Technical note

Thermal imaging cameras: a fast and


reliable tool for testing solar panels.
Quality assurance is of fundamental importance for solar panels. The failure-free operation of
the panels is a prerequisite for efficient power generation, long life, and a high return on the
investment. To ensure this failure free operation a fast, simple and reliable method to evaluate a
solar panel's performance is required, both during the production process and after the panel has
been installed.

The use of thermal imaging cameras for solar panel evaluation offers several advantages.
Anomalies can clearly be seen on a crisp thermal image and - unlike most other methods - thermal
cameras can be used to scan installed solar panels during normal operation. Finally, thermal
cameras also allow to scan large areas within a short time frame.

In the field of research and development before actual problems or failures occur. But
(R&D) thermal imaging cameras are already not every thermal imaging camera is suited Thermogram with level and span in automatic
an established tool for the evaluation of for solar cell inspection, and there are some mode (above) and in manual mode (below).
solar cells and panels. For these sophisticated rules and guidelines that need to be followed
measurements, usually high performance in order to perform efficient inspections and applied when testing solar panels in the field,
cameras with cooled detectors are used to ensure that you draw correct conclusions. however, so the operator must ensure that
under controlled laboratory conditions. The examples in this article are based on there is a sufficient energy input by the sun.
photovoltaic modules with crystalline solar
However, the use of thermal imaging cameras cells; however, the rules and guidelines To achieve sufficient thermal contrast when
for solar panel evaluation is not restricted are also applicable to the thermographic inspecting solar cells in the field, a solar
to the field of research. Uncooled thermal inspection of thin-film modules, as the basic irradiance of 500 W/m2 or higher is needed.
imaging cameras are currently being used concepts of thermography are the same. For the maximum result a solar irradiance of
more and more for solar panel quality controls 700 W/m2 is advisable. The solar irradiance
before installation and regular predictive Procedures for inspecting solar panels describes the instantaneous power incident
maintenance checkups after the panel has with thermal imaging cameras on a surface in units of kW/m2, which can
been installed. Because these affordable During the development and production be measured with either a pyranometer (for
cameras are handheld and lightweight, they process, solar cells are triggered either global solar irradiance) or a pyrheliometer
allow a very flexible use in the field. electrically or by the use of flash lamps. (for direct solar irradiance). It strongly
This ensures that there is sufficient thermal depends on location and local weather.
With a thermal imaging camera, potential contrast for accurate thermographic Low outside temperatures may also increase
problem areas can be detected and repaired measurements. This method cannot be thermal contrast.

www.flir.com
Technical note

What type of camera do you need?


Handheld thermal imaging cameras
for predictive maintenance inspections
typically have an uncooled micro­
bolo­meter detector sensitive in the
8–14 μm waveband. However, glass is not
transparent in this region. When solar cells
are inspected from the front, a thermal
imaging camera sees the heat distribution
on the glass surface but only indirectly the
heat distribution in the underlying cells.
Therefore, the temperature differences that Thermal image without DDE (left) and with DDE (right).
can be measured and seen on the solar
panel’s glass surface are small. In order for visual images to be superimposed, is also
these differences to be visible, the thermal The so-called DDE (Digital Detail useful. Voice and text comments that can be
imaging camera used for these inspections Enhancement) functionality provides the saved in the camera along with the thermal
needs a thermal sensitivity ≤0.08K. To clearly solution. DDE automatically optimizes image image are beneficial for reporting.
visualize small temperature differences in the contrast in high dynamic range scenes,
thermal image, the camera should also allow and the thermal image no longer needs to Positioning the camera: take into
manual adjustment of the level and span. be adjusted manually. A thermal imaging account reflections and emissivity
camera that has DDE is therefore well suited Even though glass has an emissivity of
Photovoltaic modules are generally mounted for fast and accurate solar panel inspections. 0.85–0.90 in the 8–14 μm waveband,
on highly reflective aluminum framework, thermal measurements on glass surfaces
which shows up as a cold area on the thermal Useful features are not easy to do. Glass reflections are
image, because it reflects the thermal radiation Another useful feature for a thermal imaging specular, which means that surrounding
emitted by the sky. In practice that means that camera is the tagging of thermal images objects with different temperatures can be
the thermal imaging camera will record the with GPS data. This helps to localize faulty seen clearly in the thermal image. In the
framework temperature as being well below modules easily in large areas, e.g., in solar worst case, this results in misinterpretations
0°C. Because the thermal imaging camera's farms, and also to relate the thermal images (false "hotspots") and measurement errors.
histogram equalization automatically adapts to the equipment, e.g., in reports.
to the maximum and minimum measured In order to avoid reflection of the thermal
temperatures, many small thermal anomalies The thermal imaging camera should have a imaging camera and the operator in
will not immediately be visible. To achieve built-in digital camera so that the associated the glass, it should not be positioned
a high contrast thermal image continuous visual image (digital photo) can be saved perpendicularly to the module being
manual correction of the level and span would with the related thermal image. A so-called inspected. However, emissivity is at its
be needed. fusion mode, allowing the thermal and highest when the camera is perpendicular,
and decreases with an increasing angle.
1 A viewing angle of 5–60° is a good
Emissivity
compromise (where 0° is perpendicular).
0.8

0.6

0.4

0.2 Reflectance

0 15 30 45 60 75 90
Viewing angle recommended (green) and to be
avoided (red) during thermographic inspections.
Angle of incidence (DEG)

Angle dependence of the emissivity of glass


cooling and thus will reduce the thermal
gradient. The cooler the air temperature,
the higher the potential thermal contrast.
Performing thermographic inspections in
the early morning is an option.

