Professional Documents
Culture Documents
Cooling of Cream PDF
Cooling of Cream PDF
=i Éëëç å=VK=` l l i fk d =l c =` o b ^ j
Lesson 9
COOLING OF CREAM
9.1 Introduction
The primary purpose of cooling of cream is to minimize the growth of microorganisms and
bring about the desired fat crystallization required in butter making. With the advent of
more efficient heat exchangers, plate cooling of cream is common. Relatively higher
viscosity of cream as compared to milk necessitates particular attention in the design of
plate heat exchanger.
Cooling of cream can be accomplished by using tank type batch cooler or surface cooler,
when the scale of operation is small as in case of farm cream production. For industrial
purposes, surface coolers can be used but plate coolers and tubular coolers are commonly
used. For small quantities of cream, use of ice water makes it possible to achieve rapid
cooling to a sufficiently low temperature.
It is economical to provide a simple cream cooling tank, preferably insulated, in which the
cream can is immersed in cool water. The ideal cream cooling tank is large enough to hold,
sufficient body of water to avoid rapid warming up. It is sufficiently insulated to hold the
temperature within a few degrees for eight to twelve hours. It is deep enough to allow the
water to cover the cans at least as far up as the cream will reach when the cans are full.
When using a combination of intra-tube heater and surface cooler, the hot cream flows up
through the inside of the pipe unit and the cold cream flows down over the outside of the
pipe unit. The incoming cold cream is thus heated by the hot cream coming from the
pasteurizer, and the out flowing hot cream is cooled by the cold, raw cream flowing to the
pasteurizer. Under average conditions the temperature of the cold cream is thus raised by
about 12-15°C by the hot cream, and the temperature of the hot cream is lowered
approximately 12-15°C by the cold cream, thus accomplishing a considerable saving of
heat energy.
Under average plant operating conditions, the surface cooler appears highly suitable for the
cooling of flash-pasteurized cream. Surface cooler comprises two corrugated/undulated SS
plates providing horizontal passages for cooling water or liquid refrigerant between the
plates. The cream allowed to flow from top reservoir over the outside of the plates gets
cooled. In order to avoid inconvenient height for operation and cleaning, the surface cooler
is usually confined to two sections, each arranged with independent in-take and out-flow
for the refrigerant. The upper section is cooled with water and lower section with brine or
direct expansion ammonia.
The surface cooler has the added advantages of aerating the cream. This is especially
desirable where steam jet pasteurization is practiced for the purpose of volatilizing
objectionable flavors, thus facilitating escape of the volatilized products from the cream
that is flowing in a thin film over the outside of the surface cooler. The surface cooler also
permits some evaporation of moisture, which is desirable in the case of cream that has
suffered dilution with steam condensate, as the result of steam injection pasteurization.
One of the drawbacks of the surface cooler is that, it “breaks” the closed system of the
cream flow. Unless the cooler can be installed at an elevation high enough to permit the
cooled cream to flow into the cream vat by gravity, an additional pump is necessary. In
addition, the higher its elevation, the less accessible are its upper portions for proper
cleaning. The cabinet surface cooler eliminates the drawbacks of excessive height. This
type of surface cooler consists of multiples of cooling tube section, arranged on the same
level, instead of one on top of the other as represented by the old line surface cooler. The
cabinet cooler has distinct advantages over the open surface cooler.
The internal tube cooler consists of the two-tube principles, one inside of the other. The
cream flows through the inner tube, while the refrigerant flows in counter current between
ÉÅç ì êëÉëKåÇêáKêÉëKáåLã ç ç ÇäÉLã ç ÇLêÉëç ì êÅÉLî áÉï KéÜé\ áÇZOMMT OLP
QLTLNP a q JOW
=i Éëëç å=VK=` l l i fk d =l c =` o b ^ j
the inner and outer tubes. The usual unit consists of one or two sections for water and one
section for brine or direct expansion ammonia.
This type of cooler has the advantage of preserving the “unbroken,” closed system of
cream flow, discharging the cream into the vats and up to any reasonable elevation without
the need of a pump at the discharge end of the cooler. The internal tube cooler does not
subject the cream to aeration. If aeration is desired it should be provided before the cream
reaches this cooler.
In the case of sour, neutralized cream, the internal tube cooler usually does not permit of
cooling to a temperature much below 15.5°C without danger of the formation of a cream
plug and of clogging. This tendency is especially prevalent when such cream has received
severe prior treatment, such as, for instance, in connection with prolonged vacuum for
removal of obnoxious flavors and odors. It is to refrain from attempting to cool such cream
to churning temperature (below 15.5°C) in this cooler, and to finish the cooling to the final
low temperature in the coil vat.
Forcing the cream through several standard sections of internal tube cooler, subjects it to
considerable pressure, which further aggravates the tendency of cream in which the
emulsion coefficient has already been lowered to near the” breaking” point, to churn either
in the cooler or in the vat, causing delay and extra labor, and often costly loss of fat.
DT-2