Professional Documents
Culture Documents
After you clear main issue for above reasons then you can go to Parameter optimization to reduce drop call rate.
Here are recommended Parameter to reduce call drop rate in 3G UMTS/WCDMA for Huawei Network. If you work
for other Vendor you can refer to your document and looking for same Parameter.
1. Increase HOASUTMR
HOASUTMR meaning HO active set update response timer, A timer to RNC wait for the response to
active set update in soft handover procedure. You can improve call drop in 3G by increase this parameter.
2. Increase Parameter 2D/2F
The idea of this parameter setting is to make fast Handover to GSM network. You can increase 2D/2F parameter and
improve your drop call in 3G by moving traffic to GSM network.
- INTERRATCSTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for CS domain services
Value range: -24~0
Physical unit: dB
Content: For CS domain services, when Ec/No is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -12
- INTERRATCSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for CS domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -100
- INTERRATCSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for CS domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for inter-RAT measurement, the
RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -97
- INTERRATHTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -15
- INTERRATR99PSTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -15
- INTERRATHTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATR99PSTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATHTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS domain HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the
UE reports the event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -110
- INTERRATR99PSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for inter-RAT measurement,
the RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports the
event 2D when the measured value is smaller than the value of this parameter.
Recommended value (default value): -110
- INTERRATHTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for inter-RAT
measurement, the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the
UE reports the event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -107
- INTERRATR99PSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for inter-RAT measurement,
the RNC sends the signaling to deactivate compressed mode and stop inter-RAT measurement, if the UE reports the
event 2F when the measured value is larger than the value of this parameter.
Recommended value (default value): -107