Dissolved oxygen content of the water of fish ponds is one of the most important parameters
of water quality, as the oxygen is a vital condition for all the organisms living in the water and
having an aerobic type of respiration. The solubility of oxygen is influenced by several factors
(e.g. air pressure, hydrostatical pressure, salt content), but in pond fish farms it is generally
enough to consider only water temperature.
Diurnal changes of the dissolved oxygen content of pond water during a period of time tc c - tc
can be expressed by the following equation:
O2c c - O2c = P - R - Y ± A
where
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 2 of 38
Since the most significant positive value (P) of the above formula is dependent on light
conditions (the photosynthesis can take place only by utilization of solar energy), the
dissolved oxygen content of the fish pond varies over a period of 24 hours.
Figure 1 shows a typical daily change of oxygen concentration of a fish pond. The
photosynthesis starts gradually from the early morning hours while the dissolved oxygen
content of the water is increasing. The maximum value, in several cases much higher than
the saturation level, can be observed early in the afternoon.
From the late afternoon hours photosynthesis is rapidly decreasing and is stopped after dark.
The dissolved oxygen content of the water is also decreasing during this period, the
minimum value occurring during the summer months.
Those organisms which live in the water of a fish pond and have chlorophyll, produce
carbohydrates from the carbon dioxide and the water in the process of photosynthesis by
utilization of solar energy, while oxygen is produced as a by-product of the process. In
deeper water ponds the biggest part of the oxygen produced comes from the phytoplankton,
but in shallow ponds the macrovegetation, the algae and the benthic algae have a
dominating role. Among the factors influencing production of fish ponds water temperature
and illumination are the most important.
Table 1 The oxygen saturation concentrations in the water as a function of water temperature
at 760 torr
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 3 of 38
Figure 1. Diurnal change of the dissolved oxygen concentration in intensive fish pond
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 4 of 38
The relationship between illumination and oxygen production can be seen in Figure 2. The
intensity of light affects significantly the oxygen budget of pond water. If the intensity of solar
radiation is high during a day without overcast, a quantity of dissolved oxygen is produced.
This covers the oxygen demand of respiration during the night. In the cases when solar
radiation is less intensive because of cloud cover, the oxygen production and thus the
oxygen reserve for the night is less. During the night the respiration of organisms in the water
does not decrease - or at least not in the same rate - and the oxygen reserve of the pond
water can be exhausted. Thus the concentration of dissolved oxygen can decrease below
the lethal level for fish.
This situation can be extremely dangerous at the end of a growing season in August, when
the length of the days is shorter (Figure 3), the quantity of daytime production is less, and at
the same time the biomass is the highest.
Studying the values of oxygen saturation at 2 p.m. and 5 a.m. throughout the growing
season, it has been found that in the case when the dissolved oxygen content at 2 p.m. did
not reach 10-12 mg/l, the oxygen content decreased to a dangerous level during the hours of
sunrise, and depending on the length of the oxygen shortage period, it caused fish kills
(Figure 4).
If the light conditions are not favourable a very dangerous situation can develop (short day,
cloudy sky).
After over-production of phytoplankton, production can be decreased not only because of the
self-screening effect but by the disruption of nutrient equilibrium. In critical cases heavy
losses of plankton can take place.
The relationship between oxygen production and water temperature in an intensive carp
production pond is shown on Figure 5. Although the oxygen production of pond water will be
higher and higher due to the increase of temperature, a critical situation occurs in the case of
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 5 of 38
high water temperatures because the rate of oxygen consumption exceeds the rate of
production.
1.2.2 Oxygen consumption by pond water
In another case in a manured but empty fishpond the mass of phytoplankton decreased
nearly to zero due to over-production of zooplankton. In this case the zooplankton was the
main consumer of oxygen. In the case of a stocked fish pond on the other hand, the mass of
zooplankton decreased to such a minimum level due to the consumption by fish that even
the chemical destruction of the remaining zooplankton did not make any demonstrable
change in oxygen consumption of the pond water.
Fish pond water is a complicated biological complex, thus its oxygen consumption is different
from pond to pond under different conditions.
