You are on page 1of 112

Menvier Fire Systems

ONE COOPER
Every day, thousands of people all over the world use products made by Cooper

Industries. As a premier global manufacturing company, we believe that great brands are

built on high quality and excellent service. Which is why our brands have earned leading

positions in the markets we serve. Cooper Safety specialises in products designed to save

lives and protect property in commercial, industrial and residential buildings. It’s just one

of the seven divisions that continue to uphold our reputation through unparalleled sales

support and customer service.

2
Conventional Intelligent Addressable Ancillaries and Test Equipment
5 Conventional Contents 47 Intelligent Addressable Contents 103 Heavy Duty Relay Unit
7 Fire Panels 49 Fire Panels 105 Power Supply Unit
15 Detectors 61 Repeater Panels 107 Loop Tester Kit
17 Standard Base 65 Sensors 108 Addressable Device Programmer
19 Relay Base 67 Standard Base
21 Remote Indicator 69 Sounder Base
23 Reflective Beam Detectors 71 Sounder Beacon Base
25 Callpoints 73 Loop Connected Remote Indicator
27 Bells 75 Reflective Beam Detectors
29 Flush Sounders 77 Callpoints
31 Sounder and Sounder Beacon 79 Wall Sounders
33 Surface Sounders 81 Wall Sounder Beacons
37 Xenon Beacons 83 LED Beacons
41 LED Beacons 85 Interfaces
45 Door Retainers 97 Micro Interfaces

3
About us

ensure they are all fully compatible with


ERTI
N C F

Cooper Safety Fire Systems IO I


C
T

AT
PREVEN

LPCB
ION BO

each other and will function as a truly


S

A
S

R
LO D

Cooper Fire offers a comprehensive range integrated fire detection and alarm system.
of Menvier fire detection products suitable
for a wide range of projects, from a small It is absolutely vital that all the elements of
simple installation to a large complex multi a fire detection system are fully compatible
building site. with each other. To support this
philosophy, a large multi-disciplined
Cooper Fire manufacture a wide range of research and development team is based
products and offers complete fire in the UK at the Cooper Doncaster facility,
solutions, not just individual components. responsible for the integration of the very
A complete system can be specified from latest technology into the design of our
a single source, confident in the comprehensive range of fire products.
knowledge that all the components have
been specifically designed and tested to

4
Conventional Product Range

Conventional Contents
Page 7 Page 31
Control Panels Sounder
MF9300 and Sounder Beacon
MDS824 and MDS824B

Page 11 Page 33
Control Panels Surface Sounders
MF200 and MF400 MWS424SB and MWS424DB

Page 15 Page 35
Detectors Low Current Sounder
MPD821, MPT951, MFR830 MLC624
MMT860 and MHT890

Page 17 Page 37
Standard Base Xenon Beacons
MDB800 MXB124SB and MXB124DB

Page 19 Page 39
Relay Base Xenon Sounder Beacons
MDB800R MCD524SB and MCD524DB

Page 21 Page 41
Remote Indicator LED Beacons
CIR301 MLB124SB and MLB124DB

Page 23 Page 43
Reflective Beam Detectors LED Sounder Beacon
MBD50R and MBD100R MSB124SB and MSB124DB

Page 25 Page 45
Callpoints Heavy Duty Door Retainers
MBG914 and MBG917 MDR240 and MDR25L

Page 27
Bells
MBM246. MBM248 and
MWB824

Page 29
Flush Sounders
MFS324 and MFS324W

5
Conventional System Architecture
The philosophy of a conventional system revolves This increases installation complexity by forcing the
around dividing the building into a number of areas sounder wiring to follow different routes to that of the
called zones. The detectors and callpoints within detector wiring.
each zone are then wired on dedicated circuits. In the
event of a detector or callpoint being triggered, When designing a conventional system it is important
the panel is able to identify which circuit contains the to ensure that the panel has adequate zone capacity
triggered device and thereby indicate which zone the for the size and complexity of the building and that
fire alarm has come from. the panel can support the intended sounder circuit
wiring and loading.
It is then necessary to manually search the indicated
zone to pinpoint the exact cause of the fire alarm.

Zone 1 Zone 2
Unwanted Alarms
Because most conventional detectors are simple two
state devices they can only be in either a normal or
fire condition. Although modern components and
good system design can go some way to reducing
potential problems, it is not uncommon for
conventional systems to generate unwanted alarms
due to certain operating conditions or transient
environmental conditions such as the presence of
steam near to a smoke detector.

A key development aimed at reducing such unwanted


alarms has been the multi-criteria detector.
Traditionally, detectors were designed to respond to
particular fire phenomena such as heat or the
presence of smoke. However, Cooper now offer
multi-criteria devices, which contain both a smoke
sensing element and a thermal sensing element.

The fire alarm decision is taken by analysis of the


responses from both elements, resulting in improved
detection performance as well as greatly enhanced
false alarm suppression.

Sounder Circuits
In addition to the detection circuits, there is also a
need for separate circuits of alarm annunciation
devices such as sounders and beacons to signal the
existence of a fire alarm condition to the building
users. For sounder circuit continuity monitoring to
function effectively, sounder circuits have to be wired
in a single radial circuit, spurs and tees are not
permitted. Zone 3 Zone 4

Almost every conventional fire panel will have


facilities for more than one sounder circuit and
generally the higher the specification of the panel or
the higher the number of detection zones provided,
the more sounder circuits will be provided.

Normally however there will be less sounder circuits


than detection zone circuits so it will be necessary for
a sounder circuit to provide cover for more than one
zone.

6
Conventional Product Range

MF9300 Range Control Panel

simple access to connection terminals and batteries

MF9304 control panel

Overview Features
The Menvier MF9300 is a range of high specification • 2, 4, 8 or 16 zone panels
conventional control panels designed for a wide • Matching repeaters available
for 4, 8 and 16 zone panels
range of building types and sizes at a competitive
• Coincidence detection and
price. non-latching zone features on
4, 8 and 16 zone panels
Available in a choice of 2, 4, 8 or 16 zone versions, the • Surface or flush mounting
MFR9300 repeater panel MF9300 range is designed for ease of installation and option as standard
simple operation. • Up to 32 detectors per zone
• 72 hour standby as standard
All panels can be either surface or flush mounted, • 24 hour standby available
without the need of additional bezels or back boxes.

System flexibility is emphasised by the availability of Benefits


matching repeater panels for the 4, 8 and 16 zone
panels. • Designed for ease of installation
• One man walk test facility
• Fully compatible with Menvier
range of ancillaries

7
Conventional Control Panel - MF9300 Range

Technical Specification
Code MF9302 MF9304 MF9308 MF9316
Description 2 zone control panel 4 zone control panel 8 zone control panel 16 zone control panel
Standards EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998 EN54 Pt2 & Pt4 1998
EN50130-4:1996 EN50130-4:1996 EN50130-4:1996 EN50130-4:1996
EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994 EN500081-1:1992 & EN61000-2-2:1994
Specification
Number of Zones 2 4 8 16
Detectors per Zone 32 32 32 32
Number of Alarm Circuits 2 2 4 4
Alarm Circuit Load 500mA per circuit. 1A total 500mA per circuit. 1A total 500mA per circuit. 2A total 500mA per circuit. 2A total
End of Line Devices Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor Detection circuits: 12KΩ resistor
Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor Alarm lines: 12KΩ resistor
Auxiliary Fire Signal Output 1A 24V dc (resistive) single pole 1A 2 4V dc (resistive) single pole 1A 24V dc (resistive) single pole 1A 24V dc (resistive) single pole
changeover contacts. Isolate facility available changeover contacts. Isolate facility available changeover contacts. Isolate facility available changeover contacts. Isolate facility available
Auxiliary Fault Output N/A 1A 2 4V dc (resistive) single pole 1A 24V dc (resistive) single pole 1A 24V dc (resistive) single pole
changeover contacts changeover contacts changeover contacts
Auxiliary Common Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA
Auxiliary dc Output 24V dc fused. 100mA 24V dc fused. 100mA 24V dc fused. 350mA 24V dc fused. 350mA
Repeater output N/A 2 wire serial link 2 wire serial link 2 wire serial link
(repeater also requires separate 230V ac supply) (repeater also requires separate 230V ac supply) (repeater also requires separate 230V ac supply)
Mains Input Voltage 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz 230V ac ±10%. 50/60Hz
System Operating Voltage 24V dc 24V dc 24V dc 24V dc
Standby Duration 72 hours 72 hours 72 hours (24 hours option) 72 hours (24 hours option)
Battery 2 x 7Ah sealed lead acid battery 2 x 7Ah sealed lead acid battery 2 x 12Ah sealed lead acid battery 2 x 12Ah sealed lead acid battery
Recharge Period 24 hours 24 hours 24 hours 24 hours
Environmental
Operating Temperature -5°C to +40°C -5°C to +40°C -5°C to +40°C -5°C to +40°C
Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH 0 to 75% RH
Physical
Construction ABS/Polycarbonate housing & back box ABS/Polycarbonate housing & back box ABS/Polycarbonate housing & steel back box ABS/Polycarbonate housing & steel back box
Dimensions (H x W x D) 344mm x 395mm x 95mm 344mm x 395mm x 114mm 386mm x 395mm x 114mm 386mm x 395mm x 114mm
Weight 10.6kg 10.6kg 16.8kg (24 hours option 16.0kg) 16.9kg (24 hours option 16.0kg)
Ingress Protection IP20 IP20 IP20 IP20
Cable entries Top: 13 x 20mm knockouts Top: 13 x 20mm knockouts Top: 27 x 20mm knockouts Top: 27 x 20mm knockouts
Back: 1 x 20mm knockout Back: 1 x 20mm knockout Back: 1 x 20mm knockout Back: 1 x 20mm knockout

Note: If a repeater panel is required to operate Dimensions Description H (mm) W (mm) D1 (mm) D2 (mm)
with the MF9304, use the MFR9308, 8 zone MF9302 344 395 25 70
repeater. D1 MF9304 344 395 25 70
W
D2 MF9308 386 395 25 119
MF9316 386 395 25 119
MFR9308 386 395 25 119
MFR9316 386 395 25 119
H
Description Cut-out (mm)
MF9302 324 x 385
MF9304 324 x 385
MF9308 376 x 385
MF9316 376 x 385
Note: If surface mounting add D1 and D2 to obtain
depth dimension.

Product Codes
Code Description
MF9302 Conventional 2 zone control panel
MF9304 Conventional 4 zone control panel
MF9308 Conventional 8 zone control panel
MF9316 Conventional 16 zone control panel
MF9308L Conventional 8 zone control panel (24 hour standby)
MF9316L Conventional 16 zone control panel (24 hour standby)
MFR9308 Conventional 8 zone repeater panel
MFR9316 Conventional 16 zone repeater panel
MFALOG Fire alarm system log book

8
Conventional Control Panel - MF9300 Range

one zone (except 2 zone panel). An alarm condition


Installation is dependant upon a fire signal from 2 detectors Repeater Panels
1. A full set of installation and user instructions is within a defined period, when facility is selected. A 1. Repeaters match the style and
supplied with each panel to assist the installer to single detector fire signal is indicated by sounding appearance of main control
carry out the work efficiently and safely, and the the integral buzzer and flashing LED on the panel. panels.
end user to perform routine tests. Any fire signal from a manual callpoint on the zone 2. Facility for signalling to
2. Panels are designed to be wall mounted. When immediately operates the alarm. repeater panels provided on all
surface fixed use keyhole slot mounting holes 7. An alarm line delay feature can be selected (except main panels (except 2 zone).
found on back of housing, if recessed mounted 2 zone panel). Preset delays of 1 to 7 minutes can 3. Displays essential information
use an appropriate cut-out for panel and fixed via be programmed during commissioning, at other key locations in a large
6 x screw fixing holes around the housing flange. permanently illuminating a panel indicator when building/site.
3. Mains power supply cable must be routed via the set. Indicator and zone LED flash when fire signal • Zone fire or fault conditions
designated 20mm conduit entry knockouts on the is received and delay is in operation. Any fire signal • Zones or alarm lines in test
top or rear of the housing. The mains terminal from a manual callpoint immediately operates the mode
block is provided with fuse protection. alarm. • Zones or alarm lines in
4. Conduit entry knockouts are provided on the top of disabled mode
the housing for zone, alarm and output cables. A User Interface • Alarm delays
total of 13 (2/4 zone) or 27 (8/16 zone) knockouts • Faults, isolations and test
are provided. 1. Stylish and attractive panel with easy to use 8 mode for control outputs
5. Standby batteries are connected via push-on button keypad to control all functions. 4. Repeater panel requires only a
terminal connectors. 2. Comprehensive power, fire and fault LED single pair of wires to receive
6. End of line (EOL) devices are supplied with the indicators and integral piezo buzzer for on-board signals from main control
panel and must be fitted at the end of each fire or fault indication. panel, plus local mains power
detector and alarm circuit wiring. 3. Panel can be surface mounted or recessed, supply, reducing cost of
7. Front cover is screw fixed with hinged battery without the need of an additional fixing bezel or installation.
compartment door and hinged upper door for back box.
access to zone/alarm connections and 4. Special tool used to release hinged upper door to
configuration settings, which requires use of a access connections and configuration settings or
special tool for access. bottom door to access battery.

System Functionality Interface Options


1. Normal and supervisor mode facility. Supervisor 1. Class change input facility. Terminals provided for
mode protected by 4 digit security code to prevent switching of alarm circuits to indicate
unauthorised use. Service engineer and school/college class change.
configuration modes accessed by further security 2. Auxiliary 1A 24V dc fault relay (except 2 zone
codes. panel).
2. Supervisor mode provides access to test mode, 3. Remote signal 1A 24V dc relay for remote
where zones can be tested individually or in any location signalling, or operation of a remote dialler
combination. (can be isolated during tests/servicing).
3. One man walk test feature permits each manual 4. 24V dc common output provided (does not
callpoint and detector on the zone(s) in test mode operate with non-latching zone).
to be put into fire condition and activates the 5. Auxiliary 24V dc output power supply provided as
alarms for 2 seconds. Panel automatically resets standard.
the zone(s) 10 seconds after each device has been
tested. A fire condition received from a zone not in
test mode results in an immediate alarm, overriding Detection Capacity
the test mode. 1. Up to 32 detectors per zone. End of line
4. Supervisor mode also provides facility to monitoring devices must be fitted and are supplied
disable/isolate the following for maintenance or as standard.
other purposes 2. Detector circuits are monitored for open circuit,
• each detection zone independently short circuit and detector removal.
• the alarm circuits
• the remote signal output (except 2 zone panel)
5. Non-latching zone facility can be selected on one Alarm Capacity
zone, enabling the direct interconnection of panels
in a simple network. 1. 2 separate alarm lines on 2 and 4 zone panels.
6. Coincidence detection facility can be selected on 500 mA maximum load per line.
2. 4 separate alarm lines on 8 and 16 zone panels.
500mA maximum load per line.
3. Alarm lines are monitored for open circuit and
short circuit faults.

9
Conventional Control Panel - MF9300 Range

Standard Panel Connections

END OF LINE
12K RESISTOR TO DOOR RELEASE UNITS

MDB800 NC NC
DETECTOR MAR724 -
BASE HEAVY 24V dc 10mA COIL
DUTY
END OF LINE RELAY +
12K RESISTOR
C C

WITH ISOLATING FACILITY


+

TO REPEATER PANEL
- VE + VE

REQUIRING RELAY
TO APPLICATIONS
IN & OUT IN & OUT 230V ac +/- 10% 50/60Hz
ON 2 ON 1

TO VOLT FREE
+

CONTACTS

(NOTE 3)
MBG914/917

FAULT
CALLPOINT
connect as per (NOTE 1) +
instructions
subsequent alarm lines
subsequent zones

- + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + NC C NO NC C NO - + - +

EARTH

AUXILIARY 24V DC OUTPUT


AUXILIARY COMMON OUTPUT (NOTE 2)
CLASS CHANGE
REPEATER GROUND
REPEATER TRANSMIT
ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ALARM ALARM ALARM ALARM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4

FAULT REMOTE
RELAY SIGNAL
RELAY
NOTES:
1. All sounders must be polarised and suppressed.
2. Connection details for door release units when required.
3. Connection details for repeater panels when required.

10
Conventional Product Range

MF200 and MF400 Range Control Panels

MAR424 remote fire and fault relay PCB

MF200 control panel

Overview Features
The Menvier MF200 and MF400 range of • 2 or 4 zone panels
conventional control panels offer a competitive • Competitively priced
• Supplied complete with battery
solution for smaller installations.
and end of line devices

Easy to install and operate, the panels are designed


to provide fire detection and alarm facilities in Benefits
MAR424 fits inside MF200 and MF400 panels buildings where the basic elements of protection to
meet BS5839 are required. • Simple end user operation
• One man walk test facility
Available as either a 2 zone or 4 zone panel with up • Fully compatible with Menvier
to 20 detectors per zone can be connected. range of ancillaries

This range of Menvier control panels are conveniently


supplied complete with end of line devices and
batteries offering 24 hours standby as standard, with
the option of 72 hours on the 4 zone version.

One man walk test and class change facilities,


along with 24V dc remote signalling fire and fault
outputs augment a value for money range.

11
Conventional Control Panels - MF200 and MF400

Technical Specification
Code MF200 MF400
Description 2 zone control panel 4 zone control panel
Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996
Specification
Number of Zones 2 4
Detectors per Zone 20 20
Number of Alarm Lines 2 2
Alarm Circuit Load 375mA per circuit. 750mA total 375mA per circuit. 750mA total
End of Line Devices Detection circuits: 22KΩ resistor Detection circuits: 22KΩ resistor
Alarm lines: 22KΩ resistor Alarm lines: 22KΩ resistor
Auxiliary Fire Signal Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA
Auxiliary Fault Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA
Auxiliary dc Output 24V dc fused. 32mA 24V dc fused. 32mA
(up to 100mA at the expense of alarm load) (up to 100mA at the expense of alarm load)
Mains Input Voltage 240V ac +10%-15% 240V ac +10%-15%
System Operating Voltage 24V dc 24V dc
Standby Duration 24 hours 24 hours (72 hours on MF400-72)
Battery 1 x 4Ah sealed lead acid battery 1 x 4Ah sealed lead acid battery
(1 x 7Ah on MF400-72)
Recharge Period 48 hours (80% in 24 hours) 48 hours (80% in 24 hours)
Environmental
Operating Temperature -5°C to +40°C -5°C to +40°C
Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH
Physical
Construction ABS/Polycarbonate housing. Steel back box. ABS/Polycarbonate housing. Steel back box.
Dimensions (H x W x D) 300mm x 300mm x 74mm 300mm x 300mm x 74mm
Weight 4.8kg 4.8kg (6.0kg on MF400-72)
Ingress Protection IP30 IP30
Cable entries Top: 10 x 20mm conduit entries Top: 10 x 20mm conduit entries
Bottom: 1 x 20mm conduit entry (mains cable) Bottom: 1 x 20mm conduit entry (mains cable)
Back: 1 x mains cable entry slot Back: 1 x mains cable entry slot

Dimensions
D W
H (mm) W (mm) D (mm)
300 300 74

Product Codes
Code Description
MF200 Conventional 2 zone control panel
MF400 Conventional 4 zone control panel
MF400-72 Conventional 4 zone control panel (72 hour standby)
MAR424 Conventional fire and fault relay PCB
MFALOG Fire alarm system log book

12
Conventional Control Panels - MF200 and MF400

Installation User Interface


1. A full set of Installation and user Instructions is 1. Attractive compact panel with easy to use 5 button
supplied with each panel to assist the installer to keyboard to control all functions
carry out the work efficiently and safely, and the 2. Comprehensive power, fire and fault LED indicators
user to perform routine tests. and integral piezo buzzer for on-board fire or fault
2. Panels are wall mounted via keyhole slot mounting indication
holes on back of housing.
3. Mains power supply cable must be routed via the
designated 20mm conduit entry on the top or Interface Options
bottom of the housing, or via the rear cable entry 1. Class change input facility. Terminals provided for
slot. The mains terminal block is provided with fuse switching of alarm circuits to indicate
protection. school/college class change.
4. A total of 10 x 20mm conduit entries are provided 2. 24V dc outputs provided for remote signalling of
on the top of the housing for zone, alarm and fire and fault conditions.
output cables. Blanking plugs are supplied for un- 3. Optional relay board available (MAR424) to convert
used entries. fire and fault signals to volt free change over rated
5. Standby battery connected via push-on terminal at 24V dc, 1A dc.
connectors. 4. Auxiliary 24V dc output power supply provided as
6. End of line (EOL) devices are supplied with the standard.
panel and must be fitted at the end of each
detector and alarm circuit wiring.
7. Front cover retained by anti-tamper screws. Detection Capacity
1. Up to 20 detectors per zone. End of line monitoring
System Functionality devices must be fitted and are supplied as
standard.
1. Normal and supervisor mode facility. Supervisor 2. Detector circuits are monitored for open circuit,
mode protected by 4 digit security code to prevent short circuit and detector removal.
unauthorised use.
2. Supervisor mode provides access to test mode,
where zones can be tested individually. Alarm Capacity
3. One man walk test feature permits each manual
callpoint and detector on the zone in test mode 1. Two separate alarm lines, each with a maximum
to be put into fire condition and activates the rated load of 375mA.
alarms for 2 seconds. Panel automatically resets 2. Alarm lines are monitored for open circuit and short
the zone 10 seconds after each device has been circuit faults.
tested. A fire condition received from a zone not in
test mode results in an immediate alarm, overriding
the test mode.
4. Supervisor mode also provides facility to
disable/isolate the following for maintenance or
other purposes
• each detection zone independently
• the alarm circuits
• the remote signal outputs

