You are on page 1of 2
The Maxitherm Coal Watertube Boiler is a Maxitherm-developed integrated design that provides excellent safety and reliable steam generation. This boiler is designed to operate with a wide range of fuels from the high volatile low ash coal to the high ash low volatile coals. Coal Longer Boiler Life Span Maxitherm Coal Watertube Boiler has a high heat- ing surface area, this allows for a lower level of ther- mal stress on the heating surfaces for the same amount of heat transfer. As a result, our boiler has a longer life span. Maximum Safety Management Maxitherm have developed a maximum safety boiler with protected steam drum, combustion controls, flame failure safeguards, a modulating feed water system, a dual low water security system and twin water pumps. Superheater Autoventing During startup phase of Maxitherm Coal Watertube Boiler, an automatic mechanism vents our superheater to prevent it from overheating. Fast Response to Steam Demand The faster natural circulation and stable waterline produced by our unheated downcomer allows our boiler to respond quickly and effortlessly when your plant requires steam quality. Drier Steam Output The large drum volume of Maxitherm Boiler increases the steam / water interface. This reduces the level of water entrainment, resulting in drier steam quality. Longer Tube Life Span D type construction minimises the number of tube bends and allows the use of large radius tube bends, this reduces bending stress on the tubes and increases their life span. Complete Combustion Maxitherm Coal Watertube Boiler has a gas tight combustion chamber made possible by membrane walls that are seal welded. This prevents hot gas leaking or cold air infiltration to allow for more complete combustion. Low Maintenance The Maxitherm Boiler is designed with complete membrane water wall construction, thus eliminat- ing the use of internal refractories that require high maintenance and replacement cost. Maximum Heat Transfer All convection tubes are arranged in a staggered design to ensure that the whole circumference area of tube is effective heating area for maximum heat transfer, Better Handling of Fluctuation in Steam Load This large drum volume also increases the available steam space, hence increases the ability of our boiler to handle steam load fluctuations. WY Cia a eT ana Product General Arrangement Hl Hci we cn Hill i i i Hy a Note: The above diagram is a representation, Actual drawings will vary accordingly. Product Range Coe) lairclerass bamaniy Sets Era) cr 5; nts rons) Seta i oe ot 8000 768 5906 2885 5320 15850 8000) ms2 4786 3590 5920 22110 10000 1538 6046 3590 5920 30610 15000 2051 7700. 4230 5920 37850 15000 2308 8330) 4230 5920 ‘40800 18000 2820 9590) 4230 5920 48000 20000 3077 9545) 6140 5920) 49300 23000 3353 wos 6140 5920 ‘53800 25000 3846 eee 6140 5920, 62800 28000 102 10785 6140 5920 73500 "30000 4618: 1835 6140 5920 182300 "33000 4871 12255 6140 5920 ‘86000 35000 5128 12780 6140 5920 ‘20400 Note: The above data is for representative purpose and is no ‘omprehensive. For further information, please contact us

You might also like