
94.2
11 18.3

66.8

64
3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R

27
20
63.3
79.8

(Height when using DIN rail)


1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P
Applicable connector: 26 pins MIL type
63
with strain relief
(Conforming to MIL-C-83503)

(6.7)
One-touch fitting One-touch fitting
(X: External pilot port) (PE: Pilot EXH port)
Applicable tubing O.D.: ø6, ø1/4" Applicable tubing O.D.: ø6, ø1/4"
∗ Air discharge port on the built-in silencer type and the external pilot’s
extracting position are in the D side.
U side D side
DIN rail holding screw
-+

(5.4)
(When attaching the DIN rail) -+

Tightening torque: (0.55 to 0.65) N·m

(1/4, 3/8)
78.4

81.1
67.8
B B B B B

61.9
8
184.1

67.6
167.6

35
40.7

41.5
A A A A A
5.5

73.6
Triangle
9

DIN rail mark


-+ -+ -+ -+ -+

Manual override
L5 7
4-ø6.2 L3 (L4)
(Mounting hole L2 5
when not using (Rail mounting hole pitch: 12.5)
DIN rail) L1
Silencer (Air discharge port)
(Station n) (Station 1) (with built-in silencer specifications)

(Pitch)
P = 24 24.3 22.2
18.8
18.8
18

3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R
39.3
40.1

39.3

1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P
Plug
[1(P), 3/5(R) port] One-touch fitting
[1(P), 3/5(R) port]
1/4, 3/8 Applicable tubing O.D.: ø12, ø3/8"
One-touch fitting
[4 (A), 2 (B) port]
[4(A), 2(B) port]
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8"
: ø12

Stations n 4 stations 5 6 7 8 9 10 stations


L1 198 223 248 260.5 285.5 310.5 335.5
L2 187.5 212.5 237.5 250 275 300 325
L3 165 189 213 237 261 285 309
L4 16.5 17 17.5 12 12.5 13 13.5
L5 151 175 199 223 247 271 295

106
Type 43P Base Mounted
C8, N9
02
SY9000: SS5Y9-43P- Stations U - 03 C10,
C12
N11
(-D)-Q
∗ When P, R port outlets are indicated on the U side, the P, R ports on the
opposite side are plugged.

(Station n) (Station 1)

(Light/surge voltage suppressor)

With External Pilot Specifications

(95.4)
94.2
3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R

66.8

64
63.3
79.8

27
20
1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P

(5.4) Height when using DIN rail


Applicable connector: 26 pins MIL type 63
18.3 11 with strain releaf
(Conforming to MIL-C-83503)
One-touch fitting One-touch fitting
(X: External pilot port) (PE: pilot EXH port)

(6.7)
Applicable tubing O.D.: ø6, ø1/4" Applicable tubing O.D.: ø6, ø1/4"

∗ Air discharge port on the built-in silencer type and the external pilot’s
extracting position are in the U side.

U side D side
DIN rail holding screw
-+
(5.4)

(When attaching the DIN rail) -+

Tightening torque: (0.55 to 0.65) N·m


4-ø6.2
(Mounting hole

(1/4, 3/8)
when not using
78.4

81.1
DIN rail)
B B B B B

67.8
61.9
8
184.1

67.6

167.6
35
40.7

41.5
A A A A A
5.5
73.6

DIN rail
-+ -+ -+ -+ -+
Triangle mark

Silencer Manual override


L5
(Air discharge port) L3 7 (L4)
(with built-in L2 5
silencer (Rail mounting hole pitch: 12.5)
specifications)
L1

One-touch fitting
[1(P), 3/5(R) port] (Pitch)
Applicable tubing O.D.: ø12, ø3/8" P = 24 24.3 22.2
18.8
18.8
18

3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R
39.3

39.3
40.1

1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P

Plug
One-touch fitting
[1(P), 3/5(R) port]
[4(A), 2(B) port]
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8" 1/4, 3/8
: ø12 [4 (A), 2 (B) port]

Stations n 4 stations 5 6 7 8 9 10 stations


L1 198 223 248 260.5 285.5 310.5 335.5
L2 187.5 212.5 237.5 250 275 300 325
L3 165 189 213 237 261 285 309
L4 16.5 17 17.5 12 12.5 13 13.5
L5 151 175 199 223 247 271 295

107
SY9000 Base Mounted Type 43P
C8, N9
02
SY9000: SS5Y9-43P- Stations B - 03 C10,
C12
N11
(-D)-Q
∗ When P, R port outlets are indicated on the B side, the P, R
ports on the both sides are in the open state.

(Station n) (Station 1)

(Light/surge voltage suppressor)


With External Pilot Specifications
1118.3

3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R

(95.4)
94.2
63.3

66.8
79.8

64
1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P

27
20
63

(5.4) (Height when using DIN rail)


One-touch fitting Applicable connector: 26 pins MIL type
One-touch fitting (PE: pilot EXH port) with strain relief
(X: External pilot port) Applicable tubing O.D.: ø6, ø1/4"
(Conforming to MIL-C-83503)
Applicable tubing O.D.: ø6, ø1/4"

(6.7)
∗ Air discharge port on the built-in silencer type and the external pilot’s
extracting position are in the B side (both sides).

U side D side
DIN rail holding screw
-+
(5.4)

(When attaching the DIN rail) -+

Tightening torque: (0.55 to 0.65) N·m

(1/4, 3/8)
78.4

81.1
67.8
B B B B B

61.9
8
184.1

67.6

167.6
35
40.7

41.5
A A A A A
5.5
73.6

DIN rail Triangle mark


-+ -+ -+ -+ -+

Manual Silencer (Air discharge port)


4-ø6.2 L5 override 7 (with built-in silencer
(Mounting hole L3 (L4) specifications)
when not using L2 5
DIN rail) (Rail mounting hole pitch: 12.5)
L1
(Pitch)
22.3 P = 2424.3 22.2
18.8
18.8
18

3/5 4 R 4 A 4 A 4 A 4 A 4 A 3/5 A R
39.3

39.3
40.1

1 2 P 2 B 2 B 2 B 2 B 2 B 1 B P

One-touch fitting
[4(A), 2(B) port] One-touch fitting
Applicable tubing O.D. : ø8, ø5/16"
[1(P), 3/5(R) port]
: ø10, ø3/8"
1/4, 3/8 Applicable tubing O.D.: ø12, ø3/8"
: ø12
[4 (A), 2 (B) port]

Stations n 4 stations 5 6 7 8 9 10 11 12 stations


L1 198 223 248 260.5 285.5 310.5 335.5 360.5 385.5
L2 187.5 212.5 237.5 250 275 300 325 350 375
L3 165 189 213 237 261 285 309 333 357
L4 16.5 17 17.5 12 12.5 13 13.5 14 14.5
L5 151 175 199 223 247 271 295 319 343

108
41 41P
Type 42 Type 42P Base Mounted
Type 43 43P Type

Manifold Option

 Type 41, 42, 43  Type 41P, 42P, 43P  Gasket assembly part no.
Blanking plate assembly Blanking plate assembly Round head combination screw

Gasket

Series Assembly part no. Series Assembly part no. Series Assembly part no.
SY3000 SY3000-26-9A-Q SY3000 SY3000-26-10A-Q SY3000 SY3000-GS-2
SY5000 SY5000-26-20A-Q SY5000 SY5000-26-21A-Q SY5000 SY5000-GS-2-Q
SY7000 SY7000-26-22A-Q SY7000 SY7000-26-23A-Q SY7000 SY7000-GS-2-Q
SY9000 SY9000-26-2A-Q SY9000 SY9000-26-4A-Q SY9000 SY9000-GS-2
Note) Gasket assembly
consists of mounting
screws and a gasket.

 Individual SUP spacer assembly  Individual EXH spacer assembly  Individual SUP spacer assembly
+ Individual EXH spacer assembly
(Double spacer)

t t
SUP port
EXH port

Series Assembly part no. Port size t Series Assembly part no. Port size t 5
E

SY3000 SY3000-38-2A-Q M5 11 SY3000 SY3000-39-2A-Q M5 11 EXH port


SY5000 SY5000-38-16∗A-Q 18 15 SY5000 SY5000-39-16∗A-Q 18 15
SY7000 SY7000-38-16∗A-Q 14 18 SY7000 SY7000-39-16∗A-Q 14 18 P

SY9000 SY9000-38-2∗A-Q 14 20 SY9000 SY9000-39-2∗A-Q 14 20 1

EXH port
Note) • The SUP port of SY3000, 5000 and Note) In case of 41P, 42P and 43P, for
7000 may be either on the lead wire protection of the wiring unit section
side or on the end plate side. (An from drainage, piping at the EA port
assembly is shipped under the should be arranged so that it will not
Type 41, 42 Type 45
condition shown in the figure.) be directly exposed to exhaust from
• The end plate side is only available the valve.
to SY9000.
[: Available : Not available —: Nonapplicable manifold]

Caution ∗ Thread type Individual SUP + Applicable manifold types


Series Individual EXP Port size 45-A
Mounting screw - Rc Assemble part no. 41 41P 42 42P 45 45
45-NA
tightening torques F G
SY3000 SY3000-120-2A-Q M5       
M2: 0.16 N·m N NPT
T NPTF SY5000 SY5000-75-1∗A-Q 1/8       
M3: 0.8 N·m
SY7000 SY7000-73-1∗A-Q 1/4     — — —
M4: 1.4 N·m
Note) The port on a spacer can be directed to the pilot valve side or end plate side. For mounting
the port to the pilot valve side, please make sure to connect the ports to protect the pilot
Warning valve wiring section from drainage.
The individual SUP spacer and EXH spacer can be mounted either on the upper side or
When mounting a valve or spacer on the manifold
lower side. (The above illustration shows the condition when the product is shipped out from
base or sub-plate, etc., those mounting directions a factory already assembled.)
are determined. If mounted in the wrong
direction, the equipment to be connected may
cause malfunction. Refer to external dimensions,
and then mount it.
109
41 41P
Type 42 Type 42P

Type 43 43P Type

Manifold Option
 SUP blocking disk (For SY9000)  Cable assembly
1
By installing a SUP blocking disk in the pressure supply passage of a manifold AXT100-FC26-


valve, it is possible to supply two or more different high and low pressures to 3 Red
one manifold.

Series No.
SY9000 SY9000-57-1A

 EXH blocking disk (For SY9000)


By installing an EXH blocking disk in the exhaust passage of a manifold valve, Terminal
it is possible to divide the valve’s exhaust so that it does not affect another number
valve. (Two blocking disks are needed to divide both exhausts.)

Connector Assembly for Flat Ribbon Cables


Series No.
Cable length (L) Ass’y part no. Note
SY9000 SY9000-57-1A
1.5m AXT100-FC26-1
Cable 26 core
3m AXT100-FC26-2
x 28 AWG
5m AXT100-FC26-3
 Label for block disk (For SY9000)
∗ For other commercial connectors, use a 20 pins with strain relief
The labels shown below are used on manifold stations containing SUP/EXH conforming to MIL-C-83503.
block disk(s) to show their location. (3 pcs. each)

VZ3000-123-1A
Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk Connector manufacturers’ example
• Hirose Electric Company
• Japan Aviation Electronics Industry, Ltd.
• Sumitomo 3M Limited
• J.S.T. Mfg. Co., Ltd.
• Fujitsu Limited
Note) When a block disk is concurrently ordered by specifying on the
manifold specification sheet, etc., a label will be stuck on the
position where block disk is mounted.
 Silencer with One-touch fitting (For SY9000)
 Plug (white)
The silencer plugs directly into the One-touch fittings of the manifold R These are inserted in unused cylinder ports and SUP, EXH ports.
(exhaust) port. Purchasing order is available in units of 10 pieces. ød
øD

For Series Model Effective area A B C A


SY9000 (ø12) AN300-KM12 41 mm2 ø25 70 98 L

 DIN Rail Dimensions/Weight for SY9000


VZ1000 11 4 Dimensions
Refer to L dimensions Applicable fittings size ød Model A L D
∗ Fill in  with an appropriate no. listed on the 4 KQ2P-04 16 32 6
table of DIN rail dimensions shown below. 6 KQ2P-06 18 35 8
L (10) 8 KQ2P-08 20.5 39 10
8
10 KQ2P-10 22 43 12
12 KQ2P-12 24 44.5 14
(24)
(35)
5.5

1 8" KQ2P-01 16 31.5 5


5 32" KQ2P-03 16 32 6
Rail mounting hole pitch: 12.5 1 4" KQ2P-07 18 35 8.5
No. 0 1 2 3 4 5 6 7 8 9
5 16" KQ2P-09 20.5 39 10
L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5
3 8" KQ2P-11 22 43 11.5
Weight (g) 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3
No. 10 11 12 13 14 15 16 17 18 19
L Dimension 223 235.5 248 260.5 273 285.5 298 310.5 323 335.5
Weight (g) 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7 84.9
No. 20 21 22 23 24 25 26 27 28 29
L Dimension 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5
Weight (g) 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5
Note) • For DIN rail, refer to back page 10.
• Refer to L1 dimension on pages starting with pages 106 through
108 for lengths that correspond to the number of manifold stations.

110
41 41P
Type 42 Type 42P Base Mounted

Manifold Option
 How to Order Interface Regulator

Series SY3000 Series SY5000


ARBY3000 05 P 2 ARBY5000 00 P 2
Pressure gauge connection port Regulating port Pressure gauge connection port Regulating port
05 Pressure gauge (G15-10-01) P P port 00 Pressure gauge (G15-10-01) P P port
M1 Plug (M-5P) A1 A port (P controlled type, A port regulation) M1 Plug (M-5P) A1 A port (P controlled type, A port regulation)
Note) In the case of mounting an B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)
ARBY3000 with a pressure
gauge onto a manifold, use
caution that the part numbers are
different between the odd no.
stations and the even no. stations
to avoid the gauges from
interfering with each other.
ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2
(For odd number stations) (For even number stations)

– – –
+ + +

– –
+ +

Series SY7000
ARBY7000 00 P 2
Pressure gauge connection port Regulating port
00 Pressure gauge (G15-10-01) P P port
M1 Plug (M-5P) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation)

ARBY7000-00--2 ARBY7000-M1--2

Accessory
Series Round head combination screw Gasket
SY3000-23-10
ARBY3000 (M2336) SX3000-57-4
M3 x 48.5,
ARBY5000 Matt nickel plated SX5000-57-6
M4 x 57,

+

+ ARBY7000 Matt nickel plated SX7000-57-4

Caution
Mounting screw
tightening torques
M2: 0.16 N·m
M3: 0.8 N·m
M4: 1.4 N·m

111
SY9000 Base Mounted Type 43 43P Type

Base Mounted Manifold Exploded View

r
u e
U side
∗ Included only withthe
DIN rail mounting type
(with DIN rail).

i

+

t

!1
+


+


+

w
DIN rail holding screw
∗ Not included for direct
mount type.

y
Replacement Parts
No. Description No. Note
SY9000-50-2A-C8 C8: A, B port with one-touch fitting for ø8 !0 o D side
SY9000-50-2A-C10 C10: A, B port with one-touch fitting for ø10
SY9000-50-2A-C12 C12: A, B port with one-touch fitting for ø12
!2
1 Manifold block
SY9000-50-2A-N9 N9: A, B port with one-touch fitting for ø 5 16"
assembly !1 How to assemble lead wire cover
SY9000-50-2A-N11 N11: A, B port with one-touch fitting for ø3 8" Lead wire cover is only usable for double solenoid valves. Lead wire is
SY9000-50-2A-02∗ 02: A, B port 1 4 (∗ thread type) inserted into the lead wire cover as magnifying figure, then push it until it
touches the valve body.
SY9000-50-2A-03∗ 03: A, B port 3 8 (∗ thread type)
4 Round head combination screw SY9000-18-2 M3 x 42, Matt nickel plated
5 Gasket SY9000-11-2
at the end of part number corresponds with the
6 Tension bolt SY9000-23- number of manifold station. Specify the same
number as the number of stations.
Lead wire
7 Hexagon nut SY9000-25-1
Cover
8 DIN rail VZ1000-11-4- Refer to page 110.
at the end of part number corresponds with the

Caution
9 Wiring unit assembly SY9000-36-A number of manifold station. Specify the same
number as the number of stations (4 to 12 stations)
10 Connecter assembly SY9000-37- Refer to page 104. For type 43P (Flat cable manifold) of Series SY9000, the lead wire cover is
11 Lead wire cover SY9000-41-1 attached for bundling the lead wires for each solenoid. In case such as adding
12 Clamp sub assembly SY9000-30-1A Included only with the DIN rail mounting type. double solenoid valve, etc., order separately lead wire cover as well.

w SUP/EXH block assembly no. (D side mounting) e SUP/EXH block assembly no. (U side mounting)

• Direct mount type: SY9000-70- A- • Direct mount type: SY9000-71- A-


• DIN rail mount type: SY9000-72- A- • DIN rail mount type: SY9000-73- A-
P, R port P, R port
C12 One-touch fitting for ø12 C12 One-touch fitting for ø12
N11 One-touch fitting for ø3 8" N11 One-touch fitting for ø 3 8"
00 Plug 00 Plug
Specifications Specifications
1 Internal pilot type 1 Internal pilot type
3 External pilot type 3 External pilot type
4 Internal pilot / Built-in silencer type 4 Internal pilot / Built-in silencer type
5 External pilot / Built-in silencer type 5 External pilot / Built-in silencer type

112
Type 43 43P Base Mounted
Type

How to Increase Manifold Bases (Series SY9000 only)Manifold case can be added at any location.
When a type 43 manifold base is added, tension bolts as well as manifold block assembly will be required. Order the tension bolt suitable for the
stations after a station was increased (decreased), since the length of a tension bolt differs by the number of stations. (For changing the number
of stations for a type 43P manifold, wiring unit for the stations and lead assembly will be required.)

1 Loosen the tension bolts connecting the manifold base, and pull out both of 2 tension bolts.

(When equipped with a DIN rail, loosen one DIN rail holding screw on either U side or D side.)

2 Separate the blocks at the location where station expansion is desired.

3 Mount additional manifold block assembly.

4 Press block-to-block so that there’s no gap. After connection, insert a tension bold for desired stations and then tighten it.
Caution (Tightening torque: 2.9 N·m)
(When equipped with a DIN rail, be sure to tighten the DIN rail holding screws after tightening the tension bolts. Tightening torque: 1.4 N·m)

Caution
1. Be sure to shut off the power and air supplies before disassembly. Furthermore, since air may remain inside the actuator, piping and
manifold, confirm that the air is completely exhausted before performing any work.
2. When disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end block’s
holding screw, is inadequate.
3. By adding wiring unit assembly to type 43 manifold, it can be changed to type 43P manifold, too.

How to Replace A, B Port Fitting Assembly


By replacing manifold block fitting assemblies or the threaded port block assembly of a type 43(P) manifold, the port size of the A and B ports can
be changed. To replace these parts, remove the clip with a flat head screwdriver after the valve has been removed. Insert the fitting assemblies or
threaded port block assembly, and then reinsert the clip so that it does not protrude from the manifold block.

Clip

Thread type port block assembly

Fitting assembly

O-ring

Fitting Assembly Part No.


Port size No. Note
One-touch fitting assembly for ø8 VVQ4000-50B-C8
One-touch fitting assembly for ø10 VVQ4000-50B-C10
One-touch fitting assembly for ø12 VVQ4000-50B-C12
One-touch fitting for ø 5 16" VVQ4000-50B-N9
One-touch fitting for ø 3 8" VVQ4000-50B-N11
1 4 threaded type port block assembly SY9000-58A-02∗ –∗ at the end of part number denotes the thread type.
3 8 threaded type port block assembly SY9000-58A-03∗ –∗ at the end of part number denotes the thread type.
Plug assembly SY9000-62-1A
Note 1) Be careful to avoid damage or contamination of O-rings, as this can cause air leakage.
Note 2) Although replacing the One-touch fittings of P, R port is possible, use caution in the case where solenoid valves are
used at the same time when using the smaller sized fittings than the standard size (ø12). Because they may not be
able to supply or exhaust air sufficiently in comparison to the valve performance. Also, although the fittings used for A,
B port are the same as for P, R port, it is not possible to use the threaded type port block assembly.

113
114
5 Port Solenoid Valve
Series SY3000/5000
Base Mounted
Stacking Type/DIN Rail Mounted
Type 45 Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 3 45 05 U C6 -Q Example

Series Valve stations Double solenoid (24 VDC)


SY3240-5G-Q(2set)
3 SY3000 02 2 stations
5 SY5000 Single solenoid (24 VDC)
...

...

20 20 stations SY3140-5G-Q(2set)
Blanking plate assembly
SUP/EXH block assembly mounting position SX3000-75-1A-Q
Symbol Mounting position Applicable no. of stations Cylinder port size
U U side C6: With one-touch fitting for ø6
2 to 10 stations
D D side
Manifold base (5 stations)
B (Both sides) 2 to 20 stations SS5Y3-45-05D-C6-Q
M∗ Special specifications U
∗ For special specifications, indicate separately
sid
e
by the manifold specification sheet. Sta
tio
ns
A, B port size
3
One-touch fitting (Metric size) One-touch fitting (Inch size) 2
Symbol Port size Applicable series Symbol Port size Applicable series 1 D
sid
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32" e
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
M Mixed M Mixed
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" SS5Y3-45-05D-C6-Q 1 set (Type 45, 5 station manifold base part no.)
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16" ∗ SX3000-75-1A-Q 1 set (Blanking plate assembly part no.)
M Mixed M Mixed ∗ SY3140-5G-Q 2 sets (Single solenoid part no.)
∗ In the case of mixed specifications (M), indicate separately on the ∗ SY3240-5G-Q 2 sets (Double solenoid part no.)
manifold specification sheet.
Option
The asterisk denotes the symbol for assembly.
When a longer DIN rail is desired than the
Prefix it to the part nos. of the solenoid valve, etc.
specified stations, specify the station number
to be required. (20 stations at maximum) The valve arrangement is numbered as the 1st. station from D side regardless of
the mounting position of SUP/EXH block assembly. In ordering, specify the part
nos. in the order from the 1st. station on D side. Besides, when the arrangement
For external pilot specifications and built-in silencer, will be complicated, fill out the manifold specification sheet to instruct us.
refer to page 205.

115
SY3000/5000 Base Mounted Type 45
How to Order Valve

SY 5 2 40 5 L -Q

Series Manual override


3 SY3000 - Non-locking push type
5 SY5000 D Push-turn locking slotted type
E Push-turn locking lever type

Light/surge voltage suppressor


Type of actuation Electrical entry for G, H, L, M, W
1 2 position single - Without light/surge voltage suppressor
2 2 position double S With surge voltage suppressor
3 3 position closed center Z With indicator light and surge voltage suppressor
4 3 position exhaust center R With surge voltage suppressor (Non-polar type)
5 3 position pressure center U With light/surge voltage suppressor (Non-polar type)
∗ Power saving circuit is only available in the "Z" type.
Coil specifications
- Standard
With power saving circuit
T
(24, 12 VDC only)
∗ Power saving circuit is not available in Electrical entry for D (SY5000 only)
the case of D, DO or W type.
- Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Rated voltage Z With light/surge voltage suppressor (Non-polar type)
∗ DOZ is not available.
For DC
∗ For AC voltage valves there is no “S” option. It is
5 24 VDC already built-in to the rectifier circuit.
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry
AC ( Hz) 50 60 24, 12 VDC/
1 100 VAC 24, 12, 6, 5, 3 VDC 100, 110, 200, 24, 12, 6, 5, 3 VDC
2 200 VAC 220 VAC
3 110 VAC [115 VAC] Grommet L plug connector M plug connector DIN terminal M8 connector ∗
4 220 VAC [230 VAC] G: Lead wire L: With lead wire M: With lead wire (SY5000 only) WO: Without
length 300 mm (Length 300 mm) (Length 300 mm) D: With connector connector cable
∗ DC specifications of
H: Lead wire LN: Without lead wire MN: Without lead wire DO: Without W: With connector
type D and DO is only
length 600 mm LO: Without connector MO: Without connector connector cable Note 1)
available with 12 and
24 VDC. ∗ LN, MN type: with 2 sockets.
∗ AC specification is ∗ D and DO only available for SY5000.
only available with D ∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available.
and DO type. For details, refer to page 210.
∗ D and DO only ∗ For connector cable of M8 connector, refer to back page 12.
available for SY5000. ∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back page 13.

116
Type 45 Base Mounted
Manifold Specifications

Model SS5Y3-45 SS5Y5-45


Applicable valve SY340 SY540
Manifold type Stacking type/DIN rail mounted
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations Note 1)
A, B port Location Base
Porting specifications Direction Side
P, R port C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10)
C4 (One-touch fitting for ø4)
Port size C4 (One-touch fitting for ø4)
A, B port C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6)
C8 (One-touch fitting for ø8)
Manifold base weight 2 to 10 stations: W = 22n + 118 2 to 10 stations: W = 47n + 156
W (g), n: Stations 11 to 20 stations: W = 22n + 140 11 to 20 stations: W = 47n + 190
Note 1) For more than 11 stations, supply pressure to P port on both sides and exhaust from R port
on both sides.

Flow Characteristics

Port size Flow characteristics


Model 1 ,5 ,3 4 ,2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P ,EA ,EB) (A ,B) C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]* C (dm3/ (s·bar) ) b Cv Q[l/min(ANR)]*
SS5Y3-45 C8 C6 0.88 0.21 0.22 212 0.95 0.18 0.22 225
SS5Y5-45 C10 C8 2.2 0.24 0.53 539 2.5 0.18 0.58 592
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

117
SY3000/5000 Base Mounted Type 45
Manifold Option
 Individual SUP spacer assembly  Individual EXH spacer assembly  SUP blocking disk  EXH blocking disk
By installing a SUP blocking disk in By installing an EXH blocking disk in the
the pressure supply passage of a exhaust passage of a manifold valve, it
manifold valve, it is possible to is possible to divide the valve’s exhaust
supply two or more different high and so that it does not affect another valve.
low pressures to one manifold. (Two blocking disks are needed to divide
both exhausts.)
End plate

Series No. Series No.


t t SY3000
SY3000 SX3000-77-1A SX3000-77-1A
SY5000 SX5000-77-1A SY5000 SX5000-77-1A
SUP port EXH port
 Label for block disk
The labels shown below are used on manifold stations containing
SUP/EXH blocking disk(s) to show their location. (3 pcs. each)
Series Assembly part no. Port size t Series Assembly part no. Port size t
SY3000 SY3000-39-2A-Q
VZ3000-123-1A
SY3000 SY3000-38-2A-Q M5 11 M5 11
SY5000 SY5000-39-16∗A-Q Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
SY5000 SY5000-38-16∗A-Q 18 15 18 15
Note) The SUP port may be Note) The EXH port may be
either on the lead wire either on the lead wire
side or on the end side or on the end
plate side. plate side.

 Blanking plate assembly ∗ Thread type Note) When a block disk is concurrently ordered by specifying on
- Rc the manifold specification sheet, etc., a label will be stuck
F on the position where block disk is mounted.
G
N NPT  Silencer with One-touch fitting
T NPTF The silencer plugs directly into the One-touch fittings of the
manifold.
C
B
Caution
Mounting screw
A

tightening torques
Series Assembly part no. M2: 0.16 N·m
SY3000 SX3000-75-1A-Q M3: 0.8 N·m Series Model Effective area A B C
SY5000 SX5000-76-5A-Q M4: 1.4 N·m For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
AN200-KM10 26 mm2 ø22 53.8 80.8
For SY5000 (ø10)
AN300-KM10 30 mm2 ø25 70 97
 Dimensions/DIN rail
VZ1000 11 1
Refer to L dimensions
 Plug (white)
These are inserted in unused cylinder ports and SUP, EXH ports.
∗ Fill in  with an appropriate no. listed on the table of
DIN rail dimensions shown below. Purchasing order is available in units of 10 pieces.
ød

L
øD

A
L
Dimensions
No. 0 1 2 3 4 5 6 7 8 9 10 Applicable fittings size ød Model A L D
L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 4 KQ2P-04 16 32 6
6 KQ2P-06 18 35 8
No. 11 12 13 14 15 16 17 18 19 20 21
8 KQ2P-08 20.5 39 10
L Dimension 235.5 248 260.5 273 285.5 298 310.5 323 335.5 348 360.5
10 KQ2P-10 22 43 12
No. 22 23 24 25 26 27 28 29 30 31 32 1 8" KQ2P-01 16 31.5 5
L Dimension 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 5 32" KQ2P-03 16 32 6
No. 33 34 35 36 37 38 39 40 41 42 43 1 4" KQ2P-07 18 35 8.5
L Dimension 510.5 523 535.5 548 560.5 573 585.5 598 610.5 623 635.5 5 16" KQ2P-09 20.5 39 10
No. 44 45 46 47 48 49 50 51 52 53 54
L Dimension 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773
No. 55 56 57 58 59 60 61 62 63 64 65
L Dimension 785.5 798 810.5 823 835.5 848 860.5 873 885.5 898 910.5
No. 66 67 68 69 70 71
L Dimension 923 935.5 948 960.5 973 985.5
∗ Refer to L1 dimension on pages starting with page 121 for lengths
that correspond to the number of manifold stations.

118
Type 45 Base Mounted

Manifold Option

 How to Order Interface Regulator (SY3000, 5000 only)

Series SY3000 Series SY5000


ARBY3000 05 P 2 ARBY5000 00 P 2
Regulating port Regulating port
P P port P P port
A1 A port (P controlled type, A port regulation) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)

Pressure gauge connection port Pressure gauge connection port


05 Pressure gauge (G15-10-01) [for odd number station] 00 Pressure gauge (G15-10-01)
06 Pressure gauge (G15-10-01) [for even number station] M1 Plug (M-5P)
M1 Plug (M-5P)
∗ In the case of mounting an ARBY3000
with a pressure gauge onto a
manifold, use caution that the part
numbers are different between the
odd no. stations and the even no.
stations to avoid gauges interfering
with each others.

ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2


(For mounting odd (For mounting even
number stations) number stations)

–+ –+ –+

–+ –+

Accessory Caution
Series Round head combination screw Gasket Mounting screw
ARBY3000 SY3000-23-10
(M2 x 36) SX3000-57-4 tightening torques
M3 x 48.5,
ARBY5000 Matt nickel plated SX5000-57-6 M2: 0.17 N·m
M3: 0.8 N·m

119
120
Type 45 Base Mounted
Dimensions: Series SY3000
SS5Y3-45- Stations D- C4, N3
C6, N7 -Q SS5Y3-45- Stations U- C4, N3
C6, N7 -Q
(Station n) (Station 1)

(Light/surge voltage suppressor)

(Lead wire length)


Manual override

Approx. 300
-+ -+ -+ -+ -+

(C6: 3.2)
(N7: 7)
63.3
47.9

34.5

(3)
Block separation button

7.5
8

37.2
28.7

34
(Push type)
B B B B B

97.3

5.5
(Lead wire length)

35

88.8
Approx. 300

(C6: 3.2)

15.7
A A A A A
(N7: 7)

37.9

33
Manual override
(3)

DIN rail
L3 (L4)
8
37.2
28.7

DIN rail holding screw


34

L2 5
97.3

B B B B B
5.5

88.8
35

(Rail mounting hole pitch: 12.5)


A A A A A
L1
37.9

33
15.7

(Pitch)
Button for DIN rail release 24.8 13.5 P=10.5 21.7

11.2
DIN rail (L4)
L3
DIN rail L2 5
R A A A A A

22.2
25.2

holding screw (Rail mounting hole pitch: 12.5)


10.2

L1 B B B B B
P
(Pitch) Button for DIN
P=10.5 13.5 24.8 rail release One-touch fitting One-touch fitting
11.2

P, R port A, B port
-+ -+

Applicable tubing O.D.: ø8, ø5/16" Applicable tubing O.D.


22.2

A A A A A R
25.2
10.2

(Light/surge voltage suppressor) : ø4, ø5/32"


B B B B B
P : ø6, ø1/4"
One-touch fitting One-touch fitting
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(A, B port) (P, R port)
-+ -+

Applicable tubing O.D.: ø4, ø5/32" Applicable tubing L1 98 110.5 123 135.5 148 148 160.5 173 185.5
: ø6, ø1/4" O.D.: ø8, ø5/16" L2 87.5 100 112.5 125 137.5 137.5 150 162.5 175
L3 70.5 81 91.5 102 112.5 123 133.5 144 154.5
L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5

With interface regulator (with gauge)

78.3 (Pitch)
P=10.5 13.5 24.8
42.3

34.5
(64)
34

B B B
35

A A A
33
77
90.5

77.8
ø15

121
SY3000/5000 Base Mounted Type 45
Dimensions: Series SY3000
SS5Y3-45- Stations B- C4, N3
C6, N7 -Q
(Lead wire length)
Approx. 300

L plug connector

(C6: 3.2)
(N7: 7)
Manual override

(Lead wire length)


Approx. 300
(3)

63.3
47.9
8
37.2
28.7

34
B B B B B
97.3

5.5

88.8
35

15.7
A A A A A
37.9

33
DIN rail L3 (L4)

117.1
108.6
DIN rail L2 5
holding screw (Rail mounting hole pitch: 12.5)
L1

47.8
(Pitch)
Button for DIN rail release 24.8 P = 10.5 13.5 24.8
10.2

R A A A A A R
22.2

25.2
11.2

P
B B B B B
P
M plug connector
One-touch fitting One-touch fitting
(A, B port) -+ -+
(P, R port)
Applicable tubing O.D. : ø4,ø5/32" Applicable tubing O.D.: ø8, ø5/16" Approx. 300 74.4
: ø6, ø1/4" (Lead wire length)
(Light/surge voltage suppressor)
97.5
89

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


L1 110.5
38

123 135.5 148 160.5 173 185.5 185.5 198


L2 100 112.5 125 137.5 150 162.5 175 175 187.5
L3 87 97.5 108 118.5 129 139.5 150 160.5 171
L4 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5
Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
L1 210.5 223 235.5 248 248 260.5 273 285.5 298 310.5
L2 200 212.5 225 237.5 237.5 250 262.5 275 287.5 300 M8 connector (WO)
L3 181.5 192 202.5 213 223.5 234 244.5 255 265.5 276
M8 x 1
L4 14.5 15.5 16.5 17.5 12 13 14 15 16 17
100.5

115.3
106.8
92

80.8
39.5

50.3
67.8

Note) Refer to back page 12 for


dimensions of connector types.

122
Type 45 Base Mounted
Dimensions: Series SY5000
C4, N3 C4, N3
SS5Y5-45- Stations D- C6, N7 -Q SS5Y5-45- Stations U- C6, N7 -Q
C8, N9 C8, N9

(Lead wire length)


Manual override

119.8 [124.2] Approx. 300


(Station n) (Station 1)
(Light/surge voltage suppressor)

(4.9)
DIN rail

(3.5)
71.1 [78.1]

–+ –+ –+ –+ –+

107.2 [111.6]
44.2
(For DIN
8

53.4 [55.6] 41.2


55.7

31.2 31.6
: 45.5)

(For DIN (For DIN


42.7
B B B B B

: 32.5) : 32.9)

5.5
35

48.3
A A A A A

7.5
Block separation button
(Push type)
(Lead wire length)

Manual override DIN rail


119.8 [124.2] Approx. 300

holding screw
L3 (L4)
DIN rail holding screw
(4.9)

(3.5) DIN rail L2 5


(Rail mounting hole pitch: 12.5)
L1
44.2

8
(For DIN

53.4 [55.6] 41.2


107.2 [111.6]
(Pitch)
31.2 31.6
: 45.5)

(For DIN (For DIN

B B B B B
: 32.5) : 32.9)

Button for DIN rail release 26 17 P=16 25


35
5.5

14.5

15.5
31.5
A A A A A

32
48.3

R A A A A A

P B B B B B

One-touch fitting
One-touch fitting
L3 (L4) P, R port
–+ –+

Applicable tubing O.D.: ø10, ø3/8"


A, B port
L2 5 Applicable tubing O.D.: ø4, ø5/32"
(Rail mounting hole pitch: 12.5) (Light/surge voltage suppressor) ø6, ø1/4"
L1 ø8, ø5/16"
(Pitch)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
14.5

Button for DIN rail release P=16 17 26


L1 110.5 135.5 148 160.5 173 198 210.5 223 235.5
L2 100 125 137.5 150 162.5 187.5 200 212.5 225
31.5
15.5

32

A A A A A R
L3 84 100 116 132 148 164 180 196 212
B B B B B P L4 13 17.5 16 14 12.5 17 15 13.5 11.5
One-touch fitting
One-touch fitting
(P, R port)
–+ –+

(A, B port)
Applicable tubing O.D.:
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4" ø10, ø3/8"
ø8, ø5/16"

With interface regulator (with gauge)

(Pitch)
54.5 P=16 17 26
(87.2)
41.2

B B B
35

48.3

A A A
69.8

ø15 42.7
94.1 [101.1]

123
SY3000/5000 Base Mounted Type 45
Dimensions: Series SY5000
C4, N3
SS5Y3-45- Stations B-C6, N7 -Q
C8, N9
(Lead wire length)
Approx. 300

Manual override DIN rail holding screw


L plug connector

(4.9)
DIN rail
(3.5)

71.1

(Lead wire length)


8 55.7
44.2

Approx. 300
41.2
(For DIN

31.2 31.6
(For DIN: (For DIN:
: 45.5)

B B B B B
119.8

32.9)

107.2
35
5.5

48.3
A A A A A

53.4
32.5)

139.6
L3 (L4)

127
L2 5
(Rail mounting hole pitch: 12.5)
L1

63.3
(Pitch)
Button for DIN rail release 26 P=16 17 26
14.5
31.5
15.5

32

R A A A A A R

P B B B B B P
One-touch fitting
One-touch fitting
(P, R port)
–+ –+

(A, B port) Applicable tubing O.D.: ø10, ø3/8" M plug connector


Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4" (Light/surge voltage suppressor)
ø8, ø5/16"
Approx. 300 82.2 [89.2]
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(Lead wire length)
L1 135.5 148 160.5 185.5 198 210.5 223 248 260.5
L2 125 137.5 150 175 187.5 200 212.5 237.5 250
L3 102 118 134 150 166 182 198 214 230
L4 16.5 15 13 17.5 16 14 12.5 17 15
120
107.4

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations


L1 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423
L2 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5
53.5

L3 246 262 278 294 310 326 342 358 374 390
L4 13.5 11.5 16 14.5 12.5 17 15.5 13.5 12 16.5

M8 connector (WO) DIN terminal (D)

Applicable cable O.D. 103.9


ø3.5 to ø7 96.4
Pg7 85.1
137.8

157.8
123
110.4

125.2

145.2

159.6
147
103.6
55

72.4

73.3

58.1
M8 x 1 75.6
Max. 10

Note) Refer to back page 12 for


dimensions of connector types.