In an intensive channel catfish production pond a correlation has been found between
oxygen consumption of pond water and water temperature as shown in Figure 6.
Determination of primary production and of oxygen consumption of pond water has been
carried out by the Fish Culture Research Institute. Based on a mathematical analysis of daily
oxygen curves, it was found that the intensity of respiration in the fish ponds studied has
shown a significant daily rhythm, with an afternoon maximum, and that it has been in direct
proportion to oxygen concentration (Figure 7).
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 6 of 38
Figure 4. The oxygen concentration in the surface of a fish pond at 0500 and 1400
hours
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 7 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 8 of 38
Figure 6. The oxygen consumption of the water of a fish pond as a function of water
temperature
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 9 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 10 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 11 of 38
Figure 10. The oxygen consumption of different fish species as a function of the
dissolved oxygen content of the water (in closed system)
1.2.3 Oxygen consumption by the pond bottom
Oxygen consumption by the pond bottom is dependent on the oxygen requirement for
decomposition of organic material accumulated on the pond bottom and for vital functions of
benthos. Oxygen fixation taking place in the water mud interfacial area can also not be
neglected. The dissolved oxygen content of the water layer directly in contact with the mud is
much lower than that of the upper layers of water.
According to some studies the 24 hour-long oxygen consumption of the pond bottom is 1-3
grams per m2. Calculating with 1 m water depth, the 24 hour-long oxygen consumption of the
pond bottom changes between 1 and 3 mg/l.
1.2.4 Oxygen consumption by fish
The different fish species have become adapted to different living conditions during their
evolution. Generally all those fish species which live in fast flowing and oxygen rich streams
(e.g. Salmonids) need high quantities of oxygen, and only a small decrease of dissolved
oxygen can cause losses. At the same time the species which became accustomed to slow
motion of the water or stagnant water (e.g. several Cyprinids) need less oxygen and are able
to tolerate short periods of oxygen deficiency.
Some fish species are also known, mainly in the tropics, to utilize the oxygen of the
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 12 of 38
Oxygen consumption by fish is generally given in mg/body weight and kg/hour. Standard
oxygen consumption means the quantity of oxygen consumed by the fish without swimming
and feeding (quantity of oxygen necessary for subsistence). Standard oxygen consumption
is not dependent on oxygen saturation of the water but it is significantly influenced by water
temperature.
Figure 8 shows standard oxygen consumption of some fish species as a function of water
temperature on the basis of the data of several authors. In the practice of fish culture the
active oxygen consumption (the oxygen consumed by swimming and feeding fish) can be
used.
Active oxygen consumption by fish has been analyzed very rarely till now because of the
technical difficulties of measuring, and available data can not be compared because of
inaccurate or imperfect description of the circumstances of measurement.
Table 2, showing oxygen consumption of different fish species, gives the size of fish and an
idea of the motion where they have been cited. From Table 3 it is obvious that oxygen
consumption by fish can significantly change at a given water temperature depending on the
activity of fish. Table 2 shows that in identical conditions oxygen consumption by smaller size
fish is higher.
Figure 9 shows changes of oxygen consumption by common carp, grass carp, silver and
bighead carp against body weight.
Active oxygen consumption by fish has a strict connection with oxygen saturation of the
water. Figure 10 shows the correlation between oxygen saturation and oxygen consumption
by fish, for seven fish species. Some scientists are of the opinion that fish are able to sense a
decrease of dissolved oxygen content of the water before it causes troubles in their
respiration and therefore they look for water of higher oxygen content. If this is not successful
and the dissolved oxygen content of the water decreases further, the respiratory motion of
the fish is increased as long as the oxygen supply to respiratory muscles permits. This
reaches a limit when further acceleration is hindered by lack of oxygen. Fish are tolerant till
this level. If the dissolved oxygen content of the water decreases further, the pulsation of the
heart slows down and the fish dies after a time depending on the resistance characteristic of
the species. Lethal oxygen concentration is the dissolved oxygen content that can not be
tolerated by the given fish species for a given period of time.
