You are on page 1of 4

Friction Loss along a pipe

Test Volume Time h1 h2 T Vel v Re ΔP f Q


# (ml) (s) (mm) (mm) (°C) (m/s) (m2/s) (m) (m3/s)
1 10 19.22 433 374 19.9 1.30855 1.007E-06 ### 0.059 0.029 0.000520
2 10 20.40 413 360 19.9 1.23286 1.007E-06 ### 0.053 0.029 0.000490
3 10 21.25 398 349 20 1.18355 1.005E-06 ### 0.049 0.029 0.000471
4 10 22.25 377 332 20.1 1.13036 1.002E-06 ### 0.045 0.029 0.000449
5 10 23.94 350 311 20.3 1.05056 9.975E-07 ### 0.039 0.029 0.000418
6 10 25.85 334 300 20.3 0.97294 9.975E-07 ### 0.034 0.030 0.000387
7 10 28.20 310 281 20.3 0.89186 9.975E-07 ### 0.029 0.030 0.000355
8 10 29.30 294 267 20.4 0.85838 9.951E-07 ### 0.027 0.030 0.000341
9 10 32.75 268 246 20.5 0.76795 9.926E-07 ### 0.022 0.031 0.000305
10 10 36.50 254 236 20.6 0.68905 9.902E-07 ### 0.018 0.031 0.000274

Apparatus Data:
Length 533.4 mm 0.5334 m ε from ε/D
Diameter 22.5 mm 0.0225 m
Area 0.000398
Friction factor VS Reynolds Number
0.033

0.032

0.031
Friction factor

0.030

0.029

0.028

0.027
14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000

Reynold's number