You are on page 1of 2

Project: BK TAN CONSULTANTS

Client: Made by Date Page


Location: Thao 25-Jan-22
Subject: DRIVEN PILE CAPACITY CALCULATION Checked Revision Job No
BKT -

Pile-cap name: M0 B1
Bored hole name: BH1

1. INPUT DATA
Ground Level of bored hole = 0.000 m D
EL2
Ground Level (after scour) EL1 = 0.000 m EL1
Bottom of pile cap Level EL2 = -5.575 m
Bottom of Pile Tip Level EL3 = -34.075 m EL4
Water Level EL4 = -2.040 m
Pile Length L = 28.500 m
Dimension of driven pile Ds = 168 mm L
Tip dimension of driven pile Dp = 0.17 m
Pile Cross-Sectional Perimeter P = 0.528 m
Pile Cross-Sectional Area As = 0.022 m2
Pile Tip Cross-Sectional Area Ap = 0.022 m2
Spacing of pile : s = 0.800 m
Factor of group pile : h = 0.877 EL3
Pile Concrete Strength f'c = 40 MPa
Concrete Unit Weight gc = 24.5 kN/m3 Dp
Depth of penetration in bearing strata(mm) Db 4075 mm
2. CALCULTION
2.1. Resistance Factor
1/gMF,comp = 0.714 Strength limit state
Resistance Factor
DA1-C1 DA1-C2
Side Resistance 1.00 0.67
Base Resistance 1.00 0.59
2.2. Shaft Resistance
For Cohesive soil: (Using the a - Method and Brown Method – Mixed Soil Profiles – SPT Data)
The normal unit side resistance:
Su is not available qs = Fvs(Ab+BbN60)
Su is available qs = a Su
where: Su : Mean undrained shear strength
a : Adhesion factor
For Cohesionless soil:
qs = Fvs(Ab+BbN60)

0 N Value Layer Thickness Soil Type Su qs Qs (KN)


0 50
NSPT N60
Number (m) "1"=Sand, "2"=Clay ( kPa) (kPa) DA1-C2 DA1-C1
-5
1 1.68 2 Clay 0 0 23.0 8.4 5 7
2 3.00 2 Clay 0 0 22.0 11.7 12 19
3 2.20 2 Clay 0 0 63.0 29.0 22 34
-10
4 2.55 2 Clay 0 0 - 17.0 15 23
5 3.00 2 Clay 12 13 - 32.7 35 52
Depth (m)

-15
6 3.00 2 Clay 19 21 - 42.3 45 67
7 3.00 2 Clay 24 27 - 49.8 53 79
-20 8 3.00 2 Clay 31 34 - 58.7 62 93
9 3.00 2 Clay 35 39 - 64.2 68 102
-25 10 4.08 2 Clay 33 37 - 62.1 89 134
11 - - - - - - -
-30 End pile 28.500 2 Clay 34 38 -
Total Qs = Negative Skin Friction( DD) = - -
Positive Skin Friction Qs = 405 608

EC7 Pile design0 1of2


Project: BK TAN CONSULTANTS
Client: Made by Date Page
Location: Thao 25-Jan-22
Subject: DRIVEN PILE CAPACITY CALCULATION Checked Revision Job No
BKT -
2.3. Tip Resistance
For Cohesive soil:
The normal unit tip resistance:
Su is available qp = 9 Su
Su is not available qp = 0.46*3.55*N60 (vibration installation method)
for which: Su : Undrained shear strength of the clay near the pile base(MPa)
For Cohesionless soil:
qp = 0.46*3.55*N60

qp Qp (KN)
(kPa) DA1-C2 DA1-C1
2968.6 38.7 65.8
2.4. Bearing Capacity of Pile
DA1-C2 DA1-C1
(KN) (Ton) (KN) (Ton)
Pile Structural Capacity: Q T = j *0.85*0.85*f' c *A s 480 49 641 65
Deducting Pile Weight PW -9 -1 -9 -1
Soil Bearing Capacity: Q r = (Q s +Q p )+DD+PW 311 32 665 68
Bearing resistance of Single Pile: 311 32 641 65
Bearing resistance of one Pile in Pile Group: 272 28 582 59

EC7 Pile design0 2of2