Professional Documents
Culture Documents
EN 2-5
Free-swing
slide channel
door closer
in Contur design
DORMA TS 99 Free-swing slide channel
door closer
2 TS 99 FL/FLR, GB
DORMA TS 99 FL
506,5
31 428
23
106
16 11 16
18 18
71
4
52
93 200
64 160
413
DORMA TS 99 FLR
785
52 430 69 131 29 64
16 11 16
18 18
71
106
23
31 428
441
DORMA TS 99 FLR-K
823
40 428
30
115
16 11 16
18 18
71
4
52
93 200
64 160
413
TS 99 FL/FLR, GB 3
DORMA TS 99 FL Hold-open device
with free-swing function
32 150 428
34
65
42
72
16
120
110
78
175
24 V DC
142 160
450
171 200 ø 8 24 V DC
78
max. 7
36
42
84
23
41,5
27,5
11
150 428
143 441
175
4 TS 99 FL/FLR, GB
1 2 3 4 5
DORMA TS 99 FLR Hold-open device
TS 99 FLR with
TSfree-swing
99 FLR-K function TS 99 GSR-EMR TS 93 GSR-EMR/BG RMZ
TS 93 EMR TS 93 GSR-EMR
min.10
min.10
min.10
min.10
min. 10
min.10
504 126,5
78
max. 7
7
36
84
41,5
23
30
11
150 428
min.10
min.10
min.10
min.10
min. 10
143 441
min.10
175
1 2 3 4 5
S 99 FLR TS 99 FLR-K TS 99 GSR-EMR TS 93 GSR-EMR/BG RMZ
TS 93 EMR TS 93 GSR-EMR
min.10
min.10
min.10
min.10
40 125
5
5
30
43
65
42
72
71
120
110
16
78 4
52
min.10
min.10
min.10
min.10
24 V DC 171 200
142 160
min.10
TS 99 FL/FLR, GB 5
DORMA TS 99 FL Application
on double doors
The modular TS 93 GSR operable and is not automa- The system operates inde-
system also enables the use tically closed, which facili- pendently of the door closer
of the TS 99 FL EN 2-5 on tates access in doors located hydraulics using a push rod
the active leaf of double in heavily frequented areas. clamping arrangement with
doors. As the door is opened, The GSR system ensures protective overload release.
the free-swing function is the closure of double doors The door release/closer
activated from an opening in the correct sequence: activator mechanism is inte-
angle of > 0° at the active first the inactive leaf then grated in the slide channel.
leaf. The door remains freely the active leaf.
43
leaf then the active leaf. It (e.g. DORMA RMZ in the
4
also facilitates the combined Contur design).
TS 93 B
hold-open of both door DORMA RM-N units can 84
leaves. The inactive leaf can also be connected as a 142 160
be held at an angle between second and third detector.
80° and 130°, and the With adjustable pull-off
active leaf is held open at force (no tools required),
any angle up to max. 150° the hold-open can also be
by the door co-ordinator. readily released by hand.
Note: The hold-open point
Inactive leaf
of the inactive leaf is always Minimum width 370 mm
located at the maximum in the case of unequal leaves
door opening angle – install
a door stop at this position.
DORMA TS 99 FL GSR-EMR 1
6 TS 99 FL/FLR, GB
Ø8 (24 V DC)
115 470
34
120
78
110
TS 99 FL
160 142
24 V DC
1350 – 2500
Active leaf
min.10
444 470
250 34
31 95
2,5
2,5
120
110
TS 99 FL
Ø10 (230 V AC) Ø8 (24 V DC)
78
160 142
24 V DC
1700-2500
Active leaf
TS 99 FL/FLR, GB 7
DORMA TS 99 Application examples
Hold-open system
RM-N
230 VAC
RM-N
RMZ
2 x 121 KΩ 2 x 121 KΩ
TS 99 FL
1 234 1 234
C C
B - B -
T + T +
HT
- -
A A
12 3 11 10 2 14
7 8 9 16 1 4
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
RM-N
2 x 121 KΩ 2 x 121 KΩ
TS 99 FLR
1 234 1 234
C C
B - B -
HT
T + T +
- -
A A
12 3 11 10 2 14
7 8 9 16 1 4
12 4 1
N PE L 230 V AC
± 10%
121 KΩ TS 99
FLR
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
8 TS 99 FL/FLR, GB
DORMA TS 99 FLR-K + 2x RM-N
RM-N
230 VAC
RM-N
2 x 121 KΩ 2 x 121 KΩ
TS 99 FLR-K
1 234 1 234
C C
B - B -
T + T +
HT - -
A A
12 3 11 10 2 14
7 8 9 16 1 4
N PE L 230 V AC
± 10%
121 KΩ TS 99
FLR-K
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
RM-N
230 VAC
RM-N
GSR-EMR
2 x 121 KΩ 2 x 121 KΩ
TS 99 FL TS 93
B - B -
T + T +
- -
A A
12 3 11 10 2 14
7 8 9 16 1 4
N PE L 230 V AC
± 10%
121 KΩ
TS 93
GSR-EMR
Recommended cabling:
I - Y (St) Y 2 x 2 x 0,6
TS 99 FL/FLR, GB 9
DORMA RMZ Smoke detectors
DORMA RM-N
The DORMA RMZ in the issued by the German Data and features RMZ RM-N
Contur design and DORMA Institute for Building Techno-
Functions Smoke detector 2 2
RM-N smoke detectors pro- logy and ensure perfect
Release device 2 –
vide the ideal complement interaction between all Power supply unit 2 –
to the DORMA TS 99 FL the devices employed for
Smoke Scattered light principle
system for passive/preventive holdingopen fire and smoke detection (optical sensor) 2 2
fire protection. check doors – whatever the
Fixing Lintel or
They are designed in accor- situation.