Table 2 The oxygen consumption of several fish species (Source: J. Oláh, Manuscript, Fish
Culture Research Institute, 1979)
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 13 of 38
Table 3 The oxygen consumption (ing/kg/hour) of 100 g rainbow trout (Salmo gairdneri) as a
function of water temperature and fish activity (the dissolved oxygen concentration in the
water is 80-90%)
Figure 11 shows that there were no significant losses of fish in an intensively manured fish
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 14 of 38
pond with 0.3 mg/l dissolved oxygen content if the period of oxygen shortage was brief. But
more than ten hours of oxygen shortage caused serious losses of fish.
On the basis of investigations on intensive pond culture of common carp in Central Europe,
the probability of oxygen deficiency (less than 1 mg/l dissolved oxygen) is nearly continuous
from the beginning of July till the beginning of September, but losses caused by oxygen
deficiency occur generally in August. This can be explained by the fact that in July the period
of oxygen deficiency is only 1-2 hours but in August sometimes twelve hours of oxygen
deficiency can occur.
In the practice of pond fish farming oxygen deficiency has been regarded as dangerous
mainly because of mass losses of fish. But recent investigations have shown that decreased
oxygen saturation can have serious effects on the economy of a fish farm as well.
Increase of toxic effect of different toxic materials can not be neglected in water bodies with
low oxygen supply. The low oxygen content disadvantageously influences both the food
intake and the utilization of food. Investigations have shown that lower than 25% oxygen
saturation occurring before sunrise has a disadvantageous effect on fish-growing.
Keeping the dissolved oxygen content of the pond water nearly at the saturation level makes
it possible not only to avoid mass losses of fish but ensures better conversion rates and
higher yields in intensive culture.
1.2.5 Natural diffusion caused by wind action
Diffusion is caused by partial differential pressure of oxygen in the air and in the water.
As the oxygen content of the air is considered to be constant, the rate of diffusion is
determined by oxygen saturation of the water layer interfacing with the air. In the case of
stagnant water the uppermost layer of water becomes saturated quickly and the convection
current of oxygen into the water slows down. The mass transfer rate which determines the
rate of diffusion (g/O2/m2/hour) varies in a wide range. It can be seen from a collection of the
data of several authors that the mass transfer rate has varied between 0.03-5.0 g/m2/hour
depending on the circumstances (Table 4).
In fish ponds the rate of diffusion is dependent on the mixing of water layers caused mainly
by wind action. The oxygen intake from the atmosphere by diffusion is 1.5 g/m2/day in small
ponds and 4.8 g/m2/day in big ponds, where the wind action is stronger.
Depending on oxygen saturation of the water, diffusion can show a reversed direction. In
case of over-saturation of the water oxygen diffuses to the atmosphere. Diffusion is assisted
by the mixing of water caused by wind action in this case.
It is well known that wind action has a good effect on the water quality of fish ponds through
increased diffusion. In the case of construction of new fish ponds the prevailing wind
direction has to be taken into account in order to utilize natural diffusion.
In intensive fish ponds where the oxygen budget of the pond water can be regulated
artificially, diffusion by wind action has less importance.
1.2.6 Artificial control of the dissolved oxygen content of water
Artificial control of the oxygen budget of water of fish ponds in this case means technical and
practical measures which have direct effect on the dissolved oxygen content of the pond
water.
Oxygen content of the pond water can be influenced by two methods; by change of flow rate,
and by aeration of pond water.
Figure 11. The length of the periods of oxygen shortage (0.3 mg/l) in the surface water
layer of a fish pond
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 15 of 38
Figure 12. The basic principles of fish pond aeration 1. Hydraulic type aeration
Figure 12. The basic principles of fish pond aeration 2. Air intake type aeration
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 16 of 38
Table 4 Coefficients of gas transfer for oxygen Source: Odum, H.: Primary production in
flowing water. Limnology Oceanography 1956 1/2 (102-107 p.)
In the case of intensively manured and fed fish ponds, where a significant part of the feed of
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 17 of 38
fish is produced in the water of the fish pond itself, increase of flow rate can not be applied
for oxygen saturation.
Artificial aeration means increasing the oxygen content of all or part of the pond water to
limits which ensure the oxygen supply to the fish without limiting the production at a given
management level.