Another way to enhance thermal contrast


is to disconnect the cells from a load, to
prevent the flow of current, which allows
heating to occur through solar irradiance
alone. A load is then connected, and the cells
In order not to draw false conclusions you need Thermal image made using a FLIR P660 camera
to hold the thermal imaging camera under a
are observed in the heating phase.
on a flight over a solar farm. (Thermogram
correct angle when inspecting solar panels. courtesy of Evi Müllers, IMM)
Under normal circumstances, however, the
Long distance observations that indicate solar panel faults in long system should be inspected under standard
It is not always easy to achieve a suitable distance measurements using a telephoto operating conditions, namely under load.
viewing angle during the measurement lens. Depending on the type of cell and the kind
set-up. Using a tripod can provide a of fault or failure, measurements under
solution in most cases. In more difficult Looking at it from a different perspective no-load or short-circuit conditions can
conditions it might be necessary to use In most cases installed photovoltaic provide additional information.
mobile working platforms or even to fly modules can also be inspected with a
over the solar cells with a helicopter. In thermal imaging camera from the rear of a Measurement errors
these cases, the longer distance from the module. This method minimizes interfering Measurement errors arise primarily due to
target can be advantageous, since a larger reflections from the sun and the clouds. In poor camera positioning and suboptimal
area can be seen in one pass. To ensure addition, the temperatures obtained at the ambient and measurement conditions.
the quality of the thermal image, a thermal back may be higher, as the cell is being Typical measurement errors are caused by:
imaging camera with an image resolution measured directly and not through the • too shallow viewing angle
of at least 320 × 240 pixels, preferably 640 × glass surface. • change in solar irradiance over time (due
480 pixels, should be used for these longer to changes in sky cover, for example)
distances. Ambient and measurement conditions • reflections (e.g., sun, clouds, surrounding
When undertaking thermographic buil­dings of greater height, measurement
The camera should also have an inspections, the sky should be clear since set-ups)
interchangeable lens, so the operator can clouds reduce solar irradiance and also • partial shadowing (e.g., due to surrounding
switch to a telephoto lens for long distance produce interference through reflections. buildings or other structures).
observations, such as from a helicopter. It is Informative images can, however, be
advisable, however, to only use telephoto obtained even with an overcast sky, provided What can you see in the thermal image
lenses with thermal imaging cameras that the thermal imaging camera used is If parts of the solar panel are hotter than
that have a high image resolution. Low sufficiently sensitive. Calm conditions are others, the warm areas will show up clearly
resolution thermal imaging cameras will be desirable, since any airflow on the surface in the thermal image. Depending on
unable to pick up the small thermal details of the solar module will cause convective the shape and location, these hot spots

This thermal image shows large areas with Thermal image of the back of a solar module taken with a FLIR P660 camera. Its corresponding
elevated temperatures. Without more information, visual image is shown on the right.
it is not obvious whether these are thermal
anomalies or shadowing/reflections.
Technical note

Conclusions
The thermographic inspection of
photovoltaic systems allows the fast
localization of potential defects at the cell
and module level as well as the detection
of possible electrical interconnection
problems. The inspections are carried out
under normal operating conditions and do
not require a system shut down.

These red spots indicate modules that are consistently This hot spot within one solar cell indicates physical
For correct and informative thermal images,
hotter than the rest, indicating faulty connections. damage within the cell. certain conditions and measurement
procedures should be observed:
warmer ‘patchwork pattern’, the cause can • a suitable thermal imaging camera with
usually be found either in defective bypass the right accessories should be used;
diodes, in internal short-circuits, or in a cell • sufficient solar irradiance is required
mismatch. (at least 500 W/m2 – above 700 W/m2
preferred);
Shadowing and cracks in cells show up • the viewing angle must be within the
as hot spots or polygonal patches in the safe margins (between 5° and 60°);
thermal image. The temperature rise of a • shadowing and reflections must be
cell or of part of a cell indicates a defective prevented.
cell or shadowing. Thermal images
This thermal image shows an example of the so-called obtained under load, no-load, and short- Thermal imaging cameras are primarily
‘patchwork pattern’, which indicates that this panel has
a defective bypass diode. circuit conditions should be compared. A used to locate defects. Classification and
comparison of thermal images of the front assessment of the anomalies detected
and areas can indicate several different and rear faces of the module can also give require a sound understanding of solar
faults. If an entire module is warmer than valuable information. Of course, for correct technology, knowledge of the system
usual that might indicate interconnection identification of the failure, modules inspected, and additional electrical
problems. If individual cells or strings of showing anomalies must also be tested measurements. Proper documentation
cells are showing up as a hot spot or a electrically and inspected visually. is, of course, a must, and should contain
all inspection conditions, additional
measurements, and other relevant
Error type Example Appears in the thermal image as information.
Impurities and gas pockets A ‘hot spot’ or ‘cold spot’
Manufacturing defect Inspections with a thermal imaging
Cracks in cells Cell heating, form mainly elongated camera - starting with the quality control
in the installation phase, followed by
Cracks Cell heating, form mainly elongated regular checkups - facilitate complete and
Damage
simple system condition monitoring. This
Cracks in cells A portion of a cell appears hotter
will help to maintain the solar panels'
Pollution functionality and to extend their lifetime.
Using thermal imaging cameras for solar
Temporary shadowing Bird droppings Hot spots
panel inspections will therefore drastically
Humidity improve the operating company’s return
Defective bypass diode on investment.
(causes short circuits and N.a. A ‘patchwork pattern’
reduces circuit protection)
For more information visit www.flir.com
Module or string of modules A module or a string of modules is or contact:
Faulty interconnections
not connected consistently hotter
FLIR Commercial Systems B.V.