Professional Documents
Culture Documents
th rough and
g e t
ta
hr
an
ou
adv
gh
R®”
ow i n
F 02/E/08.06/10/BRO
TO
gt
AC
o
th F
e “H
IGH BAK ING
Tonality_GB.qxd 01.08.2006 14:45 Uhr Seite 2
2
Tonality_GB.qxd 01.08.2006 14:45 Uhr Seite 3
3
Tonality_GB.qxd 01.08.2006 14:46 Uhr Seite 4
When creative
cladding design is
soaring to the sky…
4 03
Tonality_GB.qxd 01.08.2006 14:46 Uhr Seite 5
5
Tonality_GB.qxd 01.08.2006 14:46 Uhr Seite 6
6
Tonality_GB.qxd 01.08.2006 14:46 Uhr Seite 7
The “TONALITY®”
technology advantage:
7
Tonality_GB.qxd 01.08.2006 14:47 Uhr Seite 8
“TONALITY®”-“CLASSIC” – “CLASSIC”–
enhanced quality. creative colour design
made to last.
pilaster strip
Natural surfaces:
The illustrations of the colour shades can only be considered a reference as printed colours can
never be true reproductions of the original colours and do not reflect the richness of the tiles.
8
Tonality_GB_2007.qxd 12.04.2007 8:42 Uhr Seite 9
“TONALITY®”– “TONALITY®”–
the new dimension in creative format.
format and color.
쎲 = Standard
쑗 = on request 150 x 400 mm to 300 x 1,200 mm
(Special formats on request)
400 mm
150 mm
9
Tonality_GB.qxd 01.08.2006 14:51 Uhr Seite 10
th
AL
ru o
1,200 °C. For an overall quality of each
“ K ER
gh
and every cladding tile – in the trusted
CREATON roofing quality.
”
ow
R®
i
gt
TO
n
ot C
he “ FA
H I G H BA K I N G
11
Tonality_GB.qxd 01.08.2006 14:52 Uhr Seite 12
“TONALITY®”-“COLOR” – “COLOR”–
creative color diversity. limitless imagination.
Standard production formats of the “TONALITY” - “COLOR” collection is 175 x 400 and 200 x 400mm
(other formats on application).
FA FC FE FF FH
12
Tonality_GB.qxd 01.08.2006 14:53 Uhr Seite 13
FK FN FP FS FW
colours can never be true reproductions of the original colours and do not reflect the
The illustrations of the colour shades can only be considered a reference as printed
These shown surfaces are glazed.
13
Tonality_GB.qxd 01.08.2006 14:53 Uhr Seite 14
Vertikale primary
sub-construction
closed joint profile see approval open joint profile see approval end profile for border see approval
no: dwg 200-06, joint 9 mm no: dwg 200-13, joint 9 mm no: dwg all-01
no protection against dismantling
14
Tonality_GB.qxd 01.08.2006 14:54 Uhr Seite 15
Horizontal primary
sub-construction
closed joint profile see approval open joint profile see approval end profile for border see approval
no: dwg 200-06, joint 9 mm no: dwg 200-13, joint 9 mm no: dwg all-01
no protection against dismantling
15
Tonality_GB.qxd 01.08.2006 14:54 Uhr Seite 16
Convincing arguments.
A minimal construction height can be realized starting from The RIVCLINCH connection and jointing technique used in
a construction height of 26 mm. As this is a perfect advan- this context has been proving its worth in aircraft and
tage in the renovation of façades, it will help you reduce the vehicle construction for some time now as a high-tech
depth and thus avoids costly connections and reveals. The connection of bearing and joint profiles. It stands for hig-
installation works on site are reduced as well: Joint and bea- hest safety and durability, offering clear advantages com-
ring profile are tightly connected to each other already by pared with the conventional connections:
the manufacturer. This guarantees a faster installation and
is thus time and cost saving. ● Higher resistance than with conventional techniques
● Premachining and finishing are not required
● The damaging of the surface of coated materials is
Vertikale primary
herewith avoided.
sub-construction
Detail – agraffe
closed Joint for hanging up the cladding tiles
Fuge 9 mm wide
safety device
optionally with activated protection
against dismantling
pressure part
for a better adjustment
16
Tonality_GB.qxd 01.08.2006 14:54 Uhr Seite 17
17
Tonality_GB.qxd 01.08.2006 14:55 Uhr Seite 18
18
Tonality_GB.qxd 01.08.2006 14:55 Uhr Seite 19
2. Building preparation
The highest possible degree of off-site prefabrication –
away from the building site – will provide optimal prepa-
ration. With the “TONALITY” system, the schedule will be
absolutely flexible. Installation will not be affected by
weather conditions at any time.
3. Installation
Time is money and “TONALITY” installation is quick. Due
to it’s sophisticated construction – and thus only few
anchorage points – the work involved for the positioning
and drilling of the boreholes is reduced considerably. Tile
bodies are inserted without any additional retaining
clamps. Insert them and there you are!
4. Maintenance
If you decide in favour of “TONALITY” you eliminate unde-
sired maintenance costs from your future planning. As
the high-quality CREATON façade requires low maintenan-
ce and is dirt-repellent. Even repairs or the entire redesign
are a simple matter. Each cladding tile can be individually
exchanged by non-destructive means.
19
Tonality_GB.qxd 01.08.2006 14:55 Uhr Seite 20
32 260 mm
52 mm
150 mm
27 450 mm
40 mm
20
Tonality_GB.qxd 01.08.2006 14:55 Uhr Seite 21
Certified Warranty.
● building regulations for “TONALITY” cladding system
approved according to DIN 18516 through the
German Institute for Building Technology (DIBt) in
Berlin
Plant Weroth/Rhineland-Palatinate
● production of the cladding tiles in accordance with
“TONALITY” is produced in
the Quality Management System DIN EN ISO 9001 and Werk II
the most modern plants of
Environmental Management System DIN EN ISO Werk I Europe.
14001 Werk III
21
Tonality_GB.qxd 01.08.2006 15:07 Uhr Seite 22
22
Tonality_GB.qxd 01.08.2006 15:07 Uhr Seite 23
23
Tonality_GB_2007.qxd 12.04.2007 8:42 Uhr Seite 24