In extensive fish culture, aeration of fish ponds has a "life-saving" role only in case of oxygen
deficiency. With the increasing of the intensity of pond fish culture, because of the
accelerated biological activity (intensive manuring, feeding, high stocking density) the natural
oxygen supply becomes more and more insufficient and will be a limiting factor in production.
Intensive aeration of fish ponds has not only a life-saving role, but it becomes one of the
basic factors of production, and ensuring optimal oxygen supply makes possible the maximal
utilization of the given biological possibilities.
During the planning of fish pond aeration, one can count on extended water surface areas as
potential air intake areas.
Oxygen over-saturation of the surface water layer can be decreased by mixing of the water,
and the oxygen can be uniformly distributed in the total water body of the pond. Mixing of the
water in shallow ponds such as fishponds has no influence on oxygen production of
plankton. Mixing the water during daytime can ensure that significant quantities of oxygen
are reserved for the night hours when consumption is predominant.
In pond fish farming the oxygen content of the atmosphere is utilized for enrichment of pond
water with oxygen. Basically there are two methods for oxygen enrichment. In the first one
energy is transferred to the surrounding air by some kind of air compressor and the air
penetrates into the water where it transmits a part of its oxygen content to the water. In case
of the second one energy is transferred directly to the pond water or other water source and
the water having a higher energy content will be able to take up air from the atmosphere and
dissolve part of its oxygen content. The principal schemes of these aeration processes are
shown in Figure 12.
A water pump is the basic device for the hydraulic type of aeration with which the energy
content of the water can be increased. The air intake device can be a cascade, a sprinkler,
an ejector or an air intake head. These are generally connected to the pump through a
pipeline. In the group of hydraulic type aeration devices, the surface aerators are shown in a
separate group in the figure, because of their special construction. Surface aeration can be
provided by a simple open impeller or by a centrifugal pump without housing, and its
construction is designed specially for pond aeration. The basic unit of air diffusion type
aeration devices is the air compressor which can be a root-type blower, a ventilator, a
compressor or a membrane pump. The air penetrates the water through porous material
such as a perforated tube placed in the pond.
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 18 of 38
In case of aeration with sprinklers the water jet comes out from the nozzle with high velocity
and falls into the water in drops, thus contacting the air on a large surface and dissolving
oxygen from it. When the water drops hit the water surface of the fish pond turbulence occurs
increasing the diffusion of air into the water. The water jet can be directed down into the
water surface forcing air bubbles into the water.
In aeration with an ejector the water is passed through a venturi-type diffusor where its
pressure decreases below the atmospheric pressure thus air can penetrate into the water.
Specially designed air intake heads can also be used for aeration. These usually involve a
propeller inside a pipe through which water is passing. The propeller is driven by the water
current and on the surface of the blade the pressure decreases and an air sucking effect
takes place.
Cascades can also be used for aeration, in which the water is broken into small drops,
increasing the interfacial area.
Hydraulic type aerators can be applied usefully when water is pumped through a pipeline but
they are particularly useful when a natural head is available.
Surface aerators are placed directly in the fish pond and due to the rotation of a paddle type
device, either with vertical or horizontal axis, the water is discharged into the air. These
aerators generate a vertical or horizontal water current in the fish pond that has an
advantageous effect on the oxygen budget.
During air diffusion the air is supplied by various types of compressors or blowers into the
water where it is diffused through a variety of diffusors. When the air is diffused through a
perforated pipe large bubbles of up to 10 mm in diameter are formed and when the diffuser is
a porous material fine bubbles of 2-5 mm in diameter are produced. When the bubbles
emerge and pass up to the water surface a part of their oxygen content is dissolved in the
water, and also a secondary upwards water movement is generated, creating a mixing effect.
Intensive fish culture systems are generally established in areas where there is a large
quantity and good quality of flow-through water. In such systems the oxygen requirement of
fish is ensured by the inflow water. This means the fish load capacity of these systems is
dependent on the rate of water flow. The water flow can not be increased beyond a certain
limit because of technical, economic and physiological reasons, although the other elements
of the system would make possible a higher stocking density. The fish load can be increased
to a certain extent by direct aeration of the water, but there are technical and economic
limitations on individual aeration of fish tanks.
