US: http://submittals.us.hilti.com/PTGVol2/
CA: http://submittals.us.hilti.com/PTGVol2CA/

To consult directly with a team member regarding our anchor


fastening products, contact Hilti’s team of technical support
specialists between the hours of 7:00am – 6:00pm CST.
US: 877-749-6337 or HNATechnicalServices@hilti.com
CA: 1-800-363-4458, ext. 6 or CATechnicalServices@hilti.com

Hilti, Inc.
7250 Dallas Parkway, Suite 1000
Plano, TX 75024

1-800-879-8000
www.hilti.com
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5

3.2.5.1 Product description 3.2.5.1 Product description

HIT-ICE consists of an epoxy acrylate Injectable adhesive shall be used for 3.2.5.2 Material specifications

and hardener. It is formulated for fast installation of all reinforcing steel dowels 3.2.5.3 Technical data
curing and installation in a wide range or threaded anchor rods and inserts 3.2.5.4 Installation instructions
of solid base material temperatures. into new or existing concrete. Adhesive
3.2.5.5 Ordering information
Designed for colder environmental shall be furnished in containers which
installations, HIT-ICE adhesive is a keep component A and component B
winter formulation for base material
separate. Containers shall be designed
temperatures down to –10°F (–23°C).
to accept static mixing nozzle which
The systems consist of adhesive refill thoroughly blends component A and
packs, a mixing nozzle, a HIT dispenser component B and allows injection
and either a threaded rod, rebar, HIS-N directly into drilled hole. Only injection HIT-ICE cartridge
internally threaded insert or eyebolts. tools and static mixing nozzles as
HIT-ICE is specifically designed for recommended by manufacturer shall be LEED® Credit 4.1-Low Emitting
fastening into solid base materials used. Manufacturer’s instructions shall Materials
such as concrete or grout-filled block. be followed. Injection adhesive shall be The Leadership in Energy and
formulated to include resin and hardener Environmental Design (LEED® ) Green
Product features of HIT-ICE Building Rating systemTM is the nationally
to provide optimal curing speed as well accepted benchmark for the design,
• Small edge distance and anchor
as high strength and stiffness. Typical construction and operation of high
spacing allowance
curing time at 68°F shall be 1 hour for performance green buildings.
• Mixing tube provides proper
HIT-ICE. Injection adhesive shall be
mixing and accurate dispensing
of mixed resin HIT-ICE, as furnished by Hilti.
• Contains no styrene and virtually Anchor rods shall be end stamped
odorless to show the grade of steel and overall
• Cures quickly over a large range of rod length. Anchor rods shall be
base material temperatures
manufactured to meet the following
• Excellent weathering resistance requirements:
and resistance to high tempera- 3.2.5
tures 1. ISO 898 Class 5.8; 2. ASTM A193,
• High load capacities Grade B7 high strength carbon steel
Guide specifications anchor; 3. AISI 304 or AISI 316 stainless
steel, meeting the requirements of
Master format section:
ASTM F593 condition CW.
Previous 2004 Format
Special order length HAS Rods may
03250 03 16 00 Concrete
vary from standard product.
anchors
Related Sections: Nuts and washers shall be furnished
to meet the requirements of the above
03200 03 20 00 Concrete anchor rod specifications.
reinforcing
05050 05 50 00 Metal
fabrications
05120 05 10 00 Structural metal
framing

3.2.5.2 Material specifications


Table 1 - Material properties of cured HIT-ICE adhesive
Compressive strength 72 MPa 10,440 psi
Tensile strength 12 MPa 1,740 psi
Water absorption DIN 53495 2.4%
Electrical resistance DIN/VDE 0303T3 2x1011 OHM/cm 5.1x1011 OHM/in.

For material specifications for anchor rods and inserts, please refer to section 3.2.8.

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 209
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Table 2 - Hilti HAS/HIT-V Rod installation specifications installed with Hilti HIT-ICE adhesive system
Setting Nominal anchor diameter
Symbol Units
information 3/8 1/2 5/8 3/4 7/8 1 1-1/4
Nominal bit diameter do in. 7/16 9/16 11/16 13/16 15/16 1-1/16 1-1/2
Standard effective in. 3-1/2 4-1/4 5 6-5/8 7-1/2 8-1/4 12
hef,std
embedment (mm) (90) (110) (125) (170) (190) (210) (305)
Installation torque ft-lb 18 30 75 150 175 235 400
Tinst
Embedment ≥ hef,std (Nm) (24) (41) (102) (203) (237) (319) (540)
Installation torque ft-lb 15 20 50 105 125 165 280
Tinst
Embedment < hef,std (Nm) (20) (27) (68) (142) (169) (224) (375)
in. 5-1/2 6-1/4 7 8-5/8 9-1/2 10-1/2 15
hef = hnom
Minimum base (mm) (140) (160) (180) (220) (240) (270) (380)
material thickness in. 1.0 hef+2 1.0 hef+2 1.0 hef+2 1.0 hef+2 1.0 hef+2 1.0 hef+2-1/4 1.0 hef+3
hef ≠ hnom
(mm) (hef+51) (hef+51) (hef+51) (hef+51) (hef+51) (hef+57) (hef+76)

Table 3 - Hilti HIS-N and HIS-RN installation specifications


Thread size
Setting information Symbol Units
3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC
Outside diameter of insert d in. 0.65 0.81 1.00 1.09
Nominal bit diameter do in. 11/16 7/8 1-1/8 1-1/4
in. 4-3/8 5 6-3/4 8-1/8
Effective embedment hef
(mm) (110) (125) (170) (205)
minimum in. 3/8 1/2 5/8 3/4
Thread engagement hs
maximum in. 15/16 1-3/16 1-1/2 1-7/8
ft-lb 15 30 60 100
Installation torque Tinst
(Nm) (20) (40) (81) (136)
in. 5.9 6.7 9.1 10.6
Minimum concrete thickness hmin
(mm) (150) (170) (230) (270)

Table 4 - Rebar installation specifications with Hilti HIT-ICE adhesive system


Setting Rebar size
Symbol Units
information No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No. 9 No. 10 No. 11
Nominal bit diameter1 do in. 1/2 5/8 3/4 7/8 1 1-1/8 1-3/8 1-1/2 1-9/16
1 1 Rebar diameters may vary. Use the smallest drill bit which will accomodate the rebar.

