MRO Test Operating Procedures

Introduction: Document below gives the instruction to Setup, Configure and carry out MRO Test on
JDSU RAN Advisor DT Software. The document is divided into four different parts:
A) JDSU RAN Advisor Setup/Installation.
B) Altair CPE Initial device Configuration/Unlocking.
C) In case of PC reboot during field testing, refer to this.
D) JDSU RAN Advisor device Connect procedure.
E) MRO Test Configuration and measurement.

A. JDSU RAN Advisor Setup/Install:

Installation of RAN Advisor 19.0-2 Beta 3 version on Window Mobile Workstation

Minimum recommended configuration of PC:

 Intel i7 Core Processor


 Windows7 64 bit (32 bit might be also ok for this testing)
 8 GB RAM (min 4 GB to start but not for intensive testing)
 250 GB SDD Hard Drive

Download and Execution:

1. Download RAN Advisor setup files from ftp2.jdsu.com, with these credentials- Username:
chinook, Password: 7fu43qs. Use FileZilla or any preferred FTP software or you can also use IE
8.0 onward to download files.
2. Go to ‘Bharti MRO Release’ Folder
3. Download ‘E6474A_xxxx.rar’, ‘PE160 xxx.exe’ and ALT3100_04_05_06_10_88.zip, files to
preferred location on local machine.
4. Once download is completed, unzip the E6474Axxx. RAR files.
5. Run the Setup.exe file (Preferably as Admin).
6. Follow the standard setup instructions.
7. Once setup of E6474A is complete successfully, run ‘PE160 xxx.exe’ patch file.
8. Once Altair Patch file is run, unzip ALT3100_04xxx.zip file.
9. Run setup.exe and install the Altair software in ‘Full Developer mode’ type only.
License Generation:

Generation of Locking Code on machine:

1. Open the "License Manager" software. (Windows Start à License Manager)

2. Click on the "Commuter License" -> "Remote Commuter License"

3. Save the locking code in .rlf format.


4. Following License needs to be installed to carry out MRO Tests:

Once locking code file (.rlf) is generated, pls email file to wsp.support@jdsu.com, mentioning
the above licenses and duration of license to be generated.
5. JDSU support would send back .rcl license file to you for x days license period for mentioned
licenses.
6. Once .rcl license file is received, follow the procedure to enable license.
7. Open ‘License Manager’ Commuter License Remote Commuter License’ (From Windows
Start à License Manager)
2. Click on ‘Install Remote License’ and load key from the .rcl file, by selecting ‘Get remote
authorization code from file’.
3. Pls send your License Manager Screenshot after Successful Import of License
B. Now as License is generated for JDSU RANAdvisor tool, we need to carry out initial setup for
AsiaTelco ODCPE PE-160 device, before we connect the device in JDSU tool.

Initial CPE Setup:


 Login to CPE via IE Browser. Use http://198.168.10.1

 Then open a new tab & use this link http://198.168.10.1/tool.html

It should have ALT3100_04_05_06_10_88_TF version mentioned in LTE FW


.

 Open connection Manager in “Altair Semiconductor  LTE ALT 3100  Connection


Manager

 Normally CPE is in Developer mode , we need to change it to ‘Technician PC Mode’, by right click
on Status Bar of the Connection Manage, there is option to change to Technician PC mode,
after that it will look like this: (Use IP address of 192.168.10.1 to connect in Technician mode)
 The CPE should be connected and show RSRP Strength as show above. You can also see
extended LTE Network information by right click on Status Bar:
 After verifying that CPE is connected properly, close the ‘Connection Manager’.
 Go to Start—> Altair Semiconductor  LTE ALT3100  Internet Tools  Run LTE Manager. LTE
manager runs in background.
I. You can verify that CPE is in unlocked mode by carrying out additional step below:
o Go to StartAltair Semiconductor  LTE ALT 3100  Debug View and see if you aren’t
getting following message in the window.

o If you are getting above messages, in Debug View window, pls refer to page 7 and
double check if the Altair CPE FW is ALT3100_04_05_06_10_88_TF, before you connect
CPE to JDSU RANAdvisor Tool.
C. There are few instances where it’s observed that, if you reboot the PC/Machine to which CPE
is connected, either you don’t see an RF Parameters on JDSU tool or Debug view is blank, as
shown below:
To solve no parameters reporting problem in JDSU tool or Blank ‘Debug view’, we recommend
following steps. If you have rebooted the PC during testing, check these additional steps:

 The PE160 device has DHCP server in-side, which allocates IP address to PC/Laptop. The IP
Address allocation can be from 192.168.10.10 to 192.168.10.100, which has been default range
of CPE DHCP allocations.
 Now, when PC is rebooted, this DHCP server allocates IP address from pool of listed IP address
(.10-.100).
1. Login to CPE Admin panel.
2. Go to ‘Command Prompt’ and check IP Address allocated to PC (ipconfig –all)
3. Now in CPE Admin panel check, http://192.168.10.1/relaylog.html is showing same IP
address (as per step 2), if yes jump to step ‘4’. If not then,
 Disable and then Enable Relay Log.
 Set IP Address of PC (same as shown in Step 2 of ipconfig -all). Apply settings.
 Soft reboot CPE (from Admin panel only)
4. One it’s confirmed that Relay Log settings and PC IP Address is same, move to following
standard steps:
 Open Altair Connection Manager and observe the device is latched to LTE
network and showing RSRP level.
 Close Connection Manager (Quit from Toolbar)
 Run ‘LTE Manager’ (from Start  Altair Semiconductor  ALT3100  Internet
Tools  Run LTE Manager)
5. Now Open JDSU RAN Advisor E6474A tool.
6. Import the standard project (if done ignore)
7. Probe the CPE (with standard settings)
8. Run the Sequencer in Live mode. It should show the RF readings now.

Please note, above steps have been verified to be working


steps, in the case of PC reboot. Please don’t skip any of the
steps above.
D. Now we have verified that CPE is connected, LTE manager is running in background and CPE
Debug view isn’t showing device lock up messages, it’s time to connect CPE to JDSU
RANAdvisor E6474A DT tool.

Connecting CPE to E6474A


II. Open JDSU RAN Advisor Beta Version.
III. Import the Project for ‘CPE’. (JDSU team would share the CPE project with DT team). You would
be in position to see Altair LTE device and Generic GPS (Un-probe) fashion.

IV. Configure the Trace port Setting for CPE as given below
V. Probe the CPE, after configuration on ‘Trace’ port is done. Check the icon symbol next to Altair
LTE device. It should get changed to ‘Connected’ mode after successful Probe.

VI. Probe the Generic GPS for given COM port.


VII. As now both Altair CPE and GPS are connected (Probed), you should see in RANAdvisor window
as,
E. Now both GPS and Altair LTE CPE are probed successfully, we now move ahead to configure
two measurements recommended by MRO test.
i) RSRP Measurement.
ii) FTP DL Throughput measurement.

Please note, both RSRP/FTP measurements are carried out in Stationary mode on grid
defined by TSTP guidelines. Please refer to details guidelines of by TSTP for RSRP and FTP DL
measurements.

Acrobat Document

o RSRP Measurements on JDSU RAN Advisor:


o To to Sequencer window. In the property in the Sequencer root node. We can find the
Auto stop after Sequencer completed. Select ‘Yes’ to choose ‘Stop after Sequencer
completed’, which would enable Auto stopping of the Sequencer.
o For RSRP Measurement is basically a ‘Wait timer’ Test for approx. 1 min (60 sec)
duration. You can see how WAIT TIMER test is added by right clicking on Altair
Device in Sequencer menu and adding new test.

o Please do the following configuration for WAIT TIMER test. Select duration ’60 Sec’

Configure it in Properties section for


Select WAIT TIMER from Sequencer 60 sec duration
menu
o FTP DL test Case for 5 minutes for Throughput measurement (Stationary
mode)
o You can see, FTP DL Test can be added below RSRP measurment as shown.

o From Sequencer menu, go to Altair LTE Device. In properties section, select ‘Dialup Adapter’
to ‘No’ and Network Interfaces to ‘LAN Network Adapter’ of PC. Pls note this is for Altair
Device properties, before configuring actual FTP test properties.

Select ‘No’ to Dialup Adapter and


Select Altair LTE device from Select ‘Network Adapter’ as PC’s
Sequencer menu default LAN Network Adapter (e.g.
RealTek) in properties section of
Altair LTE Device.
o Now select FTP DL Test from Sequencer menu and configure it as per given settings for 5
min duration.
a. Provide FTP Server Address, Authentication details, Path of Server directory and file
name (10 MB) to download for FTP Throughput testing. Please set ‘Time Out’ to 300
sec as per guidelines.

FTP DL test configuration, which


include Server IP, Auth details,
Directory path and File name details.
FTP DL test configuration File name
details.

o Once RSRP and FTP DL test configuration is done, user can test Sequencer in ‘Live mode’ to
verify settings, by individually selecting each Sequence.

Live mode Sequencer verification


o Once it’s found that Sequencer is working fine, please proceed to record individual logs by
selecting-deselecting each Sequence Separately and providing proper File nomenclature for
storing.
Shown below is Log recording for RSRP measurements.

Selected RSRP WAIT TIMER for Log Log File recording nomenclature.
recording.

o Recorded log files are stored at C:\Users\XXXX\Documents\Agilent Technologies\E6474A-


X

Store Project folders


location inside
C:\Users\Username\Docu
ments\Agilent
Technologies\E6474A-
X\Project Name
o It’s advisable that projects with its settings/sequencers config/logs are exported at the the
end of the day/or when necessary. Here are steps to export entire project data.
a. Open JDSU RAN Advisor E6474A
b. Go to ‘Project Manager’
c. Select the active project, right click and select export.

o
o