SURFACE SYSTEMS

Conventional Surface Wellheads


Flexibility, compatibility and interchangeability for a wide range of surface applications.
Conventional Wellhead Systems

S and IC Wellhead Systems . . . . . . . . . . . . . . . 3

Selecting a Wellhead System . . . . . . . . . . . 3


Cameron Conventional
Major Considerations for
Casing Hanger Selection . . . . . . . . . . . . . . . 3
Wellhead Systems
S Wellhead System. . . . . . . . . . . . . . . . . . . . 4

IC Wellhead System . . . . . . . . . . . . . . . . . . . 5

Casing Head Housings . . . . . . . . . . . . . . . . . . . 6 FLEXIBLE. COMPATIBLE. INTERCHANGEABLE.


Casing Head Housing
Bottom Connection Options . . . . . . . . . . . . 6
For a wide range of surface applications. Using
Casing Head Housing Comparison . . . . . . . 7

Casing Head Spools . . . . . . . . . . . . . . . . . . . . . 8 Cameron systems lets you reduce inventory require-
Secondary Seals. . . . . . . . . . . . . . . . . . . . . . . . . 8

Casing Head Spools Comparison . . . . . . . . 9 ments, lower costs and use standard components.
Secondary Seals Comparison. . . . . . . . . . . . 9

Casing Hangers . . . . . . . . . . . . . . . . . . . . . . . . 10 Cameron’s conventional wellheads and Christmas


Casing Hangers for S Casing Head
Housings and Spools . . . . . . . . . . . . . . . . . 10 trees suit any casing and tubing programs for working
SB Casing Hanger Comparison . . . . . . . . . 10

Casing Hangers for IC-2 Casing Head pressures up to 30,000 psi. For surface applications,
Housings and Spools . . . . . . . . . . . . . . . . . 11

IC Casing Hanger Comparison . . . . . . . . . . 11


Cameron equipment ranges from low pressure,
Tubing Spools and Hangers

Selecting a Completion System . . . . . . . . . . . 12


conventional equipment to systems for severe
Tubing Spool, Tubing Hanger Compatibility . 13

Major Considerations for service and geothermal applications.


Tubing Hanger Selection. . . . . . . . . . . . . . . . . 13

Tubing Spool Comparison. . . . . . . . . . . . . . . . 13


And Cameron’s reputation for quality ensures
Single Completions . . . . . . . . . . . . . . . . . . . . . 14

Tubing Spools for Single Completions . . . 14


that all wellhead products meet or exceed API 6A
Tubing Hangers for Single Completions. . 14

Comparison of Tubing Hangers specifications.


for Single Completions . . . . . . . . . . . . . . . 15

Dual and Critical Service Completions. . . . . . 16


For equipment requirements not covered in this
Tubing Spools for Dual Completions . . . . 16

Tubing Hangers for Dual Completions . . . 16


brochure, contact your Cameron representative.
Comparison of Tubing Hangers
for Dual Completions . . . . . . . . . . . . . . . . . 16

Tubing Spools–Critical Service Completions 17

Tubing Hangers–Critical Service Completions 17

Auxiliary Equipment

Lock Screws, Test Ports and Injection Ports . 18


SURFACE SYSTEMS

S AND IC WELLHEAD SYSTEMS CASING HANGER SELECTION CHART


Cameron’s two conventional wellhead systems—the 250°F
121°C
S system and the IC system—are both compatible with A
P
most Cameron tubing spool and hanger configurations. I

The S Conventional Wellhead System is the indus- T 180°F


82°C
E SB-5
M
try’s highest capacity conventional spool-type wellhead. P 150°F
65°C
E
Designed for use with all well depths and all types of R
SB-3
A
completions, the S system may be used in place of the T 100°F
38°C
U
R U T S P IC -1 SB-6
IC Wellhead for all applications. E
IC-1-P
50°F
For a wide range of applications, the IC Wellhead R 10°C IC-2
A
System offers a cost-effective, reliable alternative N
G
0°F
designed for less intense conditions. E -17°C
-20°F
-29°C
0 10% 20% 30% 40% 50% 60% 70% 80%

SELECTING A WELLHEAD SYSTEM Hang-Off Capacity (% of Pipe Body Yield)


(Operating conditions verified by
API 6A, 17th Edition, Appendix F testing)
The first step in determining which Cameron wellhead
system is best for your application is to determine the
capacity, working pressure and the method used to set
casing hanger style to be used. Each hanger profile is
the annulus seal. Please refer to the charts on this page
unique and is generally compatible with only a limited
as you select the casing hanger to suit your needs.
number of casing heads and spool bowls.
The four components to consider when selecting a
casing hanger are the temperature range, hang-off