Figure 1 — Figure 2 — Table 5 - CA rebar installation specifications with Hilti HIT-ICE c


Hilti HAS/HIT-V rod Hilti HIS-N and HIS-RN adhesive anchor system
specifications specifications Rebar size 10M 15M 20M 25M 30M 35M
do Drill bit diameter1,2 14 mm 3/4" 24mm 1-1/8" 37mm 1-9/16"
1 Rebar diameters may vary. Use smallest drill bit which will accommodate rebar.
2 Hilti matched tolerance carbide tipped drill bits

210 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Table 6 - Hilti HIT-ICE allowable and ultimate bond/concrete capacity for Hilti HIT-V/HAS rods in normal-weight concrete1,2
HIT-ICE HIT-ICE
allowable bond/concrete capacity ultimate bond/concrete capacity

Nominal Tensile Shear Tensile Shear


anchor Effective ƒ'c = 2,000 psi ƒ'c = 4,000 psi ƒ'c = 2,000 psi ƒ'c = 4,000 psi ƒ'c = 2,000 psi ƒ'c = 4,000 psi ƒ'c = 2,000 psi ƒ'c = 4,000 psi
diameter embedment (13.8 MPa) (27.6 MPa) (13.8 MPa) (27.6 MPa) (13.8 MPa) (27.6 MPa) (13.8 MPa) (27.6 MPa)
in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
1-3/4 720 1,265 1,395 1,970 2,710 4,750 4,175 5,900
(44) (3.2) (5.6) (6.2) (8.8) (12.1) (21.1) (18.6) (26.2)
3-1/2 1,895 2,705 3,335 4,715 7,120 10,160 10,000 14,140
3/8
(89) (8.4) (12.0) (14.8) (21.0) (31.7) (45.2) (44.5) (62.9)
5-1/4 2,635 2,800 6,120 8,655 9,880 10,510 18,360 25,960
(133) (11.7) (12.5) (27.2) (38.5) (44.0) (46.8) (81.7) (115.5)
2-1/8 1,220 1,575 1,980 2,800 4,580 5,910 5,940 8,400
(54) (5.4) (7.0) (8.8) (12.5) (20.4) (26.3) (26.4) (37.4)
4-1/4 2,725 3,935 5,150 7,280 10,220 14,760 15,440 21,840
1/2
(108) (12.1) (17.5) (22.9) (32.4) (44.5) (65.7) (68.7) (97.1)
6-3/8 4,300 5,295 9,455 13,375 16,140 19,860 28,360 40,120
(162) (19.1) (23.6) (42.1) (59.5) (71.8) (88.3) (126.2) (178.5)
2-1/2 1,620 1,985 2,460 3,480 6,090 7,460 7,380 10,440
(64) (7.2) (8.8) (10.9) (15.5) (27.1) (33.2) (32.8) (46.4)
5 4,395 5,250 7,350 10,390 16,480 19,690 22,040 31,160
5/8
(127) (19.5) (23.4) (32.7) (46.2) (73.3) (87.6) (98.0) (138.6)
7-1/2 6,025 8,225 13,495 19,080 22,595 30,850 40,480 57,240
(191) (26.8) (36.6) (60.0) (84.9) (100.5) (137.2) (180.0) (254.6)
3-3/8 2,365 3,925 5,435 7,680 8,870 14,720 16,295 23,040
(86) (10.5) (17.5) (24.2) (34.2) (39.5) (65.5) (72.5) (102.5)
6-5/8 4,655 8,885 12,270 17,355 17,460 33,330 36,800 52,060
3/4
(168) (20.7) (39.5) (54.6) (77.2) (77.7) (148.3) (163.7) (231.6)
10 9,515 12,140 22,755 32,180 35,695 45,530 68,260 96,540
3.2.5
(254) (42.3) (54.0) (101.2) (143.1) (158.8) (202.5) (303.6) (429.4)
3-3/4 3,080 4,800 6,705 9,480 11,555 18,000 20,105 28,430
(95) (13.7) (21.4) (29.8) (42.4) (51.4) (80.1) (89.4) (126.5)
7-1/2 7,845 11,020 15,960 22,575 29,430 41,000 47,880 67,720
7/8
(191) (34.9) (49.0) (71.0) (100.4) (130.9) (182.3) (213.0) (301.2)
11-1/4 13,330 16,645 29,330 41,475 49,990 62,425 87,980 12,4420
(286) (59.3) (74.0) (130.5) (184.5) (222.4) (277.7) (391.4) (553.4)
4-1/8 3,445 4,865 8,265 11,685 12,920 18,250 24,790 35,050
(105) (15.3) (21.6) (36.8) (52.0) (57.5) (81.2) (110.3) (155.9)
8-1/4 8,330 11,635 19,690 27,840 31,250 43,640 59,060 83,520
1
(210) (37.1) (51.8) (87.6) (123.8) (139.0) (194.1) (262.7) (371.5)
12-3/8 15540 19,525 36,170 51,150 58,280 73,220 108,500 153,440
(314) (69.1) (86.8) (160.9) (227.5) (259.3) (325.7) (482.6) (682.5)
6 4645 7,000 14,760 20,870 17,430 26,265 44,280 62,610
(152) (20.7) (31.1) (65.7) (92.8) (77.5) (116.8) (197.0) (278.5)
12 15,490 20,770 38,615 54,610 58,085 77,900 115,840 163,820
1-1/4
(305) (68.9) (92.4) (171.8) (242.9) (258.4) (346.5) (515.3) (728.7)
15 19,210 26,815 53,960 76,315 72,040 100,560 161,880 228,940
(381) (85.5) (119.3) (240.0) (339.5) (320.5) (447.3) (720.1) (1018.4)
1 Influence factors for spacing and/or edge distance are applied to concrete/bond values above, and then compared to the steel value. The
lesser of the values is to be used for the design.
2 For hef ≥ hef,std average ultimate concrete shear capacity based on Strength Design method. For hef < hef,std average ultimate concrete shear
values based on testing.

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 211
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Table 7 - Allowable steel strength for Hilti HIT-V and HAS threaded rods1

Nominal HIT-V HAS-E HAS-E B7 HAS-R Stainless Steel


anchor ASTM A307 Grade A2 ISO 898 Class 5.82 ASTM A193 Grade B7 ASTM F595 - AISI 304/316 SS
diameter Tensile Shear Tensile Shear Tensile Shear Tensile Shear
in. lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
2,185 1,125 2,640 1,360 4,555 2,345 4,555 2,345
3/8
(9.7) (5.0) (11.7) (6.0) (20.3) (10.4) (20.3) (10.4)
3,885 2,000 4,695 2,420 8,095 4,170 8,095 4,170
1/2
(17.3) (8.9) (20.9) (10.8) (36.0) (18.5) (36.0) (18.5)
6,075 3,130 7,340 3,780 12,655 6,520 12,655 6,520
5/8
(27.0) (13.9) (32.6) (16.8) (56.3) (29.0) (56.3) (29.0)
8,750 4,505 10,570 5,445 18,225 9,390 18,225 9,390
3/4
(38.9) (20.0) (47.0) (24.2) (81.1) (41.8) (81.1) (41.8)
- - 14,385 7,410 24,805 12,780 24,805 12,780
7/8
- - (64.0) (33.0) (110.3) (56.8) (110.3) (56.8)
15,550 8,010 18,790 9,680 32,400 16,690 32,400 16,690
1
(69.2) (35.6) (83.6) (43.1) (144.1) (74.2) (144.1) (74.2)
- - 29,360 15,125 50,620 26,080 50,620 26,080
1-1/4
- - (130.6) (67.3) (225.2) (116.0) (225.2) (116.0)
1 Steel strength as defined in AISC Manual of Steel Construction (ASD):
Tensile = 0.33 x Fu x Nominal Area
Shear = 0.17 x Fu x Nominal Area
2 HIT-V and HAS-E threaded rods are considered brittle steel elements. HIT-V does not comply with percent elongation requirements of
ASTM A307 Grade A steel. HAS-E does not comply with % elongation requirements of ISO 898-1.

