You are on page 1of 2

DSEGenset®

DSE4510/20 MKII SPECIFICATIONS

DC SUPPLY

AUTO START AND AUTO MAINS FAILURE


CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous

CONTROL MODULES CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing

(ALTERNATOR FREQUENCY & CAN SPEED SENSING) supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
DSE4510 MKII DSE4520 MKII during cranking.

MAXIMUM OPERATING CURRENT


85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT


51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT


35 mA at 12 V, 32 mA at 24 V

MAXIMUM DEEP SLEEP CURRENT


<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4520 MKII ONLY


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
KEY FEATURES • 3 engine maintainance alarms KEY BENEFITS at supply voltage
• Auto Start and AMF mode in one • Engine speed protection • Ultimate size to feature ratio
module (DSE4520 MKII only) • Engine hours counter • Automatically transfers between OUTPUT B (START)
10 A short term, 5 A continuous,
• J1939-75 support and CAN alarm • Engine pre-heat mains (utility) and generator at supply voltage
ignore functon • Engine run-time scheduler (DSE4520 MKII only)
• Alternator frequency & CAN speed • Engine idle control for starting & • Hours counter provides accurate AUXILIARY OUTPUTS C, D, E & F
sensing in one variant stopping information for monitoring and 2 A DC at supply voltage ­­­­
­
• Largest back-lit icon display in its • Tier 4 engine instrumentation maintenance periods GENERATOR
class screens • User-friendly set-up and button VOLTAGE RANGE
• Heated display option • Battery voltage monitoring layout for ease of use 15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
• Real time clock provides accurate • Start on low battery voltage • Multiple parameters are monitored
event logging • Configurable remote start input simultaneously which are clearly FREQUENCY RANGE
• Fully configurable via the fascia or • 1 alternative configuration displayed on the largest back-lit 3.5 Hz to 75 Hz
PC using USB communication • Comprehensive warning, electrical icon display in its class
DIMENSIONS
• Extremely efficient power save trip or shutdown protection upon • The module can be configured to OVERALL
mode fault condition suit a wide range of applications 140 mm x 113 mm x 43 mm
• 3 phase generator sensing • LCD alarm indication • Uses DSE Configuration 5.5’’ x 4.4” x 1.7”
• 3 phase mains (utility) sensing • Event log (50) Suite PC Software for simplified PANEL CUT-OUT
(DSE4520 MKII only) • Fuel solenoid pulling circuit configuration 118 mm x 92 mm
• Compatible with 600 V ph to ph • On-screen line diagram on/off • Compatible with a wide range of 4.6’’ x 3.6”
nominal systems functionality CAN engines including Tier 4 MAXIMUM PANEL THICKNESS
• Generator/load power monitoring • Configurable CAN instrumentation • Licence-free PC software 8 mm
(kW, kV A, kV Ar, pf) (10) • IP65 rating (with optional gasket) 0.3”
• Accumulated power monitoring • Water in fuel digital input offers increased resistance to water
STORAGE TEMPERATURE RANGE
(kW h, kVA h, kVAr h) • Tank bund alarm digital input ingress -40 °C to +85 °C
• Generator overload protection (kW) • Generator at rest output -40 °F to +185 °F
• Generator/load current monitoring • ECU periodic wake-up for
OPERATING TEMPERATURE RANGE
and protection information retrieval -30 °C to +70 °C
• Fuel and start outputs (configurable • Back-light power-save mode -22 °F to +158 °F
when using CAN) • Adjustable delay crank timer
-40 °C to +70 °C (for heated display variant)
• 4 configurable DC outputs • Pre/post heat functionality
-40 °F to +158 °F (for heated display variant)
• 3 configurable analogue/digital • Overload protection
inputs • Mains/generator A/C system
• 4 configurable digital inputs selection OPTIONAL PARTS
• Configurable staged loading • Output timer for external audible
outputs alarm PART PART NUMBER
IP65 Gasket 020-282

RELATED MATERIALS
TITLE PART NO.
DSE4510/20 MKII Installation Instructions 053-190
DSE4510/20 MKII Operator Manual 057-260
DSE4510/20 MKII Configuration Suite PC Manual 057-258

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457 055-207/08/17 (2)
DSEGenset®

DSE4510/20 MKII ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
AUTO START AND AUTO MAINS FAILURE EMC Generic Immunity Standard for
the Industrial Environment

CONTROL MODULES BS EN 61000-6-4


EMC Generic Emission Standard for
the Industrial Environment
(ALTERNATOR FREQUENCY & CAN SPEED SENSING)
ELECTRICAL SAFETY
BS EN 60950
The DSE4510 MKII Auto Start Control Electronic J1939 (CAN) and non- Safety of Information Technology Equipment,
Module and the DSE4520 MKII Auto electronic (alternator frequency * AVAILABLE VARIANTS including Electrical Business Equipment

Mains (Utility) Failure Control Module sensing) engine support for diesel, 4510-05 Auto start with real time clock TEMPERATURE
are suitable for a wide variety of single gas and petrol engines all in one BS EN 60068-2-1
gen-set applications. variant. With a number of flexible 4510-06 Auto start with real time clock & Ab/Ae Cold Test -30 ºC
heated display BS EN 60068-2-2
inputs, outputs and protections, the Bb/Be Dry Heat +70 ºC
Whilst maintaining functions included module can be easily adapted to suit 4520-05 Auto Mains Failure with real time
within higher end controllers, such as a wide range of applications. clock VIBRATION
BS EN 60068-2-6
generator or load power monitoring,
4520-06 Auto Mains Failure with real time Ten sweeps in each of three major axes
the DSE45xx MKII range of especially Through USB Communication both clock & heated display 5 Hz to 8 Hz at +/-7.5 mm,
compact controllers provide the user modules can be easily configured 8 Hz to 500 Hz at 2 gn
with the ultimate size to feature ratio. using the DSE Configuration Suite PC
HUMIDITY
Software or can be fully configured BS EN 60068-2-30
Monitoring engine speed, oil pressure, through the module’s front panel Db Damp Heat Cyclic 20/55 ºC
coolant temperature, frequency, editor. at 95% RH 48 Hours
BS EN 60068-2-78
voltage, current, power and fuel level, Cab Damp Heat Static 40 ºC
the modules will give comprehensive All DSE products are supported by the at 93% RH 48 Hours
engine and alternator protection. This DSE global tech­nical support team
will be indicated on the largest back-lit which gives our customers and end SHOCK
BS EN 60068-2-27
LCD icon display in its class via an users access to 24 hour system help Three shocks in each of three major axes
array of warning, electrical trip and and advice. 15 gn in 11 mS
shutdown alarms.
DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the optional sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

4 4 3

USB CONFIGURABLE DC OUTPUTS ANALOGUE DC POWER


PORT INPUTS SENDERS SUPPLY 8-35V

DEUTZ
DSE4510/20 MKII ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) DC OUTPUT GENERATOR/ DC OUTPUT GENERATOR CHARGE FUEL & START ELECTRONIC
SENSING DSE4520 MKII 1 OF 4 LOAD CURRENT DSE4510 MKII 1 OF 4 SENSING ALTERNATOR OUTPUTS ENGINE CAN
(DSE4520 MKII) DSE4520 MKII 1 OF 4 (Flexible with CAN)

D+
VOLTS VOLTS
+ + +
W/L

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N

ISSUE 2