13
Conventional Control Panels - MF200 and MF400

Standard Panel Connections

SWITCH /CONTACTOR/TIMER
24V dc 10mA DOOR RELEASE UNITS
END OF LINE PULL TO 0V RELAY OUTPUTS
22KOhm RESISTOR 240V dc 10A

(APPLY NO VOLTAGE)
MDB800
NC C NO NO C NC
DETECTOR
MAR724
BASE

FIRE SIGNAL
+ -

ISOLATING

24V dc AUXILARY SUPPORT


24V

SIGNAL
FAULT
10mA
END OF LINE COIL
22KOhm RESISTOR

+ VE - VE + - E + - E
IN & OUT IN & OUT AUX FAULT / AUX FAULT /
MAR724 REMOTE SIGNAL REMOTE SIGNAL
ON 1 ON 2
MAR424
24V 10mA
AUX RELAY OUTPUTS REMOTE
FAULT 24V 1A (resistive) SIGNAL
MBG914/917
CALLPOINT
C NC NO E E C NC NO
connect as per
instuctions subsequent subsequent MAR424
zones alarm lines + - E + -
24V 24V
10mA 10mA
COIL COIL
+ - E + - E + - E + - E + - E + - E + - E + - E + - E + - E + - E + - E
ZONE ZONE ZONE ZONE ALARM ALARM AUX REM CLASS AUX AUX REMOTE
1 2 3* 4* 1 2 FAULT SIG CHANGE DC FAULT SIGNAL

* MF400 ONLY
C = COMMON
NC = NOT NORMALLY CONNECTED
NO = NORMALLY OPEN

14
Conventional Product Range

Detectors

optical / photo-thermal / heat detectors

Overview Features
The Menvier range of conventional detectors • Quick and simple to install
have been specifically designed to operate with • Stylish low profile design
• 360º viewable LED
Menvier control panels.
• Removable detector chamber
• Drift compensation
The Menvier optical detector MPD821 is suitable for
most applications giving the fastest response to slow
burning or smouldering fires which give rise to large Benefits
visible smoke particles.
• ‘Clean me’ feature means
The Menvier photo-thermal detector MPT951 will detector can be cleaned on
innovative light pipe technology allows LED to be site using the Menvier manual
seen from any angle respond quickly to fast clean burning fires yet
maintain the advantage of optical detectors when cleaning procedure
detecting smouldering fires. The thermal • Common mounting base
enhancement of this detector allows a higher alarm • Positive ‘lock’ indication
threshold which provides a greater rejection of false
alarms. The detector will also raise an alarm at
temperatures exceeding 60ºC.

The Menvier fixed heat detectors MMT860 and


MHT890 will detect temperatures above 77ºC and
92ºC. The rate of rise heat detector MFR830 is used
to detect rapid increases in temperature with a
maximum threshold of 60ºC.

These detectors are designed to be used in


environments where the ambient conditions might
cause false alarms if smoke detection were to be
used, for example where there is a high level of dust,
fumes, steam or smoke under normal conditions.

15
Conventional Detectors

Technical Specification
Code MPD821 MPT951 MFR830 MMT860 MHT890
Description Optical smoke Detector Photo-thermal detector Rate of rise detector Fixed heat detector (77ºC) Fixed heat detector (92ºC)
Standards EN54 Pt7 2000, A1 2002 EN54 Pt 5 & Pt 7 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002
Supply Ratings
Operating Voltage 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc
Standby Current 30µA (max) 30μA (max) 30μA (max) 30μA (max) 30μA (max)
Startup Current 340µA (max) 340μA (max) N/A N/A N/A
Alarm Current 25mA (max) 25mA (max) 25mA (max) 25mA (max) 25mA (max)
Fixing Information
Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas
Mounting Options Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base
Area Coverage 100m² (subject to local standards) 100m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards)
System Wiring 2 Core 2 Core 2 Core 2 Core 2 Core
Operation
Detection Mode Light scatter principle Light scatter principle & Heat sensitive element Heat sensitive element Heat sensitive element
Heat sensitive element
Heat Class N/A A2S A2R BS CS
Alarm Temperature N/A 60ºC 60ºC 77ºC 92ºC
Indication 360º visible LED 360º visible LED 360º visible LED 360º visible LED 360º visible LED
Environmental
Operating Temperature -20ºC to 60ºC -20ºC to 45ºC -20ºC to 45ºC -20ºC to 60ºC -20ºC to 75ºC
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH
Physical
Construction PC/ABS PC/ABS PC/ABS PC/ABS PC/ABS
Colour White White White White White
Dimensions Excl Base (Dia x H) 101mm x 33mm 101mm x 43mm 100mm x 43mm 101mm x 43mm 101mm x 43mm
Dimensions Incl Base (Dia x H) 101mm x 45mm 101mm x 55mm 100mm x 55mm 101mm x 55mm 101mm x 55mm
Ingress Protection IP40 IP40 IP40 IP40 IP40
EMC CE Marked CE Marked CE Marked CE Marked CE Marked
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems

Dimensions Installation User Interface


1. Detectors are fixed and wired via common 1. Red LED to indicate alarm
Dia mounting base. condition.
2. Cable entry into base can be rear or side. 2. Amber LED to indicate
3. A locking facility is provided which can be chamber fault/drift
activated if required to prevent unauthorised compensation limit (enhanced
detector removal without the use of a special tool. versions only).
D
4. Positive click mechanism incorporated to provide 3. All wiring connections are via a
clear indication when detector is correctly located common mounting base
in base. (supplied separately).

Note: For wiring information please see


Description Dia (mm) D (mm) D (mm) MDB800 base.
(excl base) (incl base)
Optical 101 33 45
Photo-thermal 101 43 55
Heat 101 43 55

Product Codes
Code Description
MPD821 Conventional optical smoke detector
MPT951 Conventional photo-thermal detector
MFR830 Conventional rate of rise heat detector
MMT860 Conventional fixed heat detector (77°C)
MHT890 Conventional fixed heat detector (92°C)
MDB800 Conventional detector base
MDP201 Duct Probe

16
Conventional Product Range

Standard Base MDB800


Suitable detectors for use with
the MDB800 standard base

MPD821 optical detector

MDB800 standard base

Overview Features
MPT951 photo-thermal detector • Quick and simple to install
The MDB800 Menvier conventional base has been
specifically designed to be compatible with the • Separate zone in and zone out
terminals
Menvier range of conventional detectors.
• Stand off fixing feature
• Selectable detector locking
This standard base has been designed for flexibility,
simplicity and speed of installation.
Benefits
It incorporates purpose designed devices to provide
fault warning if detector is removed whilst • Accepts side entry surface
maintaining full zone wiring integrity. cables
• Common base for Menvier
The base has a spring contact switch and a parallel conventional detectors
zener diode to enable fault monitoring.

MFR830, MMT860, MHT890 heat detectors

17
Conventional Standard Base - MDB800

Dimensions Technical Specification


Dia (mm) D (mm) Code MDB800

104 22 Description Standard base


Physical
D Construction PC/ABS
Colour White
Dimensions (Dia x D) 104mm x 22mm
Compatibility
Suitable for use with Menvier conventional detectors
Dia

Installation Interface Options


1. Base incorporates a retaining clip to provide 1. Menvier conventional
positive feedback when detector is correctly fitted. detectors and bases support
2. Separate terminals are provided for zone in and the use of a remote LED
zone out connections. (optional extra CIR301).
3. Each terminal can accept up to 2 x 2.5mm cables
4. Base incorporates a substantial cable entry
aperture in the rear of the base.
5. Breakouts are provided to enable the detector
base to sit neatly over surface cables and then
enter via the rear entry aperture.
6. Base mounting incorporates a stand off feature to
help prevent distortion when mounted on an
uneven surface.
7. Fixings are suitable for standard BESA box or
direct fixing to suitable surface
8. Optional locking devices (supplied with base) to
prevent unauthorised detector removal.

Standard Connection
+ VE
+
remote indicator (optional)
Menvier Conventional

+ 1 LED
1 LED

end of line resistor


Control Panel

4
Compatible

4
ZONE

2 E 2 E

- 3 3

- VE

WARNING:
If using the outer connection on terminal 2, ensure the operation of the switch is not impeded
and that there are no shorts between terminal 2 and the switch contact - use sleeves for end
of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code Description
MDB800 Conventional standard base
MDB800*10 Conventional standard base (pack of 10)
CIR301 Conventional remote indicator

18
Conventional Product Range

Relay Base MDB800R


Suitable detectors for use with
the MDB800R relay base

MPD821 optical detector

MDB800R relay base

Overview Features
MPT951 photo-thermal detector • Quick and simple to install
The MDB800R Menvier conventional relay base has
been specifically designed to be compatible with • Designed specifically for use
with Menvier detectors
the Menvier range of conventional detectors.
• Provides remote signal for
external interfacing
This relay base as been designed for flexibility,
simplicity and speed of installation.
Benefits
It provides a local relay signal in the event of its host
detector being triggered, making it ideal for • First fix mounting plate for
instigating a local response. ease of installation
• Local control output from host
detector

MFR830, MMT860, MHT890 heat detectors

19
Conventional Relay Base - MDB800R

Dimensions Technical Specification


Code MDB800R
Dia (mm) D (mm) Description Relay base
102 40 Specification
Relay Contact Rating 1A at 24V dc
D
Relay Trigger Source Detector remote LED output
Detector Locking Facility Supplied as standard
Physical
Construction PC/ABS
Colour White
Dia
Dimensions (Dia x D) 102mm x 40mm
Compatibility
Suitable for use with Menvier conventional detectors

Installation Interface Options


1. Relay base is supplied with a first fix fixing plate. 1. Bases are compatible with
2. Fixing plate has a central cable aperture. latest generation conventional
3. Cable entry is from rear. Menvier detectors.
4. Main body is then clipped into place on base, body
locks into place when pressed into position.

System Functionality
1. Relay is controlled by status of host detector.
2. If host detector is triggered relay activates.

Standard Connection
+ VE
+
remote indicator (optional)

+
Menvier Conventional

LED
1 LED
1

end of line resistor


Control Panel

4 4
Compatible

ZONE

2 E 2 E

- 3 3

- VE

WARNING:
If using the outer connection on terminal 2, ensure the operation of the switch is not impeded
and that there are no shorts between terminal 2 and the switch contact - use sleeves for end
of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code Description
MDB800R Conventional relay base

20
Conventional Product Range

Remote Indicator CIR301

CIR301 remote indicator

Overview Features
The CIR301 conventional remote indicator is • Quick and simple to install
designed to provide discreet remote indication for • Wide viewing angle high
brightness LED
use with Menvier conventional detectors.
• Attractive styling

The remote indicator is ideal for applications such as


void spaces or outside locked or inaccessible rooms Benefits
to provide indication of the activation of an automatic
detector. • High profile LED
• Fits onto standard single gang
back box

21
Conventional Remote Indicator - CIR301

Dimensions Technical Specification


D
H (mm) W (mm) D (mm) Code CIR301

87 87 30 Description Remote indicator


Environmental
Operating Temperature -10°C to +55°C
H Humidity (Non Condensing) 0 to 95% RH
Physical
Construction ABS
Colour White
W Lens Colour Red
Dimensions (H x W x D) 87mm x 87mm x 30mm
Weight 0.28kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier conventional fire systems

Standard Connection Installation System Functionality


CIR301 1. Mounting plate fixes to single gang back box or 1. The remote indicator is
can be direct fixed to wall or ceiling. connected to an individual
2. Cable entry is normally from rear but breakouts are detector.
+ VE
+ provided in side of base plate. 2. The remote indicator activates
remote indicator (optional)
3. Cables connect to terminals on PCB within base if detector is triggered.
plate. 3. LED cancels when detector is
4. Front cover is pushed onto base plate and locks in reset.
Menvier Conventional

+ 1 LED
place. 4. Low current consumption.
Control Panel
Compatible

4
ZONE

2 E

- 3

- VE
IN

+ -
DETECTOR
BASE

Compatible
Menvier Conventional
Control Panel

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Terminal block unplugs


for ease of connection

Product Codes
Code Description
CIR301 Conventional remote indicator
M1R195B Conventional remote indicator (with buzzer)

22
Conventional Product Range

Reflective Beam Detectors MBD50R and MBD100R

optional mounting bracket with cable clamp facilities

MBD50R and MBD100R reflective beam detectors

Overview Features
The Menvier range of zone powered reflective beam • Quick and simple to install
detectors are specifically designed to be compatible • Simple two wire connection
• No power supply required
with the full range of conventional Menvier control
panels.
Benefits
Two versions are available, the MBD50R with a range
of up to 50 metres, and the MBD100R with a range of • Single device to install instead
combined transmitter and receiver for ease of of numerous point detectors
installation 50 - 100 metres.
• Single point of maintenance
Both of these units are extremely simple to install, they • Wall mounted for ease of
require no separate power supply, operate on a maintenance
reflective principle and have a simple set up mode to
enable easy and quick alignment during installation.

Beam detectors are designed to replace individual


point detectors in large open areas such as
warehouses.

Fire and fault conditions are signalled to panel using


standard zone wiring so no additional interconnection
is required.

In normal operation only one beam detector may be


connected per zone, however special versions are
available to work with external power supply if multiple
beam detectors are required to be connected to a
single zone.

23
Conventional Reflective Beam Detector - MBD50R and MBD100R

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MBD50R MBD100R

210 130 120 Description Reflective beam detector Reflective beam detector
Standards EN54 Pt 12 2002 EN54 Pt 12 2002
Specification
H D
Operating Voltage 18V dc to 30V dc 18V dc to 30V dc
Quiescent Current <5mA (no LED’s illuminated) <5mA (no LED’s illuminated)
Alarm Current <9mA <9mA
Alignment Current <18mA <18mA

W Power up Time 20 seconds (approx) 20 seconds (approx)


Operating Range 5 to 50 metres 50 to 100 metres
Tolerance to Beam
Misalignment at 35% Detector ± 0.8°, Prism ± 5.0° Detector ± 0.8°, Prism ± 5.0°
Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%)
Optical Wavelength 880nm 880nm
Environmental
Operating Temperature -10°C to +55°C -10°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Construction PC/ABS PC/ABS
Colour White White
Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm
Weight 0.8kg 0.8kg
Ingress Protection IP40 IP40
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation System Functionality


MBD50R / MBD100R 1. Must be fixed to solid structure. 1. Beam detectors have 3 modes
2. Recommended mounting height is 0.3 to 0.6 • Prism targeting mode
to beam detector socket
metres below the ceiling. designed to provide simple
3. Only 1 conventional reflective beam allowed per initial alignment of beam and
control panel zone, if multiple beams per zone reflector assembly.
IN

required, special externally powered version • Alignment mode


+ - + - available. Enables accurate fine tuning
4. Cables can be terminated into separate termination of beam alignment without
ZONE

Compatible
box (not supplied) or use purpose designed
IN

Menvier Conventional
Control Panel EOL
the need for additional
mounting bracket (MRBFP) ordered separately. calibration equipment or a
DEVICE
5. Mounting bracket has facilities for glanding of second operator.
incoming cables plus simple fixing of beam
• Normal running mode
WARNING: detector.
Do NOT use high voltage testers if ANY equipment is 6. Test filter is supplied with detector to simulate
connected to the system. required smoke obscuration level and confirm User Interface
correct operation.
Screen (Earth) must be continuous along entire length of zone.
1. Beam detector status LEDs
• Red LED
constantly illuminated
indicates fire condition.
• Flashing amber LED
indicates fault condition.

Interface Options
1. Conventional beam detectors
are connected directly to the
Menvier conventional panel.

Product Codes
Code Description
MBD50R Conventional reflective beam detector, 50m range
MBD100R Conventional reflective beam detector, 100m range
MRBFP Mounting bracket

24
Conventional Product Range

Callpoints MBG914 and MBG917

MBG917 weatherproof callpoint

MBG914 callpoint

Overview Features
This attractively designed, simple to install, range of • High visibility status LED
callpoints have been specifically developed to be • Standard and weatherproof
versions available
compatible with Menvier conventional fire panels.
• Wide range of accessories
• Heavy duty terminals
There are 2 versions of callpoint in this range. The
MBG914 which can be either surface or flush
MBGHCC protective hinged cover
mounted and the MBG917 which is a weatherproof Benefits
version.
• Quick and simple to install
All callpoints are supplied as standard with a • Fast fit clip on front cover
frangible glass element and a test key for ease of • Single tool for test and access
maintenance.

A comprehensive range of accessories are available


to maximise the functionality of the callpoint for
particular applications.

MBGBEZ recessing bezel

25
Conventional Callpoints - MBG914 and MBG917

Dimensions Technical Specification


W Code MBG914 MBG917
Description Surface/flush mount callpoint Weatherproof callpoint
Standards EN54 Pt11 EN54 Pt11
Specification
Operating Voltage 18V dc to 30V dc 18V dc to 30V dc
H
Environmental
Operating Temperature -10°C to +55°C -25°C to +70°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
D
Construction PC/ABS PC/ABS
Colour Red Red

Description H (mm) W (mm) D (mm) Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm
Weight 0.2kg 0.2kg
Flush mounted 87 87 36
Ingress Protection IP42 IP65
Surface mounted 87 87 57
Compatibility
Weatherproof 87 87 59
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Accessories


MBG914 / MBG917 1. Surface callpoint has standard rear BESA fixing • Semi recess bezel
facilities. In addition, back box can accept top or • Spacer plates
COMMON

bottom surface entry cables. Surface callpoint can • Hinged clear cover
also be flush mounted. • Resettable plastic element
470Ω

4V7

2. Callpoint has test facility via special test key to • Replacement test key
prevent unauthorised operation. • Replacement glass elements
+ + - - - - 3. Insertion of test key for test purposes and for cover • Earth continuity links
removal is at bottom of callpoint to facilitate ease
Compatible of access when mounted next to door architrave.
Menvier Conventional
Control Panel 4. Test key is dual function, used to test callpoint
operation by simulating activation and also to allow
removal of clip on cover to gain access to element.
WARNING: 5. Element is held in place by clip on self locking
Do NOT use high voltage testers if ANY equipment is
cover which can only be removed by use of a
connected to the system.
special tool (callpoint test key).
Screen (Earth) must be continuous along entire length of cable 6. Separate zone in and zone out terminals are
provided for all connections.
NOTE: 7. Surface/flush callpoints are IP42, weatherproof is
470Ω connection is for standard Menvier conventional panels. IP65.
4V7 connection can be used with MF9300 to enable certain
features on the Menvier MF9300 range of control panels.
User Interface
1. To enable quick and simple installation, callpoints
use a fast fit self locking clip on front cover which
is very simple to fit, but once in place, can only
be removed by use of a special key (supplied).
2. Callpoint is triggered by pressing against the
element.

Product Codes
Code Description
MBG914 Conventional surface/flush callpoint
MBG917 Conventional weatherproof callpoint
MBGHCC Protective hinged cover
MBGSP Spacer plates (pack of 10)
MBGBEZ Recessing bezels (pack of 10)
MBGREKIT Resettable element kit (pack of 10)
MBG118 Spare break glasses (pack of 5)
MBG119 Earth continuity links (pack of 5)
MFBGKEY3 Callpoint keys (pack of 10)

26
Conventional Product Range

Bells MBM246, MBM248 and MWB824

MWB824 weatherproof bell

MBM246 and MBM248 internal bells

Overview Features
Bells still remain a popular choice for many • Quick and simple to install
applications such as schools where they can • High sound output
• Low current consumption
sometimes be used as a signal for non fire
• Multi-fixing base plate (internal)
purposes such as class change. • IP42 rated (internal)
• IP54 rated (weatherproof)
MBM246 and MBM248
The MBM246 and MBM248 Menvier internal bells
incorporate highly efficient rotary centrifugal Benefits
movements combining high sound output with low • Can be used for non fire
current consumption. applications

MWB824
The MWB824 Menvier weatherproof bell enables a
common bell sound to be achieved throughout a
complete site, including areas where a weatherproof
device is required.