By application of pure oxygen, the oxygen supply no longer limits the fish load of the system.
Furthermore the oxygen supply can be regulated and the safety of the operation increases.
The significant advantage of application of pure oxygen is the high mass transfer rate
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 19 of 38
between the pure oxygen and the water, because of high differences in concentration. In
application one has to take into account the costs of oxygen and the investment in devices to
dispense it. A well-designed and well-operated oxygen supply system can compensate for
the higher investment costs because of its low energy requirement.
Pure oxygen is available in gas or liquid form. For the supply of intensive fish culture systems
usually liquid oxygen is used, produced by cryogenic separation. The liquid oxygen of 99
percent purity is stored in tanks with vacuum insulation and evaporated before utilization.
Recently "oxygen generators" have been designed which can produce oxygen of 90 percent
purity, removing the nitrogen from the air by a molecule filter.
In order to minimize oxygen consumption devices are needed which ensure the most perfect
absorption of oxygen. The operating principle of these is the same as that of aeration
devices, but in order to increase the contact time between the gas and the water some
technical modifications are needed.
One is bubbling oxygenation where the oxygen gas comes in contact with the water by
breaking into bubbles. The rate of oxygen dilution depends mainly on the depth of the water
layer, the length of travel of bubbles in the water body and the rate of oxygen feeding. Higher
efficiency can be achieved by decreasing the bubble size, thus the contact time and the
contact surface increases. But the decrease of bubble size needs a significant quantity of
extra energy, and coagulation of bubbles also can happen. The efficiency of oxygen bubbling
can be increased by counterflow of oxygen and water (Figure 13/a). Undissolved oxygen can
be collected and circulated back to the oxygen supply system (Figure 13/b), or a closed
system can be constructed in which oxygen and water are continuously mixed (Figure 13/c).
Where oxygen is injected into the water flowing in a tube at a given point, the efficiency of
oxygen dissolving depends on the time the oxygen stays in the pipeline and on the pressure
in the tube. Oxygen can be fed into the pipeline through a Venturi tube, as shown in Figure
13/d.
U-tube oxygenation is shown in Figure 13/e, in which bubbles of oxygen are carried along
the water current. Thus the contact time and efficiency of oxygen dilution depends on the
difference of inflow and outflow water levels and on depth of the "U" tube. This process
seems to be very effective in fish culture practice because of its high efficiency, low energy
requirement and simplicity.
The above mentioned basic dissolving principles can be found simultaneously in the same
device as shown in Figure 13/f.
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 20 of 38
dissolved in the water relative to the concentration of oxygen in the gas under the prevailing
conditions of temperature and pressure. In fish pond conditions the gas means the
atmospheric air, although pure oxygen also gets into the fish pond water by the oxygen
production of phytoplankton and other water plants. In some intensive fish farming systems
pure oxygen is applied in order to meet the oxygen requirement of the fish.
where
The partial pressure of one component of a gas mixture is proportional to the volume fraction
of that component.
where
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 21 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 22 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 23 of 38
21 percent of the atmospheric air is oxygen thus the volume fraction is:
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 24 of 38
The oxygen concentration expressed in mole fraction can be converted into weight
fraction as follows:1/
1/ In the following equations the notations k-1 and m-1 are used to denote per kg
or per m3
where
thus
The weight fraction can be converted into weight concentration (Cs) as follows:
(kg . m-3)
where
Based on the equations given above, the weight concentration of oxygen at saturation (Cs)
can be calculated as follows:
(kg . m-3)
(g . m-3)
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 25 of 38
0 999.87 16 998.97
1 999.93 17 998.80
2 999.97 18 998.62
3 999.99 19 998.43
4 1 000.00 20 998.23
5 999.99 21 998.02
6 999.97 22 997.80
7 999.93 23 997.57
8 999.88 24 997.33
9 999.81 25 997.07
10 999.73 26 996.81
11 999.63 27 996.54
12 999.52 28 996.26
13 999.40 29 995.97
14 999.27 30 995.68
15 999.13
When calculating the pressure (p), the atmospheric pressure and the water head have to be
taken into account (1 mm H20 = 9.80665 Pa). In the case of a surface aerator, one has to
calculate only with the atmospheric pressure. The Cs values at normal atmospheric pressure
are shown in Figure 1.
