NOMENCLATURE FOR SPECIFICATIONS IN TENDERS AND BOQ’S

(1) GLASS FIBER for CONCRETE


FOR ALL TYPE OF CONCRETE/RCC WORK LIKE SLAB, PCC/RCC
ROAD, PODIUM SLAB AND SPECIAL CONCRETE LIKE INDUSTRIAL
FLOORING etc:
GLASS FIBERS (KDMFIBER MAKE or eqv) OF 12MM LENGTH SHALL
BE HOMOGENEOUSLY MIXED WITH CONCRETE @ 85 GM/50KG
WEIGHT OF CEMENT OR 600GM/QUBIC METER OF CONCRETE FOR
RMC APPLICATIONS.

(2) GLASS FIBER for PLASTER


FOR OUT SIDE PLASTER AND ALL WEATHER EXPOSE PLASTER
WORK: GLASS FIBERS (KDMFIBER MAKE or eqv) OF 6 MM SHALL
BE HOMOGENOULSY MIXED WITH MORTAR @ 60GM/50KG
WEIGHT OF CEMENT.

(3) GLASS FIBRE MESH 200MM FOR JOINTS


BETWEEN ALL JUNCTIONS OF COLUMNS /BEAMS/ (RCC
MEMBERS) AND MASONARY WALLS 200 MM WIDTH CONMEHS
200MM (KDM MAKE or eqv) MADE FROM GLASS YARN SHOULD BE
FIXED WITH CEMENT PASTE BEFORE PLASTERING THE
JUNCTIONS.

(4) GLASS FIBRE MESH 142MM FOR CONCEALED AREA


(FOR WATER PIPE AND ELECTRIC WIRE)
FOR ALL CONCEALED AREAS OF WALL CONMEHS 142MM (KDM
MAKE or eqv ) MADE FROM GLASS YARN SHOULD BE FIXED WITH
CEMENT PLASTE BEFORE PLASTERING THE MASONRY AREA.