27
Conventional Bells - MBM246, MBM248 and MWB824

Dimensions Technical Specification


D Dia
Code MBM246 MBM248 MWB824
Description Internal 6 Inch bell Internal 8 Inch bell Weatherproof 8 Inch bell
Standards EN54 Pt3 EN54 Pt3 EN54 Pt3
Specification
Operating Voltage 24V dc 24V dc 24V dc
Dia
Current Consumption 25mA at 24V dc 28mA at 24V dc 28mA at 24V dc
Sound Output 93-95dB(A) at 24V dc 95-97dB(A) at 24V dc 95dB(A) (+/-2)
Environmental

D Operating Temperature -10°C to +55°C -10°C to +55°C -10°C to +55°C


Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH
Physical
Internal bell Weatherproof bell Construction gong - steel / base-polycarbonate gong - steel / base-polycarbonate stove enamelled
Colour Red Red Red
Dimensions (Dia x D) 152mm x 63mm 203mm x 67mm 200mm x 104mm
Description Dia (mm) D (mm) Weight 0.85kg 1.7kg 0.49kg
6 inch internal bell 152 63 Ingress Protection IP21C IP21C IP54
8 inch internal bell 203 67 Cable Entry Rear Rear Via separate back box

8 inch weatherproof bell 200 104 Compatibility


Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Device Functionality


MBM246 / MBM248 / MBM824 MBM246 / MBM248 MBM246 / MBM248
1. Multiple rear fixing options, can be fixed direct to 1. Sound output is fixed and
- - + + wall or mounted on suitable BESA box. determined by size of the bell.
2. Cable entry into bell is from rear. 2. Operation is driven by an
Compatible
Menvier Conventional 3. Incorporates heavy duty terminals suitable for internal motor and striker
Control Panel
2.5mm cables. arrangement.
3. Bells are polarised and
WARNING: MWB824 suppressed.
Do NOT use high voltage testers if ANY equipment is 1. Supplied with heavy duty gasketed back box
connected to the system. which supports bottom entry cables. MWB824
2. Incorporates heavy duty terminals. 1. Bell operates via solenoid.
Screen (Earth) must be continuous along entire length of cable 2. Bell is polarised and
suppressed.

Product Codes
Code Description
MBM246 Conventional internal 6 Inch bell
MBM248 Conventional internal 8 Inch bell
MWB824 Conventional weatherproof 8 Inch bell

28
Conventional Product Range

Flush Sounders MFS324 and MFS324W

MFS324W white flush sounder

MFS324 red flush sounder

Overview Features
The Menvier discreet flush sounder is designed to • Choice of colours
be compatible with Menvier conventional fire • Separate volume control
• Choice of tone is determined
systems. Available in a choice of colours MFS324
by selection of appropriate
red and MFS324W white. terminal for negative
connection
These flush sounders provide an excellent
combination of high sound output and discreet
appearance. Ideal for retail, hotel and residential Benefits
applications such as sheltered housing.
• Quick and simple to install
• Low profile design

29
Conventional Flush Sounder - MFS324 and MFS324W

Dimensions Technical Specification


W H (mm) W (mm) D (mm) Code MFS324 MFS324W
D Description Flush sounder Flush sounder
86 86 36
Standards EN54 Pt3 EN54 Pt3
Specification
Operating Voltage 6V dc to 28V dc 6V dc to 28V dc
H
Current Consumption 20mA at 24V dc 20mA at 24V dc
Sound Output 98dB(a) at 1 Metre (+/- 2) 98dB(a) at 1 Metre (+/- 2)
Environmental
Operating Temperature -25ºC to +55ºC -25ºC to +55ºC
Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH
Physical
Construction ABS ABS
Colour Red White
Dimensions (H x W x D) 86mm x 86mm x 36mm 86mm x 86mm x 36mm
Weight 0.3kg 0.3kg
Ingress Protection IP20 IP20
Cable Entry Via separate back box Via separate back box
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MFS324 / MFS324W 1. Sounder fixes to a single gang deep back box. 1. Operates from nominal 24V dc
2. Fixing screws included. supply and can be connected
2nd SOUND

3. Connections are to main sounder body. to any suitably rated


1st SOUND
COMMON

4. Separate loop in and loop out terminals are conventional sounder circuit.
provided.
5. For surface mount applications a separate red
single gang box can be ordered separately.
+ + - - - -
Compatible
Menvier Conventional
Control Panel

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:
Diagram shown with 1st sound connected, if 2nd sound is
required connect both negative in and negative out to the
second sound terminal.

Product Codes
Code Description
MFS324 Conventional flush sounder, red
MFS324W Conventional flush sounder, white
MFSSBB Back box, red

30
Conventional Product Range

Sounder and Sounder Beacon MDS824 and MDS824B

MDS824B sounder beacon with conventional


detector and base

MDS824 base mountable sounder

MDS824B sounder beacon with blanking plate Overview Features


(MDS824COV)
The Menvier base mountable sounder and sounder • Quick and simple to install
beacon have a slim and aesthetically pleasing • Low profile design
• Discreet appearance
design and can be installed as either as a discreet
• Blanking plate available when
stand alone sounder / sounder beacon or ceiling used as a stand alone sounder
mounted as shown, with detector and base.

When mounted with a detector and base it simplifies Benefits


the installation of the system by enabling a detector
• Single installation point
and sounder to be fixed at a single common point.
• Can be wired as a stand alone
unit
When used as a stand alone sounder the device can
be either wall or ceiling mounted and completed with
an optional cover plate (MDS824COV).

The sounder is ideal for applications such as hotel


bedrooms or where a detector sounder / sounder
beacon is required.

31
Sounder and Sounder Beacon - MDS824 and MDS824B

Dimensions Technical Specification


Dia
Dia (mm) D (mm) Code MDS824 MDS824B

111 26 Description Sounder Sounder beacon


Standards EN54 Pt3 EN54 Pt3
Specification
D
Operating Voltage 10V dc to 28V dc 10V dc to 28V dc
Current Consumption 5mA (low) 7 ma (high) at 24V 7mA (low) 10 ma (high) at 24V
Sound Output 80/90dB(a) (+/-3) @ 1 Metre 80/90dB(a) (+/-3) @ 1 Metre
Environmental
Operating Temperature -10°C to +55°C -10°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Construction ABS ABS
Colour White White
Dimensions (Dia x D) 111mm x 26mm 111mm x 26mm
Weight 0.4kg 0.4kg
Ingress Protection IP30 IP30
Cable Entry Rear Rear
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MDS824 / MDS824B 1. Sounder/beacon fixes to mounting surface. 1. Operates from nominal 24V dc
2. Cables pass through the middle of the sounder. supply and can be connected
2nd SOUND

3. Sounder/beacon wiring terminates at the sounder to any suitably rated


1st SOUND

COMMON

terminals. conventional sounder circuit.


4. Detector wiring terminates at normal connections
on detector base.
5. If no detector is to be fitted, a blanking plate can
- - - - + + be fitted instead.
Compatible
Menvier Conventional
Control Panel

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:
Diagram shown with 1st sound connected, if 2nd sound is
required connect both negative in and negative out to the
second sound terminal.

Product Codes
Code Description
MDS824 Conventional sounder
MDS824B Conventional sounder beacon
MDS824COV Blanking plate (pack of 5)

32
Conventional Product Range

Surface Sounders MWS424SB and MWS424DB

MWS424DB weatherproof surface sounder MWS424SB low profile surface sounder

Overview Features
These general purpose conventional surface MWS424SB
sounders have been specifically designed to work • Low profile design
with Menvier conventional control panels. • Pre drilled cable entries
• 32 selectable tones
MWS424SB
The MWS424SB is a low profile surface sounder. MWS424DB
• Weatherproof version (IP65)
Volume is adjustable via the internal volume control • Choice of cable entry positions
and 32 different alarm tone selections are provided. • 32 selectable tones
low profile base
Depending on the selected tone, sound levels of up Benefits
to 105dB(A) can be achieved.
• Low current, high sound
MWS424DB output
The MWS424DB is a weatherproof (IP65) surface • Suitable for a wide range of
sounder. applications
• Automatic synchronisation
Volume is adjustable via the internal volume control
and 32 different alarm tone selections are provided.

Depending on the selected tone, sound levels of up


to 105dB(A) can be achieved.

weatherproof base

33
Conventional Surface Sounders - MWS424SB and MWS424DB

Dimensions Technical Specification


D D Code MWS424SB MWS424DB
Description Low profile surface sounder Weatherproof surface sounder
Standards EN54 Pt3 EN54 Pt3
Specification
Operating Voltage 9V dc to 28V dc 9V dc to 28V dc
Current Consumption 16mA at 24V dc 16mA at 24V dc
Sound Output 105dB(a) max (+/-2) at 24V dc 105dB(a) max (+/-2) at 24V dc
Number of Tones 32 32

Dia Environmental
Dia

Operating Temperature -25°C to +70°C -25°C to +70°C


Low profile Weatherproof Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
surface sounder surface sounder Physical
Construction PC/ABS PC/ABS
Colour Red Red
Description Dia (mm) D (mm) Dimensions (Dia x D) 93mm x 63mm 93mm x 93mm
Low profile surface sounder 93 63 Weight 0.24kg 0.3kg
Weatherproof surface sounder 93 93 Ingress Protection IP54 IP65
Cable Entry Rear Rear/side
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MWS424SB / MWS424DB MWS424SB MWS424SB / MWS424DB
1. Supplied with simple to install first fix mounting 1. Operates from nominal 24V dc
2nd SOUND
1st SOUND

base. supply and can be connected


COMMON

2. Fixing and cable entry holes are pre-drilled. to any suitably rated
3. Cable entry is from rear. conventional sounder circuit.
4. Connections are to main sounder body.
5. Separate zone in and zone out terminals are
+ + - - - - provided. Options
Compatible
6. Main body is pushed into sounder base and then
MWS424SB / MWS424DB
Menvier Conventional twisted to lock into place.
Control Panel 1. Choice of tone setting (set via
DIP switches can be altered at
MWS424DB any time).
WARNING: 1. Supplied with simple to install first fix mounting
Do NOT use high voltage testers if ANY equipment is base.
connected to the system. 2. To maintain weatherproof integrity, fixing holes are
drilled upon installation.
Screen (Earth) must be continuous along entire length of cable
3. Cable entry can be rear or side.
NOTE: 4. Connections are to main sounder body.
Diagram shown with 1st sound connected, if 2nd sound is 5. Separate zone in and zone out terminals are
required connect both negative in and negative out to the provided.
second sound terminal. 6. Main sounder body is pushed into mounting base
and twisted to lock.

Product Codes
Code Description
MWS424SB Conventional low profile surface sounder
MWS424DB Conventional weatherproof surface sounder

34
Conventional Product Range

Low Current Sounder MLC624

MLC624 low current sounder

Overview Features
The MLC624 Menvier low current sounder has been • Quick and simple to install
designed to provide a high sound output with a low • Low current consumption
• High efficiency design
current consumption.
• 3 different tones
• Separate volume control
It is ideal for applications where high sound levels
need to be achieved but where available sounder
circuit capacity is limited. Benefits
The low current sounder is simple to install and uses • Low current, high sound
a first fix back plate onto which the main body output
attaches with a self locking press fix assembly. • Automatic synchronisation
• Self locking assembly

35
Conventional Low Current - MLC624

Dimensions Technical Specification


D
H (mm) W (mm) D (mm) Code MLC624

105 105 95 Description Low current sounder


Standards EN54 Pt3
Specification
Operating Voltage 12V dc to 30V dc
H

Current Consumption 5mA at 24V dc


Sound Output 100dB(a) at 24V dc
Environmental

W Operating Temperature -25°C to +70°C


Humidity (Non Condensing) 0 to 93% RH
Physical
Construction PC/ABS
Colour Red
Dimensions (H x W x D) 105mm x 105mm x 95mm
Weight 0.25kg
Ingress Protection IP42
Cable Entry Rear or top/bottom
Compatibility
Suitable for use with Menvier conventional fire systems

Standard Connection Installation Interface Options


MLC624 1. First fix mounting plate is fixed to wall. 1. Operates from nominal 24V dc
2. Cable entry is from rear, or top/bottom. supply and can be connected
2nd SOUND

3. Connections are to main sounder body. to any suitably rated


1st SOUND
COMMON

4. Separate alarm line in / out terminals are provided. conventional sounder circuit.

+ + - - - -
Compatible
Menvier Conventional
Control Panel

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Screen (Earth) must be continuous along entire length of cable

NOTE:
Diagram shown with 1st sound connected, if 2nd sound is
required connect both negative in and negative out to the
second sound terminal.

Product Codes
Code Description
MLC624 Conventional low current sounder

36
Conventional Product Range

Xenon Beacons MXB124SB and MXB124DB

MXB124DB weatherproof xenon beacon MXB124SB low profile xenon beacon

Overview Features
MXB124SB
This range of Menvier xenon beacons is available to • Unobtrusive low profile design
complement purely audible alarms for use in areas • High output xenon beacon
either where people may be present who have • Pre drilled cable entries
impaired hearing or areas with high ambient noise entry holes
levels.
MXB124DB
Xenon beacons have a high light output to maximise • Weatherproof version (IP65)
the attention attracting potential of the device. • High output xenon beacon
• Choice of cable entry positions
low profile base MXB124SB
The MXB124SB low profile xenon beacon features a Benefits
high performance light source. Pre-drilled fixing and
cable entry holes it is simple to install. • first fix base
• Compatible with range of
MXB124DB Menvier fire detection panels
The MXB124DB weatherproof xenon beacon is • Weatherproof version
IP65 rated and supports side entry surface cables
making it ideal for industrial applications.

Lower power LED variants are also available which


offer a lower current consumption but have a
consequently lower light output than traditional xenon
types (MLB124SB and MLB124DB LED beacons).

weatherproof base

37
Conventional Xenon Beacons - MXB124SB and MXB124DB

Dimensions Technical Specification


Code MXB124SB MXB124DB
Description Low profile xenon beacon Weatherproof xenon beacon
Specification
Operating Voltage 24V dc 24V dc
D D Current Consumption 45mA at 24V dc 45mA at 24V dc
Operation Continuous Continuous
Flash Energy 1.45J 1.45J
Flash Frequency 60 per minute 60 per minute
Dia
Environmental
Dia
Operating Temperature -20°C to +55°C -20°C to +55°C
Low profile Weatherproof Humidity (Non Condensing) 0 to 93% RH 0 to 93 RH
xenon beacon xenon beacon Physical
Construction PC/ABS PC/ABS
Colour Red Red
Description Dia (mm) D (mm) Lens Colour Red Red
Low profile xenon beacon 93 72 Dimensions (Dia x D) 93mm x 72mm 93mm x 101mm
Weatherproof xenon beacon 93 101 Weight 0.2kg 0.25kg
Ingress Protection IP54 IP65
Cable Entry Rear Rear/side
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MXB124SB / MXB124DB MXB124SB MXB124SB / MXB124DB
1. Supplied with simple to install first fix mounting 1. Operates from nominal 24V dc
+ + - - base. supply and can be connected
2. Fixing and cable entry holes are pre-drilled. to any suitably rated
Compatible
Menvier Conventional 3. Cable entry is from rear. conventional sounder circuit.
Control Panel
4. Connections are to main beacon body.
5. Separate alarm line in / out terminals are
WARNING: provided.
Do NOT use high voltage testers if ANY equipment is 6. Main body is pushed into sounder base and then
connected to the system. twisted to lock into place.

Screen (Earth) must be continuous along entire length of cable MXB124DB


1. Supplied with simple to install first fix mounting
base.
2. Cable entry is from rear or side.
3. Connections are to main beacon body.
4. Separate alarm line in / out terminals are
provided.
5. Main body is pushed into sounder base and then
twisted to lock into place.

Product Codes
Code Description
MXB124SB Conventional low profile xenon beacon, 1 Watt
MXB124DB Conventional weatherproof xenon beacon, 1 Watt
MXB224SB Conventional low profile xenon beacon, 2 Watt
MXB224DB Conventional weatherproof xenon beacon, 2 Watt

38
Conventional Product Range

Xenon Sounder Beacons MCD524SB and MCD524DB

MCD524DB weatherproof xenon sounder beacon MCD524SB low profile xenon sounder beacon

Overview Features
This range of Menvier xenon sounder beacons is MCD524SB
available to complement purely audible alarms for • Unobtrusive low profile design
use in areas either where people may be present • High output xenon beacon
• Pre drilled cable entries
who have impaired hearing or areas with high
• Sounder and beacon with a
ambient noise levels. single installation point
• 32 selectable tones
The key benefit of these devices is that an audible
and a visual alarm are combined together and require
MCD524DB
only a single installation point. This greatly reduces
• Weatherproof version (IP65)
low profile base installation time and cost and is much less obtrusive
• High output xenon beacon
than 2 separate devices. Xenon beacons have a high
• Side entry surface cables
light output to maximise the attention attracting
• Sounder and beacon with a
potential of the device.
single installation point
• 32 selectable tones
MCD524SB
The MCD524SB low profile xenon sounder beacon
features a high performance light source and Benefits
adjustable volume control. Due to predrilled fixing
and cable entry holes it is simple to install. • Combined audio / visual unit
• Single installation point
MCD524DB
The MCD524DB weatherproof xenon sounder
beacon is IP65 rated and features a high performance
light source and adjustable volume control.

weatherproof base Lower power LED variants are also available which
offer a lower current consumption but have a
consequently lower light output than traditional xenon
types (MSB124SB and MSB124DB LED sounder
beacons).

39
Conventional Xenon Sounder Beacons - MCD524SB and MCD524DB

Dimensions Technical Specification


D D Code MCD524SB MCD524DB
Description Low profile xenon sounder beacon Weatherproof xenon sounder beacon
Specification
Operating Voltage 18V dc to 30V dc 18V dc to 30V dc
Current Consumption 68mA (av) 73mA (peak) 68mA (av) 73mA (peak)
Operation Continuous Continuous
Flash Energy 0.7J 0.7J
Flash Frequency 60 per minute 60 per minute

Dia
Sound Output 101dB(a) max (+/-3) at 24V dc 101dB(a) max (+/-3) at 24V dc
Dia

Number of Tones 32 32
Low profile Weatherproof Environmental
xenon sounder beacon xenon sounder beacon Operating Temperature -20°C to +55°C -20°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Description Dia (mm) D (mm) Construction PC/ABS PC/ABS
Low profile Colour Red Red
xenon sounder beacon 93 92 Lens Colour Red Red

Weatherproof Dimensions (Dia x D) 93mm x 92mm 93mm x 121mm


Weight 0.25kg 0.33kg
xenon sounder beacon 93 121
Ingress Protection IP54 IP65
Cable Entry Rear Rear/side
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MCD524SB / MCD524DB MCD524SB MCD524SB / MCD524DB
1. Supplied with simple to install first fix mounting 1. Operates from nominal 24V dc
2nd SOUND

base. supply and can be connected


1st SOUND

COMMON

2. Fixing and cable entry holes are pre-drilled. to any suitably rated
3. Cable entry is from rear. conventional sounder circuit.
4. Connections are to main beacon body.
5. Separate alarm line in / out terminals are
- - - - + + provided.
Compatible
6. Main body is pushed into sounder base and then
Menvier Conventional twisted to lock into place.
Control Panel
7. Supply is common for sounder and beacon

WARNING: MCD524DB
Do NOT use high voltage testers if ANY equipment is 1. Cable entry is from rear or side.
connected to the system. 2. Connections are to main beacon body.
3. Separate alarm line in / out terminals are
Screen (Earth) must be continuous along entire length of cable
provided.
NOTE: 4. Main body is pushed into sounder base and then
Diagram shown with 1st sound connected, if 2nd sound is twisted to lock into place.
required connect both negative in and negative out to the 5. Supply is common for sounder and beacon
second sound terminal.