MAJOR CONSIDERATIONS FOR CASING HANGER SELECTION


IC-1 IC-1-P IC-2 SB-3 SB-5 SB-6
-20°F to 150°F (-29°C to 65°C) • • •
Temperature Range* -20°F to 180°F (-29°C to 82°C) •
-20°F to 250°F (-29°C to 121°C) • •
Up to 50% of pipe body yield • • •
Hang-Off Capacity Up to 70% of pipe body yield •
Up to 80% of pipe body yield • •
5000 psi WP • •
Working Pressure 10,000 psi WP • •
10,000 and 15,000 psi WP • •
Method to Set Manual • • • • •
Annulus Seal Automatic • • • •
Seal Replaceable Yes • • • • •
with Load on Hanger No •
Spool/Housing Single 45° shoulder (IC-2 Series) • • •
Compatibility Double 45° shoulder (S Series)
* Note: Although final production may be at one temperature, operating temperature at the casing hanger may be lower.
• • •

3
Cameron Conventional Wellhead Systems
S CONVENTIONAL WELLHEAD SYSTEM
Designed for use with all well depths and all types of
completions, the Cameron S Conventional Wellhead
System offers the industry’s highest capacity conven- N Lock Screw

tional spool-type wellhead. The Cameron S Wellhead


T Tubing Hanger
incorporates the lower casing head housing, the casing
hanger and the subsequent casing head spools and
hangers. The S system is compatible with any of the
Tubing Spool
Cameron tubing spool and hanger configurations
shown on pages 12-17.

FEATURES Two 45˚ shoulders: the upper shoulder NX Bushing


supports the pack-off hydraulic pressure and test loads,
and the lower shoulder provides independent support
for the casing load. A large selection of secondary seals
SB-3
and pack-off bushings provides versatility. Casing Hanger

S CASING HANGER APPLICATION CHART S Casing Head


Spool
250°F
121°C
A
P
I

T 180°F
E 82°C SB-5
M
P 150°F
65°C
E
R
A
SB-3 Single P Seal
T 100°F
U 38°C
R U T S P SB-6
E S Casing Head
50°F Housing
R 10°C
A
N
G
0°F
E -17°C
SB-3
-20°F Casing Hanger
-29°C
0 10% 20% 30% 40% 50% 60% 70% 80%

Hang-Off Capacity (% of Pipe Body Yield)


(Operating conditions verified by
API 6A, 17th Edition, Appendix F testing)

Cameron S Wellhead System

4
SURFACE SYSTEMS

IC CONVENTIONAL WELLHEAD SYSTEM


For use in less extreme conditions, the Cameron IC
Conventional Wellhead System incorporates the lower
N Lock Screw casing head housing and hanger and the subsequent
casing head spools and hangers. Although components
T Tubing Hanger
are not interchangeable, the S Wellhead may be used in
place of the IC Wellhead for these applications as well.
Tubing Spool
The IC Wellhead, like the S Wellhead, is compatible
with any of the Cameron tubing spool and hanger con-
figurations shown on pages 12-17.

NX Bushing FEATURES Straight-bore design with 45˚ load shoulder.


A large selection of secondary seals and pack-off bush-
ings provides versatility.

IC-2 Casing
Hanger
IC CASING HANGER APPLICATION CHART

IC-2 Casing Head A


Spool P
I

T
E
M
P 150°F
65°C
E
R
A
T 100°F
U 38°C
R U T S P IC-1
Single P Seal
E
IC-1-P
50°F
R 10°C IC-2
A
N
G
IC-2 Casing Head 0°F
E
Housing -17°C
-20°F
-29°C
0 10% 20% 30% 40% 50% 60% 70% 80%
IC-2 Casing
Hanger Hang-Off Capacity (% of Pipe Body Yield)
(Operating conditions verified by API 6A,
17th Edition, Appendix F testing)

Cameron IC Wellhead System

5
SURFACE SYSTEMS

Cameron Conventional Wellhead Systems


H A N G E R S

TUBING HANGERS
Tubing hangers are available for single, dual and metal-sealing completions.
A N D
S P O O L S

T T-CL HT HT-2 CXS C-SRL-CL CD-2N CD-T CD-T-CL MTBS


(Single) (Single) (Single) (Single) (Single) (Single) (Dual) (Dual) (Dual) (Metal)

TUBING SPOOLS
Two tubing spool designs are available for standard
T U B I N G

service applications. The CD-2 Tubing Spool has the


same bowl configuration as the C Tubing Spool and
is compatible with dual tubing hangers. The MTBS
Spool is all-metal-sealing for critical applications.

C CD-2 MTBS
(Single Completions Only) (Single or Dual Completions) (Metal)

CASING
HANGERS
Three slip-type casing
H A N G E R S

hanger designs are


available for the S and
SB-3 SB-5* SB-6 IC-1* IC-1-P* IC-2
IC-2 Casing Spools.
Each hanger has specific
applications. In addition,
there are mandrel-type
casing hangers available
for both bowl types.
C A S I N G

CASING SPOOLS
The S and IC-2 Casing Spools have
several options for top connections. S/IC-2 S-11/IC-2-BP S-3/IC-2-L
One option features no lock screws;
another features two lock screws
180° apart; and the final option
A N D

features multiple lock screws Top flange lock screw configurations available for S and IC-2 Casing Spools.
depending on the flange size. *Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.
S P O O L S

S IC-2
C A S I N G

S E C O N D A RY S E A L S
A variety of secondary seals
are available to fit S and
IC-2 Casing Spools as well CANH™ Single P Double P Single T Double T NX Bushing
as the C, CD-2 and MTBS (For use with S spool only)
Tubing Spools.