124
Type 45 Base Mounted
DIN Rail Manifold Exploded View
Type 45
r
U side t
c n
ail tto
N r bu
DI ease w
rel


+ y

q

+

+

w
a DIN rail holding screw

e
c n
ail tto
N r bu
DI ease
rel
b Block separation button
C
SM
D side

u
Replacement Parts
No.
No. Description Note
SY3000 SY5000
: SY3000 (Metric size) C4: With one-touch fitting for ø4 (Inch size) N3: With one-touch fitting for ø 5 32"
C6: With one-touch fitting for ø6 N7: With one-touch fitting for ø 1 4"
1 Manifold block SY5000 (Metric size) C4: With one-touch fitting for ø4 (Inch size) N3: With one-touch fitting for ø 5 32"
assembly SX3000-50-1A--Q SX5000-50-1A--Q
C6: With one-touch fitting for ø6 N7: With one-touch fitting for ø 1 4"
C8: With one-touch fitting for ø8 N9: With one-touch fitting for ø 5 16"
(Gasket 6 is supplied as an accessory.)
(Metric size) (Metric size) P, R port SY3000 (Metric size) With one-touch fitting for ø8
2 SUP/EXH block SX3000-51-1A SX5000-51-1A (Inch size) With one-touch fitting for ø5 16"
assembly (Inch size) (Inch size) P, R port SY5000 (Metric size) With one-touch fitting for ø10
SX3000-51-15A SX5000-51-15A (Inch size) With one-touch fitting for ø3 8"
3 End block assembly R SX3000-52-1A-Q SX5000-52-1A-Q For D side
4 End block assembly R SX3000-53-1A-Q SX5000-53-1A-Q For U side
5 Round head SY3000-23-4 M3 x 26
combination screw (Matt nickel plated)
6 Gasket SX3000-57-4 SX5000-57-6
7 DIN rail VZ1000-11-1- Refer to page 118.

125
SY3000/5000 Base Mounted Type 45
DIN Rail Manifold Exploded View

How to Increase Manifold Bases Station expansion is possible at any position. How to Change
. Fitting Assembly
1 Loosen DIN rail holding screw a fixing the manifold base until it Clip Type 45 manifold permits
begins to turn idly. (While pressing DIN rail releasing buttons c , change in the A and B port
at two locations, separate the manifold base from the DIN rail.) sizes by changing the
2 Press manifold block assembly dividing button b , that are at the manifold block fitting
location where manifold bases are to be added, until button b assembly.
locks, and then separate the block assemblies. After removing the valve,
remove the clip with a
3 Mount additional manifold block assembly on the DIN rail as
Fitting assembly screwdriver, etc. For
shown in the figure 1. mounting a new fitting
4 Press the block assemblies until a click sound is produced, and assembly, insert it and then
tighten the DIN rail holding screw a to fix them to the DIN rail. insert a clip until it will not
Caution (Tightening torque: 1.4 N·m) come out of the manifold
(While lightly holding the blocks after fixing an end block on one block.
side, tighten the other end block for for better sealing.) O-ring

Caution Fitting Assembly Part No.


Note 1) When there are 10 or fewer manifold block
Metric size
assemblies, and more are added to make a total of
11 or more, a supply/exhaust block assembly must One-touch fitting for ø4 VVQ1000-50A-C4
SY3000
also be added. One-touch fitting for ø6 VVQ1000-50A-C6
Note 2) When disassembly and assembly are performed, One-touch fitting for ø4 VVQ1000-51A-C4
air leakage may result if connections between SY5000 One-touch fitting for ø6 VVQ1000-51A-C6
blocks and tightening of the end block’s holding
One-touch fitting for ø8 VVQ1000-51A-C8
screw, is inadequate. Before supplying air, confirm
that there are no gaps, etc. between blocks, and Inch size
that manifold blocks are securely fastened to the One-touch fitting for ø 5 32" VVQ1000-50A-N3
DIN rail. Then supply air and confirm that there is SY3000
One-touch fitting for ø 1 4" VVQ1000-50A-N7
no air leakage before operating.
One-touch fitting for ø 5 32" VVQ1000-51A-N3
Fig. (1) Block mounting procedure SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø 5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust.
Otherwise, air leakage may result.

Hook the DIN rail here and press down in


the direction of the arrow until a click
sound is heard.

126
5 Port Solenoid Valve
Series SY3000/5000
Base Mounted
Stacking Type/DIN Rail Mounted
Type 45-ANA Connector Box
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 3 45 A U 05 D C6 -Q Example (SY3000, +COM, U side)


Double solenoid (24 VDC)

Series SY3240-5LOU-Q (2 sets)


Single solenoid (24 VDC)
3 SY3000
SY3140-5LOU-Q (2 sets)
5 SY5000 +-

CO
SM
C
Cylinder port size
BO NNEC

C6: With one-touch fitting for ø6


X TO

Specifications
R

24
DC V 14
+
15

Manifold base
- 6

Symbol Specifications
7

A With connector box (+COM spec.)


- +

- +
SS5Y3-45-AU-05D-C6-Q
NA With connector box (–COM spec.)
- +

- +

U
The style of attached lead sid
e
wire assembly is different. Sta
tion
s ....
32
Connector box mounting position Blanking plate assembly 1
Symbol Mounting position SX3000-75-1A-Q D
sDid
U U side e
D D side SS5Y3-45-AU-05D-C6-Q 1 set (Type 45, 5 station manifold base part no.)
∗ SX3000-75-1A-Q 1 set (Blanking plate assembly part no)
Valve stations ∗ SY3140-5LOU-Q 2 sets (Single solenoid part no.)
Symbol Stations Note ∗ SY3240-5LOU-Q 2 sets (Double solenoid part no.)
02 2 stations Applicable up to The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
16 solenoid
...

...

16 16 stations valves. The valve arrangement is numbered as the 1st. station from D side
regardless of the mounting position of connector box. In ordering, specify the
SUP/EXH block assembly mounting position part nos. in the order from the 1st. station on D side. Besides, when the
arrangement will be complicated, fill out the manifold specification sheet to
Symbol Mounting position Applicable stations
instruct us.
U U side SS5Y 35 -45-A UD --C is assembled with solenoid valve and lead wire
2 to 10 stations
D D side assembly when shipping. When ordering manifold only (without
B Both sides 2 to 16 stations valves/wires/options), refer to how to order on page 115 and list the
M∗ Special specifications connector box (VZ3000-106-1A) and the rail stopper (TXE1-SMC) below the
∗ For special specifications, indicate separately manifold to allow for the connector box mounting at U side. (Be sure to order
by the manifold specification sheet. DIN rail 3 station longer than number of the manifold stations.) In this case,
please note that dimensions, L1 and L2 on pages 131 and 132 may vary
A/B port size slightly.) For other components, refer to page 133.

One-touch fitting (Metric size) One-touch fitting (Inch size)


Symbol Port size Applicable
. series Symbol Port size Applicable series How to Order Valve
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32"
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1/4" SY3000
M Mixed
C4 One-touch fitting for ø4
M Mixed
N3 One-touch fitting for ø5/32"
SY 5 2 40 5 LOU -Q
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1/4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/32" Series
M Mixed M Mixed
3 SY3000
∗ In the case of mixed specifications, indicate separately on the 5 SY5000
manifold specification sheet. Manual override
Option
- Non-locking push type
When a longer DIN rail is desired than the specified stations, Type of actuation D Push-turn locking slotted type
specify the station number to be required.
(Max. 20 stations) 1 2 position single E Push-turn locking lever type
2 2 position double
For external pilot specifications and built-in silencer, 3 3 position closed center
refer to page 205. 4 3 position exhaust center
5 3 position pressure center

Rated voltage
5 24 VDC

127
SY3000/5000 Base Mounted Type 45-ANA
Manifold Specifications

Model SS5Y3-45-ANA SS5Y5-45-ANA


Applicable valve SY340 SY540
Manifold type Stacking type/DIN rail mounted
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 16 stations Note 1, 2)
A, B port Location Base
Porting specifications Direction Side
P, R port C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10)
C4 (One-touch fitting for ø4)
Port size C4 (One-touch fitting for ø4)
A, B port C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6)
C8 (One-touch fitting for ø8)
Manifold base weight W (g) 2 to 10 stations: W = 26n + 207 2 to 10 stations: W = 52n + 245
n: Stations 11 to 20 stations: W = 26n + 229 11 to 16 stations: W = 52n + 279
Applicable flat ribbon cable Flat ribbon cable connector Socket: 20 pins MIL type
connector with strain relief conforming to MIL-C-83503
Wiring specifications +COM specifications (Type 45-A), –COM specifications (Type 45-NA)
Note 1) For more than 11 stations, supply pressure to P port on both sides and exhaust from R port
on both sides.
Note 2) There is a limit depending on the number of solenoids. Refer to “How to Order”.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
SS5Y3-45- C8 C6 0.88 0.21 0.22 212 0.95 0.18 0.22 225
SS5Y5-45- C10 C8 2.2 0.24 0.53 539 2.5 0.18 0.58 592
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard
conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.

Manifold Wiring Diagram (Circuit diagram for the reference layout)

+COM electric circuit diagram –COM electric circuit diagram


Connector box Connector box
(Wiring example) (Wiring example)

Station 1 Station 1

Station 2 Station 2

Station 3 Station 3

Station 4 Station 4
Triangle mark Triangle mark

Station 5 Station 5

24 VDC 24 VDC
Power supply terminal Power supply terminal

SoL. B -+

Reference layout -+

• Connector box for +COM allows transmission until G71-OD16, manufactured 0

1
8

by OMRON Corp., to be connected directly for serial transmission. Additionally, 2 10 B B B B B


3 11

it can also be used for the PC wiring system.


U side D side
4 12

• When an external power source must be supplied to the manifold, correct 5

6
13

14
A A A A A
CONNECTOR

polarity must be observed, otherwise damage to PLC is possible.


BOX
VZ3000-106-1A
7 15

• The wiring of solenoid valves, corresponds with the labeled connector box 0 to
15 from D side. -+ -+ -+ -+ -+

• If valves other than non-polar type are used, this may cause malfunction. SoL. A SoL. A
(Station 2)
(Station n)

(Station 1)

......

128
Type 45-ANA Base Mounted
Manifold Option
 Individual SUP spacer assembly  Individual EXH spacer assembly  SUP blocking disk  EXH blocking disk
By installing a SUP blocking disk in By installing an EXH blocking disk
the pressure supply passage of a in the exhaust passage of a
manifold valve, it is possible to manifold valve, it is possible to
supply two or more different high divide the valve’s exhaust so that
and low pressures to one manifold. it does not affect another valve.
(Two blocking disks are needed to
End plate End plate divide both exhausts.)

t
t
Series Part no. Series Part no.
SUP port
SY3000 SX3000-77-1A SY3000 SX3000-77-1A
SY5000 SX5000-77-1A SY5000 SX5000-77-1A
EXH port
 Label for block disk
The labels shown below are used on manifold stations containing
Series Assembly part no. Port size t Series Assembly part no. Port size t SUP/EXH blocking disk(s) to show their location. (3 pcs. each)
SY3000 SY3000-38-2A-Q M5 11 SY3000 SY3000-39-2A-Q M5 11
SY5000 SY5000-38-16∗A-Q 18 15 SY5000 SY5000-39-16∗A-Q 18 15
VZ3000-123-1A
Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
Note) The SUP port may be either Note) The EXH port may be either
on the lead wire side or on the on the lead wire side or on
end plate side. (An assembly the end plate side. (An
is shipped under the condition assembly is shipped under
shown in the figure.) the condition shown in the
figure.)
 Blanking plate assembly ∗ Thread type Note) When a block disk is concurrently ordered by specifying on the
- Rc manifold specification sheet, etc., a label will be stuck on the
F position where block disk is mounted.
G
N NPT  Silencer with One-touch fitting
T NPTF
The silencer plugs directly into the One-touch fittings of the manifold.

Caution
Mounting screw
tightening torques
Series Assembly part no.
SY3000 SX3000-75-1A-Q
M2: 0.16 N·m Series Model Effective area A B C
SY5000 SX5000-76-5A-Q
M3: 0.8 N·m For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
M4: 1.4 N·m AN200-KM10 26 mm2 ø22 53.8 80.8
For SY5000 (ø10)
 Cable assembly AN300-KM10 30 mm2 ø25 70 97
1
AXT100-FC20- |
3  Plug (white)
Red
These are inserted in unused cylinder ports and SUP, EXH ports.
Purchasing order is available in units of 10 pieces.

Terminal
number
Dimensions
Applicable fittings size ød Model A L D
Connector Assembly for Flat Ribbon Cables 4 KQ2P-04 16 32 6
6 KQ2P-06 18 35 8
Cable length (L) Assembly part no. Note
8 KQ2P-08 20.5 39 10
1.5 m AXT100-FC20-1
Cable 20 core 10 KQ2P-10 22 43 12
3m AXT100-FC20-2
x 22 AWG 1 8" KQ2P-01 16 31.5 5
5m AXT100-FC20-3 5 32" KQ2P-03 16 32 6
∗ For other commercial connectors, use a 20 pins with strain relief
conforming to MIL-C-83503.
1 4" KQ2P-07 18 35 8.5
5 16" KQ2P-09 20.5 39 10

Connector manufacturers’ example


• Sumitomo 3M Limited Warning
• Fujitsu Limited When mounting a valve or spacer on the manifold base or sub-plate, etc., those mounting
• Japan Aviation Electronics Industry, Ltd. directions are determined. If mounted in the wrong direction, the equipment to be connected may
• J.S.T. Mfg. Co., Ltd. cause malfunction. Refer to external dimensions, and then mount it.

129
SY3000/5000 Base Mounted Type 45-ANA
Manifold Option

 How to Order Interface regulator (SY3000, 5000 only)

Series SY3000 Series SY5000


ARBY3000 05 P 2 ARBY5000 00 P 2
Regulating port Regulating port
P P port P P port
A1 A port (P controlled type, A port regulation) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)

Pressure gauge connection port Pressure gauge connection port


05 Pressure gauge (G15-10-01) [for odd number station] 00 Pressure gauge (G15-10-01)
06 Pressure gauge (G15-10-01) [for even number station] M1 Plug (M-5P)
M1 Plug (M-5P)
∗ In the case of mounting an ARBY3000
with a pressure gauge onto a manifold,
use caution that the part numbers are
different between the odd no. stations
and the even no. stations to avoid the
gauges from interfering with each other.

ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2


(For odd number stations) (For even number stations)

- + - + - +

- + - +

Accessory Caution
Series Round head combination screw Gasket Mounting screw tightening torques
SY3000-23-10
ARBY3000 (M2 x 36) SX3000-57-4
M3 x 48.5,
M2: 0.16 N·m
ARBY5000 Matt nickel plated SX5000-57-6 M3: 0.8 N·m

130
Type 45-ANA Base Mounted
Dimensions: Series SY3000
SS5Y3-45-AU- Stations D- C4, N3
C6, N7 -Q
(Light/surge voltage suppressor) (Station n) (Station 1) Block separation button
(Push type)

63.3
58.1

47.9
42.6

34.5
7.5

Applicable connector: 20 pins MIL type


with strain relief 12 41 L3 (L4)
(Conforming to MIL-C-83503) (C6: 3.2)
6

-+
(N7: 7)
4

-+

(3) DIN rail


With interface regulator (with gauge)
8
0 8

78.3
42.5

1 9
37.2

15.7 28.7
117.1

42.3
2 10

34
B B B B B
108.6

5.5

3 11
(Pitch)
35

5
12

13
34.5 P = 10.5 13.5 24.8
A A A A A
CONNECTOR
6 14 33
42.5

BOX

47.8
VZ3000-106-1A
7 15 -+
-+

-+ -+ -+ -+ -+

(63.7)
Manual DIN rail
5

LED for power supply


override holding screw
Power supply terminal

34
B B B

L2 (Rail mounting hole pitch: 12.5) 5

35
L1 A A A

One-touch fitting

33
(Pitch) Button for DIN rail release
A, B port
Applicable tubing O.D.: ø4, ø5/32" P = 10.5 13.5 24.8
10.2
11.2

77
90.5
ø6, ø1/4" -+ -+ -+
22.2

A A A A A R
25.2

B B B B B
P

One-touch fitting
P, R port 77.8 ø15
Applicable tubing O.D.: ø8, ø5/16"

SS5Y3-45-AD- Stations U- C4, N3


C6, N7 -Q
(Light/surge voltage suppressor) (Station n) (Station 1)
0
63.3

58.1
48.4

42.6
34.5

7.5

Block separation button


(Push type) Applicable connector: 20 pins MIL type
L3 41 12 (L4) with strain relief
(Conforming to MIL-C-83503)
LED for power supply
(C6: 3.2)
6

(N7: 7)

-+

Power supply
4

terminal
-+

DIN rail
(3)

8
42.5
37.2

15.7 28.7
117.1

34

B B B B B 15 7
VZ3000-106-1A
108.6

5.5

BOX
CONNECTOR
14 6
35

13 5

A A A A A 12 4

11 3
33

42.5
47.8

10 2

9 1

8 0

-+ -+ -+ -+ -+

DIN rail holding screw Manual


5

override L2 (Rail mounting hole pitch: 12.5) 5


L1
One-touch fitting
A, B port
Button for DIN rail release Applicable tubing O.D.: ø4, ø5/32"
(Pitch) ø6, ø1/4"
11.2
10.2

24.8 13.5 P = 10.5 74.7


Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 stations
L1 148 160.5 173 185.5 198 210.5 210.5 223 235.5 260.5 273 285.5 298 310.5 310.5
22.2

R A A A A A
25.2

L2 137.5 150 162.5 175 187.5 200 200 212.5 225 250 262.5 275 287.5 300 300
L3 70.5 81 91.5 102 112.5 123 133.5 144 154.5 181.5 192 202.5 213 223.5 234
B B B B B
P

One-touch fitting L4 12 13 14 15 16 17 12 13 14 13 14 15 16 17 11.5


P, R port ∗ Two SUP/EXH blocks are provided for models
Applicable tubing O.D.: ø8, ø5/16"
131 with 11 stations or more.
SY3000/5000 Base Mounted Type 45-ANA
Dimensions: Series SY5000
C4, N3
SS5Y5-45-AU- Stations D- C6, N7
C8, N9
(Light/surge voltage suppressor) (Station n) (Station 1)

71.1
58.1

55.7
42.7
42.6

Block separation button

7.5
(Push type)
Applicable connector: 20 pins MIL type
With interface regulator (with gauge)
With strain releaf (Pitch)
(L4) 54.5 P=16 17 26
(Conforming to MIL-C-83503) 12 41 L3
Manual override
6

-+ -+

(3.5)
(4.9) DIN rail
4

-+ -+

(87.2)
0 8
44.2

44.2
42.5

41.2
1 9
31.6

2 10 B B B B B B B B
139.6

5.5

3 11
127

4 12
5 13
35

31.2
6 14
42.5

CONNECTOR
48.3

48.3
BOX 7 15 A A A A A A A A
VZ3000-106-1A
63.3

69.8
-+ -+ -+ -+ -+
DIN rail -+ -+ -+

holding screw
5

LED for power supply


5 ø15 42.7
L2
Power supply terminal (Rail mounting hole pitch: 12.5) 94.1
L1
(Pitch)
P=16 17 26 Button for DIN rail release
One-touch fitting (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
31.5

32

ø8, ø5/16"
14.5

A A A A A R
15.5

B B B B B P
One-touch fitting
P, R port
Applicable tubing O.D.: ø10, ø3/8"
C4, N3
SS5Y5-45-AD- Stations U- C6, N7
C8, N9
(Station n) (Station 1)
(Light/surge voltage suppressor)
0
71.1

58.1
55.7
42.7

42.6
7.5

Block separation button


(Push type)
(L4) L3 41 12
DIN rail Power supply terminal
Manual override
6

-+
(4.9)
4

LED for power supply


(3.5)

-+

8 Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 stations


44.2

42.5
41.2

L1 160.5 185.5 198 210.5 235.5 248 260.5 273 298 323 348 360.5 373 398 410.5
31.2 31.6

B B B B B
139.6

15 7 VZ3000-106-1A

L2 150 175 187.5 200 225 237.5 250 262.5 287.5 312.5 337.5 350 362.5 387.5 400
5.5

BOX
CONNECTOR
14 6
127

13 5

L3 84 100 116 132 148 164 180 196 212 246 262 278 294 310 326
35

12 4
42.5

11 3

L4 11.5 16 14.5 12.5 17 15.5 13.5 12 16.5 12 16.5 14.5 13 17.5 15.5
48.3

A A A A A 10 2
63.3

9 1

8 0
∗ Two SUP/EXH blocks are provided for models
with 11 stations or more.
- + - + - + - + - +

Applicable connector:
5

DIN rail 20 pins MIL type


holding screw L2 5
(Rail mounting hole pitch: 12.5) With strain releaf
L1 (Conforming to MIL-C-83503)
Button for DIN rail release
(Pitch)
14.5

15.5

26 17 P=16 78
31.5
32

R A A A A A

P B B B B B

One-touch fitting
One-touch fitting (A, B port)
P, R port
Applicable tubing O.D.: Applicable tubing O.D.: ø4, ø5/32"
ø10, ø3/8" ø6, ø1/4"
ø8, ø5/16" 132
Type 45-ANA Base Mounted
DIN Rail Manifold Exploded View
Type 45-A
NA
i
U side D Bolts o
y
u
0

8
2
9
3
10
4
11
5
12
24V
6
DC
+ 13
7
14
-
15

t !0

r q DIN rail
a holding screw
w
w
e
e
eas
CN rail rel
DI ton
but

b
C
SM

Block separation button

D side

Replacement Parts !1
No.
No. Description Note
SY3000 SY5000
•SY3000
(Metric size) (Inch size)
C4: With one-touch fitting for ø4 N3: With one-touch fitting for ø 5 32"
C6: With one-touch fitting for ø6 N7: With one-touch fitting for ø 1 4"
Manifold block For SY5000
1 assembly
SX3000-50-1A--Q SX5000-50-1A--Q
(Metric size) (Inch size)
C4: With one-touch fitting for ø4 N3: With one-touch fitting for ø5 32"
C6: With one-touch fitting for ø6 N7: With one-touch fitting for ø 1 4"
C8: With one-touch fitting for ø8 N9: With one-touch fitting for ø 5 16"
(Gasket 10 is supplied as an accessory.)
(Metric size) (Metric size) P, R port SY3000 (Metric size) With one-touch fitting for ø8
SUP/EXH block SX3000-51-1A SX5000-51-1A (Inch size) With one-touch fitting for ø5 16"
2 assembly (Inch size) (Inch size) P, R port SY5000 (Metric size) With one-touch fitting for ø10
SX3000-51-15A SX5000-51-15A (Inch size) With one-touch fitting for ø3 8"
3 End block assembly R SX3000-52-1A-Q SX5000-52-1A-Q For D side
4 End block assembly L SX3000-53-1A-Q SX5000-53-1A-Q For U side
5 Connector box VZ3000-106-1A For 24 VDC only
6 Rail stopper TXE1-SMC Made by Kasuga Electric Works
Type D, 2 to 8 stations
SY3000-43-1A- SY3000-43-2A- +COM Type U, 9 to 16 stations

Type D, 9 to 16 stations
SY3000-43-2A- SY3000-43-3A- +COM Type U, 2 to 8 stations
7 Connecter assembly
Type D, 2 to 8 stations
SY3000-43-1NA- SY3000-43-2NA- –COM Type U, 9 to 16 stations
Type D, 9 to 16 stations
SY3000-43-2NA- SY3000-43-3NA- –COM Type U, 2 to 8 stations
8 Dust cap VZ3000-63-2
Round head M3 x 26,
9 SY3000-23-4
Matt nickel plated
combination screw
10 Gasket SX3000-57-4 SX5000-57-6
11 DIN rail VZ1000-11-1- Refer to page 118.

133
SY3000/5000 Base Mounted Type 45-ANA

How to Increase Manifold Bases Station expansion is possible at any position.

1 Loosen DIN rail holding screw a fixing the manifold base until it
begins to turn idly. (While pressing DIN rail releasing buttons c ,
at two locations, separate the manifold base from the DIN rail.)

2 Press manifold block assembly dividing button b , that are at the Fig. (1) Block mounting procedure
location where manifold bases are to be added, until button b
locks, and then separate the block assemblies.
3 Mount additional manifold block assembly on the DIN rail as
shown in the figure 1.

4 Press the block assemblies until a click sound is produced, and


tighten the DIN rail holding screw a to fix them to the DIN rail.
Caution (Tightening torque: 1.4 N·m)
(While lightly holding the blocks after fixing an end block on one
side, tighten the other end block for for better sealing.) Hook the DIN rail here
and press down in the
direction of the arrow
5 Untighten the rail stopper bolt d to demount the connector box
until a click sound is
from the DIN rail, and when remounting it, tighten the bolt while heard.
pressing it against the rail.

Caution
Note 1) When there are 10 or fewer manifold block assemblies, and more are
added to make a total of 11 or more, a supply/exhaust block assembly
must also be added.
Note 2) When disassembly and assembly are performed, air leakage may
result if connections between blocks and tightening of the end block’s
holding screw, is inadequate. Before supplying air, confirm that there
are no gaps, etc. between blocks, and that manifold blocks are
securely fastened to the DIN rail. Then supply air and confirm that
there is no air leakage before operating.
Note 3) One connector assembly is necessary for one solenoid.
When a number is necessary for the connector assembly mark tube,
suffix the number to the part no. (0 to 15 are provided as mark tube
numbers.)
Ex) +COM spec.: D type for 2 to 8 stations: No. 10
SY3000-43-1A-10

How to Change Fitting Assembly

Type 45 manifold permits change in the A and B port sizes by


changing the manifold block fitting assembly.
After removing the valve, remove the clip with a screwdriver, etc. For
mounting a new fitting assembly, insert it and then insert a clip until it
will not come out of the manifold block. Clip

Fitting Assembly Part No.


Metric size
One-touch fitting for ø4 VVQ1000-50A-C4
SY3000
One-touch fitting for ø6 VVQ1000-50A-C6
One-touch fitting for ø4 VVQ1000-51A-C4
SY5000 One-touch fitting for ø6 VVQ1000-51A-C6
One-touch fitting for ø8 VVQ1000-51A-C8
Inch size
One-touch fitting for ø5 32" VVQ1000-50A-N3 Fitting assembly
SY3000
One-touch fitting for ø 1 4" VVQ1000-50A-N7
One-touch fitting for ø5 32" VVQ1000-51A-N3
SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust. O ring
Otherwise, air leakage may result.

134
5 Port Solenoid Valve
Series SY3000/5000
Base Mounted
Stacking Type/DIN Rail Mounted
Type 45 Plug-in
How to Order Manifold How to Order Valve Manifold Assembly (Example)

Type 45F (D-sub connector, 25 pins)


Example (Type 45F/D-sub connector (25 pin))
SS5Y 3 45 F D 05 U C4 -Q Single solenoid (24 VDC)
Double solenoid (24 VDC)
Series SY3140-5FU-Q (2 sets)
SY3245-5FU-Q (1 set)
3 SY3000 Blanking plate assembly
5 SY5000 SX3000-75-2A-Q (1 set)

Common specifications
- Positive common
N Negative common

Us Sta
Connector mounting position ide tion
s ..
Symbol Mounting position ....
....
U U side ....
2
1
D D side
Ds Manifold base (5 stations)
ide
Valve stations SS5Y3-45FD-05D-C6-Q
Symbol Stations Note
02 2 stations Single wining spec.
(Applicable up to 20 SS5Y3-45FD-05U-C6-Q 1 set (Type 45F, D-sub connector 5 port manifold base part no.)
...

...

20 20 stations solenoid valves.) ∗ SX3000-75-2A-Q 1 set (Blanking plate assembly part no)
∗ SY3140-5FU-Q 2 sets (Single solenoid part no.)
∗ This also includes the number of blanking ∗ SY3245-5FU-Q 1 set (Double solenoid part no.)
plate assemblies.
∗ Two stations are necessary for the double and
3 position solenoid valves (Dual body type). The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
SUP/EXH block assembly mounting position • The valve arrangement is numbered as the 1st. station from D side
Symbol Mounting position Stations regardless of the mounting position of connector box.
U U side 2 to 10 stations • When ordering double solenoid valves/3 position (Dual body type), please
D D side 2 to 10 stations keep in mind that they require two manifold stations.
B (Both sides) 2 to 20 stations
M Special specifications How to Order Valve (Type 45F, 45P, 45T, 45T1)
∗ For special specifications, indicate
separately by the manifold specification

A, B port size 2 position single SY 3 1 4 0 5 FU -Q


One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Port size
C4 One-touch fitting for ø4
Applicable series Symbol Port size
N3 One-touch fitting for ø 5 32"
Applicable series Double and 3 position SY 3 2 4 5 5 FU -Q
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000 Series
M Mixed M Mixed
3 SY3000
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
5 SY5000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16" Type of actuation
M Mixed M Mixed 2 2 position double
∗ In the case of mixed specifications (M), indicate separately on the 3 3 position closed center
manifold specification sheet. 4 3 position exhaust center
Voltage 5 3 position pressure center
- 24 VDC
12V 12 VDC Dual body type (Double, 3 position)
Rated voltage
Option 5 24 VDC
When a longer DIN rail is desired than the specified 6 12 VDC
stations, specify the station number to be required.
(20 stations at maximum) Manual override
- Non-locking push type
For external pilot specifications and built-in silencer, D Push-turn locking slotted type
refer to page 208. E Push-turn locking lever type

135
SY3000/5000 Base Mounted Type 45
How to Order Manifold
Type 45P (Flat ribbon cable)
SS5Y 3 45 P D 05 U C4 -Q Option
When a longer DIN rail is desired than the
specified stations, specify the station number to
Series be required. (20 stations at maximum)
3 SY3000 Voltage
5 SY5000 - 24 VDC
12V 12 VDC
Common specifications A, B port size
- Positive common One-touch fitting (Metric size) One-touch fitting (Inch size)
N Negative common Symbol Port size Applicable series Symbol Port size Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
Connector poles C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
Symbol Poles Stations M Mixed M Mixed
- 26 2 to 20 stations C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
G 20 2 to 16 stations C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
H 10 2 to 8 stations C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
M Mixed M Mixed
∗ In the case of mixed specifications, indicate separately on the manifold
Connector mounting position specification sheet.
Symbol Mounting position SUP/EXH block assembly mounting position
U U side
Symbol Mounting position Stations
D D side
U U side 2 to 10 stations
D D side 2 to 10 stations
B Both sides 2 to 20 stations
M Special specifications
∗ For special specifications, indicate separately
by the manifold specification sheet.
Valve stations (Blanking plate assemblies are included.)
26 pins (P) connector 20 pins (PG) connector 10 pins (PH) connector
Symbol Stations Note Symbol Stations Note Symbol Stations Note
02 2 stations Single wiring spec. 02 2 stations Single wiring spec. 02 2 stations Single wiring spec.
(Applicable up to 20 (Applicable up to 16 (Applicable up to 8
...

...

...

...

...

...

20 20 stations solenoid valves.) 16 16 stations solenoid valves.) 08 8 stations solenoid valves)


• Two stations are necessary for the double, 3 position (Dual body type).

Type 45T (9 pins terminal block) Type 45T1 (18 pins terminal block)

SS5Y 3 45T D 05 U C4 -Q SS5Y 3 45T1 D 15 B C4 -Q


Series Series
Option Option
3 SY3000 3 SY3000
When a longer DIN rail is desired When a longer DIN rail is desired
5 SY5000 than the specified stations, specify
5 SY5000 than the specified stations, specify
the station number to be required. Terminal block mounting position the station number to be required.
Terminal block mounting position
Symbol Mounting position A, B port size Symbol Mounting position A, B port size
U U side One-touch fitting (Metric size) U U side One-touch fitting (Metric size)
D D side Symbol Port size Applicable series D D side Symbol Port size Applicable series
C4 One-touch fitting for ø4 C4 One-touch fitting for ø4
Valve stations C6 One-touch fitting for ø6 SY3000
Valve stations C6 One-touch fitting for ø6 SY3000
Symbol Stations Note M Mixed Symbol Stations Note M Mixed
02 2 stations C4 One-touch fitting for ø4 02 2 stations C4 One-touch fitting for ø4
Single wiring spec. Single wining spec.
...

...

C6 One-touch fitting for ø6 C6 One-touch fitting for ø6


...

...

(Applicable up to 8 solenoid valves) SY5000 (Applicable up to 17 solenoid valves.) SY5000


08 8 stations C8 One-touch fitting for ø8 17 17 stations C8 One-touch fitting for ø8
∗ This also includes the number of M Mixed ∗ This also includes the number of M Mixed
blanking plate assemblies. blanking plate assemblies.
One-touch fitting (Inch size) One-touch fitting (Inch size)
∗ Two stations are necessary for the ∗ Two stations are necessary for the
Symbol Port size Applicable series double, 3 position (Dual body type). Symbol Port size Applicable series
double, 3 position (Dual body type).
N3 One-touch fitting for ø 5 32" N3 One-touch fitting for ø 5 32"
SUP/EXH block assembly mounting position N7 One-touch fitting for ø 1 4" SY3000 SUP/EXH block assembly mounting position N7 One-touch fitting for ø 1 4" SY3000
Symbol Mounting position Stations M Mixed Symbol Mounting position Stations M Mixed
U U side 2 to 8 stations N3 One-touch fitting for ø 5 32" U U side 2 to 10 stations N3 One-touch fitting for ø 5 32"
D D side 2 to 8 stations N7 One-touch fitting for ø1 4" D D side 2 to 10 stations N7 One-touch fitting for ø 1 4"
SY5000 SY5000
B Both sides 2 to 8 stations N9 One-touch fitting for ø 5 16" B Both sides 2 to 17 stations N9 One-touch fitting for ø 5 16"
M Special specifications M Mixed M Special specifications M Mixed
∗ For special specifications, indicate separately ∗ In the case of mixed specifications (M), ∗ For special specifications, indicate separately ∗ In the case of mixed specifications (M),
by the manifold specification sheet. indicate separately on the manifold by the manifold specification sheet. indicate separately on the manifold
Note) The terminal block (45T) manifold has no common polarity. It can be used for both positive and negative common.
136
Type 45 Base Mounted
How to Order Manifold

Type 45G (Flat cable, PC Wiring System compatible)

SS5Y 3 45G D 05 U C4 -Q
Series Option
3 SY3000 When a longer DIN rail is desired than the specified stations,
5 SY5000 specify the station number to be required. (20 stations at
maximum)
A, B port size
Connector mounting position One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Mounting position Symbol Port size Applicable series Symbol Port size Applicable series
U U side C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
D D side C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
M Mixed M Mixed
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
Valve stations C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
Symbol Stations Note SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
02 2 stations M Mixed M Mixed
Single wining spec.
...

...

(Applicable up to 16 solenoid valves.) ∗ In the case of mixed specifications, indicate separately on the
16 16 stations manifold specification sheet.
∗ Two stations are necessary for the double, 3 position
(Dual body type). SUP/EXH block assembly specifications
∗ This also includes the number of blanking plate
Symbol Specifications
assemblies. SUP/EXH block assembly - Internal pilot specifications
mounting position R External pilot specifications
Symbol Mounting position Stations S Internal pilot / Built-in silencer
U U side 2 to 10 stations RS External pilot / Built-in silencer
D D side 2 to 10 stations
B Both sides 2 to 16 stations
M Special specifications
∗ For special specifications, indicate
separately by the manifold
specification sheet.

