Professional Documents
Culture Documents
Page
1 Introduction ......................................................... 3
2 Application .......................................................... 4
9 Glossary............................................................. 39
Part. C - 9600 LSY compact 3x1+1 Part. B - 9600 LSY compact 2x1+1
terminal regenerator configuration. terminal WMSN configuration.
Figure 2. 9600 LSY
S T M -1 U SER M ODEM T R A N S C E IV E R
I N T /R S T
S T M -1 U SER M ODEM T R A N S C E IV E R
M ODEM T R A N S C E IV E R
OMSN REGENERATOR
7X STM-1 or 140 or 3x45 or 3x34 or 63x2 Mb/s
MODEM TRANSCEIVER
REGENERATOR WMSN
INTERFACES
STM-1 STM-0 STM-1 STM-0
STM-1 ELECTRICAL G.708 X X X X
(STM-1 sub-equipped) (STM-1 sub-equipped)
STM-1 OPTICAL S1.1 G.957 X X X X
(STM-1 sub-equipped) (STM-1 sub-equipped)
STM-1 OPTICAL L1.1 G.957 --- --- X ---
STM-1 OPTICAL L1.2 G.957 --- --- X ---
140 Mbit/s G.703 --- --- X ---
3 x 45 Mbit/s G.703 --- --- X X
(1 x 45 Mbit/s)
3 x 34 Mbit/s G.703 --- --- X X
(1 x 34 Mbit/s)
63 x 2 Mbit/s G.703 --- --- X X
(21 x 2 Mbit/s)
Table 1. 9600 LSY user interfaces
SML
1354NN
NML
1354RM
SNML
TSD-IM
SEN-IM
1353SH
EML
QB3
TSD-IM
ECT TSD-IM ECT ECT ECT
F F F
TRANSCEIVER
IF TX
RF TX
IF TX TRANSMITTER
RF
TX L.O.
DC/DC
CONVERTER
RX L.O.
IF RX RF RX
IF TX RECEIVER
RF
In the left side of the shelf the system common units are
accommodated: the system controller (SC), the service channel unit.
The channel-depending units are built by the modem units and the
RRA units.
REGENERATOR
RRA BOARD MODEM BOARD
TX
STM1 ELET./OPT. HTL RFCOH MODEM
MODEM RT
RRA
INTERFACE SW RX
AUX.
SERV. ATPC DCCR
V batt. DC/DC
CONVERTER
OS
ECT
WMSN
1650 SM- C REGENERATOR ASSEMBLY
STM-1 MODULE
63x2 Mbps
3x34 Mbps
ELECT. HTL RT
3x45 Mbps VC STM1 RRA RFCOH MODEM
INT. SW
140 Mbps MATRIX
- ATPC
155 Mbps
SERVICE UNIT
SERV. WST
EOW & AUX &
Aux. 2x2
Serv. Ch. ATPC
Mbps
SYSTEM DC/DC V
CONTR. CONV. batt.
F QB3
ECT OS
Note: in case of channel plan with homopolar channel space 28 MHz, the threshold value is 0,5dB
higher
Note: in case of channel plan with homopolar channel space 28 MHz, the threshold value is 0,5dB
higher
RADIO SYSTEM 9640 LSY 9647 LSY 9667 LSY 9611 LSY
RF FREQ. BAND (GHz) 3.6-4.2 4.4-5.0 6.4-7.1 10.7-11.7
(*) Tolerance: ± 0.5 dB at ambient temperature; : ± 1.5 dB at in temperature range –5°C to +55 °C
(**) Guaranteed values
RADIO SYSTEM 9640 LSY 9647 LSY 9667 LSY 9611 LSY
RF FREQ. BAND (GHz) 3.6-4.2 4.4-5.0 6.4-7.1 10.7-11.7
(*) Tolerance: ± 0.5 dB at ambient temperature; : ± 1.5 dB at in temperature range –5°C to +55 °C
(**) Guaranteed values
Electrical Interface
• 155.520 Mb/s (STM-1) ITU-T Rec. G.703
• 139.264 Mb/s (PDH) ITU-T Rec. G.703
• 3 x 34.368 / 3 x 44.736 Mb/s ITU-T Rec. G.703
• 2.048 Mb/s ITU-T Rec. G.703
Optical Interface
• 155.520 Mb/s (STM-1) ITU-T Rec.G.957– G.958
Note: the three type of optical interfaces above mentioned are available for Multiplex assembly
while only the S 1.1 type is available for Regenerator assembly.
Auxiliary Channels
• 1 x 2 Mb/s (STM-1 ONLY)
Service channel
• Omnibus voice channel (E1) DTMF
• 6 x 64 Kb/s (G.703 or V11)
• 1 x 9.6 Kb/s RS 232
Network Management
• F. interface RS 232 C
• Q3 interface Ethernet AUI 10 Base2, 10 BaseT
• QECC interface D1÷D3 / D4÷D12
Rack dimensions (h x w x d)
• 2200 x 600 x 300 (mm)
Environment
• EMI-EMC ETS 300385 Class B
• Safety IEC 950 and IEC 215
• Temperature range:
Standard version: -5°C to +55°C (with fans)
Compact version: -5°C to +50°C (without fans)
-5°C to +55°C (with fans)
Power Supply
– 48 to –60 Vdc (± 20%)
_________________________________________________________
Note: all data subject to change without notice.
Via Trento 30
200059 Vimercate (MI)
Italy
Alcatel reserves the right to modify the specifications in this document without prior warning, as a result of
technical upgrades or new regulations.