Professional Documents
Culture Documents
Details of Contraction Joint in Concrete Carriagewa Y 1106A
Details of Contraction Joint in Concrete Carriagewa Y 1106A
lwhere speciliedl
ct
,--- Sea6ng '7DOve and
approved joint sealant
ISee detois A Dr B
i'I Ilrg. No. Hl109l
/ Mid steel dowel bars. sow cut at both ends.
at mid-depth and 01 300mm cenlres
f---i---.-~--
± lOmm
/
~n
I
300 ± 50mm --------_.-
LWire lies
I
'"
_. -(
l I 'I I II
'" ? '" ?
Crocle bent
6mm dio. 01 tie bars
'\ " ..... PVC lighl
lilling dowel sleeve
300mm centres
bed~
!
'"
lIortor
(1 par t cement
10 J perts sandl
~ 0.125 mm polythene sheeti'lg
over luliwidth
• Dowel bll"s ere not recommended for Former Ilrg. No. H100J/l
June 94
slabs thinner than 150mm with general revision
REF. REVISION SIGNATURI DATE
HIGHWAYS DEPARTMENT
DETAILS OF CONTRACTION JOINT REFERENCE DRAWt-lG No.
~
IN CONCRETE CARRIAGEWA Y SCALE H 1106A
Diagrammatic