You are on page 1of 48
INTERNATIONAL Iso STANDARD 15589-1 First edition 2008-11-15 SS UEEEEDUEEEEEEEEDEEE EES Petroleum and natural gas industries — Cathodic protection of pipeline transportation systems — Part 1: On-land pipelines Industries du pétrole et du gaz naturel — Protection cathodique des systémes de transport par conduites — Partie 1: Conduites terrestres a Reference number 1SO 15589-1:2003(E) ©180 2003, 1SO 15589-1:2003(E) PDF disclaimer ‘This POF file may contain embedded typefaces. In accordance with Adobe's lcensing polcy, ths fle may be printed or viewed but ‘shall not be edited unless the typefaces which ere embedded are licensed to and installed onthe computer performing the eating. In downloading this fe, partes accept therein the responsibly of not infinging Adobe's Boensing policy. The ISO Cental Secretariat ‘eccepts no liably in this area. ‘Adobe is trademark of Adobe Systems Incorporated, Details of the sofware products used to crete this POF fie can be found in the General Ino relave to the fle: the POF-creation ‘parameters were optimized fr printing. Every care has been taken to ensure that the fle sulabe for use by ISO member bodes. n the unikely event that a problem relating ots found, please inform the Central Secretariat atthe address given below. © 180.2003, [Al rights reserved. Uniess otherwise specified, no part of this publication may be reproduced or utlzed in any form or by any mesns, ‘loctonic er mechanical, including photocopying and micrafim, without pemssion in wring from eltner ISO at the address below of 180% member body nthe country ofthe requester. 180 copyright offce Case postale 56» CH.1211 Geneva 20 Tol +4122 749001 11 Fax +41 227490047 smal conyrighi@is0.or9 Web woawis0.079 Published in Swizeriand ii (©150 2003 — Al ights reserved 180 15589-1:2003(E) Contents Page 104 102 103 (© 1S0 2003 — Al rights reserved Normative references Terms and definitions. ‘Symbols and abbreviations . Design requirements .. General Predesign investigations... Electrical isolation Electrical earthing, Electrical continuity, Current requirements ‘Type of CP system and selection of sit Impressed-current systems . Current output control and distribution Galvanic-anode systems General Test facilities at cased crossings. Test facilities at isolating joints. Drain-point test facilities. Miscellaneous monitoring facilities Special facilities... ‘Temporary protection. 18 Lightning protection 18 ‘Surge arrestors .. 8 CP cables and cable connections... Monitoring stations and distribution boxes. Commissioning . General. Equipment tests, ‘System tests.

You might also like