Product Codes
Code Description
MCD524SB Conventional low profile xenon sounder beacon
MCD524DB Conventional weatherproof xenon sounder beacon

40
Conventional Product Range

LED Beacons MLB124SB and MLB124DB

MLB124DB weatherproof LED beacon MLB124SB low profile LED beacon

Overview Features
This range of Menvier LED beacons is available to MLB124SB
complement audible alarms for use in areas either • Unobtrusive low profile design
where people may be present who have impaired • Low power consumption LED’s
• Choice of flash frequency
hearing or areas with high ambient noise levels.
• Choice of power settings
• Pre drilled cable entries
LED technology offers a greatly reduced current
consumption compared to xenon types making them
ideal for use with fire panels with restricted sounder MLB124DB
circuit current capacity. • Weatherproof version (IP65)
• Low power consumption LED’s
low profile base • Choice of flash frequency
MLB124SB
• Choice of power settings
The MLB124SB low profile LED beacon is simple to
• Choice of cable entry positions
install, and offers a reduced depth with pre-drilled
fixing and cable entry holes, suitable for both wall or
ceiling mounting. This beacon utilises 18 carefully Benefits
positioned LED's to provide a high intensity output.
Both output intensity and flash frequency is • Low power requirement
selectable using internal DIP switch. • Selectable flash frequency
• Selectable flash intensity
MLB124DB
The MLB124DB weatherproof LED beacon is IP65
rated making them ideal for industrial applications.
This beacon utilises 18 carefully positioned LED's to
provide a high intensity output. Both output intensity
and flash frequency is selectable using internal DIP
weatherproof base switch.

41
Conventional LED Beacons - MLB124SB and MLB124DB

Dimensions Technical Specification


Code MLB124SB MLB124DB
Description Low profile LED beacon Weatherproof LED beacon
Specification
Operating Voltage 18V dc to 30V dc 18V dc to 30V dc
D
D Current Consumption 3 to 6mA at 24V dc (depending on power setting) 3 to 6mA at 24V dc (depending on power setting)
Flash Frequency 30 or 60 per minute (selectable) 30 or 60 per minute (selectable)
Environmental
Operating Temperature -10°C to +55°C -10°C to +55°C
Dia Dia
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Low profile Weatherproof Construction PC/ABS PC/ABS
LED beacon LED beacon Colour Red Red
Lens Colour Red Red
Dimensions (Dia x D) 95mm x 53mm 95mm x 80mm
Description Dia (mm) D (mm) Weight 0.1kg 0.15kg
Low profile LED beacon 95 53 Ingress Protection IP54 IP65
Weatherproof LED beacon 95 80 Cable Entry Rear Rear/side
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MLB124SB / MLB124DB MLB124SB MLB124SB / MLB124DB
1. Supplied with simple to install first fix mounting 1. Operates from nominal 24V dc
+ + - - base. supply and can be connected
2. Fixing and cable entry holes are pre-drilled. to any suitably rated
Compatible
Menvier Conventional 3. Cable entry is from rear. conventional sounder circuit.
Control Panel
4. Connections are to main beacon body.
5. Separate alarm line in / out terminals are
WARNING: provided.
Do NOT use high voltage testers if ANY equipment is 6. Main body is pushed into base and then twisted to
connected to the system. lock into place.

Screen (Earth) must be continuous along entire length of cable MLB124DB


1. Supplied with simple to install first fix mounting
base.
2. Cable entry is from rear or side.
3. Connections are to main beacon body.
4. Separate alarm line in / out terminals are
provided.
5. Main body is pushed into base and then twisted to
lock into place.

Product Codes
Code Description
MLB124SB Conventional low profile LED beacon
MLB124DB Conventional weatherproof LED beacon

42
Conventional Product Range

LED Sounder Beacon MSB124SB and MSB124DB

MSB124DB weatherproof LED sounder beacon MSB124SB low profile LED sounder beacon

Overview Features
This range of Menvier LED sounder beacons is MSB124SB
available to complement purely audible alarms for • Unobtrusive low profile design
use in areas either where people may be present • Low current LED beacon
• Sounder and beacon with a
who have impaired hearing or areas with high
single installation point
ambient noise levels. • Pre-drilled fixing and cable
entry holes
LED technology offers a greatly reduced current • 32 selectable tones
consumption compared to xenon types making them
ideal for use with fire panels with restricted sounder
MSB124DB
low profile base circuit current capacity.
• Weatherproof version (IP65)
• Low current LED beacon
MSB124SB • Sounder and beacon with a
The MSB124SB low profile LED sounder beacon single installation point
features a low current LED light source and • Choice of cable entry positions
adjustable volume control. Choice of tones can be • 32 selectable tones
selected via the DIP switch. With predrilled fixing and
cable entry holes it is simple to install.
Benefits
MSB124DB
• Low power requirement
The MSB124DB weatherproof LED sounder beacon
• Adjustable sounder volume
is IP65 rated and features a low current LED light
• Selectable tones
source and adjustable volume control.

weatherproof base

43
Conventional LED Sounder Beacon - MSB124SB and MSB124DB

Dimensions Technical Specification


Dia Dia
Code MSB124SB MSB124DB
Description Low profile LED sounder beacon Weatherproof LED sounder beacon
Standards EN54 Pt3 EN54 Pt3
Specification
Operating Voltage 9V dc to 28V dc 9V dc to 28V dc
D D
Current Consumption 20mA at tone 3 20mA at tone 3
Operation Continuous Continuous
Flash Frequency 60 per minute 60 per minute
Number of Tones 32 32
Environmental
Low profile Weatherproof Operating Temperature -10°C to +55°C -10°C to +55°C
LED sounder beacon LED sounder beacon Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Construction PC/ABS PC/ABS
Description Dia (mm) D (mm) Colour Red Red
Low profile Lens Colour Red Red
LED sounder beacon 93 80 Dimensions (Dia x D) 93mm x 80mm 95mm x 109mm

Weatherproof Weight 0.25kg 0.3kg


Ingress Protection IP54 IP65
LED sounder beacon 95 109
Cable Entry Rear Rear/side
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation Interface Options


MSB124SB / MSB124DB MSB124SB MSB124SB / MSB124DB
1. Supplied with simple to install first fix mounting 1. Operates from nominal 24V dc
2nd SOUND
1st SOUND

base. supply and can be connected


COMMON

2. Fixing and cable entry holes are pre-drilled. to any suitably rated
3. Cable entry is from rear. conventional sounder circuit.
4. Connections are to main beacon body. .
5. Separate alarm line in / out terminals are
+ + - - - - provided.
Compatible
6. Main body is pushed into sounder base and then
Menvier Conventional twisted to lock into place.
Control Panel
7. Supply is common for sounder and beacon

WARNING: MSB124DB
Do NOT use high voltage testers if ANY equipment is 1. Cable entry is from rear or side.
connected to the system. 2. Connections are to main beacon body.
3. Separate alarm line in / out terminals are
Screen (Earth) must be continuous along entire length of cable
provided.
NOTE: 4. Main body is pushed into base and then twisted to
Diagram shown with 1st sound connected, if 2nd sound is lock into place.
required connect both negative in and negative out to the 5. Supply is common for sounder and beacon
second sound terminal.

Product Codes
Code Description
MSB124SB Conventional low profile LED sounder beacon
MSB124DB Conventional weatherproof LED sounder beacon

44
Conventional Product Range

Heavy Duty Door Retainers MDR240 and MDR24L

floor mounted heavy duty door retainer

wall mounted heavy duty door retainer

Overview Features
This range of Menvier heavy duty magnetic door • Heavy duty construction
door strike plate retainers are robust and simple to install, making • Mains and 24V dc version
• Manual release switch
them ideal for a wide range of applications, such as
• Optional floor mounting
nursing homes, hospitals, schools and industrial bracket available
premises.

Two versions are available, the mains powered Benefits


MDR240 which has a holding force of 40kg and the • Quick and simple to install
MDR24L 24V dc powered also with a holding force of • Slim profile unit
40kg

Both versions enable doors to be held open under


normal conditions but to be automatically released in
the event of fire alarm activation.

Their die cast aluminium construction with plastic


front cover plate make them suitable for most
applications.

Both versions are supplied with door mounted striker


plates and can be fixed directly to a suitable wall,
alternatively a floor bracket can be used to allow floor
mounting.

An override switch is fitted as standard to enable


door to be manually released as required.

45
Conventional Heavy Duty Door Retainers - MDR240 and MDR24L

Dimensions Technical Specification


Code MDR240 MDR24L
D W Description Mains powered heavy duty door retainer 24V dc powered heavy duty door retainer
W Specification

D Operating Voltage 230V ac to 240V ac 24V dc


Power Consumption 1.2VA 40mA
Holding Force 40kg 40kg
H
Environmental
H Operating Temperature -10°C to +55°C -10°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Construction PC/ABS PC/ABS

Description H (mm) W (mm) D (mm) Colour White body / black plate White body / black plate
Dimensions (H x W x D) Magnet: 95mm x 95mm 40mm Magnet: 95mm x 95mm 40mm
Magnet 95 95 40
Striker plate: 65mm x 65mm x 48mm Striker plate: 65mm x 65mm x 48mm
Striker Plate 65 65 48
Weight 1.0kg 1.0kg
Ingress Protection IP40 IP40
Compatibility
Suitable for use with Menvier conventional fire systems Menvier conventional fire systems

Standard Connection Installation System Functionality


MDR240 / MDR24L 1. Door retainer unit and striker plate should be fixed 1. Designed to operate only with
to a smooth surface. self closing doors.
INPUT VOLTAGE 2. A single 20mm cable entry facility is provided. 2. Door retainer is fitted to wall or
3. Door retainer can be rotated to provide cable entry floor using floor bracket.
at either top, bottom or side as required. 3. Striker plate is fitted to door.
4. Fixings should be able to support at least double 4. Door retainer is fed with a
the holding force of the magnet. constant supply via an external
control device.
5. Supply energises an
electromagnet, which holds
the striker plate securely
TO HEAVY DUTY DOOR MAGNET
against the magnet.
WARNING: 6. If supply to magnet is
Do NOT use high voltage testers if ANY equipment is interrupted, magnet de-
connected to the system. energises.
7. Door closes under control of
its own self closing device.

Product Codes
Code Description
MDR240 Conventional mains powered heavy duty magnetic door retainer
MDR24L Conventional 24V dc heavy duty magnetic door retainer
ZMDRFBB Floor mounting bracket for heavy duty door retainer

46
Intelligent Addressable Product Range

Intelligent Addressable Contents


Page 49 Page 77
Control Panels Callpoints
DF6100 MBG813 and MBG817

Page 55 Page 79
Control Panels Wall Sounders
DF6000 MAS850LPS and
MAS850LPSWP

Page 61 Page 81
Passive Repeater Panel Wall Sounder Beacons
DF6000PR MASB860 and MASB860WP

Page 63 Page 83
Touch Screen Repeater Panel Loop Connected LED Beacon
DTPR6000 MAB870

Page 65 Page 85
Sensors Interfaces
MAP820, MAOH850 and
MAH830

Page 67 Page 97
Standard Base Micro Interfaces
MAB800

Page 69 Page 103


Sounder Base Ancillaries and Test
MAS850 Equipment

Page 71
Sounder Beacon Base
MASB870

Page 73
Loop Connected
Remote Indicator
MRIAD

Page 75
Reflective Beam Detectors
MAB50R and MAB100R

47
Intelligent Addressable Product Range

Intelligent Addressable System Architecture


Standard conventional systems utilise simple two If whilst continually interrogating the smoke and heat
state detectors, which simply provide a switch type sensors, the panel determines that the data gathered
signal to the conventional control panel. from a specific device is appropriate to instigate
either a fire, fault or pre alarm condition, it uses the
To enable the source of the alarm to be identified, unique identifying number or address to determine
each zone must be wired using a separate circuit, which device is involved. Consequently the panel can
furthermore in the event of a fire alarm being pinpoint and identify precisely which device has
triggered, the panel can only identify which zone triggered the fire, fault or pre alarm condition.
contains the triggered device, it is then necessary to
manually search the affected zone to discover the This level of sophistication removes the need for each
actual cause of the alarm. zone of the building to be wired as a separate circuit.
For this reason intelligent addressable system
Intelligent addressable systems overcome these components are typically connected to the panel
limitations, each fire detecting sensor or callpoint is using a small number of large loops thus greatly
electronically coded with a unique identification or simplifying the installation of the system and reducing
'address' which is programmed into the device during the installation cost.
installation.
Detectors instead of being simple two state devices
The control panel is then able to conduct two way now function as sensors continually communicating
communication with any of the addressable devices with the control panel and providing information
connected to the system by using the unique address regarding the temperature or concentration of
number to define which device it wishes to smoke in their local environment.
communicate with. This operates in a similar manner
to that of a telephone number enabling
communication between specific telephones.
Zone 1 Zone 2
Under normal conditions the control panel
continuously interrogates each device in sequence
using a low power digitally pulsed
signal, and analyses the reply to determine the status
of the sensor or callpoint. 15 16 1 2

In this manner, the panel can ascertain whether each


device is functioning correctly and also discover the 14 3
amount of smoke or heat that the device is currently
sensing.

This technology allows the panel to make intelligent


decisions as to the appropriate action to take based 13 4
on the information it receives from the individual
sensors.

This has many advantages, for example very slow Mains Supply
build up of apparent smoke density seen by a sensor
can cause a warning or pre alarm condition to be 12 5
triggered by the alarm panel prior to the situation
becoming serious enough to warrant a full alarm.

A typical practical benefit of this technology is the


situation whereby airborne dust particles enter smoke 11 6
detectors and mimic the appearance of smoke, over
time the concentration of dust can increase to a point
where it can cause the detector to falsely trigger an 10 9 8 7
alarm condition. With an intelligent addressable
system, a pre alarm condition will normally be
triggered rather than a full alarm giving the building
operator the opportunity to clean or replace the
sensor rather than suffer the disruption of an
unwanted false alarm. Zone 3 Zone 4

48
Intelligent Addressable Product Range

DF6100 Control Panels

DF6100 control panel, interior DF6100 control panel

Overview Features
The Menvier DF6100 range is available as a high • Large versatile touch screen
specification 1 or 2 loop intelligent addressable display
• Competitive single or two loop
control panel, offering sophisticated functionality
system
with simple end user operation. • Spur tolerant soft addressing
• Large selection of compatible
The simplicity of operation, powerful cause and effect ancillaries
programming capability, and competitive pricing • Full network capability
make the system suitable for a wide range of small to • Integral battery and power
medium sized projects. supply
• 200 address capacity per loop
DF6100 uses soft addressing to minimise installation • Approved to EN54 Pt13
time and remove the potential for error associated and EN54 Pt2 and Pt4
with manual addressing.

These panels can operate as a stand alone panel or Benefits


as part of a network with the Menvier range of
• Simple end user interface
DF6000 panels or other DF6100 panels, (additional
• Range of compatible ancillaries
network card required).
• System protocol allows fast
and accurate configuration
The DF6100 panel has an integral power supply and
is supplied with batteries as standard.

An extensive range of compatible intelligent


addressable system ancillaries are available to work
with the DF6100 all of which incorporate an integral
short circuit isolator to provide maximum protection
against short circuits on the loop.

49
Intelligent Addressable Control Panel - DF6100 and DF61002

Technical Specification
Code DF6100 DF61002
Description 1 loop control panel 2 loop control panel
Standards EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1
EN54 Pt13, EN50130-4 EN54 Pt13, EN50130-4
Specification
Number of Loops 1 2
Addresses per Loop 200 200
Number of Conventional 2 monitored for open and short circuit 2 monitored for open and short circuit
Sounder Circuits (max 1.5A combined) (max 1.5A combined)
Auxiliary Fire Routing
Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max)
Auxiliary Fire Protection
Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max)
Auxiliary Fault Routing
Equipment Output (Monitored) 12V dc 30mA (max) 12V dc 30mA (max)
System Operating Voltage 24V dc (nom) 24V dc (nom)
Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15%
Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts,
can also be instigated via input interface can also be instigated via input interface
Auxiliary Relay 1 set of changeover contacts 1 set of changeover contacts
operate in event of fire condition operate in event of fire condition
Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc
Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration
Battery 2 x 7Ah 2 x 7Ah
Environmental
Operating Temperature -5°C to +40°C -5°C to +40°C
Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH
Physical
Construction Steel back box Steel back box
Dimensions (H x W x D) 375mm x 375mm x 95mm 375mm x 375mm x 95mm
Weight 8kg 8kg
Ingress Protection IP30 IP30
Cable entries Top: cable knockouts (20mm) Back: cable aperture Top: cable knockouts (20mm) Back: cable aperture
System Networking Fully Networkable up to 127 panels Fully Networkable up to 127 panels
(requires additional network card, per panel) (requires additional network card, per panel)

Dimensions
D W H (mm) W (mm) D (mm)
375 375 95

Product Codes
Code Description
DF6100 Intelligent addressable 1 loop control panel
DF61002 Intelligent addressable 2 loop control panel
NC Add to end of product code if network card required
DF61NETKIT Network kit (retro fit)
DF6000PR Passive repeater panel
DTPR6000 Touch screen repeater panel
MFALOG Fire alarm system log book

50
Intelligent Addressable Control Panel - DF6100 and DF61002

Installation User Interface Interface Options


1. Panel is designed for surface or recessed mounting 1. The main element of the user interface with • Day night mode override via
(without the need for an additional bezel). DF6100 is a large (120mm x 90mm visible area) external switched signal.
2. Cable entry is by means of top entry knockouts in touch screen display, which provides (Can be a timer).
the metal back box, along with a substantial rear comprehensive user information and also acts as a • Multiple Programmable remote
entry cutout. multifunctional keypad. With other more basic inputs can be set:
3. Panels are wall mounted via keyhole/slot mounting systems, the user is limited to a small number of • Override of day night mode
holes on back of housing. dedicated pushbuttons and consequently system setting
4. Key operated hinged lockable door provides interaction is restricted and complicated. - Photo-thermal detectors
access to all internal wiring. 2. Comprehensive context sensitive help information go to thermal only.
5. Cable entry can either be top or rear. is provided throughout the menus to assist - Rate of rise detectors go
6. Mains input protection is provided by integral fuse unfamiliar users with system operation. to fixed high temperature
7. All external wiring should be in accordance with 3. The DF6100 touch screen display automatically mode.
relevant section of latest edition of BS5839-Pt1. reconfigures to suit the selected function, for - High temperature heat
8. Comprehensive installation and operation manual example, if the change device text menu option is detectors go to rate of
provided with each system. selected, the touch screen is automatically rise mode.
formatted as a full QWERTY keyboard to enable • T1 and T2 timer.
fast and simple text entry. • HMO facility.
System Functionality 4. As well as a large format LCD display providing full • Comprehensive cause and
1. Panel has 3 modes of operation, normal mode, system status information, the panel incorporates effect programming.
user maintenance mode and engineer mode. 16 traditional zone indication LED's to provide • Test per zone or address.
2. User maintenance and engineer modes can only clear information about the status and spread of a • Alarm verification per zone.
be accessed by entering relevant pass codes fire even to a user who is completely unfamiliar • Coincidence detection.
3. Maintenance mode allows access to system test with the operation of the system. In addition there • Disablement of pre assigned
functions, enable and disable menus, view are a number of system status LED's designed to group of addresses.
analogue level menus and functions such as give clear status information to non technical users • Class change.
evacuate, silence alarms and reset. 5. Audible buzzer with mute facility. • Non latching zone input.
4. Engineer mode allows alteration of system 6. Hinged lockable door provides access to all • Evacuate.
configuration and programming of site specific internal wiring and components. • 2 Conventional sounder
data such as device text and sounder circuits provided.
• Zone monitor units can be
programming. Detection Capacity used to connect zones of
5. Engineer mode also allows adding and removal of
devices and alteration of existing text. 1. Up to 200 addresses per loop which can be a suitable conventional detectors
6. DF6100 is designed to ensure simplicity of future mixture of callpoints, detectors, interfaces or loop or loop powered beam
expansion. If an additional device is added after sounders. detectors.
the system has been programmed, the DF6100 will 2. DF6100 panels can be networked with all Cooper • Sounder circuit controllers can
allocate the next available address, it will not alter intelligent addressable and wireless panels. be used to provide additional
any of the existing address number allocation thus conventional sounder circuits
enabling simple updating of ‘as fitted’ drawings without wiring back to main
etc. Similarly if a device is removed, the relevant Alarm Capacity panel.
address is saved as a spare address for future use, • Mains rated input/output unit
1. Up to 80 loop powered outputs per loop available.
the addresses of the remaining devices are not (60 sounders/beacons and 20 I/O units).
affected. • 3 way 24V rated input/output
2. 3 stages of cause and effect programming per unit available.
7. All devices are soft addressed during output device.
commissioning however once allocated, addresses • Spur isolator available to allow
3. 0.8A of panel connected conventional sounders. spurs of intelligent addressable
are locked until manually altered thus enabling 4. Additional conventional sounders can be
simple system additions and deletions without devices.
connected via loop mounted MPU424 units. • Compact input and output
affecting other addresses.
8. In event of an external short circuit occurring, short modules available
circuit isolators on output of the devices nearest to • Shop unit interface allows the
each side of the short circuit open thus isolating connection of a conventional
the short circuit. The panel then drives detection zone along with a
communication from both ends of the loop thus power supply and 2
maintaining full communication with all devices. conventional sounder circuits,
ideal for linking small self
contained units onto a main
addressable panel.

