Professional Documents
Culture Documents
Carport Addition ETABS Report PDF
Carport Addition ETABS Report PDF
5/15/2014
Table of Contents
1. Structure Data 4
2. Properties 5
2.1 Materials 5
2.2 Frame Sections 5
2.3 Shell Sections 5
3. Loads 6
4. Design Data 21
Page 2 of 25
List of Tables
Page 3 of 25
Structure Data 5/15/2014
1 Structure Data
This chapter provides model geometry information, including items such as story levels, point coordinates, and
element connectivity.
X Y Bubble
Story Rotation
Name Type Origin Origin Size Color
Range deg
ft ft in
G1 Cartesian Default 0 0 0 60 ffa0a0a0
ΔZ
X Y
Label Below
in in
in
2587 0 320.04 0
2588 240 320.04 0
2589 240 0 0
2590 0 0 0
2591 -12 320.004 0
2592 276 0 0
2593 276 320.04 0
2594 -12 -36 0
2595 276 -36 0
2596 -12 0 0
Page 4 of 25
Properties 5/15/2014
2 Properties
This chapter provides property information for materials, frame sections, shell sections, and links.
2.1 Materials
Table 2.1 - Material Properties - Summary
Unit
E
Name Type ν Weight Design Strengths
lb/in²
lb/ft³
A615Gr60 Rebar 29000000 0.3 490 Fy=60000 lb/in², Fu=90000 lb/in²
CONC Concrete 3600000 0.2 150 Fc=3000 lb/in²
Total
Design Element
Name Material Thickness
Type Type
in
SLAB6 Slab Membrane CONC 6.5
Page 5 of 25
Loads 5/15/2014
3 Loads
This chapter provides loading information as applied to the model.
3.1 Load Patterns
Table 3.1 - Load Patterns
Self
Name Type Weight Auto Load
Multiplier
DEAD Dead 1
LIVE Live 0
EQXPOS Seismic 0 ASCE 7-05
EQXNEG Seismic 0 ASCE 7-05
EQYPOS Seismic 0 ASCE 7-05
EQYNEG Seismic 0 ASCE 7-05
W Wind 0 ASCE 7-05
W-2 Wind 0 ASCE 7-05
W-3 Wind 0 ASCE 7-05
W-4 Wind 0 ASCE 7-05
W-5 Wind 0 ASCE 7-05
W-6 Wind 0 ASCE 7-05
W-7 Wind 0 ASCE 7-05
W-8 Wind 0 ASCE 7-05
W-9 Wind 0 ASCE 7-05
W-10 Wind 0 ASCE 7-05
W-11 Wind 0 ASCE 7-05
W-12 Wind 0 ASCE 7-05
Page 6 of 25
Loads 5/15/2014
Direction = X + Eccentricity Y
Eccentricity Ratio = 5% for all diaphragms
Structural Period
Page 7 of 25
Loads 5/15/2014
S DS
Seismic Response Coefficient, C S [ASCE
CS = R
12.8.1.1, Eq. 12.8-2] ( )
I
SD1
[ASCE 12.8.1.1, Eq. 12.8-3] CS,max = R
T( )
I
Page 8 of 25
Loads 5/15/2014
20.341kip
ROOF
BASE
0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0
Force, kip
Page 9 of 25
Loads 5/15/2014
Direction = X - Eccentricity Y
Eccentricity Ratio = 5% for all diaphragms
Structural Period
Page 10 of 25
Loads 5/15/2014
S DS
Seismic Response Coefficient, C S [ASCE
CS = R
12.8.1.1, Eq. 12.8-2] ( )
I
SD1
[ASCE 12.8.1.1, Eq. 12.8-3] CS,max = R
T( )
I
Page 11 of 25
Loads 5/15/2014
20.341kip
ROOF
BASE
0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0
Force, kip
Page 12 of 25
Loads 5/15/2014
Direction = Y + Eccentricity X
Eccentricity Ratio = 5% for all diaphragms
Structural Period
Page 13 of 25
Loads 5/15/2014
S DS
Seismic Response Coefficient, C S [ASCE
CS = R
12.8.1.1, Eq. 12.8-2] ( )
I
SD1
[ASCE 12.8.1.1, Eq. 12.8-3] CS,max = R
T( )
I
Page 14 of 25
Loads 5/15/2014
ROOF
20.341kip
BASE
0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0
Force, kip
Page 15 of 25
Loads 5/15/2014
Direction = Y - Eccentricity X