CASING
H A N G E R S

HANGERS
Three slip-type casing
hangers are available for
the S and IC Casing Head SB-3 SB-5* SB-6 IC-1* IC-1-P* IC-2
Housings. Each hanger
has a specific application.
In addition, there are
mandrel-type casing hang-
C A S I N G

ers available for both bowl


types.

CASING HEAD HOUSING


The S and IC-2 Casing Head
Housings have several options S/IC-2 S-11/IC-2-BP S-3/IC-2-L
A N D

for top connections. One option


features no lock screws; another
features two lock screws 180°
apart; and the final option Top flange lock screw configurations available for S and IC-2 Casing Head Housings.
features multiple lock screws
H O U S I N G S

*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.
depending on the flange size.

S IC-2
Bottom Connections available for S and IC-2 Casing Head Housings

BOTTOM CONNECTIONS CR LANDING BASE


The S and IC-2 Casing Head The CR Landing Base can
H E A D

Housings are available with a be used with any style


selection of bottom connections housing to transfer loads
to match installation requirements. to the conductor.
C A S I N G

Slip-On Weld Slip-On Weld Slip Lock Casing Box CAMFORGE ™


CR Landing Base
with O-Ring without O-Ring Thread (Optional)
(Standard)
Casing Head Housings
The Casing Head Housing seals off the surface casing
and provides a landing bowl for the next casing string.
It also provides an attachment for the BOP stack.

CASING HEAD HOUSING


BOTTOM CONNECTION OPTIONS
SLIPLOCK™ CASING CONNECTION SYSTEM The SlipLock
Casing Connection System reduces installation time by
eliminating the need for welding. The system achieves
the necessary seal using elastomeric T Seals or plastic
S Casing Head Housing
injection-energized P Seals.
The SlipLock system performs in working pressures
up to 10,000 psi. Because it is reusable, it is an appropri-
ate choice for exploration wells.

CAMFORGE™ CASING CONNECTION SYSTEM The


CAMFORGE Casing Connection System requires no
welding and no pre-machining of the casing. Because
the casing is mechanically cut, existing production does
not have to be shut in. The connection is made using
hydraulic pressure to expand the surface casing and
IC-2 Casing Head Housing
housing. The system establishes a pressure-tight, metal-

S/IC-2 S-11/IC-2-BP S-3/IC-2-L

Top flange lock screw configurations available for S and IC-2 Casing Head Housings.
*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

S IC-2

Slip-On Weld Slip-On Weld Slip Lock Casing Box CAMFORGE™


with O-Ring without O-Ring Thread
(Standard)

6
SURFACE SYSTEMS

CASING HEAD HOUSING COMPARISON

Bowl Casing Lock Side Bottom Test Injection Landing


Wellhead Design Hangers Screws Outlets Connections Ports Ports Base

S Housing – no lock screws Casing box


threads
Line pipe
S-11 Housing – two lock screws threaded or Slip-on weld
Straight bore SB-3, SB-5 (with and Metal sealing, Include CR Landing
S Wellhead with dual 45° 180° apart for wear bushing retention studded with designed to buried check Base
shoulders and SB-6 threads for without O-ring) allow venting valves available
valve removal
S-3 Housing – full complement plugs SlipLock
of lock screws for casing hanger retention
(exact number dependent on flange size) CAMFORGE

IC-2 Housing – no lock screws Casing box


threads
Line pipe
IC-2-BP Housing – two lock screws threaded or Slip-on weld
Straight bore IC-1, IC-1-P (with and Metal sealing, Include CR Landing
IC Wellhead with single 45° 180° apart for wear bushing retention studded with designed to buried check Base
shoulder and IC-2 threads for without O-ring) allow venting valves available
valve removal
IC-2-L Housing – full complement plugs SlipLock
of lock screws for casing hanger retention
(exact number dependent on flange size) CAMFORGE

sealing connection suitable for working pressures up casing sizes, the O-ring seal option is not available. The
to 10,000 psi. The CAMFORGE system minimizes rig time O-ring seal requires only one external weld. Slip-on weld
and the duration of open hole time without BOP connections include a 1/2” line pipe test port to validate
protection. Annulus hydro-testing simulates working the integrity of both the weld and the O-ring seals.
conditions prior to BOP nipple-up.
CASING BOX THREAD When threaded connections are
SLIP-ON WELD Slip-on weld bottom connections are specified for casing heads, casing threads are used. In
standard with O-rings for both S and IC-2 casing heads this case, the standardized lower connection outside
with 10-3/4” or smaller casing preparations. For larger diameter allows use of raw material for either S or IC-2
style heads.

