AspenTech  products  run  as  32‐bit  applications  on  32‐bit  Windows  XP  (SP3),  32‐bit 
Windows Vista, and 32‐bit and 64‐bit Windows 7 operating systems.  
1. Obtain  the  AspenONE  7.3  DVD  (Engineering  DVD  1)  installation  files  from  the 
Department  IT  specialists  (che.it@ttu.edu).  You  can  obtain  them  in  one  of  three 
ways. 
a. Bring  a  flash  drive,  hard  drive,  or  computer  to  hold  the  files.  Approximately  9 
GB of space is required (~ 40 min transfer). 
b. Bring  a  blank  dual  layer  DVD  to  the  specialist  and  let  him  provide  you  a  pre‐
burned copy of the software in return (1½ hr burn).  
c. Give  the  IT  specialist  $2  and  let  him  provide  you  a  pre‐burned  copy  of  the 
software in return. 
2. Install  Microsoft  SQL  Server  Express  (Service  Pack  3)  prior  to  installing  Aspen. 
Insert the Aspen Engineering DVD 1 into your computer’s DVD drive. Navigate to 
the folder \3rd Party Redistributables\Microsoft SQL Express 2005 SP3. Click on the 
file  SQLEXPR  to  install  the  database  server.  Follow  the  directions  given  by  the 
installer. 

 
   
Page 2 of 24 
 
 
3. Follow  the  directions  given  by  the  installer  until  you  get  to  the  Feature  Selection 
screen. Select the products as indicated in the image below. Click “Next”. 

 
4. Click “Next” on the next two screens without changing any options. When you get 
to the Authentification Mode screen (below), select “Mixed Mode” and click “Next”.  

Select Mixed 
Mode. 

 
Page 3 of 24 
 
5. Click  “Next”  on  the  next  three  screens  without  changing  any  options.  SQL  Server 
Express will install. When finished, you will see the screen below. Click “Next”, then 
“Finish”  on  the  following  screen.  Installation  of  pre‐requisites  for  Aspen  is  now 
complete. 

 
6. Now launch the Aspen Installer Program.  

7.  
Page 4 of 24 
 
8. After the AspenTech Installation browser loads up, select the “Products” tab.  

 
9. A pop‐up will appear, indicating the need for a valid license. Select “OK”. 

 
10. The Installer Configuration Wizard will pop up. Select “Next”. 

 
Page 5 of 24 
 
11. Select “License Server” for the license configuration type. Click on “Next”. 

 
12. The  “License  Servers”  window  will  pop  up.  Enter  129.118.23.240  in  to  the 
license server field. Click “Add Server”. Click “Next”.  

 
a. Note:  your  computer  must  be  able  to  “see”  the  Chemical  Engineering 
license  server  in  order  for  AspenPLUS  to  run.  The  license  supports  150 
simultaneous users, regardless of location.  
Page 6 of 24 
 
b. If  you  connect  to  TTUnet  on  campus,  either  wirelessly  or  with  a  wired 
connection, your computer will automatically find the server.  
c. If  you  connect  from  off‐campus  through  a  third‐party  Internet  Service 
Provider, you must set up a Virtual Private Network (VPN), so that you can 
tunnel through the TTU firewall. 
d.  Setting  up  a  VPN  only  requires  your  Eraider  username  and  password. 
The details on setting up a VPN to TTUnet are given on the Information 
Technology  website  at 
http://www.depts.ttu.edu/ithelpcentral/solutions/VPN/index.php.   
13. The  “Determining  Product  Licenses”  window  will  pop  up.  When  the  installer 
completes its survey of the licenses on the server, click “Next”. 

 
14. You  will  return  to  the  Installation  Browser,  which  will  display  the  ASPEN 
Engineering  Suite.  For  process  simulation  and  modeling  (Aspen  Plus  or  Spen 
HYSIS), select Aspen Engineering and click on “Install”. For installation of heat 
exchanger design and rating tools and/or economic evaluation tools, click here.  

 
Page 7 of 24 
 
15. The ASPEN Engineering V7.3 Setup program will open. Click “Next”. 

 
16. Accept the terms of the License Agreement and click “Next”. 

 
Page 8 of 24 
 
17. On the Computer Configuration Type window, select “Standard Install”. 

 
18. In the window “Choose Destination Location”, confirm that you wish to use the 
default location, or browse to a different location. Click “Next”. 

