Protection Relays
MiCOM Range
10, 20, 30 and 40 Series Key Features
Utility
• Distance Protection
• Line Differential
• Transformer Management
• Busbar Protection
• Stand Alone Breaker Fail Protection
• Directional/Non-Directional Overcurrent
CUSTOMER BENEFITS • Feeder Management and One Box Solutions
• Voltage & Frequency Protection
•O
ne single configuration software:
MiCOM S1 Studio Industrial
•1
A/5A dual rated inputs • Motor Management
•S
calable hardware • Interconnection Protection
•F
lexible mounting options
•S
tandardized user interfaces Railway
•W
ide range of communication protocols • Feeder Management
• Transformer Management
• Distance Protection
02
Protection Relays MiCOM Range
CONTROL
Programmable Scheme Logic
Flexible logic equations as well as block logic is available in a number of
20 series relays, see figure 1.
Powerful graphical logic available in the 30 and 40 series relays allows the
user to customize the protection and control functions of the relay. It is also
used to program the functionality of the opto-isolated inputs, relay outputs,
LED and user alarms.
The Programmable Scheme Logic can be used to implement additional
supervision features, such as trip circuit supervision or implement complex Figure 1: Flexible logic for Px20
logic such as frequency restoration schemes. Schemes have been
developed capable of supervising the trip coil and circuit with the circuit
breaker open or closed.
The Px40 gate logic includes OR, AND, NOT, SR and most of logical gates
with the ability to invert the inputs and outputs, and provide feedback.
Logic timers are available even for relay contact conditioning. The system
is optimized (event driven) to ensure that the protection outputs are not
delayed by the PSL operation.
The Programmable Scheme Logic is configured using the graphical MiCOM
S1 Studio PC software, as shown in Figure 2
The Px30 logic can be created using Boolean Equations or a graphical
interface as shown in figure 3.
Figure 4: Oscillography analysis using MiCOM S1 Studio Fig 5 illustrates the flexibility with which the MiCOM range of relays can be
Software for optimum results integrated into a SCADA system as well as provide engineering data for
remote access by utility engineers.
Disturbance Records
The internal disturbance recorder will record the
sampled values of all analogue input variables SCADA Master clock
such as phase currents and voltages etc. Interface (GPS)
where applicable during a fault. Oscillographic
analysis can be performed using MiCOM S1
Studio which will provide the means to quickly
Remote Access
analyse analogue and digital signals on the MODEM
EIA232
(local access)
Px30 Px20
Px20
Px30
Figure 5:
A typical substation control system
05
Protection Relays MiCOM Range
USER INTERFACES 6
The user interface and menu text are available 1
in English, French, German and Spanish as
standard. Other languages such as for example
Russian and Italian are supported on some relays 3
depending on market requirements.
The ability to customize the menu text and alarm
5
descriptions is also supported on Px30
and Px40. 2
The front panel user interfaces, as shown in
4
Figures 6, 7 & 8 comprise:
Figure 6:
(1) A back-lit liquid crystal display (20, 30, 40 Px40 series
series) Graphic LCD display (30 series only) user interface
7 8
(2) Four fixed function LEDs (20, 40 series)
Five fixed function LEDs (30 series)
(3) Up to Four user programmable LEDs (20
series) Up to Eight user programmable LEDs 1
(40 series) Twelve user programmable LEDs
(30 series)
(4) Menu navigation and data entry keys. 5
(5) “READ” and “CLEAR” keys for viewing and
reset of alarms 2
(6) An upper cover identifying the product name,
which may be raised to view full product
model number, serial number and rating
information.
3
(7) A lower cover concealing the front
4
EIA(RS)232 port, download/monitor port and
battery compartment. Cover not available on
10
compact case.
(8) Facility for fitting a security seal Figure 7:
(9) Bay control keys up to 6 bays control (30 Compact case
user interface
series)
(10) Programmable Function keys (compact
range, 30 and 40 series)
SELF MONITORING
Comprehensive Self monitoring procedures 6
within the device ensure that internal hardware 1
and software errors are detected thus ensuring
a high degree of reliability. Automatic tests 5
are performed during start-up and cyclic self
monitoring tests are performed during operation. 2
Any deviations are stored in non-volatile memory
and the result of the fault diagnosis determines
whether a blocking of the device will occur or
whether an alarm is only issued. 3
4
Front View
OUT OF SERVICE
A
provided by an optional transparent front cover,
B X6
which can be fitted or omitted according to
F1
Px3x
F2
F4
A (including brackets)
Side View
Typical Case
Dimensions Table A B C D E F G
240 270
20-TE 103 157,5
(incl. wiring) (incl. wiring)
Px20 177
139,8. 166,4 155,2
30-TE 155
223 249,6. 156
40-TE 213,4
40-TE
260,2
Rack
227,9 253,6 177,5
84-TE 434,8
84-TE
Px30 184,5 481,6
Rack
40-TE
260,2
Surface
257,1 177,5
84-TE
481,6
Surface
40-TE 206
60-TE 309,6
270
P40 80-TE 177 413,2 240 (incl. wiring)
157,5 max
80-TE
483
Rack
Compact 294,4
Px20C /
Compact 175,6 88,5 253 162,5 294,4
Px30C 310
(incl. brack.)