51
Intelligent Addressable Control Panel - DF6100 and DF61002

System Networking Typical System Architecture


DF6000 and DF6100 systems can both be networked 4 independently controlled
together. Up to 126 DF6000 panels, DF6100 panels conventional sounder circuits
and low cost repeaters can be networked together to
operate as a single networked system.

To achieve this each panel must be fitted with a spur of zone of compatible
analogue devices conventional devices
network card (optional extra). When operating as a
networked system all fire and fault event information
can be displayed at every panel.

Panels can be configured by service engineers to


control whether fire and fault information from each Mains
panel is transmitted around the network or not. Supply

sounder controller unit


Silencing and resetting of alarms can also be carried
out from any panel on a networked system.
loop connected
repeater panel
Networked panels are connected using a loop spur isolator unit zone monitor unit
topology as illustrated.

DF6100

3 independent
volt free output
contacts

3 way input/output unit

3 separate inputs
to accept fire or Mains
shop monitor unit
non fire inputs Supply

mains rated
Mains Supply Mains Supply Mains Supply output relay
contact

input/output unit

DF6000, DF6100 and DTPR6000 fire or non


fire input

zone of compatible 2 circuits of


conventional devices conventional
sounders
control panel

Mains
Supply

Mains Supply Mains Supply Mains Supply

network connected
repeater panel
2 circuits of
conventional
sounders

52
Intelligent Addressable Control Panel - DF6100 and DF61002

Standard Panel Connections

MENVIER CONVENTIONAL SOUNDERS


(IF REQUIRIED)

}
SOUNDER SOUNDER
CIRCUIT 1 CIRCUIT 2
-

6K8 EOL RESISTOR*


+
-

6K8 EOL RESISTOR*


+
NO
RELAY 1
AUX

VOLT FREE CHANGE OVER CONTACT


NO C NC
RELAY 2
AUX

VOLT FREE CHANGE OVER CONTACT


+ C NC
RELAY
FAULT

FAULT RELAY
-
A
B
NETWORK 1
X

NETWORK 1
E
A
B Y
NETWORK 2
X

NETWORK 2
E Y
+ 24V OUT
+

24V dc OUTPUT
-
E

E
LOOP 1
S+

F+

LOOP 1 CONNECTIONS
S-

F-
E

E
LOOP 2

LOOP 2 CONNECTIONS (IF DF61002)


S+

F+
S-

F-
START LOOP TERMINALS

FINISH LOOP TERMINALS

* required to be fitted to terminal if circuits not used

53
Intelligent Addressable Product Range

54
Intelligent Addressable Product Range

DF6000 Range Control Panels

DF6000 control panel with printer DF6000 graphite control panel with protective cover and printer

Overview Features
The Menvier DF6000 is a high specification • 1, 2 and 4 loop versions
intelligent addressable control panel available in • Spur tolerant soft addressing
• Full network capability
various loop configurations. It combines
• Optional integral printer
sophisticated functionality with simple operation • Integral battery and power
and a very aesthetically pleasing design. supply
• 200 addresses per loop
The large capacity, ability to support complex cause • Charger with temperature
and effect programming and wide range of user compensation built in
controllable functions make the system suitable for a • Checks battery capacity
diverse range of projects from sheltered housing to
large office developments and industrial applications.
Benefits
DF6000 uses soft addressing to minimise installation • Simple end user interface
time and remove the potential for error associated • Range of compatible ancillaries
with manual addressing. • Easy to design system
• System Integrity
The DF6000 can operate as a stand alone panel or as • Battery life can be extended
part of a networked system. They have powerful
programming options that allow configurable control
over whether messages from specific panels are
transmitted around the network or remain local.

The DF6000 panel has integral power supply and


batteries the batteries are supplied with the panel as
rack mounted panels standard.

An extensive range of compatible intelligent


addressable systems ancillaries are available to work
with the DF6000 all of which incorporate an integral
short circuit isolator to provide maximum protection
against short circuits on the external loop.

55
Intelligent Addressable Control Panels - DF6000 Range

Technical Specification
Code DF60001 DF60002 DF60004
Description 1 loop control panel 2 loop control panel 4 loop control panel
Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4
Specification
Number of Loops 1 2 4
Addresses per Loop 200 200 200
Number of Conventional
Sounder Circuits 4 monitored for open and short circuit 4 monitored for open and short circuit 4 monitored for open and short circuit
Auxiliary Fire Routing
Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max)
Auxiliary Fire Protection
Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max)
Auxiliary Fault Routing
Equipment Output (Monitored) 12V 30mA (max) 12V 30mA (max) 12V 30mA (max)
System Operating Voltage 24V dc (nom) 24V dc (nom) 24V dc (nom)
Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15% 230V ac +10% / -15%
Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts, Terminals for connection of external contacts,
can also be instigated via input interface can also be instigated via input interface can also be instigated via input interface
Auxiliary Relay 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition
Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc
Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration
Battery 2 x 12Ah (standard versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions)
Environmental
Operating Temperature -5°C to +40°C -5°C to +40°C -5°C to +40°C
Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH
Physical
Construction Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS
Dimensions (H x W x D) Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm
EB versions: 395mm x 495mm x 280mm EB versions: 395mm x 495mm x 280mm
Weight 18kg 18kg 18kg
Ingress Protection IP30 IP30 IP30
Cable entries Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm)
System Networking Fully networkable up to 126 panels Fully networkable up to 126 panels Fully networkable up to 126 panels
(requires additional network card - 1 per panel) (requires additional network card - 1 per panel) (requires additional network card - 1 per panel)

Dimensions Product Codes


D2 Code Description
W
DF60001 1 loop control panel
DF60002 2 loop control panel
DF60004 4 loop control panel
H
DF60001P 1 loop control panel, integral printer
DF60002P 2 loop control panel, integral printer
DF60004P 4 loop control panel, integral printer
DF60001G 1 loop control panel, graphite finish
D1
DF60002G 2 loop control panel, graphite finish
DF60004G 4 loop control panel, graphite finish
Description H (mm) W (mm) D1 (mm) D2 (mm) DF60001PG 1 loop control panel, integral printer, graphite finish
Standard 395 495 55 125 DF60002PG 2 loop control panel, integral printer, graphite finish
EB 395 495 55 225 DF60004PG 4 loop control panel, integral printer, graphite finish
DF60002EB 2 loop control panel, extended battery
Note: If surface mounting add D1 and D2 to obtain DF60004EB 4 loop control panel, extended battery
depth dimension. DF60002PEB 2 loop control panel, integral printer, extended battery
DF60004PEB 4 loop control panel, integral printer, extended battery
DF60002GEB 2 loop control panel, graphite finish, extended battery
DF60004GEB 4 loop control panel, graphite finish, extended battery
DF60002PGEB 2 loop control panel, graphite finish, integral printer, extended battery
DF60004PGEB 4 loop control panel, graphite finish, integral printer, extended battery
NC Add to end of product code if network card required
DF6000NETKIT Network kit (for retor fit)
DF6000COV Hinged protective cover kit
DF6000PR Passive repeater panel
* For further information on the 39UERACK 19" rack DTPR6000 Touch screen repeater panel
and associated panels contact Cooper Fire 39UECRACK 19" rack, 39 units high*
technical support: 01302 303350 MFALOG Fire alarm system log book

56
Intelligent Addressable Control Panels - DF6000 Range

Installation User Interface Interface Options


1. Standard panel is designed for surface or recessed 1. The main element of the user interface with • Monitored output to fire routing
mounting (without the need for an additional bezel). DF6000 is a large (120mm x 90mm visible area) equipment.
2. Cable entry is by means of top entry knockouts in touch screen display, which provides • Monitored output to fire
the metal back box, along with a substantial rear comprehensive user information and also acts as a protection equipment.
entry cutout. multifunctional keypad. With other more basic • Monitored output to fault
3. Panels are wall mounted via keyhole/slot mounting systems, the user is limited to a small number of monitoring equipment.
holes on back of housing. dedicated pushbuttons and consequently system • Multiple Programmable remote
4. Front cover retained by screws, accessed after interaction is restricted and complicated. inputs can be set:
opening the printer bay door. 2. Comprehensive context sensitive help information • Override of day night mode
5. Flush mounting requires suitable aperture and is provided throughout the menus to assist setting
fixings. unfamiliar users with system operation. - Photo-thermal detectors
6. Mains input protection is provided by a polyswitch. 3. The DF6000 touch screen display automatically go to thermal only.
7. All external wiring should be in accordance with reconfigures to suit the selected function, for - Rate of rise detectors go
relevant section of latest edition of BS5839-Pt1. example, if the change device text menu option is to fixed high temperature
8. Comprehensive installation and operation manual selected, the touch screen is automatically mode.
provided with each system. formatted as a full QWERTY keyboard to enable - High temperature heat
9. Maximum length of network cable loop is 1500 fast and simple text entry. detectors go to rate of
metres, beyond this distance or where cables pass 4. As well as a large format LCD display providing full rise mode.
between buildings, boosters will be required. system status information, the panel incorporates • Disablement of pre assigned
96 traditional zone indication LED's to provide group of addresses.
clear information about the status and spread of a • Class change.
System Functionality fire even to a user who is completely unfamiliar • Non latching zone input.
1. Panel has 3 modes of operation, normal mode, with the operation of the system. In addition there • Evacuate.
user maintenance mode and engineer mode. are a number of system status LED's designed to • 4 Conventional sounder
2. User maintenance and engineer modes can only give clear status information to non technical users circuits provided.
be accessed by entering relevant pass codes 5. Access to printer (when fitted) is via separate • Zone monitor units can be
3. Maintenance mode allows access to system test locked access door. Paper can be changed by non used to connect zones
functions, enable and disable menus, view skilled personnel without exposure to any live of suitable conventional
analogue level menus and functions such as components. detectors and callpoints.
evacuate, silence alarms and reset. 6. The printer can either be set to print on demand or • Sounder circuit controllers can
4. Engineer mode allows alteration of system to automatically print all system events as they be used to provide additional
configuration and programming of site specific occur. conventional sounder circuits
data such as device text and sounder 7. The hinged front door provides simple access to all without wiring back to main
programming. internal components and wiring. panel.
5. Engineer mode also allows adding and removal of 8. The panel door cannot be opened without the use • Mains rated input/output unit
devices and alteration of existing text. of a special key (supplied with panel). available.
6. DF6000 is designed to ensure simplicity of future 9. For applications requiring a high level of resilience, • 3 way 24V rated input/output
expansion. If an additional device is added after a clear hinged lockable front cover is available that unit available.
the system has been programmed, the DF6000 will still allows full system visibility but prevents • Spur isolator available to allow
allocate the next available address, it will not alter unauthorized access to the touch screen. spurs of intelligent addressable
any of the existing address number allocation thus devices.
• Compact input and output
enabling simple updating of ‘as fitted’ drawings Detection Capacity modules available
etc. Similarly if a device is removed, the relevant
address is saved as a spare address for future use, 1. Up to 200 addresses per loop which can be a • Shop unit interface allows the
the addresses of the remaining devices are not mixture of callpoints, detectors, interfaces loop connection of a conventional
affected. sounders or repeaters. detection zone along with a
7. All devices are soft addressed during 2. To comply with EN54 requirements no more than power supply and 2
commissioning however once allocated, addresses 512 addresses should be connected to a single conventional sounder circuits,
are locked until manually altered thus enabling panel. ideal for linking small self
simple system additions and deletions without 3. Panels are available with up to 4 detection loops, contained units onto a main
affecting other addresses. up to 126 panels can be networked together giving addressable panel.
8. In event of an external short circuit occurring, short a total system capacity of over 32,000 devices.
circuit isolators on output of devices nearest to
each side of the short circuit open thus isolating
the short circuit. The panel then drives
Alarm Capacity
communication from both ends of the loop thus 1. Up to 80 loop powered outputs per loop
maintaining full communication with all devices. (60 sounders/beacons and 20 I/O units).
2. 3 stages of cause and effect programming per
output device.
3. Depending on loop load up to 3A of panel
connected conventional sounders.
4. Additional conventional sounders can be
connected via loop connected MPU424 units.

57
Intelligent Addressable Control Panels - DF6000 Range

System Networking Typical System Architecture


DF6000 and DF6100 systems can both be networked 4 independently controlled
together. Up to 126 DF6000 panels, DF6100 panels conventional sounder circuits
and low cost repeaters can be networked together to
operate as a single networked system.

To achieve this each panel must be fitted with a spur of zone of compatible
analogue devices conventional devices
network card (optional extra). When operating as a
networked system all fire and fault event information loops 2-4
can be displayed at every panel. if fitted

Panels can be configured by service engineers to


control whether fire and fault information from each Mains
panel is transmitted around the network or not. Supply

sounder controller unit


Silencing and resetting of alarms can also be carried
out from any panel on a networked system. loop connected
repeater panel
Networked panels are connected using a loop spur isolator unit zone monitor unit
topology as illustrated.

Networking DF6000

3 independent
volt free output
contacts

3 way input/output unit

3 separate inputs
to accept fire or Mains
shop monitor unit
non fire inputs Supply

mains rated
Mains Supply Mains Supply Mains Supply
output relay
contact

input/output unit

DF6000, DF6100 and DTPR6000 fire or non


fire input

zone of compatible 2 circuits of


conventional devices conventional
sounders
control panel

Mains
Supply

Mains Supply Mains Supply Mains Supply

network connected
2 circuits of repeater panel
conventional
sounders

58
Intelligent Addressable Control Panels - DF6000 Range

Standard Panel Connections

+5.5V SUPPLY FOR PRINTER (IF FITTED)

}
NO
RELAY
AUX

VOLT FREE CHANGE OVER CONTACT


NC
- +
RELAY
FAULT

6K8 EOL RESISTOR*


+24V

- +
O/P

-
FIRE
R/E

6K8 EOL RESISTOR*


+
FIRE

- +
P/E

6K8 EOL RESISTOR*


S+

START LOOP 1
LOOP 1

S-
F-

FINISH LOOP 1
F+
S+

START LOOP 2
LOOP 2

S-
F-
LOOP CIRCUITS

FINISH LOOP 2
F+
S+

START LOOP 3
LOOP 3

S-
F-

FINISH LOOP 3
F+
S+

START LOOP 4
S-
LOOP 4

F-

FINISH LOOP 4
F+
CHANGE

- +
CLASS

CLASS CHANGE INPUT IF REQUIRED


+
SOUNDER
CIRCUIT 1

1-
+
2-
+
SOUNDER
CIRCUIT 2

1-
+

6K8 EOL RESISTOR*


2-

}
Tx
MODEM/PC

Rx

MENVIER CONVENTIONAL SOUNDERS


Rs232

(IF REQUIRED)
CTS RTS 0V
REPEATER

Tx+ Tx-
MIMC

* required to be fitted to terminal if circuits not used

59
Intelligent Addressable Product Range

60
Intelligent Addressable Product Range

Passive Repeater Panel DF6000PR

simple user interface DF6000PR passive repeater panel

Overview Features
The DF6000PR is a cost effective passive repeater • Up to 20 repeaters can be
panel which can be programmed via its informative connected to the loop
• 2 x 40 backlit LCD display and
display to be either fully passive (display only) or
6 supervisory LED’s
semi passive (restricted system control). • Compact size
• Can be surface or semi-
When loop connected the repeater panel will display recessed mounted
the system information text of the connected control
panel and will provide a fire indication, with panel
number, of any connected network control panel that Benefits
2 x 40 backlit LCD display and 6 supervisory LED’s has fire activation.
• Menu driven easy to operate
The DF6000PR repeater panel only requires • Simple connection to panel
programming with local text information. loop circuit reduces wiring and
installation time
In addition to the repeater panels main menu driven • Distance run up to 2km from
2 x 40 backlit LCD display, which provides system main panel without additional
status information, it also has 6 supervisory LED’s cable and equipment, saving
(Power On, Alarm, Trouble, Supervisory, Test In cost
Progress, and Scroll).

61
Intelligent Addressable Passive Repeater Panel - DF6000PR

Dimensions Technical Specification


D1
W Code CF30000PR
Description Passive repeater panel
Standards EN54 Pt4
Specification

MUTE SCROLL
Mains Input Voltage 230V ac +10% / -15%
BUZZER

H
1 2 3 4 5
Operating Voltage 24V dc
System Indicators Power on, fire, fault, test, disable and scroll
System Controls Silence alarms, evacuate and reset
Input Ports RS232 (for connection of programmer)
D2 Battery 1 x 12V 3.2Ah
Standby Duration 24 hours
Environmental
H (mm) W (mm) D1 (mm) D2 (mm) Operating Temperature 0°C to +25°C
270 332 45 47 Humidity (Non Condensing) 0 to 75% RH
Physical
Construction PC/ABS
Colour Light Grey
Dimensions (H x W x D) 332mm x 270mm x 92mm
Weight 3.6kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

6. When connected to a detector


Loop Connected Installation loop, text for host is
1. Wall mounted by means of 4 fixing screws. downloaded to repeater and
2. Cable entry at top or back. updated manually as required.
3. 12 top entry gland holes with push out blanking 7. Zonal fire and fault indication is
plugs. by means of 2 x 40 character
4. 4 separate rear access cable entry facilities. LCD display.
5. Local mains supply required.

Mains Supply
Device Overview
System Functionality 1. Panel can be connected to
1. Panel operates in either normal, supervisor or either the detection loop of a
Mains Supply
engineer mode. single panel or to a network as
2. Supervisor and engineer modes are accessed via part of a networked system.
Network Link
4 digit pass codes. 2. Supplied with integral power
3. Supervisor mode allows silence, evacuate and supply and standby battery.
Note: In this configuration the repeater would give
‘text’ information for the panel that is on the reset commands to be sent to host panel (loop
loop, but only address number for the other connected) or to network (network connected).
panel on the network. 4. Engineer mode enables password to be changed if
required and allows access to text download menu
5. When connected to network, all text is transmitted
Network Connected via network, changes to other network panels
update automatically.

Standard Connection
SCREEN
SCREEN

SCREEN

Rs485 LOOP LOOP


MIMIC OUT IN
Tx +
Tx -

TEXT DOWNLOAD - + - +

Mains Supply

Network Link

Product Codes
Code Description
DF6000PR Intelligent addressable passive repeater panel, loop connected
DF6000PRNC Intelligent addressable passive repeater panel, network connected

62
Intelligent Addressable Product Range

Touch Screen Repeater Panel DTPR6000

DTPR6000 touch screen repeater panel

Overview Features
The DTPR6000 touch screen repeater panel • Plug and play. All information is
provides sophisticated ‘touch screen’ functionality downloaded through the
network
yet achieves a simple end-user interface operation
• Touch-screen display
within a compact panel design. • Integrated network capability
allows networking with the
The DTPR6000 is designed to work with all Menvier latest Menvier range of
intelligent addressable fire alarm control panels as intelligent addressable fire
well as other network repeaters. alarm control panels
• Multi language capability
The Menvier touch-screen repeater panel is easy to • Up to 126 repeaters can be
install and commission. All text is transmitted via the connected to the network
network and is automatically updated. • Programmable as an active or
passive repeater

Benefits
• Plug and play requires no
programming
• User friendly touch screen
display
• System integrity, fire alarm
system continues to operate
even if there is a short circuit or
open joint on cable
• Multi language capability

63
Touch Screen Repeater Panel - DTPR6000

Dimensions Technical Specification


D W
Code DTPR6000
Description Touch screen repeater panel
Standards EN54 Pt4
Specification
Mains Input Voltage 230V ac +10% / -15%
H Operating Voltage 24V dc

System Indicators Power on, fire, fault, test, disable and scroll
System Controls Silence alarms, evacuate and reset
Input Ports RS232 (for connection of programmer)
Battery 2 x 12V 3.2Ah
Standby Duration 24 hours
H (mm) W (mm) D1 (mm) Environmental
375 537 50 Operating Temperature -5°C to +40°C
Humidity (Non Condensing) 0 to 75% RH
Physical
Construction PC/ABS
Colour Graphite
Dimensions (H x W x D) 375mm x 357mm x 50mm
Weight 8kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Network Connected Installation Device Overview


• Wall mounted by means of 4 fixing screws. • Panel is connected to the
• Cable entry at top or back. network as part of a networked
• 11 top entry gland holes. system.
• Separate rear access cable entry facility. • Supplied with integral power
• Local mains supply required. supply and standby battery.
• Must be network connected. • Touch screen user interface.