Table 8 - Ultimate steel strength for Hilti HIT-V and HAS threaded rods1

Nominal HIT-V HAS-E HAS-E B7 HAS-R Stainless Steel


anchor ASTM A307 Grade A2 ISO 898 Class 5.82 ASTM A193 Grade B7 ASTM F593 - AISI 304/316 SS
diameter Yield Tensile Shear Yield Tensile Shear Yield Tensile Shear Yield Tensile Shear
in. lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
2,905 4,970 2,980 4,495 6,005 3,600 8,140 10,350 6,210 5,040 8,280 4,970
3/8
(12.9) (22.1) (13.3) (20.0) (26.7) (16.0) (36.2) (46.0) (27.6) (22.4) (36.8) (22.1)
5,320 8,835 5,300 8,230 10,675 6,405 14,900 18,405 11,040 9,225 14,725 8,835
1/2
(23.7) (39.3) (23.6) (36.6) (47.5) (28.5) (66.3) (81.9) (49.1) (41.0) (65.5) (39.3)
8,475 13,805 8,285 13,110 16,680 10,010 23,730 28,765 17,260 14,690 23,010 13,805
5/8
(37.7) (61.4) (36.9) (58.3) (74.2) (44.5) (105.6) (128.0) (76.8) (65.3) (102.4) (61.4)
12,545 19,880 11,930 19,400 24,025 14,415 35,125 41,420 24,850 15,055 28,165 16,900
3/4
(55.8) (88.4) (53.1) (86.3) (106.9) (64.1) (156.2) (184.2) (110.5) (67.0) (125.3) (75.2)
- - - 26,780 32,695 19,615 48,480 56,370 33,825 20,775 38,335 23,000
7/8
- - - (119.1) (145.4) (87.3) (215.6) (250.7) (150.5) (92.4) (170.5) (102.3)
22,715 35,345 21,205 35,130 42,705 25,625 63,600 73,630 44,180 27,255 50,070 30,040
1
(101.0) (157.2) (94.3) (156.3) (190.0) (114.0) (282.9) (327.5) (196.5) (121.2) (222.7) (133.6)
- - - 56,210 66,730 40,035 101,755 115,050 69,030 43,610 78,235 46,940
1-1/4
- - - (250.0) (296.8) (178.1) (452.6) (511.8) (307.1) (194.0) (348.0) (208.8)
1 Steel strength as defined in AISC Manual of Steel Construction 2nd Ed. (LRFD):
Yield = F y x Tensile stress Area
Tensile = 0.75 x Fu x Nominal Area
Shear = 0.45 x Fu x Nominal Area
2 HIT-V and HAS-E threaded rods are considered brittle steel elements. HIT-V does not comply with percent elongation requirements of ASTM
A307 Grade A steel. HAS-E does not comply with % elongation requirements of ISO 898-1.

212 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Table 9 - Hilti HIT-ICE allowable bond or concrete capacity and steel strength for Hilti HIS-N and HIS-RN inserts1
HIT-ICE allowable
Allowable bolt strength2
bond/concrete capacity
ASTM A325 ASTM F593
carbon steel stainless steel
Effective
Thread embedment Tensile Shear Tensile1 Shear1 Tensile1 Shear1
size. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
4-3/8 2,750 1,605 4,370 2,250 3,645 1,875
3/8-16 UNC
(110) (12.2) (7.1) (19.4) (10.0) (16.2) (8.3)
5 4,195 3,040 7,775 4,005 6,480 3,335
1/2-13 UNC
(127) (18.7) (13.5) (34.6) (17.8) (28.8) (14.8)
6-5/8 6,700 4,575 12,150 6,260 10,125 5,215
5/8-11 UNC
(168) (29.8) (20.4) (54.0) (27.8) (45.0) (23.2)
8-1/4 7,855 6,305 17,495 9,010 12,395 6,385
3/4-10 UNC
(210) (34.9) (28.0) (77.8) (40.1) (55.1) (28.4)

Table 10 - Hilti HIT-ICE ultimate bond or concrete capacity and steel strength for Hilti HIS-N and HIS-RN inserts1
HIT-ICE ultimate
Ultimate bolt strength2
bond/concrete capacity2
ASTM A325 ASTM F593
Effective carbon steel stainless steel
Thread embedment Tensile Shear Tensile1 Shear1 Tensile1 Shear1
size. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
4-3/8 11,000 6,425 9,935 5,960 8,280 4,970
3/8-16 UNC
(110) (48.9) (28.6) (44.2) (26.5) (36.8) (22.1)
5 16,790 12,170 17,665 10,600 14,720 8,835
1/2-13 UNC
(127) (74.7) (54.1) (78.6) (47.2) (65.5) (39.3)
6-5/8 26,795 18,310 27,610 16,565 23,010 13,805
5/8-11 UNC
(168) (119.2) (81.5) (122.8) (73.7) (102.4) (61.4)
8-1/4 31,430 25,215 39,760 23,855 28,165 16,900
3/4-10 UNC 3.2.5
(210) (139.8) (112.2) (176.9) (106.1) (125.3) (75.1)
1 Use lower value of either bond, concrete capacity or steel strength. Minimum concrete compressive strength ƒ'c is 2,000 psi.
2 Steel values in accordance with AISC
ASTM A325 bolts Fy = 92 ksi , Fu = 120 ksi
ASTM F593 (AISI 304/316) Fy = 65 ksi, Fu = 100 ksi for 3/8- through 5/8-in.
Fy = 45 ksi, Fu = 85 ksi for 3/4-in.
Allowable load values Ultimate load values
Tension = 0.33 x Fu x Anom Tension = 0.75 x Fu x Anom
Shear = 0.17 x Fu x Anom Shear = 0.45 x Fu x Anom

