You are on page 1of 1

dP

Date 09/02/2012
File new.dvl
Owner
Project Name
Pipe Name

LIQUID DATA
flow rate 200000 [liter/hr]
density 1000 [kg/m3]
dynamic viscosity 1 [cP]

PIPE DATA
inner diameter 219 [mm]
surface roughness 0,5 [mm]
total pipe length 150 [m]
elevation 10 [m]
pressure loss extra equipment 2 [bar]

APPENDAGES DATA
== Bends ==
180 bend, R=5D 0
90 bend, R=5D 0
90 bend (square , R=1.5D) 4
45 bend(square , R=1.5D) 0
Tee (flow straight through) 0
Tee (flow through side outlet) 0
== Valves ==
Gate valve open 0
1/4-closed 0
1/2-closed 0
3/4-closed 0
Membrane valve 0
Ball valve (spherical plug valve) 0
Needle valve 0
Butterfly valve (larger then 6 inch) 2
Globe valve 0
Nozzle (suction nozzle on vessel) 0
Check valve (in-line ball type) 0
Check valve (swing type) 0
Filter (Y-type and bucket type) 0
bends and elbows 80 [l/d]
valves 40 [l/d]
fittings and appendages 26,28 [m]

RESULTS
msg ..............
Reynolds number 322993,3 [-]
average velocity of liquid 1,47 [m/s]
friction factor 0,0247 [-]
relative roughness surface 0,0023 [-]
friction of pipe 16,9178 [-]
pipe area 37668,4813 [mm]
pipe volume 5650,27 [liter]
friction of appendages 2,9640 [-]
average residence time 101,70 [sec]
pressure drop pipe 1,1972 [bar]
power loss 17762,4 [Watt]

TOTAL PRESSURE DROP


==> 3,1972 [bar]
==> 319723 [Pa]