You are on page 1of 2

1700

2900 2900 SHOP DRAWING REVIEW


135 1550 ARCHITECT:
750 900 1250 9.53Ø LIFTING STRAND 550 700 900 750
4 NOS. (FOR LIFTING 15
15
MKPL ARCHITECTS PTE LTD
250 250
SFL DEMOULDING) 135
150 CECIL STREET
#12-00 SINGAPORE 069543
TEL 65 6223 4633 FAX 65 6223 4233
175

175

175
Review for Conformance with project design concept. This review does not in any way relieve contractor
35

35

35
from responsibility for correctness of dimension, quantities, calculation, construction, fabrication
SOFFIT LVL

55
techniques and co-ordination of work of other trades Non-conformities and errors detected are noted.
REVIEW COMPLETED

275
305

305
325

325
RECEIVED FOR INFO ONLY
RESUBMIT

5
5
MAKE CORRECTIONS NOTED

12
12
850 850 1700 1200 REJECTED

255
SIGN : _______________ DATE: _______________

50
20mm Ø PVC CONCEALED PIPE STRUCTURAL AND CIVIL ENGINEER:
KTP CONSULTANTS PTE LTD
3791 JALAN BUKIT MERAH
#05-18 E-CENTRE @ REDHILL 159471
TEL 65 6273 5622 FAX 65 6273 8454

DE
DE This check is made to review the general confromance on the design intention only, as this

DETA
TA
TA is a Design & Build Development. This does not relieve the contractor and Sub-Contractor

DET
IL
of his contractual obligation and responsibilities to ensure the adequacy, integrity, suitability
ILS

SS
and practicality of the proposed detail design and that it is fit for its intended purpose and in
SE

ILS SE
A
accordance with the Employer's Requirements; and to confirm and correlate dimensions on

EE

ILS
EP
2800

2800

2800
site, select fabrications process and techniques of construction, coordinate his work with all

PLA
LA other trades and execute his works in accordance with the best standard practice and

SEE
2610

2610

2630
N Local Building Regulations as well as the approved plans.

E
N

100
APPROVED REVISE & RESUBMIT COMMENTS ON STRUCT'L.

PLAN
PLA
ASPECTS ONLY

2355
2305
2285

2285
APPROVED REJECTED NO COMMENT

N
75 50 50

1900
WITH COMMENTS
NAME & SIGNATURE : _______________ DATE: _______________

MECHANICAL & ELECTRICAL ENGINEER:


ALPHA CONSULTING ENGINEERS PTE LTD
2 BUKIT MERAH CENTRAL

1200
360 50 50 #16-00 SPRNG SINGAPORE 159835
TEL 65 6276 2228 FAX 65 6276 9929
Review of this shop drawing / submitted is only to check for

100
general conformance with the specifications and drawings.
20mm Ø PVC CONCEALED PIPE Comments / corrections made do not relieve the Contractor/
Sub-Contractor of his contractual responsibility and from

450
compliance with requirements of the Contract Documents.
HHS INT. F.F.L. D-4 The Contractor / Sub-Contractor remains responsible for
150

150

150

150

150
5050
the correctness of quantities and dimensions, selection of
materials / equipment, fabrication processess, methods
15

15
SFL D-4 of installation, coordination of work with all other trades
and the safe and satisfactory performance of the work.
NO EXCEPTION TAKEN REVISE - NO RESUBMISSION REQ'D.
300 2300 300 300 400 300 400 300 300 950 5050 700 50 200 300 300
REVISE AND RESUBMIT SUBMIT SPECIFIED ITEM REJECTED
LEGEND: 2900 2900 REVIEWED BY : _______________ SIGN : ____________

20MM HIGH PROTRUSION DATE RECEIVED :________ DATE RETURNED : __________


FROM SOFFIT LVL.
Left Side View Rear View Right Side View
5MM RECESS FROM SOFFIT LVL.

100MM DROP FROM SOFFIT LVL.

1700
55MM DROP FROM SOFFIT LVL.
300 400 300 400 300 50 150 50 3 10/1/19 HST REV. BASED ON KTP
1700 COMMENT
BOX OUT(BEAM CUT) 250 1450 2 20/12/18 HST GENERAL REVISION
15
DETAIL 3 9.53Ø LIFTING STRAND
1550
DETAIL 1 10 10 1 20/11/18 HST REV. BASED ON ALPHA
COMMENT
REAR VIEW 135
4 NOS. (FOR LIFTING 15 135 REV DATE NAME SUBJECT
DEMOULDING) 200 SFL SPLICE SLEEVE DEVELOPER:

50
250

250

HOUSING & DEVELOPMENT BOARD


300

300

10
175

35
50

35

512 BISHAN STREET 13


5520

100
SOFFIT LVL #02-524 SINGAPORE 570512

150
275

275
300

10
500

LANDSCAPE CONSULTANT:

50
STX LANDSCAPE ARCHITECTS
200

51 BRAS BASAH ROAD


#03-05/06 MANULIFE CENTRE S 189554
50
100

TEL 65 6327 4452


QUANTITY SURVEYOR:
Detail 1 Detail 2 RIDER LEVETT BUCKNALL LLP
RIGHT SIDE VIEW
500

LEFT SIDE VIEW


1850

2350

NTS NTS 150 BEACH ROAD


700

SINGAPORE 189720
TEL 65 6339 1500
LAN

PROJECT TITLE:
EP
2900

2400

2400
100

2800

PROPOSED INTEGRATED DEVELOPMENT CONSISTING OF BUS INTERCHANGE,


SE

FOOD CENTRE, HERITAGE WALK AND PUBLIC HOUSING DEVELOPMENT


40
2610
50

ILS

COMPRISING 3 BLOCKS OF 13 STOREY RESIDENTIAL BUILDING (TOTAL 330 UNITS)


WITH 1 BLOCK OF MULTI-STOREY CAR PARK, ESS, PRECINCT PAVILION AND
15 120 15
TA

SOCIAL COMMUNITY FACILITIES AT UPPER SERANGOON ROAD (BIDADARI C5)


2335

DE

EXTERIOR INTERIOR MK24 ON LOT09727V PT, 09720KPT UPPER SERANGOON ROAD


500

(TOAPAYOH PLANNING AREA)


500

50 MAIN CONTRACTOR:

15
F.F.L. HHS INTERIOR F.F.L. CHINA CONSTRUCTION(SP)

65
100

DEVELOPMENT CO PTE LTD

50

15
10 HOE CHIANG ROAD # 27-02
200

S.F.L. KEPPEL TOWER, SINGAPORE 089315

Detail 4
TEL: 6227 4537 FAX: 6227 5073
500

500

TYPE BLOCK LEVEL NO.

1200 50 DETAIL 2 NTS 201A


2ND
3RD
1
- PRECASTER:
4TH -
5TH -
600

550

PHS13a-9002x
Detail 3
3RD -
50

50 150 50

201B 4TH -
33 KAKI BUKIT ROAD 6 SINGAPORE 415803
300

300

5TH -
TEL: +(65) 6100 1188 FAX: +(65) 6288 3688
250

LEGEND: 3RD -
150

NTS
201C 4TH -
15

5TH - DRAWING TITLE:


FRONT VIEW SFL RS - ROUGHENED SURFACE TOTAL NO. 1
CP - CHEQUERED PLATE FINISH
175 200 1125 200
RE - RECRESS FOR HANDIAL
QUANTITY: 1 PHS13a-9002x-A
300 1100 300
100 OD - OVERALL DIMENSION AREA: 1.37 m²
300 500 500 300 PART 1 OF 2
PL - PANEL DIMENSION CONCRETE VOLUME: 3.24 m³ DATE: DRAWN: CHECKED: APPROVED:
Top View Front View CG - CENTER OF GRAVITY
FI - FIXTURE CONCRETE GRADE: C40
27/6/2019 HST YXQ GP
SCALE: DRAWING NAME: SHEET NO. REV.
PANEL WT (TON): 8.45 1:15 SEF_BDDRC5_PHS13a-9002xA-7 1 3
2 50H10

Reinf. schedule, bending shapes 1700


SHOP DRAWING REVIEW
Mark Pcs ø Individ. Dim. bending shape Total Mass 250 1200 250 ARCHITECT:
length (not to scale) length
H13-330 18
H28 21 21 H28 MKPL ARCHITECTS PTE LTD
[mm] [m] [m] [kg]
150 150 CECIL STREET
21 H28 3RD S.F.L. 7 H10 VENT SLEEVE #12-00 SINGAPORE 069543
1 107 8 0.40 42.80 16.91
4 6 7 1 H10-100 4 TEL 65 6223 4633 FAX 65 6223 4233
1 2

80
Review for Conformance with project design concept. This review does not in any way relieve contractor

175

175
H28 21

150

250
220
80
from responsibility for correctness of dimension, quantities, calculation, construction, fabrication
45
techniques and co-ordination of work of other trades Non-conformities and errors detected are noted.

