You are on page 1of 38

Duetto MT

Dermatology Platform
755 and 1064 nm, now together.
R eliability and innovation
• Alexandrite 755 nm Long Pulse, up to 16 mm spot size and
2Hz of repetition rate

• Nd:YAG 1064 nm Long Pulse, up to 12 mm spot size and


2Hz of repetition rate

• Nd:YAG 1064 nm Short Pulse, Up to 6 mm spot size and


7Hz of repetition rate

• MT modality for SIMULTANEOUS or SEQUENTIAL


emission of 755 and 1064 nm up to 16 mm spot size

• TWAIN IPL source with cut-off filters at 400, 550, 570, 590,
625, 650 nm. Fluence up to 30J/Cm2 and 0.5 Hz of repetition
rate

• TWAIN Er:YAG 2940 nm fractional handpiece


C o m b in e d s y s t e m , t o p p e r f o r m a n c e s ,
f a s t r e t u r n o f in v e s t m e n t
Quanta System S.p.A.
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Clinic al advantages of
Duetto MT

• Long Pulse Alexandrite 755 nm. The gold standard for HAIR
REMOVAL on light skin types
• Long pulse Nd:YAG 1064 nm for HAIR REMOVAL on skin
type VI
• Long pulse Nd:YAG 1064 nm for VASCULAR TREATMENTS

• MT modality for HAIR REMOVAL on dark and tanned


skins allowing virtually no seasonal stops of treatments

• MT modality for enhanced SKIN REJUVENATION treatments

• MT modality for enhanced VASCULAR treatments

• Twain IPL and 2940 Extensions for MAXIMUM FLEXIBILITY of


use

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Tec hnologic al advantages
of Duetto MT

• MT (Mixed Technology) modality for simultaneous or


sequential emission of 755 and 1064 nm lasers
• Real time monitoring and following of the pulse energy of
the laser
• Very low energy fluctuation,
fluctuation less than 5%
• Longer flash lamps life time

• No warm up time

• Automatic recognition of the spot size

• TWAIN connector for further upgrades

• IPL calibration port on board

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Tec hnologic al advantages
of Duetto MT

power power

Standard emission

time time
Emission of Alex 755 nm only Emission of Nd:Yag 1064 nm only

power power

MT modality

time time

SEQUENTIAL emission of 755 nm and 1064 nm SIMULTANEOUS emission of 755 nm and 1064 nm
with independent pulse width and with same pulse width
variable delay between the two pulses (from 0 to 50 ms)

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Duetto MT Graphic User Interface

• Color Touch Screen with proprietary OS, very stable operation and faster
Bootstrap sequence. Just 1 minute to be ready
• Intuitive and user-friendly User Interface
• Auto recognizing of the installed handpiece
• Very fast switching trough
the different pulse modalities
• Easy software upgrade
(through serial port rs232)

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
D u e tto MT
Ac c essories

Duetto MT, trough the Universal Twain Connector, can be upgraded at any time with a powerful
Fractional Er:YAG 2940 nm for Skin Rejuvenation that has also standard ablative
capability and with the TWAIN IPL handpieces for Hair Removal, Vascular and Active
Acne treatments.
These options maximize the extension of the application fields at the widest range available
today.
-

The Fractional
and standard
The Universal
TWAIN Er:YAG
TWAIN Connector
2940nm handpiece
The TWAIN IPL

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Indic ations

• Hair Removal
• Vascular lesions removal
• Pigmented lesions removal
• Benign skin solid lesions
• Scar revision
• Skin Rejuvenation

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Indic ations

SELECTIVE
PHOTOTHERMOLYSIS
(RR Anderson, JA Parrish, 1983)

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Selective Photothermoly sis

Selective aggression of the target without damage of adjacent


tissues

Parameters:

• Wavelength
• Fluence
• Pulse Width: ≤ TRT

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Selective Photothermoly sis

Absorption
1064 nm is an optimal wavelength for the treatment of superficial blood vessels.
755 nm for hair removal up to Skin Type IV, 1064 nm also for darker skin 1064 nm, due to
water absorption is ideal also for skin tightening.
The epidermal melanin absorption has to been taken into consideration to avoid side effects,
Duetto MT modality improves flexibility and safety

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Selective Photothermoly sis

Different Melanin absorption to target safely every skin types

Reduced water absorption on dark skin types (with Mixed Technology)


to reduce the treatment discomfort

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Selective Photothermoly sis

Penetration

Longer wavelengths as preferable for deeper or


larger vessels, because of their greater penetration
into tissue and because

The relative low melanin absorption may allow more


safe heating of the full thickness of the vessel with
less risks of epidermal ipo-pigmentation.

