ROOF: IBR ROOFING SHEETS ON STEEL TRUSSES


W01 W01 W01 W01 DD01 W01 W01 W01 W06
- SHEETS ON 38x38mm BATTENS AT 320mm CENTRES MAX
PA
4.5kg RA EMBEDDED AT LEAST 300mm INTO BRICKWORK WITH CONNECTING DEVICES ACCORDING TO
W07 W07 W07 fire ext P WC
TI LE W07 W07 TABLE L2, SCHEDULE 1, OF SABS 0400
LE G
S IC -ALL WEB MEMBERS TO BE MINIMUM 38x114mm GRADE 4 WITH EQUAL BAYS SMALLER
D01 whb THAN 1500mm. APPROVED BRACING MUST PREVENT BUCKLING AND KEEP TRUSSES UPRIGHT
whb -VALLEY AND HIP RAFTERS TO BE GRADE 6 50x228 SA PINE
WC WC WC WC
-LAMINATED TIMBER TO COMPLY WITH SABS 876
-50mm GLASS FIBRE INSULATION TO BE INSTALLED ON CEILING
D01 D01 D01 D01 D02 D02
MALE CONCRETE ROOF
whb
CHURCH TOILETS
D02 -CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
W07 TILES W07 -VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES
urinal

HALL
-WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION
STAGE
TILES FLOORS AND WATERPROOFING
-GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
sink MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
D01 KITCHEN -25mm THICK SCREED AND FINISHES AS INDICATED
W05 TILES
BOARD ROOM W06 -SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
TILES D01 -DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
-FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS
D02
SUNDAY
SCHOOL FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP
CLASSROOM 1 -PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED
D02 TILES
FOUNDATIONS, BRICKWORK & PARTITIONS
W04 -ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
DINING ROOM -BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
OFFICE TILES
TILES W04 ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
4.5kg -PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
fire ext W02 IN EVERY COURSE
W04 -ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL
W01 W01 W01 W01 W01 W01 W01 W01 -LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE
RAMP RAMP TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
TILES TILES
DD01 ELECTRICAL LEGEND THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS

W02 W03
ELECTRICAL LAYOUT W02 W03
-NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
-ANY PARTITION TO BE RODENT PROOF
SCALE 1:100 100W CEILING LIGHT FITTING STAIRS AND BALUSTRADES
100W WALL LIGHT FITTING -STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
-1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
FLOURESCENT LIGHT FITTING -MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
municipal sewer -MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
1 LEVER SWITCHED SOCKET OUTLET -GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS
NEW DRAINAGE
2 LEVER SWITCHED SOCKET OUTLET GLAZING
PIPE LAID TO MIN
1:40 FALL 1 LEVER SWITCH ASSEMBLY

PAVING TO STREET KERB


CONNECTING TO
MUNICIPAL SEWER
PAVING TO STREET KERB

DIMMER SWITCH -BATHROOM WINDOWS TO BE FROSTED GLASS


22.90mm BOUNDARY LINE 22.90mm BOUNDARY LINE -ALL GLAZING ON DOORS TO BE SATETY GLASS
I.E 2 WAY LEVER SWITCH ASSEMBLY -ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS
I.E I.E I.E I.E R.E I.E I.E I.E I.E I.E R.E
R.E
R.E R.E DISTRIBUTION BOARD AREA SCHEDULE

METER BOX
21.94mm BOUNDARY LINE

22.15mm BOUNDARY LINE


GROUND FLOOR AREA
STAIR LIGHT
TOTAL BUILDING AREA
ZITHUMANE STREET

STOVE POINT SITE PLAN AREA

ZITHUMANE STREET
SITE COVERAGE =33 %
TELEPHONE POINT

I.E INTERCOM DOORS & WINDOWS SCHEDULE


R.E GEYSER INSTALLATION TO COMPLY SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS

SABS 0252
DO NOT SCALE THE DRAWINGS

ELECTRICAL KEY REVISIONS


REV DATE DETAILS BY
LIGHT SWITCH

6m VEHICLE ENTRANCE
A XX/XX/XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XX

NO OBSTRUCTION
NO OBSTRUCTION

STUDIO MEM PROFESSIONAL


6mVEHICLE EXIT

ARCHITECTURAL DESIGNS
GVM HOUSE, PLEIN STREET WEST
KAREN PARK
0118
Ernest Munarini: 083 681 2497 / 082 842 1996
Tel: 012 549 3344
Fax: 086 651 5327
Email:
studiomemarch@gmail.com
SACAP Reg no: Pr Arch T1615

PROPOSED NEW BUILDING FOR


6.

RY
39

EVANGELICAL PRESBYTERIA
m

CHURCH
E D

B
m LIN

ER
N N

K
BO E

ET ERF 253 TWALA TOWNSHIP


LI OU

RE
ST
UN

TO
B

G
IN
m
D

PAV
m
AR

51

PAVING TO STREET KERB PAVING TO STREET KERB


39.02mm BOUNDARY LINE WORKING DRAWINGS
Y

6.

1.2m PEDESTRIANS ENTRANCE


NO OBSTRUCTION SCALE DATE DESIGNED BY DRAWN BY CHECKED BY
AS SHOWN 17/04/2015 M.E.M N.A M.E.M
DRAWING

ZITHUMANE STREET TITLE


ENGINEER'S
SIGNATURE

N ENGINEER'S
REF Number
CLIENT'S
SIGNATURE
DATE