The Maxitherm Coal Watertube Boiler is a
Maxitherm-developed integrated design that
provides excellent safety and reliable steam
generation. This boiler is designed to operate
with a wide range of fuels from the high volatile
low ash coal to the high ash low volatile coals.
Coal
Longer Boiler Life Span
Maxitherm Coal Watertube Boiler has a high heat-
ing surface area, this allows for a lower level of ther-
mal stress on the heating surfaces for the same
amount of heat transfer. As a result, our boiler has
a longer life span.
Maximum Safety Management
Maxitherm have developed a maximum safety
boiler with protected steam drum, combustion
controls, flame failure safeguards, a modulating
feed water system, a dual low water security
system and twin water pumps.
Superheater Autoventing
During startup phase of Maxitherm Coal Watertube
Boiler, an automatic mechanism vents our
superheater to prevent it from overheating.
Fast Response to Steam Demand
The faster natural circulation and stable waterline
produced by our unheated downcomer allows our
boiler to respond quickly and effortlessly when
your plant requires steam quality.
Drier Steam Output
The large drum volume of Maxitherm Boiler
increases the steam / water interface. This reduces
the level of water entrainment, resulting in drier
steam quality.
Longer Tube Life Span
D type construction minimises the number of tube
bends and allows the use of large radius tube
bends, this reduces bending stress on the tubes
and increases their life span.
Complete Combustion
Maxitherm Coal Watertube Boiler has a gas tight
combustion chamber made possible by membrane
walls that are seal welded. This prevents hot gas
leaking or cold air infiltration to allow for more
complete combustion.
Low Maintenance
The Maxitherm Boiler is designed with complete
membrane water wall construction, thus eliminat-
ing the use of internal refractories that require high
maintenance and replacement cost.
Maximum Heat Transfer
All convection tubes are arranged in a staggered
design to ensure that the whole circumference area
of tube is effective heating area for maximum heat
transfer,
Better Handling of Fluctuation in Steam Load
This large drum volume also increases the available
steam space, hence increases the ability of our
boiler to handle steam load fluctuations.
WY Cia aeT ana
Product General Arrangement
Hl
Hci
we cn
Hill
i
i
i
Hy
a
Note: The above diagram is a representation, Actual drawings will vary accordingly.
Product Range
Coe) lairclerass bamaniy Sets Era)
cr 5; nts
rons) Seta i oe ot
8000 768 5906 2885 5320 15850
8000) ms2 4786 3590 5920 22110
10000 1538 6046 3590 5920 30610
15000 2051 7700. 4230 5920 37850
15000 2308 8330) 4230 5920 ‘40800
18000 2820 9590) 4230 5920 48000
20000 3077 9545) 6140 5920) 49300
23000 3353 wos 6140 5920 ‘53800
25000 3846 eee 6140 5920, 62800
28000 102 10785 6140 5920 73500
"30000 4618: 1835 6140 5920 182300
"33000 4871 12255 6140 5920 ‘86000
35000 5128 12780 6140 5920 ‘20400
Note: The above data is for representative purpose and is no
‘omprehensive. For further information, please contact us