CR LANDING BASE The optional CR landing base can


be used with any style housing to transfer loads to the
conductor.

SlipLock Casing
Connection System

Casing Box Thread Slip-On Weld


with O-Ring

CAMFORGE Casing
Connection System

CR Landing Base
(Optional)
7
Casing Head Spools
The casing spool seals off the surface casing string,
and its landing bowl provides support for the next
casing string.

SECONDARY SEALS
Cameron offers a wide range of secondary seals for use
in casing and tubing spools. These secondary seals are
installed in the bottom of spools with corresponding
S Casing Head Spool
preps. Secondary seals include single P Seals, Double P
Seals, Single T Seals, Double T Seals, NX Bushings,
X Bushings and proprietary CANH™ Seals.

IC-2 Casing Head Spool

SB-3 SB-5* SB-6 IC-1* IC-1-P* IC-2

S/IC-2 S-11/IC-2-BP S-3/IC-2-L

Top flange lock screw configurations available for S and IC-2 Casing Spools.
*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

S IC-2

CANH™ Single P Double P Single T Double T NX Bushing


(For use with S spool only)

8
SURFACE SYSTEMS

CASING HEAD SPOOL COMPARISON

Bowl Casing Lock Side Secondary Test Injection


Wellhead Design Hangers Screws Outlets Seals Ports Ports

S Casing Head Spool – no lock screws


Single P,
Line pipe Double P,
S-11 Casing Head Spool – two lock screws threaded or
Straight bore SB-3, SB-5 Single T, Metal sealing, Include
180° apart for wear bushing retention studded with
S Wellhead with dual 45° Double T, designed to buried check
and SB-6 threads for
shoulders NX Bushing, allow venting valves
valve removal
S-3 Casing Head Spool – full complement X Bushing,
plugs
of lock screws for casing hanger retention CANH Seal
(exact number dependent on flange size)

IC-2 Casing Head Spool – no lock screws


Line pipe Single P,
IC-2-BP Casing Head Spool – two lock screws threaded or Double P,
Straight bore IC-1, IC-1-P Metal sealing, Include
IC Wellhead 180° apart for wear bushing retention studded with Single T,
with single 45° designed to buried check
and IC-2 threads for Double T,
shoulder allow venting valves
valve removal NX Bushing,
IC-2-L Casing Head Spool – full complement plugs X Bushing
of lock screws for casing hanger retention
(exact number dependent on flange size)

SECONDARY SEALS

Single P Seal Double P Seal Single T Seal

Double T Seal NX Bushing CANH™ Seal

SECONDARY SEALS COMPARISON

Casing Spool Tubing Spool Maximum Maximum Working Seal Means of


Model Compatibility Compatibility Service Rating Pressure (psi) Type Energizing Seal

Single P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

Double P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 15,000 Elastomeric Plastic Packing

SIngle T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Standard 5000 Elastomeric Radial Interference

Double T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 10,000 Elastomeric Radial Interference

X, NX Bushing S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

CANH Seal S, S-11, S-3 C, CD-2, MTBS Severe/Corrosive 20,000 Metal Flange Make-up

9
Casing Hangers
CASING HANGERS FOR S CASING HEAD tightening the cap screws. The seal can be replaced
HOUSINGS AND SPOOLS with the full-rated load on the hanger.
Cameron S Casing Head Housings and Spools accept all
three hangers in the SB hanger family. SB hangers can SB-5 CASING HANGER The SB-5 Casing Hanger is a
be lowered through the BOP as soon as the cement wrap-around slip and seal assembly designed for 10,000
plug hits bottom. Once in place, they support the entire and 15,000 psi WP
casing weight and seal the annulus. Mandrel style service. It is rated
casing hangers also can be supplied. for a hang-off
The unique slip design of the SB family of hangers capacity of 80 percent
achieves controlled friction when precision-machined of pipe body yield.
slips with sharp inner teeth securely bite the casing. Like the other slips in
Dull outer teeth on the back side contact the slip bowl. the SB family, it requires a load of only 15,000 pounds
Because these hangers are installed in the double 45˚ to set the seal. In addition, the seal can be re-energized
shoulder housing design, the mechanical load is by tightening the cap screws. The seal can be replaced
completely separated from the hydraulic load. This with the full-rated load on the hanger. The SB-5 Casing
separation permits the assembly to hold full test Hanger can be used only in the Type S spool; it cannot
pressure without changing deflection of casing in the be used with spools supplied with lock screws.
pressured zone, though the slip load can vary from
zero to full joint strength. SB-6 CASING HANGER The SB-6 Casing Hanger is a
wrap-around slip
SB-3 CASING HANGER The SB-3 Casing Hanger is a and seal assembly
wrap-around slip and seal assembly designed for 5000 designed for 5000
psi WP service. It psi WP service. It is
is rated for a rated for a hang-off
hang-off capacity capacity of 70 percent
of 80 percent of pipe of pipe body yield. Like the other slips in the SB family,
body yield. Like the it requires a load of only 15,000 pounds to set the seal.
other slips in the SB The seal can be re-energized by tightening the cap
family, it requires a load of only 15,000 pounds to set screws and can be replaced with the full-rated load on
the seal. In addition, the seal can be re-energized by the hanger.