Eccentricity Ratio = 5% for all diaphragms
Structural Period
Page 16 of 25
Loads 5/15/2014
S DS
Seismic Response Coefficient, C S [ASCE
CS = R
12.8.1.1, Eq. 12.8-2] ( )
I
SD1
[ASCE 12.8.1.1, Eq. 12.8-3] CS,max = R
T( )
I
Page 17 of 25
Loads 5/15/2014
ROOF
20.341kip
BASE
0.0 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0
Force, kip
Page 18 of 25
Loads 5/15/2014
3.3 Functions
3.3.1 Response Spectrum Functions
Period TL Site
Name Acceleration Damping Latitude Longitude Ss S1 Fa Fv
sec sec Class
IBC2009 0 0.744 5 0 0 2.79 0.68 12 D 1 1.5
IBC2009 0.073 1.86
IBC2009 0.366 1.86
IBC2009 0.6 1.133333
IBC2009 0.8 0.85
IBC2009 1 0.68
IBC2009 1.2 0.566667
IBC2009 1.4 0.485714
IBC2009 1.6 0.425
IBC2009 1.8 0.377778
IBC2009 2 0.34
IBC2009 2.5 0.272
IBC2009 3 0.226667
IBC2009 3.5 0.194286
IBC2009 4 0.17
IBC2009 4.5 0.151111
IBC2009 5 0.136
IBC2009 5.5 0.123636
IBC2009 6 0.113333
IBC2009 6.5 0.104615
IBC2009 7 0.097143
IBC2009 7.5 0.090667
IBC2009 8 0.085
IBC2009 8.5 0.08
IBC2009 9 0.075556
IBC2009 9.5 0.071579
IBC2009 10 0.068
Page 19 of 25
Loads 5/15/2014
Name Type
DEAD Linear Static
LIVE Linear Static
EQXPOS Linear Static
EQXNEG Linear Static
EQYPOS Linear Static
EQYNEG Linear Static
W Linear Static
W-2 Linear Static
W-3 Linear Static
W-4 Linear Static
W-5 Linear Static
W-6 Linear Static
W-7 Linear Static
W-8 Linear Static
W-9 Linear Static
W-10 Linear Static
W-11 Linear Static
W-12 Linear Static
RSX Response Spectrum
RSY Response Spectrum
Page 20 of 25
Design Data 5/15/2014
4 Design Data
This chapter provides design data and results.
4.1 Concrete Frame Design
Table 4.1 - Concrete Frame Preferences - ACI 318-08
Item Value
Multi-Response Design Step-by-Step
Seismic Design Category D
# Interaction Curves 24
# Interaction Points 11
Minimum Eccentricity Yes
Phi (Tension) 0.9
Phi (Compression Tied) 0.65
Phi (Compresseion Spiral) 0.7
Phi (Shear and Torsion) 0.85
Phi (Shear Seismic) 0.6
Phi (Shear Joint) 0.85
Pattern Live Load Factor 0.75
D/C Ratio Limit 1
Unique Design
Story Label Design Section LLRF LMajor LMinor KMajor KMinor CmMajor
Name Type
ROOF C56 12 Column Program Determined 1 0.824561 0.824561 1 1 1
ROOF C57 13 Column Program Determined 0.978495 0.824561 0.824561 1 1 1
ROOF C58 14 Column Program Determined 0.952699 0.824561 0.824561 1 1 1
ROOF C59 15 Column Program Determined 0.97491 0.824561 0.824561 1 1 1
Unique
Story Label CmMinor DnsMajor DnsMinor DsMajor DsMinor
Name
ROOF C56 12 1 1 1 1 1
ROOF C57 13 1 1 1 1 1
ROOF C58 14 1 1 1 1 1
ROOF C59 15 1 1 1 1 1
Unique Design
Story Label Design Section LLRF LMajor LMinor
Name Type
ROOF B355 16 Beam Program Determined 0.965305 0.956254 0.956254
ROOF B356 17 Beam Program Determined 0.922632 0.956254 0.956254
ROOF B357 18 Beam Program Determined 1 0.941665 0.941665
ROOF B358 19 Beam Program Determined 1 0.941665 0.941665
Page 21 of 25
Design Data 5/15/2014
ROOF C56 12 0 0.245 0.245 ULTSPE8 0.4247 ULTE08 0.6321 No Message No Message
ROOF C56 12 47 0.245 0.245 ULTSPE8 0.4247 ULTE08 0.6307 No Message No Message
ROOF C56 12 94 0.6281 0.6281 ULTSPE8 0.4247 ULTSPE4 0.634 -33 No Message
