You are on page 1of 7

FARO ® Laser Scanner Focus 3D X 30

with HYPERMODULATIONTM

Quick Start Guide


General information

SCENE Software
Standard Equipment
SCENE is specifically designed for all FARO laser scan-
ners. The software processes and manages scanned
data both efficiently and easily by using the auto-
1
1. Scanner transport and carry
case matic object recognition and scan registration.

SCENE is an extremely user-friendly software that


2. AC power cable allows scans to be automatically combined. The
1 2 resulting point cloud can be viewed in three dimen-
7 sions. All the scans are available in color and as
3. External power supply unit with high-contrast intensity images.
8 3 cable
• Automated target-less scan registration
• SCENE WebShare Cloud integration
4. PowerBlock battery • Super-crisp visualisation
4 • Easy processing of large scan projects
• Plug-Ins for extended functionality
6 5 5. Memory card case • Homogenisation of point clouds
10 5
4
6.
6 USB memory card reader Software Options
The Focus 3D X 30 and the SCENE software are com-
9 2 7. Quick Start Guide, situated in patible with the most common CAD software ap-
7 the case lid
3 plications and can be used to export scan data to
over 50 common software solutions.

8
8. DVD with SCENE software and
Focus 3D X 30 user’s manual,
situated in the case lid

9. Laser scanner with inserted SD


9 memory card

10. Panorama Quick Release with


10 tribrach adapter and appropri-
ate screws
FARO Webinars

Hear from industry experts on emerging trends in


The SD memory card, a tripod and
3D documentation, advancements in 3D metrology
the PowerBlock battery or the exter-
and portable CMMs and best practices without
nal power supply unit with AC power
ever leaving the office. If you are unable to attend
cable are the minimum required
any of our live webinars, they are all recorded and
equipment to carry out a scanning
uploaded as podcasts here and are searchable by
project.
broadcast date.
www.faro.com/webinars
Getting Started

Online Tutorials 1. Set up the Tripod


Find more information and helpful tips on the use of Extend and lock all legs of the tripod.
the Focus 3D X 30 and SCENE in the Internet at:
Check that the tripod adjustment arrangements have
http://tutorial.faroeurope.com been locked and that the legs are of even length.
Ensure that the surface is stable, that the tripod’s feet
are secured and that it is firm in its position.

FARO 3D App Center 2. Mount the Scanner onto the Tripod

In the 3D App Center you will find software dedicat- To mount the Focus3D X 30 to a tripod we recommend
ed to the FARO 3D Documentation world. The shop using a quick release (e.g. the Panorama Quick Re-
is devided into two main categories: Stand-alone lease that is part of the Focus3D X 130 standard equip-
apps and plug-in apps: ment). The quick release must be equipped with a
http://3d-app-center.faro.com 3/8” screw to fit into the scanner’s mount.
Remove the scanner from the transport case.
Attach the upper part of the quick release to the
scanner’s mount. Make sure to tighten the screw(s).

SCENE WebShare Cloud Mount the counter piece of the quick release onto
the tripod. Make sure that it is fixed securely.

With SCENE WebShare Cloud, FARO offers a com- Carefully mount the Focus3D X 30 with the upper part
prehensive service to provide users with simple of the quick release to its counter piece and lock its
access to 3D documentation. Neither technical fastener. Test that the scanner is correctly locked in
training nor specialist skills in 3D laser scanning are place by gently attempting to lift it from the tripod.
necessary to work with the intuitive user interface.
If applicable, remove the ruggedized aluminium
protection cover from the scanner.
Digital data, such as 3D documentation, often has
to be available to many different project partners.
Previously, users having their own internet server,
could use SCENE WebShare to present their laser
scan projects to clients and project partners. Now
FARO goes considerably further, offering the SCENE
3. Insert the SD Memory Card
WebShare Cloud solution, a hosting service with
various packages at different prices. Insert the SD card with the notched edge in the di-
rection as illustrated until it clicks. The SD card might
• Easy data sharing and collaboration have a protective lock-switch at the top left. Make
• Minimal set up and maintenance effort sure that this lock-switch is in the open position to
• Best possible security level allow the SD card to be written.
• Persistent measurements & annotations
• Hosting service offered by FARO
Do not remove the SD card from the scanner
• Support for mobile devices ! while it is busy, otherwise you risk
Check it out on our demo server at: corrupting data. A busy SD card
is indicated by this icon blinking in
www.websharecloud.com the status bar on the display.
4. Supply Power to the Scanner 5. Switch the Scanner On