SB CASING HANGER COMPARISON

Spool Hanger Operating Working Rated Load Method to Seal Replaceable


Model Compatibility Type Temperature Pressure (psi) Capacity Set Seal with Load on Hanger

Wrap-Around -20° to 250°F 80% minimum Casing Weight


SB-3 S, S-11, S-3 Slip and Seal 10,000/15,000 Yes
-29° to 121°C pipe body yield or Manual
Assembly
Wrap-Around -20° to 250°F 80% minimum Casing Weight
SB-5 S Slip and Seal 10,000/15,000 Yes
-29° to 121°C pipe body yield or Manual
Assembly
Wrap-Around -20° to 180°F 70% minimum Casing Weight
SB-6 S, S-11, S-3 Slip and Seal 5000 Yes
-29° to 82°C pipe body yield or Manual
Assembly

10
SURFACE SYSTEMS

CASING HANGERS FOR IC-2 CASING HEAD IC-1-P CASING HANGER The IC-1-P Casing Hanger is a
HOUSINGS AND SPOOLS one-piece, non-automatic, wrap-around hanger that is
Cameron IC-2 Casing Head Housings and Spools accept ideal for use when casing weight is insufficient to ener-
all three hangers in the IC hanger family. Cameron offers gize the hanger
a selection of IC hangers using manually energized seals seal. The seal is
or weight-set seals, depending upon application require- energized using
ments. IC hangers are available in one-piece and two- cap screws and can be
piece designs, so use of IC-2 equipment for different replaced with rated
applications can be varied by slip selection alone. load on the hanger.
IC hangers land on the single 45˚ shoulder in IC-2 bowls. This hanger can be used only in the IC-2 bowl profile; it
Mandrel style casing hangers also can be supplied. cannot be used with spools provided with lock screws.

IC-1 CASING HANGER The IC-1 Casing Hanger is an IC-2 CASING HANGER The IC-2 Casing Hanger is a
independent slip and seal assembly. The slip assembly is wrap-around hanger with an annulus seal. This hanger
latched around the casing and lowered into the casing is energized by casing weight, which varies with the
head. The seal casing and slip
assembly is size. The hanger
installed over the uses a heavy-duty
casing after it is cut latch and hinge design
off. Pressure applied that creates a reliable,
to the top of the seal strong and stable
assembly is transferred to the casing head, not to the hanger structure after closing. The hinge mechanism
slips. The IC-1 hanger can be used only in the IC-2 bowl enables the hanger halves to pivot out of the way
profile; it cannot be used with spools provided with during “wrap-around.” Tapered “rough backs” allow
lock screws. a quick, secure bite of the casing, restrict continued
downward movement, and prevent collapse of the
casing. A guide ring maintains slip alignment during
installation and operation.

IC CASING HANGER COMPARISON

Spool Hanger Operating Working Rated Load Method to Seal Replaceable


Model Compatibility Type Temperature Pressure (psi) Capacity Set Seal with Load on Hanger

Independent -20° to 150°F 50% minimum


IC-1 IC-2 Slip and Seal 5000 O-Rings Yes
-29° to 65°C pipe body yield
Assembly
Wrap-Around -20° to 150°F 50% minimum
IC-1-P IC-2 Slip and Seal 10,000 Cap Screws Yes
-29° to 65°C pipe body yield
Assembly
Wrap-Around -20° to 150°F 50% minimum
IC-2 IC-2, IC-2-BP, IC-2-L Slip and Seal 10,000 Casing Weight No
-29° to 65°C pipe body yield
Assembly

11
Tubing Spools and Hangers

TUBING SPOOLS AND HANGERS ment and Christmas trees to suit all tubing programs for
Cameron’s wide variety of tubing spools and hangers working pressures up to 30,000 psi. From low-pressure
suits all types of completions — single, dual, high conventional equipment to systems for severe service
pressure and severe service. and geothermal applications, Cameron can supply the
Cameron uses a standard C profile for tubing spools. completion components.
Use of this profile allows Cameron to offer the widest
possible array of tubing hanger choices while minimiz- SELECTING A COMPLETION SYSTEM The first step in
ing tubing spool requirements. Of the tubing hangers determining which Cameron completion system is best
offered, all but one — the MTBS (designed for critical for your application is to determine the tubing hanger
service applications) — fit the C profile. style to be used (see chart on page 13). Each hanger
Like our wellhead components, all Cameron comple- profile is unique and is generally compatible with only
tion components meet or exceed API 6A specifications. a limited number of casing head and spool bowls.
These products include a full line of completion equip-

T T-CL HT HT-2 CXS C-SRL-CL


(Single) (Single) (Single) (Single) (Single) (Single)