35
2 50 10 1.13 190 56.25 34.71
75
REVIEW COMPLETED

50
2 4

60
1
175

150
RECEIVED FOR INFO ONLY
H10-100 13
410

50

5H10(17)-100
800
190
RESUBMIT
3 3 10 1.05 3.15 1.94 125

150
MAKE CORRECTIONS NOTED
200
100

135
90
170
H10-100 2 REJECTED
190

SIGN : _______________ DATE: _______________


90

4 3 10 0.97 2.93 1.80


190
7 6 STRUCTURAL AND CIVIL ENGINEER:
H10 11
2
KTP CONSULTANTS PTE LTD

50
460

5 4 10 1.50 6.00 3.70


9 H10
190

3791 JALAN BUKIT MERAH


#05-18 E-CENTRE @ REDHILL 159471
90

19 H16 TEL 65 6273 5622 FAX 65 6273 8454


350

SH
SH
6 4 10 0.85 3.40 2.10 This check is made to review the general confromance on the design intention only, as this
150

2 H10-100

OR ME
is a Design & Build Development. This does not relieve the contractor and Sub-Contractor

R ME
Vent sleeve 1

700
of his contractual obligation and responsibilities to ensure the adequacy, integrity, suitability
and practicality of the proposed detail design and that it is fit for its intended purpose and in
14 H10-100

N FO
accordance with the Employer's Requirements; and to confirm and correlate dimensions on

PLAN F
7 12 10 0.85 850 10.20 6.29 site, select fabrications process and techniques of construction, coordinate his work with all
other trades and execute his works in accordance with the best standard practice and

2800

2800
P LA
2400

2900
Local Building Regulations as well as the approved plans.

2610

2610

2610
APPROVED REVISE & RESUBMIT COMMENTS ON STRUCT'L.
7 H10

SEE
A A

S SEE
H10-100 2 ASPECTS ONLY
H10 11 VENT SLEEVE

50
8 4 10 1.00 4.00 2.47
440

APPROVED REJECTED NO COMMENT

AILS
545
5 3 H10-100 13 WITH COMMENTS

DETAIL
DE T
NAME & SIGNATURE : _______________ DATE: _______________
9 1 10 1.20 1180
1.20 0.74 H10 16
8 H10 MECHANICAL & ELECTRICAL ENGINEER:
H10-100 2
ALPHA CONSULTING ENGINEERS PTE LTD
10 2 10 1.25 2.50 1.54
2 2 BUKIT MERAH CENTRAL
125
220

#16-00 SPRNG SINGAPORE 159835


1030
B B H10-100 14 TEL 65 6276 2228 FAX 65 6276 9929

1300
Review of this shop drawing / submitted is only to check for
11 4 10 2.58 10.30 6.36
20 H16 general conformance with the specifications and drawings.
2560

Comments / corrections made do not relieve the Contractor/


435
Sub-Contractor of his contractual responsibility and from
50

235

12 6 13 1.60 9.60 10 compliance with requirements of the Contract Documents.


2 C H16 19
190

660
4 8 The Contractor / Sub-Contractor remains responsible for
the correctness of quantities and dimensions, selection of
13 26 10 1.30 33.80 20.85 Vent sleeve 2 materials / equipment, fabrication processess, methods
190

150

250
of installation, coordination of work with all other trades

15

15

15
2ND S.F.L.
495
50

745

4 5 3 8 1 2 and the safe and satisfactory performance of the work.


50

14 24 10 1.80 43.20 26.65 H28 21 21 H28 12 6H13-80 NO EXCEPTION TAKEN REVISE - NO RESUBMISSION REQ'D.
C
190

REVISE AND RESUBMIT SUBMIT SPECIFIED ITEM REJECTED


315

Plan showing rebar


50

REVIEWED BY : _______________ SIGN : ____________


Left view showing rebar
40

440

15 2 10 1.83 3.65 2.25


150

DATE RECEIVED :________ DATE RETURNED : __________


745
50

70

16 2 10 1.15 2.30 1.42


50
50

150

350 185
60

0
16

3RD S.F.L. 3RD S.F.L.


80
50

150

17 10 10 1.40 1400 14 10.37


175

4 3H10-100
35

35

35

35
550
5 3H10-100
H8 1 H8 1 H8 1
140

18 8 13 1.28 105 10.20 10.63 1 3H8-100 1 3H8-100


75

215
240

6H8-100(V)

6H8-100(V)

6H8-100(V)
205 3 10/1/19 HST REV. BASED ON KTP

@ RIB ONLY

@ RIB ONLY

@ RIB ONLY
COMMENT
6 3H10-100
610

610
19 2 16 1.83 3.65 5.76
2 20/12/18 HST GENERAL REVISION
1800

HST REV. BASED ON ALPHA


3 3H10-100 1 20/11/18 COMMENT
400

20 1 16 2.18 2.18 3.43 REV DATE NAME SUBJECT


1500

DEVELOPER:

