Professional Documents
Culture Documents
WaterTech August2009 PDF
WaterTech August2009 PDF
9 August 2009
Presence of silica in boiler feed water is harmful A solids contact type clarifier, with solids
as silica tends to volatilize along with steam and recirculation, provides ideal conditions for
gets deposited as glassy and hard scales on the coagulation of non-reactive silica. As it is
turbine blades. This can be costly because of present in small quantities, recirculation of
resultant shutdowns for the maintenance of solids ensures adequate contact between the
turbines. colloidal particles and the coagulant.
Keeping boiler drum silica values under control Coagulation, at best, is a physical process and,
will then mean higher blowdown and loss of under ideal conditions, one can therefore expect
efficiency. to remove up to 80 to 90% of non-reactive silica
present in water.
Working of a High Rate Solids Contact Clarifier
Ultra Filtration: The best way of ensuring UF is a pressure activated process employing
maximum removal of non-reactive silica is to a semi-permeable membrane with asymmetric
remove the bulk of it in the pretreatment plant structure (Fig. 1) and can be effectively used for
and polish it with an ultra filtration (UF) system removal of non-reactive silica.
installed at the outlet of the mixed bed (MB) unit.
Fig. 1
Cross Flow Over Membrane Surface
Membranes with a molecular weight cut-off a tighter membrane with an MWCO of 10,000
(MWCO) of 100,000 remove upto 99% of removes upto 99.8% (Table 1).
non-reactive silica present in feed while
Table 1
Being physical separation, the UF membrane is For existing power plants using conventional ion
best suited to remove colloidal silica as compared exchange DM, the solution is to retrofit the plant
to other pretreatment processes described earlier with hollow fibre UF membranes downstream of
which involve complex monitoring, chemical the MB unit to physically retain and remove any
addition and manpower intervention & experience colloidal silica that may have escaped the
to ensure successful removal. pretreatment and the ion exchange beds.
Or
A chart showing UF performance at an installation for removal of colloidal silica is shown in Fig. 2.
Fig. 2
UF Performance - Colloidal Silica Removal
The effectiveness of the system can be seen from the above results.
A number of similar installations supplied by us are in operation for various power stations in India.
08092.5K
Ion Exchange (India) Ltd., Ion House, Dr. E. Moses Road, Mahalaxmi, Mumbai-400 011, India. Phone: 91-22-3989 0909/3047 2024
Fax: 91-22-2493 8737 E-mail: hocro@ionexchange.co.in Website: www.ionindia.com
Phone 3989 0909 in Chennai, Delhi, Kolkata, Mumbai; prefix 022 from other cities.