You are on page 1of 2

A 3 hour drawdown test was conducted in which the rate during the first hour averaged 478,5 STB/D;

during the
second hour, 319 STB/D; and during the third hour, 159.5 STB/D. Following table gives the flowing BHP’s measured
during the test. Estimate permeability and skin factor.
Other data are:
Pi= 3000 psi; B=1,2 RB/STB; viscosity= 0,6 cp; porosity: 12%; h= 10 ft; Ct= 48*10-6 psi-1; rw= 0,25 ft.

t pwf qn (pi-pwf)/qn Σ 7
0.000 3000.0
0.333 999.0 478.5 4.18181818 -0.4775558 6
0.667 857.0 478.5 4.47857889 -0.1758742
1.000 778.5 478.5 4.64263323 0 5

2.000 1378.5 319 5.0830721 0.45154499


4
2.333 2043.0 159.5 6 1.45646983
2.667 2067.5 159.5 5.84639498 1.23200761 3
3.000 2094.0 159.5 5.68025078 1.13033377
2

0
-1 -0.5 0

Pi 3000
B 1.2
Viscosidad 0.6
Porosidad 0.12
h 10
C 0.000048
rw 0.25
5 STB/D; during the
wing BHP’s measured

0,25 ft.

0
-1 -0.5 0 0.5 1 1.5 2

x y
P1 0 4.64263323
P2 0.45154499 5.0830721

m' 0.97540417
b' 4.64263323

k(md) 12.0024092
s 0.28186534

You might also like