System Functionality
• Panel operates in either normal, supervisor or
Mains Supply engineer mode.
• Supervisor and engineer modes are accessed via
Network Link 4 digit pass codes.
• Supervisor mode allows full system operation.
• Engineer mode enables password to be changed if
required and allows access to text download menu
• When connected to network, all text is transmitted
via network, changes to other network panels
update automatically.

Standard Connection
+24V dc +24V dc FAULT AUX PROGRAMMABLE
NETWORK 1 NETWORK 2
IN OUT RELAY RELAY INPUT

+ - + - A B X Y E A B X Y E NO C NC NO C NC E

TO PANEL EARTH

Product Codes
Code Description
DTPR6000 Intelligent addressable touch screen repeater panel

64
Intelligent Addressable Product Range

Sensors MAP820, MAOH850 and MAH830

MAP820 optical sensor

MAOH850 photo-thermal sensor optical / photo-thermal / heat detectors

Overview Features
The Menvier range of intelligent addressable • Soft addressed
sensors have been specifically designed to operate • Integral short circuit isolator
• Wide range of sensor types
with Menvier intelligent addressable control panels.
• 360° visibility LED

All sensors are third party approved to the relevant


section of EN54 (part 7 for smoke detectors & part 5 Benefits
for heat detectors).
• Single ‘multi-mode’ heat
sensor
MAH830 heat sensor

65
Intelligent Addressable Sensors - MAP820, MAOH850 and MAH830

Technical Specification
Code MAP820 MAOH850 MAH830
Description Optical smoke sensor Photo-thermal sensor Multi-mode heat sensor
Standards EN54 Pt7 2000 + A1:2002 EN54 P5 & P7 2000 + A1:2002 EN54 Pt5 2000 + A1:2002
Operating voltage 18V dc to 30V dc 18V dc to 30V dc 18V dc to 30V dc
Standby Current 220µA (max) 220µA (max) 220µA (max)
Alarm Current 5mA (max) 5mA (max) 5mA (max)
Addressing Mode Auto address Auto address Auto address
Specification
Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas
Mounting Options Surface mount with MAB800 base Surface mount with MAB800 base Surface mount with MAB800 base
Area Coverage 100m² (subject to local standard) 100m² (subject to local standard) 50m² (subject to local standard)
System Wiring Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur
Heat Class
Rate of Rise N/A A1S A1R
Fixed Heat 77ºC N/A N/A BS
Fixed Heat 90ºC N/A N/A CS
Alarm Temperature (static)
AIR N/A 60ºC 60ºC
BS N/A N/A 77ºC
CS N/A N/A 90ºC
Indication 360° visibility light pipe 360° visibility light pipe 360° visibility light pipe
Environmental
Operating Temperature -20°C to +60°C -20°C to +50°C -20°C to +60°C
Humidity (non condensing) 0 to 95% RH 0 to 95% RH 0 to 95% RH
Physical
Construction PC/ABS PC/ABS PC/ABS
Colour White White White
Dimensions Excl Base (Dia x D) 101mm x 33mm 101mm x 43mm 101mm x 43mm
Dimensions Incl Base (Dia x D) 104mm x 45mm 104mm x 55mm 104mm x 55mm
Weight (without base) 76g 76g 76g
Compatibility
Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Dimensions Installation User Interface


1. Sensors are fixed and wired via common 1. LED indicates detector status,
Dia mounting base. can be set to flash to confirm
2. Cable entry into base can be rear or side. communication with control
3. A locking facility is provided which can be panel, illuminates continuously
activated if required to prevent unauthorised under fire conditions.
sensor removal without the use of a special tool. 2. All wiring connections are via a
D
common mounting base
Note: For wiring information please see (ordered separately).
MAB800 base

Description Dia (mm) D (mm) D (mm)


(excl base) (incl base)
Optical 101 33 45
Photo-thermal 101 43 55
Multi-mode heat 101 43 55

Product Codes
Code Description
MAP820 Intelligent addressable optical smoke sensor
MAOH850 Intelligent addressable photo/thermal sensor
MAH830 Intelligent addressable multi-mode heat sensor
MAB800 Intelligent addressable common base
MAB800*10 Intelligent addressable common base (pack of 10)
MDP201 Duct Probe

66
Intelligent Addressable Product Range

Standard Base MAB800


Suitable sensors for use with the
MAB800 standard base

MAP820 optical sensor

MAB800 standard base

Overview Features
MAOH850 photo-thermal sensor • Sensor shorting link
The MAB800 Menvier intelligent addressable
standard base has been specifically designed to be • Separate loop in and loop out
terminals
compatible with Menvier intelligent addressable
• Stand off fixing feature
sensors. • Accepts side entry cables
• Selectable sensor locking
This standard base has been designed for flexibility, feature
simplicity and speed of installation. It incorporates a
purpose designed shorting link to ensure wiring
continuity if a sensor is removed. Benefits
The standard base incorporates a retaining clip to • Quick and simple to install
provide positive feedback when sensor is correctly • Accepts side entry surface
fitted and a retaining clip that can be replaced with cables
locking device (supplied with base) to prevent • Common base for Menvier
MAH830 multi-mode heat sensor unauthorised sensor removal. intelligent addressable sensors

67
Intelligent Addressable Standard Base - MAB800

Dimensions Technical Specification


Dia (mm) D (mm) Code MAB800

104 22 Description Standard base


Physical
D Construction PC/ABS
Colour White
Dimensions (Dia x D) 104mm x 22mm
Compatibility
Suitable for use with Menvier intelligent addressable sensors

Dia

Installation User Interface


1. Separate terminals are provided for loop in and 1. Heavy duty terminals are
loop out connections. provided for each connection,
2. Each terminal can accept up to 2 x 2.5mm cables. each terminal can accept
3. Base incorporates a substantial cable entry 2 x 2.5mm cables.
aperture in the rear of the base. 2. Separate loop in and loop out
4. Breakouts are provided to enable the sensor terminals are provided for each
base to sit neatly over surface cables and then connection.
enter via the rear entry aperture.
5. Base mounting incorporates a stand off feature to
help prevent distortion when mounted on an
uneven surface.
6. Fixings are suitable for standard BESA box or
direct fixing to suitable surface.

Standard Connection

+
remote indicator (optional)
+V
S+ 4 4
Intelligent Addressable

E E
Loop start
Compatible Menvier

S-
Control Panel

3 3
LED

LED

F-
Loop finish

1 1
F+
2 2

- VE OUT

- VE IN

earth screen of cable must be continuous

WARNING:
If using the outer connection on terminal 2, ensure the operation of the switch is not impeded
and that there are no shorts between terminal 2 and the switch contact

Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code Description
MAB800 Intelligent addressable standard base

68
Intelligent Addressable Product Range

Sounder Base MAS850

MAS850 with cover fitted

MAS850 sounder base

Overview Features
The intelligent addressable Menvier sounder base • Integral sensor mounting base
has been developed specifically to operate with the • Can be used with a sensor as
a sounder base or stand alone
latest generation of Menvier intelligent addressable
sounder
panels and to complement the latest generation of • Optional cover plate available
Menvier intelligent addressable sensors.
MAS850 incorporates standard detector base
The MAS850 sounder base incorporates a sensor Benefits
mounting base, a sensor can be fitted to the sounder
• First fix base
base or alternatively an optional cover plate can be
• Selectable tones controlled by
used to enable the sounder to operate as a dedicated
the panel
discreet stand alone sounder.
• Adjustable volume controlled
by the panel

69
Intelligent Addressable Sounder Base - MAS850

Dimensions Technical Specification


Code MAS850
Dia (mm) D (mm) Description Sounder base
102 40 Standards EN54 Pt3
Specification
D
Operating Voltage 17V dc to 32V dc
Standby Current < 320μA
Tones (set by panel) Continuous: 910Hz
Pulsed: 910Hz / 0Hz pulse 1Hz
Two tone: 610 / 910Hz @ 1Hz cycle
Dia
Slow whoop
Sound Output @ +/-3dB Low volume : 84dB at <4mA
(set by panel) Medium volume : 92dB at <8mA
High volume : 95dB @ <12mA
Environmental
Operating Temperature -10 to +55°C
Humidity (Non Condensing) 0 to 95% RH
Physical
Construction PC/ABS
Colour White
Dimensions (Dia x D) 120mm x 40mm
Weight 0.2kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

7. Sensor or cover plate is then


Installation fixed to sounder.
1. Installation is simple using first fix base. 8. Sensor or cover plate can be
2. First fix base is fixed to mounting surface via locked in place if required.
2 fixings holes.
3. Cables enter through aperture in base (rear entry System Functionality
only)
4. Main body is then clipped into place on base, main 1. Volume and tone are set by
body locks into place when pressed into position. control panel, no need to
5. Cables pass through aperture in sounder body and access sounder to alter
terminate at the front. setting.
6. Connections are to connector block on front of 2. Soft addressed.
main sounder body.

Standard Connection

3 3
Intelligent Addressable

Loop start

- -
Compatible Menvier

+ - + + - +
S+ 2 E 2
Control Panel

E
S-
4 4
Loop finish

F-
LED 1 LED 1

F+

WARNING:
Do NOT use high voltage testers if ANY equipment is connected to the system.
Earth screen must be continuous along entire length of loop.

NOTE:
Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Product Codes
Code Description
MAS850 Intelligent addressable sounder base
MASC Sounder cover plates (pack of 5)

70
Intelligent Addressable Product Range

Sounder Beacon Base MASB870

MASB870 sounder beacon base

MASB870 with sensor fitted

Overview Features
The intelligent addressable Menvier sounder • Integral sounder base
beacon base has been developed specifically to • Integral high output LED
beacon
operate with the latest generation of Menvier
• Integral sensor mounting base
intelligent addressable panels and Menvier sensors. • Can be used with a sensor or
stand alone
The MASB870 sounder beacon base includes all the • Selectable tones controlled by
features of the intelligent addressable sounder base the panel
as well as a powerful LED beacon. • Adjustable volume controlled
by the panel
The intelligent addressable beacon base incorporates • Optional cover plate available
a detector mounting base, a sensor can be fitted
directly to the base, or alternatively an optional cover
plate can be used to provide a dedicated discreet Benefits
stand alone device.
• Saves time and installation
costs
• Single point connection for
sensor, sounder and LED
strobe

71
Intelligent Addressable Sounder Beacon Base - MASB870

Dimensions Technical Specification


Code MASB870
Dia (mm) D (mm) Description Sounder beacon base
Dia
115 44 Standards EN54 Pt3
Specification
Operating Voltage 17V dc to 32V dc
D
Standby Current < 320μA
Tones (set by panel) Continuous: 910Hz
Pulsed: 910Hz / 0Hz pulse 1Hz
Two tone: 610 / 910Hz @ 1Hz cycle
Slow whoop: 500 – 1200Hz in 3.5 Seconds
Sound Output at +/-3dB Low volume : 77dB at <6.6mA
(set by panel) Medium volume : 89dB at <8mA
High volume : 90dB @ <9mA
Environmental
Operating Temperature -10 to +55°C
Humidity (Non Condensing) 0 to 95% RH
Physical
Construction PC/ABS
Colour White
Dimensions (Dia x D) 115mm x 44mm
Weight 0.2kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation System Functionality


1. Installation is simple using first fix base. 1. Volume and tone are set by
2. First fix base is fixed to mounting surface via control panel, no need to
2 fixings holes. access sounder to alter setting.
3. Cables enter through aperture in base (rear entry 2. Soft addressed.
only)
4. Main body is then clipped into place on base, main
body locks into place when pressed into position.
5. Connections are to connector block on front of
main sounder body.
6. Sensor or cover plate is then fixed to sounder, (can
be locked in place if required).

Standard Connection

3 3
Intelligent Addressable

Loop start

- -
Compatible Menvier

+ - + + - +
S+ 2 E 2
Control Panel

E
S-
4 4
Loop finish

F-
LED 1 LED 1

F+

WARNING:
Do NOT use high voltage testers if ANY equipment is connected to the system.
Earth screen must be continuous along entire length of loop.

NOTE:
Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Product Codes
Code Description
MASB870 Intelligent addressable sounder beacon base
MASC Sounder beacon cover plates (pack of 5)

72
Intelligent Addressable Product Range

Loop Connected Remote Indicator MRIAD

MRIAD loop connected remote indicator

Overview Features
• Simple to install
The MRIAD intelligent addressable loop connected • Fits onto standard single gang
remote indicator is designed to provide discreet back box
remote indication, which is controlled by the • Wide viewing angle high
intelligent addressable fire panel, whilst providing brightness LED
• Attractive styling
the ability to monitor multiple detectors within an
area thereby minimising wiring requirements.
Benefits
The unit is connected directly on the loop, is ‘soft
• Can be remote mounted
addressed’ by the panel on system start up and is
• Controlled by the panel
fitted with integral short circuit isolators.
• Can be activated by cause and
effect
When using “Site installer” the MRIAD should be
• Reduced cost
programmed as an address output (sounder) and
• Minimises cabling
can be programmed using the comprehensive cause
and effect tables to operate continuous, pulsing, by
global, panel, zone, address or on double knock input
etc.

The unit is supplied complete with back box and is


surface mounted.

73
Intelligent Addressable Remote Indicator - MRIAD

Dimensions Technical Specification


D
H (mm) W (mm) D (mm) Code MRIAD

87 87 49 Description Loop connected remote indicator


Specification
Operating Voltage 24V dc
H Quiescent Current 220μA
Alarm Current 6mA
Cable Size 0.5 mm² to 2.5 mm²
Environmental
W Operating Temperature -10°C to +55°C
Humidity (Non Condensing) 0 to 95% RH
Physical
Construction ABS
Colour White
Lens Colour Red
Dimensions (H x W x D) 87mm x 87mm x 49mm
Weight 0.28kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Standard Connection Installation System Functionality


MRIAD 1. Mounting plate fixes to single gang back box or 1. MRIAD is addressable and is
can be direct fixed to wall or ceiling. programmed to activate when
screen connected using suitable terminal in backbox
2. Cable entry is normally from rear but breakouts are selected detectors are
provided in side of base plate triggered.
3. Cables connect to terminals on PCB within base 2. LED cancels when detector is
OUT
IN

plate. reset.
- + - + 4. Front cover is pushed onto base plate and locks in 3. Low current consumption.
place.
LOOP

LOOP

Compatible Menvier
OUT
IN

Intelligent Addressable
Control Panel

Terminal block unplugs


for ease of connection

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Screen (Earth) must be continuous along entire length of loop.

Product Codes
Code Description
MRIAD Intelligent addressable loop connected remote indicator

74
Intelligent Addressable Product Range

Reflective Beam Detectors MAB50R and MAB100R

optional mounting bracket with cable clamp facilities

MAB50R and MAB100R reflective beam detectors

Overview Features
The Menvier loop powered reflective beam • Quick and simple to install
detectors are specifically designed to function with • IP40 protection
• Simple loop connection
the latest intelligent addressable Menvier control
• No power supply required
panels.
combined transmitter and receiver for ease of
installation Two versions are available, the MAB50R with a range Benefits
of up to 50 metres, and the MAB100R with a range of
50 - 100 metres. • Saves time and installation
costs
Both of these units are extremely simple to install, • Single device to install instead
they require no separate power supply, operate on a of numerous point detectors
reflective principle and have a simple set up mode to • Single point of maintenance
enable easy and quick alignment during installation. • Wall mounted for ease of
maintenance, especially in
Beam detectors are designed to replace individual warehouses with racking
point detectors in large open areas such as
warehouses.

Fire and fault conditions are signalled to panel using


standard loop wiring so no additional interconnection
required.

75
Intelligent Addressable Reflective Beam Detectors - MAB50R and MAB100R

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MAB50R MAB100R

210 130 120 Description Reflective beam detector Reflective beam detector
Standards EN54 Pt 12 & 17 2002 EN54 Pt 12 & 17 2002
Specification
H D
Operating Voltage 18V dc to 30V dc 18V dc to 30V dc
Quiescent Current <5mA (no LED’s illuminated) <5mA (no LED’s illuminated)
Alarm Current <9mA <9mA
Alignment Current <18mA <18mA

W Power up Time 10 seconds (approx) 10 seconds (approx)


Operating Range 5 to 50 metres 50 to 100 metres
Tolerance to Beam
Misalignment at 35% Detector ± 0.8°, Prism ± 5.0° Detector ± 0.8°, Prism ± 5.0°
Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%)
Optical Wavelength 880nm 880nm
Environmental
Operating Temperature -10°C to +55°C -10°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
Physical
Construction PC/ABS PC/ABS
Colour White White
Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm
Weight 0.8kg 0.8kg
Ingress Protection IP40 IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Standard Connection Installation System Functionality


MAB50R / MAB100R 1. Must be fixed to solid structure. 1. Beam detectors have 3 modes
2. Recommended mounting height is 0.3 to 0.6 • Prism targeting mode
to beam detector socket metres below the ceiling. designed to provide simple
3. Cables can be terminated into separate termination initial alignment of beam and
box (not supplied) or use purpose designed reflector assembly.
OUT

mounting bracket (MRBFP) ordered separately.


IN

• Alignment mode
4. Mounting bracket has facilities for glanding of Enables accurate fine tuning
+ - + -
incoming cables plus simple fixing of beam of beam alignment without
LOOP

LOOP

Compatible Menvier
OUT

detector.
IN

Intelligent Addressable the need for additional


Control Panel 5. Test filter is supplied with detector to simulate calibration equipment or a
required smoke obscuration level and confirm second operator.
correct operation.
• Normal running mode
screen connected using suitable terminal in backbox

WARNING: User Interface


Do NOT use high voltage testers if ANY equipment is
connected to the system. 1. Beam detectors status LEDs
• Red LED constantly
Screen (Earth) must be continuous along entire length of loop.
illuminated indicates fire
condition
• Flashing amber LED
indicates fault condition

Product Codes
Code Description
MAB50R Intelligent addressable reflective beam detector 50m range
MAB100R Intelligent addressable reflective beam detector 100m range
MRBFP Mounting bracket

76
Intelligent Addressable Product Range

Callpoints MBG813 and MBG817

MBG817 weatherproof callpoint

MBG813 callpoint

Overview Features
This attractively designed simple to install range of • Fast fit clip on front cover
callpoints have been specifically developed to be • High visibility status LED
• Standard and weatherproof
compatible with Menvier intelligent addressable fire
versions available
systems. • Wide range of available
accessories
There are two versions of callpoint in this range. The • Heavy duty terminals
MBGHCC protective hinged cover MBG813 which can be either surface or flush
mounted and the MBG817 weatherproof version.
Benefits
All callpoints are supplied as standard with a
frangible glass element and a test key for ease of • Quick and simple to install
maintenance. • Fast fit clip on front cover
• Single tool for test and access
A comprehensive range of accessories are available
to maximise the functionality of the callpoint for
particular applications.

MBGBEZ recessing bezel

77
Intelligent Addressable Callpoints - MBG813 and MBG817

Dimensions Technical Specification


W Code MBG813 MBG817
Description Surface / flush mounting callpoint Weatherproof callpoint
Standards EN54 Pt11 EN54 Pt11
Specification
Operating Voltage 17V dc to 32V dc 17V dc to 32V dc
H
Quiescent Current < 250μA < 250μA
Environmental
Operating Temperature -10°C to +55°C -10°C to +55°C
Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH
D
Physical
Construction PC/ABS PC/ABS

Description H (mm) W (mm) D (mm) Colour Red Red


Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm
Flush mounted 87 87 36
Weight 0.2kg 0.2kg
Surface mounted 87 87 57
Ingress Protection IP42 IP65
Weatherproof 87 87 59
Compatibility
Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Standard Connection Installation Accessories


MBG813 / MBG817 1. Surface callpoint has standard rear BESA fixing • Semi recess bezel
facilities. In addition, back box can accept top or • Spacer plates
bottom surface entry cables. Surface callpoint can • Hinged clear cover
Screen

Screen

OUT

also be flush mounted. • Resettable plastic element


IN

2. Callpoint has test facility via special test key to • Replacement test key
E - + E - + prevent unauthorised operation. • Replacement glass elements
LOOP

LOOP

Compatible Menvier 3. Insertion of test key for test purposes and for cover • Earth continuity links
OUT
IN

Intelligent Addressable
Control Panel removal is at bottom of callpoint to facilitate ease
of access when mounted next to door architrave.
WARNING:
4. Test key is dual function, used to test callpoint
Do NOT use high voltage testers if ANY equipment is operation by simulating activation and also to allow
connected to the system. removal of clip on cover to gain access to element.
5. Element is held in place by clip on self locking
Screen (Earth) must be continuous along entire length of loop. cover which can only be removed by use of a
special tool (callpoint test key).
6. Separate loop in and loop out terminals are
provided for all connections including screen
continuity on intelligent addressable callpoints.
7. Surface/flush callpoints are IP42, weatherproof is
IP65.