 
Page 9 of 24 
 
19. In “Feature Selection for Aspen Engineering V7.3”, select the products you wish 
to install. The most common Aspen software used in the department is “Process 
Modeling  (Aspen  Plus).  Other  useful  products  are  indicated  in  the  screen  shot 
below. Click “Next”. 

 
20. The  installer  now  checks  if  the  proper  SQL  Server  is  running.  If  you  see  the 
following  window,  click  Ok  to  continue  installation.  After  Aspen  installation 
completes,  reinstall  SQL  Server  Express  2005  and  specify  the  “SQL  Server 
Authentication Mode.” This is also known as the “Mixed Mode” 

 
Page 10 of 24 
 
21. The  window  “Choose  Working  Files  Folder  Location”  will  open.  This  is  where 
your ASPEN simulations will be stored. Accept the default location or browse to 
an alternate location. Click “Next”. 

 
22. A window should pop up asking to choose compilers for Aspen Properties, click 
“Next.” 

 
Page 11 of 24 
 
23. The next window will ask for username, password and domain, leave the fields 
blank  and  check  the  box  that  says  “Skip  username/password  validation”,  then 
select “Next.” 

 
24. The “Ready to Install the Program” window will appear. Click “Install”. 

 
Page 12 of 24 
 
25. The  installation  dialog  box  will  appear.  It  takes  approximately  25  minutes  to 
install the 4‐product suite indicated in No. 14 (page 9)onto a hard drive.  

   
   
Page 13 of 24 
 
 
26. When the installer has finished installing your chosen products, you will see the 
window  below.  Click  “Finish”.  Then  click  “Yes”  on  the  following  window  to 
restart your computer.  

 
   
Page 14 of 24 
 
27. If  at  any  time  during  the  course  of  installing  or  using  Aspen  Plus  you  receive 
either  of  the  following  error  dialogs,  simply  click  OK  and  continue  the 
installation.  After  the  installation  process  is  complete,  change  to  legacy 
databanks, or reinstall SQL Server Express using “Mixed Mode”.  

 
28. Upon  completion  of  the  installation,  restart  your  computer  as  prompted  by  the 
installer. 
   
Page 15 of 24 
 
29. You  are  now  ready  to  run  AspenPLUS  on  your  personal  computer.  From 
Windows,  go  to  “Start”,  “  All  Programs”,  “AspenTech”,  “Process  Modeling 
V7.3”, “AspenPlus”, then click on “AspenPlus User Interface” 

.   
30. The first time you run the software, you must select the server type. Choose local 
PC and save as the default connection.  

 
Page 16 of 24 
 
31. The first time you run the software, you must register as an academic user. 

 
32. You  will  be  see  the  Aspen  Start  up  window,  which  gives  you  the  options  of 
opening  a  blank  simulation,  a  template,  an  existing  simulation,  etc.  Select  one 
option and click “OK”.  

 
Page 17 of 24 
 
33. You can now run your simulation.  
 

 
   
Page 18 of 24 
 
Installing Heat Exchanger Design and Rating Tools.  
34. To  install  heat  exchanger  design  and  rating  tools,  select  “Aspen  Engineering 
(Upgrade) and click “Install”.  

 
35. Click “Next” when you see this window.  
Page 19 of 24 
 

 
36. Accept the license agreement.  

 
37. Select “Standard Install”.  
Page 20 of 24 
 
Page 21 of 24 
 
38. Select both products in the window below and click “Next”.  

 
39. Click “Install” at the window below.  

 
Page 22 of 24 
 
40. The  installation  dialog  box  will  appear.  It  takes  approximately  16  minutes  to 
install the 2‐product suite indicated in No. 38 (page 21) onto a hard drive.  

 
41. Click “Finish” at the window below.  

 
Page 23 of 24 
 
42. The  economic  evaluation  tools  and  the  heat  exchanger  design  and  rating 
program can be accessed from the Start Menu as indicated below.  

 
43. You may now use these tools.  

 
Page 24 of 24 
 
Removing the “Databanks Connection” error.  
1BU

After  installing Aspen, but  prior  to running Aspen Plus, change to legacy  databanks. 


From  Windows,  go  to  “Start”,  “  All  Programs”,  “AspenTech”,  “Process  Modeling 
V7.2”, “AspenPlus”, then click on “Aspen Properties Database Selector” 

 
44. Select the ”Legacy Properties Databanks”, then click OK.  

 
45. You can then run Aspen Plus without receiving a databank connection error.  
HU UH

46. Return to start of installation instructions or error dialog.  