transom-mounted 2 –
dance with the latest codes Ceiling-mounted – 2
Connection of other detectors 2 –
Total installed load (max.)
for hold-open device and
DORMA RMZ other detectors in W 9,8 –
The DORMA RMZ smoke for both further detectors Power consumption of
detector in the Contur design and for an external manual internal detectors in W 1,2 0,65
provides a 24V DC supply release device are also provi- LED Alarm 2 2
for all the hold-open devices ded. The unit is available in indicators Standby 2 –
connected to it. the RMZ version with a sta- Maintenance due 2 –
Contaminated 2 –
In the event of an alarm or bilised power pack, or in the
power failure, it de-energises RMZ DCW version without a Input voltage 230 V AC 24 V DC
± 10 % +15 %, –10%
the devices (release function). power pack for integration in
Output voltage 24 V DC –
It has an automatic reset building management and
Detector operating voltage 24 V DC 24 V DC
which can be switched to control systems via a DCW +15 %, –10 %
manual mode if required. bus and the DORMA TMS Input current (max.) in mA 75 20
A floating (no-volt) change- door management system. Floating (no-volt) change-over contact 24 V 30 V
over contact and connections Safety extra low voltage (SELV) AC/DC AC/DC
2 A 1A
Reset Automatic 2 2
378 30
Can be changed
to manual reset 2 –
34
357,5
Functional check Smoke detection 2 2
Connection terminals
for external manual release 2 –
Degree of protection IP 30 IP 43
Ambient temperature in °C –20, +40 –10, +60
Weight in kg 0,25 0,15
Dimensions Length 379
in mm Overall depth 34 ø 100
Height 30 44
min.10
DORMA RM-N
The DORMA RM-N smoke with smoke evolution. It can
detector ensures the early be connected to all DORMA
detection both of smoul- hold-open systems.
dering fires and open fires
F Approval certification
DORMA RMZ in the
Contur design and DORMA
Ø 100
RM-N smoke detectors have
been granted general building
approval by the German
44
10 TS 99 FL/FLR, GB
Hold-open systems Regulations/Information
The use of hold-open systems The regulations and instruc- Further information can – General building regula
is subject to special tions provided below are be found in the following tions pertaining to the
regulations based on offi- intended as an aid, pursuant documents: approval of the hold-open
cial approval requirements. to statutory regulations that – Richtlinien für Feststell system concerned
These relate in particular apply e.g. in Germany, to anlagen des Deutsches – EN 1155
to the final inspection ensure that all participants Instituts für Bautechnik, – DIN EN 14637
(acceptance), continuous are properly informed of the Berlin
monitoring and maintenance. most important requirements [Code of practice relating
that relate to the installation to hold-open systems
and operation of hold-open issued by the German
systems. Institute for Building
Technology, Berlin]
1. General
1.1 In the case of fire doors pipes, stored/deposited goods 1.3 Each hold-open device used, a pushbutton must be
(and similar shutters/closures/ or components (e.g. false must also be capable of being provided to facilitate manual
barriers) that are held open by ceilings or other overhead released by hand, without release.
hold-open systems, the sweep items/elements) are reliably adversely affecting the The manual release push
area necessary for the closing prevented from falling into functional capabilities of the buttons employed for this
operation must be kept the sweep area. automatic release device. purpose must be red and
constantly clear. This area 1.2 Wherever possible, In the case of door closers carry the wording “Close
must be clearly identified smoke detectors should be with electro-magnetic Door” or equivalent. The
by lettering, floor markings used for hold-open systems. hold-open, the manual release pushbutton must be located
or similar. Where necessary, For hold-open systems may be performed by a small in the immediate vicinity of
structural measures must also for fire doors in emergency tug applied to the door leaf. the door and must not be
be implemented to ensure escape routes, smoke If holding electro-magnets or concealed by the door when
that cables, leads, lines, detectors must be used. free-swing door closers are this is held open.
