You are on page 1of 14
oO © + a o D a wi _ ELECTRICAL RESEARCH AND DEVELOPMENT ASSOCIATION (Accredited by the National Accretion Board forTesting end Callbration Laborstoriee, Gov.of nai) ERDA Road, Makarpura Industrial Estato, Vadodara-390 010, India, EPABX : 491 (0265) 2642942, 2642964, 2642377, 3043128 / 20/90/31 /33 Fax: 491 (0266) 2638982 E-mail: erda@erde.org Web: http:/www.erda.org caritetone Tom TEST REPORT SHEET NO.: 1 OF 11 NAME & ADDRESS OF CUSTOMER TEST REPORT NO.: RP-1617-027452 7 ‘ DATE + 13/09/2016 M/s. Engineers Enterprise CUSTOMER RERHOZINIC H-1010, + NO. Road No. 14, DATED 1 06/09/2016 V.K.LA., DATE OF SAMPLE DATE OF Jaipur (Raj.) - 302 013 | RECEIPT TESTING | 08/09/2016 12/09/2016 SAMPLE DESCRIPTION ‘SAMPLE IDENTIFICATION 66 kV, 1250 A, Double Break Isolator Serial No. : EE-02 without Earth Blade Rated Voltage 66 kV Type : Turn Twist Type Double HSV. 72.5 kV Break Type, without EB Rated Current 250A No. of Phase 203 Make : M/s. Engineers Enterprise Frequency 0 Hz Year of Mfg. 32016 ERDA Sample Code N Insulator Make __: M/s. Aditya Birla ERDA-00159292 aca TEST DETAILS TEST SPECIFICATION 1) Lightning Impulse Voltage Test IS ; 9921 (Part 4)-1985 2) Dry Power Frequency Voltage Test 3) Wet Power Frequency Voltage Test ENCLOSURE: DRG. No.: 1) EE-6601 2) EE-6608 3) EE-6607 TEST WITNESSED BY: REMARKS: The sample conforms to the requirement of above mentioned test specifications with respect to the tests carried out. k l Gots ee Ca A.S.KHOPKAR PREPARED BY CHECKED BY ___ APPROVED BY Note : 1. This report relates only to the particular sample recelved Ih Good condition for testing a ERDA 2. This report cannot be reproduced in part umtder any circumstances 3. Publication ofthis report requires prior permission in writing from Director, ERDA. 4, Only the tests asked for by the customer nave been carried out, 5. In case of any dispute, Vadodara wil be the exclusive jurisdiction & shall be construed as where the cause has arised ution: ERDA is not responsible for the authenticity of photocopied or reproduced test reports ERDA provides support to customers for verfication of the authenticity of test reports issued by ERDA ELECTRICAL RESEARCH AND DEVELOPMENT ASSOCIATION (Accrecitedby the National Accreditation Boarder Testing and Calibration Laboratories, Gevt.ot naa) ERDA Road, Makarpura Industral Estate, Vadodara-390 010, India. EPABX : +91 (0265) 2642042, 2642964, 2642977, 9049128 /29 / 90/31 /93 Fax: #91 (0265) 2638982 E-mail : erda@erda.org Web —: httpy/ww.erda.org [ TEST REPORT NO.: RP-1617-027452 SHEET NO.: 2 OF 11 DATE 3/09/2016 Impulse Vi (As per Cl. No. 3.1.6 of IS : 9921 (Part 4)-1985) Atmospheric Condition: Dry bulb temperature 2 30.0°C Wet bulb temperature } 25.50C Atmospheric Pressure 1751.1 mm of Hg Test Parameters: } © | rated vottage 2 66 kV Test Voltage : Close: 325 kVp 3% & Open: 375 kVp + 3% No. of Shots to be applied: 15 +ve & 15 -ve Polarity shots (for each test condition) ‘Test Observation: Calibration Pulse : 192.57 kVp Wave Shape 11.10 / 49.48 us No. of Shots Applied —_: Calibration Pulse, 15 +ve & 15 ~ve Polarity shots (For each test condition) No. of Shots recorded __: Calibration Pulse, First & Last Shot (For each test condition & both polarity) Test Test Voltage Applied Impulse | Earth : Conaition ‘applied | Connected | Switching _ IN KVP | Remarks | | 0. To To levice | “Positive | Negative | e@ |b Polarity | Polarity rF (322.64 to | (324.97 to | withstood ha BebeF | Closed | (ER SE TO | ey wath 2, (325.00 to | (324.94 to | withstood Bb ACacF Closed | eee | ee 3 (873.21 to | (375.35 to | withstood A au Open 375.35) _| 375.79. 4 (374.49 to | (375.44 to | withstood 7 7 Open | “375.31)_| 375.85) _ | (74.15 to | (875.45 to) withstood ae ees Open 375.90) | 375.83)_| a _ Open | 75:13 t2 | (375.16 £6] withstood i 375.69) 375.55) | Gow oe (PREPARED BY it CHECKED BY TE 1969492 ELECTRICAL RESEARCH AND DEVELOPMENT ASSOCIATION (Accredited by the National Aecreditation Board forTesting and Calibration Laboratories, Govt oflndia) ERDA Road, Makarpura Industrial Estate, Vadodara-390 010, India, EPABX : +91 (0265) 2642042, 2642964, 2642377, 3043128 / 29/30/31 /33 Fax: +91 (0266) 2638982 E-mail: erda@erda.org Web: hitoviwww.erda.org TEST REPORT NO.: RP-1617-027452 SHEET NO.: 3 OF 11 DATE 13/09/2016 Lightning Impulse Voltage Test Calibration Pulse fe ‘ TOR fv Tope TOO WS om |] ena: 2 | eedneeiocreb seed 4°" |} Up = 192.57 kv TL = 1.1068 us 12 = 49.486 us| bs) i Gree ee ; PREPARED BY CHECKED BY NS TE 1969446

You might also like