HEAT TREATMENT AFTER FORMING REVIEW

(As Per UCS-79 of ASME Sect. VIII Div. 1)


HEAD:
[A]. % Extreme Fiber Elongation Calculation :
Description LH Head RH Head
Head Inner Diameter 1000 1000
Head Nominal Thickness (t) 20 20
Final Centre Line Radius (Rf) 180 180
Blank Diamter (Db) (Approximate) 1206.00 1206.00
Original Centre Line Radius (Ro) INFINITY INFINITY
% Extreme Fiber Elongation ( 75*t*(1- Rf/Ro) / Rf) 8.33% 8.33%

HEAT TREATMENT REQUIRED: YES


The extreme fiber elongation exceeds 5 percent. Heat treatment per UCS-56 may be required. See U
or (5).

[B]. % Extreme Fiber Elongation Calculation per para 13.2.12.3 OF 32-SAMSS-004 :


Description LH Head RH Head
Head Inner Diameter 1000 3962.4
Head Nominal Thickness (t) 20 20
Final Outside Diameter of head after forming (Df) 1040 4002.4
Blank Diamter (Db) (Approximate) 1206.00 4778.65
% Extreme Fiber Elongation 100ln [ Db / (Df - 2t)] 18.73% 18.73%

HEAT TREATMENT REQUIRED: YES

Formed Heads will be Heat Treated (Normalized) after forming since the % of extreme fiber elongati
above 10%. Refer Project spec 32-SAMSS-004, clause 13.2.12.3..