For small telangiectasia - such as those occurring


commonly on the face and for PWS, lasers emitting
wavelengths at or near 532nm are more suitable,

For leg veins treatments the 1064 nm wavelength of


is preferable. Approx. wavelenghts
penetration in the skin

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Selective Photothermoly sis

Laser pulse duration – TRT of targets

Exposure times for blood vessels should be shorter than their thermal relaxation times
Complete heating is achieved without risks of thermal damage of the surrounding tissues
(Selective Photothermolysis).
Exposure times range from 10 to 80 milliseconds for telangiectasia, following the vessel’s
diameter.
The power output of the laser must be high enough to permit adequate energy density
for vessel coagulation within this time (Energy = Power x Time).
Performing Hair Removal procedures the exposure time depends by the thickness of the
hair

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hair removal
The melanin in the stem absorbs the laser
radiation producing heat.
The adjacent cells, responsible of the hair’s
genesis and growth, are permanently
damaged through thermal management.
The required heat must be correctly
administered, in order to selectively
damage the Bulge and the Papilla of the
Hair Bulb and not harm the skin.
The variables:
• Skin type
• Tanning
• Body area
• Color of the hair
• Thickness of the hair
• Follicles density
Quanta System S.p.A.
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Fitzpatrick’s Skin Types

Skin Working Color


Type Classification
I Always burn easily White
Never tans, extremely
Sensitive to Sun

II Always burns easily, White


Tans minimally, very
Sensitive to the sun

III Sometimes burns, White/Asian


Tans gradually to
Light brown, sun
Sensitive skin

IV Burns minimally Moderate brown


Always tans to
Moderate brown,
Minimally sun
Sensitive

V Very rarely burns, tans Dark Brown


Well, sun insensitive
Skin

VI Never burns, deep Black


Pigmented, sun
Insensitive skin
Quanta System S.p.A.
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hair removal proc edure through
I ntense Pulsed Lig ht (PL)

More than one treatment is


necessary to get the desired
reduction.
Only during the growth stage
(Anagen) the hair is in contact
with the hair papilla, the
section of the bulb responsible
of the growth. Consequently,
the bulb can be permanently
damaged only during that
phase.
A different number of
treatments have to be
performed at varying intervals,
according to the targeted
anatomical district.

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Two wavelengths for Hair removal

According to the skin colour (and


therefore to the different degrees of
melanin content) it is recommended to
Black hair
use different wavelengths. In particular:

- for blonde and red haired subjects, the


shorter wavelength of Alex 755 nm is
recommended;
- for brown and black haired subjects, it
Fair hair is recommended the use of Alex 755
alone or the Mixed 755+1064 nm
Modality

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
The Mixed Tec hnology
It can delivers 755 nm and 1064 nm in one shot to optimize
the treatment efficiency:
755 nm and 1064 nm lasers work together to completely denature the hair follicles in all
the skin conditions.
The result is the need of a less fluence compared with Alex or Nd:YAG alone, ideal to
perform treatments with more results and more comfort on dark skin types

Alex 755 nm
Nd:YAG 1064 nm
The synergy of the two
wavelengths are able to
efficiently destroy also the hair
follicle of dark skin types with
improved safety and less pain if
compared with diode or just
Nd:YAG lasers

1064 nm is also emitted


at about 50% of the 755 nm is more absorbed by
standard fluence melanin and in combined
together with the Alex emission with 1064 nm the
755 nm fluence to be delivered is the
half of the standard dose

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Duetto MT, utterly effective with
no side effects

• Alex 755 nm, after one session 20-58% hair reduction (Finkel et al, 1997)

• Alex 755 nm, after 3-5 treatments hair reduction up to 80-95%

• Mixed Technology modality have the same effectiveness of the Alex alone on dark
skin types with better safety

• Mixed Technology modality has lower incidence of side affects: no hypo, hyper-
pigmentations and blisters with appropriate cooling system and parameters

• 100 times faster than electrolysis and have twice better clearance rate

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
The Mixed Tec hnology
ap p lied to V asc ular Lesions

2nd Pulse 1st Pulse


Nd:YAG 1064 nm Alex 755 nm

Hemoglobin absorbs 755 nm Methemoglobin absorbs the


and became methemoglobin 1064 nm 3 times more
efficiently then hemoglobin

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Duetto MT, better balance of
safety and effectiveness for
vascular lesions

• The combination in sequence of Alex 755 nm and Nd:YAG 1064 nm is ideal for leg
veins treatments

• Less painful leg veins treatment by using 755 nm due to convert oxyhemoglobin to
methemoglobin (with 3 times more absorption by1064 nm) to deliver reduced
fluences

• Mixed

• Mixed Technology modality has lower incidence of side affects: no hypo, hyper-
pigmentations and blisters with appropriate cooling system and parameters

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Clinical Results

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
The Nd :YAG Long p ulse laser
effect on blood vessels

Adjustable pulse duration spares normal capillaries, avoiding purpura.


purpura.