User Interface
1. To enable quick and simple installation, callpoints
use a fast fit self locking clip on front cover which
is very simple to fit, but once in place, can only
be removed by use of a special key (supplied).
2. Callpoint is triggered by pressing against the
element.

Product Codes
Code Description
MBG813 Intelligent addressable surface/flush callpoint
MBG817 Intelligent addressable weatherproof callpoint
MBGHCC Protective hinged cover
MBGSP Spacer plates (pack of 10)
MBGBEZ Recessing bezels (pack of 10)
MBGREKIT Resettable element kit (pack of 10)
MBG118 Spare break glasses (pack of 5)
MBG119 Earth continuity links (pack of 5)
MFBGKEY3 Callpoint keys (pack of 10)

78
Intelligent Addressable Product Range

Wall Sounders MAS850LPS and MAS850LPSWP

MAS850LPSWP weatherproof wall sounder MAS850LPS internal wall sounder

Overview Features
The Menvier intelligent addressable wall sounder MAS850LPS
has been developed specifically to operate with • Loop powered
Menvier intelligent addressable control panels. • High efficiency design
• Selectable tones controlled by
the panel
The high efficiency design of these wall sounders
• Adjustable volume controlled
offer excellent sound output levels despite the low
by the panel
current consumption.
• Simple clip fixing assembly

MAS850LPS
MAS850LPSWP
internal base The Menvier MAS850LPS is designed for wall
• Weatherproof version (IP66)
mounting, has a choice of different tones and volume
• Loop powered
levels, a built in short circuit isolator and is soft
• High efficiency design
addressed for ease of installation.
• Selectable tones controlled by
the panel
MAS850LPSWP • Adjustable volume controlled
The Menvier MAS850LPSWP is IP66 rated so by the panel
suitable for external and wash down areas, it is • Simple clip fixing assembly
designed for wall mounting, has a choice of different
tones and volume levels, a built in short circuit
isolator and is soft addressed for ease of installation. Benefits
• Low current consumption
• First fix back box
• Built in short circuit isolators

weatherproof base

79
Intelligent Addressable Wall Sounders - MAS850LPS and MAS850LPSWP

Dimensions Technical Specification


Code MAS850LPS MAS850LPSWP
w
D
Description Internal wall sounder Weatherproof wall sounder
D Standards EN54 Pt3 EN54 Pt3
Specification

H
Operating Voltage 17V dc to 32V dc 17V dc to 32V dc
H
Standby Current < 320μA < 320μA
Tones (set by panel) Continuous: 984Hz Continuous: 984Hz
Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz
W Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle
Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap
Internal Weatherproof Sound Output @ +/-3dB Low volume : 87dB at <2mA Low volume : 87dB at <2mA
wall sounder wall sounder (set by panel) Medium volume : 93dB at <3mA Medium volume : 93dB at <3mA
High volume: 100dB @ <6mA High volume: 100dB @ <6mA
Environmental
Description H (mm) W (mm) D (mm) Operating Temperature -10°C to +55°C -10°C to +55°C
Internal 105 105 95 Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH
Weatherproof 108 108 103 Physical
Construction PC/ABS PC/ABS
Colour Red Red
Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm
Weight 0.25kg 0.57kg
Ingress Protection IP42 IP66
Cable Entry Rear/side Rear/side
Compatibility
Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Standard Connection Installation System Functionality


MAS850LPS / MAS850LPSWP MAS850LPS MAS850LPS / MAS850LPSWP
1. Installation is simple using first fix base. 1. Volume is set by fire control
Screen

Screen

2. First fix base is fixed to mounting surface using panel, no need to access
OUT

2 fixing holes. sounder to alter setting.


IN

3. Cable entry can be rear or side. 2. Tone is set by fire control


E - + E - + 4. Connections are to connector block on main panel, no need to access
LOOP

LOOP

Compatible Menvier
OUT

sounder body. sounder to alter setting.


IN

Intelligent Addressable
Control Panel 5. Main body is then clipped into position on
mounting base, body locks into position when
WARNING: pressed home.
Do NOT use high voltage testers if ANY equipment is
connected to the system. MAS850LPSWP
1. Installation is simple using first fix base.
Screen (Earth) must be continuous along entire length of loop.
2. First fix base is fixed to mounting surface using
2 fixing holes.
3. Cable entry can be rear or side.
4. Connections are to connector block on main
sounder body.
5. Main body is then fastened onto base, using
4 allen head screws (supplied).

Product Codes
Code Description
MAS850LPS Intelligent addressable internal wall sounder
MAS850LPSWP Intelligent addressable weatherproof wall sounder

80
Intelligent Addressable Product Range

Wall Sounder Beacons MASB860 and MASB860WP

MASB860WP weatherproof wall sounder beacon MASB860 internal wall sounder beacon

Overview Features
The Menvier intelligent addressable wall sounder MASB860
beacon has been developed specifically to operate • Loop powered
with the latest generation of Menvier intelligent • Combined sounder beacon
• High efficiency design
addressable control panels.
• Selectable tones controlled by
the panel
The high efficiency design offers excellent sound • Adjustable volume controlled
output levels despite the low current consumption. by the panel
Whilst also includes a high powered LED beacon to
provide both audible and visual alarm signals.
MASB860WP
internal base • Weatherproof version (IP66)
MASB860 • Loop powered
The Menvier MASB860 is designed for wall mounting, • Combined sounder beacon
has a choice of different tones and volume levels, a • High efficiency design
built in short circuit isolator and is soft addressed for • Selectable tones controlled by
ease of installation. the panel
• Adjustable volume controlled
MASB860WP by the panel
The Menvier MASB860WP is IP66 rated so suitable
for external and wash down areas, it designed for
wall mounting, has a choice of different tones and Benefits
volume levels, a built in short circuit isolator and is
• Low current
soft addressed for ease of installation.
• High efficency audio / visual
unit suitable for DDA
compliance
weatherproof base

81
Intelligent Addressable Wall Sounder Beacons - MASB860 and MASB860WP

Dimensions Technical Specification


Code MASB860 MASB860WP
Description Internal wall sounder beacon Weatherproof wall sounder beacon
Standards EN54 Pt3 EN54 Pt3
Specification
Operating Voltage 17V dc to 32V dc 17V dc to 32V dc
Standby Current < 320μA < 320μA
Tones (set by panel) Continuous: 984Hz Continuous: 984Hz
Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz
Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle
Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap
Internal Weatherproof Sound Output @ +/-3dB Low volume: 92dB at <6.5mA Low volume: 92dB at <6.5mA
wall sounder beacon wall sounder beacon (set by panel) Medium volume: 97dB at <7.5mA Medium volume: 97dB at <7.5mA
High volume: 100dB @ <8.5mA High volume: 100dB @ <8.5mA
Flash Energy 1Hz 1Hz
Description H (mm) W (mm) D (mm) Environmental
Internal 105 105 95 Operating Temperature -10°C to +55°C -10°C to +55°C
Weatherproof 108 108 103 Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH
Physical
Construction PC/ABS PC/ABS
Colour Red Red
Lens Colour Red Red
Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm
Weight 0.21kg 0.32kg
Ingress Protection IP42 IP66
Cable Entry Rear/side Rear/side
Cable Size / Type 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC
Compatibility
Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems

Standard Connection Installation System Functionality


MASB860 / MASB860WP MASB860 MASB860 / MASB860WP
1. Installation is simple using first fix base. 1. Volume is set by fire control
Screen

Screen

2. First fix base is fixed to mounting surface using panel, no need to access
OUT

2 fixing holes. sounder to alter setting.


IN

3. Cable entry can be rear or side. 2. Tone is set by fire control


E - + E - + 4. Connections are to connector block on main. panel, no need to access
LOOP

LOOP

Compatible Menvier
OUT

sounder body. sounder to alter setting.


IN

Intelligent Addressable
Control Panel 5. Main body is then clipped into position on
mounting base, body locks into position when
WARNING: pressed home.
Do NOT use high voltage testers if ANY equipment is
connected to the system. MASB860WP
1. Installation is simple using first fix base.
Screen (Earth) must be continuous along entire length of loop.
2. First fix base is fixed to mounting surface using
2 fixing holes.
3. Cable entry can be rear or side.
4. Connections are to connector block on main
sounder body.
5. Main body is then fastened onto base, using
4 allen head screws (supplied).

Product Codes
Code Description
MASB860 Intelligent addressable internal wall sounder beacon
MASB860WP Intelligent addressable weatherproof wall sounder beacon

82
Intelligent Addressable Product Range

Loop Connected LED Beacon MAB870

MAB870 loop connected LED beacon

Overview Features
The Menvier intelligent addressable loop connected • High efficiency design
LED beacon is available to complement audible • LED technology
• Low profile design
alarms for use in areas either where people may be
present who have impaired hearing or areas with
high ambient noise levels. Benefits
• Low current
The Menvier MAB870 is designed for both wall and
• High efficency LED / visual
ceiling mounting, has a built in short circuit isolator
unit suitable for DDA
and is soft addressed for ease of installation.
compliance

83
Intelligent Addressable Loop Connected LED Beacon - MAB870

Dimensions Technical Specification


Code MAB870
Dia (mm) D (mm) Description Loop connected LED beacon
95 53 Specification
Operating Voltage 17V dc to 32V dc

D
Standby Current < 250μA
Alarm Current < 4.1mA
Flash Frequency 1/2Hz
Environmental
Dia
Operating Temperature -10°C to +55°C
Humidity (Non Condensing) 0 to 95% RH
Physical
Construction PC/ABS
Colour Red
Dimensions (Dia x D) 95mm x 53mm
Weight 0.15kg
Ingress Protection IP54
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Standard Connection Installation System Functionality


MAB870 1. Installation is simple using first fix base. 1. Utilises multiple LED's
2. First fix base is fixed to mounting surface via combined with careful optical
2 fixings holes. design to provide high intensity
Screen

Screen

OUT

3. Cable entry is from the rear. flash with low current


IN

4. Connections are to connector block on beacon consumption.


E - + E - + body. 2. Low profile design for discreet
LOOP

LOOP

Compatible Menvier 5. Beacon body is pressed into first fix base then installation.
OUT
IN

Intelligent Addressable
Control Panel twisted to lock into position.

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Screen (Earth) must be continuous along entire length of loop.

Product Codes
Code Description
MAB870 Intelligent addressable loop connected LED beacon

84
Intelligent Addressable Product Range

4 Way Sounder Controller Unit MPU424

MPU424 4 way sounder controller unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Avoids the need to wire
conventional sounders back
providing solutions for most design requirements.
to the main panel
• 4 separate sounder circuits
The MPU424 4 way sounder controller unit is a loop
(0.4A)
connected interface, which provides the facility to
• All outputs are independently
power and control 4 independent conventional
programmable
sounder circuits. This greatly simplifies installation in
• Battery backup via integral
applications where specialist sounders or beacons
battery
are required by avoiding the need to connect them
• Built in short circuit isolator
directly to the intelligent addressable control panel.
• Built in power supply
The unit only uses a single address yet each circuit
can be independently controlled according to the Benefits
required cause and effect programming.
• Plug and play, no hard
addressing required
• Increased system integrity
• No external short circuit
isolator required
• Beacon and strobe can be
wired direct to the interface
thereby saving time and
cabling
• Reduce cost of installation

85
Intelligent Addressable 4 Way Sounder Controller Unit - MPU424

Dimensions Technical Specification


D H (mm) W (mm) D (mm) Code MPU424

300 300 74 Description 4 channel sounder controller unit


Standards EN54 Pt4 & Pt17 2005
Specification
Operating Voltage 24V dc
H
Quiescent Current 250μA
Mains Supply Voltage 230V ac
Mains Current Consumption 0.4A
Battery 2 x 12 V, 4Ah, SLA
Standby Period 24 hours + 30 minutes ringing
Sounder Circuit Output 0.4A (max)

W Sounder Load 1.6A (max)


Fire Relay Switching Voltage 30V dc
Switching Current 1A (resistive), 0.5 A (inductive) (max)
Environmental
Operating Temperature -10ºC to +45ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction ABS/steel
Dimensions (H x W x D) 300mm x 300mm x 74mm
Weight 5.4kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. The sounder controller interface requires a local
unswitched 230V supply and incorporates a back
up battery to maintain functionality under mains
failure conditions.
2. Cable entry can be top or rear.
3. Top entry is via 20mm conduit entries (pre-fitted
with blanking plugs for unused entries).
4. Rear entry via substantial cable slot in metal back plate
5. Top cover secured with tamper resistant screws

Standard Connections
6K8 6K8 6K8 6K8

intelligent addressable loop

230V ac mains

FIRE RELAY
N/O C N/C

L N E E + - E + - E + - E + - E - + E - +
OUT IN

+
+
BATT
back up
- battery
-

NOTES:
1. Earth (Screen) cable must be connected to its adjacent earth terminal.
2. The end of line resistor must always be fitted, even if input is not used.
3. Sounder circuits are monitored for wiring open and short circuit.
4. Output fire relay is a set of changeover volt free-contacts and is not monitored.
5. This unit should only be finally connected to the 230V ac mains supply and battery,
during system commissioning.

Product Codes
Code Description
MPU424 4 way sounder controller unit

86
Intelligent Addressable Product Range

Zone Monitor Unit MIU871

MIU871 zone monitor unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Accepts a zone of Menvier
conventional detector heads
providing solutions for most design requirements.
and callpoints (detectors must
be connected via the Cooper
The MIU871 zone monitor unit connects zones
CDBB300 mounting base)
of suitable conventional detectors.
• Only takes a single address
• Input monitored for open, short
circuits and ground trouble
• Built in short circuit isolator

Benefits
• Plug and play no hard
addressing required
• Easy to expand a system using
existing wiring
• No external short circuit
isolator required

87
Intelligent Addressable Zone Monitor Unit - MIU871

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MIU871

88 147 60 Description Zone monitor unit

W Standards EN54 Pt17 & Pt18 2005


Specification
Operating Voltage 18V dc to 30 V dc
Quiescent Current 2.8mA
Alarm Current 8mA
H Current with 20 Detectors 3.4mA
D
Detector Load 20 detectors per zone (max)
Callpoint Load Unlimited
Environmental
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 88mm x 147mm x 60mm
Weight 0.23kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. Zone monitor unit is fixed to a deep double gang
back box (supplied).
2. All connections are via heavy duty terminals.
3. Cable entry can be top, bottom, side or rear.
4. Can be surface or semi recessed mounted.

Standard Connections
EOLM-1

6K

- OUT +
- IN +
intelligent addressable loop
- OUT+
- IN +

E - + E - + E - + E - +

OUT IN CALLPOINT DETECTOR


LOOP ZONE ZONE

Callpoints can be connected with detectors on detector zone if preferred

NOTES:
1. Earth (Screen) cable must be connected to its adjacent earth terminal.
2. The end of line resistor must always be fitted, even if input is not used.
3. Maximum spur length - see BS5839 Pt:1 2002 for zone coverage.
4. There is no maximum number of conventional callpoints allowed per zone output.
5. Unit can only be used with its respective Cooper fire systems and compatible sensor and base.

Note: The MIU871 accepts a zone of Menvier Product Codes


conventional detector heads (detectors must
be connected via the Cooper CDBB300 Code Description
mounting base) MIU871 Zone monitor unit

88
Intelligent Addressable Product Range

Shop Monitor Unit MSU840

MSU840 shop monitor unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Accepts a zone of Menvier
conventional detector heads
providing solutions for most design requirements.
and callpoints (detectors must
be connected via the Cooper
The MSU840 shop monitor unit is designed to
CDBB300 mounting base)
enable small units with conventional fire detection to
• Provides 2 conventional
be fully integrated with a main intelligent addressable
sounder circuits
fire system. It is ideal for applications such as
• Only takes a single address
connecting individual shop units into a main
• Includes output changeover
shopping centre system. An external power supply is
relay
required to drive the 2 conventional sounder circuits.
• Inputs monitored for open,
This power supply must be regulated for fire and
short circuits and ground
current limited.
trouble

Benefits
• Plug and play no hard
addressing required
• Easy to expand a system using
existing wiring
• No external short circuit
isolator required
• Reduced installation cost by
using the 2 sounder circuits

89
Intelligent Addressable Shop Monitor Unit - MSU840

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MSU840

88 147 60 Description Shop monitor unit

W Standards EN54 Pt17 & Pt18


Specification
Operating Voltage 15V dc to 30V dc
Quiescent Current 3.4mA (max)
Quiescent Load Current 2.8mA (max)
H Alarm Current 8mA (max)
D
Zone Circuits
Number Input Circuits 2
Zone Circuit 1 Callpoints only
Zone Circuit 2 Detectors and Callpoints
Number of Callpoints Unlimited
Callpoint Resistance 470Ω to 680Ω
Zone Circuit 1 EOL 6K8
Zone Circuit 2 EOL Active EOL
Number of Detectors 20 (max)
Short Circuit Fault Threshold 150Ω
Open Circuit Fault Threshold N/A active EOL
Sounder Circuits
Number of Sounder Circuits 2
Load per Output 300mA (max)
Sounder Circuit 1 and 2 EOL 12K
Relay
Fire Relay Single Pole C/O 1A - 30V dc
Environmental
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 88mm x 147mm x 60mm
Weight 1kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Standard Connections
24V dc output
EOLM-1 power supply unit
FAULT CONTACT 24V
6K8 12K 12K
N/O O/P

- Out +
- In +
- +
12K
intelligent addressable loop
- Out +
- In +

E - + E - + E - + E - + N/O C N/C + - + - E - +

OUT IN + - E + - 24V
CALLPOINT DETECTOR EXTERNAL
LOOP ZONE ZONE 1 2 PSU EXTERNAL
SOUNDER MONITOR PSU
INPUT
FIRE RELAY

callpoints can be connected with detectors on detector zone if preferred

Note: The MSU840 accepts a zone of Menvier Product Codes


conventional detector heads (detectors must
be connected via the Cooper CDBB300 Code Description
mounting base) MSU840 Shop monitor unit

90
Intelligent Addressable Product Range

Spur Isolator Unit MSI850

MSI850 spur isolator unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Allows a spur of intelligent
addressable devices to be fed
providing solutions for most design requirements.
from the main loop
• Integral short circuit isolators
The MSI850 spur isolator unit enables a spur of
for the loop and the spur
intelligent addressable devices to be connected to a
• Automatically controls
main analogue loop, the device is designed to
addressing sequence
simplify installation of remote parts of buildings or for
• Built in short circuit isolator
simple system extensions.

Benefits
• Plug and play no hard
addressing required
• Easy to expand a system using
existing wiring
• Reduced installation cost
• No external short circuit
isolator required

91
Intelligent Addressable Spur Isolator Unit - MSI850

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MSI850

88 147 60 Description Spur isolator unit

W Standards EN54 Pt17 2005


Specification
Quiescent Current 170μA
Environmental
Operating Temperature -10ºC to +60ºC
H Humidity (non condensing) 0 to 95% RH
D
Physical
Construction PC/ABS
Dimensions (H x W x D) 88mm x 147mm x 60mm
Weight 0.23kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. Please refer to current edition of BS5839-1 for
details of the maximum allowable area to be
covered by a single zone.
2. Spur isolator unit is fixed to a deep double gang
back box (supplied).
3. All connections are via heavy duty terminals.
4. Cable entry can be top, bottom, side or rear.
5. Can be surface or semi recessed mounted.

Standard Connections

OUT

+
intelligent
addressable loop no end of line
E resistor required
m
IN
SPUR
+
+

NOTES:
1. Earth (Screen) cable must be connected to its adjacent earth terminal.
2. For maximum spur length/load see BS5839 Pt1:2002.
3. Unit can only be used with its respective Cooper fire systems and compatible sensor and base.

