You are on page 1of 1

New method of managing pipe wall thickness

Traditional method: one detail text per each schedule.

From PDMS 12.0 onwards, Piping Specifications have a new Pipe Data Table concept:

So we can create just one parametric detail text containing new pseudo-attributes:

• For Tube elements:

Rtext ( 'ANSI B36 10 PE SMLS PIPE ' + ATTRIB SCHED )

i.e. ANSI B36 10 PE SMLS PIPE STD

Rtext ( 'ANSI B36 10 PE SMLS PIPE ' + STR (P1 WALL) + 'mm' )

i.e. ANSI B36 10 PE SMLS PIPE 6.02mm

• For Reducer elements:


Rtext ( 'REDU CONC ANSI B16.9 BW ' + ATTRIB SCHED OF OWN OF ATWREF + ' x ' + ATTRIB SCHED OF OWN
OF LTWREF )

i.e. REDU CONC ANSI B16.9 BW STD x XS

Rtext ( 'REDU CONC ANSI B16.9 BW ' + STR (P1 WALL) + 'mm x ' + STR (P2 WALL) + 'mm')

i.e. REDU CONC ANSI B16.9 BW 6.02mm x 5.08mm

• For Tee elements:

Rtext ( 'TEE ANSI B16.9 BW ' + STR (P1 WALL) + 'mm x ' + STR (P3 WALL) + 'mm')
i.e. TEE ANSI B16.9 BW 6.02mm x 5.08mm