The laser scanner can be operated with the battery Press the On/Off button. The scanner LEDs will
or the external power supply unit. blink in blue.
When the scanner is ready, the LEDs stop blink-
Supply Power Using the Battery ing and illuminate permanently blue; the Home
screen of the controller software appears on the
Open the laser scanner’s battery compartment.
integrated touch screen.
With its type label directed upwards, point the
battery contacts to the scanner, push the battery
straight in, and slide it into the compartment until the
fastener clicks into position.
Close the battery cover.
6. Set the Scanning Parameters
Adhere to the battery safety measures de-
! scribed in the laser scanner manual. Insert
The scanning parameters are the settings used
by the Focus 3D X 30 for recording the scan data.
or remove batteries from the laser scanner
in dry and dust-free environments only. There are two ways to set the scanning parameters:
• select a scan profile which is a predefined
set of scanning parameters.
• or change the parameters individually.
Supply Power with the External Unit
Push the Parameters button on the Home screen.
Use a cable strap to attach the power supply unit to
the tripod. This will help prevent damage to the cable Selecting a Scan Profile
connector. Wrap the strap around the power supply
unit. Insert the small end into the slot and pull togeth-
Push the Selected Profile button to select
er. Attach the power supply to the tripod. 1 one of the predefined scan profiles.
Connect the cable of the power supply unit to the
power socket of the laser scanner. Use the end with You will get a list of all available profiles.
the 90° bend connector. Confirm the direction of the
power supply’s plug. If you forcibly insert the plug in
a wrong direction, the plug and the scanner can be
Select a profile from the list. The selected
damaged. 2 profile will be highlighted and marked with
Check the input voltage on the type label before a check mark.
connecting. Connect the AC power cable to the
The scanning parameters will be changed
power supply unit and to a power outlet. The upper
according to the settings of the selected
LEDs on both sides of the laser scanner as well as the
profile. To see details of the selected profile,
LED of the scanner mount start illuminating in blue.
push its button once again.

!
To avoid electrical shock, do not use the 3 You may go back to the scanning pa-
external power supply unit outdoors. Use it rameters to change them individually.
in dry indoor environments only.
Setting the Parameters Individually 7. Start a Scan

Please respect all necessary safety measures


Resolution and Quality: push to adjust the and start the scan either by clicking on the Start
ü scan resolution and quality. Resolution is Scan button on the display or by pressing the
the resulting scan resolution in Mega- Start / Stop button on the scanner.
points. The quality setting affects the scan
quality and the scanning time at constant Scanning starts and the laser will be switched
scan resolutions. Increasing the quality on. The scanner will save the scanned data to
reduces noise in the scan data but in- the SD card. The scanner’s LEDs will blink in red
creases scanning time. as long as the laser of the scanner is switched
Scan Range: change the scan area with on. During scanning, the scanner rotates clock-
its horizontal and vertical start and end wise by 180°. If scanning with color, the scanner
angles. continues to turn to 360° to take the pictures.

Select Sensors: enable or disable the


automatic use of the data of the built-in
sensors, (compass, dual axis compensator Remember that the scanner is turning and
(inclinometer) and altimeter). Their infor-
! the mirror unit is rotating with high speed.
mation might be very valuable for the Ensure that the scanner can move freely and
later scan registration in SCENE. that no objects or fingers can touch the
mirror unit.
Scan Duration, Scan File Size: expected
scan time and scan file size in Megabytes.
Please note that the values shown here
are approximate values. You can abort scanning with the Stop Scan
button on the display or with the Start / Stop
Scan Size [Pt]: the resolution of the scan in button on the scanner.
horizontal and vertical points.
Advanced Settings: change the scan filter The scanner might make another full turn to
settings and enable or disable the Far capture inclination data. Please do not move
Distance Optimization. the scanner while this data is being recorded.

When finished, a preview picture of the captured


scan will be displayed on the screen.

To view and process the scanned data with


SCENE, remove the SD card from the scanner,
insert it into your PC, start SCENE and transfer the
scans to your local hard drive. Now, you can
For more information on the scanning view and process the scans with SCENE. For more
i parameters read the Focus 3D X 30 information on this, read the SCENE manual or
manual or view the onscreen help that visit: http://tutorial.faroeurope.com
can be accessed via the help button on
the scanner’s display.
Notes

8. Power the Scanner Off

To shut down the scanner, press its On/Off button


or push the Shut Down button in the controller
software under Manage. All LEDs will start blink-
ing in blue and will stop blinking once the scan-
ner has finished shutting down.

When the scanner has completely shut down,


disconnect the AC power cable first, then dis-
connect the power supply cable from the scan-
ner, remove the battery and secure the equip-
ment in protective cases.

To prevent damages to the scanner, do not


! disconnect the power supply and do not
remove the battery before the scanner has
finished shutting down.

Customer Service

United States and Canada


On the phone: Our customer service staff is
available from 8:00 am to 7:00 pm (EST) from
Monday to Friday.
Toll Free: 1-800-736-2771
E-Mail: support@faro.com

Europe
On the phone: Our customer service staff is
available from 8am to 5pm (CET) from Monday
to Friday.
Free call number: 00 800 3276 7378
E-Mail: support@faroeurope.com

Asia
On the phone: Our customer service staff is
available from 8:30am to 5:30pm (SST) from
Monday to Friday.
Free call number: 1800 511 1360
E-Mail: supportap@faro.com

Online-Support Center: www.faro.com/support


FARO Offices

FARO Technologies Inc. FARO Europe GmbH & Co.KG FARO Singapore Pte. Ltd.
250 Technology Park Lingwiesenstraße 11/2 No. 3 Changi South Street 2
Lake Mary, FL 32746, D-70825 Korntal-Münchingen #01-01 Xilin Districentre Building B
USA Germany Singapore 486548
info@faro.com info@faroeurope.com asia@faro.com

www.faro.com/focus

© 2014 FARO Internal Control File Location:


Revised: February 19th, 2014 \Control\Records\05manufa\PARTSPEC\0_V7\02_Documentation\E1176_FARO_Laser_Scanner_Focus3DX_130_Quick_Start_Guide_EN.pdf

You might also like