How to Order Valve Manifold Option


Individual EXP spacer assembly Individual SUP spacer assembly
2 position
single SY 3 1 4 0 5 FU -Q
Double,
3 position SY 3 2 4 5 5 FU -Q
Series
3 SY3000
5 SY5000 t t
Type of actuation
2 2 position double
3 3 position closed center
4 3 position exhaust center
5 3 position pressure center EXH port SUP port

Dual body type


(Double, 3 position)
Pilot type Series Assembly part no. Port no. t Series Assembly part no. Port no. t
- Inernal pilot
SY3000 SY3000-39-3A M5 11 SY3000 SY3000-38-3A M5 11
R External pilot
SY5000 SY5000-39-17*A-Q 18 15 SY5000 SY5000-38-17*A-Q 18 15
Note) Please be careful becau- Note) Please be careful because the
se the dual body type dual body type (double sole-
Rated voltage (double solenoid, 3-posi- noid, 3-position) requires two
5 24 VDC tion) requires two pie- pieces. In this case, both
ces. In this case, the ex- supply ports require the piping.
Manual override haust is performed in the ∗ Thread type
direction of the arrow
- Non-locking push type - Rc
mark indicated on the
D Push-turn locking slotted type valve surface. F G
E Push-turn locking lever type N NPT
T
137 NPTF
SY3000/5000 Base Mounted Type 45
Manifold Specifications
D-sub connector Flat ribbon cable Type 45P Terminal block PCFlat ribbon cable
wiring system compatible
Model
Type 45P Type 45PG Type 45PH Type 45T Type 45T1
Type 45F Type 45G
Manifold Plug-in
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations Note 1, 2) 2 to 20 stations 2 to 16 stations 2 to 8 stations 2 to 17 stations 2 to 16 stations
A, B port Location Base
Porting specifications Direction Side
D-sub connector
SY3000 C8 (One-touch fitting for ø8)
P, R port
Port size
SY5000 C10 (One-touch fitting for ø10)
A, B port
SY3000 C4 (One-touch fitting for ø4)/C6 (One-touch fitting for ø6)
SY5000 C4 (One-touch fitting for ø4)/C6 (One-touch fitting for ø6)/C8 (One-touch fitting for ø8)
D-sub connector Flat ribbon cable connector Flat ribbon cable connector Flat ribbon cable connector Flat ribbon cable connector
Complies with Socket: 26 pins MIL type Socket: 20 pins MIL type Socket: 10 pins MIL type Terminal block Terminal block Socket: 20 pins MIL type
Applicable connector MIL-C-24308 with strain relief with strain relief with strain relief (M3) (M3) with strain relief
Flat ribbon cable JIS-X-5101 Conforming to MIL-C-83503 Conforming to MIL-C-83503 Conforming to MIL-C-83503 9 pins 18 pins Conforming to MIL-C-83503
Internal wiring +COM (Type 45), –COM (Type 45N) In common between +COM and –COM. + COM
Manifold base 2 to 10 stations: W = 26n + 172
SY3000 11 to 20 stations: W = 26n + 199
weight w (g)
n: Stations 2 to 10 stations: W = 54n + 227
(D-sub connector) SY5000 11 to 20 stations: W = 52n + 264
Note 1)For more than 11 stations, supply pressure to P port on both sides and exhaust from R port on both sides.
Terminal block Note 2)There is a limit depending on the number of solenoids. Refer to “How to Order”.

Flow Characteristics
Port size Flow characteristics
Model 1 ,5 ,3 4 ,2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P ,EA ,EB) (A ,B) C (dm3/(s·bar)) b Cv Q[l/min(ANR)]* C (dm3/(s·bar)) b Cv Q[l/min(ANR)]*
SS5Y3-45 C8 C6 0.88 0.21 0.22 212 0.95 0.18 0.22 225
SS5Y5-45 C10 C8 2.2 0.24 0.53 539 2.5 0.18 0.58 592
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
* These values have been calculated according to ISO6358 and represent the flow rate measured in standard conditions at an
Manifold Option upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.

 Blanking plate assembly  SUP blocking disk  Label for block disk
By installing a SUP blocking disk in The labels shown below are used on manifold stations containing
the pressure supply passage of a SUP/EXH block disk(s) to show their location. (3 pcs. each)
manifold valve, it is possible to VZ3000-123-1A (In common with SY3000, 5000)
supply two or more different high and Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
Note)
Short cap low pressures to one manifold.

Note) When a block disk is concurrently ordered by specifying on the manifold specification
sheet, etc., a label will be stuck on the position where block disk is mounted.
Series No.
Silencer with One-touch fitting C
SY3000 SX3000-77-1A 

SY5000 SX5000-77-1A The silencer plugs directly into the One- B


touch fittings of the manifold.
 EXH blocking disk
By installing an EXH blocking disk in
A

the exhaust passage of a manifold


Series Assembly part no. valve, it is possible to divide the valve’s
exhaust so that it does not affect Series Model Effective area A B C
SY3000 SX3000-75-2A-Q
another valve. (Two blocking disks are For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
SY5000 SX5000-76-2A-Q
needed to divide both exhausts.) AN200-KM10 26 mm2 ø22 53.8 80.8
Note)• When mounting For SY5000 (ø10)
AN300-KM10 30 mm2 ø25 70 97
blanking plate, be sure
ød

to mount a short cap.  Plug (white)


• Two stations are
øD

These are inserted in unused cylinder ports and


necessary for the
SUP, EXH ports. Purchasing order is available A
double, 3 position (Dual Series No.
body type).
in units of 10 pieces. L
SY3000 SX3000-77-1A
SY5000 SX5000-77-1A Dimensions
Applicable fittings size ød Model A L D
4 KQ2P-04 16 32 6
Caution 6 KQ2P-06 18 35 8
8 KQ2P-08 20.5 39 10
Mounting screw tightening torques 10 KQ2P-10 22 43 12
M2: 0.17 N·m 1 8" KQ2P-01 16 31.5 5
M3: 0.8 N·m 5 32" KQ2P-03 16 32 6
M4: 1.4 N·m 1 4" KQ2P-07 18 35 8.5
5 16" KQ2P-09 20.5 39 10
138
Type 45 Base Mounted
Manifold Option

 D-sub connector
1
(25 pins)/Cable assembly
2
GVVZS3000-21A- 3 -60
S
4
5

( The D-sub connector cable ass'y can be ordered individually or included


in a specific manifold model no. Refer to “How to Order Manifold”. ) Wire color table by terminal
number of D-sub connector
Type 60O cable assembly
Type Standard
Terminal No. Lead wire colour Dot marking
14 - - - - - -25 1 White –
2 Brown –
20
L

3 Green –
1- - - - - - - -13 4 Yellow –
2- M2.6x0.45

5 Grey –
6
53.5

Pink –
7 Blue –
8 Red –
9 Black –
10 Violet –
25 11 Grey Pink
L

41 12 Red Blue
41

13 White Green
14 Brown Green
15.2

15 White Yelow
53 16 Yelow Brown
D-sub connector cable ass'y
17 White Grey
Cable Electric characteristics 18 Grey Brown
Ass'y No.
length (L) 19 White Pink
Item Characteristics
1m* GVVZS3000-21A-1 20 Pink Brown
Conductor
3m GVVZS3000-21A-2 resistance 57 or less 21 White Blue
Ω/km, 20˚C 22 Brown Blue
5m GVVZS3000-21A-3
Voltage limit 23 White Red
8m GVVZS3000-21A-4 1500 24 Brown Red
V, 5min, AC
20m GVVZS3000-21A-5S Insulation 25 White Black
* Standard type is not Model resistance 20 ∗ Connector made in conformity
available for the cable Shielded cable S MΩ/km with DIN47100.
length of 1m.
60° connector 60
Standard -
 Flat Ribbon Cable Connector/Cable assembly  Dimensions/DIN rail
1
AXT100-FC - to VZ1000 11 1
3
Refer to L dimensions
Triangle mark position ∗ Fill in  with an appropriate no. listed on the table of
Red DIN rail dimensions shown below.
W

Terminal
number L

Flat Ribbon Cable Assembly


Cable length (L) 10 pins 20 pins 26 pins No. 0 1 2 3 4 5 6 7 8 9 10
1.5 m AXT100-FC10-1 AXT100-FC20-1 AXT100-FC26-1 L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223
3m AXT100-FC10-2 AXT100-FC20-2 AXT100-FC26-2 No. 11 12 13 14 15 16 17 18 19 20 21
5m AXT100-FC10-3 AXT100-FC20-3 AXT100-FC26-3 L Dimension 235.5 248 260.5 273 285.5 298 310.5 323 335.5 348 360.5
Connector width (W) 17.2 30 37.5
No. 22 23 24 25 26 27 28 29 30 31 32
∗ For other commercial connectors, use a type with strain relief
L Dimension 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498
that conform to MIL-C-83503.
No. 33 34 35 36 37 38 39 40 41 42 43
Connector manufacturers’ example L Dimension 510.5 523 535.5 548 560.5 573 585.5 598 610.5 623 635.5
• Hirose Electric Co., Ltd. No. 44 45 46 47 48 49 50 51 52 53 54
• Sumitomo 3M Limited L Dimension 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773
• Fujitsu Limited
No. 55 56 57 58 59 60 61 62 63 64 65
• Japan Aviation Electronics Industry, Ltd.
• J.S.T. Mfg. Co., Ltd.
L Dimension 785.5 798 810.5 823 835.5 848 860.5 873 885.5 898 910.5
No. 66 67 68 69 70 71
L Dimension 923 935.5 948 960.5 973 985.5
∗ Refer to L1 dimension on pages starting with page 145 for lengths that
correspond to the number of manifold stations.

139
SY3000/5000 Base Mounted Type 45
Manifold Internal Wiring

45(N)F/D-sub Connector <For positive common (45F)> <For negative common (45NF)>
A D-sub connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.
Positive pole (common) Positive pole

Negative Pole Negative Pole (common)

Not use Not use

Light/surge
Station 20 Station 20
Light/surge
voltage voltage
suppressor suppressor
Station 5 SOL. B (Double solenoid Station 5 SOL. B (Double solenoid
St
ati
}
Station 4 SOL. A Dual body type)
}
Station 4 SOL. A Dual body type)
U on Light/surge Light/surge
sid s. voltage voltage
e .... suppressor suppressor
.2
1 Station 3 (Single solenoid) Station 3 (Single solenoid)
Light/surge Light/surge
voltage voltage
suppressor Station 2 (Single solenoid) suppressor Station 2 (Single solenoid)

D Station 1 (Single solenoid) Station 1 (Single solenoid)


sid Light/surge Light/surge
e voltage
suppressor
voltage
suppressor

Power supply terminal Power supply terminal

• The power source terminal is used for connecting to an external power source.
• The maximum number of stations that can be accommodated is 20 manifold stations, with up to 20
solenoids.(For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.

Type 45(N)P/Flat Ribbon Cable (26 pins) <For positive common (45P)> <For negative common (45NP)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.
Positive pole (common) Positive pole
Negative pole Negative pole (common)

Not use Not use


Station 20 Station 20

Light/surge Light/surge
voltage voltage
suppressor

} }
suppressor
Station 5 SOL. B (Double solenoid Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type) Station 4 SOL. A Dual body type)
St
U ati Light/surge Station 3 (Single solenoid) Station 3 (Single solenoid)
sid on voltage
Light/surge
e s. suppressor
voltage
suppressor
....
.. 2 Light/surge Light/surge
1 voltage
suppressor Station 2 (Single solenoid) voltage
suppressor Station 2 (Single solenoid)
Station 1 (Single solenoid) Station 1 (Single solenoid)
Triangle mark Triangle mark
D Light/surge Light/surge
sid voltage voltage
e suppressor suppressor

Power supply terminal Power supply terminal

Note)
Terminal numbers are not
Triangle mark indicated on the connectors.
The terminal numbers • The power source terminal is used for connecting to an external power source.
indicated in the connector • The maximum number of stations that can be accommodated is 20 manifold stations, with up to 20
schematic shown on the right solenoids. (For more stations, please contact SMC.)
show the correlation if the
inserted connector's flat ribbon
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
cable were numbered 1 to 26
from the triangle mark side, as
Reference figure shown in the figure to the left.

140
Type 45 Base Mounted
Manifold Internal Wiring

Type 45(N)PG/Flat Ribbon Cable (20 pins) <For positive common (45PG)> <For negative common (45NPG)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.

Positive pole (common) Positive pole

Negative pole Negative pole (common)


Station 16 Station 16

Light/surge Light/surge
voltage voltage
Station 5 SOL. B (Double solenoid
}
suppressor suppressor
Station 5 SOL. B (Double solenoid
St
ati
Station 4 SOL. A Dual body type) }
Station 4 SOL. A Dual body type)
on Light/surge
Station 3 (Single solenoid) Light/surge Station 3 (Single solenoid)
U s. voltage voltage
sid .... suppressor suppressor
....
e 2 Light/surge Light/surge
1 voltage
suppressor Station 2 (Single solenoid)
voltage
suppressor Station 2 (Single solenoid)
Station 1 (Single solenoid) Station 1 (Single solenoid)
Light/surge
Triangle mark Triangle mark
Light/surge
voltage voltage
D suppressor suppressor
sid
e

Power supply terminal Power supply terminal

Note)
Terminal numbers are not
Triangle mark indicated on the connectors.
The terminal numbers
indicated in the connector
schematic shown on the right
show the correlation if the
• The power source terminal is used for connecting to an external power source.
inserted connector's flat ribbon • The maximum number of stations that can be accommodated is 16 manifold stations, with up to 16
cable were numbered 1 to 26 solenoids. (For more stations, please contact SMC.)
from the triangle mark side, as • Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
Reference figure shown in the figure to the left.

Type 45(N)PH/Flat Ribbon Cable (10 pins) <For positive common (45PH)> <For negative common (45NPH)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.

Positive pole (common) Positive pole


Negative pole Negative pole (common)
Station 8 Station 8

Light/surge Light/surge
voltage voltage

} }
suppressor suppressor
Station 5 SOL. B (Double solenoid Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type) Station 4 SOL. A Dual body type)
Light/surge
voltage
Station 3 (Single solenoid) Light/surge
voltage
Station 3 (Single solenoid)
St suppressor suppressor
ati
U on Light/surge Light/surge
sid s. voltage
Station 2 (Single solenoid) voltage Station 2 (Single solenoid)
e .... suppressor suppressor
.. 2
1 Station 1 (Single solenoid) Station 1 (Single solenoid)
Triangle mark Triangle mark
Light/surge Light/surge
voltage voltage
suppressor suppressor

D
sid
e

Note)
Terminal numbers are not Power supply terminal Power supply terminal
Triangle mark indicated on the connectors.
The terminal numbers indicated
in the connector schematic
shown on the right show the
correlation if the inserted • The power source terminal is used for connecting to an external power source.
connector's flat ribbon cable • The maximum number of stations that can be accommodated is 8 manifold stations, with up to 8 solenoids.
were numbered 1 to 26 from the (For more stations, please contact SMC.)
triangle mark side, as shown in
the figure to the left. • Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
Reference figure

141
SY3000/5000 Base Mounted Type 45
Manifold Internal Wiring

Type 45T/Terminal Block (45T)


A terminal block style permits direct cable
connection without treatment of lead wires.

Station 8
Light/surge
voltage
suppressor

}
Light/surge
voltage Station 5 SOL. B
suppressor
(Double solenoid
Dual body type)
Light/surge
voltage
suppressor Station 4 SOL. A

St
ati
on Light/surge
U s. voltage Station 3 (Single solenoid)
sid .... suppressor
e ....
2
1 Light/surge
voltage
suppressor Station 2 (Single solenoid)

D
sid Light/surge
Station 1 (Single solenoid)
e voltage
suppressor

Common (+, –)

• The maximum number of stations that can be accommodated is 8 manifold stations, with up to 8 solenoids.
(For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
• There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for
–COM spec.

Type 45T1/Terminal Block (45T1)

Station 17

Station 8
Light/surge
voltage
suppressor

}
St
ati Light/surge Station 5 SOL. B
on voltage
U s. suppressor
(Double solenoid
sid ....
e .... Dual body type)
2 Light/surge
1 voltage
suppressor Station 4 SOL. A

D Light/surge
voltage Station 3 (Single solenoid)
sid suppressor
e
Light/surge
voltage
suppressor Station 2 (Single solenoid)

Light/surge
voltage Station 1 (Single solenoid)
suppressor

Station 9
Common (+, –)

• The maximum number of stations that can be accommodated is 17 manifold stations, with up to 17 solenoids.
(For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
• There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for –COM
spec.

142
Type 45 Base Mounted
Manifold Internal Wiring

Type 45G Flat Ribbon Cable


(PC Wiring System compatible) Electric circuit diagram
(Below wiring is the case of all double solenoid connections.)
It’s the manifold for 20 pins flat ribbon cable
connector which is compliant for PC wiring
system. Cable connector for flat ribbon cable Terminal no.
SOL.A 20
1 station { SOL.B 18
SOL.A 16
2 stations { SOL.B 14
SOL.A 12
3 stations { SOL.B 10
SOL.A 8
4 stations { SOL.B 6
SOL.A 19
5 stations { SOL.B 17
SOL.A 15
Us
2
+C 4VD
OM C 6 stations { SOL.B 13
e
ide typ
Sta W
Connector terminal number SOL.A 11
PC
tion 7 stations {
C
SM

s SOL.B 9
SOL.A 7
3 8 stations { SOL.B 5
2
1
Triangle mark position
3.4
D
sid
e 24 VDC –+
1.2

• The maximum number of stations that can be accommodated is 16 manifold stations, with
up to 16 solenoids. (For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as
the 1st one.
For details about the PC wiring system, refer to
catalogue CAT.ES02-20 separately.

143
SY3000/5000 Base Mounted Type 45
How to Connect SS5Y-45 (Plug-in)

Power terminal is equipped with plug-in manifold of Series SY as standard.


Power terminal enables the power supply to valve from either of manifold or controller side.

1. Wiring example when using manifold power supply terminals

SY manifold internal wiring


(Flat ribbon cable, plus common specification)
Controller side (PLC, etc.)
(NPN open collector output)
PLC

Negative pole

Manifold valve
(SS5Y3-45PGD-05U--Q)

DC power supply

Solenoid valve
Power Triangle Cable assembly
supply mark AXT100-FC20-, etc.
terminal

Power supply

2. Wiring example when not using manifold power supply terminals


(Power is supplied to the controller side or along the wiring, etc.)

Power supply
SY manifold internal wiring
(Flat ribbon cable, plus common specification)
Controller side (PLC, etc.)
PLC Positive pole (NPN open collector output)

Manifold valve
(SS5Y3-45PGD-05U--Q)

DC power supply

Solenoid valve
Power Triangle Cable assembly
supply mark AXT100-FC20-, etc.
terminal

Caution
• Single wire, COM position, etc. of PLC are different from each manufacturer. When
connecting with PLC, read the specifications carefully and understand the electrical
circuit. Poor wiring could cause damage to PLC, power source, etc. as well as manifold
and valve.

144
Type 45 Base Mounted
SY3000: D-sub Connector/Plug-in
(Station n) (Station 1)
(Light/surge voltage suppressor)
SS5Y3-45FU- Stations D-C4, N3
C6, N7 -Q
M3 7
Terminal screw

63.3
39.5

7.5

34.5
Block separation button
(Push type)
U side D side
Equivalent to the applicable (L4)
D-sub connector {JIS-X-5101, MIL-C-24308} L3

(C6: 3.2)
DIN rail holding screw

(N7: 7)
26.5
M2.6

(3)
DIN rail
8

34
PORT

PORT
B B B

SOL.a

SOL.a
SOL.b

SOL.b
5.5
35

87.7
A A A
92

3.9

15.7
Note) The L1 to L4 dimensions of SS5Y3-45FU-
24VDC

Stations U-C4, N3
C6, N7 -Q are identical to those
+COM
- +

of SS5Y3-45FU- Stations D- C4, N3


C6, N7 -Q.
Terminal no. 1 Power supply terminals (
Press and turn to operate
Manual override and lock override. )
(The voltage indication
marking is for 24 VDC. ) A side: Blue
Stations n 2 stations 3 4 5 6 7 8 9 10 stations L2 5 B side: Yellow
L1 123 135.5 148 148 160.5 173 185.5 198 210.5 (Rail mounting hole pitch: 12.5)
L1
L2 112.5 125 137.5 137.5 150 162.5 175 187.5 200
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 (Pitch) Button for DIN rail release
P = 10.5 13.5 24.8
11.2

10.2
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
22.2

A A A A A R

25.2
B B B B B
P

One-touch fitting One-touch fitting


(A, B port) (P, R port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø8, ø5/16"
ø6, ø1/4"

SS5Y3-45FU- Stations B- C4, N3


C6, N7 -Q
U side D side
Equivalent to the applicable (L4)
D-sub connector {JIS-X-5101, MIL-C-24308} L3
(C6: 3.2)

26.5 DIN rail holding screw


(N7: 7)

M2.6
(3)

DIN rail
8
PORT

PORT

34

B B B
5.5

SOL.a

SOL.a
SOL.b

SOL.b
35

15.7
87.7
92

A A A
3.9

24VDC
+COM
- +

Terminal no. 1 Manual override

( Press and turn to operate


and lock override. )
A side: Blue
Power supply terminals B side: Yellow
Stations n 2 stations 3 4 5 6 7 8 9 10 stations ( The voltage indication
marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L2 5
L1 135.5 148 160.5 173 185.5 185.5 198 210.5 223 L1
L2 125 137.5 150 162.5 175 175 187.5 200 212.5
L3 108 118.5 129 139.5 150 160.5 171 181.5 192
(Pitch) Button for DIN rail release
45.8 P = 10.5 13.5 24.8
10.2

11.2

L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5


Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
R R
22.2
25.2

A A A A A

L1 235.5 248 248 260.5 273 285.5 298 310.5 310.5 323
L2 225 237.5
B B B B B

237.5 250 262.5 275 287.5 300 300 312.5 P P

L3 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297 One-touch fitting
L4 16.5 17.5 12 13 14 15 16 17 12 13 One-touch fitting
(P, R port)
(A, B port)
Applicable tubing O.D.: ø8, ø5/16"
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
145
SY3000/5000 Base Mounted Type 45
SY3000: D-sub Connector/Plug-in

SS5Y3-45FD- Stations U- C4, N3


C6, N7 -Q
(Station n) (Station 1)
(Light/surge voltage suppressor)

7 M3
Note) The L1 to L4 dimensions of SS5Y3-45FD- Terminal screw
Stations D- C4, N3
C6, N7 -Q are identical to those of

63.3
SS5Y3-45FD- Stations U- C4,N3
C6,N7-Q.

39.5
7.5
34.5
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 123 135.5 148 148 160.5 173 185.5 198 210.5 Block separation button
L2 112.5 125 137.5 137.5 150 162.5 175 187.5 200 (Push type)
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 U side D side
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 L3 (L4) Equivalent to the applicable
D-sub connector {JIS-X-5101, MIL-C-24308}

(C6: 3.2)
(N7: 7)
DIN rail holding screw M2.6 27.5
DIN rail

(3)
8
34

PORT

PORT
B B B

5.5
SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7

A A A
92

3.9
24VDC
+COM
- +

Manual override Terminal no. 1 Power supply terminals

( Press and turn to operate


and lock override. ) L2 5 ( The voltage indication
marking is for 24 VDC. )
A side: Blue (Rail mounting hole pitch: 12.5)
B side: Yellow L1
(Pitch) Button for DIN rail release
24.8 13.5 P = 10.5 42.8 11.2
10.2

22.2
R A A A A A
25.2

B B B B B
P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø8, ø5/16" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"

SS5Y3-45FD- Stations B-C4,N3


C6,N7
-Q

U side D side
L3 (L4)
Equivalent to the applicable
(C6: 3.2)

DIN rail holding screw M2.6 27.5 D-sub connector


(N7: 7)

DIN rail {JIS-X-5101, MIL-C-24308}


(3)

8
34

PORT

PORT

B B B
5.5
SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7

A A A
92

3.9

24VDC
+COM
- +

Power supply terminals


Manual override Terminal no. 1
( )
The voltage indication
Stations n 2 stations 3 4 5 6 7 8 9
L1 135.5 148 160.5 173 185.5 185.5 198 210.5
10 stations
223
( Press and turn to operate
and lock override. ) L2 5
marking is for 24 VDC.

A side: Blue (Rail mounting hole pitch: 12.5)


L2 125 137.5 150 162.5 175 175 187.5 200 212.5 B side: Yellow L1
L3 108 118.5 129 139.5 150 160.5 171 181.5 192 (Pitch) Button for DIN rail release
L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 24.8 P = 10.5 13.5 45.8
10.2
11.2

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations R R


22.2

25.2

A A A A A

L1 235.5 248 248 260.5 273 285.5 298 310.5 310.5 323
L2 225 237.5 237.5 250 262.5 275 287.5 300 300 312.5 B B B B B

L3 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297
P P

L4 16.5 17.5 12 13 14 15 16 17 12 13
One-touch fitting
One-touch fitting
(P, R port) (A, B port)
Applicable tubing O.D.: ø8, ø5/16" Applicable tubing O.D.: ø4, ø5/32" ø6, ø1/4"

146
Type 45 Base Mounted
SY5000: D-sub Connector/Plug-in
C4, N3
SS5Y5-45FU- Stations D- C6, N7 -Q
C8, N9 (Station n) (Station 1)
(Light/surge voltage suppressor)

M3 7
Terminal screw

71.1
47.7

42.7
7.5
Block separation button
(Push type)

U side (L4) D side


Equivalent to the applicable L3
D-sub connector {JIS-X-5101, MIL-C-24308} DIN rail holding screw

(4.9)
(3.5)
27 M2.6

Note) The L1 to L4 dimensions of SS5Y5-45FU- 8 DIN rail


41.2

C4, N3
Stations U- C6, N7 -Q are identical to those of

PORT

PORT
B B
5.5

C8, N9 C4, N3
35

SS5Y5-45FU- Stations D- C6, N7 -Q.

SOL.a

SOL.a
C8, N9

SOL.b

SOL.b
114.3

19.4
110.4

31.2
Stations n 2 stations 3 4 5 6 7 8 9 10 stations A A A

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5


L2 125 137.5 150 175 187.5 200 225 237.5 250 24VDC

L3 105 121 137 153 169 185 201 217 233 +COM
- +

L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


Terminal no. 1
Power supply terminals L2 5 Manual override

( The voltage indication


marking is for 24 VDC. )
(Rail mounting hole pitch: 12.5)
L1
(Depress and turn to operate
and lock override.
A side: Blue
)
B side: Yellow
One-touch fitting (Pitch)
(A, B port) P = 16 17 26 Button for DIN rail release
Applicable tubing O.D.: ø4, ø5/32"
15.5

ø6, ø1/4"
31.5

32
ø8, ø5/16"
14.5
A A A A A R

B B B B B P

One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
C4, N3
SS5Y5-45FU- Stations B- C6, N7 -Q
C8, N9 U side
Equivalent to the applicable L3 (L4) D side
D-sub connector {JIS-X-5101, MIL-C-24308}
(4.9)
(3.5)

27 M2.6
DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

31.2

A A A

24VDC
+COM
- +

Terminal no. 1 Power supply terminals Manual override

( marking is for 24 VDC. ) ( and lock override. )


The voltage indication Press and turn to operate
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
A side: Blue
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5 B side: Yellow
L2 137.5 162.5 175 187.5 200 225 237.5 250 275 L2 5
L3 123 139 155 171 187 203 219 235 251 (Rail mounting hole pitch: 12.5)
L1
L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
(Pitch) Button for DIN rail release
47 P = 16 17 26
L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
15.5
14.5

31.5

L3 267 283 299 315 331 347 363 379 395 411
32

R A A A A A R

L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12


P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
147 ø8, ø5/16"
SY3000/5000 Base Mounted Type 45
SY5000: D-sub Connector/Plug-in
C4, N3
SS5Y5-45FD- Stations U- C6, N7 -Q
C8, N9
(Station n) (Station 1)
(Light/surge voltage suppressor)

7 M3
Note) The L1 to L4 dimensions of SS5Y5-45FD- Terminal screw
C4, N3
Stations D- C6, N7 -Q are identical to those of

71.1
C8, N9 C4, N3
SS5Y5-45FD- Stations U- C6, N7 -Q.

47.6
42.7
C8, N9

7.5
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 135.5 1 48 160.5 185.5 198 210.5 235.5 248 260.5
L2 125 137.5 150 175 187.5 200 225 237.5 250 Block separation button
(Push type)
L3 105 121 137 153 169 185 201 217 233 U side D side
L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5 L3 (L4) Equivalent to the applicable
D-sub connector {JIS-X-5101, MIL-C-24308}

(4.9)
DIN rail holding screw

(3.5)
28

DIN rail
8

41.2
PORT

PORT
B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4
31.2

A A A

24VDC
+COM
- +

Manual override Power supply terminals


Terminal no. 1 M2.6
( Press and turn to operate
and lock override. ) L2
(Rail mounting hole pitch: 12.5)
5 ( The voltage indication
marking is for 24 VDC. )
A side: Blue L1
B side: Yellow
26 17 (Pitch) 46 Button for DIN rail release
P = 16
14.5

31.5
32

15.5

R A A A A A

P B B B B B

One-touch fitting One-touch fitting


(P, R port) (A, B port)Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8" ø6, ø1/4"
ø8, ø5/16"
C4, N3
SS5Y5-45FD- Stations B-C6, N7 -Q
C8, N9

DIN rail holding screw U side L3 (L4) D side


Equivalent to
DIN rail the applicable
(4.9)
(3.5)

Stations n 2 stations 3 4 5 6 7 8 9 10 stations 28 D-sub connector


L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5 {JIS-X-5101, MIL-C-24308}
L2 137.5 162.5 175 187.5 200 225 237.5 250 275 8
L3 123
19.4 41.2

139 155 171 187 203 219 235 251


PORT

PORT

B B

L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17


5.5
35
SOL.a

SOL.a
SOL.b

SOL.b

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations


114.3

110.4
31.2

L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5 A A A

L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
L3 267 283 299 315 331 347 363 379 395 411
L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 24VDC
+COM
- +

Manual override Terminal no. 1 M2.6 Power supply terminals


( Press and turn to operate
and lock override. ) L2
(Rail mounting hole pitch: 12.5)
5
( The voltage indication
marking is for 24 VDC.)
A side: Blue L1
B side: Yellow
26 (Pitch) 17 47 Button for DIN rail release
P = 16
15.5
31.5

32
14.5

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
148
Type 45 Base Mounted
SY3000: Flat Ribbon Cable/Plug-in
SS5Y3-45PU- Stations D- C4, N3
C6, N7 -Q (26 pins) (Station n) (Station 1)
(Light/surge voltage suppressor)

M3
Terminal screw

63.3
Note) The L1 to L4 dimensions of SS5Y3-45PU-
7

39.5

7.5
34.5
Stations U- C4, N3
C6, N7 -Q are identical to those of

SS5Y3-45PlU- Stations D-C4, N3


C6, N7 -Q.

Block separation button


Applicable connector: Applicable connector: (Push type)
20 pins MIL type 10 pins MIL type
U side L3 (L4) D side
(Conforming to (Conforming to Applicable connector: 26 pins MIL type
MIL-C-83503) MIL-C-83503)

(C6: 3.2)
(N7: 7)
With strain releaf 28.4 DIN rail holding screw
(Conforming to MIL-C-83503)

(3)
DIN rail
Triangle mark 8
Triangle mark position

34
PORT

PORT
B B B

5.5
position

SOL.a

SOL.b
SOL.b

SOL.a
35

87.7
A A A
92

3.9
24VDC 24VDC

15.7
+COM +COM
– + – +

24VDC
+COM
– +

Type 45PG (20 pins) Type 45PH (10 pins)

Power supply terminals


Stations n 2 stations
L1 123
3
135.5
4
148
5
148
6
160.5
7
173
8
185.5
9 10 stations
198 210.5
( marking is for 24 VDC. )
The voltage indication
Manual override

L2 112.5 125 137.5 137.5 150 162.5 175 187.5 200


Triangle mark position
L2 5
( Press and turn to operate
and lock override. )
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5
(Rail mounting hole pitch: 12.5) A side: Blue
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 L1 B side: Yellow
Button for DIN rail release
13.5 24.8
11.2

(Pitch)

10.2
P = 10.5
22.2

A A A A A R

25.2
B B B B B
P

One-touch fitting One-touch fitting


(A, B port) (P, R port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø8, ø5/16"
ø6, ø1/4"
SS5Y3-45PU- Stations B-C4, N3
C6, N7 -Q (26 pins)
U side L3 (L4) D side
Applicable connector: 26 pins MIL type
(C6: 3.2)
(N7: 7)

With strain releaf 28.4 DIN rail holding screw


(Conforming to MIL-C-83503)
(3)

DIN rail
8
34
PORT

PORT

B B B
5.5

SOL.a

SOL.a
SOL.b

SOL.b
35

15.7
87.7

A A A
92

3.9

24VDC
+COM
– +

Power supply terminals


Manual override
(
The voltage indication
marking is for 24 VDC. ) ( Press and turn to operate
and lock override. )
Triangle mark position
A side: Blue
Stations n 2 stations 3 4 5 6 7 8 9 10 stations L2 5 B side: Yellow
L1 135.5 148 160.5 173 185.5 185.5 198 210.5 223 (Rail mounting hole pitch: 12.5)
L1
L2 125 137.5 150 162.5 175 175 187.5 200 212.5
L3 108 118.5 129 139.5 150 160.5 171 181.5 192 (Pitch) Button for DIN rail release
L4 13.5 45.8 P = 10.5 13.5 24.8
10.2

11.2

14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5


Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations R R
22.2

A A A A A
25.2

L1 235.5 248 248 260.5 273 285.5 298 310.5 310.5 323
L2 225 237.5 237.5 250 262.5 275 287.5 300 300 312.5 B B B B B

One-touch fitting
P P
L3 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297
(P, R port)
L4 16.5 17.5 12 13 14 15 16 17 12 13
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
149 ø6, ø1/4"
SY3000/5000 Base Mounted Type 45
SY3000: Flat Ribbon Cable/Plug-in
SS5Y3-45PD- Stations U-C4,N3
C6,N7 -Q (26 pins)
(Station n) (Station 1)
(Light/surge voltage suppressor)
M3
Terminal screw

63.3
7

39.5
7.5
34.5
Block separation button
(Push type)

U side D side Applicable connector: 26 pins MIL type


(L4) With strain releaf
L3
(Conforming to MIL-C-83503)
DIN rail holding screw

(C6: 3.2)
(N7: 7)
25.6
DIN rail

(3)
8

34

PORT

PORT
B B B

5.5
Triangle mark position

SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7
A A A
92

3.9
24VDC
+COM
– +

Manual override Power supply terminals

( Press and turn to operate


and lock override. ) ( The voltage indication
marking is for 24 VDC. )
Note) The L1 to L4 dimensions of SS5Y3-45PD- A side: Blue
B side: Yellow L2 5
Stations D- C4, N3
C6, N7 -Q are identical to those of
(Rail mounting hole pitch: 12.5)
SS5Y3-45PD- Stations U-C4, N3
C6, N7-Q. L1
(Pitch) Button for DIN rail release
Stations n 2 stations 3 4 5 6 7 8 9 10 stations 24.8 13.5 P = 10.5 42.8

11.2
10.2

L1 123 135.5 148 148 160.5 173 185.5 198 210.5

22.2
R
L2 112.5 125 137.5 137.5 150 162.5 175 187.5
A A A A A
25.2

200
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 B B B B B
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø8, ø5/16" Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4"
SS5Y3-45PD- Stations B- C4,N3
C6,N7 -Q (26 pins) U side D side
Applicable connector:
L3 (L4) 26 pins MIL type
DIN rail holding screw With strain releaf
(C6: 3.2)
(N7: 7)

25.6
DIN rail (Conforming to MIL-C-83503)
(3)

8
34

PORT

PORT

B B B
5.5
SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7

A A A
92

3.9

24VDC
+COM
– +

Manual override Power supply terminals Triangle mark

( Press and turn to operate


and lock override. ) ( The voltage indication
marking is for 24 VDC. ) position

A side: Blue
Stations n 2 stations 3 4 5 6 7 8 9 10 stations B side: Yellow L2 5
L1 135.5 148 160.5 173 185.5 185.5 198 210.5 223 (Rail mounting hole pitch: 12.5)
L2 125 137.5 150 162.5 175 175 187.5 200 212.5
242 L1
L3 108 118.5 129 139.5 150 160.5 171 181.5 192 (Pitch) Button for DIN rail release
L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 24.8 P = 10.5 13.5 45.8
10.2
11.2

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations


L1 235.5 248 248 260.5 273 285.5 298 310.5 310.5 323
22.2

R A A A A A R
25.2

L2 225 237.5 237.5 250 262.5 275 287.5 300 300 312.5
L3 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297
B B B B B
P P