2.1 In Germany and countries turers of monitoring and/or in the immediate vicinity of 2.3 The operator is to be
governed by DIN regulations: hold-open devices, skilled the door, a plate supplied by provided with a certificate
Following on-site installation personnel authorized by same, the manufacturer of the detailing the successful
of the operable hold-open or skilled personnel from an hold-open system measuring acceptance inspection; this
system, its functional integrity accredited inspection agency. 105 mm x 52 mm and certificate must be retained
and quality of installation must 2.2 In Germany and countries carrying the inscription by the operator.
be confirmed by an accep- governed by DIN regulations: Hold-open system
tance inspection procedure. Once the acceptance inspec- Inspected by... (company
The acceptance inspection tion has been successfully logo with month and year
may only be performed by completed, the operator shall of acceptance inspection)
skilled personnel of manufac- permanently fix on the wall or equivalent
3. Periodic surveillance
3.1 The hold-open system 3.2 In addition, the operator and to carry out or instigate 3.3 The scope, result and
must be kept by the operator is obliged at least once a adequate maintenance. The time of the periodic
in a constantly good year, or at shorter intervals associated test, inspection inspection are to be
operating condition, and if specified in the approval and the maintenance work recorded. These records
inspected at least once a certificate, to inspect all the may only be performed by must be retained by the
month to ensure that it is devices to ensure that they an expert or an appropriately operator.
functioning properly. are operating and interacting trained person.
properly and without fault,
TS 99 FL/FLR, GB 11
DORMA TS 99 Standard equipment
and accessories
G-SR
64102001
G-SR-EMF 1
64112001
G-SR-EMR 1
64215001
RMZ
smoke detector
# #
648000xx
RM-N
smoke detector
# #
64830000
Manual release pushbutton
HT-UP 35901531
# #
HT-AP 35901532
12 TS 99 FL/FLR, GB
TS 99 FLR TS 99 FLR-K TS 99 FL door closer TS 93 B Cushioned
door closer body door closer body body, Leaf-fixed door closer body limit stay
Size EN 2-5 Size EN 2-5 Size EN 2-5 Size EN 2-5
yY
542903xx
#
yY
543001xx
#
1x 1x
y y
Y
1x 1x
y y
Y
1x 1x
y y
# # #1)
# # #
# # #
TS 99 FL/FLR, GB 13
DORMA TS 99 Specification texts
DORMA RMZ
Smoke detector in the Contur manual release devices are Model Colour
design, with standby and provided. Y RMZ with integrated Y Silver
maintenance due indicators, Can be switched to manual power pack. Power supply Y White (sim. to RAL 9106)
integral power pack and reset. One-piece cover. 230V AC, operating vol- Y Stainless steel “Design”
optical smoke sensor for Overall height 30 mm. tage 24V DC Y Special colour
transom/lintel fixing. For General building approval Y RMZ DCW. Smoke detec- (sim. to RAL ____)
release activation of DORMA granted by DIBt, Berlin, for tor without power pack for
hold-open devices. A floating use in a hold-open system. connection to DCW bus. Make
(no-volt) alarm contact Acceptance inspection of Y Optional integral alarm mo- DORMA RMZ
and connections for further the system is mandatory in dule adding an audible sig- DORMA RMZ DCW
detectors and external Germany. nal to the visual indicator.
DORMA RM-N
Optical smoke detector, General building approval Colour
24V DC, for ceiling fixing. granted by DIBt, Berlin and Y White (sim. to RAL 9106)
For use as second and third the VdS, Cologne; compliant
triggering detector on all to EN 54, Part 7.
DORMA hold-open systems. Acceptance inspection Make
With floating (no-volt) mandatory in Germany. DORMA RM-N
change-over contact.
14 TS 99 FL/FLR, GB
DORMA TS 99 FL EN 2-5 GSR
Slide channel door closer on Slide channel with integral Approved by the German Model
the active leaf, compliant with mechanical door coordinator, Institute for Building Y Leaf-fixed/pull side
EN 1154, with CE mark, in compliant with EN 1158. Technology, Berlin, for use (TS 99 FL on active leaf,
the Contur design, for door This system operates inde- in a hold-open system. TS 93 on inactive leaf)
widths up to 1250 mm, with pendently of the door closer Acceptance inspection man-
electro-hydraulic hold-open hydraulics using a push datory in Germany. Colour
complaint with EN 1155, and rod clamping system with a Y Silver
with a free-swing function from protective overload release Y White (sim. to RAL 9106)
a door opening angle of > 0°. and one-piece cover. Overall Y Stainless steel “Design”
Closing speed and latching height 30 mm. Y Special colour
action adjustable. Non-handed. (sim. to RAL ____)
Non-handed. Cam-action door closer on the
Operating voltage 24V DC. inactive leaf: TS 93 EN 2-5. Make
DORMA TS 99 FL GSR
TS 99 FL/FLR, GB 15
www.dorma.com
South America
DORMA Door Controls Pte. Ltd. DORMA Sistemas de Controles
Room 701, Technology Plaza para Portas Ltda.
651 King’s Road Av. Piracema, 1400
North Point
· Subject
France UK/Ireland
DORMA France S.A.S. DORMA UK Ltd.
Zone Europarc Wilbury Way
Immeuble Mega 42 Hitchin
44 021226