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 213
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Table 11 - Hilti HIT-ICE allowable and ultimate bond/concrete capacity for Hilti HAS/HIT-V rods installed in 3,000 psi
structural sand-lightweight concrete

Nominal anchor Effective Allowable bond/concrete capacity1 Ultimate bond/concrete capacity


diameter embedment lb (kN) lb (kN)
in. in. (mm) Tensile Shear Tensile Shear
1-3/4
745 (3.3) 1,285 (5.7) 2,980 (13.3) 5,150 (22.9)
(44)
3/8
3-1/2
1,220 (5.4) 1,580 (7.0) 4,920 (21.9) 6,320 (28.1)
(89)
2-1/8
975 (4.3) 2,130 (9.5) 3,900 (17.3) 8,520 (37.9)
(54)
1/2
4-1/4
1,210 (5.4) 2,910 (12.9) 4,840 (21.5) 11,640 (51.8)
(108)
2-1/2
5/8 1,200 15.3) 2,480 (11.0) 4,800 (21.4) 9,920 (44.1)
(63)
3-3/8
3/4 1,760 (7.8) 4,000 (17.8) 7,040 (31.3) 15,985 (71.1)
(86)
1 Influence factors for spacing and/or edge distance are applied to allowable concrete/bond values above, and then compared to the allowable steel value.
The lesser of these values is to be used for design.

Table 12 - Allowable loads for anchorage of exterior sill plates with Hilti HIT-ICE1,2,3,4
Nominal anchor Effective edge distance Tension Shear lb (kN)
diameter embedment
in. in. (mm) in. (mm) lb (kN) Load II to edge Load ⊥ to edge
4-1/4 1-3/4 (45) 1,280 (5.3) 1,445 (6.4) 400 (1.8)
1/2
(108) 2-3/4 (70) 1,800 (8.1) 2,100 (9.5) 845 (3.8)
5 1-3/4 (45) 1,700 (7.6) 1,445 (6.4) 400 (1.8)
5/8
(127) 2-3/4 (70) 2,725 (12.1) 2,455 (10.9) 960 (4.3)
1 Allowable loads calculated using a factor of safety of 4.
2 Allowable loads are based on concrete capacity. The steel strength must be checked.
3 A wood 2x4 exterior plate has a 1-3/4 inch edge distance. A 2x6 has a 2-3/4 inch edge distance.
4 Minimum concrete compressive strength is 2,000 psi.

Table 13 - Allowable loads for anchorage to the top of grout-filled block walls with Hilti HIT-ICE1,2,3,4
Nominal anchor Effective Edge distance Tension Shear lb (kN)
diameter embedment
in. in. (mm) in. (mm) lb (kN) Load II to edge Load ⊥ to edge
4-1/4 1-3/4 (45) 1,120 (5.0) 1,425 (6.3) 560 (2.5)
1/2
(108) 2-3/4 (70) 1,440 (6.4) 2,085 (9.3) 1,110 (4.9)
5 1-3/4 (45) 1,475 (6.5) 1,800 (8.0) 680 (3.0)
5/8
(127) 2-3/4 (70) 1,630 (7.2) 3,070 (13.7) 1,110 (4.9)
1 Allowable loads calculated using a factor of safety of 5.
2 Allowable loads are based on masonry capacity. The steel strength must be checked.
3 Minimum edge distance is 1-3/4 inches.
4 Minimum masonry prism strength is 1,500 psi.

214 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Table 14 - Hilti HIT-ICE allowable loads for threaded rods in grout-filled concrete masonry units1, 2, 3, 4

Nominal Distance from


anchor Effective edge Tension5,6 Shear lb (kN)5,6
diameter embedment HAS-E HAS-E B7 HAS-R
in. in. (mm) in. (mm) lb (kN) ISO 898 Class 5.5 ASTM A193 Grade B7 AISI 304 / 316
3-1/2 4 (102)
3/8 1,550 (6.9) 1360 (6.0) 2020 (9.0) 1875 (8.3)
(89) ≥12 (305)
4-1/4 4 (102) 2,020 (9.0) 2,020 (9.0) 2,020 (9.0)
1/2 1,785 (7.9)
(108) ≥12 (305) 2,420 (10.8) 4,170 (18.5) 3,335 (14.8)
5 4 (102) 2,020 (9.0) 2,020 (9.0) 2,020 (9.0)
5/8 2,265 (10.1)
(127) ≥12 (305) 3,780 (16.8) 5,625 (25.0) 5,215 (23.2)
6-5/8 4 (102) 2,020 (9.0) 2,020 (9.0) 2,020 (9.0)
3/4 3,740 (16.6)
(168) ≥12 (305) 5,445 (24.2) 5,625 (25.0) 5,625 (25.0)

Table 15 - Hilti HIT-ICE ultimate loads for threaded rods in grout-filled concrete masonry units1, 2, 3, 4

Distance
Nominal from edge Tension lb (kN)5,6 Shear lb (kN)5,6
anchor Effective HAS-E HAS-E B7 HAS-E HAS-E B7
diameter embedment ISO 898 ASTM A193 HAS-R ISO 898 ASTM A193 HAS-R
in. in. (mm) in. (mm) Class 5.5 Grade B7 AISI 304 / 316 Class 5.5 Grade B7 AISI 304 / 316
3-1/2 4 (102)
3/8 6,005 (26.7) 6,200 (27.6) 6,200 (27.6) 3,605 (16.0) 6,210 (27.6) 4,970 (22.1)
(90) ≥12 (305)
4-1/4 4 (102) 8,075 (35.9) 8,075 (35.9)
1/2 7,140 (31.8) 7,140 (31.8) 7,140 (31.8) 6,405 (28.5)
(108) ≥12 (305) 11,040 (49.1) 8,835 (39.3)
5 4 (102) 8,075 (35.9) 8,075 (35.9) 8,075 (35.9)
5/8 9,060 (40.3) 9,060 (40.3) 9,060 (40.3)
(127) ≥12 (305) 10,010 (44.2) 17,260 (76.8) 13,805 (61.4)
6-5/8 4 (102) 8,075 (35.9) 8,075 (35.9) 8,075 (35.9)
3/4 14,970 (66.6) 14,970 (66.6) 14,970 (66.6)
(168) ≥12 (305) 14,415 (64.1) 22,500 (100.1) 16,800 (75.2) 3.2.5
1 Values are for lightweight, medium-weight or normal-weight concrete masonry units conforming to ASTM C90 with 2,000 psi grout conforming to ASTM C476.
2 Embedment depth is measured from the outside face of the concrete masonry unit.
3 Values are for anchors located in the grouted cell, head joint, bed joint, T-joint, cross web or any combination of the above.
4 Values for edge distances between 4 inches and 12 inches can be calculated by linear interpolation.
5 Loads are based on the lesser of bond strength, steel strength or base material strength.
6 Steel values in accordance with AISC
Allowable load values Ultimate load values
Tension = 0.33 x Fu x Anom Tension = 0.75 x Fu x Anom
Shear = 0.17 x Fu x Anom Shear = 0.45 x Fu x Anom

