Barrels of slug required for a desired length of dry pipe

Desired length of dry pipe (ft) 400 ft


Drill pipe capacity (bbl/ft) 0.015 bbl/ft
Current MW (PPG) 11.5 ppg
Slug Weight (PPG) 12.5 ppg

Hydrostatic pressure required to give desired drop inside drill pipe 239.2 psi
Difference in pressure gradient bw slug and current MW 0.052 psi/ft
Length of slug in drill pipe (ft) 4600 ft
Slug Volume 69.00 bbl