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Leg Telang iec tasia

WAVELENGTHS: 755 nm + 1064 nm


SKIN TYPE 2
SPOT SIZE: 4 mm
EV. FLUENCE: 45 J/Cm2 @ 755 nm + 130 J/Cm2 @ 1064 nm (with sapphire window)
PULSE WIDTH: 15 ms @ 755 nm + 5 ms delay + 15 ms @ 1064 nm
SESSIONS: 1
FOLLOW UP: 2 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Leg Telang iec tasia ( p r e v io u s c a s e )

WAVELENGTHS: 755 nm + 1064 nm


SKIN TYPE 2
SPOT SIZE: 4 mm
EV. FLUENCE: 45 J/Cm2 @ 755 nm + 130 J/Cm2 @ 1064 nm (with sapphire window)
PULSE WIDTH: 15 ms @ 755 nm + 5 ms delay + 15 ms @ 1064 nm
SESSIONS: 1
FOLLOW UP: 2 months
Quanta System S.p.A.
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Leg Telang iec tasia

5 minutes post

WAVELENGTH: 1064 nm
SKIN TYPE 2
SPOT SIZE: 6 mm
EV. FLUENCE: 130 J/Cm2 (with sapphire window)
PULSE WIDTH: 20 ms
SESSIONS: 1
FOLLOW UP: 5 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Leg telang iec tasia

SYSTEM: 1064 nm
SKIN TYPE 2
SPOT SIZE: 4 mm
EV. FLUENCE: 140 J/Cm2 @ 1064 nm (no sapphire window)
FREQUENCY: 1 Hz
SESSIONS: 2
FOLLOW UP: 6 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Face telangiectasia

WAVELENGTH: 1064 nm
SKIN TYPE 2
SPOT SIZE: 3 mm
EV. FLUENCE: 150 J/Cm2 @ 1064 nm (no sapphire window)
FREQUENCY: 1 Hz
SESSIONS: 2
FOLLOW UP: 4 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Face telangiectasia

WAVELENGTH: 1064 nm
SKIN TYPE 2
SPOT SIZE: 3 mm
EV. FLUENCE: 130 J/Cm2 @ 1064 nm (no sapphire window)
FREQUENCY: 1 Hz
SESSIONS: 1
FOLLOW UP: Immediate post

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Spider angioma

WAVELENGTH: 1064 nm
SKIN TYPE 2
SPOT SIZE: 4 mm
EV. FLUENCE: 130 J/Cm2 @ 1064 nm (no sapphire window)
FREQUENCY: 1 Hz
SESSIONS: 2

FOLLOW UP: 2 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Vascular lesions

SYSTEM: Nd:YAG LASER 1064 nm


SKIN TYPE 3
SPOT SIZE: 6 mm (no sapphire window)
EV. FLUENCE: 90 J/Cm2
FREQUENCY: 1 Hz
SESSIONS: 1
FOLLOW UP: 1 month

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hemangioma

SYSTEM: Nd:YAG LASER 1064 nm


SKIN TYPE 2
AREA: cheek and neck
SPOT SIZE: 6 mm
EV. FLUENCE: 40 J/Cm2 @ 1064 nm (test)
FREQUENCY: 1 Hz
SESSIONS: 1
FOLLOW UP: 1 month

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hair removal

SYSTEM: Long Pulse 755 nm


SKIN TYPE 3
AREA: AXILLA
SPOT SIZE: 14 mm
EV. FLUENCE: 20 J/Cm2
FREQUENCY: 1.5 Hz
SESSIONS: 4
FOLLOW UP: 6 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hair removal

SYSTEM: Long Pulse 1064 nm


SKIN TYPE 3
AREA: Chest
SPOT SIZE: 10 mm
EV. FLUENCE: 55 J/Cm2
FREQUENCY: 1.5 Hz
SESSIONS: 5
FOLLOW UP: 6 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Hair removal

755 nm 755 + 1064 nm 755 nm 755 + 1064 nm

SYSTEM: Duetto MT; LP 755 nm (left side),


755+1064 (right side)
SKIN TYPE 3
AREA: Back
SPOT SIZE: 14 mm
EV. FLUENCE: 18 J/Cm2 (left side), 11+20 J/Cm2 (right side)
FREQUENCY: 1.5 Hz
SESSIONS: 2
FOLLOW UP: 3 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Skin rejuvenation

SYSTEM: Short Pulse 1064 nm


SKIN TYPE 5
AREA: FACE
SPOT SIZE: 6 mm
EV. FLUENCE: 16 J/Cm2
FREQUENCY: 7 Hz
SESSIONS: 4
FOLLOW UP: 6 months

Quanta System S.p.A.


Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39-0331.376797 - Fax +39-0331.367815
Web: www.quantasystem.com e-mail: quanta@quantasystem.com
Thank you!

You might also like