ROOF C57 13 0 0.245 0.245 ULTSPE8 0.4268 ULTE09 0.6685 No Message No Message
ROOF C57 13 47 0.245 0.245 ULTSPE8 0.4268 ULTE09 0.6674 No Message No Message
ROOF C57 13 94 0.6982 0.6982 ULTSPE8 0.4268 ULTE04 0.6684 -33 No Message
ROOF C58 14 0 0.245 0.245 ULTSPE8 0.4903 ULTSPE8 0.6756 No Message No Message
ROOF C58 14 47 0.245 0.245 ULTSPE8 0.4903 ULTSPE8 0.6746 No Message No Message
ROOF C58 14 94 0.7189 0.7189 ULTSPE8 0.4903 ULTE16 0.679 -33 No Message
ROOF C59 15 0 0.245 0.245 ULTSPE8 0.4675 ULTSPE8 0.6353 No Message No Message
ROOF C59 15 47 0.245 0.245 ULTSPE8 0.4675 ULTSPE8 0.6353 No Message No Message
ROOF C59 15 94 0.6577 0.6577 ULTSPE8 0.4675 ULTSPE8 0.6353 No Message No Message
As,min As As,min As
Unique Station Design As Top As Top
Story Label Status Top Bottom Bottom Bottom
Name in Section Combo in²
in² Combo in² in²
ROOF B355 16 7.0002 RB-1 No Message ULTE08 0.7075 1.2932 ULTE08 0.7275 0.7275
ROOF B355 16 30.5417 RB-1 No Message ULTE16 0.7075 0.7075 ULTE15 0.5238 0.5238
ROOF B355 16 54.0832 RB-1 No Message ULTE08 0.4071 0.4071 ULTE15 0.7275 0.7275
ROOF B355 16 77.6247 RB-1 No Message ULTE08 0.4071 0.4071 ULTE07 0.7275 0.8952
ROOF B355 16 101.1662 RB-1 No Message ULTE08 0.4071 0.4071 ULTE07 0.7275 1.0851
ROOF B355 16 124.7077 RB-1 No Message ULTE08 0.4071 0.4071 ULTE07 0.7275 1.1877
ROOF B355 16 148.2492 RB-1 No Message ULTE08 0.4071 0.4071 ULTV2 0.7275 1.2531
ROOF B355 16 171.7908 RB-1 No Message ULTE08 0.4071 0.4071 ULTV2 0.7275 1.2533
ROOF B355 16 195.3323 RB-1 No Message ULTE08 0.4071 0.4071 ULTE08 0.7275 1.1885
ROOF B355 16 218.8738 RB-1 No Message ULTE08 0.4071 0.4071 ULTE08 0.7275 1.0863
ROOF B355 16 242.4153 RB-1 No Message ULTE08 0.4071 0.4071 ULTE08 0.7275 0.8968
Page 22 of 25
Design Data 5/15/2014
As,min As As,min As
Unique Station Design As Top As Top
Story Label Status Top Bottom Bottom Bottom
Name in Section Combo in²
in² Combo in² in²
ROOF B355 16 265.9568 RB-1 No Message ULTE08 0.4071 0.4071 ULTE16 0.7275 0.7275
ROOF B355 16 289.4983 RB-1 No Message ULTE15 0.7075 0.7075 ULTE16 0.5258 0.5258
ROOF B355 16 313.0398 RB-1 No Message ULTE07 0.7075 1.2902 ULTE07 0.7275 0.7275
ROOF B356 17 7.0002 RB-1 No Message ULTE06 0.7075 1.4711 ULTE14 0.7275 0.7275
ROOF B356 17 30.5417 RB-1 No Message ULTE06 0.7075 0.7709 ULTE13 0.5228 0.5228
ROOF B356 17 54.0832 RB-1 No Message ULTE05 0.4601 0.4601 ULTE15 0.7275 0.7275
ROOF B356 17 77.6247 RB-1 No Message ULTE05 0.4601 0.4601 ULTE05 0.7275 1.0155
ROOF B356 17 101.1662 RB-1 No Message ULTE05 0.4601 0.4601 ULTE05 0.7275 1.253
ROOF B356 17 124.7077 RB-1 No Message ULTE05 0.4601 0.4601 ULTE05 0.7275 1.3864
ROOF B356 17 148.2492 RB-1 No Message ULTE05 0.4601 0.4601 ULTV2 0.7275 1.4926
ROOF B356 17 171.7908 RB-1 No Message ULTE05 0.4601 0.4601 ULTV2 0.7275 1.4924
ROOF B356 17 195.3323 RB-1 No Message ULTE05 0.4601 0.4601 ULTE06 0.7275 1.3859
ROOF B356 17 218.8738 RB-1 No Message ULTE05 0.4601 0.4601 ULTE06 0.7275 1.252
ROOF B356 17 242.4153 RB-1 No Message ULTE05 0.4601 0.4601 ULTE06 0.7275 1.0141
