CONCLUSION

​ o conclude, the cantilever retaining wall was designed


T
in phases such as excavation work, foundation soil
preparation, construction of the concrete wall block, concrete
block unit placement, grouting of the concrete wall block and
construction inspection of the concrete block. The overall
design of the cantilever retaining wall is shown below:

With all the checking for F.O.S on sliding, overturning and


bearing capacity passes the minimum requirement. There is
no steel reinforcement in the design.