Figure 3 - Anchor spacing and edge distance

Edge distance for shear and tension:


Grout-filled, normal-weight and lightweight block
ccr = 12 in. minimum from free edge
cmin = 4 in. minimum from free edge

Anchor spacing for shear and tension:


Grout-filled, normal-weight and lightweight block
scr = smin = maximum (1) anchor per cell and minimum 8 inches
center-to-center spacing between anchors

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 215
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Table 16 - Hilti HIT-ICE ultimate bond capacity and steel strength for rebar in concrete
Concrete compressive strength
Grade 60 rebar
ƒ'c = 2,000 psi (13.8 MPa) ƒ'c = 4,000 psi (27.6 MPa)
Embed. at Embed. at Embed. at Embed. at
Ultimate ultimate load ultimate load Ultimate ultimate load ultimate load
Effective bond = to yield = to tensile bond = to yield = to tensile Yield Tensile
Rebar embedment strength strength1 strength1 strength strength1 strength1 strength strength
size in. (mm) lb (kN) in. (mm) in. (mm) lb (kN) in. (mm) in. (mm) lb (kN) lb (kN)
1-1/2 2,500 3,800
(38) (11.1) (16.9)
3-1/2 6,300 3-3/4 5-1/2 8,200 2-3/4 4-1/4 6,600 9,900
#3
(89) (28.0) (95.3) (139.7) (36.5) (69.9) (108.0) (29.4) (44.0)
7 12,600 16,500
(178) (56.0) (73.4)
2 4,200 6,000
(51) (18.7) (26.7)
4 9,000 5-1/2 8 11,800 4-1/4 6-1/4 12,000 18,000
#4
(102) (40.0) (139.7) (203.2) (52.5) (108.0) (158.8) (53.4) (80.1)
8 18,000 23,600
(203) (80.1) (105.0)
2-1/2 5,600 6,900
(64) (24.9) (30.7)
5 13,500 7 10-1/4 17,700 5-1/4 8 18,600 27,900
#5
(127) (60.1) (177.8) (260.4) (78.7) (133.4) (203.2) (82.7) (124.1)
10 27,000 35,300
(254) (120.1) (157.0)
3-1/2 10,200 12,800
(90) (45.4) (56.9)
7 22,100 8-1/2 12-3/4 28,900 6-1/2 9-3/4 26,400 39,600
#6
(178) (98.3) (215.9) (323.9) (128.6) (165.1) (247.7) (117.4) (176.2)
14 44,200 57,700
(356) (196.6) (256.7)
3-3/4 10,700 15,800
(95) (47.6) (70.3)
7-1/2 27,100 10 15 35,300 7-3/4 11-1/2 36,000 54,000
#7
(190) (120.6) (254.0) (381) (157.0) (196.9) (292.1) (160.1) (240.2)
15 54,200 70,700
(380) (241.1) (314.5)
4 14,100 18,100
(102) (62.7) (80.5)
8 32,500 11-3/4 17-1/2 42,400 9 13-1/2 47,450 71,100
#8
(204) (144.6) (298.5) (444.5) (188.6) (228.6) (342.9) (211.1) (316.3)
16 65,000 84,800
(408) (289.1) (377.2)
5 16,700 21,800
(127) (74.3) (97.0)
10 47,400 12-3/4 19 61,800 10 15-3/4 60,000 90,000
#9
(254) (210.9) (323.9) (482.6) (274.9) (254.0) (400.1) (266.9) (400.4)
18 85,300 111,300
(457) (379.4) (495.1)
6 23,300 32,400
(152) (103.6) (144.1)
12 59,600 15-1/2 23 77,700 12 17-3/4 76,200 114,300
#10
(304) (265.1) (393.7) (584.2) (345.6) (304.8) (450.9) (339.0) (508.5)
20 99,300 129,600
(508) (441.7) (576.5)
7 32,000 41,300
(178) (142.3) (183.7)
14 75,800 17-1/4 26 99,000 13-1/2 20 93,600 140,400
#11
(356) (337.2) (438.2) (660.4) (440.4) (342.9) (508.0) (416.4) (624.6)
20 108,400 141,400
(508) (482.2) (629.0)
1 Based on comparison of average ultimate adhesive bond test values versus minimum yield and ultimate tensile strength of rebar with no
consideration of spacing or edge distance; for more information, contact Hilti.

216 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Table 17 - Hilti HIT-ICE bond capacity and steel strength for CA rebar in concrete1,2 c
Strength Properties
HIT-ICE Tensile Bond Strength2,3,4 of Metric Rebar 2,3

ƒ'c = 14 MPa ƒ'c = 28 MPa ƒy = 400 MPa


Embedment Ultimate Allowable Ultimate Allowable Yield Tensile
Rebar Depth Bond Bond Bond Bond Strength Strength
Size (mm) (kN) (kN) (kN) (kN) (kN) (kN)
40 11.1 2.8 16.9 4.2
10M 90 28.0 7.0 36.5 9.1 40 60
180 56.0 14.0 73.4 18.3
65 24.9 6.2 30.7 7.7
15M 130 60.1 15.0 78.7 19.7 80 120
250 120 30.0 157 39.2
90 45.4 11.3 56.9 14.2
20M 180 98.3 24.6 129 32.2 120 180
355 197 49.2 257 64.2
100 62.7 15.7 80.5 20.1
25M 200 145 36.2 189 47.2 200 300
405 289 72.2 377 94.2
125 74.3 18.6 97.0 24.2
30M 250 211 52.8 275 68.8 280 420
455 379 94.8 495 124
180 142 35.5 184 46.0
35M 355 337 84.2 440 110 400 600
510 482 120 629 157
1 Use lesser value of bond strength or rebar’s steel strength for tensile capacity.
2 For anchoring spacing and edge distance guidelines, please refer to the following pages of this HIT-ICE Injection Adhesive Anchor section.

3.2.5

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 217
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Figure 4 - Anchor spacing and edge distance in concrete

Anchor spacing adjustment factors Edge distance adjustment factors

s = Actual spacing c = Actual edge distance


s min = 0.5 h ef cmin = 0.5 h ef
s cr = 1.5 h ef c cr = 1.5 h ef Tension
h ef = Actual embedment = 2.0 h ef for Shear
h ef = Actual embedment

Note: Tables apply for listed


embedment depths. Reduction
factors for other embedment
depths must be calculated
using equations below.