C
(Single Completions Only)

CD-2N CD-T CD-T-CL MTBS


(Dual) (Dual) (Dual) (Metal)

CD-2 MTBS
(Single or Dual Completions) (Metal)

12
SURFACE SYSTEMS

TUBING SPOOL, TUBING HANGER COMPATIBILITY

Tubing Hangers Tubing Spools


C CD-2 MTBS

HT Tubing Hanger Assembly • •


HT-2 Tubing Hanger Assembly • •
T Tubing Hanger • •
T-CL Tubing Hanger • •
C-SRL-CL Tubing Hanger • •
CXS Tubing Hanger • •
MTBS Tubing Hanger •

MAJOR CONSIDERATIONS FOR TUBING HANGER SELECTION


T T-CL HT HT-2 CXS CD-2N CD-T CD-T-CL MTBS

Completion Type
Single • • • • • •
Dual • • •
Coupling Assembly • •
Tubing Hanger Type Mandrel • • • •
Split Dual Mandrel • • •
5000 psi WP •
Working Pressure
10,000 psi WP • • •
15,000 psi WP • • • •
20,000 psi WP •
Annulus Seal Type Elastomer • • • • • • • •
Metal •
Neck Seal Type Elastomer • • • •
Metal • • •
No • • • •
Control Line Capability Standard, Continuous • • •
Optional, Non-Continuous • •
TUBING SPOOL COMPARISON

Tubing Completion Bowl Tubing Lock Side Secondary Test Injection


Spool Type Design Hangers Screws Outlets Seals Ports Ports

Straight Bore Line Pipe Threaded Single P, Double P,


HT, HT-2, C-SRL, or Studded with Metal Sealing,
C Single with Single 45˚ Type N Single T, Double T, Include Buried
T, T-CL, CXS Threads for Valve Designed to Allow
Shoulder NX Bushing, Check Valves
Removal Plugs Venting
CANH Seal

Straight Bore Line Pipe Threaded


CD-2N, CD-T or Studded with Single P, Double P, Metal Sealing,
CD-2 Single and Dual with Single 45˚ Type N Include Buried
CD-T-CL Threads for Valve Single T, Double T, Designed to Allow
Shoulder Check Valves
Removal Plugs NX Bushing Venting

Studded with Single P, Double P,


Straight Bore Metal Sealing,
Single, Threads for Valve Single T, Double T, Include Buried
MTBS with Single 45˚ MTBS Type N Designed to Allow
Metal Sealing Removal Plugs NX Bushing, Check Valves
Shoulder Venting
CANH Seal

13
Single Completions

TUBING SPOOLS FOR SINGLE COMPLETIONS around style casing hanger. The HT-2 is the preferred
Cameron’s C Tubing Spool is the standard spool for design for stainless steel applications. It incorporates a
single completions in 7-1/16” and 9” nominal top suspension nut that allows installation without rotating
flange sizes. The IC-2-L Spool is used for 11” and the Christmas tree. Both assemblies are rated up to
13-5/8” nominal tubing spools. Features include: 10,000 psi WP and are easy and quick to install without
special running tools.
BOWL DESIGN A straight bore with a single 45˚
shoulder design provides support for the tubing load HT AND HT-2 COUPLINGS Both designs include coarse
and reduces the risk of bowl damage from drill stem ACME threads, which make up easily with minimum
rotation. This design minimizes hoop load on the spool risk of damage. Self-energizing seals isolate threads
while maintaining high hanging capacity. from well fluids, allowing testing of the flange ring
gasket.
TUBING HANGER COMPATIBILITY The tubing spool
accommodates a wide variety of tubing hangers for single HT AND HT-2 ADAPTERS Both adapter top and bottom
completions including HT, HT-2, C-SRL-CL, T, T-CL and CXS connections are normally configured with a flanged
designs. See the following page for more information. bottom and studded top, providing a test port for veri-
fication of the adapter flange connection and coupling
TYPE N LOCK SCREWS Reliable Type N Lock Screws fea-
seal integrity.
ture packing installed in front of the threads to prevent
any contamination of threads by well-bore fluids and to HT-2 SUSPENSION NUT The HT-2 Suspension Nut is
help eliminate build-up of made of a high-strength, low-alloy, gall-resistant mate-
solids behind the screw. rial. A coupling seal isolates the nut from flow pressure,
See page 18 for more infor- preventing corrosion.
mation on Type N Lock C TUBING HANGER The C Tubing Hanger is a wrap-
Screws. around, slip and seal assembly. The annulus seal is ener-
SIDE OUTLETS Line-pipe gized by tubing weight or tie-down screws and controls
threaded and studded out- pressure in the casing annulus during installation of the
lets are available. Christmas tree.
Studded outlets are
threaded for valve The T, T-CL, C-SRL-CL and CXS Tubing Hangers are single

removal plugs. C Tubing Spool completion, mandrel-type hangers for use in either the
C Tubing Spool or the CD-2 Tubing Spool.
SECONDARY SEALS C Tubing Spools are available with
Single and Double P, Single and Double T, and NX T TUBING HANGER The T Tubing Hanger withstands

