Calculation Colomn
Calculation Colomn
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.1
Date:
Drwg Calc by:
Checked by:
References Calculation Output
1. fcu = 30 N/mm2
2. fy = 500 N/mm2
3. fyv = 250 N/mm2
4. θbar = mm
5. c = 30mm
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.2
Date:
Calc by:
Checked by:
References Calculation Output
Classify Column
Loading
Hence the load of ground beam is the same of the load from first
floor beam
= 80.5kN
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.3
Drwg Date:10/11/11
Calc by: Nik
Ref:HS/RC-
Zafirah Checked by:
01/04
References Calculation Output
Moment
24.8 kN/m
2.5m 3.5m
Top :
= 5.93 kNm
Bottom :
M (x-x) = 5.93 / 2 = 2.97kNm
5.93
2.97
Cross-section y-y
My-y =0
0
0
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.5
Drwg Date:10/11/11
Calc by: Nik
Ref:HS/RC-
Zafirah Checked by:
01/04
References Calculation Output
Top :
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.6
Drwg Date:10/11/11
Calc by: Nik
Ref:HS/RC-
Zafirah Checked by:
01/04
References Calculation Output
h’ = h – c – θ bar / 2 - θ link
= 175mm – 30mm – 12/2 – 8 = 131mm
b’ = b – c – θ bar / 2 - θ link
= 125mm – 30mm – 12/2 – 8 = 81mm
equation 36
Moment Critical
Mcx
Mi = 0.4M1 + 0.6M2 = 0.4(11.0) + 0.6(22.0)
= 17.6kNm
Equation 36 Mcy
Mi = 0.4M1 + 0.6M2 = 0.4(4.8) + 0.6(9.6)
= 7.68kN
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.7
Drwg Date:10/11/11
Calc by: Nik
Ref:HS/RC-
Zafirah Checked by:
01/04
References Calculation Output
Job ref:BS8110:Part1:1985
Part of structure : Column
Calculation sheet No.8
Drwg Date:10/11/11
Calc by: Nik
Ref:HS/RC-
Zafirah Checked by:
01/04
References Calculation Output
Shear Reinforcement :
Diameter link > d/4 = 12/4
= 3mm < 6mm Use 6mm
Spacing between link = 12d
= 12 x 12 = 144mm
Link Use
Use R6 – 125mm R6 – 125mm
Detailing
Ref. Calculations Remarks Ref.
SPECIFICATION
Classification : Braced non-slender column
Material : Axial force , Ned =81 kN
Concrete, fck = 25 N/mm2 M
Reinforcement, fyk =500 N/mm 2
y 250
Exposure class = XC1
Fire resistance = 1.0 hours
Design life = 50 years z 250
Size, b x h =250 x 250 mm 5.93 kNm Design
Effective length, l o = 2.2 Chart
Assumed : φ link = 8 mm
φ bar = 16 mm
Use : H6 - 175