1 Name plate

Graph 1-1 Nameplate

Graph 1-2 product models

- 02 -
DLB1 Catalogue

2 Product series

Rated output power Rated input current Rated output current


Inverter model
(kW) (A) (A)

Single Phase input: AC 220V, 50/60Hz

DLB1-0D40S2G 0.4 5.9 2.5

DLB1-0D75S2G 0.75 8.3 4

DLB1-01D5S2G 1.5 14.1 7

DLB1-02D2S2G 2.2 24.2 10

Three phase input: AC 220V, 50/60Hz

DLB1-0D40T2G 0.4 4.1 2.5

DLB1-0D75T2G 0.75 5.3 4

DLB1-01D5T2G 1.5 8.0 7

DLB1-02D2T2G 2.2 11.8 10

DLB1-0004T2G 4.0 18.1 16

DLB1-05D5T2G 5.5 21.0 20

DLB1-07D5T2G 7.5 33.1 30

DLB1-0011T2G 11 43.8 42

DLB1-0015T2G 15 57.4 55

DLB1-0018T2G 18 71.6 70

DLB1-0022T2G 22 81.7 80

DLB1-0030T2G 30 112.1 110

DLB1-0037T2G 37 137.4 130

DLB1-0045T2G 45 165.3 160

DLB1-0055T2G 55 205.8 210

Three phase input: AC 380V, 50/60Hz

DLB1-0D75T4G 0.75 4.3 2.5

DLB1-01D5T4G 1.5 5.2 3.7

DLB1-02D2T4G 2.2 6.0 5

DLB1-0004T4G 4.0 10.5 8.5

DLB1-05D5T4G 5.5 15.5 13

- 03 -
DLB1 Catalogue

Rated output power Rated input current Rated output current


Inverter model
(kW) (A) (A)

DLB1-07D5T4G 7.5 20.5 16

DLB1-0011T4G 11 27.6 25

DLB1-0015T4G 15 37.1 32

DLB1-0018T4G 18 41.9 38

DLB1-0022T4G 22 49.3 45

DLB1-0030T4G 30 65.7 60

DLB1-0037T4G 37 80.6 75

DLB1-0045T4G 45 96.4 90

DLB1-0055T4G 55 117.6 110

DLB1-0075T4G 75 166.4 150

DLB1-0093T4G 90 184.3 170

Three phase input: AC 460V, 50/60Hz

DLB1-0D75T7G 0.75 4.1 2.5

DLB1-01D5T7G 1.5 4.9 3.7

DLB1-02D2T7G 2.2 5.7 5

DLB1-0004T7G 4.0 9.4 8

DLB1-05D5T7G 5.5 12.5 11

DLB1-07D5T7G 7.5 18.3 15

DLB1-0011T7G 11 23.1 22

DLB1-0015T7G 15 29.8 27

DLB1-0018T7G 18 35.7 34

DLB1-0022T7G 22 41.7 40

DLB1-0030T7G 30 57.4 55

DLB1-0037T7G 37 66.5 65

DLB1-0045T7G 45 81.7 80

DLB1-0055T7G 55 101.9 100

DLB1-0075T7G 75 137.4 130

DLB1-0093T7G 93 151.8 147

- 04 -
DLB1 Catalogue

3 Technical standards

Specifications
Control system Performance and function highly integrated Current Vector General Purpose Inverter.
Drive performance Induction motor and Synchronous motor.
Maximum frequency Vector control: 0~300Hz; V/F control: 0~3200Hz.
Wave-carrier frequency 0.5kHz~16kHz; Depending on load, can automatically adjust wave-carrier frequency.
Input frequency resolution digital setting: 0.01Hz; analog setting: maximum frequency×0.025%.
Open vector control(SVC);
control mode Closed loop vector control(FVC);
V/F control.
G type: 0.5Hz/150%(SVC); 0Hz/180%(FVC).
Starting torque
P type: 0.5Hz/100%.
Speed range 1: 100(SVC) 1: 1000(FVC)
Speed stability accuracy ±0.5%(SVC) ±0.02%(FVC)
Torque control accuracy ±5%(FVC)
G type: 150%rated current60s; 180%rated current3s;
Overload capacity
P type: 120%rated current60s; 150%rated current3s.
Torque boost Automatic or manual 0.1%~30.0%,
Basic functions

· Straight-line V/F curve


· Multi-point V/F curve
V/F curve
· N-power V/F curve (1.2-power, 1.4-power, 1.6-power,
· 1.8-power, 2-power square)
V/F separation Two types: complete separation; half separation. AVR output.
· Straight-line ramp
· S-curve ramp
Ramp mode
Four groups of acceleration/deceleration time with the
range of 0.0–6500.0s
DC braking frequency: 0.00 Hz to maximum frequency
DC braking Braking time: 0.0–36.0s
Braking action current value: 0.0%–100.0%
JOG frequency range: 0.00–50.00 Hz
JOG control
JOG acceleration/deceleration time: 0.0–6500.0s
Easy PLC, multiple speeds Up to 16 speeds via the simple PLC function or combination of DI terminal states
Onboard PID Process-controlled closed loop control system
Auto voltage regulation (AVR) Keep constant output voltage automatically when grid voltage fluctuates.
Overvoltage/ Overcurrent stall control The current and voltage are limited automatically during the running process so as to
avoid frequent tripping due to overvoltage/overcurrent.
Fast current limit function Protect inverter from overcurrent malfunctions.
It can limit the torque automatically and prevent frequent over current tripping during
Torque limit and control
the running process. Torque control can be implemented in the FVC mode.