L4 16.5 17.5 12 13 14 15 16 17 12 13
One-touch fitting One-touch fitting
(A, B port) (P, R port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø8, ø5/16"
ø6, ø1/4"
150
Type 45 Base Mounted
SY5000: Flat Ribbon Cable/Plug-in
C4, N3
SS5Y5-45PU- Stations D- C6, N7 -Q (26 pins)
(Station n) (Station 1)
(Light/surge voltage suppressor)

M3
Terminal screw

71.1
Note) The L1 to L4 dimensions of SS5Y5-45PU- 7

47.7

42.7
C4, N3

7.5
Stations U- C6, N7 -Q
C8, N9
are identical to those of
C4, N3
SS5Y5-45PU- Stations D- C6, N7 -Q.
C8, N9

Block separation button


U side (Push type) D side
Applicable connector: Applicable connector: Applicable connector: 26 pins MIL type L3 (L4)
20 pins MIL type 10 pins MIL type
With strain releaf DIN rail holding screw

(4.9)
(3.5)
(Conforming to (Conforming to 28.9
MIL-C-83503) MIL-C-83503) (Conforming to MIL-C-83503)

8 DIN rail
41.2

PORT

PORT
5.5 B B
35

Triangle mark

SOL.a
SOL.b
SOL.a
SOL.b
position
114.3

19.4

Triangle mark
110.4

31.2
position A A A

24VDC 24VDC
+COM +COM 24VDC
– + – + +COM
– +

Type 45PG (20 pins) Type 45PH (10 pins) Triangle mark position Manual override
Power supply terminals

( The voltage indication


marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L2 (and lock override.
5 Depress and turn to operate )
A side: Blue
L1
B side: Yellow
C8, N9 (Pitch) 17 26 Button for DIN rail release
P = 16
15.5
31.5

32
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
14.5
A A A A A R

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5


L2 125 137.5 150 175 187.5 200 225 237.5 250
B B B B B
One-touch fitting
P

One-touch fitting
L3 105 121 137 153 169 185 201 217 233 (P, R port)
(A, B port)
Applicable tubing O.D.: ø10, ø3/8"
L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5 Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
C4, N3
SS5Y5-45PU- Stations B- C6, N7 -Q (26 pins) U side D side
C8, N9
L3 (L4)
Applicable connector: 26 pins MIL type
(4.9)

With strain releaf


(3.5)

28.9
(Conforming to MIL-C-83503) DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

31.2

A A A

Manual override

( )
Press and turn to operate
24VDC
+COM
– +
and lock override.
A side: Blue
Power supply terminals Triangle mark position B side: Yellow

( marking is for 24 VDC. )


The voltage indication
(Rail mounting hole pitch: 12.5)
L2 5

L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5 (Pitch)
47 P = 16 17 26 Button for DIN rail release
L2 137.5 162.5 175 187.5 200 225 237.5 250 275
L3 123 139 155 171 187 203 219 235 251
14.5

15.5
31.5

L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17


32

R A A A A A R

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations


L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5 P B B B B B P

L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425 One-touch fitting
L3 267 283 299 315 331 347 363 379 395 411 One-touch fitting (P, R port)
L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 Applicable tubing O.D.: ø10, ø3/8"
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
151 ø8, ø5/16"
SY3000/5000 Base Mounted Type 45
SY5000: Flat Ribbon Cable/Plug-in
C4, N3
SS5Y5-45PD- Stations U- C6, N7 -Q (26 pins) (Station n) (Station 1)
C8, N9
(Light/surge voltage suppressor)

M3
Terminal screw

71.1

47.6
42.7

7.5
Note) The L1 to L4 dimensions of SS5Y5-45PD-
C4, N3
Stations D- C6, N7 -Q are identical to those of
C8, N9 Block separation button
C4, N3
SS5Y3-45PD- Stations U- C6, N7 -Q.
C8, N9
(Push type)
U side L3 (L4) D side
DIN rail holding screw Applicable connector: 26 pins MIL type

(4.9)
(3.5)
28 With strain releaf
DIN rail
(Conforming to MIL-C-83503)
8

41.2
PORT

PORT
B B
5.5
35

SOL.a
SOL.a

SOL.b
SOL.b
Triangle mark position
114.3

19.4
110.4
31.2

A A A

24VDC
+COM
– +

Power supply terminals


Manual override

( Press and turn to operate


and lock override. )
L2
(Rail mounting hole pitch: 12.5)
5
( The voltage indication
marking is for 24 VDC. )
A side: Blue L1
B side: Yellow
26 17 (Pitch) 46 Button for DIN rail release
P = 16
Stations n 2 stations 3 4 5 6 7 8 9 10 stations

15.5
14.5

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5

31.5
32

L2 125 137.5 150 175 187.5 200 225 237.5 250 R A A A A A

L3 105 121 137 153 169 185 201 217 233 P B B B B B

L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


One-touch fitting One-touch fitting
(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
C4, N3 ø8, ø5/16"
SS5Y5-45PD- Stations B-C6, N7 -Q (26 pins)
C8, N9
U side L3 (L4) D side
DIN rail holding screw Applicable connector: 26 pins MIL type
(4.9)
(3.5)

28 With strain releaf


DIN rail
(Conforming to MIL-C-83503)
8
19.4 41.2
PORT

PORT

B B
5.5
35
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2

A A A

24VDC
+COM
– +

Manual override Triangle mark position Power supply terminals

(Press and turn to operate


and lock override. ) (Rail mounting hole pitch: 12.5)
L2 ( marking is for 24 VDC.)
5 The voltage indication
A side: Blue
B side: Yellow L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(Pitch)
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5 26 P = 16 17 47 Button for DIN rail release
L2 137.5 162.5 175 187.5 200 225 237.5 250 275
14.5
15.5

L3 123 139 155 171 187 203 219 235 251


31.5

32

L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17 R A A A A A R

Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations P B B B B B P

L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
L3 267 283 299 315 331 347 363 379 395 411 One-touch fitting One-touch fitting
L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 (P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"152
Type 45 Base Mounted
SY3000: 9 Pins Terminal Block/Plug-in
SS5Y3-45TU- Stations D-C4, N3
C6, N7 -Q (9 pins)
(Light/surge voltage suppressor) (Station n) (Station 1)

63.2

63.3
34.5
7.5
Block separation button
(Push type)
U side L3 (L4) D side

(C6: 3.2)
M3

(N7: 7)
27 DIN rail holding screw
Terminal

(3)
screw DIN rail
8

8
8

PORT

PORT

34
B B B
Note) The L1 to L4 dimensions of SS5Y3-45TU-

7
5.5

6
SOL.a

SOL.a
SOL.b

SOL.b
35

6
C4, N3
Stations U- C4,
C6, N7-Q, SS5Y3-45TD- Stations U-C6, N7-Q
N3

87.7
5
92
A A A

4
4
, SS5Y3-45TD- Stations D- C4, N3
C6, N7 -Q are identical

3
3

6
15.7
2
2
those of SS5Y3-45TU- Stations D- C4, N3
C6, N7 -Q.

1
1 COM

COM
Stations n 2 stations 3 4 5 6 7 8 stations
Manual override
L1 123 135.5 148 148 160.5 173 185.5
L2 112.5
L3 91.5
125 137.5 137.5 150 162.5 175
102 112.5 123 133.5 144 154.5
L2
(Rail mounting hole pitch: 12.5)
( and lock override.
5 Press and turn to operate
)
A side: Blue
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 L1 B side: Yellow
Button for DIN rail release
(Pitch) 13.5 24.8

10.2
11.2

P = 10.5

25.2
R
22.2

A A A A A

B B B B B
One-touch fitting
P

P, R port
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
A, B port
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45TU- Stations B- C4, N3
C6, N7 -Q (9 pins)
U side L3 (L4) D side
(C6: 3.2)

27 M3 DIN rail holding screw


(N7: 7)
(3)

Terminal screw DIN rail


8
8

34
PORT

PORT

B B B
7

SOL.a

SOL.a
SOL.b

SOL.b
6

6
35

87.7
5

5
92

A A A
15.7
5.5

4
3

3
2

2
1 COM

COM 1

Note) The L1 to L4 dimensions of SS5Y3-45TD-


Manual override
Stations B- C4, N3
C6, N7 -Q are identical to those of

SS5Y3-45TU- Stations B-C4, N3


C6, N7-Q.
( Press and turn to operate
and lock override. )
A side: Blue
B side: Yellow
Stations n 2 stations 3 4 5 6 7 8 stations L2 5
L1 135.5 148 160.5 173 185.5 185.5 198 (Rail mounting hole pitch: 12.5)
L2 125 137.5 150 162.5 175 175 187.5
L1
L3 108 118.5 129 139.5 150 160.5 171
L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 (Pitch) Button for DIN rail release
45.8 P = 10.5 13.5 24.8
10.2

11.2

R R
22.2

A A A A A
25.2

B B B B B

One-touch fitting
P P

P, R port
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
A, B port
Applicable tubing O.D.: ø4, ø5/32"
153 ø6, ø1/4"
SY3000/5000 Base Mounted Type 45
SY5000: 9 Pins Terminal Block/Plug-in
(Station n) (Station 1) (Light/surge voltage suppressor)
C4, N3
SS5Y5-45TU- Stations D- C6, N7 -Q (9 pins)
C8, N9

71.1
71.4

42.7
7.5
Block separation button
(Push type)
U side
L3 (L4) D side
M3 DIN rail holding screw

(4.9)
(3.5)
27.5
Terminal screw DIN rail
8

41.2
PORT

PORT
B B

5.5
Note) The L1 to L4 dimensions of SS5Y5-45TU-

8
35

SOL.a

SOL.a
SOL.b

SOL.b
7

7
114.3

110.4
31.2
C4, N3

6
C4, N3
Stations U- C6, N7 -Q, SS5Y5-45TD- Stations U- C6, N7 -Q, A A A

5
C8, N9 C8, N9

4
C4, N3

3
SS5Y5-45TD- Stations D- C6, N7-Q are identical

6
2

2
C8, N9 1 COM

COM 1
C4, N3
those of SS5Y5-45TU- Stations D- C6, N7 -Q.
C8, N9

Manual override
Stations n 2 stations 3
L1 135.5 148
4
160.5
5
185.5
6
198
7 8 stations
210.5 235.5
( Press and turn to operate
and lock override.
A side: Blue
)
L2 125 137.5 150 175 187.5 200 225 B side: Yellow
L3 105 121 137 153 169 185 201 L2 5
L4 15 13.5 11.5 16 14.5 12.5 17 (Rail mounting hole pitch: 12.5)
L1
17 26 Button for DIN rail release
(Pitch) P=16
15.5

14.5
31.5

32
A A A A A R

One-touch fitting
B B B B B P

One-touch fitting (P, R port)


(A, B port) Applicable tubing O.D.: ø10, ø3/8"
Applicable tubing O.D.: ø4, ø5/32"
C4, N3 ø6, ø1/4"
SS5Y5-45TU- Stations B- C6, N7 -Q (9 pins) ø8, ø5/16"
C8, N9
U side (L4) D side
L3
DIN rail holding screw
(3.5)
(4.9)

27.5 M3
Terminal screw DIN rail
8
41.2
PORT

PORT

B B
5.5

8
35

SOL.a

SOL.a
SOL.b

SOL.b
7
7
114.3

110.4
31.2
6
6

A A A
5
5
4

4
3

3
2

2
1 COM

COM 1

Manual override

( Press and turn to operate


and lock override.
A side: Blue
)
Note) The L1 to L4 dimensions of SS5Y5-45TD- B side: Yellow
L2 5
C4, N3
Stations B- C6, N7 -Q are identical to those (Rail mounting hole pitch: 12.5)
C8, N9
L1
C4, N3
of SS5Y5-45TU- Stations B- C6, N7 -Q. (Pitch)
C8, N9
P=16 17 26 Button for DIN rail release
47
Stations n 2 stations 3 4 5 6 7 8 stations
15.5
14.5

L1 148 173
31.5

185.5 198 210.5 235.5 248


32

L2 137.5 162.5 175 187.5 200 225 237.5


R A A A A A R

L3 123 139 155 171 187 203 219 P B B B B B P


One-touch fitting
L4 12.5 17 15 13.5 11.5 16 14.5 (P, R port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
242 ø6, ø1/4" 154
ø8, ø5/16"
Type 45 Base Mounted
SY3000: 18 Pins Terminal Block/Plug-in
(Station 1)
SS5Y3-45T1U- Stations D-C4, N3
C6, N7 -Q (18 pins)
(Station n)
(Light/surge voltage suppressor)

72.7

63.3
63.2

7.5
34.5
Block separation button
(Push type)
L3 (L4)
U side D side

(C6: 3.2)
48

(N7: 7)
DIN rail holding screw
27

(3)
DIN rail
8

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

PORT

PORT

34
B B B

5.5

SOL.a

SOL.a
SOL.b

SOL.b
6

6
35

87.7
92 A A A

4
3

15.7
2

6
1 COM

COM 1
M3 Manual override
Terminal screw
( Press and turn to operate
and lock override. )
Note) The L1 to L4 dimensions of SS5Y3-45T1U- A side: Blue
B side: Yellow
Stations U- C4, N3
C6, N7 -Q are identical to those of L2 5
SS5Y3-45T1U- Stations D- C4, N3
C6, N7 -Q. (Rail mounting hole pitch: 12.5)
L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations Button for DIN rail release
L1 148 148 160.5 173 185.5 198 210.5 210.5 223 13.5 24.8

10.2
(Pitch)
11.2

L2 137.5 137.5 150 162.5 175 187.5 200 200 212.5 P = 10.5
L3 112.5 123 133.5 144 154.5 165 175.5 186 196.5
22.2

A A A A A R

25.2
L4 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13
B B B B B
One-touch fitting
P

(P, R port)
One-touch fitting Applicable tubing O.D.: ø8, ø5/16"
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45T1U- Stations B- C4, N3
C6, N7 -Q (18 pins)
L3 (L4)
U side D side
(C6: 3.2)

48
(N7: 7)

27 DIN rail holding screw


DIN rail
(3)

8
17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

PORT

PORT

34

B B B
7

SOL.a

SOL.a
SOL.b

SOL.b
92

6
35

15.7
5

87.7

A A A
5.5

4
3

3
2

2
1 COM

COM 1

M3 Manual override
Terminal screw
( Press and turn to operate
and lock override. )
A side: Blue
B side: Yellow
Stations n 2 stations 3 4 5 6 7 8 9 stations L2 5
L1 160.5 173 185.5 185.5 198 210.5 223 235.5 (Rail mounting hole pitch: 12.5)
L2 150 162.5 175 175 187.5 200 212.5 225 L1
L3 129 139.5 150 160.5 171 181.5 192 202.5 Button for DIN rail release
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 66.8 (Pitch) 13.5 24.8
10.2

11.2

Stations n 10 stations 11 12 13 14 15 16 17 stations P = 10.5


L1 248 248
22.2

R A A A A A R
260.5 273 285.5 298 310.5 310.5
25.2

L2 237.5 237.5 250 262.5 275 287.5 300 300


L3 213 223.5 234 244.5 255 265.5 276 286.5
B B B B B
P P

L4 17.5 12 13 14 15 16 17 12
One-touch fitting
One-touch fitting (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
(P, R port)
Applicable tubing O.D.: ø8, ø5/16" ø6, ø1/4"
155
SY3000/5000 Base Mounted Type 45
SY3000: 9 Pins Terminal Block/Plug-in
(Station 1)
SS5Y3-45T1D- Stations U- C4, N3
C6, N7 -Q (18 pins)
(Station n)
(Light/surge voltage suppressor)

72.7
63.3

63.2
34.5

7.5
Block separation button
(Push type)
U side D side
L3 (L4)
DIN rail holding screw

(C6: 3.2)
(N7: 7)
48
DIN rail 27

(3)
8

10 11 12 13 14 15 16 17
17 16 15 14 13 12 11 10

8
8
PORT

PORT
34
B B B

5.5
7
7
SOL.a

SOL.a

6
SOL.b

SOL.b

35
5
15.7

5
87.7
A A A

92

4
4

3
3

2
2
6

COM1
9 1 COM
9
Manual override M3

Note) The L1 to L4 dimensions of SS5Y3-45T1D- ( Press and turn to operate


and lock override.
Terminal screw
)
C4, N3
Stations D- C6, N7 -Q are identical to those of A side: Blue
B side: Yellow
SS5Y3-45T1D- Stations U- C4, N3
C6, N7 -Q. L2 (Rail mounting hole pitch: 12.5) 5
L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations (Pitch)
24.8 13.5 P = 10.5 63.8

11.2
10.2

L1 148 148 160.5 173 185.5 198 210.5 210.5 223


L2 137.5 137.5 150 162.5 175 187.5 200 200 212.5

22.2
R A A A A A
25.2

L3 112.5 123 133.5 144 154.5 165 175.5 186 196.5


L4 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 B B B B B
Button for DIN rail release
P

One-touch fitting
(P, R port) One-touch fitting
Applicable tubing O.D.: ø8, ø5/16" (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
SS5Y3-45T1D- Stations B- C4, N3
C6, N7 -Q (18 pins) ø6, ø1/4"
U side D side
L3 (L4)
48
(C6: 3.2)

DIN rail holding screw


(N7: 7)

DIN rail 27
(3)

8
17 16 15 14 13 12 11 10

10 11 12 13 14 15 16 17 8

8
PORT

PORT
34

B B B
5.5
7

7
SOL.a

SOL.a
SOL.b

SOL.b

35
15.7

5
87.7

A A A
92

4
3

3
2

2
1 COM

COM 1
9

Manual override M3
( Press and turn to operate
and lock override. ) Terminal screw

A side: Blue
B side: Yellow
L2 5
Stations n 2 stations 3 4 5 6 7 8 9 stations (Rail mounting hole pitch: 12.5)
L1 160.5 173 185.5 185.5 198 210.5 223 235.5
L1
L2 150 162.5 175 175 187.5 200 212.5 225
(Pitch)
L3 129 139.5 150 160.5 171 181.5 192 202.5 24.8 P = 10.5 13.5 66.8
11.2

10.2

L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5


Stations n 10 stations 11 12 13 14 15 16 17 stations
22.2

R A A A A A R
25.2

L1 248 248 260.5 273 285.5 298 310.5 310.5


L2 237.5 237.5 250 262.5 275 287.5 300 300
B B B B B
P P
Button for DIN rail release
L3 213 223.5 234 244.5 255 265.5 276 286.5 One-touch fitting
L4 17.5 12 13 14 15 16 17 12 (A, B port)
Applicable tubing O.D.: ø4, ø5/32" One-touch fitting
ø6, ø1/4" (P, R port)
Applicable tubing O.D.: ø8, ø5/16"

156
Type 45 Base Mounted
SY5000: 18 Pins Terminal Block/Plug-in
C4, N3
SS5Y5-45T1U- Stations D- C6, N7 -Q (18 pins)
C8, N9 (Station n) (Station 1)
(Light/surge voltage suppressor)
Block separation button
(Push type)

80.9

71.1
71.4

42.7
7.5
L3 (L4)
U side D side
48.5

(4.9)
(3.5)
27.5

41.2
PORT

PORT
B B

5.5

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

7
Note) The L1 to L4 dimensions of SS5Y5-45T1U-

110.4
31.2
6

6
C4, N3 A A A

5
Stations U- C6, N7 -Q are identical to those of
DIN rail
4

4
C8, N9 C4, N3
SS5Y5-45T1U- Stations D- C6, N7 -Q.
3

6
C8, N9
2

2
1 COM

COM 1

M3 Manual override
DIN rail holding screw Terminal screw
( Press and turn to operate
and lock override. )
A side: Blue
B side: Yellow
L2 5
(Rail mounting hole pitch: 12.5)
L1
One-touch fitting Button for DIN rail release
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
ø6, ø1/4" P=16 17 26
ø8, ø5/16"

14.5
15.5

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


31.5

32
L1 160.5 173 185.5 198 223 235.5 248 273 285.5 A A A A A R

L2 150 162.5 175 187.5 212.5 225 237.5 262.5 275 B B B B B P

L3 126 142 158 174 190 206 222 238 254 One-touch fitting
L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 (P, R port)
Applicable tubing O.D.: ø10, ø3/8"

C4, N3
SS5Y5-45T1U- Stations B- C6, N7 -Q (18 pins) U side L3 (L4) D side
C8, N9
48.5
(4.9)
(3.5)

27.5

8
41.2
PORT

PORT

B B
5.5

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2
6

A A A
5

DIN rail
4

4
3

3
2

2
1 COM

COM 1

DIN rail holding screw M3 Manual override


Terminal screw
( Press and turn to operate
and lock override. )
A side: Blue
L2 B side: Yellow 5
Stations n 2 stations 3 4 5 6 7 8 9 stations (Rail mounting hole pitch: 12.5)
L1 173 185.5 210.5 223 235.5 248 273 285.5 L1
L2 162.5 175 200 212.5 225 237.5 262.5 275 (Pitch)
Button for DIN rail release
L3 144 160 176 192 208 224 240 256 68 P=16 17 26
L4 14.5 12.5 17 15.5 13.5 12 16.5 14.5
15.5
14.5

31.5
32

Stations n 10 stations 11 12 13 14 15 16 17 stations R A A A A A R

L1 298 323 335.5 348 360.5 385.5 398 410.5


L2 287.5 312.5 325 337.5 350 375 387.5 400
P B B B B B P
One-touch fitting
(P, R port)
L3 272 288 304 320 336 352 368 384 Applicable tubing O.D.: ø10, ø3/8"
L4 13 17.5 15.5 14 12 16.5 15 13
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
157 ø6, ø1/4"
ø8, ø5/16"
SY3000/5000 Base Mounted Type 45
SY5000: 18 Pins Terminal Block/Plug-in
C4, N3 (Station n) (Station 1)
SS5Y5-45T1D- Stations U- C6, N7 -Q (18 pins) (Light/surge voltage suppressor)
C8, N9

80.9
71.1

71.4
42.7
7.5
Block separation button
(Push type)

L3 (L4)
U side D side
48.5

(4.9)
(3.5)
DIN rail holding screw 27.5
DIN rail
8

41.2
PORT

PORT
B B

5.5
35

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2

6
A A A

5
4

4
3

3
2

2
1 COM

COM 1
6

Manual override M3

( Press and turn to operate


and lock override. ) Terminal screw

A side: Blue
B side: Yellow
Note) The L1 to L4 dimensions of SS5Y5-45T1D- L2 5
C4, N3 (Rail mounting hole pitch: 12.5)
Stations D- C6, N7 are identical to those of
C8, N9
C4, N3
L1
SS5Y5-45T1D- Stations U- C6, N7.
C8, N9
26 17 (Pitch) 67 Button for DIN rail release
P=16
Stations n 2 stations 3 4 5 6 7 8 9 10 stations

15.5
14.5

L1 160.5

31.5
173 185.5 198 223 235.5 248 273 285.5
42.7

L2 150 162.5 175 187.5 212.5 225 237.5 262.5 275


R A A A A A

L3 126 142 158 174 190 206 222 238 254 P B B B B

L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 One-touch fitting One-touch fitting
(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
C4, N3 ø6, ø1/4"
SS5Y5-45T1D- Stations B- C6, N7 -Q (18 pins) ø8, ø5/16"
C8, N9 L3 (L4)
U side D side
48.5
(4.9)
(3.5)

DIN rail holding screw 27.5


DIN rail 8
41.2
PORT

PORT

B B
5.5
35

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2

A A A
5

5
4

4
3

3
2

2
1 COM

COM 1

Manual override M3

Stations n 2 stations 3 4 5 6 7 8 9 stations


( Press and turn to operate
and lock override. ) Terminal screw

A side: Blue
L1 173 185.5 210.5 223 235.5 248 273 285.5 B side: Yellow
L2 162.5 175 200 212.5 225 237.5 262.5 275 L2 5
L3 144 160 176 192 208 224 240 256 (Rail mounting hole pitch: 12.5)
L4 14.5 12.5 17 15.5 13.5 12 16.5 14.5 L1
Stations n 10 stations 11 12 13 14 15 16 17 stations (Pitch)
L1 298 323 335.5 348 360.5 385.5 398 410.5 26 P=16 17 68 Button for DIN rail release
L2 287.5 312.5 325 337.5 350 375 387.5 400
15.5

14.5

L3 272 288 304 320 336 352 368 384


31.5

32

L4 13 17.5 15.5 14 12 16.5 15 13 R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (P, R port)
ø6, ø1/4" Applicable tubing O.D.: ø10, ø3/8"
ø8, ø5/16"
242 158
Type 45 Base Mounted
SY3000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)
SS5Y3-45GU- Stations D- C4, N3
C6, N7 -Q
(Station n) (Station 1)
(Light/surge voltage suppressor)

M3
Terminal screw

63.3
39.5
7

7.5
34.5
Block separation button
(Push type)
U side D side
Applicable connector: 20 pins MIL type L3 (L4)

(C6: 3.2)
with strain relief
28.4

(N7: 7)
(Conforming to MIL-C-83503) DIN rail holding screw

(3)
DIN rail
8

34
PORT

PORT
B B B

7.7
5.5

PCW type
Note) The L1 to L4 dimensions of SS5Y3-45GU-

SOL.a
SOL.b

SOL.a
SOL.b
35
Stations U- C4, N3
C6, N7 -Q are identical to those

87.7
92
A A A

of SS5Y3-45GU- Stations D- C4, N3


C6, N7 -Q.

15.7
24VDC
+COM
- +

Triangle mark position Power supply terminals


Manual override
( marking is for 24 VDC. )
The voltage indication
( Press and turn to operate
and lock override. )
L2 5 A side: Blue
(Rail mounting hole pitch: 12.5) B side: Yellow
L1
Button for DIN rail release
11.2

(Pitch) 13.5 24.8

10.2
Stations n 2 stations 3 4 5 6 7 8 9 10 stations P = 10.5
L1 123 135.5 148 148 160.5 173 185.5 198 210.5
22.2

25.2
A A A A A

L2 112.5 125 137.5 137.5 150 162.5 175 187.5 200 G


L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5
B B B B B
P

One-touch fitting
L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
(P, R port)
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45GU- Stations B- C4, N3
C6, N7 -Q
U side D side
Applicable connector: 20 pins MIL type (L4)
with strain relief L3
(C6: 3.2)

(Conforming to MIL-C-83503)
(N7: 7)

28.4 DIN rail holding screw


(3)

DIN rail
8
34
PORT

PORT

B B B
7.7
5.5

SOL.a

SOL.a
SOL.b

SOL.b
35

87.7
92

15.7

A A A

24VDC
+COM
- +

Triangle mark position Power supply terminals Manual override

( The voltage indication


marking is for 24 VDC. ) (
Press and turn to operate
and lock override. )
L2 5 A side: Blue
Stations n 2 stations 3 4 5 6 7 8 9 10 stations (Rail mounting hole pitch: 12.5 B side: Yellow
L1 135.5 148 160.5 173 185.5 185.5 198 210.5 223 L1
L2 125 137.5 150 162.5 175 175 187.5 200 212.5
(Pitch) Button for DIN rail release
L3 108 118.5 129 139.5 150 160.5 171 181.5 192 45.8 P = 10.5 13.5 24.8
10.2

11.2

L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5


22.2
25.2

R A A A A A R

Stations n 11 stations 12 13 14 15 16 stations


L1 235.5 248 248 260.5 273 285.5 G
One-touch fitting
B B B B B

L2 225 237.5 237.5 250 262.5 275


P P

(P, R port)
L3 202.5 213 223.5 234 244.5 255 Applicable tubing O.D.: ø8, ø5/16"
L4 16.5 17.5 12 13 14 15
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
159
SY3000/5000 Base Mounted Type 45
SY3000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)
SS5Y3-45GD- Stations U- C4, N3
C6, N7 -Q (Station n) (Station 1)
(Light/surge voltage suppressor)

M3
Terminal screw

63.3
7

39.5
34.5

7.5
Note) The L1 to L4 dimensions of SS5Y3-45GD-
Stations D- C4, N3
C6, N7-Qare identical to those of
SS5Y3-45GD- Stations U-C4, N3
C6, N7-Q. Block separation button
(Push type)
U side D side
L3 (L4)
Applicable connector: 20 pins MIL type

(C6: 3.2)
DIN rail holding screw

(N7: 7)
25.6 With strain releaf
DIN rail

(3)
(Conforming to MIL-C-83503)
8

PORT

PORT
34
B B B

7.7
5.5
Triangle mark position
PCW type

SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7
A A A
92

24VDC
+COM
- +

Manual override Power supply terminals

( Press and turn to operate


and lock override. ) (Rail mounting hole pitch: 12.5)
L2 5 ( The voltage indication
marking is for 24 VDC. )
A side: Blue
B side: Yellow L1
(Pitch) Button for DIN rail release
Stations n 2 stations 3 4 5 6 7 8 9 10 stations 24.8 13.5 P = 10.5 42.8
10.2

11.2
L1 123 135.5 148 148 160.5 173 185.5 198 210.5
L2 112.5 125 137.5 137.5 150 162.5 175 187.5 200

22.2
R
25.2

A A A A A

L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 G

L4 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5


B B B B B
P

One-touch fitting
(P, R port) One-touch fitting
Applicable tubing O.D.: ø8, ø5/16" (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"

SS5Y3-45GD- Stations B- C4, N3


C6, N7 -Q
U side D side
L3 (L4)
(C6: 3.2)

Applicable connector: 20 pins MIL type


DIN rail holding screw
(N7: 7)

25.6 With strain releaf


DIN rail
(3)

(Conforming to MIL-C-83503)
8
PORT

PORT
34

B B B
5.5
7.7
SOL.a

SOL.a
SOL.b

SOL.b

35
15.7
87.7

A A A
92

24VDC
+COM
- +

Manual override Power supply terminals


Triangle mark
( Press and turn to operate
and lock override. ) L2
position
5 ( )
The voltage indication
marking is for 24 VDC.
A side: Blue (Rail mounting hole pitch: 12.5)
B side: Yellow
L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations Button for DIN rail release
(Pitch)
L1 135.5 148 160.5 173 185.5 185.5 198 210.5 223 24.8 13.5 45.8
10.2

P = 10.5
11.2

L2 125 137.5 150 162.5 175 175 187.5 200 212.5


L3 108 118.5 129 139.5 150 160.5 171 181.5 192
22.2

R R
25.2

A A A A A

L4 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 G


B B B B B

Stations n 11 stations 12 13 14 15 16 stations


P P

L1 235.5 248 248 260.5 273 285.5


One-touch fitting One-touch fitting
L2 225 237.5 237.5 250 262.5 275
(A, B port) (P, R port)Applicable tubing O.D.
L3 202.5 213 223.5 234 244.5 255 : ø8, ø5/16"
Applicable tubing O.D.: ø4, ø5/32"
L4 16.5 17.5 12 13 14 15 ø6, ø1/4"

160
Type 45 Base Mounted
SY5000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)
C4, N3 (Light/surge voltage suppressor) (Station n) (Station 1)
SS5Y5-45GU- Stations D- C6, N7 -Q
C8, N9
M3
Terminal screw

71.1
7

47.7

42.7
7.5
Note) The L1 to L4 dimensions of SS5Y5-45GU-
C4, N3
Stations U- C6, N7-Q are identical to those of
C8, N9
C4, N3 Block separation button
SS5Y5-45GU- Stations D- C6, N7 -Q.
C8, N9 (Push type)
U side D side
L3 (L4)
Applicable connector: 20 pins MIL type DIN rail holding screw

(4.9)
With strain releaf

(3.5)
28.9
(Conforming to MIL-C-83503)

41.2 8 DIN rail

PORT

PORT
B B

PCW type
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
23.2

31.2
A A A

24VDC
+COM
- +

Power supply terminals Triangle mark position Manual override

( marking is for 24 VDC. )


The voltage indication

(Rail mounting hole pitch: 12.5)


L2 5 ( Press and turn to operate
and lock override. )
A side: Blue
L1 B side: Yellow
(Pitch)
Button for DIN rail release
P = 16 17 26
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
15.5

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5


31.5

32
L2 125 137.5 150 175 187.5 200 225 237.5 250

14.5
A A A A A R

L3 105 121 137 153 169 185 201 217 233 G

L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5 One-touch fitting


B B B B B P

One-touch fitting (P, R port)


(A, B port) Applicable tubing O.D.: ø10, ø3/8"
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
C4, N3 ø8, ø5/16"
SS5Y5-45GU- Stations B- C6, N7 -Q
C8, N9
U side D side
Applicable connector: 20 pins MIL type L3 (L4)
With strain releaf
(4.9)
(3.5)

(Conforming to MIL-C-83503) 28.9


DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
23.2

31.2

A A A

24VDC
+COM
- +

Power supply terminals Triangle mark position Manual override

( The voltage indication


marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L2 5 ( Press and turn to operate
and lock override. )
A side: Blue
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 B side: Yellow
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5 (Pitch)
47 P = 16 17 26 Button for DIN rail release
L2 137.5 162.5 175 187.5 200 225 237.5 250 275
L3 123 139 155 171 187 203 219 235 251
14.5

L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17


31.5
32

15.5

R A A A A A R

Stations n 11 stations 12 13 14 15 16 stations


L1 298 310.5 323 348 360.5 373
G
P B B B B B P

L2 287.5 300 312.5 337.5 350 362.5 One-touch fitting


L3 267 283 299 315 331 347 (P, R port)
L4 15.5 13.5 12 16.5 14.5 13 Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
161 ø8, ø5/16"
SY3000/5000 Base Mounted Type 45
SY5000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)
C4, N3
SS5Y5-45GD- Stations U- C6, N7 -Q (Station n) (Station 1)
C8, N9 (Light/surge voltage suppressor)

M3
Terminal screw

71.1
7

47.6
42.7

7.5
Note) The L1 to L4 dimensions of SS5Y5-45GD-
C4, N3
Stations D- C6, N7 -Qare identical to those of
C8, N9 Block separation button
C4, N3
SS5Y5-45GD- Stations U- C6, N7-Q. (Push type)
C8, N9
U side L3 (L4) D side
Applicable connector: 20 pins MIL type

(4.9)
(3.5)
26.1 With strain releaf
DIN rail holding screw
(Conforming to MIL-C-83503)
DIN rail
8

41.2
PORT

PORT
B B
PCW type

5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
23.2
Triangle mark position
31.2

A A A

24VDC
+COM
- +

Manual override Power supply terminals


5
( Press and turn to operate
and lock override. ) (Rail mounting hole pitch: 12.5)
L2
( The voltage indication
marking is for 24 VDC. )
A side: Blue L1
B side: Yellow
26 17 (Pitch) P = 16 46 Button for DIN rail release
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
14.5

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5

31.5
32

L2 125

15.5
137.5 150 175 187.5 200 225 237.5 250
R A A A A A

L3 105 121 137 153 169 185 201 217 233 P B B B B B


G

L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


One-touch fitting One-touch fitting
(P, R port)Applicable tubing O.D. (A, B port)
: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
C4, N3 ø8, ø5/16"
SS5Y5-45GD- Stations B- C6, N7 -Q
C8, N9 U side L3 (L4) D side
DIN rail holding screw Applicable connector: 20 pins MIL type
(4.9)
(3.5)

26.1 With strain releaf


DIN rail
(Conforming to MIL-C-83503)

8
23.2 41.2
PORT

PORT

B B
5.5
35
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2

A A A

24VDC
+COM
- +

Manual override Triangle mark position Power supply terminals

( Press and turn to operate


and lock override. ) (Rail mounting hole pitch: 12.5)
L2 5 ( The voltage indication
marking is for 24 VDC.)
A side: Blue
B side: Yellow L1
26 (Pitch) P=16 17 47 Button for DIN rail release
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5
15.5
31.5

L2 137.5 162.5 175 187.5 200 225 237.5 250 275


32
14.5

L3 123
R A A A A A R

139 155 171 187 203 219 235 251


L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
G
P B B B B B P

Stations n 11 stations 12 13 14 15 16 stations


L1 298 310.5 323 348 360.5 373
One-touch fitting One-touch fitting
L2 287.5 300 312.5 337.5 350 362.5 (P, R port) (A, B port)
L3 267 283 299 315 331 347 Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
L4 15.5 13.5 12 16.5 14.5 13 ø6, ø1/4"
ø8, ø5/16"
162
Type 45
DIN Rail Manifold Exploded View
Type 45F (D-sub Connector) Manifold

r rail button
N
DI se y
U side c relea w

Posiotion when inserted


t a DIN rail holding screw

e
l on
rai utt
b
b Block separation N
DI lease
button c re

Cover

D side

i
No.
No. Description Note
SY3000 SY5000
Manifold block assembly part number differs according to an attached lead wire assembly based on the connector spec. Select an
1 Manifold block assembly appropriate part number from the table of manifold block assembly part number shown below. (Gasket 7 is supplied as an accessory.)