Spacing tension/shear
smin = 0.5 hef scr = 1.5 hef
ƒA = 0.3(s/hef) + 0.55
for scr>s>smin

Edge distance tension


cmin = 0.5 hef ccr = 1.5 hef
ƒRN = 0.4(c/hef) + 0.40
for ccr>c>cmin

Edge distance shear


⊥ toward edge
cmin = 0.5 hef ccr = 2.0 hef
Table 18 - Load adjustment factors for 3/8-in. diameter anchors
ƒRV1 = 0.54(c/hef) – 0.09
for ccr>c>cmin Diameter 3/8-in.
Edge distance shear
Edge distance shear Spacing Edge distance Edge distance shear (II to or away
Adjustment tension/shear tension (⊥ toward edge) from edge)
II to or away from edge
factor ƒA ƒRN ƒRV1 ƒRV2
cmin = 0.5 hef ccr = 2.0 hef
Embedment 1-3/4
ƒRV2 = 0.36(c/hef) + 0.28 3-1/2 5-1/4 1-3/4 3-1/2 5-1/4 1-3/4 3-1/2 5-1/4 1-3/4 3-1/2 5-1/4
depth, in.
for ccr>c>cmin 7/8 0.70 0.60 0.18 0.46
1-1/4 0.76 0.69 0.30 0.54
1-3/4 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46
Spacing (s)/Edge distance (c), in.

2 0.89 0.72 0.86 0.63 0.53 0.22 0.69 0.49


2-5/8 1.00 0.78 0.70 1.00 0.70 0.60 0.72 0.32 0.18 0.82 0.55 0.46
3 0.81 0.72 0.74 0.63 0.84 0.37 0.22 0.90 0.59 0.49
3-1/2 0.85 0.75 0.80 0.67 1.00 0.45 0.27 1.00 0.64 0.52
4 0.89 0.78 0.86 0.70 0.53 0.32 0.69 0.55
4-1/2 0.94 0.81 0.91 0.74 0.60 0.37 0.74 0.59
5-1/4 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64
6-1/2 0.92 0.90 0.91 0.58 0.95 0.73
7 0.95 0.93 1.00 0.63 1.00 0.76
7-7/8 1.00 1.00 0.72 0.82
9 0.84 0.90
10-1/2 1.00 1.00

218 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Table 19 - Load adjustment factors for 1/2-in. diameter anchors Note: Tables apply for listed
embedment depths. Reduction
Diameter 1/2-in. factors for other embedment
Edge distance shear depths must be calculated
Spacing Edge distance Edge distance shear (II to or away using equations below.
Adjustment tension/shear tension (⊥ toward edge) from edge)
factor ƒA ƒRN ƒRV1 ƒRV2
Spacing tension/shear
Embedment 2-1/8
depth, in. 4-1/4 6-3/8 2-1/8 4-1/4 6-3/8 2-1/8 4-1/4 6-3/8 2-1/8 4-1/4 6-3/8 smin = 0.5 hef scr = 1.5 hef
1-1/16 0.70 0.60 0.18 0.46 ƒA = 0.3 (s/hef) + 0.55
1-1/2 0.76 0.68 0.29 0.53 for scr>s>smin
2 0.83 0.78 0.42 0.62
2-1/8 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46
Edge distance tension
2-3/4 0.94 0.74 0.92 0.66 0.61 0.26 0.75 0.51
cmin = 0.5 hef ccr = 1.5 hef
3 0.97 0.76 0.96 0.68 0.67 0.29 0.79 0.53
Spacing (s)/Edge distance (c), in.

3-3/16 1.00 0.78 0.70 1.00 0.70 0.60 0.72 0.32 0.18 0.82 0.55 0.46 ƒRN = 0.4(c/hef) + 0.40
4 0.83 0.74 0.78 0.65 0.93 0.42 0.25 0.96 0.62 0.51 for ccr>c>cmin
4-1/4 0.85 0.75 0.80 0.67 1.00 0.45 0.27 1.00 0.64 0.52
5 0.90 0.79 0.87 0.71 0.55 0.33 0.70 0.56 Edge distance shear
6 0.97 0.83 0.96 0.78 0.67 0.42 0.79 0.62 ⊥ toward edge
6-3/8 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64 cmin = 0.5 hef ccr = 2.0 hef
7 0.88 0.84 0.80 0.50 0.87 0.68 ƒRV1 = 0.54(c/hef) – 0.09
7-1/2 0.90 0.87 0.86 0.55 0.92 0.70 for ccr>c>cmin
8-1/2 0.95 0.93 1.00 0.63 1.00 0.76
9 0.97 0.96 0.67 0.79 Edge distance shear
9-9/16 1.00 1.00 0.72 0.82 II to or away from edge
10 0.76 0.84 cmin = 0.5 hef ccr = 2.0 hef
11 0.84 0.90 ƒRV2 = 0.36(c/hef) + 0.28
12-3/4 1.00 1.00 for ccr>c>cmin

Table 20 - Load adjustment factors for 5/8-in. and 3/4-in. diameter anchors
Diameter 5/8-in. 3/4-in.
Edge distance Edge distance
Edge distance shear Edge distance shear
Spacing Edge distance shear (II to or away Spacing Edge distance shear (II to or away
Adjustment tension/shear tension (⊥ toward edge) from edge) tension/shear tension (⊥ toward edge) from edge)
factor ƒA ƒRN ƒRV1 ƒRV2 ƒA ƒRN ƒRV1 ƒRV2
Embedment 2-1/2
depth, in. 5 7-1/2 2-1/2 5 7-1/2 2-1/2 5 7-1/2 2-1/2 5 7-1/2 3-3/8 6-5/8 10 3-3/8 6-5/8 10 3-3/8 6-5/8 10 3-3/8 6-5/8 10 3.2.5
1-1/4 0.70 0.60 0.18 0.46
1-11/16 0.75 0.67 0.27 0.52 0.70 0.60 0.18 0.46
2 0.79 0.72 0.34 0.57 0.73 0.64 0.23 0.49
2-1/2 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46 0.77 0.70 0.31 0.55
3 0.91 0.73 0.88 0.64 0.56 0.23 0.71 0.50 0.82 0.76 0.39 0.60
3-5/16 0.95 0.75 0.93 0.67 0.63 0.27 0.76 0.52 0.84 0.70 0.79 0.60 0.44 0.18 0.63 0.46
3-3/4 1.00 0.78 0.70 1.00 0.70 0.60 0.72 0.32 0.18 0.82 0.55 0.46 0.88 0.72 0.84 0.63 0.51 0.22 0.68 0.48
4 0.79 0.71 0.72 0.61 0.77 0.34 0.20 0.86 0.57 0.47 0.91 0.73 0.87 0.64 0.55 0.24 0.71 0.50
4-1/2 0.82 0.73 0.76 0.64 0.88 0.40 0.23 0.93 0.60 0.50 0.95 0.75 0.93 0.67 0.63 0.28 0.76 0.52
Spacing (s)/Edge distance (c), in.