Bushing and CANH secondary seals. See pages 8-9 for the stress of high pressure and corrosive or erosive ele-

more information. ments associated with well flow. Its flexible neck main-
tains the metal seal despite thermal or pressure cycling.
TEST AND INJECTION PORTS All test ports are metal
sealing and are designed to allow venting. Injection T-CL TUBING HANGER The T-CL Tubing Hanger with-

ports include buried check valves. See page 18 for more stands stress of high pressure and corrosive or erosive

information. elements associated with well flow. A control line exit


block is available in either a bull plug style or block nee-

TUBING HANGERS FOR SINGLE COMPLETIONS dle valve style.

The HT and HT-2 Tubing Hanger Assemblies are single C-SRL-CL TUBING HANGER The C-SRL-CL Tubing Hanger
completion hanger assemblies for use in either the C incorporates a pressure energized SRL neck seal, which
Tubing Spool or the CD-2 Tubing Spool. Both designs are accommodates vertical movement in the tubing hanger
made up of a coupling, an adapter and a Type C wrap- during BOP testing. A control line exit block is available

14
SURFACE SYSTEMS

COMPARISON OF TUBING HANGERS FOR SINGLE COMPLETIONS

Spool Hanger Working Method to Annulus Neck Control BPV


Model Compatibility Type Pressure (psi) Set Seal Seal Seal Line Preparation

Coupling Assembly with Radial


HT C and CD-2 10,000 Elastomer Elastomer Not Available Standard
Type C Wrap-Around Hanger Interference

Rotatable Coupling Assembly Radial


HT-2 C and CD-2 10,000 Elastomer Elastomer Not Available Standard
with Type C Wrap-Around Hanger Interference

T C and CD-2 Mandrel 15,000 Lock Screws Elastomer Metal Not Available Standard
T-CL C and CD-2 Mandrel 15,000 Lock Screws Elastomer Metal Continuous Standard
C-SRL-CL C and CD-2 Mandrel 15,000 Lock Screws Elastomer Metal Continuous Standard
CXS C and CD-2 Mandrel 10,000 Lock Screws Elastomer Elastomer Optional Standard
MTBS MTBS Mandrel 20,000 Lock Screws Metal Metal Continuous Standard

in either a bull plug style or block needle valve style. CXS TUBING HANGER The CXS Tubing Hanger includes
The C-SRL-CL hanger should be used in 7-1/16” 10,000 psi two elastomeric neck seals that may be used to isolate
Type C Tubing Spools. one control line.

HT Tubing Hanger Assembly HT-2 Tubing Hanger Assembly T Tubing Hanger

T-CL Tubing Hanger CXS Tubing Hanger C-SRL-CL Tubing Hanger

15
Dual and Critical Service Completions
TUBING SPOOLS FOR DUAL COMPLETIONS SIDE OUTLETS Spools are available with line pipe
The CD-2 Tubing Spool features the same bowl as the threaded and studded outlets. Studded outlets are
C Tubing Spool but incorporates alignment pins for threaded for valve removal plugs.
dual completions. The CD-2 also can be used for single SECONDARY SEALS CD-2 Tubing Spools are available
completions by retracting with Single and Double P, Single and Double T and
the alignment pins. NX Bushing secondary seals. See pages 8-9 for more
Features include: information.
BOWL DESIGN A straight TEST AND INJECTION PORTS All test ports are metal
bore with a single 45˚ shoulder sealing and are designed to allow venting. Injection
design provides support for the ports include buried check valves. See page 18 for more
tubing load and reduces information.
the risk of bowl damage
due to drill stem rotation. CD-2 Tubing Spool
TUBING HANGERS FOR DUAL COMPLETIONS
This design minimizes hoop load on the spool while
Cameron’s dual completion tubing hangers include
maintaining high hanging capacity.
three designs: the CD-2N Tubing Hanger, CD-T Tubing
TUBING HANGER COMPATIBILITY The tubing spools Hanger and CD-T-CL Tubing Hanger. These hangers—
accommodate a wide variety of tubing hangers for sin- used with the CD-2 Tubing Spool—are split dual man-
gle completions including HT, HT-2, C-SRL-CL, T, T-CL drel style hangers that can be run and pulled independ-
and CXS designs for single completions and the CD-2N, ently. The alignment slots are located below the load
CD-T and CD-T-CL hangers for dual completions. shoulder to protect the alignment pins from tubing
TYPE N LOCK SCREWS Reliable Type N Lock Screws fea- weight, allowing maximum load capacity.
ture packing installed in front of the threads to prevent
contamination of the threads by wellbore fluids and to
help eliminate build-up of solids behind the screw. See
page 18 for more information.