(Metric size) (Metric size) Metric size Inch size


2 SUP/EXH block assembly SX3000-51-2A SX5000-51-2A SY3000: P, R port with one-touch fitting for ø8 With one-touch fitting for ø 5 16"
(Inch size) (Inch size) SY5000: P, R port with one-touch fitting for ø10 With one-touch fitting for ø 3 8"
SX3000-51-16A SX5000-51-16A
3 End block assembly SX3000-52-2A-Q SX5000-52-2A-Q For D side
4 End block assembly SX3000-53-2A-Q SX5000-53-2A-Q For U side
Connector block assembly 1A 1A -1A: +COM
5-1 SX3000-64-1NA SX5000-64- 1NA
(for D-sub connector) -1NA: -COM
Connector block assembly 2A 2A
5-2 (for 26 pins flat cable)
SX3000-64- 2NA -26 SX5000-64- 2NA -26 Note)
Connector block assembly 2A 2A -2A: +COM For 24 VDC
5-3 (for 20 pins flat cable)
SX3000-64- 2NA -20 SX5000-64- 2NA -20 -2NA: -COM
Connector block assembly 2A 2A
5-4 SX3000-64- 2NA -10 SX5000-64- 2NA -10
(for 10 pins flat cable)
Connector block assembly
5-5 (for 2 to 8 stations (T, T1) terminal block)
SX3000-64-3A SX5000-64-3A
In common between +COM and –COM.
Connector block assembly
5-6 SX3000-64-8A SX5000-64-8A
(for 9 to 17 stations (T1) terminal block)
Round head M3 x 26,
6 combination screw SY3000-23-4 Matt nickel plated
7 Gasket SX3000-57-4 SX5000-57-6
8 DIN rail VZ1000-11-1-l Refer to page 118.
Note 1) The numbers 5-1 to 4 are for 24 VDC. For 12 VDC, suffix “-12V” to the end of parts number. (Example) SX3000-64-1A-12 V
Note 2) Two manifold block assemblies are necessary for the double, 3 position (Dual body type).

Style of manifold Manifold block assembly part no. Note


For 45(N)F 3
:
SX 5 000-50-3A--Q AB port SY3000 (metric size) C4: With one-touch fitting for ø4
(D-sub connector)
C6: With one-touch fitting for ø6
P
For 45(N) PG (inch size) N3: With one-touch fittign for ø 5 32"
PH
(Flat ribbon cable) N7: With one-touch fitting for ø 1 4"
SX 35 000-50-5A--Q A, B port SY5000 (metric size) C4: With one-touch fitting for ø4
For 45G C6: With one-touch fitting for ø6
PC Wiring System compatible C8: With one-touch fitting for ø8
(inch size) N3: WIth one-touch fitting for ø5 32"
For 45 TT1 N7: With one-touch fitting for ø 1 4"
SX 35 000-50-7A--Q
(Terminal block) N9: With one-touch fitting for ø 5 16"

163
SY3000/5000 Base Mounted Type 45
How to Increase Manifold Bases

1 Loosen DIN rail holding screw a fixing the manifold base until it Fig. 1
begins to turn idly. (While pressing DIN rail releasing buttons c ,
at two locations, separate the manifold base from the DIN rail.) Connector
mounting screw

2 Additional bases are to be added to the U side. Press splitting


button b of the manifold block assembly on the U side until
button b locks, and then separate the block assemblies. Fig. 2 Valve mounting
screw (2 pcs.)

3 Separate the connector block assembly in the same manner as


2 , and remove the connector mounting screw shown in Fig. 1.

4 Loosen the valve mounting screw on the U side, remove the


valve, and take out the receptacle housing. (Refer to Fig. 2.)

5
Cover
Insert the common wire (red) of the manifold block assembly to
be added into the pin insertion section (N mark) of the
receptacle housing that was taken out in 4 , mount it on the
manifold block, and mount the removed valve.
6 As shown in Fig. 3, mount the additional manifold block
Receptacle
assembly on the DIN rail on the U side. Refer to the circuit housing
diagram, and insert the lead wire (black) as shown in Fig. 4. Fig. 3

7 Press the blocks against each other until a click sound is Receptacle housing
produced, place the lead wire in the manifold block, and close
Pin insertion point
the lid without pinching the lead wire. N mark
Hook the DIN rail here and

8 While lightly holding the blocks together so that there are no


press down in the direction
of the arrow until a click
gaps between them, secure them to the DIN rail by tightening sound is heard.
the DIN rail holding screws a . (Tightening torque: 1.4 N·m)
Fig. 4
D-sub connector (45F) Flat ribbon cable (45P) Terminal block (45 TT1)
. Caution 1. Depending on the connector, there is a limit to the
number of solenoids that can be used. Manifold bases
that can be added cannot exceed the number of usable
solenoids.
Connector
2. The manifold block assembly mounting position for
additional manifold bases is always on the U side, Connector
because wires are connected to respective connectors
sequentially from the D side.
3. When DIN rail holding screw a for the end block is not
sufficiently tightened during reassembly, air leakage may
result. Before supplying air, check that there is no gap
Pin Pin Tab terminal
between blocks and that the manifold block is firmly fixed
to the DIN rail in order to ensure air supply without
leakage. Note) Note) Note)
After inserting pins, Insert pins after removing Insert tab
lightly pull lead the connectorfrom the terminals
wiresto check that main unit. After inserting completely.
pins are locked. pins, lightly pull lead
wires to check that the
pins are locked.
Fitting Assembly
Clip
Type 45 manifold permits change in the A and B port sizes by
changing the manifold block fitting assembly.
After removing the valve, remove the clip with a screwdriver, etc. For
mounting a new fitting assembly, insert it and then insert a clip until it
will not come out of the manifold block.

Fitting Assembly Part No.


Metric size Inch size
One-touch fitting for ø4 VVQ1000-50A-C4 One-touch fitting for ø5 32" VVQ1000-50A-N3 Fitting assembly
SY3000 SY3000
One-touch fitting for ø6 VVQ1000-50A-C6 One-touch fitting for ø 1 4" VVQ1000-50A-N7
One-touch fitting for ø4 VVQ1000-51A-C4 One-touch fitting for ø5 32" VVQ1000-51A-N3
SY5000 One-touch fitting for ø6 VVQ1000-51A-C6 SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø8 VVQ1000-51A-C8 One-touch fitting for ø5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust. Otherwise,
O-ring
air leakage may result. 164
5 Port Solenoid Valve
Series SY3000/5000
Base Mounted
Type 45S쏔 Stacking Type/DIN Rail Mounted
How to Order Manifold How to Order Valve Manifold Assembly (Example)

SS5Y 3 45S C 05 U C6 -Q Example


Double solenoid (24 VDC) Single solenoid (24 VDC)
Series SY3245-5FU-Q SY3140-5FU-Q
3 SY3000
5 SY5000 U side

Model
Symbol Specifications
O Without SI unit
C SYSBUS wire system (OMRON Corp.)
Q DeviceNet and CompoBus/D (OMRON Corp.) Sta
tio
R1 CompoBus/S (16 outputs) compatible (OMRON Corp.) ns
R2 CompoBus/S (8 outputs) compatible (OMRON Corp.) ....
....
T2 SI unit for ASi (8 outputs) Yellow + Black wires .. 2
T4 SI unit for ASi (4 outputs) Yellow + Black wires 1
T5 SI unit for ASi (4 outputs) Yellow wire
V CC-link System (Mitsubishi Electric Corp.)
∗ Even when the manifold is not equiped with a SI unit, the DIN
rail is long enough for future expectancy of mounting a SI unit. D side
Manifold base (5 stations)
SS5Y3-45SC-05U-C6-Q

Valve stations SS5Y3-45SC-05U-C6-Q 1 set (45S with serial unit 5 Stations


Symbol Stations Note Manifold base part number)
02 2 stations ∗ SY3140-5FU-Q 3 sets (Single solenoid part no.)
Single wining spec. ∗ SY3245-5FU-Q 1 set (Double solenoid part no.)
...
...

(Applicable up to 16 solenoid valves.)


16 16 stations
The asterisk denotes the symbol for assembly.
∗ This also includes the number of blanking plate assemblies. Prefix it to the part nos. of the solenoid valve, etc.
∗ Two stations are necessary for the double and 3 position
∗ The valve arrangement is numbered as the 1st. station from D side.
solenoid valves (Dual body type).
∗ When ordering double solenoid valves/3 position (Dual body type),
please keep in mind that they require two manifold stations.
SUP/EXH block assembly mounting position ∗ Serial unit is available only for the D-side mounting type.
Symbol Mounting position Stations
U U side 2 to 10 stations
D D side 2 to 10 stations How to Order Valve
B (Both sides) 2 to 16 stations
M Special specifications
∗ For special specifications, indicate separately by the manifold specification
sheet.
2 position single SY 3 1 4 0 5 FU -Q
A, B port size
One-touch fitting (Metric size) One-touch fitting (Inch size) Double and 3 position SY 3 2 4 5 5 FU -Q
Symbol Port size Applicable series Symbol Port size Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" Series
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1 4" SY3000 3 SY3000
M Mixed M Mixed
5 SY5000
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4" Type of actuation
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
2 2 position double
M Mixed M Mixed
3 3 position closed center
∗ In the case of mixed specifications, indicate separately on the
4 3 position exhaust center
manifold specification sheet.
5 3 position pressure center

Option Dual body type (Double and 3 position)


When a longer DIN rail is desired than the specified stations, specify the station number to be required. Rated voltage
(Max. 20 stations)
SI Unit Part No. 5 24 VDC
Symbol Specifications For SS5Y쏔-45S Symbol Specifications For SS5Y쏔-45S
C SYSBUS wire system (OMRON Corp.) EX122-STA1 R2 CompoBus/S (8 outputs) compatible (OMRON Corp.)EX122-SCS2
Q DeviceNet and CompoBus/D (OMRON Corp.) EX122-SDN1 T2 SI unit for ASi (8 outputs) Yellow + Black wiresEX122-SAS2 Manual override
R1 CompoBus/S (16 outputs) compatible (OMRON Corp.) EX122-SCS1 T4 SI unit for ASi (4 outputs) Yellow + Black wiresEX122-SAS4 - Non-locking push type
T5 SI unit for ASi (4 outputs) Yellow wire EX122-SAS5 D Push-turn locking slotted type
V CC-Link System (Mitsubishi Electric Corp.) EX122-SMJ1 E Push-turn locking lever type

165
SY3000/5000 Base Mounted Type 45S

 The serial transmission system reduces wiring work, while minimising wiring and saving space.
 16 stations max. (Specify a model with more than 9 stations by using a manifold specification sheet.)
Type C
OMRON Corporation
SYSBUS Wiring System

Name of terminal block, LED


Sta
tio
ns
....
.. 2
U side 1
LED description Detail
Lights up when transmission is normal
RUN and PLC is in operation mode.
D side T/R Flashes when transmission is normal;
ERR lights up when it is abnormal.

The total number of stations is tabulated


starting from station one on the D side.
Maximum station: Up to 16 solenoids (16
single solenoids). • SYSBUS Wire System
Master unit: Type C500-RM201

Note
Type C200H-RM201
• No. of output point: 16 points

Master station SI unit SI unit


Cable wiring

Item Specifications
External power supply 24 VDC +10%/–5% Type 3 ground Type 3 ground

Current consumption 0.1A SD, SR1, SR2, SV


(Internal unit)
0.3A SC, SQ

Type R1, R2 Type V


Type Q Mitsubishi Electric Corporation
OMRON Corporation
DeviceNet CompoBus/S compliant CC-LINK compliant
B RATE STATION NO.
0 1 0 1 0 1
PW LRUN 9 9 9
Name of terminal block, LED

2
8

8
3

3
3
7

4 4 4
6 5 6 5 6 5
LERR. SD RD
x 10 x1

24V 0V +24V 24G DA DB DG FG

LED description Detail


LED description Detail LED description Detail Lights up when transmission power;
PWR goes out when not powered.
POWER Green light is ON when the circuit is powered. Lights up when transmission is ON;
Goes out when SI unit is not online or POWER goes out when not powered. Lights up when receiving
the circuit is not powered. L RUN normal data.
Lights up for normal communication;
Green light is continuously ON when COMM goes out for abnormal SD Lights up when sending data.
SI unit is on-line and in operation. communication or waiting. RD Lights up when receiving data.
MOD/NET Red light flashes for connection time- Lights up for abnormal Lights up for transmission error and
out (minor communication error). communication; goes out for normal setting error; flashes when station
ERR
Red light is continuously ON for communication or waiting. L ERR. or transmission speed settings are
connection time-out (major communication changed during operation.
error) or online impossibility.

• CompoBus/S System • CC-Link System


• DeviceNet Master unit: C200HW-SRM21 Master unit: AJ61BT11
• OMRON Corporation: CompoBus/D System Master unit: COM1-SRM21 Master unit: A1SJ61BT11
Master station unit: C200HW-DSM21 Master unit: AJ61QBT11
Note

• No. of output point: 16 points (Type SR1) Master unit: A1SJ61QBT11


• No. of output point: 16 points No. of output point: 8 points (Type SR2) •No. of output point: 16 points

Master unit OB unit OB unit


DA DA DA
Cable wiring

Terminal Terminal
DB DB DB
resistor DG DG DG resistor
Master SLD FG FG
terminal register
Connector with

FG
With shield
Twisted pair wire
Type 3 ground Type 3 ground Type 3 ground

Pressure connector
for distribution

166
167
SY3000/5000 Base Mounted Type 45S쏔

Type T2 Type T4 Type T5

AS-i
Name of terminal block, LED

Pos. Component: Description:


1 green PWR LED green LED for AS Interface's power supply (yellow cable)
2 red ERR LED red LED for communication error (Watch-Dog)
3 green EXT LED green LED for valve power supply (24VDC PELV)
(only EX120-SAS2/4)
4 ADDR Socket for AS-i handheld programming device for address setting
socket ADDR1: for As-i slave 1 / solenoid outputs 0, 1, 2 and 3
(ADDR2 only in T2) ADDR2: for AS-i slave 2 / solenoid outputs 4, 5, 6 and 7
5 CLEAR/HOLD- CLEAR: all valves are switched OFF in case of communication error.
Switch HOLD: all the valves remain in their current ON/OFF
position in ase of communication error.
6 AS-interface-
Connection for the Connector for communication AS-i yellow ribbon cable.
yellow cable (left)
7 Connection for the
black cable Connector for external +24VDC power supply cable for the valves.
(right)
(only EX120-SAS2/4)

• free structure: line, tree or star.


• no termination resistors needed.
• no baud rate settings.
Note

• max. bus cable length: 100m (300m wit repeaters).

• 8 outputs with additional • 4 outputs with additional • 4 outputs without additional


valve power supply valve power supply valve power supply

Communication External +24VDC Communication External +24VDC Communication


connector valve power supply connector valve power supply connector
Cable wiring

Yellow cable Black cable Yellow cable Black cable Yellow cable

Plug Plug Plug- Plug


Contact
Plug
contact contact contact
contact
2 wire 2 wire 2 wire 2 wire
2 wire

168
Type 45S쏔 Base Mounted
Series SY3000: Serial Transmission Unit/Plug-in
SS5Y3-45S쏔- Stations U- C4, N3 -Q (for SI unit types C, Q, R1, R2 and V)
C6, N7
(Station n) (Station 1)
Light/surge voltage suppressor

66.1 (Note)
63.3
34.5

7.5
L3 28.8 10 (L4)
Block separation button (Note)
(Push type)

(C6:3.2)
U side D side

(N7:7)
(3)
M3 8
Terminal screw

15.7 34

PORT

PORT
B B B

5.5
6.2

SOL.a

SOL.a
SOL.b

SOL.b

64
35
45
87.7
92
A A A

Stations n 2 stations 3 4 5 6 7 8 9 10 stations Manual override


DIN rail
L1 148 160.5 173 185.5 185.5 198 210.5 223 235.5 ( Pressandandlockturnoverride.
to operate
)
L2 137.5 150 162.5 175 175 187.5 200 212.5 225 A side: Blue
DIN rail holding screw B side: Yellow
L3 81 91.5 102 112.5 123 133.5 144 154.5 165
L4 14.5 15.5 16.5 17.5 12 13 14 15 16 L2 (Note) 5
(Rail mounting hole pitch: 12.5)
Note) For SI unit types P, T2, T4, and T5, the dimensions
below increase by the values shown: L1 (Note)
(Pitch)

11.2
Button for DIN rail release 24.8 13.5 P = 10.5 32.3
SI Unit SI Unit SI Unit
L1 & L2
type height length

22.2
25.2

R A A A A A
10.2

T2, T4, T5 22.5 mm 24.3 mm 25 mm


B B B B B
P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø8, ø5/16" Applicable
tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45S쏔- Stations B- C4, N3
C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
U side D side
(C6:3.2)
(N7:7)
(3)

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


15.7 34

PORT

PORT

B B B
5.5

L1 160.5 173 185.5 198 210.5 223 223 235.5 248


SOL.a

SOL.a
SOL.b

SOL.b

35

64
45

L2 150 162.5
87.7

175 187.5 200 212.5 212.5 225 237.5


92

A A A

L3 97.5 108 118.5 129 139.5 150 160.5 171 181.5


L4 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14
Stations n 11 stations 12 13 14 15 16 stations
Manual override L1 260.5 273 285.5 285.5 298 310.5
DIN rail ( Pressandandlockturnoverride.
to operate
) L2 250 262.5
L3 192 202.5
275
213
275
223.5
287.5 300
234 244.5
A side: Blue
B side: Yellow L4 15 16 17 12 13 14
DIN rail holding screw
L2 (Note) 5 Note) For SI unit types P, T2, T4, and T5, the dimensions
(Rail mounting hole pitch: 12.5) below increase by the values shown:
L1 (Note)
L3 28.8 10 (L4) SI Unit SI Unit SI Unit
(Note) L1 & L2
(Pitch) type height length
11.2

Button for DIN rail release 24.8 P = 10.5 13.5 35.3 T2, T4, T5 22.5 mm 24.3 mm 25 mm
22.2
25.2

R A A A A A R
10.2

B B B B B
P P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø8, ø5/16" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
169
SY3000/5000 Base Mounted Type 45S:
Series SY5000: Serial Transmission Unit/Plug-in
C4, N3
SS5Y5-45S:- Stations U- C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
Light/surge voltage suppressor (Station n) (Station 1)

71.1

66.1
42.7

7.5
Block separation button L3 28.8 10 (L4)
(Push type)
DIN rail
holding screw U side D side

(3.5)

(4.9)
DIN rail
M3 8
Terminal screw

41.2

PORT

PORT
B B B

5.5
6.2

35
45
64
SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
31.2

A A A

Manual override
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 173 185.5 198 210.5 235.5 248 260.5 285.5 298
( Press and turn to operate
and lock override. )
A side: Blue
L2 162.5 175 187.5 200 225 237.5 250 275 287.5 B side: Yellow
L2 (Note) 5
L3 100 116 132 148 164 180 196 212 228
(Rail mounting hole pitch: 12.5)
L4 17.5 15.5 14 12 16.5 15 13 17.5 16
L1 (Note)
Note) For SI unit types P, T2, T4, and T5, the dimensions
(Pitch)

15.5
below increase by the values shown: Button for
DIN rail release 26 17 P = 16 41

31.5
SI Unit SI Unit SI Unit
32
14.5

L1 & L2
type height length
R A A A A A

T2, T4, T5 22.5 mm 24.3 mm 25 mm P B B B B B

One-touch fitting (A, B port)


One-touch fitting
Applicable tubing O.D.: ø4, ø5/32"
(P, R port) ø6, ø1/4"
Applicable tubing O.D.: ø10, ø3/8" ø8 , ø5/16"
C4, N3
SS5Y5-45S:- Stations B- C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
DIN rail U side D side
holding screw
(4.9)

(3.5)

DIN rail Stations n 2 stations 3 4 5 6 7 8 9 10 stations


8 L1 185.5 198 223 235.5 248 260.5 285.5 298 310.5
L2 175 187.5 212.5 225 237.5 250 275 287.5 300
41.2

L3 118 134 150 166 182 198 214 230 246


PORT

PORT

B B B
5.5

L4 14.5 13 17.5 15.5 14 12 16.5 15 13


35
45
64
SOL.a

SOL.a
SOL.b

SOL.b
110.4

Stations n 2 stations 12 13 14 15 16 stations


31.2
114.3

A A A L1 335.5 348 360.5 373 398 410.5


L2 325 337.5 350 362.5 387.5 400
L3 262 278 294 310 326 342
L4 17.5 16 14 12.5 17 15
Note) For SI unit types P, T2, T4, and T5, the dimensions
Manual override below increase by the values shown:
( Press and turn to operate
and lock override. ) SI Unit
A side: Blue SI Unit SI Unit
L1 & L2
L2 (Note) B side: Yellow 5 type height length
(Rail mounting hole pitch: 12.5) T2, T4, T5 22.5 mm 24.3 mm 25 mm
L1 (Note)
L3 28.8 10 (L4)
(Pitch) (Note)
Button for
15.5

DIN rail release 26 P = 16 17 42


31.5
32
14.5

R A A A A A R

B B B B B
One-touch fitting (A, B port)
P P

One-touch fitting Applicable tubing O.D.: ø4, ø5/32"


(P, R port) ø6, ø1/4"
Applicable tubing O.D.: ø10, ø8 , ø5/16"
170
5 Port Solenoid Valve
Series SY3000/5000
Base Mounted
Stacking Type/DIN Rail Mounted
Type 45S1쏔 Serial Transmission Unit (Separate type)
How to Order Manifold

SS5Y 3 45S1 C D 05 U C4 -Q
Series Option
3 SY3000 When a longer DIN rail is desired than the specified
5 SY5000 stations, specify the station number to be required.
(Max. 20 stations)

A, B port size
Model One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Specifications Symbol Port size Applicable series Symbol Port size Applicable series
O Without SI unit C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C SYSBUS wire system (OMRON Corp.) C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
Q DeviceNet and CompoBus/D (OMRON Corp.) M Mixed M Mixed
R1 CompoBus/S (16 outputs) compatible (OMRON Corp.) C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
R2 CompoBus/S (8 outputs) compatible (OMRON Corp.) C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
T2 SI unit for ASi (8 outputs) Yellow + Black wires C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
T4 SI unit for ASi (4 outputs) Yellow + Black wires M Mixed M Mixed
T5 SI unit for ASi (4 outputs) Yellow wire ∗ In the case of mixed specifications, indicate separately on the manifold
V CC-Link System (Mitsubishi Electric Corp.) specification sheet.

SUP/EXH block assembly mounting position


• Even when the manifold is not equipped Symbol Mounting position Stations
with a SI unit, the DIN rail length is long
U U side 2 to 10 stations
enough for future expectancy of mounting
D D side 2 to 10 stations
a SI unit. When a shorter rail is required
(same as type 45쏔), suffix “0” in the B Both sides 2 to 16 stations
optional blank at the end of part number. M Special specifications
• For SI unit specifications, Refer to pages ∗ For special specifications, indicate
166 through to 168. separately by the manifold specification
sheet.

Valve stations
Symbol Stations Note
02 2 stations Single wiring spec.
...

...

(Applicable up to 16
16 16 stations solenoid valves.)
SI unit mounting position
∗ This also includes the number of
Symbol Mounting position blanking plate assemblies.
U U side ∗ Two stations are necessary for the
D D side double, and 3 position solenoid valves
(Dual body type).

SI Unit Part No.


Symbol Specifications For SS5Y첸-45S1 Symbol Specifications: For SS5Y첸-45S1
C SYSBUS wire system (OMRON Corp.) EX121-STA1 R2 CompoBus/S (8 outputs) compatible (OMRON Corp.) EX121-SCS2
Q DeviceNet and CompoBus/D (OMRON Corp.) EX121-SDN1 T2 SI unit for ASi (8 outputs) Yellow + Black wires EX121-SAS2
R1 CompoBus/S (16 outputs) compatible (OMRON Corp.) EX121-SCS1 T4 SI unit for ASi (4 outputs) Yellow + Black wires EX121-SAS4
T5 SI unit for ASi (4 outputs) Yellow wire EX121-SAS5
V CC-Link System (Mitsubishi Electric Corp.) EX121-SMJ1

∗ For terminal LED descriptions and cable wiring, etc. for each SI unit, refer to pages 166 through 168.

For external pilot specifications and built-in silencer, refer to page 207.

171
SY3000/5000 Base Mounted Type 45S1쏔
How to Order Valve Manifold Assembly (Example) How to Order Valve

Example 2 position single SY 3 1 4 0 5 FU -Q


Double solenoid (24 VDC)
SY3245-5FU-Q
Single solenoid (24 VDC)
SY3140-5FU-Q
Double and 3 position SY 3 2 4 5 5 FU -Q
U side Series
3 SY3000
5 SY5000

Type of actuation
Sta
tio 2 2 position double
ns
.... 3 3 position closed center
....
.. 2 4 3 position exhaust center
1
5 3 position pressure center

Dual body type (Double and 3 position)

D side Rated voltage


Manifold base (5 stations) 5 24 VDC
SS5Y3-45S1BD-05U-C6-Q

Manual override
S5Y3-45S1CD-05U-C6-Q 1 set (Type 45S1 with serial unit 5 - Non-locking push type
station manifold base part no.)
∗ SY3140-5FU-Q 3 sets (Single solenoid part no.)
D Push-turn locking slotted type
∗ SY3245-5FU-Q 1 set (Double solenoid part no.) E Push-turn locking lever type

The asterisk denotes the symbol for assembly.


Prefix it to the part nos. of the solenoid valve, etc.
• The valve arrangement is numbered as the 1st. station from D side
regardless of the mounting position of SI unit.
• When ordering double solenoid valves/3 position (Dual body type), please
keep in mind that they require two manifold stations.

172
Type 45S1쏔 Base Mounted
SY3000: Serial Transmission Unit/Plug-in

SS5Y3-45S1쏔U- Stations D-C4, N3


C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
(Station n) (Station 1)
Light/surge voltage suppressor

63.3 (Note)
Note) The L1 to L4 dimensions of SS5Y3-45S1쏔U-

66.1
Stations U- C4, N3 are identical to those of
C6, N7

34.5
SS5Y3-45S1쏔U- Stations D- C4, N3 .

7.5
C6, N7

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


L1 160.5 173 185.5 198 198 210.5 223 235.5 248 10 30.8 (Note) L3 (L4)
M3
L2 150 162.5 175 187.5 187.5 200 212.5 225 237.5

(C6:3.2)
Block separation button D side Terminal screw
U side

(N7:7)
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 (Push type)
DIN rail holding screw

(3)
L4 14 15 16 17 12 13 14 15 16
DIN rail

6.2
Note) For SI unit types N, P, T2, T4, T5 and Y,
the dimensions below increase by the 8

34
PORT

PORT
B B B
values shown
5.5

SOL.a

SOL.a
SOL.b

SOL.b
64
35

A A A
92

87.7
SI Unit SI Unit SI Unit
L1 & L2
type height length

15.7
T2, T4, T5 22.5 mm 24.3 mm 25 mm

Manual override

( Press and turn to operate


and lock override. ) L2 (Note)
(Rail mounting hole pitch: 12.5)
A side: Blue
B side: Yellow L1 (Note)
(Pitch) Button for DIN rail release
P = 10.5 13.5 24.8

10.2
22.2

A A A A A R

25.2
11.2

B B B B B
P
One-touch fitting
(P, R port)
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45S1쏔U- Stations B- C4, N3
C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
(C6:3.2)

U side D side
(N7:7)

DIN rail holding screw


(3)

DIN rail

8
PORT

PORT

B B B
34
5.5

SOL.a

SOL.a
SOL.b

SOL.b
64
35

15.7
87.7

A A A
92

Stations n 2 stations 3 4 5 6 7 8 9 10 stations Manual override


L1 173 185.5 198 210.5 223 235.5 235.5 248 260.5
L2 162.5 175 187.5 200 212.5 225 225 237.5 250
( Press and turn to operate
and lock override. )
A side: Blue
L3 108 118.5 129 139.5 150 160.5 171 181.5 192 B side: Yellow L2 (Note)
L4 12 13 14 15 16 17 12 13 14 (Rail mounting hole pitch: 12.5)
Stations n 11 stations 12 13 14 15 16 stations L1 (Note)
L1 273 285.5 298 298 310.5 323 Button for DIN rail release
L2 262.5 275 287.5 287.5 300 312.5 10 30.8 L3 (L4)
L3 202.5 213 223.5 234 244.5 255 (Note) (Pitch)
11.2

L4 15 16 17 11.5 12.5 13.5


10.2

45.8 P = 10.5 13.5 24.8


Note) Width of SI unit applicable to “E”:
22.2

R A A A A A R
Matsushita Electric Works, Ltd. and “G”:
25.2

Rockwell Automation, Inc. (Allen-Bradley)


widens to 24.3 mm. For further P
B B B B B
P

information, please consult with SMC. One-touch fitting


(P, R port)
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(A, B port)
173 Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SY3000/5000 Base Mounted Type 45S1쏔
SY3000: Serial Transmission Unit/Plug-in
SS5Y3-45S1쏔D- Stations U- C4, N3 -Q (for SI unit types C, Q, R1, R2 and V)
C6, N7

(Station n) (Station 1)
Light/surge voltage suppressor

Note) The L1 to L4 dimensions of SS5Y3-45S1쏔D-

66.1 (Note)
Stations D- C4, N3 are identical to those of

63.3
C6, N7
SS5Y3-45S1쏔D- Stations U- C4, N3
C6, N7 .

34.5

7.5
Block separation button L3 30.8 10 (L4)
(Push type)
(Note)

(C6:3.2)
(N7:7)
U side D side
M3

(3)
Terminal screw 8

15.7 34

PORT

PORT
B B B

5.5
6.2

SOL.a

SOL.a
SOL.b

SOL.b

35

64
45
87.7
92
A A A

DIN rail Manual override


Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 160.5 173 185.5 198 198 210.5 223 235.5 248
DIN rail holding screw
Press and turn to operate
and lock override. ( )
A side: Blue
L2 150 162.5 175 187.5 187.5 200 212.5 225 237.5 B side: Yellow
L3 91.5 102 112.5 123 133.5 144 154.5 165 175.5 L2 (Note) 5
L4 14 15 16 17 12 13 14 15 16 (Rail mounting hole pitch: 12.5)
Note) For SI unit types P, T2, T4, and T5, the dimensions L1 (Note)
below increase by the values shown: Button for DIN rail release
(Pitch)

11.2
10.2

24.8 13.5 P = 10.5 42.8

22.2
SI Unit SI Unit SI Unit
25.2

R A A A A A

L1 & L2
type height length
B B B B B

T2, T4, T5 22.5 mm 24.3 mm 25 mm One-touch fitting


P

(P, R port)
Applicable tubing O.D.: ø8, ø5/16"

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
SS5Y3-45S1쏔D- Stations B- C4, N3
C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
(C6:3.2)
(N7:7)

U side D side
(3)

Stations n 2 stations 3 4 5 6 7 8 9 10 stations 8


L1 173 185.5 198 210.5 223 235.5 235.5 248 260.5
15.7 34

PORT

PORT

L2 162.5 175 187.5 200 212.5 225 225 237.5 250 B B B


5.5

L3 108 118.5 129 139.5 150 160.5 171 181.5


SOL.a

SOL.a
SOL.b

SOL.b

192
35

64
45
87.7
92

A A A

L4 12 13 14 15 16 17 12 13 14
Stations n 11 stations 12 13 14 15 16 stations
L1 273 285.5 298 298 310.5 323
L2 262.5 275 287.5 287.5 300 312.5
DIN rail Manual override
L3 202.5 213 223.5 234 244.5 255
L4 15 16 17 11.5 12.5 13.5 DIN rail holding screw Press and turn to operate
and lock override. ( )
Note) For SI unit types P, T2, T4, and T5, the dimensions A side: Blue
below increase by the values shown: B side: Yellow
L2 (Note) 5
(Rail mounting hole pitch: 12.5)
L1 (Note)
SI Unit SI Unit SI Unit
L1 & L2
type height length Button for DIN rail release L3 30.8 10 (L4)
T2, T4, T5 22.5 mm 24.3 mm 25 mm (Pitch) (Note)
10.2
11.2

24.8 P = 10.5 13.5 45.8


22.2

25.2

R A A A A A R

B B B B B
P P

One-touch fitting
(P, R port)
Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
174
Type 45S1쏔 Base Mounted
SY5000: Serial Transmission Unit/Plug-in
C4, N3
SS5Y5-45S1쏔U- Stations D- C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
(Station n) (Station 1)
Light/surge voltage suppressor

66.1 (Note)
Note) The L1 to L4 dimensions of SS5Y5-45S1쏔U-

71.1
C4, N3
Stations U- C6, N7 are identical to those of

42.7
7.5
C8, N9 C4, N3
SS5Y5-45S1쏔U- Stations D- C6, N7 .
C8, N9

Stations n 2 stations 3 4 5 6 7 8 9 10 stations 10 30.8 L3 (L4)


L1 173 185.5 210.5 223 235.5 260.5 273 285.5 298 (Note) Block separation button
L2 162.5 175 200 212.5 225 250 262.5 275 287.5 (Push type)
M3

(4.9)
U side

(3.5)
L3 105 121 137 153 169 185 201 217 233 D side
8 Terminal screw
L4 13.5 12 16.5 14.5 13 17.5 15.5 14 12 DIN rail

6.2
Note) For SI unit types N, P, T2, T4, T5

41.2
and Y, the dimensions below

PORT

PORT
B B B
5.5
increase by the values shown:
45

SOL.a

SOL.a
SOL.b

SOL.b
64

35
114.3

110.4
31.2
A A A

SI Unit SI Unit SI Unit


L1 & L2
type height length
T2, T4, T5 22.5 mm 24.3 mm 25 mm

DIN rail holding screw


Manual override L2 (Note) 5
( Press and turn to operate
and lock override. ) (Rail mounting hole pitch: 12.5)
A side: Blue L1 (Note)
B side: Yellow Button for
DIN rail release
(Pitch)

14.5
15.5

P = 16 17 26
31.5

32
A A A A A R

B B B B B P

One-touch fitting One-touch fitting


(A, B port) (P, R port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø10, ø3/8"
ø6, ø1/4"
ø8, ø5/16"
C4, N3
SS5Y5-45S1쏔U- Stations B-C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
U side D side
(4.9)

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


(3.5)

L1 198 210.5 223 235.5 260.5 273 285.5 310.5 323 8 DIN rail
L2 187.5 200 212.5 225 250 262.5 275 300 312.5
L3 123 139 155 171 187 203 219 235 251
41.2
PORT

PORT

B B B
L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5
5.5
45

SOL.a

SOL.a
SOL.b

SOL.b
64

35

Stations n 11 stations 12 13 14 15 16 stations


114.3

110.4
31.2

L1 335.5 348 373 385.5 398 410.5 A A A

L2 325 337.5 362.5 375 387.5 400


L3 267 283 299 315 331 347
L4 14 12 16.5 15 13 11.5
DIN rail
Note) For SI unit types N, P, T2, T4, T5 holding
and Y, the dimensions below screw
increase by the values shown: Manual override
L2 (Note) 5
( Press and turn to operate
and lock override. ) (Rail mounting hole pitch: 12.5)
A side: Blue L1 (Note)
B side: Yellow
10 30.8 L3 (L4)
(Note) DIN rail holding screw
SI Unit SI Unit SI Unit (Pitch)
14.5

15.5

L1 & L2 47 P = 16 17 26
type height length
T2, T4, T5 22.5 mm 24.3 mm 25 mm
31.5
32

R A A A A A R

P B B B B B P
One-touch fitting
One-touch fitting
(A, B port)
(P, R port)
Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8"
ø6, ø1/4"
ø8, ø5/16"

175
SY3000/5000 Base Mounted Type 45S1쏔
SY5000: Serial Transmission Unit/Plug-in

C4, N3
SS5Y5-45S1쏔D- Stations U-C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
(Station n) (Station 1)
Light/surge voltage suppressor
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 173 185.5 210.5 223 235.5 260.5 273 285.5 298
L2 162.5 175 200 212.5 225 250 262.5 275 287.5

71.1

66.1
L3 105 121 137 153 169 185 201 217 233

42.7
L4 13.5 12 16.5 14.5 13 17.5 15.5 14 12

7.5
Note) For SI unit types N, P, T2, T4, T5 and Y,
the dimensions below increase by the
values shown: Block separation button L3 30.8 10 (L4)
(Push type) (Note)
SI Unit SI Unit SI Unit M3 U side D side

(4.9)
(3.5)
L1 & L2
type height length Terminal screw
DIN rail
T2, T4, T5 22.5 mm 24.3 mm 25 mm
8
41.2 B B B

PORT

PORT

5.5
6.2

35

64
45
114.3

SOL.a

SOL.a
SOL.b

SOL.b
110.4
31.2

A A A

Manual override

( Press and turn to operate


and lock override. )
DIN rail holding screw L2 (Note) 5 A side: Blue
B side: Yellow
(Rail mounting hole pitch: 12.5)
L1 (Note)
Button for DIN rail release
14.5

15.5
26 17 (Pitch) 46
P = 16

31.5
32

Note) The L1 to L4 dimensions of SS5Y5-45S1쏔D-


A A A A A

C4, N3
Stations D- C6, N7 are identical to those of P B B B B B

C8, N9 One-touch fitting


One-touch fitting
SS5Y5-45S1쏔D- Stations U- C6, N7 .
C4, N3

C8, N9 (P, R port) (A, B port)


Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
C4, N3
SS5Y5-45S1쏔D- Stations B-C6, N7 -Q (for SI unit types C, Q, R1, R2 and V)
C8, N9
U side D side
DIN rail holding screw
(4.9)

(3.5)

DIN rail
8
41.2

B B B
PORT

PORT

5.5

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


35

64
45
114.3

SOL.a

SOL.a
SOL.b

SOL.b
110.4

L1 198 210.5 223 235.5 260.5 273 285.5 310.5 323


31.2

L2 187.5 200 212.5 225 250 262.5 275 300 312.5 A A A

L3 123 139 155 171 187 203 219 235 251


L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5
Stations n 11 stations 12 13 14 15 16 stations
L1 335.5 348 373 385.5 398 410.5 Manual override
L2 325 337.5 362.5 375 387.5 400
L3 267 283 299 315 331 347
( Press and turn to operate
and lock override. ) L2 (Note)
(Rail mounting hole pitch: 12.5)
5
A side: Blue
L4 14 12 16.5 15 13 11.5 B side: Yellow L1 (Note)
Note) For SI unit types N, P, T2, T4, T5 and Y, L3 30.8 10 (L4)
the dimensions below increase by the Button for DIN rail release (Note)
(Pitch)
values shown:
14.5
15.5

26 P = 16 17 47

SI Unit SI Unit SI Unit


L1 & L2
31.5

32

type height length R A A A A A R

T2, T4, T5 22.5 mm 24.3 mm 25 mm


P B B B B B P
One-touch fitting
One-touch fitting
(A, B port)
(P, R port)
Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8"
ø6, ø1/4"
ø8, ø5/16"
176
3 Port Valve
Series SY300/500
Mixed Mounting Type on 5 Port Valve Manifold
3 port valve can be mounted on manifold for 5 port valve.