- 05 -
DLB1 Catalogue

Power dip ride through The load feedback energy compensates the voltage reduction so that the Invertercan
continue to run for a short time.
Special Functons

Timing control Time range: 0.0–6500.0 minutes


Two-motor switchover Two motors can be switched over via two groups of motor parameters.
Fieldbus Supports RS485, Profibus-DP, CANlink, CANopen (need extention cards)
Background software Change inverter parameter & vitual oscillograph to monitor inverter status.
· Operation panel
· Control terminals
Command source
· Serial communication port
You can perform switchover between these sources in various ways.
11 frequency sources, such as digital setting, analog voltage setting, analog current
Frequency source setting, pulse setting and serial communication port setting. You can perform
switchover between these sources in various ways.
Operations

Auxiliary frequency source 11 auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and
frequency synthesis.
6 digital input (DI) terminals, DI5 supports up to 100 kHz high-speed pulse input;
Input terminal 3 analog input (AI) terminals, support 0–10 V voltage input or 4–20 mA current
input
2 digital output (DO) terminal (FM supports 0–10 kHz square wave signal output)
1 relay output terminal
Output terminal
2 analog output (AO) terminal that support 0–20 mA current output or 0–10 V
voltage.
LED display Displays parameters.
Display and panel

It can lock the keys partially or completely and define the function range of some keys
Key lock
so as to prevent mis-function.
Motor short-circuit detection at power-on, input/output phase loss protection,
Protection function overcurrent protection, overvoltage protection, undervoltage protection, overheat
protection and overload protection
Optional parts PG card, brake unit, RS485 card, CAN card, Profibus-DP card
Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke,
Location
vapour, drip or salt.
Altitude Lower than 1000m.
Environment

-10° C to +40° C (de-rated if the ambient temperature is between 40° C and


Ambient temperature
50° C)
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9m/s2 (0.6g).
Storage temperature - 20℃ ~ + 60℃ .

- 06 -
DLB1 Catalogue

4 Product outline

Graph 2-3 400W ~ 3.7KW product outline & dimensions

Graph 2-4 5.5 ~ 7.5KW product outline & dimensions

- 07 -
DLB1 Catalogue

Graph 2-5 11 ~ 55KW product outline & dimensions

- 08 -
DLB1 Catalogue

5 Installation dimensions
Input voltage 380V

(mm) Outline dimensions (mm)


Weight
Inverter model (mm)
(kg)
A B H H1 W D

DLB1-0D40-T4G
DLB1-0D75-T4P

DLB1-0D75-T4G
DLB1-01D1-T4P

DLB1-01D1-T4G
DLB1-01D5-T4P
114 177 190 190 127 168 φ5.5
DLB1-01D5-T4G
DLB1-02D2-T4P

DLB1-02D2-T4G
DLB1-03D7-T4P

DLB1-03D7-T4G

DLB1-05D5-T4P

DLB1-05D5-T4G
142 232 245 245 155 172 φ5.5
DLB1-07D5-T4P

DLB1-07D5-T4G

DLB1-0011-T4P

DLB1-0011-T4G
130 384 350 400 202 184 φ6
DLB1-0015-T4P

DLB1-0015-T4G
DLB1-0018-T4P

DLB1-0018-T4G
150 409 375 425 226 184 φ6
DLB1-0022-T4P

DLB1-0022-T4G
DLB1-0030-T4P
160 484 450 500 260 222 φ7
DLB1-0030-T4G
DLB1-0037-T4P

DLB1-0037-T4G
DLB1-0045-T4P
180 570 540 590 270 267 φ10
DLB1-0045-T4G
DLB1-0055-T4P

DLB1-0055-T4G
180 590 560 610 280 282 φ10
DLB1-0075-T4P
DLB1-0075-T4G
DLB1-0093-T4P 240 720 680 740 340 333 φ10
DLB1-0093-T4G

-9-
DLB1 Catalogue

Input voltage 660V

(mm) Outline dimensions (mm)


Weight
Inverter model (mm)
(kg)
A B H H1 W D

DLB1-0018-T7G
DLB1-0022-T7P

DLB1-0022-T7G
DLB1-0030-T7P
180 540 520 560 320 240 φ7 37
DLB1-0030-T7G
DLB1-0037-T7P

DLB1-0037-T7G
DLB1-0045-T7P

DLB1-0045-T7G
DLB1-0055-T7P
DLB1-0055-T7G
DLB1-0075-T7P
320 740 710 760 470 315 φ10 69
DLB1-0075-T7G
DLB1-0093-T7P

DLB1-0093-T7G

- 10 -
DLB1 Catalogue

6 Detachable keyboard(operation panel) dimensions

Graph 2-6 detachable keyboard outline dimensions

Graph 2-7 detachable keyboard aperture dimensions

- 11 -
DLB1 Catalogue

7 Standard wiring diagrams

Graph 2-8 0.4~18.5KW inverter wiring diagram

- 12 -
DLB1 Catalogue

Graph 2-9 22 ~ 93KW inverter wiring diagram

- 13 -