Note: Maximum sizes for guidance only, for specific product information please check the relevant product documentation. (All dimensions in mm)
1 ) In addition 24TE case variant available for P132.
07
Protection Relays MiCOM Range
TECHNICAL DATA
Power supplies Digital Inputs
A wide range of power supply options are A wide range of opto input voltages are supported throughout the range
available at the ordering stage.
Auxiliary Voltage Thresholds (V)
24- 250 Vdc / 48-240 Vac > 19.2 Vdc/ac (Variant code”Z”)
Nominal Voltage Operate Range (V)
Vnom. Px20 > 19.2 Vdc/ac (Variant code”Z”)
dc ac
Ph 2 > 105 Vdc (Variant code “H”)
48- 250 Vdc / 48-240 Vac
24-250 Vdc / 48-240 Vac 19.2-300 38.4-264 > 77V (70% of Uaux. 110 Vdc; Variant code “V”)
Px20 > 154V (70% of Uaux. 220 Vdc; Variant code “W”)
Ph 2 48-250 Vdc / 48-240 Vac 38.4-300 38.4-264 Thresholds
24-60 Vdc 19-72 - Standard Variant Further Options
Px30 48-300 100-230 > 18 (Uaux. 24-250 Vdc) > 73 V (67% of Uaux. 110 Vdc)
60-250 Vdc / 100-230 Vac Px30
> 90 V (60-70% of Uaux. 125/150 Vdc)
24-48 Vdc 19-65 - > 146 V (67% of Uaux. 220 Vdc)
> 155 V (60-70% of Uaux. 220/250 Vdc)
Px40 48-110 Vdc / 30-100 Vac 37-150 24-110 Universal Opto Inputs with programmable voltage thresholds
Px40
110-250 Vdc / 100-240 Vac 87-300 80-265 24/27, 30/34, 48/54, 110/125 and 220/250 Vdc
P138
Device P114D P115 P116 P120 P121 P122 P122C P123 P125 P126 P127 P130C P132 P139 P141 P142 P143 P144 P145
CT CT Dual Rail
Powered Powered Powered
CT Inputs 4 4 4 1 4 4 4 4 1 4 4 4 4 2 4 5 5 5 5 5
VT inputs - - - - - - - - 1 1 3 3 4/5 1 4/5 3 3 3/4 42 3/4
Opto Inputs ( max)1 2 2 6 2 2 3 7 5 4 7 12 2 40 16 64 8 16 32 16 32
1 - Please note that some relays may have a limit on max. I/O when used as a combination.
3V0 measured input and allows vee connected VTs.
09
Protection Relays MiCOM Range
Device P130 P132 P139 P220 P225 P241 P242 P243 P341 P342 P343 P344 P345
CT Inputs 4 4 4 4 4 4 4 7 4 5 8 8 9
RTDs/thermistors (option) - 10/0 10/0 6/0 or 4/2 10/3 or 0/0 10/0 10/0 10/0 - 10/0 10/0 10/0 10/0
Analogue I/O (option) - 1/2 1/2 0/1 0/2 or 0/0 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Function Keys/Hotkeys X X X - - X X X X X X X X
Interlocking Logic - X X - - X X X X X X X X
Protection
Motor Protection
Short circuit 50/51 X X X X X X X X
Reacceleration 27LV X X X X X X X X - - - - -
Out of Step 55 - - - - - X X X - - - - -
Loss of load 37 X X X X X X X X - - - - -
Undercurrent 37P/37N X X X X X X X X - - - - -
Unbalance/Lock-out 30/46/86 X X X X X X X X - - - - -
Underimpedance 21 - - - - - - - - - X X X X
Pole Slipping 78 - - - - - - - - - - X X X
Loss of Field 40 - - - - - X X X - X X X X
Restricted earthfault 64 - - - - - - - - X X X X X
Ancillary Functions
Phase overcurrent 50/51P X X X X X X X X X X X X X
1 - Please note that some relays may have a limit on max. I/O when used as a combination.