Applications How to Order Valve Manifold Assembly (Example)

Possible to be mounted on all kinds of manifolds for Series Example


SY3000/5000. 5 port valve: Double solenoid
Refer to “How to Order Manifold” for the details. Cylinder port size
SY3220-5G-C6-Q (2 sets)
C6: With one-touch fitting for ø6
3 port valve: Single solenoid (N.C.)
5 port valve: Single solenoid SY313-5G-C6-Q (2 sets)
SY3120-5G-C6-Q (1 set)
Manifold base (5 stations)
–+
–+
SS5Y3-20-05-Q
–+
EB
–+
–+ P
EA

SS5Y3-20-05-Q 1 set (Type 20, 5 station manifold base part no.)


∗ SY313-5G-C6-Q 2 sets (3 port valve, type NC part no.)
∗ SY3120-5G-C6-Q 1 set (5 port valve, single solenoid part no.)
∗ SY3220-5G-C6-Q 2 sets (5 port valve, double solenoid part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number. In
the case of complex arrangement, specify them on the manifold specification
sheet.

177
SY300/500

Body Ported/How to Order Valve

Individual Wiring: For SS5Y3


5 -20

SY 5 1 3 5 L 01 -Q
Thread type
Series - Rc
3 SY300 F G
5 SY500 N NPT
Type of actuation T NPTF
∗ Except for M5
1 Normally closed (N.C.)
2 Normally open (N.O.) A port size
Thread piping
Solenoid type Symbol Port size Applicable series
- Single solenoid M5 M5 SY300
D Double solenoid 01 1 8 SY500
One-touch fitting (Metric size) One-touch fitting (Inch size)
Coil specifications Symbol Port size Applicable series Symbol Port size Applicable series
- Standard C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
T With power saving circuit (24 VDC, 12 VDC only) SY300 SY300
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
∗ Power saving circuit is not available in the C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
case of D, DO or W type. SY500 SY500
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"

Rated voltage Manual override


For DC For AC - Non-locking push type
5 24 VDC 1 100 VAC D Push-turn locking slotted type
6 12 VDC 2 200 VAC E Push-turn locking lever type
V 6 VDC 3 110 VAC [115 VAC]
S 5 VDC 4 220 VAC [230 VAC] Light/surge voltage suppressor
R 3 VDC
Electrical entry for G, H, L, M, W Electrical entry for D
∗ DC specifications of Type D and DO is
- Without light/surge voltage suppressor (SY500 only)
only available with 12 and 24 VDC.
S With surge voltage suppressor - Without light/surge voltage suppressor
∗ AC specification is only available with
D and DO type. Z With light/surge voltage suppressor S With surge voltage suppressor
R With surge voltage suppressor (Non-polar type) Z With light/surge voltage suppressor
U With light/surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
∗ Power saving circuit is only ∗ For AC voltage valves
Electrical entry
available in the "Z" type. there is no “S” option. It
24, 12 VDC/ is already built-in to the
24, 12,
24, 12, 6, 5, 3 VDC 100, 110, rectifier circuit.
6, 5, 3 VDC
200, 220 VAC
L plug M plug DIN terminal
Grommet M8 connector ∗
connector connector (SY5000 only)
G: Lead wire L: With lead M: With lead D: With WO: Without
length wire (Length wire (Length connector connector
300 mm 300 mm) 300 mm) DO:Without cable
H: Lead wire LN: Without lead MN: Without lead connector W: With
length wire wire connector
600 mm LO: Without MO: Without cable
connector connector Note 1)

∗ LN, MN type: with 2 sockets.


∗ For DIN terminal of SY300 series, refer to back page 10.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former
DIN43650C) is also available. For details, refer to page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also
available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank
referring to back page 13.

Note) When placing an order for body ported solenoid valve as a single
unit, mounting bolt for manifold and gasket are not attached. Order
them separately, if necessary.
(For details, refer to page 56.)

178
SY300/500

Body Ported/How to Order Valve


Flat ribbon cable: SS5Y3
5 -20P
Light/surge voltage suppressor A port size
Thread piping
Z With light/surge voltage suppressor
Symbol Port size Applicable series
With light/surge voltage suppressor M5 M5 SY300
U
(Non-polar type) 1 8
01 SY500
Note) Z: Positive common specifications only.
One-touch fitting (Metric size) One-touch fitting (Inch size)
Rated voltage Symbol Port size Applicable series Symbol Port size Applicable series
5 24 VDC C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
SY300 SY300
6 12 VDC C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
SY500 SY500
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"

For DC: SY 5 1 3 5 LO Z -Q
Thread type
- Rc
Series
F G
3 SY300
N NPT
5 SY500
T NPTF ∗ Except for M5
Type of actuation Manual override
- Non-locking push type
1 Normally closed (N.C.)
D Push-turn locking slotted type
2 Normally open (N.C.)
E Push-turn locking lever type
Solenoid type
- Single solenoid
D Double solenoid

Base Mounted/How to Order Valve


Individual wiring: For SS5Y3
5 -41/42/45

SY 5 1 5 5 L -Q
Series Manual override
3 SY300 - Non-locking push type
5 SY500 D Push-turn locking slotted type
Type of actuation E Push-turn locking lever type
1 Normally closed (N.C.)
Light/surge voltage suppressor
2 Normally open (N.C.)
Electrical entry for G, H, L, M, W Electrical entry for D (SY500 only)
Solenoid type - Without light/surge voltage suppressor - Without light/surge voltage suppressor
- Single solenoid S With surge voltage suppressor S With surge voltage suppressor
D Double solenoid Z With light/surge voltage suppressor Z With light/surge voltage suppressor
Pilot type R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
- Internal pilot U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no
R External pilot ∗ Power saving circuit is only available “S” option. It is already built-in to
in the "Z" type. the rectifier circuit.
∗ External pilot is
not available for
Type 41 manifold.
Electrical entry
Coil specifications 24, 12 VDC/
Nil Standard 24, 12,
24, 12, 6, 5, 3 VDC 100, 110,
T With power saving circuit (24 VDC, 12 VDC only) 6, 5, 3 VDC
200, 220 VAC
∗ Power saving circuit is not available L plug M plug DIN terminal
Grommet (SY5000 only) M8 connector ∗
in the case of D, DO or W type. connector connector
G: Lead wire L: With lead wire M: With lead wire WO: Without
Rated voltage D: With connector
For DC AC length 300 mm (Length 300 mm) (Length 300 mm) connector cable
DO: Without
H: Lead wire LN: Without lead wire MN: Without lead wire W: With connector
5 24 VDC 1 100 VAC connector
length 600 mm LO: Without connector MO: Without connector cable Note 1)
6 12 VDC 2 200 VAC ∗ LN, MN type: with 2 sockets.
V 6 VDC 3 110 VAC [115 VAC] ∗ For DIN terminal of SY300 series, refer to back page 10.
S 5 VDC 4 220 VAC [230 VAC] ∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available.
R 3 VDC For details, refer to page 210.
∗ For connector cable of M8 connector, refer to back page 12.
∗ DC specifications of Type D and DO is only available
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For details, see page 211.
with 12 and 24 VDC.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back page 13.
∗ AC specification is only available with D and DO type.

179
SY300/500

Base Mounted/How to Order Valve

Flat ribbon cable:


For SS5Y 35 -41P/42P/45-A
Connector box type:

Rated voltage Light/surge voltage suppressor


5 24 VDC With light/surge voltage
Z suppressor
6 12 VDC
With light/surge voltage
U suppressor
41P/42P -Q Note) Z: Positive common
45-A
For DC: SY 5 1 5 5 LO Z (Non-polar type)

specifications only.

Series Manual override


3 SY300 - Non-locking push type
5 SY500 D Push-turn locking slotted type
E Push-turn locking lever type
Type of actuation
1 Normally closed (N.C.)
2 Normally open (N.C.)

Solenoid type Pilot type


- Single solenoid - Internal pilot
D Double solenoid R External pilot
∗ External pilot is not
available for Type 41P
manifold.

Plug-in: For SS5Y3


5 -45

Single solenoid: SY 5 1 5 5 FU -Q
Double solenoid: SY 5 1 5C 5 FU -Q
Series Manual override
3 SY300 - Non-locking push type
5 SY500 D Push-turn locking slotted type
E Push-turn locking lever type
Type of actuation
1 Normally closed (N.C.) Rated voltage
2 Normally open (N.C.) For DC
5 24 VDC
6 12 VDC

Dual body type Pilot type


- Internal pilot
∗ When ordering double solenoid
R External pilot
valves (Dual body type), please
keep in mind that they require two
manifold stations.

180
SY300/500

Construction

JIS Symbol Normally closed (N.C.) JIS Symbol Normally closed (N.C.)
Single Double
Single solenoid Double solenoid

A A

w u w u
y e y

r EA P t q r EA P t q
JIS Symbol Normally open (N.O.) JIS Symbol Normally open (N.O.)
Single Double
Single solenoid Double solenoid

A A

w u w u
y e y

r EA P t q r EA P t q
Component Parts Replacement Parts
No. Description Material Note No. Description No.
Aluminum die-casted 6 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 5.
1 Body White
(SY3000: Zinc die-casted) 7 M5 port block assembly Refer to “How to Order Port Block Assembly” below.
2 Adapter plate Resin White
3 End plate Resin White
4 Piston Resin –
5 Spool valve assembly Aluminum, H-NBR –

How to Order M5 Port Block Assembly


One-touch Mounting
SY 00 2A Thread type fitting assembly screw
- Rc
Series F G
3 Series SY300 N NPT ∗ Only replacement of the fittings assembly is
5 Series SY500 T NPTF possible.
∗ Except for M5
A, B port size Metric size
Thread piping One-touch fitting (Inch size) One-touch fitting for ø4 VVQ1000-50A-C4
Symbol Port size Applicable series
Symbol Port size Applicable series SY300
One-touch fitting for ø6 VVQ1000-50A-C6
M5 M5 SY300 N3 One-touch fitting for ø 5 32" One-touch fitting for ø4 VVQ1000-51A-C4
1 8
SY300
01 SY500 N7 One-touch fitting for ø 1 4" SY500 One-touch fitting for ø6 VVQ1000-51A-C6
One-touch fitting (Metric size) N3 One-touch fitting for ø 32 5 " One-touch fitting for ø8 VVQ1000-51A-C8
Symbol Port size Applicable series N7 One-touch fitting for ø 4" SY500
1
Port block assembly Inch size
N9 One-touch fitting for ø 5 16"
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
SY300 Caution (cassette type)
SY300
One-touch fitting for ø 5 32" VVQ1000-50A-N3
One-touch fitting for ø 1 4" VVQ1000-50A-N7
C4 One-touch fitting for ø4 Mounting screw tightening torques One-touch fitting for ø 5 32" VVQ1000-51A-N3
C6 One-touch fitting for ø6 SY500
SY300 (M2) : 0.12 N·m SY500 One-touch fitting for ø 1 4" VVQ1000-51A-N7
C8 One-touch fitting for ø8 One-touch fitting for ø 5 16"
SY500 (M3) : 0.6 N·m VVQ1000-51A-N9

181
SY300/500

Specifications

Dimensions, specifications, solenoid specifications, response time and effective area are the same as 5 port valve.

Weight

Series SY300 Series SY500


Weight (g) Weight (g)
Valve model Type of actuation Valve model Type of actuation
Grommet L, M plug connector Grommet L, M plug connector DIN terminal
Single 51 53 Single 69 72 93
SY33--M5 SY53--01
Double 68 74 Double 87 93 135
Single 56 59 Single 82 82 103
SY33-- C4
N3 SY53-- C4
N3
Double 74 79 Double 100 102 144
C6 Single 54 57 C6 Single 79 77 98
SY33-- N7 SY53-- N7
Double 72 77 Double 97 98 140
Single 47 50 C8 Single 75 84 105
SY35- SY53-- N9
Double 65 70 Double 93 105 147
Single 55 58 79
SY55-
Double 73 78 120

182
5 Port Air Operated Valve
Series SYA3000/5000/7000
How to Order

A, B port size Thread type


Thread piping One-touch fitting (Inch size) - Rc
Symbol Port size Applicable series Symbol Port size Applicable series F G
M5 M5 SYA3000 N3 One-touch fitting for ø5 32" N NPT
SYA3000
01 1 8 SYA5000 N7 One-touch fitting for ø1 4" T NPTF
02 1 4 SYA7000 N3 One-touch fitting for ø 32"
5
∗ Except for M5
One-touch fitting (Metric size) N7 One-touch fitting for ø1 4" SYA5000
N9 One-touch fitting for ø5 16"
Bracket
Symbol Port size Applicable series - Without bracket
C4 One-touch fitting for ø4 N7 One-touch fitting for ø1 4"
SYA3000 SYA7000 With foot bracket
C6 One-touch fitting for ø6 N9 One-touch fitting for ø5 16" F1
(2 position single only)
C4 One-touch fitting for ø4 F2 With side bracket
C6 One-touch fitting for ø6 SYA5000 Series
C8 One-touch fitting for ø8 3 SYA3000
C8 One-touch fitting for ø8 5 SYA5000
SYA7000 7 SYA7000
C10 One-touch fitting for ø10

Body ported SYA 5 1 20 C6


Base mounted SYA 5 1 40
Series P, R port
3 SYA3000 thread type
5 SYA5000 - Rc
F G
Base mounted SYA 7 1 40 N
T
NPT
NPTF
P, R port
Type of actuation thread type
2 position single - Rc
F G
1 Port size
N NPT
Symbol Port size Applicable series
T NPTF
- Without sub-plate
2 position double 18
Port size 01 SYA3000
With sub-plate
2
Symbol Port size 14
02 SYA5000
- Without sub-plate With sub-plate
3 position closed center Without sub-plate
00
(Pilot port: expect for RC)
3 14
02
With sub-plate
38
3 position exhaust center 03
With sub-plate
4

3 position pressure center

183
SYA3000/5000/7000

Specifications

Fluid Air
Operating 2 position single 0.15 to 0.7
pressure range 2 position double 0.1 to 0.7
MPa 3 position 0.2 to 0.7
Pilot pressure 2 position single (0.7 x P + 0.1) to 0.7P: Operating pressure range
range Note 1) 2 position double 0.1 to 0.7
MPa 3 position 0.2 to 0.7
Ambient and fluid temperature (°C) Max. 60
Manual override (Manual operation) Non-locking push type
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note 2) 150/30
Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to supply
port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The
test was performed on the axis and right angle directions of the main valve and
armature, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 8.3 and 2000 Hz. Test was
performed to axis and right angle directions of the main valve and armature
when pilot signal is ON and OFF. (Value in the initial state)

Caution
For Safety Instructions and Common Precautions,
refer to back page 1 through to 15.

How to Order Manifold Base Pilot Pressure Range


Same manifolds as series SY (Non plug-in style) are prepared.
(Single pilot)
(For 20, 41, 42 and 45 Types)

Pilot pressure
3 3 range
SS5YA 5 – Fill the same as SS5Y . 5
7 7
Pilot pressure MPa

∗ Specify
the part numbers for valves and options together
beneath the manifold base part number.
<Example>
SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.)
∗ SYA5140 1 set (Single air operated valve part no.)
∗ SYA5240 1 set (Double air operated valve part no.)
∗ SY5000-26-20A-Q 1 set (Blanking plate assembly part no.)
Operating pressure MPa
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Note) When single body ported air operated valves are ordered, manifold
mounting bolts and gaskets are not included. Order them separately if
necessary.
(For details, refer to page 56.)

184
SYA3000/5000/7000

Flow Characteristics/Weight

Model/Series SYA320 (Body ported)


Pilot Flow characteristics
Type of Port size Weight
Valve model port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
actuation (Nominal size) P, EA, EB A, B (g)
C (dm /(s·bar))
3 b Cv Q[l/min(ANR)]* C (dm /(s·bar))
3 b Cv Q[l/min(ANR)]*
2 Single 35
0.61 0.44 0.16 171 0.64 0.45 0.18 181
position Double 37
Closed center 0.48 0.46 0.13 137 0.47 0.43 0.13 131
SYA320-M5 Exhaust M5
3 0.47 0.42 0.13 130 0.47 (0.44) 0.41 (0.37) 0.13 (0.12) 129 (117)
position center 39
Pressure
0.50 (0.41) 0.48 (0.35) 0.15 (0.11) 145 (108) 0.47 0.43 0.13 131
center
2 Single 44
0.72 0.29 0.18 182 0.64 0.34 0.17 167
position Double 46
Closed center C4 0.59 0.28 0.15 148 0.59 0.30 0.15 150
SYA320-C4 Exhaust M5 M5 One-touch
3 0.63 0.35 0.16 166 0.42 (0.41) 0.34 (0.37) 0.11 (0.11) 110 (109)
fitting for ø4
position center 48
Pressure
0.76 (0.46) 0.42 (0.34) 0.21 (0.12) 210 (120) 0.59 0.29 0.15 149
center
2 Single 40
0.76 0.30 0.19 193 0.65 0.39 0.17 176
position Double 42
Closed center C6 0.76 0.55 0.24 233 0.60 0.33 0.16 156
SYA320-C6 Exhaust One-touch
3 0.65 0.32 0.16 167 0.64(0.42) 0.31 (0.36) 0.17 (0.11) 164 (111)
fitting for ø6
position center 44
Pressure
0.77 (0.49) 0.34 (0.43) 0.21 (0.15) 201 (136) 0.61 0.34 0.16 159
center
Note) ( ): denotes normal position.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

Model/Series SYA340 (Base mounted)


Pilot Flow characteristics Note 1)
Valve model Type of port size Port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Weight Note 2)
actuation (Nominal size) (g)
C (dm / (s·bar) )
3 b Cv Q[l/min(ANR)]* C (dm /(s·bar) )
3 b Cv Q[l/min(ANR)]*
2 Single 69 (34)
position Double 1.0 0.30 0.24 254 1.1 0.30 0.26 280
71 (36)
Closed center 0.77 0.28 0.18 193 0.85 0.30 0.19 216
SYA340-01 Exhaust M5 18
3 0.73 0.31 0.18 187 1.1 (0.55) 0.26 (0.52) 0.24 (0.16) 273 (164)
position center 73 (38)
Pressure
1.2 (0.51) 0.24 (0.45) 0.29 (0.14) 294 (144) 0.89 0.47 0.24 255
center
Note 1) ( ): denotes normal position.
Note 2) [ ]: Without sub-plate.
* These values have been calculated according to ISO6358 and represent the flow rate measured
in standard conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential
pressure of 0.1MPa.

185
SYA3000/5000/7000

Flow Characteristics/Weight

Model/Series SYA540 (Body ported)


Pilot Flow characteristics Note)
Type of Port size Weight
Valve model port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
actuation (Nominal size) P, EA, EB A, B Q[l/min(ANR)]* C [dm3/(s·bar)] Q[l/min(ANR)]* (g)
C [dm3/(s·bar)] b Cv b Cv
2 Single 58
1.9 0.35 0.49 499 2.4 0.39 0.61 648
position Double 64
SYA520-01 Closed center Rc 1 8 1.7 0.43 0.45 473 1.8 0.35 0.46 473
3
1.5 0.44 0.41 420 2.5 [1.5] 0.32 [0.43] 0.59 [0.40] 644 [417] 69
position Exhaust center
Pressure center 2.2 [0.91] 0.46 [0.58] 0.61 [0.28] 626 [287] 1.8 0.38 0.46 483
2 Single 82
0.75 0.43 0.20 209 0.85 0.64 0.30 285
position Double C4 87
SYA520-C4
3
Closed center
position Exhaust center
( One-touch
fitting for ø4 ) 0.74
0.75
0.40
0.36
0.19
0.19
201
198
0.84 0.57 0.28
0.84 [0.84] 0.64 [0.53] 0.30 [0.27]
263
281 [253] 93
Pressure center M5 x 0.8 18 0.78 [0.71] 0.44 [0.37] 0.21 [0.18] 219 [189] 0.84 0.57 0.27 263
2 Single 76
1.5 0.33 0.33 389 2.0 0.37 0.52 533
position Double C6 82
SYA520-C6
3
Closed center
position Exhaust center
( One-touch
fitting for ø6) 1.3
1.3
0.31
0.33
0.33
0.33
333
337
1.6 0.32 0.39
1.8 [1.4] 0.35 [0.37] 0.44 [0.35]
412
473 [373] 87
Pressure center 1.7 [0.80] 0.31 [0.47] 0.42 [0.23] 435 [229] 1.7 0.33 0.44 441
2 Single 68
1.9 0.21 0.45 458 2.3 0.29 0.57 581
position Double C8 74
SYA520-C8
3
Closed center
position Exhaust center
( One-touch
fitting for ø8 ) 1.6
1.4
0.29
0.38
0.39
0.39
404
375
1.7 0.38 0.46
2.0 [1.5] 0.37 [0.40] 0.52 [0.43]
456
533 [411] 79
Pressure center 2.2 [1.6] 0.32 [0.44] 0.56 [0.44] 567 [448] 1.8 0.41 0.50 493
Note) [ ]: denotes normal position. * These values have been calculated according to ISO6358 and represent the flow rate measured in standard
conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.

Model/Series SYA540 (Base mounted)


Pilot Flow characteristics Note 1)
port size Weight Note 2)
Valve model Type of actuation Port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(Nominal size) C [dm /(s·bar)]
3 b Cv Q[l/min(ANR)]* C [dm /(s·bar)]
3 b Cv Q[l/min(ANR)]* (g)
2 Single 707 105 (42)
2.4 0.41 0.64 658 2.8 0.29 0.66
position Double 110 (47)
SYA540-02 Closed center M5 x 0.8 14 1.8 0.47 0.50 516 1.8 0.40 0.47 490
3 1.4 778 [347]
Exhaust center 0.55 0.44 430 3.0 [1.2] 0.33 [0.48] 0.72 [0.37] 115 (52)
position 490
Pressure center 3.3 [0.84] 0.36 [0.60] 0.85 [0.28] 873 [270] 1.8 0.40 0.48
Note 1) [ ]: denotes the normal position. * These values have been calculated according to ISO6358 and represent the flow rate measured in standard
Note 2) ( ): denotes without sub-plate. conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.

Model/Series SYA720 (Body ported)


Pilot Flow characteristics Weight
Port size
Valve model Type of actuation port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(Nominal size) P, EA, EB (g)
A, B C [dm3/(s·bar) ] b Cv Q[l/min(ANR)]* C [dm3/(s·bar) ] b Cv Q[l/min(ANR)]*
2 Single 999 855 132
4.1 0.23 0.93 3.3 0.33 0.81
position Double 177
SYA720-02 Closed center 14 2.9 0.31 0.70 742 2.4 0.38 0.63 644
3 2.5 675 893 [563] 186
Exhaust center 0.39 0.65 3.4 [2.1] 0.35 [0.38] 0.82 [0.54]
position 1048 [618] 594
Pressure center 4.3 [2.4] 0.23 [0.32] 0.97 [0.61] 2.2 0.39 0.58
2 Single P port: 138
14 3.2 0.26 0.77 794 3.2 0.37 0.82 852
position Double C8 183
SYA720-C8
3
position
Closed center
Exhaust center
18

EA, EB port
( One-touch
fitting for ø8) 2.6
2.4
0.24
0.25
0.63
0.57
637
592
2.4 0.31 0.62
2.6 [1.9] 0.42 [0.46] 0.70 [0.56]
614
718 [541] 192
Pressure center 3.3 [2.4] 0.28 [0.22] 0.78 [0.57] 829 [581] 2.2 0.34 0.60 574
2 Single :18 135
3.8 0.26 0.86 943 3.2 0.34 0.82 835
position Double C10 180
SYA720-C10
3
position
Closed center
Exhaust center ( One-touch
fitting for ø10 ) 2.8
2.5
0.27
0.25
0.67
0.59
699
616
2.4 0.21 0.59
2.7 [2.0] 0.38 [0.38] 0.70 [0.56]
578
724 [536] 189
Pressure center 3.8 [2.4] 0.25 [0.31] 0.89 [0.61] 937 [614] 2.3 0.38 0.61 617
Note) [ ]: denotes normal position. * These values have been calculated according to ISO6358 and represent the flow rate measured in standard
conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.

Model/Series SYA740 (Base mounted)


Pilot Flow characteristics Note 1)
Valve model Type of actuation port size Port size 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Weight Note 2)
(Nominal size) C [dm3/(s·bar)] b Cv Q[l/min(ANR)]* C [dm3/(s·bar)] b Cv Q[l/min(ANR)]* (g)
2 Single 240 (111)
4.1 0.41 1.1 1123 4.1 0.29 1.0 1036
position Double 286 (157)
SYA740-02 Closed center 18 14 3.0 0.43 0.80 834 2.6 0.41 0.72 712
3 2.6 718
Exhaust center 0.42 0.71 4.7 [1.7] 0.35 [0.48] 1.1 [0.49] 1235 [492] 294 (165)
position 1431 [670]
Pressure center 5.3 [2.3] 0.39 [0.49] 1.3 [0.65] 2.2 0.49 0.63 641
2 Single 240 (111)
4.9 0.29 1.2 1238 4.5 0.27 1.1 1123
position Double 286 (157)
SYA740-03 Closed center 18 38 3.0 0.40 0.80 816 2.6 0.45 0.73 734
3 2.6 718
Exhaust center 0.42 0.71 4.8 [1.7] 0.35 [0.48] 1.1 [0.49] 1261 [492] 294 (165)
position 1356 [682]
Pressure center 5.3 [2.3] 0.31 [0.51] 1.3 [0.64] 2.3 0.45 0.66 649
Note 1) [ ]: denotes the normal position. * These values have been calculated according to ISO6358 and represent the flow rate measured in standard
Note 2) ( ): denotes without sub-plate. conditions at an upstream pressure of 0.6 MPa (relative pressure) and a differential pressure of 0.1MPa.
186
SYA3000/5000/7000

Series SYA3000: Body Ported

2 position single Foot bracket


SYA3120- C4, N3 (-F2)
C6, N7
SYA3120-C4, N3
C6, N7 -F1

ø1.3
(Ventilation hole)

M5
(P, EA, EB port)
2 – ø1.5 die-cast hole
(For manifold gasket positioning)

(2 –ø3.2 for mounting)

Manual override
(Non-locking)

Manual override
(Non-locking)

One-touch fitting
(A, B port)
M5 Applicable tubing O.D.: ø4, ø1/4" 2 – ø3.2
(Pilot port) ø6, ø5/32" (For mounting)

2 – ø2.2
(For manifold mounting)

SYA3120-M5

M5
(A, B port)

187
SYA3000/5000/7000

Series SYA3000: Body Ported


2 position double
SYA3220- C4, N3
C6, N7 (-F2)
ø1.3
(Ventilation hole)

2 – ø1.5 die-cast hole


(For manifold gasket positioning) M5
(P, EA, EB port)

Manual override
(Non-locking)

SYA3220-M5
One-touch fitting
M5 (A, B port)
(A, B port) M5 Applicable tubing O.D.: ø4, ø1/4"
(Pilot port) ø6, ø5/32"

2 – ø2.2
(For manifold mounting)

3 position closed center / exhaust center / pressure center


3
SYA34 20-C4, N3
C6, N7 (-F2)
5
ø1.3
(Ventilation hole)

2 – ø1.5 die-cast hole


(For manifold gasket positioning) M5
(P, EA, EB port)

Manual override
(Non-locking)

3
SYA34 20-M5
5

One-touch fitting M5
(A, B port) (A, B port)
M5 Applicable tubing O.D.: ø4, ø1/4"
(Pilot port) ø6, ø5/32"

2 – ø2.2
(For manifold mounting)

188
SYA3000/5000/7000

Series SYA3000: Base Mounted

2 position single
SYA3140-01

Ventilation hole 1/8


(Piping port)

2 – ø3.2
(For mounting) Manual override
(Non-locking)

M5
(Pilot port)

2 position double
SYA3240-01

Ventilation hole
1/8
(Piping port)
2 – ø3.2
(For mounting) Manual override
(Non-locking)

M5
(Pilot port)

189
SYA3000/5000/7000

Series SYA3000: Base Mounted

3 position closed center / exhaust center / pressure center


3
SYA3 4 40-01
5

1/8
Ventilation hole
(Piping port)

2 – ø3.2 Manual override


(For mounting) (Non-locking)

M5 x 0.8
(Pilot port)

190
SYA3000/5000/7000

Series SYA5000: Body Ported

2 position single Foot bracket


C4, N3 C4, N3
SYA5120- C6, N7 (-F2) SYA5120-C6, N7 -F1
C8, N9 C8, N9
ø1.8
(Ventilation hole)

2 – ø1.5 die-cast hole


(For manifold gasket positioning) 1/8
(P, EA, EB port)

2 – ø3.2
(For mounting)

Manual override
(Non-locking)

Normal override 2 – ø3.2


M5 (Non-locking) (For mounting)
(Pilot port)

One-touch fitting 2 – ø3.2


(A, B port) (For manifold mounting)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø5/16"
ø8, ø1/4"
SYA5120-01

1/8
(A, B port)

191
SYA3000/5000/7000

Series SYA5000: Body Ported


2 position double SYA5220-01
C4, N3 1/8
SYA5220-C6, N7 (-F2) (A, B port)
C8, N9
1/8
ø1.8 (P, EA, EB port)
(Ventilation hole)

2 – ø2.2 die-cast hole


(For manifold gasket positioning)

Manual override
(Non-locking)
M5
(Pilot port)

One-touch fitting
(A, B port) 2 – ø3.2
Applicable tubing O.D.: ø4, ø5/32" (For manifold mounting)
ø6, ø1/4"
ø8, ø5/16"
3
3 position closed center / exhaust center / pressure center SYA54 20-01 1/8
3 C4, N3 5 (A, B port)
SYA54 20-C6, N7 (-F2)
5 C8, N9
ø1.8
(Ventilation hole)

1/8
2 – ø2.2 die-cast hole (P, EA, EB port)
(For manifold gasket positioning) 2 – ø3.2
(For mounting)

Manual override
(Non-locking)

2-M5
(Pilot port)

2 – ø3.2
One-touch fitting (For manifold mounting)
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16" 192
SYA3000/5000/7000

Series SYA5000: Base Mounted

2 position single
SYA5140-02

Ventilation hole

1/4
(Piping port)
2 – ø4.3
(For mounting)

M5
(Pilot port)
Manual override
(Non-locking)

2 position double
SYA5240-02

Ventilation hole

1/4
(Piping port)

2 – ø4.3
(For mounting)

M5 x 0.5
(Pilot port)

Manual override
(Non-locking)

193
SYA3000/5000/7000

Series SYA5000: Base Mounted

3 position closed center / exhaust center / pressure center


3
SYA54 40-02
5

Ventilation hole

1/4
(Piping port)

2 – ø4.3
(For mounting)

M5
(Pilot port)
Manual override
(Non-locking)

194
SYA3000/5000/7000

Series SYA7000: Body Ported

2 position single Foot bracket


SYA7120- C8, N9
C10, N11(-F2) SYA7120- C8, N9
C10, N11 -F1
1/4
ø1.8
(P port)
(Ventilation hole)

2 – ø2.2 die-cast hole


1/8
(For manifold gasket positioning)
(EA, EB port)

2 – ø4.2
(For mounting)

Manual override
(Non-locking)
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"
1/8
(Pilot port)
Manual override
(Non-locking)
2 – ø4.2
(For manifold mounting)

SYA7120-02

1/4
(A, B port)

195
SYA3000/5000/7000

Series SYA7000: Body Ported


2 position double
C8, N9
SYA7220- 
C10, N11 1/4
(P port)
ø1.8
(Ventilation hole)

2 – ø2.2 die-cast hole


(For manifold gasket positioning) 1/8
(EA, EB port)

Manual override
SYA7220-02
(Non-locking)
1/4
1/8 (A, B port)
(Pilot port)

One-touch fitting 2 – ø4.2


(A, B port) (For manifold mounting)
Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"

3 position closed center / exhaust center / pressure center


3 C8, N9
SYA7 20- 4  N11
C10, 1/4
5
ø1.8 (P port)
(Ventilation hole)

2 – ø2.2 die-cast hole


(For manifold gasket positioning)
1/8
(EA, EB port)

3
Manual override SYA74 20-02
(Non-locking) 5
1/4
(A, B port)

1/8
(Pilot port)

One-touch fitting 2 – ø4.2


(A, B port) (For manifold mounting)
Applicable tubing O.D.:ø8, ø5/16"
ø10, ø3/8"
196
SYA3000/5000/7000

Series SYA7000: Base Mounted

2 position single
SYA7140-02
03 

Ventilation hole

3/8, 1/4
(Piping port)
2 – ø4.3
(For mounting)
1/8
(Pilot port)

Manual override
(Non-locking)

2 position double
SYA7240- 02
03 

Ventilation hole

3/8, 1/4
(Piping port)

2 – ø4.3
(For mounting)
1/8
(Pilot port)

Manual override
(Non-locking)

197
SYA3000/5000/7000

Series SYA7000: Base Mounted

3 position closed center / exhaust center / pressure center


3
SYA74 40-02
03 
5

Ventilation hole

3/8, 1/4
(Piping port)

2 – ø4.3
(For mounting)
1/8
(Pilot port)

Manual override
(Non-locking)

198
199
200
201
202
5 Port Solenoid Valve
Series SY3000/5000
Made to Order
Type 45 External Pilot/Built-in Silencer
External pilot manifold bases for low-pressure/vacuum use are added to split style/DIN rail manifolds.
The built-in silencer has materialised a clear-cut appearance.

Individual Wiring/Connector Box Type


How to Order Manifold How to Order Valve Manifold Assembly (Example)

Type 45
Example
SS5Y35 45( A) 05 U R C6 -Q Single solenoid (external pilot specifications)
Series SY3140R-5G-Q (5set)
3 SY3000
5 SY5000
Built-in silencer
Valve stations Option
When a longer
Symbol Stations
SUP/EXH block assembly mounting position DIN rail is Manifold base (5 stations)
02 2 stations
Symbol Mounting position Stations desired than the –
+
SS5Y3-45-05DRS-C6-Q
...

...

specified

U U side
+

20 20 stations

+

D D side 2 to 10 stations stations, specify –


+

The number of the station



+

blanking plate B Both sides 2 to 20 stations


number to be
assembly is M Special specifications required. (Max.
U

included.
si

∗ For special specifications, indicate Sta


de

20 stations)
separately by the manifold specification tion
s
SUP/EXH block assembly specifications
2
1

Symbol Specifications
D
si
de

R External pilot specifications


S Internal pilot/Built-in silencer
RS External pilot/Built-in silencer
SS5Y3-45-05DRS-C6-Q 1 set (External pilot specification with
built-in silencer part no.)
A, B port size ∗ SY3140R-5G-Q 5 sets (Single solenoid part no.)
One-touch fitting (Metric size) One-touch fitting (Inch size)
The asterisk denotes the symbol for assembly.
Symbol Port size Applicable series Symbol Port size Applicable series
Prefix it to the part nos. of the solenoid valve, etc.
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
The valve arrangement is numbered as the 1st. station from D side regardless of
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1 4" SY3000 the mounting position of SUP/EXH block assembly. In ordering, specify the part
M Mixed M Mixed nos. in the order from the 1st. station on D side. Besides, when the arrangement will
be complicated, fill out the manifold specification sheet to instruct us.
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" For manifolds with SUP/EXH block assembly at each end of the manifold, external
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4" pilot ports and silencers will be also located at each end of the manifold.
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16" The SUP/EXH block assembly (SX3/5000_51_1A), for special usage, as shown on
page 125, can also be mounted. Please specify the mounting position, by correctly
M Mixed M Mixed filling in the blank space on the manifold specification sheet.
∗ In the case of mixed specifications, indicate separately on the manifold
specification sheet.

