Professional Documents
Culture Documents
Considerations
GWT: 0 m
γw: 9.8 kN/m3
CUT-OFF LEVEL: 0.00 m
SOIL TYPE
layer, fsAs
Field SPT
Press.)
Layer
Layer
Thick
Depth (m)
# Start End (m) (m) Type (kN/m3) N N60 N160 (kPa) (kN)
1 0 6 6 3 S 17 3 4 6 0.0 0.0
2 6 14 8 10 C 17 2 3 3 15.8 177.2
3 14 19 5 16.5 C 17 16 21 20 70.8 495.9
4 19 21 2 20 S 17 27 36 31 67.1 188.0
Total Pile Length 21.00 (m) Ultimate Skin Resistance 861
4 2 27 S 36 6 2880 353
Capacity Estimation of Precast Pile// LRFD Page 1/1 #Version:17.8 8/11/2018 [Time]
Capacity Evaluation of Precast Driven Pile
''CONFORMING AASHTO LRFD 2007''
Considerations
GWT: 0 m
γw: 9.8 kN/m3
CUT-OFF LEVEL: 1.00 m
SOIL TYPE
layer, fsAs
Field SPT
Press.)
Layer
Layer
Thick
Depth (m)
# Start End (m) (m) Type (kN/m3) N N60 N160 (kPa) (kN)
1 0 6 6 3 S 17 3 4 6 0.0 0.0
2 6 14 8 10 C 17 2 3 3 15.8 177.2
3 14 19 5 16.5 C 17 16 21 20 70.8 495.9
4 19 22 3 20.5 S 17 27 36 31 68.8 289.1
Total Pile Length 21.00 (m) Ultimate Skin Resistance 962
4 3 27 S 36 6 2952 362
Capacity Estimation of Precast Pile// LRFD Page 1/1 #Version:17.8 8/11/2018 [Time]
Capacity Evaluation of Precast Driven Pile
''CONFORMING AASHTO LRFD 2007''
PROJECT TITLE: 2X660 MW MAITREE STPP BOREHOLE ID: DESIGN SPT
CLIENT & OWNER: BHEL/BIFPCL ANALYSED BY: PRIODEEP
Considerations
GWT: 0 m
SOIL TYPE
layer, fsAs
Field SPT
Press.)
Layer
Layer
Thick
Depth (m)
# Start End (m) (m) Type (kN/m3) N N60 N160 (kPa) (kN)
1 0 6 6 3 S 17 3 4 6 0.0 0.0
2 6 14 8 10 C 17 2 3 3 15.8 227.8
3 14 19 5 16.5 C 17 16 21 20 70.8 637.5
4 19 22 3 20.5 S 17 27 36 31 68.8 371.7
5 22 26 4 24 S 17 30 40 32 80.6 580.2
Total Pile Length 26 (m) Ultimate Skin Resistance 1817
5 4 30 S 40 6 3456 700
Capacity Estimation of Precast Pile// LRFD Page 1/1 #Version:17.8 8/11/2018 [Time]
Capacity Evaluation of Precast Driven Pile
''CONFORMING AASHTO LRFD 2007''
PROJECT TITLE: 2X660 MW MAITREE STPP BOREHOLE ID: DESIGN SPT
CLIENT & OWNER: BHEL/BIFPCL ANALYSED BY: PRIODEEP
Considerations
GWT: 0 m
γw: 9.8 kN/m3
CUT-OFF LEVEL: 1.00 m
SOIL TYPE
layer, fsAs
Field SPT
Press.)
Layer
Layer
Thick
Depth (m)
# Start End (m) (m) Type (kN/m3) N N60 N160 (kPa) (kN)
1 0 6 6 3 S 17 3 4 6 0.0 0.0
2 6 14 8 10 C 17 2 3 3 15.8 227.8
3 14 19 5 16.5 C 17 16 21 20 70.8 637.5
4 19 22 3 20.5 S 17 27 36 31 68.8 371.7
5 22 27 5 24.5 S 17 30 40 32 82.3 740.3
Total Pile Length 26.00 (m) Ultimate Skin Resistance 1977
5 5 30 S 40 6 3528 714
Capacity Estimation of Precast Pile// LRFD Page 1/1 #Version:17.8 8/11/2018 [Time]
Evan and Duncan Analysis