Capacity (for 1.8mm dia. @ 25mm c/c with 250 grade steel)
For 350mm wall , wall area per m strip Ast, wall 350000 mm^2
(Tensile Stress
Allowable tensile stress in 350mm wall σt, allowable 0.052 Mpa allowable)
For 350mm wall , wall area per m strip Ast, wall 230000 mm^2
(Tensile Stress
Allowable tensile stress in 350mm wall σt, allowable 0.079 Mpa allowable)
Capacity (for 2.2 mm dia. @ 50mm c/c with 415 grade steel)
For 350mm wall , wall area per m strip Ast, wall 350000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.066 Mpa
For 350mm wall , wall area per m strip Ast, wall 230000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.101 Mpa
Capacity (for 3mm dia. @ 50mm c/c with 415 grade steel)
For 350mm wall , wall area per m strip Ast, wall 350000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.123 Mpa
For 350mm wall , wall area per m strip Ast, wall 230000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.187 Mpa
Capacity (for 4.75mm dia. @ 150mm c/c with 415 grade steel)
For 350mm wall , wall area per m strip Ast, wall 350000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.113 Mpa
For 350mm wall , wall area per m strip Ast, wall 230000 mm^2
Allowable tensile stress in 350mm wall σt, allowable 0.172 Mpa
CAPACITY TABLE
WALL 1X
(In plane loading)
Stress S22 (Mpa) S11 (Mpa)
(Near Opening) 0.58 0.745
(Corner) 0.43 0.430
Combination: (0.7DL-Eqy)
Wall 2X 4.82 3.06 1.76 L/ 1364 OK
5.94 3.12 2.82 L/ 851 OK
6.52 3.1 3.42 L/ 702 OK
6.4 3.07 3.33 L/ 721 OK
5.92 3.19 2.73 L/ 879 OK
4.97 3.19 1.78 L/ 1348 OK
Combination: (DL+LL-Eqy)
Wall 1Y 5.05 3.125 1.925 L/ 1247 OK
Wall 2Y 7.27 3.16 4.11 L/ 584 OK
Wall 3Y 7.411 3.17 4.241 L/ 566 OK
Wall 4Y 6.85 3.21 3.64 L/ 659 OK
Wall 5Y 7.3 3.23 4.07 L/ 590 OK
Wall 6Y 5.21 3.267 1.943 L/ 1235 OK
Check for the diaphragm action due to connectivity in slab and wall
The shear stress of wall and slab interface = 0.1 N/mm2
Shear strength of the wall = 0.2068 N/mm2
As earthquake force can be higher than the design level earthquake the interface must be
stronger than
The wall for full load transfer from diaphragm to wall
Remaining shear stress = 0.2068-0.1= 0.1068 N/mm2
The bars going through the slab from vertical splint should have capacity to resist this shear
Shear strength of bar = 0.4fy= 0.4*415= 166 N/mm2
No of bars = 6 from inside and 6 from outside
Resisting shear force = (6*2*50)*166/1000= 99.6 KN
Shear resisting capacity = 99.6*1000/ 1273050 = 0.0782 N/mm2< 0.1068 N/mm2, not
satisfying the shear transfer from diaphragm to wall.
Add 1-8 mm dia extra cut piece bar through diaphragm
Additional bars = 6 nos
Total nos of bars =18 nos
Resisting shear force = (6*3*50)*166/1000= 149.4 KN
Shear resisting capacity = 149.4*1000/ 1273050 = 0.117 N/mm2> 0.1068 N/mm2, satisfying the shear transfer from diaphr
0.1 Mpa
1X