203
SY3000/5000 Made to Order Type 45
How to Order Valve

SY 5 2 40 5 L -Q
Series Manual override
3 SY3000 - Non-locking push type
5 SY5000 D Push-turn locking slotted type
E Push-turn locking lever type
Type of actuation
Light/surge voltage suppressor
1 2 position single
2 2 position double Electrical entry for G, H, L, M, W
3 3 position closed center - Without light/surge voltage suppressor
4 3 position exhaust center S With surge voltage suppressor
5 3 position pressure center Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
Pilot type
∗ Power saving circuit is only available in the "Z" type.
- Internal pilot
R External pilot
Electrical entry for D (SY5000 only)
Coil specifications - Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
- Standard
With power saving circuit (24 VDC, 12 VDC only) Z With light/surge voltage suppressor (Non-polar type)
T
∗ DOZ is not available.
∗ Power saving circuit is not available
∗ For AC voltage valves there is no “S” option. It is
in the case of D, DO or W type. already built-in to the rectifier circuit.

Rated voltage
For DC
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
For AC (50 60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of Type
D and DO is only available
with 12 and 24 VDC.
∗ AC specification is only
available with D and DO type.
∗ D and DO only available
for SY5000.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC 100, 110, 24, 12, 6, 5, 3 VDC
200, 220 VAC
Grommet L plug connector M plug connector DIN terminal M8 connector ∗
G: Lead wire length L: With lead wire M: With lead wire (SY5000 only) WO: Without connector
300 mm (Length 300 mm) (Length 300 mm) D: With connector cable
H: Lead wire length LN: Without lead wire MN: Without lead wire DO: Without connector W: With connector
600 mm LO: Without connector MO: Without connector cable Note 1)
∗ LN, MN type: with 2 sockets.
∗ D and DO only available for SY5000.
∗ DIN terminal type “Y” which conforms to EN-175301-803C (former DIN43650C) is also available.
For details, refer to page 210.
∗ Setting “-5LOU” is available only for connector box type.
∗ For connector cable of M8 connector, refer to back page 12.
∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available. For details, see page 211.
Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring to back page 13.

204
Type 45 Made to Order

Plug-in
How to Order Manifold How to Order Valve Manifold Assembly (Example)
Type 45
Example
3
SS5Y 45
5 F U 05 U R -Q Single solenoid (external pilot specifications)
SY3140R-5FU-Q (3 sets)
Double solenoid (external pilot specifications)
Series SY3245R-5FU-Q (1 set)
3 SY3000
5 SY5000 Built-in silencer
Common specifications Connector mounting position
- Positive common Symbol Mounting position
Manifold base (5 stations)
N Negative common U U side
SS5Y3-45FU-05DRS-C6-Q
No symbol is used for T, T1, S types. D D side
Connector type
Symbol Mounting position

U
F D-sub connector

sid
e
Sta
P Flat ribbon cable 26 pins

tio
ns
PG Flat ribbon cable 20 pins

2
PH Flat ribbon cable 10 pins

1
D
sid
T Terminal block 9 pins

e
T1 Terminal block 18 pins SS5Y3-45FU-05DRS-C6-Q 1 set (External pilot specification with
built-in silencer part no.)
S Serial Transmission Type
∗ SY3140R-5FU-Q 3 sets (Single solenoid part no.)
∗ For details, refer to page 135. ∗ SY3245R-5FU-Q 1 set (Double solenoid part no.)
The asterisk denotes the symbol for assembly.
Valve stations Prefix it to the part nos. of the solenoid valve, etc.
Symbol Stations Note The valve arrangement is numbered as the 1st. station from D side regardless of
02 2 stations the mounting position of SUP/EXH block assembly. In ordering, specify the part
nos. in the order from the 1st. station on D side. Besides, when the arrangement will
Single wining spec.
...

...

be complicated, fill out the manifold specification sheet to instruct us.


20 20 stations For manifolds with SUP/EXH block at each end of the manifold, external pilot ports
and silencers will be also located at each end of the manifold.
∗ This also includes the number of blanking plate assemblies. The SUP/EXH block assembly (SX3/5000_51_1A), for special usage, as shown on
∗ Depending on the connector, the number of stations is page 264, can also be mounted. Please specify the mounting position, by correctly
limited. Refer to page 138. filling in the blank space on the manifold specification sheet.
∗ Two stations are necessary for the double, 3 position Two stations of the manifold base are necessary for the double, 3 position (Dual
body type). Use caution when specifying the number of stations required for the
solenoid valve (Dual body type).
manifold base.
SUP/EXH block assembly mounting position
Symbol Mounting position Stations How to Order Valve
U U side
2 to 10 stations
D D side
B
M
(Both sides) 2 to 20 stations
Special specifications
SY 3 1 4 5 FU -Q
∗ For special specifications, indicate
separately by the manifold specification
Series
3 SY3000
SUP/EXH block assembly specifications
5 SY5000
Symbol Specifications
R External pilot specifications Type of actuation
S Internal pilot/Built-in silencer 1 2 position single
RS External pilot/Built-in silencer 2 2 position double
A, B port size 3 3 position closed center
One-touch fitting (Metric size) One-touch fitting (Inch size) 4 3 position exhaust center
Symbol Port size Applicable series Symbol Port size Applicable series 5 3 position pressure center
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" Body Option
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1 4" SY3000 0 Standard (Single only)
M Mixed M Mixed 5 Dual body type (Double, 3 position)
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4" Pilot type
SY5000 SY5000 - Internal pilot
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
M Mixed M Mixed R External pilot
∗ In the case of mixed specifications, indicate separately on the manifold Rated voltage
specification sheet.
Voltage 5 24 VDC
- 24 VDC 6 12 VDC Manual override
Option
12V 12 VDC When a longer DIN rail is desired than V∗ 6 VDC - Non-locking push type
the specified stations, specify the S∗ 5 VDC D Push-turn locking slotted type
No symbol is used for T, T1, S
station number to be required. R∗ 3 VDC E Push-turn locking lever type
types.
(20 stations at maximum)
∗ Mark: 45T and T1 only
S type is available
for 24 VDC only.
205
SY3000/5000 Made to Order Type 45
External Pilot/Built-in Silencer

SY3000: SS5Y3-45- Stations DRS-C4, N3


C6, N7 -Q

(Station n) (Station 1)
(Lead wire length)
Approx. 300

Manual override

(C6: 3.2)
(N7: 7)
Silencer
(Air discharge port)

(3)
B B

8
37.2
28.7

34
15.7
97.3

B B B B B A

88.8
5.5
35

A A A A A
39.9

DIN rail (L4)33


L3
DIN rail holding screw L2 5
(Rail mounting hole pitch: 12.5) ∗ The dimensions L1 to L4 are identical to those of
L1 SS5Y3-45- Stations
U C4, N3
D -C6, N7 -Q.
B
U side D side
One-touch fitting
(P port)
One-touch fitting
Applicable tubing O.D.: ø8, ø5/16"
SS5Y3-45- Stations DR-C4, N3
C6, N7 -Q
(A, B port) (Pitch)

10.2
Applicable tubing O.D.: ø4, ø5/32" P = 10.5 13.5 24.8 Button for DIN rail release 1.2
ø6, ø1/4"
11.2
22.2

25.2

A A A A A A A

38.6
48.4

R
50
63.7
63.3

B B B B B B
P P

One-touch fitting
PE

- + - +

(P, R port)
X X

(Light/surge voltage suppressor) 1.2 One-touch fitting Applicable tubing O.D.: ø8, ø5/16"
One-touch fitting
(X port) (PE, X port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32"

C4, N3
SY5000: SS5Y5-45- Stations DRS-C6, N7 -Q
C8, N9
(Lead wire length)

Silencer (Air discharge port)


Approx. 300

Manual
override B

DIN rail holding screw


(4.9)

(3.5)

DIN rail
A
44.2

8
41.2
31.6
119.9

B B B B B
107.2
35
5.5

31.2
48.3
53.4

A A A A A

∗ The dimensions L1 to L4 are identical to those of


U C4, N3
SS5Y3-45- Stations D - C6, N7-Q.
B C8, N9

L3 (L4) 3
∗ The dimensions of SS5Y 5 -45- Stations URS-Q are identical to
L2 5 those of SS5Y 35-45F- Stations DRS-Q.
(Rail mounting hole pitch: 12.5)
L1
C4, N3
One-touch fitting
U side D side SS5Y5-45- Stations DR- C6, N7 -Q
C8, N9
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
ø6, ø1/4" P = 16 17 26 Button for DIN rail release 6.8
ø8, ø5/16"
15.5
31.5

32

46.5
14.5
54.5
55.7

A A A A A A R
71.1

72.4

B B B B B P B P

One-touch fitting
PE
-+ -+
X X

(P, R port)
(Light/surge voltage suppressor) 3.4 One-touch fitting
Applicable tubing O.D.: ø10, ø3/8"
(Station n) (Station 1) (P port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting One-touch fitting
(X port) (PE, X port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32"

206
Type 45 Made to Order
External Pilot/Built-in Silencer

SY3000: SS5Y3-45FU- Stations DRS- C4,N3


C6,N7 -Q
U side Silencer D side
(Air discharge port)
L3 L4
Equivalent to the applicable DIN rail holding screw

(C6: 3.2)
26.5

(N7: 7)
D-sub connector {JIS-X-5101, MIL-C-24308} M2.6 DIN rail

(3)
8

34
PORT

PORT
B B B B B
SOL.a

SOL.a
SOL.b

SOL.b
5.5
35

15.7
87.7
92

A A A
3.9

24VDC
+COM
Manual override

( Press and turn to operate


)
- +

and lock override.


Terminal no. 1 A side: Blue
Power supply terminals L2 5 B side: Yellow
(Rail mounting hole pitch: 12.5)
(
The voltage indication
marking is for 24 VDC. ) L1
One-touch fitting SS5Y3-45FU- Stations DR- C4,N3
C6,N7 -Q
(A, B port) (Pitch) Button for DIN rail release
Applicable tubing O.D.: ø4, ø5/32" P = 10.5 13.5 24.8 1.2

10.2
ø6, ø1/4"
22.2
11.2

25.2

A A A A A A A

38.6
R
50
63.3

63.7

B B B B B B
P P

One-touch fitting
PE

(P, R port)
X X

1.2 One-touch fitting Applicable tubing O.D.: ø8, ø5/16"


(Station n) (Station 1) (P port)
Applicable tubing O.D.: ø8, ø5/16" One-touch fitting
(PE, X port)
∗ The dimensions L1 to L4 are identical to those of One-touch fitting Applicable tubing O.D.: ø4, ø5/32"
SS5Y3-45F U
U C4, N3
(X port)
D- Stations D - C6, N7.
B Applicable tubing O.D.: ø4, ø5/32"

C4,N3
SY5000: SS5Y5-45FU- Stations DRS- C6,N7 -Q
C8,N9
U side Equivalent to the applicable D side
D-sub connector {JIS-X-5101, MIL-C-24308}
L3 L4
(4.9)
(3.5)

27 M2.6
DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

32.5

A A A A

Silencer
24VDC
+COM (Air discharge port)
- +

Manual override
Terminal no. 1
Power supply terminals
L2 5 ( Press and turn to operate
and lock override. ) ∗ The dimensions L1 to L4 are identical to those of
(Rail mounting hole pitch: 12.5) A side: Blue
( )
U C4, N3
The voltage indication U
SS5Y3-45FD - Stations D - C6, N7 -Q
L1 B side: Yellow
marking is for 24 VDC. B C8, N9

∗ The dimensions of SS5Y35 -45- Stations URS-Q are identical to


3
those of SS5Y 5-45- Stations DRS-Q.
One-touch fitting C4,N3
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
SS5Y5-45FU- Stations DR- C6,N7 -Q
Button for DIN rail release C8,N9
ø6, ø1/4" P = 16 17 26 6.8
ø8, ø5/16"
15.5
31.5

32

46.5
14.5
54.5

A A A A A A R
72.4
72.9

B B B B B P B P

PE

X X One-touch fitting
(P, R port)
3.4 One-touch fitting Applicable tubing O.D.: ø10, ø3/8"
(P port) Applicable tubing O.D.: ø10, ø3/8" One-touch fitting
(Station n) (Station 1) One-touch fitting (PE, X port)
(X port) Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32"

207
5 Port Solenoid Valve
Series SY3000/5000
Made to Order
Type M45 Mixed Mounting Type
Non plug-in
Use SY3000 together with SY5000, which has a large Cv and is mounted only in a place where it is needed, permits a selection of economic manifold bases.
How to Order Manifold How to Order Valve Manifold Assembly (Example)
Type M45 (Mixed mounting style)
Example
SS5Y5 M45 05 U C86 -Q Manifold base (5 stations)
SS5Y5-M45-05U-C86-Q
Single solenoid valve
Mixed mounting style SY3140-5G-Q (3 sets)
Valve stations Single solenoid valve
SUP/EXH block assembly mounting position SY3140-5G-Q (2 sets)
Symbol Stations Option
02 2 stations Symbol Mounting position Stations When a longer
U U side
...

...

2 to 10 stations DIN rail is desired


20 20 stations D D side than the specified
The number B Both sides 2 to 20 stations stations, specify
of blanking M Special specifications the station
plate ass’y is ∗ For special specifications, indicate separately number to be
included, too. by the manifold specification heet. required.
(Max. 20 stations) U
SUP/EXH block assembly specifications sid
e
Sta
tio
Symbol Specifications
- Standard/Internal pilot specifications ns
S Built-in silencer Manifold block
assembly for

2
∗ External pilot specification is unavailable for

1
SY5000

D
sid
mixed mounting style.

e
A, B port size SX5000-50-1A--Q Manifold block assembly for SY3000
One-touch fitting (Metric size) One-touch fitting (Inch size) SX5000-50-8A--Q
Symbol Port size Symbol Port size
One-touch fitting for ø5 32" SS5Y5-M45-05U-C86-Q 1 set (Type M45, manifold base part no.)
C44 SY5000: One-touch fitting for ø4
SY3000: One-touch fitting for ø4
N33 SY5000:
SY3000: One-touch fitting for ø5 32" ∗ SY3140-5G-Q 3 sets (Single solenoid part no.)
C46 SY5000: One-touch fitting for ø4 N37 SY5000: One-touch fitting for ø5 32" ∗ SY5140-5G-Q 2 sets (Single solenoid part no.)
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4"
The asterisk denotes the symbol for assembly.
C64 SY5000: One-touch fitting for ø6 N73 SY5000: One-touch fitting for ø1 4"
SY3000: One-touch fitting for ø4 SY3000: One-touch fitting for ø5 32" Prefix it to the part nos. of the solenoid valve, etc.

C66 SY5000: One-touch fitting for ø6 N77 SY5000: One-touch fitting for ø1 4" The valve arrangement is numbered as the 1st. station from D side regardless of
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4" the mounting position of SUP/EXH block assembly. In ordering, specify the part
C84 SY5000: One-touch fitting for ø8 N93 SY5000: One-touch fitting for ø5 16" nos. in the order from the 1st. station on D side. Besides, when the arrangement
SY3000: One-touch fitting for ø4 SY3000: One-touch fitting for ø5 32" will be complicated, fill out the manifold specification sheet to instruct us.
C86 SY5000: One-touch fitting for ø8 N97 SY5000: One-touch fitting for ø5 16"
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4"
M Mixed M Mixed
∗ In the case of mixed specifications, indicate separately on the manifold
specification sheet.

How to Order Valve

SY 5 2 40 5 L -Q
Manual override
Electrical entry for G, H, L, M, W - Non-locking push type
Series - Without light/surge voltage suppressor D Push-turn locking slotted type
3 SY3000 S With surge voltage suppressor E Push-turn locking lever type
5 SY5000 Z With light/surge voltage suppressor
Coil specifications R With surge voltage suppressor (Non-polar type)
Type of actuation - Standard U With light/surge voltage suppressor (Non-polar type)
1 2 position single With power saving circuit
T ∗ Power saving circuit is only available in the "Z" type.
2 2 position double (24 VDC, 12 VDC only)
3 3 position closed center ∗ Power saving circuit
4 3 position exhaust center is not available in Electrical entry
5 3 position pressure center the case of W
type. 24, 12, 6, 5, 3 VDC
Grommet L plug connector M plug connector M8 connector ∗
Rated voltage G: Lead wire L: With lead wire M: With lead wire WO: Without
For DC length 300 mm (Length 300 mm) (Length 300 mm) connector cable
5 24 VDC H: Lead wire LN: Without lead wire MN: Without lead wire W: With connector
6 12 VDC length 600 mm LO: Without connector MO: Without connector cable Note 1)
V 6 VDC ∗ LN, MN type: with 2 sockets.
S 5 VDC ∗ For connector cable of M8 connector, refer to back page 12.
R 3 VDC ∗ Connector M8 type “WA” conforming to IEC 60947-5-2 standard, is also available.
For details, see page 211.
∗ For type W, DC voltage Note 1) Enter the cable length symbols in . Please be sure to fill in the blank referring
is only available. to back page 13.
208
M45 Made to Order
Type

Dimensions: Mixed Mounting

SS5Y5-M45- Stations U--Q

(Lead wire length)


L3

Approx. 300

(Lead wire length)


17 18 16 x n2 12.5 x n1 17

Approx. 300
16 12.5
(SY5000) (SY3000)

(C6: 3.2)
(N7: 7)
(3.5)
-6
DIN rail
8

44.2
41.2
31.6

28.9
B B B

24 20.4
120

35
107.4

97.5
B B B

89
5.5
31.2
A A A

46.3
48.3
A A A

53.5 DIN rail holding screw


Manual override
(L4)
L dimension: Formulae for L1, L4 L2 5
L3 = 12.5 x n1 + 16 x n2 + 52 (Rail mounting hole pitch: 12.5)
L3 L1
M= ( + 1) Omit decimals
12.5 SY5000 SY3000
L1 = 12.5 x M + 23 Pitch Pitch

16.9
26 17 P=16 P=12.5 23.3

15.5
L2 = L1–10.5 Button for DIN rail release
L4= (L1–L3) /2
14.5

31.5
n1 = Number of SY3000
32

n2 = Number of SY5000
R A A A A A A
71.1

71.5
P B B B B B B
One-touch fitting
One-touch fitting
+

A, B port
Note) The L1 to L4 dimensions of P, R port -+ -+ -+ -+
Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8" ø6, ø1/4"
SS5Y5-M45- Stations D-Q are
identical to those of SS5Y5-M45- One-touch fitting (Light/surge voltage suppressor)
Stations U-Q. A, B port
Applicable tubing O.D.: ø4, ø5/32" (Station n) (Station 1)
ø6, ø1/4"
ø8, ø5/16"
SS5Y5-M45- Stations B--Q
(Lead wire length)

L3
Approx. 300

(Lead wire length)


Approx. 300
17 18 16 x n2 12.5 x n1 18 17
16 12.5
(SY5000) (SY3000)
(C6: 3.2)
(N7: 7)
(3.5)
-6

DIN rail
8
44.2
41.2
31.2 31.6

28.9

B B B
24 20.4
120
107.4

97.5

B B B
89
35
5.5

A A A
46.3
48.3

A A A
53.5

Manual
DIN rail holding screw
override (L4)
L2 5
(Rail mounting hole pitch: 12.5)
L1

L dimension: Formulae for L1, L4 SY5000 SY3000


L3 = 12.5 x n1 + 16 x n2 + 70 Pitch Pitch
26 17 P=16 P=12.5 15.3 26
15.5

16.9

L3 Button for DIN rail release


M= ( + 1) Omit decimals
12.5
31.5

L1 = 12.5 x M + 23
32

14.5

L2 = L1 – 10.5
R A A A A A A R
71.1

71.5

L4 = (L1 – L3)/2 P B B B B B B P

One-touch fitting One-touch fitting


n1 = Number of SY3000 P, R port -+ -+ A, B port
Applicable tubing O.D.: ø4, ø5/32"
-+ -+

n2 = Number of SY5000 Applicable tubing O.D.: ø10, ø3/8"


One-touch fitting
ø6, ø1/4"
(Light/surge voltage suppressor)
A, B port
Applicable tubing O.D.: ø4, ø5/32" (Station n) (Station 1)
ø6, ø1/4"
ø8, ø5/16"
209
5/3 Port Solenoid Valve
Series SY5000/7000/9000, SY500
Made to Order
DIN Connector Conforming to EN-175301-803C (former DIN 43650C)
DIN connector type that conforms to the 8-mm pitch standards between DIN terminals.

How to Order Valve


A port size
Symbol Port size
Type of actuation - Base mounted
1 Normally open 01 18

2 Normally closed C4 One-touch fitting for ø4


C6 One-touch fitting for ø6
Type of actuation C8 One-touch fitting for ø8 Thread type
Series
N3 One-touch fitting for ø5 32" - Rc
5 SY500 3 Body ported N7 One-touch fitting for ø1 4"
5 Base mounted F G
N9 One-touch fitting for ø 5 16"
N NPT
3 port valve T NPTF
(5 port valve mixed SY 5 1 3 5 Y -Q
mounting style)
5 port valve SY 5 2 2 0 5 Y -Q
A, B port size
For body ported
Pilot type Electrical entry
Thread piping
Series - Internal pilot Symbol Port size Applicable series
Y: With connector 01 18 SY5000
5 SY5000 R∗ External pilot
7 SY7000 02 18 SY7000
∗ Base mounted 03 38 SY9000
9 SY9000 type only.
One-touch fitting (Metric size)
Type of actuation Rated voltage Symbol Port size Applicable series
C4 One-touch fitting for ø4
1 2 position single For DC C6 One-touch fitting for ø6 SY5000
2 2 position double 5 24 VDC C8 One-touch fitting for ø8
3 3 position closed center 6 12 VDC C8 One-touch fitting for ø8
YO: Without connector SY7000
4 3 position exhaust center C10 One-touch fitting for ø10
For AC (50 60 Hz)
C8 One-touch fitting for ø8
5 3 position pressure center 1 100 VAC C10 One-touch fitting for ø10 SY9000
2 200 VAC C12 One-touch fitting for ø10
Body type
3 110 VAC [115 VAC] One-touch fitting (Inch size)
2 Body ported
4 220 VAC [230 VAC] Symbol Port size Applicable series
4 Base mounted N3 One-touch fitting for ø5 32"
6 Body ported, cassette type N7 One-touch fitting for ø1 4" SY5000
Note) SY9000 series is not available
Light/surge voltage suppressor N9 One-touch fitting for ø5 16"
with body ported cassette type. - Without light/surge voltage suppressor N9 One-touch fitting for ø5 16"
SY7000
S With surge voltage suppressor N11 One-touch fitting for ø3 8"
Z With indicator light and surge voltage suppressor N9 One-touch fitting for ø5 16"
Note) When placing an order for body ported SY9000
∗ YOZ is not available. N11 One-touch fitting for ø3 8"
solenoid valve as a single unit,
∗ For AC voltage valves there is no “S” For Base Mounted
mounting bolt for manifold and gasket
option. It is already built-in to the rectifier Symbol Port size Applicable series
are not attached. Order them circuit. - Without sub-plate
separately, if necessary. (For details, 14 SY5000
refer to page 56.) Manual override 02 With sub-plate SY7000
- Non-locking push type 03
38 SY7000
D Push-turn locking slotted type With sub-plate SY9000
12
E Push-turn locking lever type 04 With sub-plate SY9000
How to Order Pilot Valve Assembly
DIN Connector Part No.
V115 5 Y Without light SY100-82-1
With light
Rated voltage Rated voltage Voltage symbol No.
For DC 24 VDC 24VN SY100-82-3-05
5 24 VDC 12 VDC 12VN SY100-82-3-06
Light/surge voltage suppressor
6 12 VDC 100 VAC 100VN SY100-82-3-01
- Without light/surge voltage suppressor
For AC (50 60 Hz) 200 VAC 200VN SY100-82-3-02
S With surge voltage suppressor
1 100 VAC 110 VAC (115 VAC) 110VN SY100-82-3-03
Z With light/surge voltage suppressor
2 200 VAC 220 VAC (230 VAC) 220VN SY100-82-3-04
∗ YOZ is not available.
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ For AC voltage valves there is no “S”
option. It is already built-in to the rectifier
Caution
1. Use caution in wiring because it won't meet the IP65 (enclosure) standard if you use cord other than the
circuit. prescribed heavy-duty cord of size (ø3.5 to ø7.5). Also be sure to tighten the ground nut and holding
screw with the prescribed torque range. Tighten the ground nut and set screw within the specified range
of torque. For how to use DIN terminal (wiring procedures, procedures for changing electrical entries,
precautions, applicable cable circuit diagram), refer to back page 9.
Electrical entry 2. D type DIN connector with 9.4 mm pitch between terminals if not interchangeable.
3. To distinguish from the D type DIN connector, “N” is listed at the end of voltage symbol. (For connector
Y DIN With connector
parts without lights, “N” is not indicated. Please refer to the name plate to distinguish.)
YO terminal Without connector 4. Dimensions are completely the same as D type DIN connector.
5. When exchanging the pilot valve assembly only, “V115-D” is interchangeable with “V115-Y”. Do not
replace V114 (G, L, M) to SY115 (DIN terminal), and vice versa.

210
Made to Order Specifications:
Series SY3000/5000/7000/9000, SY300/500
M8 Connector Conforming to IEC60947-5-2
M8 Connector type conforming to IEC60947-5-2 standard.
How to Order Valve
A port size
Type of actuation
Symbol Port size Applicable series
3 Body ported
5 Base mounted - Without sub-plate -
M5 M5 SY300
Type of actuation 01 1/8 SY500
1 Normally open C4 One-touch fitting for ¯4
SY300
C5 One-touch fitting for ¯6
2 Normally closed
C6 One-touch fitting for ¯8
SY500
Series C8 One-touch fitting for ¯8
Thread type
3 SY300 N3 One-touch fitting for 5 32"
SY300 - Rc
N7 One-touch fitting for 1 4"
5 SY500
N7 One-touch fitting for 1 4" F G
SY500
N9 One-touch fitting for 5 16" N NPT
3 port valve T NPTF
(5 port valve mixed SY 5 1 3 5 WAO
-Q
mounting style)
5 port valve SY 5 2 2 0 5 WAO -Q
A, B port size
For body ported
Series Pilot type Thread piping
3 SY3000 Electrical entry
- Internal pilot Symbol Port size Applicable series
5 SY5000 WA: With M5 M5 SY3000
R External pilot connector cable
7 SY7000 01 18 SY5000
∗ Base mounted 02 18 SY7000
9 SY9000 type only.
WAO: Without
connector cable 03 38 SY9000
One-touch fitting (Metric size)
Type of actuation Note: � is for cable length.
Symbol Port size Applicable series
1 2 position single Rated voltage Please refer to Specific
C4 One-touch fitting for ¯4
Product Precautions 8. SY3000
2 2 position double For DC C6 One-touch fitting for ¯6
3 3 position closed centre 5 24 VDC C4 One-touch fitting for ¯4
4 3 position exhaust centre C6 One-touch fitting for ¯6 SY5000
6 12 VDC
5 3 position pressure centre C8 One-touch fitting for ¯8
V 6 VDC C8 One-touch fitting for ¯8 SY7000
S 5 VDC C10 One-touch fitting for ¯10
Body type
R 3 VDC C8 One-touch fitting for ¯8
2 Body ported C10 One-touch fitting for ¯10 SY9000
4 Base mounted C12 One-touch fitting for ¯10
6 Body ported, cassette type Light/surge voltage suppressor One-touch fitting (Inch size)
Note) SY9000 series is not available - Without light/surge voltage suppressor Symbol Port size Applicable series
with body ported cassette type. S With surge voltage suppressor N3 One-touch fitting for ¯ 5 32"
SY3000
With indicator light and surge voltage suppressor N7 One-touch fitting for ¯ 1 4"
Z
N3 One-touch fitting for ¯ 32"
5
Note) When placing an order for body ported R With surge voltage suppressor (Non-polar type) N7 One-touch fitting for ¯ 1 4" SY5000
solenoid valve as a single unit, U With indicator light and surge voltage suppressor (Non-polar type) N9 One-touch fitting for ¯ 5 16"
mounting bolt for manifold and gasket N9 One-touch fitting for ¯ 5 16"
are not attached. Order them SY7000
N11 One-touch fitting for ¯ 3 8"
separately, if necessary. (For details, N9 One-touch fitting for ¯ 5 16"
refer to page 56.) Manual override N11 One-touch fitting for ¯ 3 8"
SY9000
- Non-locking push type For Base Mounted
D Push-turn locking slotted type Symbol Port size Applicable series
E Push-turn locking lever type - Without sub-plate
18
01 With sub-plate
SY3000
14 SY5000
02 With sub-plate SY7000
03
38 SY7000
With sub-plate SY9000
12
04 With sub-plate SY9000
How to Order Pilot Valve Assembly

V111 5 WAO

Rated voltage Light/surge voltage suppressor


For DC - Without light/surge voltage suppressor
5 24 VDC S With surge voltage suppressor
Electrical entry Z With light/surge voltage suppressor
6 12 VDC
WAO Without connector cable R With surge voltage suppressor (Non-polar type)
V 6 VDC
WA� With connector cable U With light/surge voltage suppressor (Non-polar type)
S 5 VDC
Note: � is for cable length. Please
R 3 VDC refer to Specific Product
Precautions 8.
211
5 Port Solenoid Valve
Series SY3000/5000/7000/9000
Made to Order Body Ported
External Pilot/Fluoro Rubber for Main Value
Body Ported External Pilot Main Valve Fluoro Rubber Specifications
Applicable solenoid valves: Series SY326 0, SY526 0, SY7 26 0 Fluoro rubber is used for rubber parts of the main valve to allow use
in applications such as the following.
3 2
Model
SY 57 X20-Q
• When using a lubricant other than the recommended turbine oil,
no. 60 and there is a possibility of malfunction due to swelling of the spool
valve seals.
2 2 2
Applicable solenoid valves: Series SY34 0, SY54 0, SY74 0, SY924 0
6 6 6
Entry is the same as standard products. 3 20
Operating pressure range (MPa)
Model
no. SY 5
7 40 X90-Q
Operating pressure range –100 kPa to 0.7 9 60
Pilot pressure range 0.25 to 0.7

Entry is the same as standard products.


Dimensions: For SY320 20 20
60 60, SY560 60, SY760 60 Specifications and performance are the same as
Dimensions SY3000 becomes 6.5 mm longer standard products.
SY5000 and SY7000 becomes 10 mm longer.

External pilot port


Series Port size
SY3000 M3
SY 57 000 M5

Dimensions: For SY360, SY560, SY760


Manual override External pilot port
M3

B
SMC

A
L1
Standard valve length + L2

Dimentions/External Pilot Port Position


Series L1 dimensions L2 dimensions
SY3000 41.5 6.5
SY5000 60.4 9
SY7000 71.9 9

JIS Symbol
Body ported
2 position single 3 position closed center

2 position double 3 position exhaust center

3 position pressure center

212
Series SY
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by a label of
“Caution”, “Warning” or “Danger”. To ensure safety, be sure to observe ISO 4414 Note
1), JIS B 8370 Note 2) and other safety practices.

Caution:
. Operator error could result in injury or equipment damage.

Warning: Operator error could result in serious injury or loss of life.

Danger: In extreme conditions, there is a possible result of serious injury or loss of life.

Note 1) ISO 4414: Pneumatic fluid power — General rules relating to systems.
Note 2) JIS B 8370: General Rules for Pneumatic Equipment

Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitable of all items specified, referring to the latest catalogue information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driven objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.

Back page 1
4/5 Port Solenoid Valves/Common Precautions 1
Be sure to read before handling.

Design Design

Warning 10. About ventilation


When it is used inside a sealed control panel, etc., provide
1. Actuator drive ventilation to prevent a pressure increase caused by
When an actuator, such as a cylinder, is to be driven using a exhausted air inside the control panel or temperature rise
valve, take appropriate measures to prevent potential danger caused by the heat generated by valve.
caused by actuator operation
2. Intermediate stopping
When a 3 position closed center valve is used to stop a
Selection
cylinder at an intermediate position, accurate stopping of the
piston in a predetermined position is not possible due to the Warning
compressibility of air. Furthermore, since valves and cylinders 1. Confirm the specification
are not guaranteed for zero air leakage, it may not be possible
The products presented in this catalogue are designed only for
to hold a stopped position for an extended length of time.
use in compressed air systems (including vacuum). Do not
Contact SMC if it is necessary to hold a stopped position for
operate at pressures or temperatures, etc., beyond the range
an extended time.
of specifications, as this can cause damage or malfunction.
3. Effect of back pressure when using a (Refer to specifications.)
manifold Contact SMC when using a fluid other than compressed air
Use caution when valves are used on a manifold, as actuator (including vacuum).
malfunction due to back-pressure may occur. 2. Extended periods of continuous energisation
Special caution must be taken when using 3 position exhaust  Continuous energisation of the valve for extended periods of
center valve or when driving a single acting cylinder. To time may have an adverse effect on the solenoid valve
prevent a malfunction, implement counter measures such as performance and the peripheral equipment due to
using a single EXH spacer assembly or an individual exhaust temperature rises caused by the heat generation of the coil.
manifold. Consult with SMC if valves will be continuously energised for
4. Holding of pressure (including vacuum) extended periods of time or the energised period per day will
Since valves are subject to air leakage, they cannot be used be longer than the de-energised period. It is also possible to
for applications such as holding pressure (including vacuum) shorten the energisation period by using valves of the N.O.
in a pressure vessel. (normally open) type.

5. Cannot be used as an emergency shut off


 When solenoid valves are mounted in a control panel, employ
measures to radiate excess heat, so that temperatures
valve, etc.
remain within the valve specification range. Use special
The valves presented in this catalogue are not designed for caution when three or more stations sequentially aligned on
safety applications such as an emergency shut off valve. If the the manifold are continuously energised since this will cause
valves are used in this type of system, other reliable safety a drastic temperature rise.
assurance measures should also be adopted. (As for AC specifications, since the applicable merchandises
6. Maintenance space are ready to provide separately, contact SMC.)
The installation should allow sufficient space for maintenance
activities (removal of valve, etc.).
7. Release of residual pressure
Provide a residual pressure release function for maintenance
purpose. Especially in case of 3 position closed center valve or
perfect valve, ensure the release of residual pressure between
valve and cylinder.
8. Vacuum applications
When a valve is used for vacuum switching, etc., take
measures against the suction of external dust or other
contaminants from vacuum pads and exhaust ports, etc.
Moreover, an external pilot type valve should be used in this
case. Contact SMC in case of an internal pilot type or air
operated valve, etc.
9. About using the double solenoid type
When using the double solenoid type for the first time,
actuators may travel in an unexpected direction depending on
the switching position of a valve. Implement countermeasures
not to occur any danger by the actuator's operation.

Back page 2
4/5 Port Solenoid Valves/Common Precautions 2
Be sure to read before handling.

Selection Selection

Caution 7. Mounting orientation


Rubber seal: Refer to the specifications of each series.
1. Momentary energisation
If a double solenoid valve will be operated with momentary
energisation, it should be energised for at least 0.1 second. Mounting
However, depending on the secondary load conditions, it
should be energised until the cylinder reaches the stroke end
position, as there is a possibility of malfunction otherwise.
Warning
1. If air leakage increases or equipment does
2. Leakage voltage not operate properly, stop operation.
When using a resistor in
Check mounting conditions when air and power supplies are
parallel with the switching Switching element
Leakage
OFF voltage connected. Initial function and leakage tests should be
element or using a C-R C R performed after installation.
element (surge voltage supply Power Valve

suppressor) for protection of Leakage current


2. Instruction manual
the switching element, note Mount and operate the product after reading the manual
that leakage voltage will increase due to leakage current carefully and understanding its contents.
flowing through the resistor or C-R element. Limit the amount Also keep the manual where it can be referred to as
of residual leakage voltage to the following values: necessary.