ALIGNMENT PINS Alignment pins for dual completions


are located below the load shoulder to avoid test plug
interference and to provide alignment without reduc-
ing load shoulder capacity. CD-2N CD-T CD-T-CL
Tubing Hanger Tubing Hanger Tubing Hanger

COMPARISON OF TUBING HANGERS FOR DUAL COMPLETIONS

Spool Hanger Working Method to Annulus Neck Control BPV


Model Compatibility Type Pressure (psi) Set Seal Seal Seal Line Preparation

Split Dual Mandrel Optional,


CD-2 CD-2 10,000 Lock Screws Elastomer Elastomer Standard
(Two Piece) Continuous

Split Dual Mandrel


CD-T CD-2 15,000 Lock Screws Elastomer Metal Not Available Standard
(One Piece)

CD-T-CL CD-2 Split Dual Mandrel 15,000 Lock Screws Standard,


(One Piece) Elastomer Metal Standard
Continuous

16
SURFACE SYSTEMS

TUBING SPOOLS FOR SIDE OUTLETS MTBS Spools are available with studded
CRITICAL SERVICE COMPLETIONS outlets threaded for valve removal plugs.
The MTBS Tubing Spool is a single completion, metal-to-
SECONDARY SEALS MTBS Tubing Spools are available
metal sealing spool for critical service applications to
with Single and Double P, Single and Double T and NX
20,000 psi WP. Features
Bushing and CANH secondary seals. See pages 8-9 for
include:
more information.
METAL-TO-METAL SEALING
TEST AND INJECTION PORTS All test ports are metal
The MTBS Tubing Spool
sealing and are designed to allow venting. Injection
and MTBS Tubing Hanger
ports include buried check valves. See page 18 for more
provide complete metal-to-
information.
metal sealing. The annulus
seal is squeezed to contact
TUBING HANGERS FOR
parallel cylindrical sealing CRITICAL SERVICE COMPLETIONS
MTBS Tubing Spool
surfaces in the spool bore. The MTBS Tubing Hanger is made of
The annulus seal is set using tubing weight with addi- high alloy materials to withstand
tional pressure load when required. The neck seal is corrosive and high temperature
energized by flange make up. environments. The extended
MTBS TUBING HANGER The MTBS Tubing Hanger is neck ensures positive
made of high alloy materials to withstand corrosive alignment for the seal
and high temperature environments. The extended during installation. The
neck ensures positive alignment for the seal during hanger is reusable, and the
installation. The hanger is reusable, and the metal metal seals are replaceable.
seals are replaceable.

BOWL DESIGN A straight bore bowl design provides a


large through bore and allows a 7-1/16” flange to be
MTBS Tubing Hanger
used over all 7”casing strings.

TYPE N LOCK SCREWS Reliable N Lock Screws feature


packing installed in front of the threads. This prevents
contamination of threads by wellbore fluids and helps
eliminate build-up of solids behind the screw. See page
18 for more information on N Lock Screws.

17
Auxiliary Equipment
LOCK SCREWS, TEST PORTS AND INJECTION PORTS

N LOCK SCREWS All Cameron spools and housings use


N Lock Screws. These field-replaceable screws contain
packing in front of the threads to prevent contamina-
tion by well bore fluids and build up of solids behind
the screws, which could prevent proper retraction.
An external oil seal protects threads from atmospheric
corrosion. N Lock Screw

TEST PORTS All test ports used in Cameron convention-


al wellhead equipment meet the standard for API 6A
Type II metal seal design for safety and reliability.
These ports can be vented safely and are usable with
all pressure ratings.

INJECTION PORTS For casing and tubing spools that


require injection of sealant to energize or re-energize
the secondary seal, two styles of fittings are available. Test Port

Each style has a buried ball check (without spring). For


applications 10,000 psi WP and below, the port features
a simple plug with a 1” NPT thread. For working pres-
sures above 10,000 psi WP, the port incorporates a two-
piece plug with a pressure vent.

Injection Port
(10,000 psi WP and Below)

Injection Port
(15,000 psi WP and Above)

18
SURFACE SYSTEMS
SURFACE SYSTEMS
PO Box 1212
Houston, Texas 77251-1212
USA
Tel 1-713-939-2211
Fax 1-713-939-2620

5 Mondial Way
Harlington
Hayes, UB3 5AR
England
Tel 44-208-990-1800
Fax 44-208-990-1888

No. 2 Gul Circle, Jurong Industrial Est


Singapore 629560
Singapore
Tel 65-6861-3355
Fax 65-6415-1198

DRILLING & PRODUCTION SYSTEMS


PO Box 1212
Houston, Texas 77251-1212
USA
Tel 1-713-939-2211
Fax 1-713-939-2620

Learn more about


Conventional Wellhead Systems at:
www.c-a-m.com

HSE Policy Statement


At Cameron, we are committed ethically, financially and personally to a working environment
where no one gets hurt, nothing gets harmed.

© 2006 Cameron International Corporation | Cameron, CAMFORGE, CANH and SlipLock are trademarks of Cameron International Corporation | TC1261 Rev 1 SWP 4/08 2M