21 4 28 2.50 2500 10.00 48.34


HOUSING & DEVELOPMENT BOARD
512 BISHAN STREET 13
#02-524 SINGAPORE 570512

H8 1 H8 1 H8 1

H8-600(V)

H8-600(V)

H8-600(V)
@ RIB ONLY

@ RIB ONLY

@ RIB ONLY
Total weight [kg] : 214.18 LANDSCAPE CONSULTANT:
2800

HOUSEHOLD SHELTER

HOUSEHOLD SHELTER

HOUSEHOLD SHELTER

HOUSEHOLD SHELTER

HOUSEHOLD SHELTER
STX LANDSCAPE ARCHITECTS
2610

2610

2610

2610

2610

2610
Mesh Schedule 51 BRAS BASAH ROAD
EXTERNAL

EXTERNAL

EXTERNAL

EXTERNAL

EXTERNAL
#03-05/06 MANULIFE CENTRE S 189554
Mark no Pcs Mesh identifier Bending Shape Length Mass TEL 65 6327 4452
1900

1900

QUANTITY SURVEYOR:
RIDER LEVETT BUCKNALL LLP
[m] [kg]
710

1 1 WD10 2.43 74.98


50

150 BEACH ROAD


200

H8 1 H8 1 SINGAPORE 189720
50

1400

TEL 65 6339 1500


200
800

2 2 WD10 3.70 228.81 H8 1

6H8-100(V)

6H8-100(V)

6H8-100(V)
50

PROJECT TITLE:
2600

@ RIB ONLY

@ RIB ONLY

@ RIB ONLY
PROPOSED INTEGRATED DEVELOPMENT CONSISTING OF BUS INTERCHANGE,
FOOD CENTRE, HERITAGE WALK AND PUBLIC HOUSING DEVELOPMENT
50

485 COMPRISING 3 BLOCKS OF 13 STOREY RESIDENTIAL BUILDING (TOTAL 330 UNITS)


50

WITH 1 BLOCK OF MULTI-STOREY CAR PARK, ESS, PRECINCT PAVILION AND


1200

3 1 WD10 1.80 55.66 SOCIAL COMMUNITY FACILITIES AT UPPER SERANGOON ROAD (BIDADARI C5)
MK24 ON LOT09727V PT, 09720KPT UPPER SERANGOON ROAD
(TOAPAYOH PLANNING AREA)
50

4 2 WD10
740

2.45 151.51
MAIN CONTRACTOR:
150

150

150
50

5050

5050

CHINA CONSTRUCTION(SP)
200

15

15

15

15

15

15
50

1400

410
2ND S.F.L. 250 250 50 200 50 200 50 200 2ND S.F.L. DEVELOPMENT CO PTE LTD
50

5 1 WD10 1.73 53.34


250 250 250 10 HOE CHIANG ROAD # 27-02
1200

H16 20 19 H16 H16 20 19 H16


KEPPEL TOWER, SINGAPORE 089315
Section 1-1 Section 2-2 Section A-A Section B-B Section C-C
50

TYPE BLOCK LEVEL NO. TEL: 6227 4537 FAX: 6227 5073
50

WD10 2ND 1
6 1 1.48 45.61
3RD - PRECASTER:
700

201A
4TH -
660
5TH -
50

50 PHS13a-9002x 3RD -
201B 4TH -
7 1 WD10 1.23 37.88
5TH - 33 KAKI BUKIT ROAD 6 SINGAPORE 415803
LEGEND: 3RD - TEL: +(65) 6100 1188 FAX: +(65) 6288 3688
700

201C 4TH -
50

420

1400
5TH - DRAWING TITLE:
8 1 WD10 2.45 75.76 RS - ROUGHENED SURFACE TOTAL NO. 1
50

200

CP - CHEQUERED PLATE FINISH PHS13a-9002x-A


50

750

QUANTITY: 1
RE - RECRESS FOR HANDIAL
OD - OVERALL DIMENSION AREA: 1.37 m²
PART 2 OF 2
Total weight [kg] : 723.55 PL - PANEL DIMENSION CONCRETE VOLUME: 3.24 m³ DATE: DRAWN: CHECKED: APPROVED:
CG - CENTER OF GRAVITY
27/06/2019 HST YXQ GP
CONCRETE GRADE: C40
FI - FIXTURE
SCALE: DRAWING NAME: SHEET NO. REV.
PANEL WT (TON): 8.45 1:15 SEF_BDDRC5_PHS13a-9002xA-8 2 3