10
Protection Relays MiCOM Range
DISTANCE RELAYS
Device P430C P433 P435 P436 P437 P438 P439 P441 P442 P443 P444 P445
Rail Rail
CT Inputs 4 4 4 2 4/5 3 4 4 4 4 4 4
Opto Inputs(max)1 2 52 52 28 32 28 46 8 16 24 24 24
Output Contacts(max)1 8 36 46 46 46 46 26 14 21 32 46 32
RTDs (option) - 1 1 1 1 1 1 - - - - -
Analogue I/O (option) - 1/2 1/2 1/2 1/2 1/2 1/2 - - - - -
Function Key/Hotkeys X X X - X - - X X X X X
Interlocking Logic - - - - - - X - - - - -
Protection
Distance Protection
Distance 21/21N X X X X X X X X X X X X
3 pole X X - - - - X X - - - X
Autoreclose 79
1/3 pole - - X - X - - - X X X -
Directional Power 32 X X X - X - X - - - - -
Switch on-to fault 50/27 X X X X X X X X X X X X
Mutual Compensation - - - - X - - X X X X -
Neutral admittance YN X X X - - - X - - - - -
Thermal overload 49 X X X X X X X X X X - X
Voltage/Current transformer X X X X X X X X X
VTS/CTS X X X
supervision
Capacitive voltage transformer - - - - - - X X X
CVTS - - -
supervision
Channel Aided Scheme Logic 85 X X X - X - X X X X X X
Trip Circuit Supervision TCS X X X X X X X X X X X X
InterMicom X X X X X X X X X X X X
1 - Please note that some relays may have a limit on max. I/O when used as a combination.
11
Protection Relays MiCOM Range
Device P521 P530C P532 P541 P542 P543 P544 P545 P546 P547 P630C P631 P632 P633 P634 P642 P643 P645 P721 P723 P741 P742 P743 P746
CT Inputs 4 4 4 4 4 5 9 5 9 4 6 6 8 12 15 8 12 18 2 8 4 4 4 6
VT inputs - 3 4/5 - - 4 3 4 3 - - - 1 1 1 2 4 4 - - - - - 1
Opto Inputs (max) 1 5 2 46 8 16 16 16 24 24 8 2 4 34 40 34 12 24 24 2 5 8 16 24 40
1 30
Output Contacts (max) 8 8 7 14 14 14 32 32 8 8 14 22 30 22 12 24 24 4 8 8 8 21 32
Analogue I/O (opti on) - - 1/2 - - - - - - - - - 1/2 1/2 1/2 4/4 4/4 4/4 - - - - - -
RTDs (option) - - 1 - - - - - - - - - 1 1 1 10 10 10 - - - - - -
Function Keys/Hotkeys - X X X X X X X X X X X X X X X X X - - X - X X
Interlocking Logic - X X - X X X X X X - - X X - - - - - - X - X -
Protection
Line Differential 87P X X X X X X X X X - - - - - - - - - - - - - - -
2 terminal X X X - - - - - - - - - - - - - - - - - - - - -
2/3 terminal - - - X X X X X X - - - - - - - - - - - - - - -
FO signalling X X X X X X X X X - - - - - - - - - - - - - - -
Metallic signalling X X X - - - - - - - - - - - - - - - - - - - - -
SDH/Sonet network - - - - - X X X X - - - - - - - - - - - - - - -
In -Zone transformer X - - X X X - X - - - - - - - - - - - - - - - -
nd
2 harmonic restraint X X X X X X - X - - - - - - - - - - - - - - - -
Vector Compensation X - - X X X - X - - - - - - - - - - - - - - - -
Transient Bias (CT saturation) X - - - - - - - - - - - - - - - - - - - - - - -
2 breaker configuration - - - - - - X - X - - - - - - - - - - - - - - -
Direct/Permissive Intertripping X - X X X X X X X - - - - - - - - - - - - - - -
Phase Comparison 87PC - - - - - - - - - X - - - - - - - - - - - - - -
PLC signalling - - - - - - - - - X - - - - - - - - - - - - - -
Transformer Differential 87P - - - - - - - - - - X X X X X X X X - - - - - -
Windings - - - - - - - - - - 2 2 2 3 4 2 3 5 - - - - - -
Restricted earth fault 87G/
- - - - - - - - - - - - 2 3 3 2 3 5 1 - - - - -
64
th
Overfluxing/ 5 harmonic - - - - - - - - - - X X X X X X X X - - - - - -
Overexcitation 24 - - - - - - - - - - - - X X X X X X - - - - - -
nd
2 harmonic restraint - - - - - - - - - - X X X X X X X X - - - - - -
Busbar Protection 87BB - - - - - - - - - - - - - - - - - - - X X X X X
Central unit (Nbr of Feeders) - - - - - - - - - - - - - - - - - - - No up - - up
limit to 28 to 18
1 - Please note that some relays may have a limit on max. I/O when used as a combination.
12
Protection Relays MiCOM Range
Opto Inputs(max) 5 16 24 2 5 5
Output Contacts(max) 9 14 32 4 8 8
Protection
Breaker Failure Protection 50BF X 1 1/2 - - -
2 Stage X - - - - -
Pole Discrepancy X - - - - -
Autoreclose 79 - 1 1/2 - - -
Check Sync 25 - 1 2 - - -
Ferroresonance Suppression - X X - - -
3 pole tripping - X X - - -
Overvoltage 59 - X X X X X