ROOF B356 17 265.9568 RB-1 No Message ULTE05 0.4601 0.4601 ULTE16 0.7275 0.7275
ROOF B356 17 289.4983 RB-1 No Message ULTE05 0.7075 0.7734 ULTE14 0.5211 0.5211
ROOF B356 17 313.0398 RB-1 No Message ULTE05 0.7075 1.4744 ULTE13 0.7275 0.7275
ROOF B357 18 7.0002 RB-2 No Message ULTE04 0.7075 0.9259 ULTE11 0.6664 0.6664
ROOF B357 18 29.6002 RB-2 No Message ULTE12 0.675 0.675 ULTE11 0.7275 0.7275
ROOF B357 18 52.2001 RB-2 No Message ULTE03 0.3113 0.3113 ULTE11 0.7275 0.7275
ROOF B357 18 74.8001 RB-2 No Message ULTE03 0.3113 0.3113 ULTE11 0.7275 0.7275
ROOF B357 18 97.4 RB-2 No Message ULTE03 0.3113 0.3113 ULTSPE4 0.7275 0.7275
ROOF B357 18 120 RB-2 No Message ULTE03 0.3113 0.3113 ULTSPE4 0.7275 0.7275
ROOF B357 18 142.6 RB-2 No Message ULTE03 0.3113 0.3113 ULTSPE4 0.7275 0.7275
ROOF B357 18 165.1999 RB-2 No Message ULTE03 0.3113 0.3113 ULTE12 0.7275 0.7275
ROOF B357 18 187.7999 RB-2 No Message ULTE03 0.3113 0.3113 ULTE12 0.7275 0.7275
ROOF B357 18 210.3998 RB-2 No Message ULTE11 0.7068 0.7068 ULTE04 0.7077 0.7077
ROOF B357 18 232.9998 RB-2 No Message ULTE03 0.7075 0.9745 ULTE12 0.6276 0.6276
ROOF B358 19 7.0002 RB-2 No Message ULTE02 0.7075 0.8354 ULTE09 0.6045 0.6045
ROOF B358 19 29.6002 RB-2 No Message ULTE10 0.6245 0.6245 ULTE01 0.6651 0.6651
ROOF B358 19 52.2001 RB-2 No Message ULTE10 0.2742 0.2742 ULTE01 0.7275 0.7275
ROOF B358 19 74.8001 RB-2 No Message ULTE01 0.2699 0.2699 ULTE03 0.7275 0.7275
ROOF B358 19 97.4 RB-2 No Message ULTE01 0.2699 0.2699 ULTE03 0.7275 0.7275
ROOF B358 19 120 RB-2 No Message ULTE01 0.2699 0.2699 ULTV2 0.7275 0.7275
ROOF B358 19 142.6 RB-2 No Message ULTE01 0.2699 0.2699 ULTE04 0.7275 0.7275
ROOF B358 19 165.1999 RB-2 No Message ULTE01 0.2699 0.2699 ULTE04 0.7275 0.7275
ROOF B358 19 187.7999 RB-2 No Message ULTE09 0.2762 0.2762 ULTE02 0.7275 0.7275
ROOF B358 19 210.3998 RB-2 No Message ULTE09 0.6274 0.6274 ULTE02 0.6605 0.6605
ROOF B358 19 232.9998 RB-2 No Message ULTE01 0.7075 0.8397 ULTE10 0.6008 0.6008
Page 23 of 25
Design Data 5/15/2014
Page 24 of 25
Design Data 5/15/2014
At Torsion Al Torsion At
Unique Station
Story Label V Combo Shear Long Torsion Tran Torsion Warnings Errors
Name in
in²/ft Combo in² Combo in²/ft
ROOF B358 19 120 ULTSPE8 0.12 ULTSPE8 0 ULTSPE8 0 No Message No Message
ROOF B358 19 142.6 ULTSPE8 0.1497 ULTSPE8 0 ULTSPE8 0 No Message No Message
ROOF B358 19 165.1999 ULTSPE8 0.1748 ULTSPE8 0 ULTSPE8 0 No Message No Message
ROOF B358 19 187.7999 ULTE11 0.2005 ULTSPE8 0 ULTSPE8 0 No Message No Message
ROOF B358 19 210.3998 ULTE14 0.2162 ULTSPE8 0 ULTSPE8 0 No Message No Message
ROOF B358 19 232.9998 ULTSPE8 0.2267 ULTSPE8 0 ULTSPE8 0 No Message No Message
JS JS JS JS
Unique
Story Label Major Major Minor Minor Warnings Errors
Name
Combo Ratio Combo Ratio
ROOF C56 12 ULTE01 0.343 ULTE01 0.53 Beam/Column capacity ratio exceeds limit No Message
ROOF C57 13 ULTE01 0.345 ULTE01 0.606 Beam/Column capacity ratio exceeds limit No Message
ROOF C58 14 ULTE01 0.4 ULTE01 0.605 Beam/Column capacity ratio exceeds limit No Message
ROOF C59 15 ULTE01 0.38 ULTE01 0.531 No Message No Message
Page 25 of 25