5 0.85 0.75 0.80 0.67 1.00 0.45 0.27 1.00 0.64 0.52 0.99 0.78 0.70 0.99 0.70 0.60 0.71 0.32 0.18 0.81 0.55 0.46
5-1/16 0.85 0.75 0.81 0.67 0.46 0.27 0.64 0.52 1.00 0.78 0.70 1.00 0.71 0.60 0.72 0.32 0.18 0.82 0.56 0.46
5-1/2 0.88 0.77 0.84 0.69 0.50 0.31 0.68 0.54 0.80 0.72 0.73 0.62 0.79 0.36 0.21 0.87 0.58 0.48
6 0.91 0.79 0.88 0.72 0.56 0.34 0.71 0.57 0.82 0.73 0.76 0.64 0.87 0.40 0.23 0.92 0.61 0.50
6-3/4 0.96 0.82 0.94 0.76 0.64 0.40 0.77 0.60 0.86 0.75 0.81 0.67 1.00 0.46 0.27 1.00 0.65 0.52
7-1/2 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64 0.89 0.78 0.85 0.70 0.52 0.32 0.69 0.55
8 0.87 0.83 0.77 0.49 0.86 0.66 0.91 0.79 0.88 0.72 0.56 0.34 0.71 0.57
8-1/2 0.89 0.85 0.83 0.52 0.89 0.69 0.93 0.81 0.91 0.74 0.60 0.37 0.74 0.59
9 0.91 0.88 0.88 0.56 0.93 0.71 0.96 0.82 0.94 0.76 0.64 0.40 0.77 0.60
9-15/16 0.95 0.93 0.98 0.63 1.00 0.76 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64
10 0.95 0.93 1.00 0.63 0.76 0.85 0.80 0.73 0.45 0.82 0.64
11-1/4 1.00 1.00 0.72 0.82 0.89 0.85 0.83 0.52 0.89 0.69
12 0.77 0.86 0.91 0.88 0.89 0.56 0.93 0.71
13-1/4 0.86 0.92 0.95 0.93 1.00 0.63 1.00 0.76
14 0.92 0.95 0.97 0.96 0.67 0.78
15 1.00 1.00 1.00 1.00 0.72 0.82
16 0.77 0.86
18 0.88 0.93
20 1.00 1.00

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 219
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System


Table 21 - Load adjustment factors for 7/8-in. diameter anchors Note: Tables apply for listed
embedment depths. Reduction
Diameter 7/8-in. factors for other embedment
Edge distance shear depths must be calculated
Spacing Edge distance Edge distance shear (II to or away using equations below.
Adjustment tension/shear tension (⊥ toward edge) from edge)
factor ƒA ƒRN ƒRV1 ƒRV2
Spacing tension/shear
Embedment 3-3/4 smin = 0.5 hef scr = 1.5 hef
7-1/2 11-1/4 3-3/4 7-1/2 11-1/4 3-3/4 7-1/2 11-1/4 3-3/4 7-1/2 11-1/4
depth, in.
1-7/8 0.70 0.60 0.18 0.46
ƒA = 0.3 (s/hef) + 0.55
2-1/2 0.75 0.67 0.27 0.52 for scr>s>smin
3 0.79 0.72 0.34 0.57
3-3/4 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46
Edge distance tension
4 0.87 0.71 0.83 0.61 0.49 0.20 0.66 0.47
cmin = 0.5 hef ccr = 1.5 hef
4-1/2 0.91 0.73 0.88 0.64 0.56 0.23 0.71 0.50
ƒRN = 0.4(c/hef) + 0.40
5 0.95 0.75 0.93 0.67 0.63 0.27 0.76 0.52
5-5/8 1.00 0.78 0.70 1.00 0.70 0.60 0.72 0.32 0.18 0.82 0.55 0.46 for ccr>c>cmin
Spacing (s)/Edge distance (c), in.

6 0.79 0.71 0.72 0.61 0.77 0.34 0.20 0.86 0.57 0.47
6-1/2 0.81 0.72 0.75 0.63 0.85 0.38 0.22 0.90 0.59 0.49 Edge distance shear
7 0.83 0.74 0.77 0.65 0.92 0.41 0.25 0.95 0.62 0.50 ⊥ toward edge
7-1/2 0.85 0.75 0.80 0.67 1.00 0.45 0.27 1.00 0.64 0.52 cmin = 0.5 hef ccr = 2.0 hef
8 0.87 0.76 0.83 0.68 0.49 0.29 0.66 0.54 ƒRV1 = 0.54(c/hef) – 0.09
8-1/2 0.89 0.78 0.85 0.70 0.52 0.32 0.69 0.55 for ccr>c>cmin
9 0.91 0.79 0.88 0.72 0.56 0.34 0.71 0.57
9-15/16 0.95 0.82 0.93 0.75 0.63 0.39 0.76 0.60 Edge distance shear
10 0.95 0.82 0.93 0.76 0.63 0.39 0.76 0.60 II to or away from edge
11-1/4 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64 cmin = 0.5 hef ccr = 2.0 hef
12 0.87 0.83 0.77 0.49 0.86 0.66 ƒRV2 = 0.36(c/hef) + 0.28
14 0.92 0.90 0.92 0.58 0.95 0.73 for ccr>c>cmin
15 0.95 0.93 1.00 0.63 1.00 0.76
16-7/8 1.00 1.00 0.72 0.82
18 0.77 0.86
20 0.87 0.92
22-1/2 1.00 1.00

Table 22 - Load adjustment factors for 1-in. and 1-1/4-in. diameter anchors
Diameter 1-in. 1-1/4-in.
Edge distance Edge distance
Edge distance shear Edge distance shear
Spacing Edge distance shear (II to or away Spacing Edge distance shear (II to or away
Adjustment tension/shear tension (⊥ toward edge) from edge) tension/shear tension (⊥ toward edge) from edge)
factor ƒA ƒRN ƒRV1 ƒRV2 ƒA ƒRN ƒRV1 ƒRV2
Embedment 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8 6 12 15 6 12 15 6 12 15 6 12 15
depth, in.
2-1/16 0.70 0.60 0.18 0.46
3 0.77 0.69 0.30 0.54 0.70 0.60 0.18 0.46
3-1/2 0.80 0.74 0.37 0.59 0.73 0.63 0.23 0.49
4-1/8 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46 0.76 0.68 0.28 0.53
5 0.91 0.73 0.88 0.64 0.56 0.24 0.72 0.50 0.80 0.73 0.36 0.58
5-1/2 0.95 0.75 0.93 0.67 0.63 0.27 0.76 0.52 0.83 0.77 0.41 0.61
6 0.99 0.77 0.98 0.69 0.70 0.30 0.80 0.54 0.85 0.70 0.80 0.60 0.45 0.18 0.64 0.46
6-3/16 1.00 0.78 0.70 1.00 0.70 0.60 0.72 0.32 0.18 0.82 0.55 0.46 0.86 0.70 0.81 0.61 0.47 0.19 0.65 0.47
7-1/2 0.82 0.73 0.76 0.64 0.89 0.40 0.24 0.93 0.61 0.50 0.93 0.74 0.70 0.90 0.65 0.60 0.59 0.25 0.18 0.73 0.51 0.46
Spacing (s)/Edge distance (c), in.