DC coil Should be 3% or less of the rated voltage 3. Painting and coating


Warnings or specifications printed or pasted on the product
AC coil Should be 8% or less of the rated voltage should not be erased, removed or covered up.
Consult with SMC if paint is to be applied to resinous parts, as
3. Solenoid valve drive for AC with solid state this may have an adverse effect due to the paint solvent.
output (SSR, TRIAC output, etc.)
1) Voltage leakage
When using a snubber circuit (C-R element) for surge protection Piping
of the output element, very small electric current will still continue
to flow in spite of the OFF state. This results in the valve not Caution
returning. In the cases when exceeding the tolerance as shown
1. Preparation before piping
above, take measures to install a bleeder resistor.
Before piping is connected, it should be thoroughly blown out
2) Minimum allowable load (Min. load current)
with air (flushing) or washed to remove chips, cutting oil and
When the consumption current of a valve is equal or less than
other debris from inside the pipe.
the output element's the minimum allowable load volume or the
margin is small, the output element may not be switched 2. Wrapping of sealant tape
normally. Please confirm SMC. When connecting pipes and fittings, etc., be sure that chips
4. Surge voltage suppressor from the pipe thread and sealing materials do not get inside
the valve. Furthermore, when pipe tape is used, leave 1.5 to 2
If a surge protection circuit contains non-ordinary diodes such
thread ridges exposed at the end of the threads.
as Varistor, a residual voltage that is in proportion to the
protective elements and the rated voltage will remain.
Winding
Therefore, give consideration to surge voltage protection of the direction
controller. In the case of diodes, the residual voltage is
approximately 1 V. Ex
po Pipe tape
se
5. Low temperature operation ap
pr
ox
Unless otherwise indicated in the specifications for each valve, .2
thr
ea
operation is possible to –10°C, but appropriate measures ds
should be taken to avoid solidification or freezing of drainage
and moisture, etc. 3. Closed center valves
6. Using for air blow When using closed center type valves, check carefully to be
When using a solenoid valve for air blow, use an external pilot sure there are no air leaks from the piping between the valves
type.Take note that when internal pilots and external pilots are and cylinders.
used on the same manifold, the pressure drop caused by the air
blowing can have an effect on the internal pilot type valves.
Moreover, when compressed air within the pressure range of the
established specifications is supplied to the external pilot port,
and a double solenoid valve is used for air blowing, the
solenoids should normally be energised when air is being blown.

Back page 3
4/5 Port Solenoid Valves/Common Precautions 3
Be sure to read before handling.

Piping Wiring

Caution 2. Applied voltage


When electric power is connected to a solenoid valve, be
4. Screwing in
careful to apply the proper voltage. Improper voltage may
When connecting fittings to valves, tighten as indicated below.
cause malfunction or burn out the coil.
1) For M3, M5 types
3. Confirm the connections.
1. When using SMC fittings, follow the guidelines below.
After completing the wiring, confirm that the connections are
After tightening by hand, tighten an additional 1/4 (M3), 1/6
correct.
(M5) turn with a tightening tool. However, if miniature fittings
are used, tighten an additional 1/4 turn with a tightening tool
after tightening by hand. For fittings with gaskets in 2 Lubrication
locations, e.g., universal elbow or universal tee, tighten an
additional 1/2 turn.
Note) If fittings are over-tightened, air leakage may result due
Caution
1. Lubrication
to breaking of fitting threads or deformation of the
gaskets. However, if fittings are not tightened [Rubber seal]
sufficiently, loosening of the threads and air leakage and 1. The valve has been lubricated for life at the factory, and
may occur. does not require any further lubrication.
2. When fittings other than SMC fittings are used, follow the 2. In the event that it is lubricated, use class 1 turbine oil
instructions of the respective fitting manufacturer. (without additives), ISO VG32.
2) For Rc threads However, once lubrication is applied it must be continued,
as loss of the original lubricant may lead to malfunction.
Fasten with the proper tightening torques as shown below.
Contact SMC regarding class 2 turbine oil (with additives),
Tightening Torque for Piping ISO VG32.
Connection threads Proper tightening torque N·m
1/8 7 to 9
Air Supply
1/4 12 to 14
3/8
1/2
22 to 24
28 to 30
Warning
3/4 28 to 30 1. Use clean air.
1 36 to 38 Do not use compressed air which contains chemicals,
11/4 40 to 42 synthetic oils containing organic solvents, salts or corrosive
11/2 48 to 50 gases, etc., as this can cause damage or malfunction.
2 48 to 50

5. Connection of piping to products Caution


When connecting piping to a product, refer to its instruction 1. Install air filters.
manual to avoid mistakes regarding the supply port, etc. Install air filters close to valves at their upstream side. A
filtration degree of 5 µm or less should be selected.
Wiring 2. Install an air dryer, after cooler or Drain
Catch (water separator), etc.
Caution Air that includes excessive drainage may cause malfunction
1. Polarity of valves and other pneumatic equipment. To prevent this,
install an air dryer, after-cooler or water separator, etc.
When connecting power to a DC specification solenoid valve
equipped with (indicator light) surge voltage suppressor, 3. If excessive carbon dust is generated,
confirm whether or not there is polarity. If there is polarity, take eliminate it by installing mist separators at
note of the following points. the upstream side of valves.
Without built-in diode to protect polarity (including any power If excessive carbon dust is generated by the compressor, it
saving circuit): may adhere to the inside of valves and cause malfunction.
If a mistake is made regarding polarity, the diode in the valve,
the control device switching element or power supply Refer to “SMC Best Pneumatics” catalogue for compressed air
equipment, etc., may burn out. quality.
With diode to protect polarity:
If a mistake is made regarding polarity, it will not be possible to
switch the valve.

Back page 4
4/5 Port Solenoid Valves/Common Precautions 4
Be sure to read before handling.

Operating Environment Maintenance

Warning Warning
1. Do not use valves in atmospheres of 1. Perform maintenance procedures as shown
corrosive gases, chemicals, salt water, water in the instruction manual.
or steam or where there is direct contact If handled improperly, malfunction or damage of machinery or
with any of these. equipment may occur.
2. Products with IP65 enclosures (based on 2. Equipment removal and supply/exhaust of
IEC60529) are protected against dust and compressed air
water, however, these products cannot be When equipment is removed, first confirm that measures are
used in water. in place to prevent dropping of work pieces and run-away of
Take measures to prevent water and dust equipment, etc. Then cut the supply pressure and power, and
from coming from the exhaust port. exhaust all compressed air from the system using its residual
pressure release function.
3. Products compliant to IP65 satisfy the Furthermore, in the case of 3 position closed center type
specifications by mounting each product valves, compressed air will remain between valves and
properly. Be sure to read the Specific cylinders, and must be exhausted similarly.
Product Precautions for each product. When the equipment is to be started again after remounting or
4. Do not use in an explosive atmosphere. replacement, first confirm that measures are in place to
5. Do not use in locations subject to vibration prevent lurching of actuators, etc., and then confirm that the
equipment is operating normally.
or impact. Confirm the specifications in the
main section of this catalogue. 3. Low frequency operation
6.A protective cover, etc., should be used to Valves should be switched at least once every 30 days to
prevent malfunction. (Use caution regarding the air supply.)
shield valves from direct sunlight.
7.Shield valves from radiated heat generated 4. Manual override operation
by nearby heat sources. When the manual override is operated, connected equipment
will be actuated. Confirm safety before operating.
8.Employ suitable protective measures in
locations where there is contact with water
droplets, oil or welding spatter, etc. Caution
9. When solenoid valves are mounted in a 1. Drain flushing
control panel or are energised for extended
Remove drainage from air filters regularly.
periods of time, employ measures to radiate
excess heat, so that temperatures remain
within the valve specification range.

Back page 5
SY
Series
Specific Product Precautions 1
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Manual Override Operation Solenoid Valve for 200, 220 VAC Specifications

Warning Warning
 Non-locking push type [Standard] Solenoid valves with DIN terminal and L/M type plug connector
Press in the direction of the arrow AC specifications have a built-in rectifier circuit in the pilot section
to operate the DC coil.
With 200 V, 220 VAC specification pilot valves, this built-in
rectifier generates heat when energised. The surface may
become hot depending on the energised condition; therefore, do
not touch the solenoid valves.

 Push-turn locking slotted type [Type D]


While pressing, turn in the direction of the arrow.
Exhaust Throttle
If it is not turned, it can be operated the same way as the non-
locking type. Caution
With series SY, the pilot valve and main valve share a common
Locked position
exhaust inside the valve. Therefore, do not block the exhaust port
when arranging the piping.
PUSH

LOCK

Series SY3000/5000/7000/9000
Used as a 3-Port Valve

Caution Caution
When operating the locking type D with a screw driver, turn it In case of using a 5-port valve as a 3-port valve
gently using a watchmakers screw driver. Series SY3000/5000/7000/9000 can be used as normally closed
[Torque: Less than 0.1 N·m] (N.C.) or normally open (N.O.) 3-port port valves by closing one
of the cylinder ports (A or B) with a plug. However, they should be
used with the exhaust ports kept open. (Refer to pages 117 to
 Push-turn locking lever type [Type E] 182 for dedicated 3-port solenoid valve.)
While pressing, turn it the direction of the arrow.
Plug position B port A port
If it is not turned, it can be operated the same way as the non-
Configuration N.C. N.O.
locking type. Plug Plug
Number of solenoids

Locked position Single

Plug Plug
PUSH

LOCK

Double

Caution
When locking the manual override on the push-turn locking
types (D, E), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and trouble such as air leakage, etc.

Back page 6
SY
Series
Specific Product Precautions 2
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

How to Use Plug Connector Surge Voltage Suppressor

Caution Caution
1. Attaching and detaching connectors <For DC>
 To attach a connector, hold the lever and connector unit Grommet, L/M Plug Connector
between your fingers and insert straight onto the pins of the
 Standard type (With polarity)
solenoid valve so that the lever’s pawl is pushed into the
groove and locks.
With surge voltage suppressor (S)
Polarity protection diode
 To detach a connector, remove the pawl from the groove by Red (+)
pushing the lever downward with your thumb, and pull the

Coil
connector straight out.
Cover
Black (-)
Groove
Pin With light/surge voltage suppressor (Z)
Polarity protection diode
Cover
Groove Red (+)

Coil
Pin Lever
DC polar indication
Black (-)
-+ Socket
 Non-polar type
Connector Lead wire With surge voltage suppressor (R)
(-) (+)
Hook

Coil
Varistor

2. Crimping connection of lead wire and socket (+) (-)

Strip 3.2 to 3.7 mm at the end of lead wires, insert the end of With light/surge voltage suppressor (U)
the core wires evenly into the sockets, and then crimp it by a (-) (+)

Coil
crimping tool. When this is done, take care that the coverings of Varistor
the lead wires do not enter the core wire crimping area. (+) (-)
(Crimping tool: Model no. DXT170-75-1)
• Connect the standard type in accordance with the +, – polarity
indication. (The non-polar type can be used with the connections made
Core wire
crimping area Covering retainer either way.)
• Since voltage specifications other than standard 24 V and 12 VDC do
Core wire
Socket Lead wire not have diodes for polarity protection, be careful not to make errors in
0.2 to 0.33 mm2 the polarity.
Max. o.d. of covering:
• Please use caution regarding the allowable voltage fluctuation
Covering ø1.7 mm
Hook because there is about a 1 volt drop for a valve with polarity protection.
(For details, refer to the solenoid specifications for the individual
valve.)
• When wiring is done at the factory, positive (+) is red and negative (–)
3. Attaching and detaching lead wires with sockets
 Attaching  With power saving circuit
Insert the sockets into the square holes of the connector (+, – Power consumption is decreased by 1/4 by reducing the wattage
indication), and continue to push the sockets all the way in until required to hold the valve in an energised state. (Effective
they lock by hooking into the seats in the connector. energising time is over 62 ms at 24 VDC.)
Electric circuit (with power saving circuit)
(When they are pushed in, their hooks open and they are
Red (+)
locked automatically.) Then confirm that they are locked by
Timer circuit

Coil

LED
Diode
pulling lightly on the lead wires.

 Detaching 1 2
Black (–)
To detach a socket from a connector, pull out the lead wire 1: Starting current 2: Holding current

while pressing the socket’s hook with a stick having a thin tip Operating Principle
(approx. 1 mm).
With the above circuit, the current consumption when holding is redu-
If the socket will be used again, first spread the hook outward. ced to save energy. Please refer to the electric wave data below.
• Please be careful not to reverse the 3
5

Socket Connector polarity, since a diode to prevent the (In the case of SY 79 ∗∗0T, the electric
wave form of energy saving type)
reversed current is not provided for
Applied voltage
the power saving circuit. 24V
• Please use caution regarding the 0V
Hook Lead wire allowable voltage fluctuation becau-
se there is about a 0.5 volt drop due Standard
0.4W
to the transistor. (For details, refer to With power
0.1W
saving circuit
the solenoid specifications for the in- 0W
62ms
dividual valve.)
Back page 7
SY
Series
Specific Product Precautions 3
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Surge Voltage Suppressor


DIN Terminal Plug-in
With surge voltage suppressor (DS) Circuit for non-polar (FU)
(-) (+)

Coil
Coil
Varistor
Varistor
(+) (-)

With light/surge voltage suppressor (DZ) Plug-in valve has no polarity, so its possible to use for both
manifold bases for positive (SS5Y 35 -45) and negative its
3
common (SS5Y 5 -45N) types.

Coil
<For AC>
Varistor (There is no “S” option, because the generation of surge voltage
DIN terminal has no polarity. is prevented by a rectifier.)

DIN Terminal
M8 Connector
With light (DZ)
(Ground)
 Standard type (without polarity)
4
With surge voltage suppressor (S)

Coil
Diode to prevent reverse current Varistor
1 3
1 (+)
Solenoid valve side pin wiring NL: Neon light
Coil

diagram (For W type) Note) Surge voltage suppressor of varistor has residual voltage
3 (-)
corresponding to the protective element and rated voltage;
4 therefore, protect the controller side from the surge
With light/surge voltage suppressor (Z)
voltage. The residual voltage of the diode is approximately
Diode to prevent reverse current
1 3 1 V.
1 (+)
Solenoid valve side pin wiring
Coil

diagram (For WA type)


3 (-)

(Ground)
4  Non-polar type
With surge voltage suppressor (R)
1 3 1 (-) (+)
Coil

Varistor
Solenoid valve side pin wiring
3 (+) (-)
diagram (For W type)
4
With light/surge voltage suppressor (U)
1 (-) (+)
1 3
Coil

Varistor
Solenoid valve side pin wiring
3 (+) (-)
diagram (For WA type)

• In the case of standard type, connect + to 1 and – to 3 for W


type, and connect + to 4 and - to 3 for WA type, according the
polarity.
• For DC voltages other than 12 V and 24 V, incorrect wiring will
case damage to the surge suppressor circuit.
• Please use caution regarding the allowable voltage fluctuation
because there is about a 1 volt drop for a valve with polarity
protection. (For details, refer to the solenoid specifications for
the individual valve.)

Back page 8
SY
Series
Specific Product Precautions 4
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Plug Connector Lead Wire Length How to Use DIN Terminal

Caution Caution
Standard length is 300mm, but the following lengths are also Connection
available. 1. Loosen the holding screw and pull the connector out of the
solenoid valve terminal block.
How to Order Connector Assembly
2. After removing the holding screw, insert a flat head
screwdriver, etc. into the notch on the bottom of the terminal
For DC: SY100 30 4A block and pry it open, separating the terminal block and the
housing.
Without lead wire: SY100 30 A 3. Loosen the terminal screws (slotted screws) on the terminal
(with connector and 2 of sockets only) block, insert the cores of the lead wires into the terminals
according to the connection method, and fasten them securely
with the terminal screws.
• How to Order
Lead wire length 4. Secure the cord by fastening the ground nut.
Specify the part numbers of the solenoid valve - 300 mm Caution
without connector and the connector assembly 6 600 mm When making connections, take note that using other than the
with protective cover separately. 10 1000 mm
supported size (ø3.5 to ø7) heavy duty cord will not satisfy IP65
<Example> Lead wire length 2000 mm 15 1500 mm
(enclosure) standards. Also, be sure to tighten the ground nut and
20 2000 mm
For DC 25 2500 mm holding screw within their specified torque ranges.
SY3120-5LO-M5 30 3000 mm
SY100-30-4A-20 50 5000 mm Changing the entry direction
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction
(4 directions at 90° intervals).
∗ When equipped with a light, be careful not to damage the light
with the cord’s lead wires.

Precautions
Plug in and pull out the connector vertically without tilting to one side.

Compatible cable
Cord O.D.: ø3.5 to ø7
2
(Reference) 0.5mm , 2-core or 3-core, equivalent to JIS C 3306

Ground nut
Tightening torque
1.65 to 2.5 N·m Holding screw
Tightening torque
Washer 0.4 N·m

Grommet
(Rubber) Housing

(Rating symbol)
(Light mounting
Refer to table of DIN connector
part no. location)
Terminal block
Terminal screw Notch
(3 locations)
Tightening torque
0.2 to 0.25 N·m

Back page 9
SY
Series
Specific Product Precautions 5
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Series SY300, SY3000 Connector Assembly with Cover


How to Use DIN Terminal Connector
Caution
Caution Connector assembly with dust proof protective
 SMC can provide a DIN style terminal connector (body ported cover.
type, sub-plate type) for the series SY300 and SY3000. This  Effective to prevention of short circuit failure due to the entry of
cannot be assembled to a standard manifold since the DIN
foreign matter into the connector.
connector width (15.8mm) exceeds that of the valve body
 Chloroprene rubber for electrical use, which provides
(10mm). Contact SMC if you wish to use with a manifold.
outstanding weather resistance and electrical insulation, is used
Please also note: that brackets F1, F2 cannot be mounted.
for the cover material. However, do not allow contact with
cutting oil, etc.
Max.10 85.9  Simple and unencumbered appearance by adopting round-
shaped cord.

How to Order

SY100-68-A
59.5

52

40.7

Lead wire length (L)


- 300 mm
6 600 mm
10 1000 mm
86.8 15 1500 mm
20 2000 mm
25 2500 mm
15.8

10
A

30 3000 mm
50 5000 mm

Connector Assembly with Cover: Dimensions


(40) Gray
DIN Connector Part No.
(10)
Caution
(ø4.1)
(8)
(6.9)

Red Black

Without light SY100-61-1


(8)

With light
(17)
Rated voltage Voltage symbol No.
(14.5) L
24 VDC 24 V SY100-61-3-05
12 VDC 12 V SY100-61-3-06
100 VAC 100 V SY100-61-2-01
200 VAC 200 V SY100-61-2-02
110 VAC 110 V SY100-61-2-03
220 VAC 220 V SY100-61-2-04

Circuit Diagram with Light


AC circuit DC circuit
How to Order
Enter the part number for a plug connector solenoid valve without
connector together with the part number for a connector assembly
with cover.
<Example 1> Lead wire length of 2000 mm
SY3120-5LOZ-M5-Q
SY100-68-A-20
NL: Neon light LED: Light emitting diode
R: Registor R: Registor <Example 2> Lead wire length of 300 mm (standard)
SY3120-5LPZ-M5-Q
Note) Refer to page 212 for DIN connector (Y) conforming to EN-175301-
803C (former DIN 43650C). Symbol for connector assembly with cover

∗ In this case, the part number for the connector assembly with
cover is not required.

Back page 10
SY
Series
Specific Product Precautions 6
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Plug-in DIN Rail for Series SY7000/9000

Caution Caution
3
 When using a double solenoid valve (Dual body type: SY 5 245- The DIN rail used with Series SY7000 and SY9000 is stronger
FU) on the plug-in style manifold (SS5Y 35 -45(N)), two than that used with Series SY3000 and SY5000. Use this
manifold stations are required per valve. exclusive DIN rail with Series SY7000 and SY9000. Furthermore,
Output to A/B ports will be made through the manifold block on if using a DIN rail other than that supplied by SMC, refer to the
the side indicated by an arrow on the top of the solenoid valve. manifold mounting section below, and mount using the same
Therefore, arrange the piping on the side indicated by the method as prescribed for side facing and rear facing, regardless
arrow. of the mounting orientation.
Although the “T” side will not be used, plugs will not be
necessary since it is sealed with the valve.
(However, insert a plug into the A/B ports if dust intrusion is Manifold Mounting
possible. Refer to page 138.)
Caution
For Type 23, 43, 45, 45 and 60 DIN rail mounting, when
Manifold valve Solenoid valve
attaching a manifold to a mounting surface, etc., with bolts, if the
[Double, 3 position]
SS5Y 35 -45 (N) Dual body type
Output port indication entire bottom surface of the DIN rail contacts the mounting
surface in a horizontal mounting, it can be used by simply
securing both ends of the DIN rail. However, for any other
mounting method or for side facing and rear facing, etc., secure
the DIN rail with bolts at uniform intervals using the following as a
Unused A, B port guide: 2 to 5 stations at 2 locations, 6 to 10 stations at 3
A, B port in output side locations, 11 to 15 stations at 4 locations, and 16 to 20 stations at
5 locations. In addition, even in the case of a horizontal
mounting, if the mounting surface is subject to vibration, etc.,
take the same measures indicated above. If secured at fewer
Plug-in type solenoid valves consist of a non-polar solenoid valve
than the specified number of locations, warping or twisting may
and a plug-in socket. When ordering them separately, refer to the
occur in the DIN rail and manifold, causing trouble such as air
following part numbers.
leakage.
Also, when using mounting screws for the DIN rail on the bottom
[Single solenoid]
side (L3 dimension in the dimension table) of the manifold valve
[Double, 3 position] body, the height of the screw head has to be as follows.
Dual body type Type 23, 43 (SY9000): 8 mm or less
Type 45 (SY3000, 5000): 5.8 mm or less
Solenoid Valve
3
For type 60:
SY 5 140-LOU
SY3000: 4.7 mm or less
Plug in socket assembly SY5000: 5.8 mm or less
SY3000-59-2A
Solenoid Valve
SY 35 245-LOU Manifold valve body

Plug in socket assembly (2)


SY3000-59-2A

Note) Using a valve other than a non-polar type may cause trouble.

DIN rail holding screw (Round head screw)


SY3000: 4.7
SY5000: 5.8
SY7000: 8

[This is the case for type 60.]

Back page 11
SY
Series
Specific Product Precautions 7
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

One-touch Fittings Other Tubing Brands

Caution Caution
The pitch determined for each of the series SY piping ports (P, A, 1. When using other than SMC brand tubing,
B, etc.) is based on the assumption that series KJ one-touch confirm that the following specifications are
fittings will be used. For this reason, other pipe fittings may satisfied with respect to the outside diameter
interfere with each other depending on their type and size.
tolerance of the tubing.
Dimensions should be confirmed in a pipe fitting catalogue
before they are used. 1) Nylon tubing within ±0.1 mm
2) Soft nylon tubing within ±0.1 mm
• Tubing attachment/detachment for One-touch 3) Polyurethane tubing within +0.15 mm,
fittings within –0.2 mm.
1) Attaching of tubing Do not use tubing which do not meet these outside diameter
1. Take a tubing having no flaws on its periphery and cut it off tolerances. It may not be possible to connect them, or they
at a right angle. When cutting the tubing, use tubing cutters may cause other trouble, such as air leakage or the tubing
TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. pulling out after connection.
If cutting is done with tools other than tubing cutters, the
tubing may be cut diagonally or become flattened, etc.,
M8 Connector
making a secure installation impossible, and causing
problems such as the tubing pulling out after installation or Caution
air leakage. Allow some extra length in the tubing. 1. M8 connector types have an IP65 (enclosure) rating, offering
2. Grasp the tubing and push it in slowly, inserting it securely protection from dust and water. However please note: these
all the way into the fitting. products are not intended for use in water.
Select a SMC connector cable (V100-49-1-) or a FA sensor
3. After inserting the tubing, pull on it lightly to confirm that it
type connector, with M8 threaded 3 pin specifications
will not come out. If it is not installed securely all the way
conforming to Nippon Electric Control Equipment Association
into the fitting, this can cause problems such as air
Standard, NECA4202 (IEC60947-5-2). Make sure the
leakage or the tubing pulling out.
connector O.D. is 10.5mm or less when used with the Series
2) Detaching of tubing SY3000 manifold. If more than 10.5mm, it cannot be mounted
1. Push in the release button sufficiently, pushing its collar due to the size.
equally around the circumference. 2. Do not use a tool to mount the connector, as this may cause
2. Pull out the tubing while holding down the release button damage. Only tighten by hand. (0.4 to 0.6 N·m)
so that it does not come out. If the release button is not 3. The excessive stress on the cable connector will not be able to
pressed down sufficiently, there will be increased bite on satisfy the IP65 rating. Please use caution and do not apply a
the tubing and it will become more difficult to pull it out. stress of 30 N or greater.
3. When the removed tubing is to be used again, cut off the
portion which has been chewed before reusing it. If the Caution
chewed portion of the tubing is used as is, this can cause Failure to meet IP65 performance may result if using alternative
trouble such as air leakage or difficulty in removing the connectors than those shown above, or when insufficiently
tubing. tightened.
 The pitch determined for each of the series SY piping ports (A, Connector cable mounting
B, etc.) is based on the assumption that series KJ one-touch
fittings will be used. For this reason, other pipe fittings may Triangle mark
interfere with each other depending on their type and size. Arrow mark
Dimensions should be confirmed in a pipe fitting catalogue
before they are used.

Note) Connector cable should be mounted in the correct direction.


Make sure that the arrow symbol on the connector is facing the
triangle symbol on the valve when using SMC connector cable
(V100-49-1-).
Be careful not to squeeze it in the wrong direction, as problems
such as pin damage may occur.

Back page 12
SY
Series
Specific Product Precautions 8
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

M8 Connector Replacement of Pilot Valve

Caution Caution
 Connector cable Pilot valves in this series are improved to provide excellent
 Connector cable for M8 can be ordered as follows: energy saving results. However following this improvement,
these new valves are no longer compatible with the conventional
How to Order pilot valve used at the interface. Consult with SMC when you
need to exchange these pilot valves, in the case of manual
1. To order solenoid valve and connector cable at the same time.
override (marked in orange) of the adapter plate.
(Connector cable will be included in the shipment of the
solenoid valve.) New type
3 Manual override

SY 57 -Q (Blue)

-+

B
A
Electrical entry
W1, WA1: Cable length 300 mm Interface
W2, WA2: Cable length 500 mm
W3, WA3: Cable length 1000 mm
W4, WA4: Cable length 2000 mm
Ex. 1) Cable length: 300mm W7, WA7: Cable length 5000 mm
SY312-5W1ZE-C4-Q Pilot valve
Symbol for electrical entry (V111) Adapter plate

Conventional type
2. To order connector cable only
Manual override
Connector dimensions (Orange)
4 Brown: 1 Bule: 3
-+

B
A
ø9

3 1 Interface
Black: 4
33.9
L 35 10

Pilot valve
Cable length (L) No.
(SY114) Adapter plate
300 mm V100-49-1-1
500 mm V100-49-1-2
1000 mm V100-49-1-3
2000 mm V100-49-1-4
5000 mm V100-49-1-7

[Dimensions when installed]


22 33.9
14

Solenoid Valve Mounting

Caution
Mount it so that there is no slippage or deformation in
gaskets, and tighten with the tightening torque as
shown below.
Model Thread size Tightening torque
SY3000 M2 0.16 N·m
SY5000 M3 0.8 N·m
SY7000 M4 1.4 N·m
SY9000 M3 0.8 N·m

Back page 13
SY
Series
Specific Product Precautions 9
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Interface Regulator

Caution
Specifications
A1 A1 A1
Interface regulator model ARBY3000--P-2 ARBY3000-- B1 -2 ARBY5000--P-2 ARBY5000-- B1-2 ARBY7000--P-2 ARBY7000-- B1-2
Applicable solenoid valve model SY340(R) SY540(R) SY740(R)
Regulated port P A B P A B P A B
Set pressure range 0.1 to 0.7 MPa
Maximum operating pressure 0.7 MPa
Fluid Air
Ambient and fluid temperature Max. 50°C
Connection port of pressure gauge M5
With pressure gauge 46 g (05), 50 g (06) 66.8 g 110.8 g
Weight W (g)
With plug 20 g 60.4 g 103.2 g
Supply side effective area Note 3) PA,B — 2.45 mm2 — 7.61 mm2 — 13.54 mm2
Exhaust side effective areaNote 3) A,BEA,EB 4.05 mm2 3.91 mm2 11.1 mm2 10.1 mm2 15.71 mm2 15.71 mm2
Note 1) Pressurise the interface regulator from P port on the base.
Note 2) With closed center and pressure center valves, the pressure can be regulated through P port only.
Note 3) Effective area, excluding the regulated port, when a primary pressure of 0.5 MPa is supplied with regulators mounted on the solenoid valves (2 positions) and
sub-plate. Refer to “Flow Characteristics” regarding the regulated port.
Note 4) Valves for weight include gasket and mounting screws.
Note 5) With A, B ports regulated (P port controlled A, B ports regulated), the effective area (Cv factor) for the regulated port and unregulated passage (P to B or P to
A) decreases as shown in the graph below when the set pressure is 0.25 MPa or less.
(A) (B)
JIS Symbol 4 2
100 (A)(B) (B) (A)
Effective area (Cv factor)%

4 2 2 4

5 3 5 3 5 3
75 (EA) (EB) (EA) (EB) (EA) (EB)

50 1 1 1
0.1 0.15 0.2 0.25 (P) (P) (P)
Set pressure (MPa) P port regulated A port regulated B port regulated
(P controlled, (P controlled,
A port regulated) B port regulated)

How to Order Interface Regulator

ARBY3000 05 P 2 ARBY5000 00 P 2
Regulated port Regulated port
P P port P P port
A1 A port (P controlled, A port regulated) A1 A port (P controlled, A port regulated)
B1 B port (P controlled, B port regulated) B1 B port (P controlled, B port regulated)

Pressure gauge connection port Pressure gauge connection port


05 Pressure gauge (G15-10-01) [for odd number stations] 00 Pressure gauge (G15-10-01)
06 Pressure gauge (G15-10-01) [for even number stations] M1 Plug (M-5P)
M1 Plug (M-5P)
Note) For series ARBY3000 with pressure
gauge, note that the part numbers for odd
number and even number stations differ to
prevent interference between the pressure
gauges when installing on the manifold.

ARBY7000 00 P 2
Regulated port
P P port
A1 A port (P controlled, A port regulated)
B1 B port (P controlled, B port regulated)

Pressure gauge connection port


00 Pressure gauge (G15-10-01)
M1 Plug (M-5P)

Back page 14
SY
Series
Specific Product Precautions 10
Be sure to read before handling.
Refer to back page 1 through to 5 for Safety Instruction and Common Precautions.

Flow Characteristics (Conditions: Inlet pressure 0.7 MPa when 2 position solenoid valve is mounted.)

ARBY3000 A1 port regulated (PA),


P port regulated (PA, B) B1 port regulated (PB)
Outlet pressure (MPa)

Outlet pressure (MPa)


0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 50 100 150 200 250 0 50 100 150 200 250
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

ARBY5000 A1 port regulated (PA),


P port regulated (PA, B) B1 port regulated (PB)
0.6 0.6
Outlet pressure (MPa)

Outlet pressure (MPa)

0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

ARBY7000 A1 port regulated (PA),


P port regulated (PA, B) B1 port regulated (PB)
Outlet pressure (MPa)

Outlet pressure (MPa)

0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 1400
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Back page 15
EUROPEAN SUBSIDIARIES:

Austria France Netherlands Spain


SMC Pneumatik GmbH (Austria). SMC Pneumatique, S.A. SMC Pneumatics BV SMC España, S.A.
Girakstrasse 8, A-2100 Korneuburg 1, Boulevard de Strasbourg, Parc Gustave Eiffel De Ruyterkade 120, NL-1011 AB Amsterdam Zuazobidea 14, 01015 Vitoria
Phone: +43 2262-62280, Fax: +43 2262-62285 Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 Phone: +34 945-184 100, Fax: +34 945-184 124
E-mail: office@smc.at Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: info@smcpneumatics.nl E-mail: post@smc.smces.es
http://www.smc.at E-mail: contact@smc-france.fr http://www.smcpneumatics.nl http://www.smces.es
http://www.smc-france.fr

Belgium Germany Norway Sweden


SMC Pneumatics N.V./S.A. SMC Pneumatik GmbH SMC Pneumatics Norway A/S SMC Pneumatics Sweden AB
Nijverheidsstraat 20, B-2160 Wommelgem Boschring 13-15, D-63329 Egelsbach Vollsveien 13 C, Granfos Næringspark N-1366 Lysaker Ekhagsvägen 29-31, S-141 71 Huddinge
Phone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466 Phone: +49 (0)6103-4020, Fax: +49 (0)6103-402139 Tel: +47 67 12 90 20, Fax: +47 67 12 90 21 Phone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90
E-mail: post@smcpneumatics.be E-mail: info@smc-pneumatik.de E-mail: post@smc-norge.no E-mail: post@smcpneumatics.se
http://www.smcpneumatics.be http://www.smc-pneumatik.de http://www.smc-norge.no http://www.smc.nu

Bulgaria Greece Poland Switzerland


SMC Industrial Automation Bulgaria EOOD SMC Hellas EPE SMC Industrial Automation Polska Sp.z.o.o. SMC Pneumatik AG
16 kliment Ohridski Blvd., fl.13 BG-1756 Sofia Anagenniseos 7-9 - P.C. 14342. N. Philadelphia, Athens ul. Poloneza 89, PL-02-826 Warszawa, Dorfstrasse 7, CH-8484 Weisslingen
Phone:+359 2 9744492, Fax:+359 2 9744519 Phone: +30-210-2717265, Fax: +30-210-2717766 Phone: +48 22 211 9600, Fax: +48 22 211 9617 Phone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191
E-mail: office@smc.bg E-mail: sales@smchellas.gr E-mail: office@smc.pl E-mail: info@smc.ch
http://www.smc.bg http://www.smchellas.gr http://www.smc.pl http://www.smc.ch

Croatia Hungary Portugal Turkey


SMC Industrijska automatika d.o.o. SMC Hungary Ipari Automatizálási Kft. SMC Sucursal Portugal, S.A. Entek Pnömatik San. ve Tic Ltd. Sti.
Crnomerec 12, 10000 ZAGREB Budafoki ut 107-113, H-1117 Budapest Rua de Engº Ferreira Dias 452, 4100-246 Porto Perpa Tic. Merkezi Kat: 11 No: 1625, TR-80270 Okmeydani Istanbul
Phone: +385 1 377 66 74, Fax: +385 1 377 66 74 Phone: +36 1 371 1343, Fax: +36 1 371 1344 Phone: +351 22-610-89-22, Fax: +351 22-610-89-36 Phone: +90 (0)212-221-1512, Fax: +90 (0)212-221-1519
E-mail: office@smc.hr E-mail: office@smc.hu E-mail: postpt@smc.smces.es E-mail: smc-entek@entek.com.tr
http://www.smc.hr http://www.smc.hu http://www.smces.es http://www.entek.com.tr

© DiskArt™ 1988

Czech Republic Ireland Romania © DiskArt™

UK
SMC Industrial Automation CZ s.r.o. SMC Pneumatics (Ireland) Ltd. SMC Romania srl SMC Pneumatics (UK) Ltd
Hudcova 78a, CZ-61200 Brno 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Str Frunzei 29, Sector 2, Bucharest Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN
Phone: +420 5 414 24611, Fax: +420 5 412 18034 Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 Phone: +40 213205111, Fax: +40 213261489 Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064
E-mail: office@smc.cz E-mail: sales@smcpneumatics.ie E-mail: smcromania@smcromania.ro E-mail: sales@smcpneumatics.co.uk
http://www.smc.cz http://www.smcpneumatics.ie http://www.smcromania.ro http://www.smcpneumatics.co.uk

Denmark Italy Russia


SMC Pneumatik A/S SMC Italia S.p.A SMC Pneumatik LLC.
Knudsminde 4B, DK-8300 Odder Via Garibaldi 62, I-20061Carugate, (Milano) 4B Sverdlovskaja nab, St. Petersburg 195009
Phone: +45 70252900, Fax: +45 70252901 Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365 Phone.:+7 812 718 5445, Fax:+7 812 718 5449
E-mail: smc@smc-pneumatik.dk E-mail: mailbox@smcitalia.it E-mail: info@smc-pneumatik.ru
http://www.smcdk.com http://www.smcitalia.it http://www.smc-pneumatik.ru

Estonia Latvia Slovakia


SMC Pneumatics Estonia OÜ SMC Pneumatics Latvia SIA SMC Priemyselná Automatizáciá, s.r.o.
Laki 12, 106 21 Tallinn Smerla 1-705, Riga LV-1006 Námestie Matina Benku 10, SK-81107 Bratislava
Phone: +372 6510370, Fax: +372 65110371 Phone: +371 781-77-00, Fax: +371 781-77-01 Phone: +421 2 444 56725, Fax: +421 2 444 56028
E-mail: smc@smcpneumatics.ee E-mail: info@smclv.lv E-mail: office@smc.sk
http://www.smcpneumatics.ee http://www.smclv.lv http://www.smc.sk

Finland Lithuania Slovenia


SMC Pneumatics Finland Oy SMC Pneumatics Lietuva, UAB SMC industrijska Avtomatika d.o.o.
PL72, Tiistinniityntie 4, SF-02231 ESPOO Oslo g.1, LT-04123 Vilnius Mirnska cesta 7, SLO-8210 Trebnje
Phone: +358 207 513513, Fax: +358 207 513595 Phone: +386 7 3885412 Fax: +386 7 3885435
E-mail: smcfi@smc.fi Phone: +370 5 264 81 26, Fax: +370 5 264 81 26
E-mail: office@smc.si
http://www.smc.fi http://www.smc.si

OTHER SUBSIDIARIES WORLDWIDE:


ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,
CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,
NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA,
TAIWAN, THAILAND, USA, VENEZUELA

http://www.smc.eu
http://www.smcworld.com
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362