In those places where the elevation is different from sea level, the atmospheric pressure can
be calculated with the "barometric level formula" as follows:
where
The normal atmospheric pressure at 45° north at sea level and at 273 K (0°C) temperature
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 26 of 38
is:
S0 = 1.2928 kg . m-3
T = temperature (K)
R = gas constant
The amount of oxygen that can be dissolved in the water by an aerator during a time unit can
be expressed as follows:
where
The solution of the differential equation when the initial condition is C0 is as follows:
The KLa modified mass transfer coefficient is a product of multiplication of the mass transfer
where
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 27 of 38
where
T = temperature (°C)
b = constant with a value between 1.016 and 1.047
In sewage treatment with bubbling aeration usually b = 1.02 is used during the
calculations
Generally:
The organic and inorganic materials in the water have an influence on KLa.
Kc La = D KLa
where
The Oxygenation Capacity (OC) expresses how many grams of oxygen can be dissolved in 1
m3 of water during one hour by the aerator investigated, at normal atmospheric pressure
when the water temperature is 10°C and its initial dissolved oxygen content is zero.
The relation between the Oxygenation Capacity and modified mass transfer rate is shown as
follows:
The value of OC at different temperature and atmospheric pressure can be computed with
the equation:
where
When the same aerator is used for the oxygenation of a larger water volume than 1 m3 less
oxygen can be dissolved. This is why total oxygen intake (Ot) is introduced.
Ot = V . OC (g h-1)
The specific total oxygen intake Ots shows the efficiency of the oxygenation related to the
power input.
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 28 of 38
(g h-1 kW-1)
where
5. DIMENSIONING OF AERATORS
The air intake type aerators can be classified according to the size of bubbles produced as
follows:
a) Fine bubbles dB = 1 to 5 mm
b) Medium bubbles dB = 5 to 10 mm
c) Coarse bubbles dB = larger than 10 mm
where
When fine and medium size bubbles are produced, the diameter of the bubbles is larger than
the size of the hole through which the air enters into the water . When a large bubble is
produced its diameter is smaller than the hole size.
The elevation velocity of the bubbles in ease of different bubble size is shown as follows:
In bubble aeration the following ratio is used as a reference to the efficiency of oxygen
dissolving:
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 29 of 38
where
The manufacturers of different aerators use characteristic curves that can be expressed as
follows:
or
where
Generally the air volume (Q) is related to normal atmospheric air. In this case:
S = 1.293 kg m-3
and
The equations above are related to a given water depth. The different parameters can be
converted from one water depth to another using the formula:
Table 7 shows the result of a test during which a bubble aerator (2.3 mm long 25 mm
diameter perforated plastic pipe with 1.5 mm diameter holes in two lines with a distance of 20
mm between holes) was utilized in a tank with a surface area of 7.5 × 17.5 m.
The scheme of the NOKIA fine bubble aerator is shown in Figure 14. The air intake part of
these aerators is made of porous polyethylene material, in pipe (HKP 600) or in disc (HKL
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 30 of 38
210) form.
They can be dimensioned using the curves given in Figures 15 and 16.
The Flygt 763 type fine bubble aerator is shown in Figure 17. The equation below shows how
much oxygen can be dissolved from 1 m air when the temperature of the water is 10°C, its
initial oxygen content is zero and when the aerator is placed 1 m below the water surface:
where
Q = the amount of air flowing through the aerator (the amount of air is calculated
for normal conditions, 0°C and 101325 Pa) (m3h-1)
The relation between the air flow and the required pressure is shown in Figure 17.
The cross-section of an ejector for fish pond aeration (Flygt type 4803, 4804) is shown in
Figure 18. The primary water flow (1) passes through a Venturi inlet (2) where its velocity
increases while its pressure decreases. The low pressure suction chamber (3) is connected
to the atmospheric air by a pipe (4) through which air enters the chamber. In the mixing pipe
(5) the air and the primary water are mixed together. As the air-water mixture passes through
the ejector its velocity decreases in the diffusor pipe while its pressure rises to the pressure
at the end of the pipe in the outside water. As an example, graphs are given in Figure 18 that
can be used for the dimensioning of Flygt type 4803 and 4804 ejectors.
