You are on page 1of 4

BOP stack volumes

BOP Stack operating volumes


BOP Type Hydril Operating pressure = 10000 psi

Operating Volumes No of requirements Required Volumes


Function
Open Close Close Open Close Open
Annular preventer 1 44.00 gall 44.00 gall 2 1 88.00 gall 44.00 gall
Annular preventer 2 44.00 gall 44.00 gall 2 1 88.00 gall 44.00 gall
Pipe ram 1 17.10 gall 15.60 gall 2 1 34.20 gall 15.60 gall
Pipe ram 2 17.10 gall 15.60 gall 2 1 34.20 gall 15.60 gall
Pipe ram 3 17.10 gall 15.60 gall 2 1 34.20 gall 15.60 gall
Pipe ram 4 17.10 gall 15.60 gall 0 0 0.00 gall 0.00 gall
Bind shear 23.40 gall 21.80 gall 2 1 46.80 gall 21.80 gall
Casing shear 23.40 gall 21.80 gall 0 0 0.00 gall 0.00 gall
Failsafes 8 0.60 gall 0.60 gall 1 2 4.80 gall 1.20 gall

Total = 486.80 gallons

Kingdom Drilling Services Ltd Confidential www.kingdomdrilling.co.uk Page 1


Subsea accumulators
Operating depth 1500 ft

Sea water gradient 0.445 psi/ft

Precharge increase required 668 psi

Nitrogen Precharge pressure 1000 psi


P1
Nitrogen Precharge pressure required 1668 psi

Minimum operating pressure 1200 psi


P2
Minimum operating pressure required 1868 psi

Maximum operating pressure 3000 psi


P3
Maximum operating pressure required 3668 psi
V1 Bladder volume at pre-charge 10 gall
V2 Bladder volume at min. operating pressure 8.93 gall
V3 Bladder volume at max. operating pressure. 4.55 gall

Useable volume I.e. (V3-V2) = 4.38 gall

No of bottles required = 107

Kingdom Drilling Services Ltd Confidential www.kingdomdrilling.co.uk Page 2


Surface accumulators
P1 Nitrogen Precharge pressure 1000 psi
P2 Minimum operating pressure 1200 psi
P3 Maximum operating pressure 3000 psi
V1 Bladder volume at pre-charge 10 gall
V2 Bladder volume at min. operating pressure 8.33 gall
V3 Bladder volume at max. operating pressure 3.33 gall

Vu Useable volume I.e. (V3-V2) = 5.00 gall

You might also like