Product Codes
Code Description
MSI850 Spur isolator unit

92
Intelligent Addressable Product Range

3 Channel I/O Unit MIO324

MIO324 3 channel I/O unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Soft addressed
• 3 separate inputs and 3
providing solutions for most design requirements.
separate outputs
• Inputs monitored for open and
The MIO324 3 channel I/O unit enables simple
short circuits
interfacing between the fire system and other
• Integral short circuit isolator
equipment such as nurse call systems or access
control systems. The inputs are fully monitored for
open and short circuits. Benefits
• Plug and play no hard
addressing required
• Built in short circuit isolator no
additional hardware required
• Unit takes 3 inputs, 3 outputs
- only 1 address required to
monitor and control saving on
equipment and installation

93
Intelligent Addressable 3 Channel I/O Unit - MIO324 and MIO324T

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MIO324

88 147 60 Description 3 channel I/O unit

W Standards EN54 Pt17 & Pt18 2005


Specification
Operating Voltage 18V dc to 30V dc
Quiescent Current 310μA
Maximum Switching Voltage 50V ac or 30V dc
H Output Relay Contact Rating 1A at 30V resistive, 0.5A inductive
D
Environmental
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 88mm x 147mm x 60mm
Weight 0.23kg
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. 3 Channel input output unit is fixed to a deep
double gang back box (supplied).
2. All connections are via heavy duty terminals.
3. Cable entry can be top, bottom, side or rear.
4. Can be surface or semi recessed mounted.
5. Relay contacts are rated at 24V dc 1A.

Standard Connections

5K6 5K6 5K6

22K 22K 22K


intelligent
addressable loop

OUTPUTS
E - + E - + - + - + - + N/O C N/C N/O C N/C N/O C N/C

IN OUT INPUTS
LOOP

NOTES:
1. Earth (Screen) cable must be connected to its adjacent earth terminal.
2. The end of line resistor must always be fitted, even if input is not used.
3. Input circuit is monitored for wiring open and short circuit.
4. Output relay is a set of changeover volt free-contacts and is not monitored.

Product Codes
Code Description
MIO324 3 channel I/O unit
MIO324S 3 channel I/O unit, resets on silence
MIO324T 3 channel I/O unit, contains 3 separate addresses

94
Intelligent Addressable Product Range

230V ac Relay Unit MIO1240

MIO1240 relay unit

Overview Features
An extensive range of interfaces are available to • Quick and simple to install
support the Menvier range of control panels, • Soft addressed
• Only takes a single address
providing solutions for most design requirements.
• Integral short circuit isolator
The MIO1240 230V ac relay unit enables simple
interfacing between the fire system and other Benefits
equipment such as nurse call systems or access
control systems. • Plug and play no hard
addressing required
The ability of the output unit to switch mains also • Easy to expand a system using
makes the unit ideal for plant control or mains existing wiring
powered door holders. • No external short circuit
isolator required
The input is monitored for open and short circuits
therefore can be used for fire input applications such
as monitoring sprinkler flow switches.

95
Intelligent Addressable - 230V ac Relay Unit - MIO1240

Dimensions Technical Specification


D H (mm) W (mm) D (mm) Code MIO1240

129 180 60 Description 230V ac relay unit


Standards EN54 Pt17 & Pt18 2005
Specification
Operating Voltage 18V dc to 30V dc
H
Quiescent Current 310μA
Maximum Switching Voltage 250V ac or 30V dc
Maximum Switching Current 8A
Environmental
W
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 129mm x 180mm x 60mm
Weight 0.6kg
Ingress Protection IP65
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. Mains rated input relay is designed for surface
fixing.
2. All connections are via heavy duty terminals.
3. Cable entry can be top, bottom or side.
4. Output relay contacts are rated at 230V ac.

Standard Connections

5K6

intelligent addressable loop 22K

volt-free output 230V rated

E - + E - + - + E C N/C N/O

IN OUT
SPUR INPUT

NOTES:
1. Earth (Screen) cable must be connected to its adjacent earth terminal.
2. The end of line resistor must always be fitted, even if input is not used.
3. Input circuit is monitored for wiring open and short circuit.
4. Output relay is a set of changeover volt free-contacts and is not monitored.

Product Codes
Code Description
MIO1240 230V ac relay unit

96
Intelligent Addressable Product Range

Micro Zone Monitor Unit MIU872

MIU872 micro zone monitor unit

Overview Features
An extensive range of micro interfaces are available • Quick and simple to install
to support the Menvier range of control panels, • Accepts a zone of Menvier
conventional detector heads
providing solutions for most design requirements.
and callpoints (detectors must
be connected via the Cooper
The MIU872 is a single zone input, soft addressed,
CDBB300 mounting base)
micro interface, incorporating integral short circuit
• Only takes a single address
isolators.
• Input monitored for open and
short ground trouble
It is fully compatible with the current range of Menvier
• Active end of line monitoring
intelligent addressable fire detection panels.
• Built in short circuit isolator
It is suitable for interfacing a zone of up to 20
conventional Menvier detectors onto a Menvier Benefits
intelligent addressable control panel.
• Plug and play no hard
It will operate with any Menvier conventional detector addressing required
in configuration with a schottky diode type base. • Easy to expand a system using
existing wiring
• No external short circuit
isolator required

97
Intelligent Addressable Micro Zone Monitor Unit - MIU872

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MIU872

65 35 18.5 Description Micro zone monitor unit


Standards EN54 Pt17 & Pt18
Specification
D
Operating Voltage 18V dc to 30V dc
Quiescent Current 2.6mA (nom)

H
Load With 20 Detectors,
W
and Unlimited Callpoints 3.2mA (nom)
Alarm Load With 20 Detectors,
and Unlimited Callpoints 8.0mA (nom)
Detector Zone
Mounting Details Detectors per Zone 20 (max)
End of Line Monitor Active end of line unit - EOLM-1
Fire Input Trigger Resistance 680Ω (nom)
Short Circuit Fault
Threshold Resistance 100Ω (max)
Open Circuit Fault
22mm

Threshold Resistance 39KΩ (min)


Environmental
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 65mm x 35mm x 18.5mm
Weight 0.28kg
37.5mm
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. Suitable for use with any Menvier conventional detector.
2. Connections suitable for single strand fireproof cable up.
to 2.5mm2.
3. Loop and output cable screen must be connected to
interface earth terminals.

Note: No addressing of the interface is required


(see control panel operation for details)

Standard Connections
EOLM-1

IN+

IN-

EARTH LOOP IN

maximum 20 Cooper conventional detectors INPUT


LOOP OUT

Note: The MIU872 accepts a zone of Menvier Product Codes


conventional detector heads (detectors must
be connected via the Cooper CDBB300 Code Description
mounting base) MIU872 Micro zone monitor unit

98
Intelligent Addressable Product Range

Micro Single Channel Output Units MCOM

MCOM-R micro single channel output unit MCOM micro single channel output unit

Overview Features
An extensive range of micro interfaces are available • Quick and simple to install
to support the Menvier range of control panels, • Compact size
• Soft Addressed
providing solutions for most design requirements.
• Integral short circuit isolator
The MCOM is a single output, soft addressed, micro
interface, incorporating integral short circuit isolators. Benefits
It is extremely compact and therefore ideal for
incorporation into other equipment. • Plug and play no hard
MCOM-S addressing required
The MCOM is fully compatible with the current range • No external short circuit
MCOM-S micro single channel output unit isolator required
of Menvier intelligent addressable fire control panels.

It is suitable for switching low voltage (24V dc at 1A


maximum), via a set of non latching relay contacts.

It is suitable for switching HVAC control circuits, plant


shutdown control circuits, fire door closure etc.

Optional Variants

The MCOM-R gives a 5 second pulse on reset.

The MCOM-S is identified by the panel as a sounder.


Dose not reset on silence, resets on reset only.

99
Intelligent Addressable Micro Single Channel Output Units

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MCOM

65 35 18.5 Description Micro single channel output unit


Standards EN54 Pt17 & Pt18
Specification
D
Operating Voltage 18V dc to 30V dc
Quiescent Current 310μA

H
Output Relay
W
Switching Voltage 24V dc to 30V dc
Contact Rating 1A
Switching Power 30 Watts
Environmental
Mounting Details Operating temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 65mm x 35mm x 18.5mm
Weight 0.078kg
22mm

Ingress protection IP40


Compatibility
Suitable for use with Menvier intelligent addressable fire systems

Installation
1. Suitable for switching 24V dc control circuits
37.5mm
(fire door retainers etc).
2. Connections suitable for single strand fireproof
cable up to 2.5mm2.
3. Loop and output cable screen must be connected
to interface earth terminals.
4. The relay output is a set of change over,
non-latching, volt free contacts which are non
monitored.

Note: No addressing of the interface is required


(see control panel operation for details)

Standard Connections

N/O

N/C
LOOP IN
C

OUTPUT LOOP OUT

Product Codes
Code Description
MCOM Micro single channel output unit (recognised as output unit)
MCOM-S Micro single channel output unit (recognised as sounder)
MCOM-R Micro single channel output unit (5 second reset pulse)

100
Intelligent Addressable Product Range

Micro Single Channel Input Units MCIM

MCIM-NF micro single channel output unit MCIM micro single channel output unit

Overview Features
An extensive range of micro interfaces are available • Quick and simple to install
to support the Menvier range of control panels, • Compact size
• Soft Addressed
providing solutions for most design requirements.
• Integral short circuit isolator
The MCIM is a single input, soft addressed micro
interface, incorporating integral short circuit isolators. Benefits
It is extremely compact and therefore ideal for
incorporation into other equipment. • Plug and play no hard
addressing required
The MCIM is fully compatible with the current range • No external short circuit
MCIM-C micro single channel output unit isolator required
of Menvier intelligent addressable fire control panels.

It is suitable for monitoring a set of normally open,


volt free contacts such as sprinkler system flow
switches, auxiliary panel fire/fault signals as well as
non fire input signals such as flow valve open
contacts, generator start up, fire door closed etc.

Optional Variants

The MCIM-NF is designed for non-fire applications.

The MCIM-C is identified by the panel as a callpoint.

101
Intelligent Addressable Micro Single Channel Input Units

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MCIM

65 35 18.5 Description Micro single channel input unit


Standards EN54 Pt17 & Pt18
Specification
D
Operating Voltage 18V dc to 30V dc
Quiescent Current 310μA

H
Inputs
W
Trigger Resistance 5K6Ω
End of Line Resistor 22KΩ
Short Circuit Fault
Threshold Resistance 1KΩ
Mounting Details Open Circuit Fault
Threshold Resistance 33KΩ
Environmental
Operating temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
22mm

Construction PC/ABS
Dimensions (H x W x D) 65mm x 35mm x 18.5mm
Weight 0.078kg
Ingress protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems

37.5mm
Installation
1. Inputs monitored for open and short circuit fault
conditions.
2. Suitable for monitoring normally open volt free contacts
(flow switches etc).
3. Connections suitable for single strand fireproof cable up
to 2.5mm2.
5. Loop and output cable screen must be connected to
interface earth terminals
6. The end of line monitoring resistor, must always be fitted
at the end of the input wiring, if the input is unused the
end of line resistor must be fitted at the interface input
terminals.

Note: No addressing of the interface is required


(see control panel operation for details)

Standard Connections

5K6
IN+

IN-
22K
EARTH LOOP IN

INPUT
LOOP OUT

Product Codes
Code Description
MCIM Micro single channel input unit (recognised as input unit)
MCIM-C Micro single channel input unit (recognised as callpoint)
MCIM-NF Micro single channel input unit (non fire input)

102
Ancillaries and Test Equipment

Heavy Duty Relay Unit MAR724

MAR724 heavy duty relay

Overview Features
The Menvier heavy duty relay unit is designed for • Simple to install
interfacing heavy loads such as door release units • Visible status indication LED
• Double pole change over
or plant shut down equipment with fire alarm
contacts
systems.

It is simple to fix and install and the neat unobtrusive Benefits


design makes it suitable for use in a wide range of
• Low current consumption
areas.
• 230V ac rated contacts
• Will switch up to 10A (resistive)
The heavy duty relay is powered by 24V dc external
supply and is provided with 2 separate sets of
changeover contacts. The front mounted status LED
illuminates when relay is energised.

103
Heavy Duty Relay Unit - MAR724

Dimensions Technical Specification


H (mm) W (mm) D (mm) Code MAR724

89 150 58 Description Heavy duty relay unit

W Specification
Coil Rating 24V dc 10mA
Contact Rating 10A at 240V ac or 30V dc
Contacts 2 x sets of changeover contacts
Environmental
H Operating Temperature -10°C to +55°C
D
Humidity (Non Condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 89mm x 150mm x 58mm
Weight 0.24Kg
Ingress Protection IP30
Compatibility
Suitable for use with Menvier fire systems

Standard Connection Installation


MAR724 1. Heavy duty relay unit fixes to a standard deep
double gang back box (supplied).
RELAY 1 RELAY 2
2. Cable entry is via back box, cables are terminated
into heavy duty terminals on relay PCB.

Interface Options
NC C NO NC C NO + -
1. Relay is powered by an external 24V dc supply.
Compatible Menvier
24V dc OUTPUT
Control Panel

WARNING:
Do NOT use high voltage testers if ANY equipment is
connected to the system.

Product Codes
Code Description
MAR724 Heavy duty relay unit

104
Ancillaries and Test Equipment

Power Supply Unit FX1A

FX1A power supply unit

Overview Features
The FX1A is a 24V dc battery backed power supply • Compact enclosure
unit complete with back up batteries. • Integral battery
• Fault indicator
• Remote fault contact
The output is continuous and transition from mains to
battery is without break in the output. It is monitored
and has local fault indication as well as volt free Benefits
contacts for remote fault signalling, making it ideal as
a general purpose power supply for fire alarm • Simple to use
applications. • Secure steel enclosure
• Built in battery back up

105
Power Supply - FX1A

Dimensions Technical Specification


D W
H (mm) W (mm) D (mm) Code FXA1

230 323 77 Description Power supply unit


Standards EN54 Pt4
Specification
Maximum Continuous Load 0.8A
H
Maximum Intermittent Load 1.0A
Standby Batteries 2 x 12V 2.1 Ah
Fault Relay Contact Rating 3A at 24V dc
Fuse Protection Mains input, charger output, system output
Output Voltage (mains healthy) 27.5V dc
Output Voltage (mains failed) 20.4 - 24V dc dependant on battery status
Physical
Construction Mild steel
Dimensions (H x W x D) 230mm x 323mm x 77mm
Ingress Protection IP30
Compatibility
Suitable for use with Menvier fire systems

Installation System Functionality


1. Enclosure is designed for wall mounting. 1. FX1A power supply provides a
2. 2 x 20mm knockouts are provided for cable entry maximum output of 1A.
at the top of the enclosure. 2. Output is used to supply any
3. A fused terminal block is provided for mains connected load and also to
supply connection. recharge the integral batteries.
4. Output is protected by internal 1.5A fuse. 3. To enable batteries to be
charged correctly maximum
continuous external load
should not exceed 0.8A.
4. LED indicators are provided to
signify:
• Mains healthy
• System fault
• Output supply fault
• Charger output fault
5. Mains healthy and system fault
LED's are visible without
removing front cover.

Product Codes
Code Description
FX1A 24V dc power supply unit, with battery backup
FASP0429 24V dc power supply unit, no battery backup

106
Ancillaries and Test Equipment

Loop Tester Kit LP800KIT

LP800KIT loop tester kit in box LP800KIT loop tester

Overview Features
The LP800 loop tester is a hardware / software • Pre-addressing: Identifies all
combination that can be used to test, commission Menvier field devices and
determines their address and
and fault find a loop of up to 200 Menvier intelligent
device type
addressable devices (sensors, sounders, ancillary • Analogue Values: Constantly
devices) without having to connect the loop to the displays in real time the
Menvier intelligent addressable fire panel. analogue value of all Menvier
loop devices in order to
The loop tester is connected between the loop and determine their status
PC. It allows the engineer to quickly identify and • Test LED: This command
LP800KIT loop tester kit box locate any loop device that is operating outside its operates the LED of any
operating conditions by varying the alarm threshold inputs (detector/call points) as
of any loop device (alarm, prealarm and fault). well as controls the outputs of
sounders and output modules
The loop tester hardware requires a free serial port on • Device Settings: Analogue
the PC, either internal or via a USB extension, a values of all devices can be
mains power supply and a direct connection to the interpreted according to
device loop. ranges which can be set and
altered by the user (OK, pre-
alarm, fire)
• Event Log: A history of events
can be stored from the date
the application was started
• Soft addressing: Automatically
assigns a new, and potentially
different, address to every
Product Codes device found on the loop

Code Description
LP800KIT Programmer

107
Ancillaries and Test Equipment

Addressable Device Programmer CF800PROG

CF800PROG programmer, back

CF800PROG addressable device programmer

Overview Features
The CF800PROG programmer is a versatile tool to • Reads addresses
aid the installation, commissioning, maintenance • Writes addresses
• Reads analogue values
and servicing of current addressable devices and
• Tests devices
fire alarm systems. • Deletes addresses
• Programmes the 3 heat
This unit is light, robust and easy to operate using a settings
user friendly menu structure on 2 x 40 character LCD
display. It is powered from a single PP3 size, heavy
duty battery or an external supply.

The programmer has a built in addressable base as


well as two external terminals for use with all other
current addressable ancillary devices.

Product Codes
Code Description
CF800PROG Addressable device programmer

108
Notes

109
Notes

110
Global Presence Cooper Industries
Cooper Industries is a diversified global manufacturer
of world-class electrical products, components and
Environmental Policy
tools, with 2009 revenues of $4.5 billion. The
Company has seven operating divisions with On May 1, 1990, Cooper Industries issued a formal policy to affirm its
manufacturing facilities in 23 countries, and employs commitment to the environment. The principles of this policy, reinforce
more than 25,000 people throughout the world. standards of operation already in place and remind employees
throughout the world that environmental considerations have the highest
With its broad range of products and global brands priority at Cooper.
including; Bussmann electrical and electronic fuses;
Crouse-Hinds and CEAG explosion-proof electrical
equipment; Halo, Metalux, Menvier and Crompton
mains and emergency luminaires; Kyle and McGraw-
Edison power systems products; Menvier and JSB
fire systems, Cooper is uniquely positioned for
several long-term growth trends, including the current
The Carbon
global infrastructure developments, improvements to
enhance the reliability and productivity of the electric
grid, the increased demand for energy-efficient
Trust Standard
products and the need for improved electrical safety.
In 2010 the UK facilities of Cooper Industries have been awarded the
Carbon Trust Standard after taking action on climate change by
measuring, managing and reducing its carbon emissions by 17%. The
Carbon Trust Standard recognises organisations for real carbon
reduction. Based on a rigorous, independent assessment, it certifies that
Principles organisations have measured, managed and reduced their carbon
emissions across their own operations, and are committed to reducing
them year on year.
• To observe all environmental laws and regulations
• To respond effectively to environmental concerns
involving Cooper facilities and products
• To minimize and, wherever possible, to eliminate
the generation of all wastes
• To conduct operations in a manner that
demonstrates respect for the environment
• To cooperate with federal, state and local
governments in developing scientifically based
environmental standards
• To encourage the development of environmentally
sound procedures and to conduct business with
the best-available technology
• To maintain environmental monitoring programs
that ensure compliance with governmental
requirements and these principles
• To provide training programs that emphasize the
individual's responsibility for sound environmental
decisions

In line with this global policy Cooper Lighting and


Safety Ltd has an Environmental Management Policy
which satisfies the requirements of
BS EN 14001:2004
Cooper Safety Fire Systems Sales Service
Cooper Lighting and Safety Ltd T: +44 (0)1302 303 999 T: +44 (0)1302 303 352
Wheatley Hall Road F: +44 (0)1302 303 333 F: +44 (0)1302 303 332
Doncaster E: sales@cooperfire.com E: service@cooperfire.com
South Yorkshire
DN2 4NB Technical and Quotations Export
United Kingdom T: +44 (0)1302 303 350 T: +44 (0)1302 303 344
F: +44 (0)1302 303 332 F: +44 (0)1302 303 345
www.cooperfire.com E: techsupport@cooperfire.com E: export@cooperfire.com

Conditions of sale
All goods supplied are subject to the company’s general conditions of sale which are available on request.

Trade Descriptions
All descriptions represent only particulars of the goods
to which they apply and do not form part of any contract. The company reserves the right to change specification
without prior notification or public announcement.

®2011 Cooper Lighting and Safety


All rights reserved.

Publication reference: CFS0018_UK_R1

The trade names and brand names contained herein are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the
Cooper Trademarks without the prior written consent of Cooper Industries.

Cooper Industries plc


600 Travis, Suite 5600
Houston, TX 77002 - 1001
T: 713 - 209 - 8400
www.cooperindustries.com