Temperature
(°C)
9 1 019
10 1 000
11 0.982
12 0.964
13 0.946
14 0.928
15 0.911
16 0.895
17 0.878
18 0.861
19 0.845
20 0.830
21 0.815
22 0.799
23 0.784
24 0.770
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 31 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 32 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 33 of 38
Figure 17
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 34 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 35 of 38
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 36 of 38
The basic technical data of two paddle wheel type aerators are given below. These aerators
were tested in a concrete tank with 7.5 × 17.5 m surface area. The aerator has a horizontal
shaft with two paddle wheels on each end. The shaft is driven by an electric motor and chain.
The device is mounted on floats.
Table 7 Oxygen intake of paddle wheel type and perforated pipe type aerators
6. REFERENCES
Abeliovitch, A., 1967, Oxygen regime in Beit-Shean fish ponds related to summer mass fish
mortalities: preliminary observations. Bamidgeh, 19(1):3-15
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 37 of 38
Boyd, C.E., 1973, The chemical oxygen demand of waters and biological materials from
ponds. Trans. Fish. Soci., 102(3):606-11
Busch, C.C., J.L. Koon and R. Allison, 1973, Aeration, water quality and catfish production.
Pap. Am. Soc. Agric. Eng., (.73-559)
Chavin, W., 1973, Responses of fish to environmental changes. Springfield, Illinois, C.C.
Thomas Publishers, 459 p.
J.P.F. Scientific Corporation, 1971, Engineering methodology for river and stream
reservation. Water Pollut. Control Res. Ser., (16080.F.S.N. 10/71)
Nikolskii, G.V., 1963, The ecology of fishes. London, Academic Press, 352 p.
Oláh, J., A. Zsigri and A.V. Kintzly,1978, Primary production estimations in fishponds by the
mathematical evaluation of daily 0» curves. Aquacult. Hung., 1:3-14
Paulát, M., and P. Hartman, 1974, Overovani a posozovani ucinsosti ruznych typu pritoku a
nove aeracui techniky na sadkach. Cesk. Rybn., 2:13-9
Rappaport, V. and M. Marek, 1975, Results of tests of various aeration systems on the
oxygen regime in the Genosar experimental ponds and growth of fish there in 1975.
Bamidgeh. 28(3):35-49
Ruttkay, A., 1978, Ivadék utónevelés polikulturaban. Halászat, Tudományos melléklet, 71:16-
http://www.fao.org/docrep/x5744e/x5744e0m.htm 14/06/2013
Chapter 21 Aeration and Oxygenation in Aquaculture Page 38 of 38
Sarig, S. and M. Marek, 1973, Results of intensive and semi-intensive fish breeding
techniques in Israel in 1971-1973. Bamidgeh, 26(;2):28-50
Schroeder, G.L., 1975, Nighttime material balance for oxygen in fish ponds receiving organic
wastes. Bamidgeh, 27(3):65-74
Sowerbutts, B.J. and J.R.M. Forster, Gases exchange and reoxygenation. Schr.
Bundesforschungsanst. Fisch. ,Hamb., (16/l7)Vol. 1:199-217
Steeby, J.A., 1976, Effects of compressed air aeration in a heavily-fed farm pond stocked
with channel catfish. M.S. Dissertation, Auburn, Alabama
Warren, S.E., 1971, Biology and water pollution control. Philadelphia, W.B. Saunders Co.,
434 p.
Winberg, G.G., 1961, Novie dannie ob intenzivnoszti obmena u rib. Minsk, Beloruskovo
Gosudarstvennovo Universiteta Imena V.I. Lenina, 1(18):157-65
Zsigri, A., J. Oláh and P. Szabó, 1973, Átfolyóvizes, in situ metaboliméter a természetes
vizek oxigénfogyasztásának, termelésének, és diffuziójának mérésére. Hidrol. Közlöny,
Budapest, 5:216-8