ABV Technology Pte Ltd Report No. : SPT18/07/026-02 TEST REPORT Report Date : 3 August 2018 Page 1 of 2 SPT HAMMER ENERGY MEASUREMENT Client 1 Ground Instrumentation & Engineering Pte Ltd 62 Ubi Road 1 +#01-32 Oxley Bizhub 2 ‘Singapore 408734 Test Location: ABV Workshop Test Date + 2 August 2018 SPTHammer —: SPT-19 Test Method 1 ASTM 04633 - 16 Test Equipment —: Weighing Scale : CHAUS Model SD75 Serial No. : 0610539JLQ. Drop Height Device : Scale Rule Pile Driving Analyzer : Model PAX - Serial No. 3862L Instrumented Rod : Serial No. 2778W / Length -0.6 m ‘Accelerometers : Serial Nos. K5756 & K5831 Software : PDA-W Version 2017.22 Attachments: 1. Table of Results and Selected Graphical Plot (1 sheet) ‘Comments : The hammer's ram mass, ram drop height and total mass comply with the requirements of BS EN ISO 22476-3:2005+A1:2011 Clause 4.4, 1. The results reported herein have been performed in accordance withthe laboralory’s terms of accreditation under the Singapore Accrediation Councl- Singapore Laboratory Accreditation Scheme, 2, This report sha not be reproduced except ul unless the management representative of ABV Technology Private Limited has given approval in wring, ‘Accredited ABV Technology Pte Ltd tsboratry eT 'SACSINGLAS. A Report No. : SPT18/07/026-02 TEST REPORT Report Date : 3 August 2018 Page 2 of 2 SPT HAMMER ENERGY MEASUREMENT ‘SPT HAMMER SERIAL NO.: SPT-19 PHYSICAL PROPERTIES Ram Mass : 63.70 kg Anvil Mass: 21.15kg Total Mass : 98,30 kg Ram Drop Height :_757 mm Theoretical Energy : 0.4730 kN-m BOREHOLE Ref : ABV-02 Dia, Depth: 137m DRILL RIG. Type: B10 Rig Operator: Joti ROD / SHOE Drill Rod Type: BW Rod Segments (m) : 3 +3+3+3¥+ 1.5 (bottom to top) Shoe Length: 0.7 m Total Length : 14.8m (instrumented rod top to shoe base) ‘Shoe Type : Solid Cone Sampler Sensor to Shoe Base : 14,5m ERGY No. of Blows : 10 Mean Measured Energy (EMX) : 0.9553 KN-m Min. | Max. EMX Value : 0.3267 / 0.3749 kN-m Standard Deviation : 0.0161 kN-m 0.3553 Energy Ratio, Ey = "= 0.75(75%) 0.4730 ees Ai Authorised Signatory, ‘Cheong Kok Leong Director 1. The results reported herein have been performed in accordance with the laboratory’ terms, of accreditation under the Singapore Accredtaon Council - Singapore Laboratory Accreditation Scheme, 2, This report shall not be reproduced except in fl, unless the management representative of ABV Technology Private Limited has given approval in writng ABV (Singapore) Case Method & iCAP® Results Page 1 PDIPLOT2 2016.2.57.6 - Printed 03-August-2018 GIE-SPT-19 SPT OP: KZ. Date: 02-August-2018 AR: 11,70 on™ ‘SP: 77.3 kNIm* LE 145m EM: 206,843 MPa WS: 5,123.0 mis Jc: 0.60) Displaying BN:3 Fores m coo ——Eay Aig] M@14.5m (6.35 mis) — F12 E Beta @ 10.9 m 7a@ 4am 10 @ p.m EMIX: Max Transferred Energy EF2: Energy of FA2 DMX: Maximum Displacement FMX: Maximum Force CSX: Max Measured Compr. Stress TSX: Tension Stress Maximum MX: Maximum Velocity ‘AMX: Maximum Acceleration RX: Max Case Method Capacity (JC=0.6) BL# Depth = EMX = -EF2. DMX FX OSX TSK _VMX AMX _RXG m okNem kN-m = mm = KN MPa MPasms g's KN 2 © 13:7 0.3267 0.2709 9 116 99 31384 3,150 49 3 13:7 0.3693 0.3267 9 164 141 34 «4513685 4 137 03714 03226 9 169 144 35-486 4.021 60 5 13.7 0.3663 0.2879 10 136-116 34451 3980 6 137 03581 0.3010 9 140 © 119 36-448 3.92056 7 437 03319 0.2771 O07 002) 929.79 1 200260) 8 13.7 0.3749 0.3150 100182130 37471 3802 55 9 137 0.3588 0.3047 9 148 126 32 456 3,753 52 10 137 0.3560 0.2960 9 133 114 at 432 3,595 58 ii 137 0.3395 0.2815 9 121 40335 3.98 3.278 51 Average 0.3553 0.2994 9 139 118 35 4.35 3.613, 57 Std. Dev. 0.0161 0.0179 0 19 16 3 036 351 5 Maximum 0.3749 0.3267 10 169014414186 4,021 64 Minimum 0.3267 0.2709 8 107 02 3179 2042940) Total number of blows analyzed: 10 BL# Sensors 2-11 FA: [277BW-1] 214.0 (1.00); F2: [277BW-2] 213.1 (1.00); At: [K5831] 342.0 (1.00); ‘AZ; [K5756] 348.0 (1.00) a

You might also like