1.0 SETTING
If any zones are in fault the speaker will give a pulsed tone and the LED for that zone will be lit.
Return to the panel and press the "#" key or enter the user code to abort the exit procedure. Investigate the
fault and correct if possible, then start the exit procedure again. If any zone on the exit route is open (door
open or detector tripped) then the speaker will give a pulsed tone on exit but should go to a steady tone
when the zone closes If you are unable to correct the fault contact your Installer. If you do not complete the
exit procedure before the exit time runs out an internal alarm will occur. Enter your user code to stop the
alarm. See section 3.4 to reset the system.
2.0 UNSETTING
Enter by your usual route, the Speaker will begin to sound. Do not stop, go directly to the keypad.
Enter the four digit code, the speaker will stop and the control panel will return to the 'DAY' mode. If the exit
time has less than 10 seconds remaining the speaker will emit a quick pulsing sound to indicate "HURRY
UP".
3.0 FAULTS
NOTE. If an internal speaker is not fitted in your control panel then the tones given are limited and may not
relate to the above information. Contact your Installer regarding the fitting of a 16 ohm extension speaker.
<CODE> * 9 1 4 5 6 7
Pressing the # key will change between viewing the 'SET' and 'UNSET' logs. This may be done at
any time. The log review will automatically end after 15 seconds if no keys are pressed.
Enter the four digit user code, the speaker will emit a steady sound and the exit time start. Press
the * key followed by the 9 key, then press the 3 key. The log routine will start viewing 'DAY' 1 'SET'
KEY VIEW
1 LOG 1
2 LOG 2
3 LOG 3
4 LOG 4
5 LOG 5
6 LOG 6
7 LOG 7
8 LOG 8
9 LOG 9
0 THE LAST ALARM
You should test your system at regular intervals, to aid this a walk test mode is prov ided. You are
allowed to test all ALARM devices. DO NOT TEST ANY PERSONAL ATTACK BUTTONS.
Enter the four digit user code, the speaker will emit a steady sound and the exit time start. Press
the * key followed by the 9 key, then press the 4 key. The speaker will emit a low level steady tone.
As you test each device the internal sounder will give a loud pulsing tone to indicate the correct operation
of that device. The zone number LED will light. When the device test is over the sounder will stop and the
zone LED will go out. The speaker will emit a low level steady tone as before. Report any faults to your
Installer. Press the * key to finish.
IMPORTANT.
If you have any problem with your system or any difficulty understanding it’s operation please contact your
Alarm Installer immediately. They will be pleased to help.
This product should only be used for domestic, commercial and light industrial use only.