ABV Technology Pte Ltd
Avec
Report No. : P15-024-spt-001
TEST REPORT
Report Date : 6 March 2015 Page 1 of 2
SPT HAMMER ENERGY MEASUREMENT
Client 1 Ground Instrumentation & Engineering Pte Lid
50 Jalan Benaan Kapal
Singapore 399641
Test Site 1 Seletar Aerospace View
fest Date + 2March 2015
SPTHammor =: SPT H-1
Test Method + ASTM D4633 - 10
Test Equipment —: Pile Driving Analyzer : Model PAX - Serial No. 3862L
Instrumented Rod : Serial No. 277BW / Length - 0.6 m
Strain Transducers : Serial Nos. 277BW-1 & 277BW-2
‘Accelerometers : Serial Nos. K1768 & K1769
Software : PDA.W Version 2014.119
Weighing Scale : OHAUS Model SD75 Serial No. : 0610530JLQ
Attachments 2 1. List of Abbreviations (1 sheet)
2. Selected Graphical Plot of Test Results (1 sheet)
‘The test repor shall net be reproduced, except in ful, without the written approvat of ABV,ABV Technology Pte Ltd vex
Report No. : P15-024-spt-001
TEST REPORT
Report Date : 6 March 2015 Page 2 of 2
SPT HAMMER ENERGY MEASUREMENT
SPT HAMMER SERIAL NO.: SPT H-4
BOREHOLE
Ref: BH Diameter: 100mm Depth: 150m
DRILL RIG
Type: — Rig-1 Rig Operator: R. Arjunan
ROD /SAMPLER
DriltRod Type: BW Rod Segments (m): 3+3+3+3+ 3 (bottom to top)
Sampler Length: 0.6m Total Length: 16.2m (instrumented rod top to sampler base)
Sensor to Sampler Base: 159m
‘SPT HAMMER
Ram Mass: 63.70 kg Anvil Mass: 21.15 kg Mean Ram Drop Height: 756 mm.
‘Theoretical Energy: 0.4724 kN-m
RESULTS
SPTN-value: 39 Mean Measured Energy (EMX): 0.2939 kN-m
Min. / Max. EMX Value: 0.2373/0.3608kN-m Standard Deviation: 0.0275 kN-m
0.2039
Energy Ratio, E: = ———— = 0.62 (62%)
0.4724
‘The test repon shall not be reproduced, except in ful without the writen approval of ABV.