8-1/4 0.85 0.75 0.80 0.67 1.00 0.45 0.27 1.00 0.64 0.52 0.96 0.76 0.72 0.95 0.68 0.62 0.65 0.28 0.21 0.78 0.53 0.48
9 0.88 0.77 0.84 0.69 0.50 0.30 0.67 0.54 1.00 0.78 0.73 1.00 0.70 0.64 0.72 0.32 0.23 0.82 0.55 0.50
9-1/2 0.90 0.78 0.86 0.71 0.53 0.32 0.69 0.56 0.79 0.74 0.72 0.65 0.77 0.34 0.25 0.85 0.57 0.51
10 0.91 0.79 0.88 0.72 0.56 0.35 0.72 0.57 0.80 0.75 0.73 0.67 0.81 0.36 0.27 0.88 0.58 0.52
10-1/2 0.93 0.80 0.91 0.74 0.60 0.37 0.74 0.59 0.81 0.76 0.75 0.68 0.86 0.38 0.29 0.91 0.60 0.53
12 0.99 0.84 0.98 0.79 0.70 0.43 0.80 0.63 0.85 0.79 0.80 0.72 1.00 0.45 0.34 1.00 0.64 0.57
12-3/8 1.00 0.85 1.00 0.80 0.72 0.45 0.82 0.64 0.86 0.80 0.81 0.73 0.47 0.36 0.65 0.58
14 0.89 0.85 0.83 0.52 0.89 0.69 0.90 0.83 0.87 0.77 0.54 0.41 0.70 0.62
16-1/2 0.95 0.93 1.00 0.63 1.00 0.76 0.96 0.88 0.95 0.84 0.65 0.50 0.78 0.68
18 0.99 0.98 0.70 0.80 1.00 0.91 1.00 0.88 0.72 0.56 0.82 0.71
18-9/16 1.00 1.00 0.72 0.82 0.92 0.90 0.75 0.58 0.84 0.73
20 0.78 0.86 0.95 0.93 0.81 0.63 0.88 0.76
22-1/2 0.89 0.93 1.00 1.00 0.92 0.72 0.96 0.82
24 0.96 0.98 1.00 0.77 1.00 0.86
24-3/4 1.00 1.00 0.80 0.87
26 0.85 0.90
28 0.92 0.95
30 1.00 1.00

220 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17
Adhesive Anchoring Systems

HIT-ICE Adhesive Anchoring System 3.2.5


Figure 5 - Influence of temperature on bond strength1,2 Table 23 - Open gel time1,2
Base material temperature
HIT-ICE
°F °C
–10 –23 1.5 h
Allowable bond strength
% of load at 70°F

0 –18 1.5 h
23 –5 40 min
32 0 26 min
41 5 11 min
68 20 4 min
86 30 1.5 min

Table 24 - Full cure time1,2


Base material temperature °F
Base material temperature
HIT-ICE
°F °C
1 Test procedure involves the concrete being held at the elevated
–10 –23 36 h
temperature for 24 hours them removing it from the controlled en-
vironment and testing to failure. 0 –18 24 h
2 Long term creep test in accordance with ICC-ES Acceptance Cri- 23 –5 6h
teria AC58. 32 0 4h
41 5 2h
68 20 1h
86 30 30 min
1 Product temperatures must be maintained above
0°F (–18°C) prior to installation.
2 Gel times and full cure times are approximate.

3.2.5.4 Installation instructions


Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online
at www.hilti.com. Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper
installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applica-
tions and conditions not addressed in the IFU. 3.2.5

HIT-ICE volume
Table 25 - Threaded rod installation Table 26 - Rebar installation1 Table 27 - CA rebar installation c
Nominal Adhesive volume Adhesive Adhesive volume
anchor Drill bit required volume required
diameter diameter per Inch of required Bar Drill Bit1 per Inch of
in. in. embedment in 3 Nominal bit1 per Inch of Diameter Diameter embedment (in. 3)
1/4 5/16 0.055 Rebar diameter embedment 10M 14 mm 0.101
size in. in 3
3/8 7/16 0.095 15M 3/4” 0.176
#3 1/2 0.110
1/2 9/16 0.133 20M 24 mm 0.268
#4 5/8 0.146
5/8 11/16 0.184 25M 1-1/8” 0.309
#5 3/4 0.176
3/4 13/16 0.232 30M 37 mm 0.644
#6 7/8 0.218
7/8 24mm 0.272 35M 1-9/16” 0.480
#7 1 0.252
1 1-1/16 0.366
#8 1-1/8 0.299
1-1/4 1-1/2 0.918
#9 1-3/8 0.601
Example:
#10 1-1/2 0.659
A HIT-ICE cartridge contains a useable #11 1-3/4 1.037
volume of 18 in3. So, for a 5/8-in. diameter
1 Rebar diameter may vary. Use smallest drill bit
rod with an embedment of 10 inches:
which will accommodate rebar.
10 in. x 0.184 in3 /in. =1.84 in3/fastening
18 in3/cartridge ÷ 1.84 in3/fastening = 10
fastenings/cartridge

Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17 221
Adhesive Anchoring Systems

3.2.5 HIT-ICE Adhesive Anchoring System

3.2.5.5 Ordering information1


Description Contents
HIT-ICE Cartridge 10 oz (297 ml) 24 Cartridges, 24 Mixers HIT-ICE Cartridge

Description Notes Qty/Pkg


MD 1000
MD 1000 Dispenser For use with HIT-ICE cartridges 1 Dispenser

Description Notes Qty/Pkg


HIT-ICE Mixer
HIT-M2 Mixer for HIT-ICE only For use with HIT-ICE cartridges 1

HIT Filler Tube

For ordering information on anchor rods and inserts, dispensers, hole cleaning equipment and other accessories, see section 3.2.9.

HIT-ICE Mixer HIT-ICE Cartridge HIT-ICE Dispenser

222 Hilti, Inc. (US) 1-800-879-8000 | www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I Anchor Fastening Technical Guide Ed. 17