You are on page 1of 4
PROJ.NO. 4883-030 PAGE: tof CLIENT: | KAR GROUP SPEC: 108206 REV. 1 UNIT NAME: 8200, 8300, Bg00 (ON MODULE) REQ: 4€53.020-0520.003 LOCATION: ERBIL REFINERY Date: October 28, 2010 PRESSURE DIFFERENTIAL INDICATORS 10 GENERAL 1.1 Vendor shail provide protection adequate for shipment and storage of instruments, {All openings and exposed parts shall be protected, so 2s to prevent debris from entering. All flanges and threaded connections shall be protected against damage using wood steel, andor plastic protectors. 4.2. Vendor shail clearly state any. and all exceptions in 2 separate section of quote labeled “Exceptions & Clarifications" Failure to do so shall imply vendor has no exceptions. 1.3 Inthe event @ model number given conflicts with other data provided, the model number shall be ignored, and the data provided wil govern, Notify Ventecr prior to making any changes, 1.4 Unless noted otherwise all electrical accessories shall be approved for use in a Class 1 Division 2 Groups © & D location. 1.8. Vendor data shall be provided in strict accordance with Attachment 1 "Drawings & Data Schedule" 1,6 Gauges to be 6” dial size, 3168S wetted parts and 1/2"NPT process connections. 1.7 Each device shall be supplied complete with 2 permanently attached stamped stainless eteel tag containing the complete tag number listed on the specification, TT tae arta Ore [ Appr ToT [SSE FORPORORRSE eu “1 | 4725710 [REVSON RELEASES HOLD ON UNT “GHD AND REVSES PROCESS DATA AND TKG OMBERS. sr T [ i i t confidential Tris document and the Infomation conained herein is confidertl and may nat be ceclosed to my persons of copied or epreduoad axcept es period invaring oy Ventoch Enginarsntomavonal Corp. Al cemens of bye document a al cles Ot are ie property of Ventech Erghnoers teat (Corp. ands can, ae lent ou cn the express conton hat hey are subject 0 tum upen demand. NOTES eT PRESSURE DIFFERENTIAL INDICATORS SEEET NOT] ey [bars REVISION] __1-05.200 {SIP $162070" PURCHASE] CONTRACT 2 | SJP[arasiz0t0o | REVISION | __ 4653-030 REG 4859-030.0520-003. BY SP Seale or | Scale Tagnumeer | piano. |Sesle RangelOP Rangel Chan’ | Factor Service D- 100°] 0-100 manr_| intzo | SARE 200-208 | B-PD-202 STRIPPER FEED 4. Flow readings shall be ealbrated based on the square root factor of the ciferental pressure measurement. 2. NACE MRO175 rating is required. NOTES PRESSURE DIFFERENTIAL INDICATORS [SHEET NO] Sy [SATE REVISION 1.05 200. = [Si ara20 10 | PURCHASE! 2 [ssp [toze2019) REVISION | 4859.00 REG 14659-090-0520.009 se Scale or | Seale TagNumber | PaiD No. [Seale RengelDP Rangel Char _| Factor Service peoorios | e-Poa0e | 0-20mamq O72 | sq. Rt ‘STABILZER FEED FROM B.-P-201A8 HO 1. Flow reacings ehall be calibrated basod on the square root factor ofthe differential pressurs measurement

You might also like