TL-D Standard Colours


TL-D 36W/54-765 1SL/25
TL-D Standard Colors lamps (tube diameter of 26 mm) create atmospheres from warm
white to cool daylight. Lamps with moderate efficacy and color rendering.

Product data

General Information Controls and Dimming


Cap-Base G13 [ Medium Bi-Pin Fluorescent] Dimmable Yes

Life to 10% Failures (Nom) 10000 h

Life to 50% Failures (Nom) 13000 h Approval and Application


Energy Efficiency Label (EEL) A

Light Technical Mercury (Hg) Content (Nom) 8.0 mg

Color Code 54-765 Energy Consumption kWh/1000 h 43 kWh

Luminous Flux (Nom) 2500 lm

Color Designation Cool Daylight Product Data


Lumen Maintenance 10000 h (Nom) 75 % Full product code 692341077032200

Lumen Maintenance 2000 h (Nom) 90 % Order product name TL-D 36W/54-765 1SL/25

Lumen Maintenance 5000 h (Nom) 80 % EAN/UPC - Product 6923410770322

Correlated Color Temperature (Nom) 6200 K Order code 928048505453

Color Rendering Index (Nom) 72 Numerator - Quantity Per Pack 1

Numerator - Packs per outer box 25

Operating and Electrical Material Nr. (12NC) 928048505453

Power (Rated) (Nom) 36.0 W Net Weight (Piece) 0.140 kg

Lamp Current (Nom) 0.440 A ILCOS Code FD-36/62/2A-E-G13

Voltage (Nom) 103 V

Warnings and Safety


• A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a
vacuum cleaner.

Datasheet, 2018, August 23 data subject to change


TL-D Standard Colours

Dimensional drawing

Product D (max) A (max) B (max) B (min) C (max)

TL-D 36W/54-765 1SL/25 28 mm 1199.4 mm 1206.5 mm 1204.1 mm 1213.6 mm

D
A
B
C
TL-D 36W/54-765

Photometric data
µW per 5 nm per lm

µ W per 5 nm per lm
500
500

400
400

300
300

200 200

100 100

300 400 500 600 700 l nm


300 400 500 600 700 λ nm

Lightcolor /54-765 Lightcolor /54-765

Lifetime

100 100
Lamp survival (%)

Lamp survival (%)

90 90
ElectroMagnetic ElectroMagnetic
80 80

70 70

60 60

50 50
0 5000 10000 15000 20000 0 5000 10000 15000 20000
Operating time (hours) Operating time (hours)

TL-D Standard Colours Life Expectancy 3 h cycle TL-D Standard Colours Life Expectancy 12 h cycle

Datasheet, 2018, August 23 2 data subject to change


TL-D Standard Colours

Lifetime

100
Lamp luminous flux (%)

90

80

70

60

50
0 5000 10000 15000 20000
Operating time (hours)

TL-D Standard Colours Lumen Maintenance 3 h + 12 h cycle

© 2018 Philips Lighting Holding B.V. All rights reserved. Philips Lighting reserves the right to make changes in specifications

and/or to discontinue any product at any timewithout notice or obligation and will not be liable for any consequences resulting www.lighting.philips.com

from the use of this publication. 2018, August 23 - data subject to change